1. Y Y lt e Model 1200 Le Chassis Interconnect LLI Module User Manual 0 d N gt o M Y Y oz O i N pen o z EdgeAccess Universal Chassis System NOTICE This device contains static sensitive components It should be handled only with proper Electrostatic Discharge ESD grounding procedures NOTE Cet quipement contient des composants sensibles aux d charges lectro statiques Il doit absolument tre manipul en respectant les r gles de mise la terre afin de pr venir de telles d charges NOTICE Canoga Perkins has prepared this users manual for use by customers and Canoga Perkins personnel as a guide for the proper installation operation and or maintenance of Canoga Perkins equipment The drawings specifications and information contained in this document are the property of Canoga Perkins and any unauthorized use or disclosure of such drawings specifications and information is prohibited Canoga Perkins reserves the right to change or update the contents of this manual and to change the specifications of its products at any time without prior notification Every effort has been made to keep the information in this document current and accurate as of the date of publication or revision However no guarantee is given or implied that the document is error free or that it is accurate with regard to any specification CANOGA PERKINS CORPORATION 20600
2. 000000 0000000000000 3 1 3 1 The CIM Management Screen neon eee idee tee Pere tee eene teet gen 3 1 3 2 Using Alarm Information 1 2 eee eret eee rette eee bte Maile alee aa 3 2 Chapter 4 CIM SpecificatioNs cmommsssss 4 1 Appendix A Warranty Information A 1 Appendix B CIC A r B 1 List of Figures Figure 1 CIM in the UCS 1002 Chassis iii 1 1 Figure 2 CIM Front Panel jut acere SERE EE IL 1 2 Eigure 3 CIMiManagement Screen eden eq boten ire 3 1 List of Tables Table 1 Front Panel LEDS iei eee ee a Pert eiie e ore ah 2 2 Table 2 CIM Management Status Definitions 3 1 Model 1200 CIM User Manual iii iv EdgeAccess Universal Chassis System Model 1200 CIM User Manual EdgeAccess Universal Chassis System Chapter 1 Introduction 1 1 Overview The Chassis Interconnect Module CIM used in a Universal Chassis System UCS 1000 chassis links up to eight chassis in a domain to provide management and alarm status This domain can include both UCS 1000 and 1002 Link the chassis in a cascade through the Chassis Link Up and Down ports on the front panel Figure 1 shows the CIM in its dedicated slot 0 in the chassis The CIM functions include e Provides status information for the chassis e Collects alarm status through the backplane from other modules in the chassis e Indicates major and minor alarm conditions through LEDs on the front panel e Forwards alarm signals to external devices th
3. CIM Management Status Definitions Field CIM Status CIM clock CIM Providing Clock Definition Shows if this CIM is online or offline shows that another CIM provides the clock signal CIM Interlink Clock Alarm Relay Status chassis Alarm Latch Status Model 1200 CIM User Manual Shows a latched alarm relay Major or Minor in this chassis Lists status for the clock signal on this CIM either good or failed Enabled shows that this CIM provides the clock signal or Disabled Lists status for the clock signal on the link either good or failed Shows an alarm condition Major or Minor in this chassis or a linked 3 1 EdgeAccess Universal Chassis System Field Definition Fan Status Shows current fan condition Good or Failed which indicates that one or more of the four fans failed call customer service Backplane Alarm Inputs Shows fault conditions in a module in this chassis or in a linked CIM CIM Major Alarms Shows detected Major or Minor alarm conditions CIM Minor Alarms Up Link Installed Shows connections to other CIMs Down Link Installed CIM Model Lists configuration data CIM Firmware CIM Serial Number CIM Hardware Version Note If Alarm Relay Status is Major or Minor and Alarm Latch Status is off the alarm condition occurred on a linked chassis 3 2 Using Alarm Information All modules in the chassis route alarms to the CIM In addition the CIM generates alarms for internal faults The CIM forwards
4. Prairie Street Chatsworth California 91311 6008 Business Phone 818 718 6300 Monday through Friday 7 a m 5 p m Pacific Time FAX 818 718 6312 24 hrs Web Site www canoga com Email fiber canoga com Copyright 2000 2005 Canoga Perkins Corporation All Rights Reserved EdgeAccess Universal Chassis System Model 1200 2000 Chassis Interconnect Module User Manual Model Number 1200 UM Part Number 6912251 Rev H 01 2008 To reference Technical Advisories and Product Release Notes go to Canoga Perkins website ii Model 1200 CIM User Manual EdgeAccess Universal Chassis System Table of Contents Chapter 1 Introduction nuit esentndtiosemitieseneredies tiateeelies 1 1 1 1 OVerVIGW xcci eee teet ree ed tec EN a e te v e eb eee LEE ar de dete 1 1 1 2 External Features 22 iet ate He p at e tbt eor Heri Hae Le ani el titi hl 1 2 Chapter 2 Installing the C IML iiie e eere cocco seen iua oo odas ee oops oc aa sete Una paret dn e aea ivvUs 2 1 2 1 Install a EM ocn ler etie te t ot Abe d ee 2 1 2 2 Connect the Cables 5 0333 eri C TU i 2 1 2 3 Front Panel Controls iin eret tear TO 2 2 2 94 MCRD See t tete eth teatro AAT LIE dt dep PLU qe rr o LUN SA TE 2 2 2 3 2 Alarm Acknowledgment Pushbutton RL 2 3 2 4 Clock Source for Linked CIMS o pte obo e Raben 2 3 2 5 Power Up the Chassis citado locos Meiste Sie nets Degas da 2 4 Chapter 3 Management VT 100 22000000000000s000000000220000000 0200000000
5. S 3548 N 55022 N 55024 N 61000 3 2 N 61000 3 3 R amp TTE Directive EN 300 386 NEBS Level 3 CE Mark E E E E Model 1200 CIM User Manual EdgeAccess Universal Chassis System Appendix A Warranty Information Current Warranty information is available on line in the Client Login Area of the Canoga Perkins web site www canoga com or by contacting Technical Support at 800 360 6642 voice or fiber canoga com email Model 1200 CIM User Manual A 1 EdgeAccess Universal Chassis System Appendix B Glossary These definitions apply to the 1200 CIM ALM ACK Alarm Acknowledgement CIM Chassis Interconnect Module CLK Clock COM Common DMM Domain Management Module MAJ Major MIN Minor NO Normally Open NC Normally Closed RMA Return Material Authorization STA Status TB Terminal Block connector UCS Universal Chassis System Model 1200 CIM User Manual B 1 EdgeAccess Universal Chassis System CANOGA PERKINS CANOGA PERKINS CORPORATION 20600 Prairie Street Chatsworth California 91311 6008 USA Phone 818 718 6300 FAX 818 718 6312 Web Site www canoga com Email fiber canoga com Model 1200 CIM User Manual Blank
6. ding the active clock source for the management bus Off This CIM is not the clock source STA Status Green Normal operation Amber This alarm relay is latched with a major and or minor alarm Red Fault in the CIM MAJ Major OFF No major alarms Red A major alarm in the CIM or the chassis MIN Minor OFF No minor alarms Amber A minor alarm in the CIM or the chassis 2 2 Model 1200 CIM User Manual EdgeAccess Universal Chassis System Note When an alarm occurs in a multiple chassis configuration only the chassis that generates the alarm shows the amber STA LED 2 3 2 Alarm Acknowledgment Pushbutton The Alarm Acknowledgement ALM ACK reset pushbutton on the front panel resets the latch for the alarm relay which can reset the external device connected to the alarm relay terminal block ALM ACK does not reset or correct the alarm condition and the LED s will remain on until the problem is resolved See Figure 2 When an alarm occurs in a multiple chassis system look for the chassis with the STA LED lit amber that chassis is generating the alarm Press ALM ACK on that CIM to turn off the external device Check the alarm condition and resolve the problem For more information about alarms see Chapter 3 2 4 Clock Source for Linked CIMs The clock source for the system depends on how the interconnecting chassis are configured Caution To prevent clock errors and ensure proper clocking make sure that the link cables connect the c
7. for the UCS 1000 2 Insert the CIM in the bottom of slot 0 pushing it firmly into the backplane connector Do not force it 3 Hand tighten the captive screws to secure the CIM in the chassis Note The CIM is hot swappable and can be inserted or removed at any time without affecting data transfer in other modules 2 2 Connect the Cables The CIM includes proprietary chassis link ports connecting cables are provided to link multiple chassis together Each CIM package includes a two foot interconnect cable 98800020 to link to another chassis in the same rack through the CIM ports Do not use other cables to link CIMs To link two or more chassis see Figure 2 and follow these steps Caution The total length of all chassis interconnect cables must not exceed 22 feet 1 Plug a cable into the bottom Down port on CIM 1 and into the top Up port on CIM 2 2 Plug another cable into the bottom Down port on CIM 2 and into the top Up port on CIM 3 3 Continue to link additional chassis in the same rack in the same way Note Unused link ports do not require termination For a dual rack configuration use the proprietary ten foot cable 98800021 to link the racks Together the two racks can support up to eight linked chassis 4 Make sure that the chassis are mounted in the rack in numeric order by chassis ID so that the optional Domain Management Module DMM can access each chassis 5 Plug the ten foot cable into the botto
8. hassis in numeric order and Link Down to Link Up e Ina single chassis configuration the CIM provides the primary clock to the management bus If the CIM clock fails the DMM provides a redundant clock to the management bus e Ina multiple chassis configuration the first CIM in the link provides the primary clock to the management bus If the clock fails in the first CIM the next CIM in the link provides a redundant clock to the management bus Model 1200 CIM User Manual 2 3 EdgeAccess Universal Chassis System 2 5 Power Up the Chassis Switch on the power supply s for the chassis The CIM receives power through the backplane During the power on self test all LEDs light amber At the end of self test check for these LED conditions e CLK lights Green if this CIM provides the clock otherwise CLK is Off e STA lights Amber indicates a power cycle and must be reset e MAJ and MIN are off Press ALM ACK to change STA to Green If an alarm condition occurs in this chassis or another linked chassis e Foraminor alarm MIN lights Amber and the Minor alarm contacts are latched e Fora major alarm MAJ lights Red and the Major alarm contacts are latched Note The MAJ or MIN LEDs turn off only when the cause of the alarm is resolved and reset Pressing the ALM ACK switch resets only the alarm relays which can turn off external device s 2 4 Model 1200 CIM User Manual EdgeAccess Universal Chassis System Chapter 3 Manageme
9. m Down port on the CIM with the highest number in the first rack and into the top Up port on the CIM with the next number in the second rack Model 1200 CIM User Manual 2 1 EdgeAccess Universal Chassis System All modules in the chassis supply their alarm status to the alarm relay contacts on the CIM You can connect an external device to the terminal to provide alarm information to a person or an environment away from the chassis 6 Connect devices to collect alarm information for Major and Minor alarms The alarm contacts are located on the front panel see Figure 2 The relay alarm contacts provide both normally open and normally closed contacts for each port e NO The contacts are open for normal operation and closed in a fault condition e COM The electrical common e NC The contacts are closed for normal operation and open in a fault condition 7 If the chassis includes the optional fan tray locate the cable in the front of the fan tray and plug it into the FAN connector on the CIM Table 1 lists pin assignments Table 1 Fan Connector Pins Pin Signal 1 GND 2 48 VDC 3 FAN_IN 4 FAN_GOOD 2 3 Front Panel Controls The front panel of the CIM includes four LEDs that show current status contacts for alarm outputs and an Alarm Acknowledgment pushbutton 2 3 1 LEDs Figure 2 shows the four LEDs on the front panel Table 2 describes them Table 2 Front Panel LEDs LED State Definition CLK Clock Green This CIM is provi
10. nt VT 100 To connect to and manage the CIM use either the serial or Ethernet port on an optional DMM and an application such as HyperTerminal For details about accessing the DMM and using the management software see the User Manual for the 1500 or 1502 Domain Management Module for your system 3 1 The CIM Management Screen If the domain includes an optional DMM you can access the CIM Management screen to view the current status of the chassis The CIM Management screen reports status and alarm conditions that help verify the cause source and current condition of an alarm Figure 3 shows the CIM Management screen and Table 3 describes the fields CIM MANAGEMENT Chassis Type Redundant Power Primary Power Type Primary Power Status Secondary Power Type Secondary Fan Installed Fan Status Up Link Installed Down Link Installed CIM Model CIM Firmware CIM Serial Number CIM Hardware Version Power Status CIM 5U Chassis Yes DC isolated Good DC isolated Good Yes Good No No 1200 2001 39 5 20011195838 EC CIM Status CIM clock CIM Providing Clock CIM Interlink Clock Alarm Relay Alarm Latch Backplane Al CIM Major A CIM Minor A Status Status larm Inputs larm larm Chassis Temperature Online Good Enabled N A Major Major Off Off Off OK 1 Reset Major and Minor Alarm Relay Figure 3 CIM Management Screen Table 3
11. rough relay contacts on the front panel e Links up to eight chassis for system management e Distributes the clock signal on the management bus e Provides power to and monitors the optional fan tray r 4 a _ o y E A HANNA E UN UN Lo dee dou Ze voli ISSN MDODO 7777077770777 Me cda z po p 0 6 E HN NN ET Lo i i Edge Access ssoooy 96pz Figure 1 CIM in the UCS 1000 Chassis Model 1200 CIM User Manual 1 1 EdgeAccess Universal Chassis System 1 2 External Features Figure 2 shows the CIM front panel it includes a pushbutton LEDs and connectors Four LEDs that show module and alarm status Alarm acknowledgement pushbutton Six pin terminal block connector to forward alarms to external devices Two ports for modular cables to link multiple chassis through CIMs Four pin connector for power to fan tray N gt meme sm 2z sE O U MEN A 383 L 5 5 8 3 E Figure 2 CIM Front Panel 1 2 Model 1200 CIM User Manual EdgeAccess Universal Chassis System Chapter 2 Installing the CIM The CIM is installed in the UCS 1000 chassis in the bottom of slot 0 at the factory Occasionally you may need to install a CIM in a UCS 1000 if ordered separately 2 1 Install a CIM To install the CIM follow these steps 1 If multiple chassis will be linked set up the chassis ID numbers For details on setting the Chassis ID switch on each backplane see the User Manual
12. the alarms to the MAJ or MIN LEDs and the alarm relays These conditions cause a Major alarm e Recovery from total power failure e Power failure in a linked CIM e A major alarm in a module in the chassis These conditions cause a Minor alarm e Failure of one power supply in a redundant power supply configuration e Failure of the clock signal on the CIM e A minor alarm in a module in the chassis If an alarm occurs in a linked chassis configuration look for the chassis with the amber STA LED that chassis is generating the alarm When a CIM in a link loses power it signals both major and minor alarms to the external devices However the link between chassis does not break unless the link cables are unplugged To reset the alarm relays after resolving the cause of an alarm access the CIM Management screen type 1 Reset Major and Minor Alarm Relay and press lt Enter gt For information on alarms in other modules in the chassis see the users manual for the module 3 2 Model 1200 CIM User Manual EdgeAccess Universal Chassis System Chapter 4 CIM Specifications Physical Specifications Dimensions 5 0 H x 0 9 W x 10 0 D 130 mm x 2 3mm x 264 mm Weight 9 oz 0 25 kg Environment 0 to 50 C Up to 95 Humidity noncondensing Power 48 VDC 400 mA maximum plus 400 mA for optional fan tray Regulatory Compliance ETL cETL CAN CSA C22 2 No 60950 UL 60950 EN 60950 FCC Part 15B Class A IC CS 003 C Tick AS NZ
Download Pdf Manuals
Related Search
Related Contents
熱伝導ガス分析計 TAV.17_Piano di sicurezza e coordinamento warning - Scag Power Equipment Panasonic DMC-TZ30 Arnes Anticaida AFG Nokia 6303i classic User Guide エルモCCDカラーカメラ SV2030/QNW4002 取扱説明書 XLED-5MPG_3MPG_2MPG_ Manual_ Sony SLV-XA147PS User's Manual 625-515 service manula Copyright © All rights reserved.