1. the red light flashes slowly if the wired inputs trigger the alarm or wireless sensors trigger the alarm 1 If the SMS alarming function is enabled the system will send the corresponding SMS based on the trigger port wired IN1 wired IN2 wired IN3 wireless sensors It will then call the stored numbers If the SMS alarming function is disabled it will just call the stored number directly 2 After the alarm is set off and the system calls you you do not need to input the password again to control the system Standard components and optional available components Additional wireless products optional Optional sensors detectors are available separately They include remote controllers wireless PIR wireless gap sensor wireless gas detector wireless smoke detector panic button wireless sirens etc Please contact usfor full details on all the supported wired wireless sensors Technical Parameters GSM Alarm Module Operating voltage DC12V Average power AC DCexchanger 12V Wireless receiving distance gt 80m open space Operating Frequency 433 92 MHz GSM Frequency 900 1800 1900 MHz Outer Alarm Siren Volume 110 dB Working Condition Temperature 10 C to 40 C Working Humidity 10 90 rh Wireless Gap Detector Door Window Contact Power Supply DC12V inner 12V battery Static Current lt 20 mA Transmission Current lt 15mA Transmission Frequency 433 MHz 0 5 MHz Transmission Distance No obsta
2. the 20 seconds after the power is on After applying 12Vdc to the system when signal LED light is in red colour trigger the sensor you want to match to the system to emit a signal If the main unit picks up this signal the wired siren will give short rings and signal LED will flash in red If no sensoris triggered within 20 seconds the system starts to search for GSM network and signal LED flashes in orange Test all sensors after adding to the system and repeat above procedures if more sensors need to be added Maximum number of wireless zones that can be coded by the systemis 16 But you can register countless wireless sensors by grouping sensors to the same zone same address code 8 digit jumper setting in sensors 3 How to cancel the lost remote controllers in the alarm system If a remote sensor is lost the user needs to clear this remote controller Press the RESET key on the back of the alarm system and then plug in power The status signal light flashes once meaning the alarm system reset successfully After resetting the alarm system all setup come back to the time when it came from the factory The origin password is 123456 Repeat the add sensor instructions above to match back other sensors and remotes 4 How to test the alarm system function When the poweris on and tums into the disarm status users can arm it through remote controller arm key or by sending a SMS Password 1 1 When the alarm system is in arm status
3. SMS to set the alarm phone number and the SMS command should be sent as follow password operating code 51 55 phone number Send SMS 123456 51 1st phone number means storing 1st phone number Send SMS 123456 52 2nd phone number means storing 2nd phone number Send SMS 123456 53 3rd phone number means storing 3rd phone number Send SMS 123456 54 4th phone number means storing 4th phone number Send SMS 123456 55 5th phone number means storing 5th phone number Send SMS to delete a stored phone number 123456 51 means deleting the 1st phone number Other phone numbers can be deleted using similar method but changing to 52744 53 54 and 55 4 Send a SMS to acquire the phone numbers stored 12345645 0 2 The alarm system has fixed 5 SMS alerts alert No 1 3 correspond to wireless zones 1 3 alert No 4 corresponds to wireless zones 4 16 alert No 5 corresponds to the wired zones 1 3 When wireless Zone 1 is triggered Wireless Activated 1 When wireless Zone 2 is triggered Wireless Activated 2 When wireless Zone 3 is triggered Wireless Activated 3 When wireless Zone is triggered Wireless Activated I I 4 16 When 11 12 or 13 wired zone is triggered Wired Activated J J 1 3 User can send a SMS to replace the content of the alarming SMS Send SMS 123456 81 Front Door Open replaces the Wireless Activated 1 for alert No 1 Send SMS 123456 82 Back Door Open replace the Wireles
4. TX GSM SMS Auto dial Alarm System Installation and User M anual Product Features 1 16 wireless zones 3 wired zones alarm system suitable for small to medium size offices and homes 2 The system uses GSM communication channel which can be installed in remote areas with GSM coverage 3 The system supports 900 1800 1900 MHz GSM SIM cards CDMA or other SIM cards cannot be used 4 The system can store and dial SMS 5 phone numbers 15 digits maximum If an alam occurs the numbers stored will be dialled SMS in order starting with the first phone slot You can set to dial to monitoring centre police or the administrator 5 By using the remote controllers you can arm disarm or set off the alarm 6 You can control the system by calling the system anytime wherever you are For security reasons a PIN code must be used for accessing the system 7 The system supports all kinds of wireless sensors PIR motion sensors door window contact sensors gas detectors smoke detectors panic buttons and infrared balusters are available 8 The system supports wired sensors NO NC contacts different wired sensors are available 9 The system does not need aland telephone line to operate itis suitable for cottages houses shops and garages The system only needs a GSM network 10 With back up batteries inside the system can detect AC power cut off and send SMS alert to the numbers stored 11 For weak GSM signal area an ext
5. al zone disarm 39 1 16 wireless zone 21 23 wired zone 11 Require the telephone No 50 12 Edit the first phone number 51 Phone number 0 15bit 13 Edit the second group phone number 52 Phone number 0 L5bit 14 Edit the third group phone number 53 Phone number 0 15bit 15 Edit the fourth group phone number 54 Phone number 0 15bit 16 Edit the fifth group phone number 55 Phone number 0 L5bit 17 Require the content of the SMS 80 18 Edit the first zone alarm SMS 81 he content of SMS 0 24 letters 19 Edit the second zone alarm SMS 82 the content of SMS 0 24 letters 20 Edit the third zone alarm SMS 83 the content of SMS 0 24 letters 21 Edit the I alarm SMS 84 the content of SMS 0 24 letters I Zone 4 16 22 Edit the wired zone alarm SMS 85 the content of SMS 0 24 letters Wired Zone 1 3 23 Require the status of outlet 90 24 Set the OUT1 91 1 Outlet Lhigh 91 0 Outlet 1 low 25 Set the OUT2 92 1 Outlet Lhigh 92 0 Outlet 1 low 26 Set the loudspeaker KTLK 93 1 Speaker on 93 0 Speaker off 27 Set the RELAY 94 1 Relay close 94 0 Relay open 28 Set input type for IN1 95 14 NC Type 95 0 NO Type 29 Set input type for IN2 96 14 NC Type 96 0 NO Type 30 Set input type for IN3 97 14 NC Type 97 0 NO Type 3 How to setup the alarm phone numbers 5 groups and the content of SMS alerts 5 groups 1 User can send a
6. cle 80m Intemal Distance 15mm Working Condition Temperature 0 C to 45 C Working Humidity 10 90 rh Wireless PIR Detector Power Supply DC9V inner 9V battery Static Current lt 100 mA Transmission Current lt 20mA Transmission Frequency 433 MHz 0 5 MHz Transmission Distance No obstacle 80m Detective Speed 0 3 3m s Detective Distance 5 12m Detective Range Horizontal 110 Vertical 60 Working Condition Temperature 0 C to 45 C Working Humidity 10 90 rh Remote Control Power Supply DC12V inner DC12V battery Transmission Current lt 15mA Transmission Frequency 433 MHz 0 5 MHz Transmission Distance No obstacle 80m Troubleshooting Section GSM Problem The light keeps flashing orange meaning the GSM network has not been established 1 The SIM card circuit side should face downwards slide the sim card holder into the slot of the main unit carefully to make sure the card has the contact with the main unit circuit board 2 The SIM card should use 900 1800 1900 MHz GSM Band Only use GSM SIM card not CDMA or 3G 3 Make sure the SIM card has NO password NO phone number or any message history in it 4 Apply the power with the 12V 2A power adapter we supplied and connec it to the main supply 5 Use the antenna this is for the GSM reception 6 If possible try with another unlocked SIM card different company or try the alarm at another location to check GSM reception If the ala
7. e with zone number indicating which wired zone is triggered at the end of the message When the alarm is set off via the wired sensors and send out a SMS it will show Wired Activated J J 1 3 Sensors can be NO normally open or NC normally close type You can connect more than one sensor at one input by connecting the sensors in parallel forNO or in series for NC lt 2000hms 5 Connecting switched output devices Home appliance Control The system has two open collector outputs OUT1 and OUT2 one speaker output KTLK and one internal relay RELAY controlled by telephone or SMS text commands Intemal onboard relay is activated for two minutes when an alarm occurs and it can be controlled through telephone or SMS text commands It can be used forexample to turn on alamp to scare away the thief The open collector outputs can be used directly if your equipment allows this it can operate a relay Do connect an anti parallel diode with relay coil for circuit protection 6 How to distinguish the LED on the main panel LED during power on When the unit is supplied with power the Signal LED first turn on static red colour for about 15 20 seconds this is the time to record any wireless device that is not matched to the system apply to new accessories that is bought separately After this period the Signal LED changes to flashing orange colour searchingfor the GSM network If the system already installed with phone
8. ernal antenna can be used 12 Two open collector outputs are available to be used according to customer demands 13 One onboard relay and one open collector speaker output are available for customer application 14 The system can control home electrical appliances optional switch box is available 15 Easy installation and operation Installation Guide 1 Insert a SIM card to the alarm unit Press the yellow button next to the card slot gently with a small screwdriver The SIM card tray will come out Put the SIM card in correct direction metal contacts face down and insert into the system carefully Attention Metal contacts of the SIM card must face down Make sure itis inserted correctly into the unit Before inserting SIM card into the alarm unit use a regular mobile phone to do the following steps Set the SIM card PIN code Password request to off Delete all stored numbers or any message histories 2 Connect the antennas Attention Be careful do not over tighten the antennas Connect the antennas before power up the system 3 Connect the optional siren to alarm system Connect solid black wire to GND port and red or black white wire to SIREN port If the siren has two white wires instead connect smooth surface wire to GND and patterned wire to SIREN port 4 Connecting wired sensors Three inputs are available to connect wired sensors Inputs are independent but they share the same SMS alert messag
9. ler 1 Arming button dosed padlock press it to arm system Wired siren will give a short ring 2 Disarm button open padlock press it to disarm system Wired siren will give two short rings 3 Panic button bell press it and wired or wireless siren will start to ring continuously alarming the others Using phone call or SMS text message to control the GSM alarmsystem Calling the alarm system after one ring unit will answer and a beep will be heard You have to input the password followed by key Default password is 123456 System responds with beep and now you can send several commands and change some settings Some of the settings can only be set by SMS messages Command 7 11 17 23 Sending SMS text message text message should start with password and followed by system command If setup is completed user will receive a confirmation SMS message 2 System Commands 1 Arm Disarm 1 14 Arm 1 0 Disarm 2 Alarm immediately on spot 3 14 On 3 0 Off 3 Immediate site monitoring 4 14 On 4 0 Off 4 Alarm with siren 11 1 On 11 0 Off 5 Alarm with SMS 12 1 On 12 0 Off 6 Alarm with dial phone 15 1 On 15 0 Off 7 Require each zone s status of arm or disarm 30 8 Change the password 31 code 6 digit Default password 123456 Note It is wise to change PIN code at first login in alarm system 9 Partial zone arm 38 1 16 wireless zone 21 23 wired zone 10 Parti
10. numbers ready for auto dial when itis being triggered then the Signal LED will change to FLASHING GREEN colour when it finds the GSM network indicating CORRECT OPERATION If there is no phone number in the system then the Sgnal LED will change to static green colour phone numberis required for auto dial If the alarm system light turns red and flash quickly meansit is being controlled with long distance function Signal LED light Green light is ON Disarm status Green light flash slowly Arm status Orange light flash slowly Arm in progress or seaching GSM network during power on Red lightis ON Matching sensors period during power on Red light flash slowly Alarm triggered Red light flash fast Receiving call SMSin remote distance 7 More explanation on the side connection ports The GND1 2 3 ports Ground lines The SIREN port Siren audio output wireless siren transmitter The RELAY ports Relay inputs normally open It will keep closed for 2 minutes when alarming KTLK Loudspeaker output can use with SX14 loudspeaker OUT2 OUT1 Output controls can use with SXS switch box IN3 IN2 and IN1 Inputs for NO NC wired detectors Attention Backup batteries are built in the main unit Power is present in the main uniteven when power supply is not plugged in AC socket or during power cut off The user will receive a message Power off when the AC power is off Operating the System 1 Use of remote control
11. rm has established a GSM network then the signal LED should change to green colour Sensors Remotes The sensor does not trigger the alarm system 1 Check the sensor battery 2 Re match the sensor to the system according to adding a new sensor section
12. s Activated 2 for alert No 2 Send SMS 123456 83 Fire Alarm replace the Wireless Activated 3 for alert No 3 Send SMS 123456 84 0ther Sensors replace the Wireless Activated 1 for alert No 4 Send SMS 123456 85 Wired Sensors replace the Wired Activated J or alert No 5 Acquire the content of SMS 123456 80 Note the content of SMS edited cannot exceed 24 letters Advanced Instructions Only performed under technical guidance 1 Resetting the system NOTICE Resetting the system will cause all coded information and messages to be lost System will be loaded with basic factory settings The passwords will be back to the default value 123456 You must code register all wireless sensors again after reset Reset procedures System must be disarmed and then power off Press and hold the reset button meanwhile connect a 12Vdc supply to the alarm system Release the reset button the alarm LED will flash once Wait until the status signal LED changes to green colour Now system is reset and back to factory settings the password is 123456 2 How to add new sensors to the alarm system Registering wireless sensors with control unit Sensors and remote controls delivered in kit are already added registered to the system Plug in DC 12V power supply to the alarm system If the alarm system needs to add new sensors such as PIR motion sensors remote controls and so on you can do so within