1. Ltd Product Manual Directory CONTENTS Page 1 Summarize 1 2 Specifications 1 3 Installation and Start up 5 3 1 Installation 5 3 2 Connection terminal 6 4 Screen Display 8 4 1 Panel diagram 8 4 2 Display Summary 8 5 Operating Mode 9 6 Setup Procedure 10 7 Safety Considerations 11 8 Maintenance 11 9 Technical Service 11 Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer P
2. 4 Menu key 7 previous menu Up and Down key Set the programming value Note Please see detail instructions of items at OPERATION MODE Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing P R China 8 lt Blue Jay Technology Co Ltd Product Manual 5 OPERATION MODE The instrument has three displays Every led will be on according to the parameter presently shown in screen When the 193P 9X4 is powered up the entire symbol will be on and the meter starts to self test After some seconds the meter is ready for operation and shows one of the available screens KE A Parameters on display can be switched by pressing key CKD or C gt LED shown on screen at any moment When the key XK is pressed the screen CURRENT values of each phase are now showing Pressing again the key XK the screen will show the following parameters successively In setting menu pressing CKD can move the setting cursor to left Pressing gt gt gt can enter the number 0 9 A L gt l This key named SET key pressing it can open the programming menu and return to previous menu r ae his key named Enter key pressing this key you can exit it with saving any modification that you might have done in menu operation press Enter key and user can go to the next menu Note Pres
3. lt Blue Jay Technology Co Ltd Product Manual BJ193PQ Three phase Combined Power Meter User Manual Version 1 1 Tel 0086 023 67636974 Email tech cqbluejay com Fax 0086 023 67636974 Add Redstone Road 2 17 3 Jiangbei District 400020 Chongqing P R China lt Blue Jay Technology Co Ltd Product Manual Read me When you use BJ193 X series Digital Meter be sure to carefully read this user manual and be able to fully understand the implications the correct guidance of operations in accordance with user manual which will help you make better use BJ193 series Multifunction Power Meter and help to solve the various problems at the scene 1 Before the meter turning on the power supply be sure that the power supply within the provisions of the instrument 2 When installation the current input terminal must non open voltage input terminals must Non short circuit 3 Communication terminal RS232 or RS485 is strictly prohibited to impose high pressure 4 Be sure the instrument wiring consistent with the internal system settings 5 When communicating with the PC instrument communication parameters must be consistent with the PC Please read carefully before using this user manual Please save this document Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing PR China 1 lt Blue Jay Technology Co
4. 1 input 2 j1 Current A phase S2 input Current B phase S1 input Current B phase S2 input Mo N O oa ANa Current C phase S1 input 9 Current C phase S2 input 11 Voltage A phase input 14 13 12 11 9 8 7 6 5 4 12 Voltage B phase input 13 Voltage C phase input 14 Neutral Voltage input Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing P R China 6 z 0O U gt lt Blue Jay Technology Co Ltd Product Manual IMPORTANT REMARK If power 0 01 is shown for any of the phases and voltage and current are not zero for this phase check out following points Assure that A B C phases coincide in voltage and current Correct polarity Reverse the current transformer placed at this phase Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing P R China 7 lt Blue Jay Technology Co Ltd Product Manual 4 Screen display 4 1 Panel diagram 4 2 Display Summary No Display Explanation 1 Digital display module Three lines 4 digital LED show measurement power data Indicator of the data Unit K means thousand M means million Enter key For menu selection and confirmation Used to open the menu and return to
5. IEC 61000 4 2 8KV test level 4 Electrical fast transient burst ee input ikv Power supoly IRV immunity test p PPly Surge Shock immunity test E ri m i mode test voltage 8 Work environment Temperature 20 C 60 C 4 F 140 F Humidity RH 20 95 No condensation 9 Protection Panel IP40 10 Storage Conditions Temperature 25 C 70 C 13 F 1587 Humidity RH 20 95 11 Power Supply AC DC 80 270V Maximum power consumption 3W 12 Dimensions L x W x H 96x96x71mm 3 78x3 78x2 80 inch 13 Installation hole size L x W 91 0 8 mmx 91 0 8 mm 3 58 0 032 inch x 3 58 0 032 inch Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing P R China 4 lt Blue Jay Technology Co Ltd Product Manual 3 INSTALLATION AND START UP The manual you hold in your hands contains information and warnings that the user should respect in order to guarantee a proper operation of all the instrument functions and keep its safety conditions The instrument must not be powered and used until its definitive assembly on the cabinet s door Whether the instrument is not used as manufacturer s specifications the protection of the instrument can be damaged When any protection failure is suspected to exist for example it presents external visible damages the instrument must be immediately power
6. angbei District 400020 Chongqing Tel 0086 023 86850812 Fax 0086 023 67636974 E mail tech cqbluejay com Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing P R China 11
7. ark Jiangbei District Chongqing PR China 2 lt Blue Jay Technology Co Ltd Product Manual 1 SUMMARIZE BJ193 X series Digital Meter is used for power quality monitoring factory automation and building automation These series can measure the power parameters in power grid Current Reactive power Voltage Apparent power Frequency Energy Active power Power factor It can replace many of a traditional analog measurement instruments improve system accuracy and reliability 2 SPECIFICATIONS 1 Reference standard Basic electricity GB T13850 1998 IEC688 1992 Active power GB T17215 2002 IEC61036 2000 Reactive power GB T17882 1999 IEC61268 1995 2 Accuracy standards 3 Input Voltage Rated 100 400V Current Rated 5A optional 1A Frequency 45 65Hz 4 Load Voltage lt 0 5VA phase rated 220V Current lt 0 5VA phase rated 5A Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing PR China 3 lt Blue Jay Technology Co Ltd Product Manual 5 Overload Current 2 times rated continuous 10 seconds for 10 times the rated Voltage 2 times the rated continuous 10 seconds for 600V 6 Dielectric strength IEC 688 IEC 255 3 1989 2kV AC RMS 1 minute between input output case power supply 7 EMC Test standard Test voltage Electrostatic discharge immunity
8. ay com Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing P R China 10 lt Blue Jay Technology Co Ltd Product Manual 7 SAFETY CONSIDERATIONS All installation specification described at the previous chapters named INSTALLATION AND STARTUP INSTALLATION MODES and SPECIFICATIONS Note that with the instrument powered on the terminals could be dangerous to touching and cover opening actions or elements removal may allow accessing dangerous parts This instrument is factory shipped at proper operation condition 8 MAINTENANCE The 193X does not require any special maintenance No adjustment maintenance or repairing action should be done when the instrument open and powered on should those actions are essential high qualified operators must perform them Before any adjustment replacement maintenance or repairing operation is carried out the instrument must be disconnected from any power supply source When any protection failure is suspected to exist the instrument must be immediately put our of service The instrument s design allows a quick replacement in case of any failure 9 TECHNICAL SERVICE For any inquiry about the instrument performance or whether any failure happens contact to Blue Jay s technical service Blue Jay After sales service Building 13 2 8 Jialing third village Pioneer Park Ji
9. ed off In this case contact a qualified service representative 3 1 Installation Mounting Instrument is to be mounted on panel cut out 97 0 8 x 91 0 8 mm All connections keep inside the cabinet Note that with the instrument powered on the terminals could be dangerous to touching and cover opening actions or elements removal may allow accessing dangerous parts Therefore the instrument must not be used until this is completely installed Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing P R China 5 lt Blue Jay Technology Co Ltd Product Manual Notes Auxiliary power BJ193X Series Power Meter with universal AC DC power input if not for a special statement we provide the 220VAC DC or 110VAC DC power interface for standard products Instruments limit work power supply AC DC 80 270V please ensure that the auxiliary power can match for BJ193 X series meter to prevent damage to the product A Suggest install 1A fuse in the fire line side B For the areas with poor power quality suggest install lightning surge suppressor and rapid burst suppressor to prevent lightning strikes 3 2 Connection terminal and drawing for BJ193P 9X4 see label on the rear part Terminal description Power Supply Supply voltage input 0 V Supply voltage input 85 265 Va c Current A phase S
10. s key CKO or C in normal standby status and the meter will show different data in main screen In the menu set mode when changes the parameter and exit setting the meter will ask to SAVE press CAD exit without saving press C save and exit Tel 0086 023 86850812 Email tech cqbluejay com Fax 0086 023 67636974 Add Building 13 2 8 Jialing third village Pioneer Park Jiangbei District Chongqing P R China 9 lt Blue Jay Technology Co Ltd Product Manual 6 SETUP PROCEDURE The SETUP procedure of the BJ193 X is performed by means of several SETUP options Once into the SETUP use the keyboard to select different options and enter required variables 5 f Ta ia USCEL AUSEL jel USEL eel ET _ Set voltage range Input password 3a PASS ma a Fie Era Ce BL Be LI Lt nb Set etn singna CO m CO Pax Ca Co i _ fe eal Sal 7 ae Set CT ratio range is 1 9999 enan i n A n i n rPe peH PE 0001 8000 LRE _ Set PT ratio range is 1 9999 Note The procedure above is for reference not all series have the step 3 communication preference only the K series have this step If you want the X series and D series have this function Menu are not specified in the manual would be invalid do any modify will be no change If doubt about the please contact the Technical Service tech cqbluej