1. but the growing complexity of many control requirements in sophisticated products indicates a need to move to more powerful processors The ARM and its variants offer manufacturers the opportunity to move directly to 32 bit controllers at low cost and with a great deal of flexibility for designing custom controllers The ARM processor is always differed from other commercially available RISC processors in that it 1s intended to meet a price performance ratio rather than to be the most powerful processor available ARM processors offer an extremely good price performance ratio compared to other processors The Cortex M3 processor design has some innovative and much improved features and capabilities when compared with the ARM7TDMI processor Since the Cortex M3 processor can finish a task quicker than an ARM7TDMI more time can be spent in sleep mode reducing the active power of the system and thereby enabling better system performance and energy efficiency The architecture uses a Thumb 2 technology and Thumb 2 technology use 31 less memory which reduces system overhead in comparison with the pure 32 bit code At the same time it provides 38 higher performance than the existing technology solutions based on Thumb The Stellaris Ethernet Controller consists of a fully integrated media access controller MAC and network physical PHY interface device The Ethernet Controller conforms to IEEE 802 3 specifications and fully supports IOB
2. is executed This routine checks for the connection checks for the new data ready to transmit or for the acknowledgement for the previous packet from the host application and sends the new data of ADC if it is ready After the conversion of the data from ADC channels the ADC interrupt is generated The interrupt handler routine will clear the interrupt flags get the data from the FIFOs and make frame to transmit it over ethernet C LabVIEW Programming One benefit of LabVIEW over other development environments is the extensive support for accessing instrumentation hardware Drivers and abstraction layers for many different types of instruments and buses are included or are available for inclusion The abstraction layers offer standard software interfaces to communicate with hardware devices The provided driver interfaces save program development time 1 TCP Tools TCP protocol can be implemented on LabVIEW very easily with TCP tools TCP tools are readily available with basic installation of LabVIEW Instead of writing the code for TCP protocol LabVIEW has the building blocks which takes care of everything needed for TCP communication TCP tools consist of few useful nodes or VIs which are explained in this section net address service name connection ID port remote address timeout ms wait forever 1 remote port error in no error error out resolve remote address Fig 3 TCP Listen TCP Listen In any program to s
3. to use main oscillator along with the PLL Software specifies the output divisor to set the system clock frequency and enables the main PLL to drive the output 2 Ethernet The LM3S8962 microcontroller has fully integrated Ethernet controller Only an RJ45 jack with integrated magnetics and a few passive components are needed to complete the 10 100baseT interface The LM3S8962 supports automatic MDI MDI X so the EVB can connect directly to a network or to another Ethernet device without requiring a cross over cable ADC Interrupt Clear Interrupt Get Data from Fig 2 Interrupt based ADC firmware 3200 Patel Hiren etal IJCSIT International Journal of Computer Science and Information Technologies Vol 3 1 2012 3199 3204 3 ADC The hardware resolution of the ADC is 10 bits Software based over sampling technique results in an improved Effective Number of Bits ENOB in the conversion result The oversampling gathers additional conversion data from an input signal Any sampling frequency selected above fS is considered to be oversampling and when combined with averaging techniques improves the ENOB For each bit of accuracy improvement the signal must be oversampled by a factor of four This is possible because averaging the oversampled results also averages the quantization noise thus improving the Signal to Noise Ratio SNR which has a direct effect on the ENOB 4 TCP Application TCP IP is the under
4. ASE T and IOOBASE TX standards In addition the Ethernet Controller supports automatic MDI MDI X cross over correction The LM3S8962 ADC module features 10 bit conversion resolution for four input channels plus an internal temperature sensor The ADC collects sample data by using a programmable sequence based approach ADC acquisition supports single ended and differential input configurations at sampling rate of ADC up to 500 thousand samples second The start of the conversion can be controlled by various triggering such as Controller software Timers Analog Comparators PWM and GPIO The GPIO module supports 5 42 programmable input output pins UI ARM FIRMWARE Application software is the layer of software for easily communicating with the hardware Cortex M3 series of Stellaris family from Texas Instruments supports various tools for programming such as IAR workbench Code composer Studio and KEIL Application software code for the ARM processor is classified in two program flows TCP Initialisation App Call Data on Port Initialize Enable conection Return Fig l ARM system firmware flow chart A Main Program Flow Main program module is written to control the execution sequence of the program The configuration of various hardware modules are carried out within this code The configuration steps are to be carefully arranged so that it might not conflict with other settings 1 Clock The card is configured
5. ISSN 0975 9646 Patel Hiren etal IJCSIT International Journal of Computer Science and Information Technologies Vol 3 1 2012 3199 3204 GUI Based Data Acquisition System Using ARM Cortex M3 Microcontroller Patel Hiren Patel Dipak 1 Electronics and Telecommunication Dept BVM Engineering College Vallabh Vidyanagar Gujarat India 2 Electronics Dept BVM Engineering College Vallabh Vidyanagar Gujarat India Abstract The architectural evaluation in microcontroller development plays important role in the field of embedded systems The embedded systems in industrial application can be developed around such microcontroller like ARM advanced RISC machine to optimize the system performance This paper includes description about the data acquisition system using ARM Cortex M3 and GUI based LabVIEW software tools The system designed is not specific for any sensor acquisition so any sensor having signal conditioning circuit built can be connected to the DAQ card ARM controller is used as heart of the DAQ Due to the peculiar features of the ARM Cortex it is used in the system Keywords ARM controller Microcontrollers Medical Instrumentation Wearable systems I INTRODUCTION ARM based designs have seen an immense growth during the past few years with free and open software tools becoming an integral part of embedded systems development These free and open source codes offer a high quality tool chain for ARM
6. SETUP One of the criteria while designing this application also includes that it has to be stand alone application software 1 e it can be installed on any machine and start the acquisition process LabVIEW application builder is very useful tool when we are designing an application that runs on the system that does not have LabVIEW installed on it Tool of LabVIEW Application Builder builds the application exe i e executable file as well as installer which can be installed on any machine with required specification For creating a host terminal which can communicate directly with the DAQ card some setting are to be made As if installing the application software enabling the LAN connection and setting the IP address of terminal to the one specified for establishing the communication i po a re A Accecc TCP CONFIGURATION BIT po 7 Por 2 4 iL ent Car He ft Timeout ms 1 1 mem ime bee eal meen ie m s nett mms mm fe eet hemen ce ieee Tem bo Fig 7 GUI Settings Tab V DAQ APPLICATION Once starts the program he has to give the user name and password to get access to the acquisition program After this activation of process launches the DAQ application Before starting the acquisition the settings are to be configured The fig 7 below shows the settings tab for configuring the TCP communication For TCP Configuration takes Host port as input for listening to connection DAQ application can be cla
7. ata types as well as match the same for reading part The fig 11 shows the reading code This code consists of a file I O node which reads the data from file which is browsed by the user and posts it to the waveform indicator Along with the display of the data the values are also shown in table format VI CONCLUSIONS The data acquisition designed here integrates a DAQ card which is designed around ARM Cortex M3 MCU and LabVIEW application The combination of the two proves very beneficial in analysis Each of the above has unique peculiarities which is utilized together to give best performance required ARM cortex perfectly matches and is best suited for the solutions related to the automation acquisition and networking fields The low cost MCU based design makes system affordable to the industries The networking capability enables highly efficient data analysis process The LabVIEW platform interfaces with the ARM based DAQ card The tools available with it prove very beneficial in developing application faster and easier VII FUTURE WORK Data acquisition with networking facilities was the foremost aim of the design Few more features could be included to make system more reliable more efficient and more user friendly Report generation will generate the report for the logged data DAQ card can be connected in LAN for analysis from remote terminal present on LAN DAQ card can be connected with Internet so that data can be acce
8. ber of bytes from a TCP network connection returning the results in data out mode standard connection ID bytes to read timeout ms 25000 error in no error connection ID out data out error out Fig 5 TCP Read bytes to read is the number of bytes to read data out contains the data read from the TCP connection This pin is connected to the string indicator After reading data this indicator contains data frame in string 3201 Patel Hiren etal IJCSIT International Journal of Computer Science and Information Technologies Vol 3 1 2012 3199 3204 format This data is converted to the numeric format for interpretation and plotting connection ID connection ID out On a abort F error in no error error out Fig 6 TCP Close Connection TCP Close Connection Once we complete data acquisition the connections is to be closed separately using their connection ID TCP Close Connection node closes a TCP network connection There are few inputs and outputs in the nodes of the toolkit which are undefined due to repetition of those inputs outputs in previous node description 2 Host Application DAQ card is connected to the computer for online and offline analysis There has to be application software which takes the data from the DAQ card and does the interpretation Host application is the application which runs on the terminal connected directly with the DAQ card IV APPLICATION
9. development These systems have acquisition of signals as the basic part 1 All this industries need a platform which can do their automation jobs For this generally readily available DAQ cards from different vendors are available These cards have different features according to design and cost 2 The DAQ card that we designed has Analog inputs Digital inputs and outputs Interrupts timers and at least one PC interface ports like Serial USB Ethernet GPIB etc The objective was to design the DAQ System to target the recent needs in the industries and make it compatible with the new trends in the technology The utilization of the facilities flexibilities and the available recourses to match the requirements is targeted in the design There are wide ranges of systems available in market which performs data acquisition along with the logging but at very high rates This project is designed with keeping in mind the recent trends of applications and its requirements along with the cost constraints There are certain other goals which are targeted through this design which are as included like industrial application affordable to small scale Industries system can take place of systems based on monitoring temperature pressure humidity pH level and other sensors as well II DATA ACQUISITION SYSTEM Generally a system always has a controlling unit or the processing unit Function of this unit is to acquire the data and convert it to th
10. e usable format DAQ card uses ARM Cortex series processor for the acquisition and conversion tasks The data acquisition system designed here has processing part distributed between two systems Both systems have to perform tasks coherently and individually so that burden does not come upon any one of the systems These processing systems are classified according to the tasks performed The DAQ card is capable of taking data from any sensors giving output in designed range of analog input 1 e within reference voltage limits Signal conditioning of the sensor signals are to be carried out before it could be connected to the system Computer manipulates the data as well as stores it in a file thus it also does function of data logging Along with the data acquisition and data logging it also does communication tasks with DAQ card DAQ card is connected to the transducers The transducers cards are having the signal conditioning circuit on the PCB So the signals coming from the transducers are ready to be interfaced with the DAQ card The system as a whole classified in two primary design modules as DAQ Card which having ARM Cortex M3 as a core controller and computer along with GUI Graphical User Interface based software for display of acquired data by software tool LabVIEW from National Instruments inc 4 5 A ARM Cortex ARM Cortex has wide variation in versions Differing with the version the features and the applications also va
11. erage The fig 10 shows the graph tab and table tab Until the connection is established the connecting progress bar will be running Once the connection is established the graph will plot the received data and table will show the values with time stamp B Data Logging Always the data that are coming from the DAQ card are much faster so if detailed analysis is to be carried out than the data must me logged so that time consuming analysis can be carried out Even if there is need to compare different data may be data from different sensors or data from same sensor but for different time than such logged data is very much useful There is an option given in the settings tab called Logging if this option is selected than the data is logged in a binary file format The averaged data along with the time stamp and delta time dt are collected in an array outside the while loop The fig 11 shows the code for data logging in a case structure The file that is created is having the DAT as the extension C Post analysis Retrieving data is carried out in post analysis part Because the data format is very important in reading the data back to the display controls For example if the data written is having 5 bits precision and if reading part tries to read 4 bit or 6 bit precision data than due to the mismatch of the data types the reading node will send error for mismatch of the data So it is very essential to select proper d
12. esearch LLC 9 Guido Moritz Steffen Priiter Dirk Timmermann Real Time Service oriented Communication Protocols on Resource Constrained Devices International Multiconference on Computer Science and Information Technology ISBN 978 83 60810 14 9 10 Adam Dunkels Full TCP IP for 8 Bit Architectures International conference on mobile applications systems and services MOBISYS 2003 San Francisco May 2003 3204
13. lying protocol used for web page transfers e mail transmissions file transfers and peer to peer networking over the Internet For embedded systems being able to run native TCP IP makes it possible to connect the system directly to an intranet or even the global Internet Traditional TCP IP implementations have required far too much resource both in terms of code size and memory usage to be useful in small 8 or 16 bit systems Code size of a few hundred kilobytes and RAM requirements of several hundreds of kilobytes have made it impossible to fit the full TCP IP stack into systems with a few tens of kilobytes of RAM and room for less than 100 kilobytes of code The uIP TCP IP stack is intended to make it possible to communicate using the TCP IP protocol suite even on small 8 bit micro controllers Typical code size is on the order of a few kilobytes while RAM usage can be as low as a few hundred bytes B TCP and ADC Program Flow This application program consists of 3 sub programs which are called as per the interrupt generated or any activity detected These sub program modules are as listed below 1 ulP initialization routine The uIP initialization routine includes setting up of the connection with remote host The IP address of the host terminal and the port number with which connection 1s to be established is used to connect 2 Ethernet Activity routine Whenever there is any activity detected on the ethernet than service routine
14. ry to a great extent ARM Cortex processor product families are based on ARMv7 architecture The MCU chosen here falls in mid range of cost and performance But so far as the system requirements are concerned the Cortex M3 is best suited to the application 6 7 ARMv 7 architecture defines a series of three clear division of labor A series for cutting edge virtual memory based operating system and user applications R for real time system M series for microcontroller optimized and low cost applications ARM Cortex M series is for those who are very sensitive to the development costs while increasing performance requirements of small embedded applications off are designed mainly for the microcontroller The ARM _ Cortex M3 processor is a low power processor that features low gate count low interrupt latency and low cost debug It is intended for deeply embedded applications that require fast interrupt response including microcontrollers and automotive and industrial control systems In the industrial field the user requires a faster speed interrupt so Cortex M3 is best suited in the industrial applications 3199 Patel Hiren etal IJCSIT International Journal of Computer Science and Information Technologies Vol 3 1 2012 3199 3204 B LM3S8962 ARMv7 Cortex M3 Embedded control forms a large part of the market for microprocessors The embedded controller market has traditionally focused on 8 bit microprocessors
15. ssed from any internet connected computer REFERENCES Jeffrey Travis Jim Kring LabVIEW for Everyone Graphical Programming Made Easy and Fun 3rd Edition July 27 2006 Prentice Hall Part of the National Instruments Virtual Instrumentation Series eBook ISBN 10 0 13 241224 1 ISBN 13 978 0 13 241224 7 User Manual Introduction to Data Acquisition http zone ni com devzone cda tut p id 3536 User Manual LabVIEW 8 2 Building a Stand Alone Application National Instruments http zone ni com reference en X X help 37 1361B 01 lvhowto building a_stand_alone_app Bruce Mihura LabVIEW for Data Acquisition Published on June 26 2001 by Prentice Hall eBook ISBN 10 0 13 244127 6 ISBN 13 978 0 13 244127 8 Application Note ADC Oversampling Techniques for Stellaris Family Microcontrollers http www ti com stellaris Application Note Using the Stellaris Ethernet Controller with Micro IP uIP http www ti com stellaris Stellaris LM3S8962 Microcontroller datasheet http www ti com stellaris Jan Axelson EMBEDDED ETHERNET AND INTERNET COMPLETE Designing and Programming Small Devices for 3203 1 from 2 3 4 5 6 7 8 9 Patel Hiren etal IJCSIT International Journal of Computer Science and Information Technologies Vol 3 1 2012 3199 3204 Networking Create tiny Web servers and use TCP IP to communicate over local networks amp the Internet Published by Lakeview R
16. ssified in 2 modules depending upon coding structure as on line Analysis and offline Analysis A Online Analysis DAQ card continuously acquires the raw data from the transducers and converts it to a digital format These data is continuously sent to the host terminal So the analysis can be instantaneous or it can be post analysis Here we are to discuss the instantaneous analysis mode which is termed here as Online Analysis Fig 8 Code Online Acquisition The data that are arrived at the ethernet port are taken and converted to the interpretable form After these data are plotted on the graphs with respect to the time it was received at the terminal Fig 10 GUI Table Online Acquisition Fig 8 shows the part of code which does the acquisition of data through TCP Read node in while loop TCP read node is configured for acquisition of the 119 bytes of 3202 Patel Hiren etal IJCSIT International Journal of Computer Science and Information Technologies Vol 3 1 2012 3199 3204 data The acquisition is controlled by the error of the reading node which means if the connection is broken than the acquisition will stop automatically The data read from the ethernet comes in string format which is manipulated and converted to represent the measure of physical quantity The data frame received consists of data from 4 channels with 4 samples each To display the data on indicators the data of 4 channels are av
17. tart with a TCP communication there has to be a client which listens to the server Generally a server starts the communication where in the client must be listening to the specified port to establish the communication This node creates a listener and waits for an accepted TCP network connection at the specified port net address specifies on which network address to listen port is the port number on which you want to listen for a connection This is the port number of the host computer timeout ms is the period of time in milliseconds to wait for a connection TCP Open Connection Whenever server wants to start the connection it has to open a new connection For opening a new connection we use this node This new connection requires some specific information such as TCP network connection with the address and remote port or service name address remote port or service name timeout ms 60000 error in no error ocal port connection ID error out Fig 4 TCP Open Connection address is the IP address of the computer with which connection is to be established remote port or service name can accept a numeric or a string input remote port or service name is the port or name of the service with which we want to establish a connection TCP Read Once the connection is connected server will sent he data on the connection To read that data we use this TCP Read node It reads a num