Home

Manual - Microh DJ

image

Contents

1. 3 pin XLR output of your controller and the other side to the male 3 pin XLR input of the LED COB100 PAR RGBWA To connect the units to DMX you must daisy chain the fixtures together as referred in the diagram below Always end your DMX 512 connection with a DMX terminator DMX OUTPUT CONTROLLER FIXTURE 1 FIXTURE 2 FIXTURE 3 RE UPTO 30 UNITSIN MASTER SLAVE MODE XLR CABLE XLR CABLE XLR CABLE DMX Output DMX Input 3 Pin XLR Socket 3 Pin XLR Socket COMMON ee DMX512 OUT Y o ome DMX512 IN 3 Data SPIN XLR DMX 3 PIN XLR For installations where the DMX cable has to run a long distance or is in an electrically noisy environment it is recommended to use a DMX terminator This helps in preventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 Q resistor connected between pins 2 and 3 which is then plugged into the output XLR socket of the last fixture in the chain Please see illustrations below 120 2 a y i PIN 3 PIN 2 6 SETUP MENU Display Function 6607 omksemm6 sun sounpactive ron fumo ARTO macros E COLOUR CHASE 5 COLOUR SELECTION un SLAVE MODE NOTE To adjust the brightness of the full on press and hold the MODE button for more than 5 seconds The display will show u255 use the UP or DOWN buttons to adjust the brightness Press ENTER to confirm 7 DMX CHANNEL MODES 4 Channel Mode Chan
2. MICROH E www microhdj com USER MANUAL UV BRICK 16 Keep this manual for future reference INTRODUCTION AND UNPACKING Thank you for purchasing the MICROH UV BRICK16 wash fixture For your own safety and knowledge please read this manual before installing or operating the device This manual covers the important information on installation and applications Please install and operate the fixture according to instructions Meanwhile please keep this manual for future reference The MICROH UV BRICK16 wash fixture is made of a new type of high temperature cast aluminum casing The fixture is designed and manufactured strictly following CE standards complying with international standard DMX512 protocol This fixture is applicable but not limited to large scale live performances theater studio nightclubs and discos The MICROH UV BRICK16 wash fixture uses 16 x 3W UV LED s which features high brightness and stability Please carefully unpack it when you receive the fixture and check if it was damaged during the transportation Please check whether the following items are included inside the box Fixture One Power Cord One User Manual One 2 SAFTEY INSTRUCTIONS CAUTION ELECTRIC SHOCK WARNING USE EXTREME CAUTION WHEN HANDLING WIRES This device has left the factory in perfect condition In order to maintain this condition and to ensure safe operation it is absolutely necessary for the user to follow the safety i
3. detailed electrical check by approved technician every three months is advised Ensure the circuit contacts are in good condition We recommend a frequent cleaning of the device Please use a moist lint free cloth Never use alcohol or solvents There are no serviceable parts inside the device Please refer to the instructions under Installation instructions Should you need any spare parts please order genuine MICROH parts from your local dealer IF YOU SHOULD EXPERIENCE ANY PROBLEMS OR ISSUES PLEASE CONTACT MICROH PROFESSIONAL PRODUCTS BY EMAIL AT info microhpro com In the event that your unit is defective in any way please contact your local dealer to obtain an RA number for service repair DISCLAIMER MICROH believes that the information contained within this user manual is accurate However Microh is not responsible for any error or addendums to this manual If you have any comments or general suggestions on how this manual can be improved please contact info microhpro com Thank you MVMICROFR 2 www microhdj com
4. llation material being used and periodic safety inspection of all installation material and the fixture are all imperative and should only be performed by a qualified technician Improper installation can result in bodily injury and damage Be sure to complete all rigging and installation procedures before connecting the main power cord to the appropriate wall outlet Floor Mounting Set the 2 brackets at your desired angle and aim your fixture accordingly Please see diagram below Clamp Mounting The MICROH UV BRICK16 provides a unique mounting bracket assembly that integrates 2 brackets to be used to mount on a truss or the floor When mounting this fixture to truss be sure to secure an appropriately rated clamp to the included bracket fitted through the center hole As an added safety measure be sure to attach at least one properly rated safety cable to the fixture Regardless of the rigging option you choose for your MICROH UV BRICK16 wash fixture always be sure to secure your fixture with a safety cable The fixture provides a built in rigging point for a safety cable on the hanging bracket as illustrated above Be sure to only use the designated rigging point for the safety cable and never secure a safety cable to a carrying handle 5 DMX 512 CONTROL CONNECTIONS This fixture complies with international USITT DMX standards and can be used with either a 3 pin or 5 pin DMX connector Plug in the provided 3 pin XLR cable to the female
5. n and air flow If your fixture is or has become damaged in any way it shall be exclusively replaced or repaired by the manufacturer to avoid any hazard CAUTION Never touch the device during operation The housing may heat up CAUTION Never look directly into the light source as sensitive persons may suffer an epileptic shock CAUTION The electric connection must only be carried out by a qualified electrician 2 MOUNTING AND INSTALLATION Caution For added protection mount the fixtures in areas outside walking paths seating areas or in areas were the fixture might be reached by unauthorized personnel Before mounting the fixture to any surface make sure that the installation area can hold a minimum point load of 10 times the device s weight Fixture installation must always be secured with a secondary safety attachment such as an appropriate safety cable Never stand directly below the device when mounting removing or servicing the fixture Whether installing inverted on a truss ceiling or set on a flat level surface see illustration below Be sure this fixture is kept at least 0 5m 1 5 ft away from any flammable materials decoration etc Always use and install the supplied safety cable as a safety measure to prevent accidental damage and or injury in the event the clamp fails Mounting Points Overhead mounting requires extensive experience including calculating working load limits A knowledge of the insta
6. nel Function Value Description DIMMER 0 255 INCREASE DECREASE BRIGHTNESS STROBE 0 255 SLOW FAST FADE 0 255 RANDOM FADE s macro 07227 RANDOM FADE 128 255 RANDOM CHASE 9 TECHNICAL SPECIFICATIONS MODEL UV BRICK16 LAMP 16 x 3W UV LED s OPERATING TEMPERATURE 25 to 45 C VOLTAGE 90 240VAC 50 60Hz 50W FUSE 2A DIMENSIONS 320 H x60 W x180 L mm NET WEIGHT 3 kg WARRANTY 2 Year Limited Warranty 10 MAINTENANCE AND CLEANING The following points have to be considered during the inspection 1 All screws for installing the device or parts of the device must be tightly connected and must not be corroded 2 There must not be any deformations on the housing colour lenses fixations or installation spots ceiling suspension trussing 3 Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances 4 The electric power supply cables must not show any damage material fatigue or sediments Further instructions depending on the installation soot and usage must be handled by a skilled installer or technician Any safety issues must be resolved CAUTION DISCONNECT POWER BEFORE SERVICING In order to keep the fixture in good condition and extend the life we suggest regular cleaning to the fixture 1 Clean the inside and outside lens each week to avoid the light output from darkening due to accumulation of dust dirt etc 2 Clean the fan each week 3 A
7. nstructions and warning notes written in this user manual Important Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems If the device has been exposed to temperature changes do not switch it on immediately The arising condensation could damage the device Leave the device switched off until it has reached room temperature and is dry This device falls under protection class I therefore it is essential that the device be grounded The electrical connection must be carried out by a qualified technician The device should only be used with rated voltage and frequency Make sure that the available voltage is not higher than 120V as stated at the end of this manual Make sure the power cord is never crimped or damaged in any way as this could cause shock and damage If your power cord is damaged in any way please purchase a new cable from your local MICROH dealer Always disconnect power when the device is not in use or before cleaning it Never pull out the plug by tugging the power cord During initial start up some smoke or smell may arise This is a normal process and does not necessarily mean that the device is defective It should decrease gradually Please do not project the beam onto combustible substances Fixtures cannot be installed on or near combustible substances Keep more than 50cm distance from wall for proper ventilatio

Download Pdf Manuals

image

Related Search

Related Contents

Veera - Rapid Insight Inc.  Brother HL-1660E Printer User Manual  313 The String List Editor  440bx/zx at mainboard  Betriebsanleitung  CD-ROM 内取扱説明書 [第 2 部]  Pronto P10 - ts2i  Manual de instruções DCR-HC23E/HC24E/ HC26E/HC35E  Kramer Electronics 3.5mm, Plenum, 22.9m  TABLE OF CONTENTS  

Copyright © All rights reserved.
Failed to retrieve file