        Manuale utente EMG-USB2
         Contents
1.        0                                                           pag  15          pag  3          pag  4    AEMG User manual v 11          AEMG User manual v 11    Or    1  GENERAL DESCRIPTION    The HEMG is a single channel EMG logger  It has been designed to detect surface  electromyographic  EMG  signals  together with adhesive concentric electrode CoDe    The yEMG allows the detection and recording of the EMG signals generated by human body  The  single differential signal detected by the CoDe electrode is amplified  filtered  digitally converted  and then stored on a MicroSD card  A freeware software called OT BioLab has been designed by  OT Bioelettronica and is available for download on the website www otbioelettronica it  under the    download page     2  HEMG KIT CONTENT     1 amplifier  EMG     6 electrode CoDe     4 reference electrode      LuEMG user manual     3  END USER   The HEMG amplifier allows non invasive recording of single differential electromyographic signals  detected by surface CoDe electrode    The end user must be familiar with the EMG technique and received a proper training in EMG    detection and interpretation     Contraindications    The HEMG is a battery powered device and has no particular contraindications     Side effects  No significant side effects are known  The materials used for manufacturing all the parts in contact  with the patient are biocompatible  Possible slight cutaneous allergic reactions  e g  skin    reddening  are reduce
2. 0 on the entire bandwidth  CMRR  gt  95 dB   1 button    57 x 36x 16mm   25 0        pag  14       EMG User manual v 11    Or    10  WARRANTY   The HEMG is covered by a 24 months warranty starting from the purchasing date of the electronic  parts    The warranty is void in case of device violation or in case of intervention from unauthorized staff     Warranty conditions are reported hereinafter     Warranty conditions  1  The warranty lasts 24 months on the electronic parts  Warranty is provided by the    manufacturer     2  The warranty covers only device damages that cause malfunctioning  The product must have  the same serial number indicated on this certificate  or the warranty is released     3  The warranty covers only the cost of repair or substitutions of defective components  including  the costs of labour     4  The warranty is void in case of damages caused by negligence  use not compliant with the  instructions supplied  unauthorized repairs and accidental circumstances  especially for the  external part     5  The warranty is void with damages caused by incorrect power supply   6  The warranty is not applied on all the parts subject to wear and tear   7  The warranty does not include the shipment costs     8  After 24 months the warranty is released  All the substituted parts  the labour costs and the  shipment costs will be charged to the purchaser according to the rates in force           pag  15          EMG User manual v 11    Designed  produced and distribu
3. Bioelettronica       User manual v 1 1    uEMG    Single channel EMG logger          This product is manufactured in compliance with the European Standard 93 42 CEE about medical  instrumentation  and according to the EN 60601 rules for Medical Electrical Equipment          pag  2    AEMG User manual v 11          EMG User manual v 11    OT    INDEX  1  GENERAL DESCRIPTION                     n  di pag  5  2 PEMG KET CONTENT          a EANN pag  5  2  EINEN pag  5  Contraindications                     pag  5  Side eg pag  5  4                             5                                      5                             55         2      pag  6  5  TECHNICAL SPECIFICATIONS la ada daaa vr aaa aaa   ni oi a ia ia pag  7  6  DETAILED DESORTPT  ON    n LAB a IRR RI  pag  8  Concentric electrode CODE    faves aaa aaa aa aaa dale gelini Galin   ne pag  8  Status edu m   m  n y   E      pag  9  laan BEE pag  9  MicroSD card                     la    el ala pag  9  Electrode Connector            sayan aim nda aram armin aa pag  10  Reference                    NANSENS pag  10  Z  USE OF PEMO          en ee ee pag  11  Performing AN ACQUISILION      vk eege E aa aaa Ae pag  11  Files UE pag  il  Battery replacement        su saa aza      BR          EE ee Eege pag  12  8  EMGMAINTENANCEANDSTORAGE                                     pag  13      TECHNICAL CHARACTERISTICS                      pag  14  10  WARRANTY          ini e  ine               as gal sa   pag  15                 
4. EMG should be stored with all the enclosed accessories on a safe desk far    from all the situations listed in the section Warnings     HEMG should be stored in the following ambient conditions   Temperature  from    20  C to  40  C  Maximum relative humidity  75    Atmospheric pressure  from 700 hPa to 1060 hPa    Cleaning  use only a dry cloth to clean the device     The HEMG should be repaired by the manufacturer only  Every repair executed by unauthorized    personnel will be considered as a device violation voids the manufacturer s warranty     Disposal  The device and the accessories should be disposed in compliance with the relative standards in    special equipped areas or with special waste           pag  13    Or       EMG User manual v 11    9  TECHNICAL CHARACTERISTICS    Model   Classification     Case   Power supply   Consumption     Limitations     Working conditions     Input channels   Amplifier     Commands   Dimensions   Weight        HEMG      battery supplied device    IP50  about the penetration of fluids and dust  device not protected    plastic case  12V MN21 battery  25 mW    the device is not suitable for use in environments with high oxygen  concentration and or flammable fluids and or gases  do not use with  electro surgery or short wave microwave therapy equipment     device suitable for continuative work     1 channel   Maximum input range  3 3 MVpp   Bandwidth  10   500 Hz   Total noise  RTI      3uVems   Gain  980 V V   Input impedance  gt  101
5. ar amplifier  and shows a spatial selectivity comparable with the Laplacian system          pag  8       EMG User manual v 11    Or    which comprises 5 electrodes  Higher selectivity implies a lower amount of crosstalk  which is one  of the main problems in surface EMG recordings     Status led    The led on the yEMG indicate the device status  In table 2 the led condition and the associated    status are described     Led is OFF The yEMG is switched OFF       Led is ON The EMG is in standby  No acquisition is running        Led pulses every 3 seconds The acquisition is running        The battery is low or the MicroSD not correctly formatted  It is not possible  to start an acquisition     Led pulses continuously          TAB  2  UEMG status    Start Stop button   The red button starts or stop the signal acquisition and the data storing on the MicroSD card   When the button is pressed a new file is created on the MicroSD card and is closed when the  button is pressed again  To avoid the creation of large files the EMG automatically close the file  when it reach the dimension of 1 MByte  after about 17 minutes  and open a new file to continue  the data acquisition     A REMARK  Removing the MicroSD card during the signal storing will avoid the file closing  The file not  closed will be displayed  on the PC browser  with a dimension of 0 kByte and it will be not possible to    recover the data     MicroSD card   On the left side of the HEMG there is a slot for the MicroSD inse
6. d to a minimum during short duration electromyographic signal acquisitions           pag  5       AEMG User manual v 11    4  SAFETY CAUTIONS AND OTHER WARNINGS    The use of the HEMG amplifier is forbidden in the following conditions     While electro surgery equipment  short waves or microwaves therapy devices are used    By mentally impaired people    Whenever the equipment is damaged    In proximity of inflammable substances  especially inflammable liquids and gases  or in  environments with high concentration of oxygen    On patients carrying life supporting equipment that might be adversely affected by  electromagnetic interferences  such as pacemakers  etc     The following cautions should be observed        Only use electrodes supplied by the manufacturer  HEMG is guaranteed to achieve tested  performance only if used with electrodes supplied by the manufacturer    Contact the manufacturer immediately if extraneous materials permeate into the device   liquids  powders  etc    In case of hard shocks suffered by the yEMG  like a drop to the floor   etc    verify that no crack or any other kind of damage of the box resulted from the shock  In  case of doubt  please contact the manufacturer    The EMG is subject to electromagnetic interference that is not dangerous for the patient   such as electrostatic or electromagnetic interference generated by electrical motors and other  sources   This interference may affect the measurements of the physiological variables derived  
7. ect the reference electrode or the reference strap to a point without EMG activity on    the subject and connect the clip of the electrode with the clip on the back of the HEMG   2  Place the CoDe on the muscle to investigate and connect the code to the  EMG   3  Insert the MicroSD card in the yEMG slot  the led will turn on    4  Press once the red button to start an acquisition  the led will start to pulse every 3 seconds   5  Press the button again  the led will stop pulses and will turn on   6  Repeat the points 4 and 5 all the times you need   7  Remove the MicroSD card and insert it in a card reader on a PC with OTBioLab installed     8  Open the saved files with OTBioLab and process them     Files details    The files are stored on the memory card with a standard name  The name is structured as follow   UEMG_FXY EMG    Where X is the session counter and Y is the acquisition counter  The acquisition counter is  incremented every time the start stop button is pressed  The session counter is incremented every  time the MicroSD card is removed and then inserted  Since the two characters can assume the  values     1  2    8  9  A  B     Z  it means that up to 36 different files can be acquired in the same  session and 36 different session can be created before to obtain two file with the same name    It is up to the user to copy the files out of the memory card and delete the files in the card to free  the filenames  When a file exist on the memory card and a new one with t
8. from the EMG signal  These measurements are not meant to be used for diagnostic purposes   and thus these signal alterations cannot be dangerous for the patient  please always take into  account the presence of noise in your signal processing tasks and evaluations    The use of the yEMG is restricted to skilled personnel    Incorrect measurements can arise when unskilled personnel use the device in presence of  strong sources electromagnetic interference  e g  strong electromagnetic fields   The presence  of interference in the signals is easily recognised by skilled personnel        pag  6    OT    5  TECHNICAL SPECIFICATIONS       EMG User manual v 11    The HEMG is a battery powered device designed to guarantee an high safety level for the patient     The signal amplified by the instrument is stored in a proprietary file format on a MicroSD card     The HEMG technical specifications are shown in table 1     Signal amplification    Amplification Gain    980 V V       Bandwidth    10 Hz to 500 Hz       Maximum input range    3 3 MV pp       Noise level referred to input     lt  3 uVems       Input impedance     gt 10 lo       CMRR     gt  95 dB       Output range       0 3 3V    Data conversion    A D converter resolution    8 bit       Storage memory    MicroSD       Sample frequency       1 kHz       TAB  1  EMG technical specification       pag  7          EMG User manual v 11    Or    6  DETAILED DESCRIPTION    FIG  1 shows controls  indicators and connectors present on 
9. he same name is  created the file is appended to the existing file    Since the HEMG does not have an internal real time clock device  the date and time of the files will  not reflect the real time in which they are generated  Although  the time and date is generated  starting from the 00 00 of the January 197 2010 and is incremented by 1 minute at every new  acquisition  Sorting the files for the date it is possible to have the file listed in the same order in  which they has been created           pag  11       EMG User manual v 11    Or    Battery replacement   The yEMG works with a 12V battery MN21  The battery allows the acquisition of about 8     9 hours  of EMG signals  When the yEMG led starts to pulse continuously it is necessary to replace the  battery    To replace the battery it is necessary to open the uEMG The yEMG has no screws  just pull the  upper and bottom part of the enclosure  Remove the previous battery and put the new one  Take  care about the battery polarity  The  EMG is not damaged if the battery is inserted in the opposite    way but the battery can lose a large amount of charge        pag  12          EMG User manual v 11    8   EMG MAINTENANCE AND STORAGE    The yEMG has to be used in the following ambient conditions   Temperature  from 0  C to  40  C  Maximum relative humidity  75    Atmospheric pressure  from 700 hPa to 1060 hPa    It is recommended to turn off the  EMG at the end of each measurement session  by removing the  MicroSD card  The y
10. rtion  The MicroSD have to be  inserted vvith its contacts upvvard  In any case it is not possible to insert the card in the opposite  vvay  Push the MicroSD to insert it and push again to release it    The insertion of the MicroSD card switch on the HEMG  Removing the MicroSD card the HEMG is  switched off  Always remove the MicroSD card when the EMG is not used to save the battery           pag  9       EMG User manual v 11    Or    The MicroSD card must be formatted with standard FAT  Formatting the card as FAT32 or NTFS  the instrument will not work and the led will pulse continuously to indicate the malfunction      N REMARK  Use only MicroSD card  The HC version will not work with the HEMG     Electrode connector  The CoDe electrode have to be connected at this circular connector  The portion of cable between  the HEMG and the electrode connector is shielded to reduce interference coupling     Reference clip   On the back side of the HEMG a clip connector has a double function  The primary function is to fix  the voltage reference on the patient  the second is to keep mechanically the EMG without the  need of tapes  It is possible to use a common electrode or a reference strap to electrically connect  the HEMG internal reference point with a point on the patient without EMG activity  e g  the ankle  or the wrist            pag  10       EMG User manual v 11    7  USE OF pEMG    Performing an acquisition  To perform an acquisition follow the steps reported here   1  Conn
11. ted by     OT Bioelettronica    C so Unione Sovietica 312  10135   Torino  TO    ITALY  Tel  39 011 6198498  Fax  39 011 6198498  URL  www otbioelettronica it  e mail  mail otbioelettronica it       pag  16    
12. the HEMG and described in the    following sections                          Concentric electrode CoDe         Ki Status led       Start Stop button   4  MicroSD card      Electrode connector     Reference clip       FIG  1  UFMG description    Concentric electrode CoDe   The CoDe  Concentric Detection  is an adhesive disposable concentric electrode distributed by OT  Bioelettronica  The CoDe electrode allows the detection of surface myoelectric signals  The  geometry of the system  a point electrode and a circular ring  avoids the problem of the  orientation of classic bipolar recordings  Moreover  the system transfer function approximates a  double differential filter which thus provides better spatial selectivity and better reduction of  crosstalk with respect to bipolar systems  The electrode is available in different sizes  depending  on the specific application  The detection site is made of AgCI and the electrode connector types  can be mounted depending on the needs    The CoDe electrode is the only system purely isotropic  that is invariant to rotations  Other  systems  such as the Laplacian recording  approximate the isotropic condition but do not fulfill it   The isotropy eliminates the problem of electrode orientation  In addition  the system provides a  two dimensional spatial filtering with selectivity similar or higher than other systems with larger  number of electrodes  The proposed system only uses two electrodes  thus it can be used with any  standard bipol
    