1. keys to select the level of the display intensity and press Enter to confirm or Mode to cancel and return to the menu Display reverse With this function you can rotate the display by 180 Use the Up and Down keys to select normal display or display turned by 180 and press Enter to confirm or Mode to cancel and return to the menu Display On This function allows you to keep the display On or to turn Off automatically 2 minutes after last pressing any key on the control board Use the Up and Down keys to select On if you wish to keep the display On or Off if you wish to turn Off automatically 2 minutes after last pressing any key on the control board and press Enter to confirm or Mode to cancel and return to the menu 17 PAN TILT feedback This function allows to return the mowing head to the required position after changing the position by external force e g by stroke Use the Up and Down keys to select On if you wish to anable this function or Off if you wish not to return the mowing head to the required position and press Enter to confirm or Mode to cancel and return to the menu Note If feedback was switched Off the pan tilt position is changed by external force and feedbeck is switched On again the moving head might not to be synchronized with the DMX signal You have to make a reset in order to synchronize the moving head with the DMX signal Lamp Off via DMX This function al
2. Channel 3 Vertical head movement 8 bit Channel 4 Fine Vertical head movement 16 bit Channel 5 Pan Tilt speed Channel 6 Fan speed On Off lamp reset Channel 7 Colours Channel 8 Cyan Channel 9 Magenta Channel 10 Yellow Channel 11 Speed of CMY and dimmer Channel 12 Colours macros Channel 13 Effect wheel Channel 14 Zoom Channel 15 Shutter strobe Channel 16 Dimmer Pan Tilt Pan movement range 530 Tilt movement range 280 8 16 bit movement resolution Automatic Pan Tilt position correction Maximum PAN movement 530 in 2 65 s Maximum TILT movement 280 in 1 68 s Rigging Stands directly on the floor Mounts horizontally or vertically with 2 clamps 2 truss orientation Safety chain cord attachment bolt Dimensions and weight Length of base including handles 467mm Width of yoke Height head horizontal Weight net Shipping weight 582 563 TE 0000000000 0000000000 x 144 I ct I Ut Temperatures Maximum ambient temperature t 40 C Maximum housing temperature f steady state 80 C 11 Maintenance and cleaning The operator has to make sure that safety relating and machine technical installations are inspected by an expert after every four years in the course of an acceptance test The operator has to make sure that safety relating and machine technical inst
3. by step these messages PAn Tilt SPEd Colo CYAn MAGE YELL MACr EFEC Zoom Siro dimr FCAL by which you can adjust the fixture to the required desired position 0 255 before the function calibration Then when the positioning is finished use the last FCAL function Fixture calibration 19 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 1 Calibration via the control board Press Enter and the Up and Down keys in order to display the following messages Colo EFEC for very smooth function calibration Select one of them press Enter and use the Up and Down keys in order to adjust their right value from 0 to 255 Then press Enter to confirm or Mode to cancel and return to the menu This can be repeated for each calibration parameter if itis required When the calibration is finished it is necessary to use the ArES function in order to write the calibration values to the memory EPROM and to make a reset in order to check the newly adjusted positions of the colour and the effect wheel When the reset of the fixture is finished the display will show the FCAL message Press Enter to repeat the calibration or Mode to return to the AdJ menu 2 Calibration via the external controller Press Enter and the Up and Down keys in order to display the following messages Colo EFEC calibration parameters Select one of them and press Enter Now you can calibrate t
4. 4 3 2 o1 o 5 0 M amp 1 E2 a 3 4 o 5 10 15 20 Distance m 0 5 10 15 20 Distance m 0 62 1 22 1 83 2 45 Diameter m 0 2 49 4 99 7 47 9 97 Diameter m Distance 5m 24000 l 7 radiation angle 18000 x gt 12000 6000 ZH TT 28 radiation angle o EE RE ET 1 0 0 8 0 6 0 4 0 2 0 02 0 4 0 6 0 8 1 0 Diameter m Colours CMY colours mixing system 4 dichroic colour filters plus white colour temperature filters 3200 K and 5600 K UV filter Colour wheel with variable rotation speed in both directions Strobe Strobe effect with variable speed 1 10 flashes per second Dimmer Smooth dimmer from 0 100 96 Zoom Remotely controllable via DMX Motorized multi step zoom between 7 and 28 beam angles Effects Beam shaper Frost filter Motors 13 high quality stepping motors controlled by microprocessors 22 Electronics Addressing special functions setting effects calibration via control panel with 4 digit LED display Readout fixture and lamp usage receiving DMX values temperature etc Built in analyzer for easy fault finding error messages Remotely switching of the lamp Bilt in demo sequences Black out while head moving or color changing Silent fans cooling remotely controllable speed of fans Self resetable thermo fuse Digital serial input DMX 512 16 control channels full 16 bit protocol Channel 1 Horizontal head movement 8 bit Channel 2 Fine Horizontal head movement 16 bit
5. Orange proportional CTF 3200 K proportional CTF 5600 K proportional UV filter proportional Forwards rainbow effect from fast to slow proportional No rotation step Backwards rainbow effect from slow to fast proportional Cyan 0 255 Cyan 0 white 255 full cyan proportional Magenta 0 255 Magenta 0 white 255 full magenta proportional Yellow 0 255 Yellow 0 white 255 full yellow proportional Speed of CMY and Dimmer 0 255 From max speed to min speed proportional Colours macros CMY and colour wheel Off Macro 1 Macro 2 Macro 3 Macro 4 hannel Channel Value Type of control 16 bit 8 bit Macro 5 Macro 6 Macro 7 Macro 8 Macro 9 Macro 10 Macro 11 Macro 12 Macro 13 Macro 14 Macro 15 Macro 16 Macro 17 Macro 18 Macro 19 Macro 20 Macro 21 Macro 22 Macro 23 Macro 24 Macro 25 Macro 26 Macro 27 Macro 28 Macro 29 Macro 30 Macro 31 Effect wheell 0 70 Full beam step 71 180 Beam shaper proportional 181 255 Frost filter proportional proportional Shuter strobe Shutter closed step Shutter open step Strobe effect from slow to fast max 10flashes s proportional Shutter open step Pulse effect in sequences proportional Shutter open step Random strobe effect proportional Shutter open step Dimmer intensity Gradual adjustment of the dimmer intensity proportional from 0 to 10096 11 6 Addressing The control board on the front panel of the ServoColor 575 allows you to assign the DMX fixtu
6. Rear panel Power switch DMX output DMX input Power cord Fuse holder 10 O1 Front panel 10 Mode button 11 Enter button 12 Up button 13 Down button 14 Display 4 Installation 4 1Fitting the lamp DANGER Install the lamps with the device switched off only Unplug from mains before To insert the lamp OSRAM HSR 575 2 95 V 575 W GX 9 5 or PHILIPS MSR 575 2 95 V 575 W GX 9 5 MSD 575 95 V 575 W GX 9 5 open the small cover at the head s rearpanel see the drawing by loosening the 3 Phillips screws X Y and Z on the cover Gently pull out the lamp assembly If changing the lamp remove the old lamp from the socket Insert the lamp to the socket Do not install a lamp with a higher wattage A lamp like this generates temperatures the device is not designed for Damages caused by non observance are not subject to warranty Please follow the lamp manufacturer s notes Do not touch the glass bulb bare handed during the installation Make sure that the lamp is installed tightly into the lampholder system Reinsert the lamp assembly and tighten the 3 screws again Before striking the lamp reset the LAti counter in the main menu of the Control Board by pressing the Up and Down buttons in one time and then confirming with the Enter button Lamp assembly Lamp cover Remove the screws X Y and Z for re lamping WARNING Disconnect the fixture from AC power before re lamping Lam
7. SERVUCOLOH 5 5 auromoated lign system USER MANUAL Copyright Version 1 0 SERVO COLOH 5 5 oaurometregd lianr system Table of contents 1 Safety INSIFUCIIONS nina ne 3 2 Operating determinations nn nn Re asus 4 3 Description of the devIGB ss sassnnnesisennnnansnnsienanerannnsstsennnrenninsasauns 5 A Installati n Meer Y 6 4 1Fitting the lamp NE om 6 4 2 Lamp adjustment LS nn nn ene de RE 7 4 3 Rigging the fixture ace ost RR 7 4 4 Connection to the mains iii 9 4 5 DMX 512 connection connection between fixtures sssssssseeeeseess 9 5 DMX PROTOCOL 5 5 akkxai eukuxi Dra sal ra uie Leu cu ch rra Ec qY Dr AX di d ca CUI ret V iw eL X dra aa d 10 B Addressing st a Gate 12 7 Remotely controllable functions vsscsinssisacctscsicacssenacnnnserdasassasensaseccssubscannanaccensessdasenscane 12 AN AMD a Ne 12 7 2 Switching On and Off the lamp by the control board 12 7 SOLU WINGS I M L 12 7 4 CMY colours mixing SVSIOfTI 1 acc o GERI REMIS ERR oa E LIE PETERS ne 13 T0 AO ANT CN c E UU T LT 13 TG SSMU SR SOS ar es Hit nes erue E OD ab ELM 13 Vaso M 13 70 al B59 aie SE EI MI IL DUM ID II rere eter tre 13 T9 e 13 8 Control Board ann Em 13 8 1 Main fUNCHONS D aadi a iada ESNA 13 8 2 SPEC SPeCCial MUNCH ONS dd ni nn 15 9 Err
8. allations are inspected by a skilled person once a year The following points have to be considered during the inspection 1 All screws used for installing the devices or parts of the device have to be tighly connected and must not be corroded 2 There must not be any deformations on housings fixations and installation spots ceiling suspension trussing 3 Mechanically moved parts like axles eyes and others must not show any traces of wearing e g material abrading or damages and must not rotate with unbalances 4 The electric power supply cables must not show any damages material fatigue e g porous cables or sediments Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed DANGER TO LIFE Disconnect from the mains before starting any maintenance work It is absolutely essential that the fixture is kept clean and that dust dirt and smoke fluid residues must not build up on or within the fixture Otherwise the fixture s light output will be significantly reduced Regular cleaning will not only ensure the maximum light output but will also allow the fixture to function reliably throughout its life Please use a moist lint free cloth Never use alcohol or solvents The front objective lens will require weekly cleaning as smoke fluid tends to building up residues reducing the light output very quickly The cooling fans should be cleane
9. and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation The installation must always be secured with a secondary safety attachment e g an appropriate catch net This secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main attachment fails When rigging derigging or servicing the fixture staying in the area below the installation place on bridges under high working places and other endangered areas is forbidden The operator has to make sure that safety relating and machine technical installations are approved by an expert before taking into operation for the first time and after changes before taking into operation another time The operator has to make sure that safety relating and machine technical installations are approved by an expert after every four year in the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are approved by a skilled person once a year The projector should be installed outside areas where persons may walk by or be seated IMPORTANT OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE including but not limited to calculating working load limits installation material being used and periodic safety inspection of all installation material and the projector If you lack these qualifications do not attempt the installation yourself but instead use a p
10. controller directly with the DMX input of the first fixture in the DMX chain If you wish to connect DMX controllers with other XLR outputs you need to use adapter cables Building a serial DMX chain Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture Always connect one output with the input of the next fixture until all fixtures are connected Caution At the last fixture the DMX cable has to be terminated with a terminator Solder a 120 Ohm resistor between Signal and Signal into a 3 pin XLR plug and plug it in the DMX output of the last fixture 5 DMX PROTOCOL hannel Channel Value Type of control 16 bit 8 bit Pan movememtbysaoe EI 255 Pan movement Pan movememtbysaoe 530 m Pan fine 0 255 Fine control of pan movement proportional Tilt 0 255 Tilt movement by 280 mom Tilt fine 0 255 Fine control of tilt movement proportional Speed of PAN TILT movement Max speed tracking mode step From max speed to min speed vector mode proportional Max speed track mode black out while color step changes Max speed vector mode black out while pan tilt step moving or color changes Lamp on off reset fans speed control From max speed of fan to min speed of fan proportional Lamp on reset step No function step Lamp off after 3 sec step No function step Colours Open white proportional Deep red proportional Blue proportional Green proportional
11. d monthly The interior of the fixture should be cleaned at least annually using a vacuum cleaner or an air jet The dichroic colour filters the CMY wheels and the internal lenses should be cleaned monthly There are no serviceable parts inside the device except for the lamp and the fuse Maintenance and service operations are only to be carried out by authorized dealers Replacing the fuse If the lamp burns out the fine wire fuse of the device might fuse too Only replace the fuse by a fuse of same type and rating Before replacing the fuse unplug mains lead Procedure 1 Unscrew the fuseholder on the rear panel with a fitting screwdriver from the housing anti clockwise 2 Remove the old fuse from the fuseholder 3 Install the new fuse in the fuseholder 4 Replace the fuseholder in the housing and fix it 12 Appendix We believe you will enjoy your ServoColor 575 We assure you will enjoy this product for years if you follow the instructions given in this manual If you have any questions and comments please do not hesitate to contact us Please note errors and omissions for every information given in this manual excepted Every information is subject to change without prior notice Any claim due to missing or wrong information in this manual is herewith excluded 24
12. ed off until it has reached room temperature This device falls under protection class The power plug must only be plugged into a protection class outlet Never let the power cord come into contact with other cables Handle the power cord and all connections with the mains with particular caution Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged by sharp edges Check the device and the power cord from time to time Always disconnect from the mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord During the initial start up some smoke or smell may arise This is a normal process and does not necessarily mean that the device is defective Caution During the operation the housing becomes very hot Do not switch the device on and off in short intervals as this would reduce the lampss life CAUTION EYEDAMAGES Avoid looking directly into the light source meant especially for epileptics Please consider that damages caused by manual modifications to the device are not subject to warranty Keep away children and amateurs 2 Operating determinations This device is a moving head spot for creating decorative effects and was designed for indoor use only This device is designed for professional use e g on stages in discotheques theatres e
13. eed of the fan operating The fan keeps the adjusted low speed until the temperature exceeds max inside temperature of the fixture then the ServoColor 575 automatically switch from low to high the fan speed Oo LL 04 LJ continuous controlling of the fan speed without the DMX value This mode is similar to reG but the initial level of fan speed can t be adjusted by the DMX Default settings Press Enter to reset all fixture personalities not the adjusting functions to the default values On the display will appear rSt meaning that the fixture makes the reset See the table of personality setting and their default positions Personality Display Default values SHADED 5 Gn Pan reverse nt PH 1 OFF L IL On Tilt reverse t LIIL OFF 1 CL _ Ga Movement resolution OO DEF Lamp On after switch m_m On the fixture On Out OFF witch On Off c On the lamp light sensor eri OFF n Display On d Ga un OFF Display intensity cC int 8858 sopo f Eurn Display reverse curn MATE CCC Un PAN TILT feedback FEES EE n onc On Lamp Off via DMX OL LI DEE Ruto ib Low fan speed E Hn5 rez operating LoUF Lol Adjusting the default positions of colour and effect wheels By this function you can calibrate and adjust the colour and CMY to their standard right positions Use the Up and Down keys to browse through the adjusting menu the display shows step
14. er is switched off or defective if the cable or connector is defective or the signal wires are swap in the input connector Note It s necessary to insert the XLR termination plug with 120 Ohm in the last lighting in the link in order to ensure proper transmission on the DMX data link 7 Remotely controllable functions 7 1 Lamp The ServoColor 575 is to be operated with a OSRAM HSR 575 2 95 V 575 W GX 9 5 or PHILIPS MSR 575 2 95 V 575 W GX 9 5 MSD 575 95 V 575 W GX 9 5 lamp A relay inside of the ServoColor 575 allows you to switch on and off the lamp via the Control Board on the front panel or via your controller without affecting the rest of the lighting 7 2 Switching On and Off the lamp by the control board 1 Switch On the ServoColor 575 and wait until the fixture reset has finished 2 Press the Mode key in order to access the main menu Browse through the menu by pressing the Up and Down keys until the display shows LAMP Confirm by pressing Enter key 3 Use the Up and Down keys to select On for switch On the lamp and Off for switch Off the lamp and press Enter to confirm or Mode to cancel Note It is also important to note that the discharge lamp is cold restrike types that means that they have to be cold before re striking For this reason you have to wait 5 minutes max speed of fan must be adjusted after having switched Off the lamp before you can switch it back On again If you try to switch On t
15. ervoColor 575 is cooled by three axial fans two in the projector head and one in the base The speed of the fan and of course the noise can be continuously reduced if very quiet performance is required By the Control Board using the FAnS function you can choose 5 types of low fan speed operating 1 HIGH high max speed of fans The cooling fans work on max speed max cooling 2 rEG continuous controlling of the fan speed the fan automatically raises its speed in order to control inside temperature of the lighting if the temperature inside increases about certain level the low fan speed reduces the cooling of the lighting This cycle can repeat several times until the temperature inside is on suitable level 3 Lo OF low speed Switch Off the lamp operating the fan keeps the adjusted low speed until the temperature exceeds max inside temp Then the ServoColor 575 automatically switch Off the lamp 4 Lo HI low high speed of the fan operating the fan keeps the adjusted low speed until the temperature exceeds max inside temp of the fixture then the ServoColor 575 automatically switch from low to high the fan speed 5 Auto continuous controlling of the fan speed without the DMX value This mode is similar to reG but the initial level of the fan speed can t be adjusted by the DMX 8 Control Board The control board situated on the front panel of the ServoColor 575 offers several features You can simply set the lighti
16. he colour and the effect by your controller The DMX calibration protocol is described in the table DMX Calibration protocol Dmx chanel Function SSS o E p p oe momen ee D D O ON 3 3 D 3 D lt O O 3 20 After having calibrated required functions press Enter to confirm or Model to cancel and return to the menu without reset by the ArES function and use the ArES function in order to write the calibration values to the memory EEPROM and to make a reset in order to check the new adjusted positions of the colour and effect wheel 9 Error and information messages HEAt This message appears if you try to switch on the lamp within 5 minutes after having switched it off the lamp is too hot The message will appear on the display if the lamp doesn t ignite within 28 seconds The ServoColor 575 will store this information and automatically ignite the lamp when the 5 minutes period has expired Caution The message is disabled if the lamp light sensor function EnSn is switched Off only if the lamp was turned Off and On within 5 minutes the message HEAt will appear LAEr The ignition of the lamp is seven times unsuccessful the HEAt message appeared six times before and the display shows LAEr meaning that the lamp could be damaged or even missed the fixture is overheating this can occur if the ambient temperature is 40 C or more or there could be a failure on the ignitor or ballast Please p
17. he lamp within 5 minutes after having switched it Off the ServoColor 575 will store this information and automatically ignite the lamp when the 5 minutes period has expired The message HEAt will appear on the control board display of the ServoColor 575 If the ignition of the lamp is seven times unsuccessful on the display will appear LA Er meaning that the lamp could be damaged or even missed or there could be a failure on the ignitor or ballast 7 3 Colour wheel The ServoColor 575 features a colour wheel with 8 color positions 4 of these with dichroic colors hot and cold colour temperature filters 3200K and 5600K UV filtr and the last one open It is also possible to rotate the color wheel continuously at different speeds Rainbow effect in both directions 7 4 CMY colours mixing system The CMY color mixing system is based on graduated cyan magenta and yellow color filters continuous range of colors may be achieved by varying the amount of each filter from 0 to 100 7 5 Beam effects The beam shaper allow you to widen and flatten beam Beam shaper rotates 180 Frost filter on the same wheel as beam shaper softens the beam 7 6 Shutter strobe Extremely fast shutter may also be used for strobe effect 1 10 flashes per second 7 7 Zoom Motorized zoom unit enables the beam to be zoomed between 7 and 28 beam angle 7 8 Dimmer Smooth 0 100 dimming is provided by special dimmer unit 7 9 Fan The S
18. is hot Risk of fire Protect hands and eyes Wait at least 15min before opening the covers Adjust lamp position by turning screws A B and C 3 phillips screws X Y Z Do not operate this fixture with opened housing cover 4 2 Lamp adjustment Remove the screws X Y and Z for re lamping WARNING Disconnect the fixture from AC power before refamping 3 adjustment screws A B C The ServoColor 575 lampholder is aligned at the factory Due to differences between lamps fine adjustment may improve light performance Strike the lamp open the shutter and the iris set the dimmer intensity onto 100 96 and focus the light on a flat surface wall Center the hot spot the brightest part of the beam using the 3 adjustment screws A B C Turn one screw at a time to drag the hot spot diagonally across the projected image If you cannot detect a hot spot adjust the lamp until the light is even To reduce a hot spot pull the lamp in by turning all three screws A B C clockwise 14 turn at a time until the light is evenly distributed If the light is brighter around the edge than it is in the center or if light output is low the lamp is too far back in the reflector Push the lamp out by turning the screws A B C counterclockwise 4 turn at a time the light is bright and evenly distributed 4 3 Rigging the fixture The installation of the projector has to be built
19. lace or replace the lamp check the ambient temperature or contact your dealer if the situation was not caused by the lamp Caution The message is disabled if the lamp light sensor function EnSn is switched Off FAn The message informs you that the fixture was overheating and the lamp was switched off This message will appear on the display if the fan speed operating LOOF is selected MbEr This messsage informs you that the main PCB does not communicate correctly with the Control Board CoEr color wheel error This messsage will appear after the reset of the fixture if the magnetic indexing circuit malfunctions sensor failed or magnet missing or the stepping motor is defective or its driver circuit on the main PCB The color wheel is not located in the default position after the reset FtEr The message informs you that the fixture was overheating occured if the ambient temperature is 40 C or more and that the relay switched off the lamp This message will appear on the display until the temperature will be on a suitable level then the display will show the HEAt message meaning the lamp is too hot SnEr This message appears if the lamp lighting sensor is failed Please contact your dealer Caution The message is disabled if the lamp light sensor function EnSn is switched Off PoEr This message will appear if the fixture was shortly disconnect from the main PAEr PAN yoke movement error This message will appear af
20. lows you to switch Off the lamp by DMX Use the Up and Down keys to select On if you want to switch Off the lamp by DMX or Off if you don t want to switch Off the lamp by DMX and press Enter to confirm or Mode to cancel and return to the menu Temperature Temperature readouts of fixture inside in Celsius Inside temperatures below 80 C are not critical 80 C and more lead to the lamp being switched off Please note that the outside temperature should not exceed 40 C Low fan speed operating By using this function you can choose 5 types of low fan speed operating Browse through this menu by the pressing Up and Down keys the display shows step by step these messages HIGH reG Lo OF Lo HI Auto Press Enter if you wish to select one of them or Mode to cancel and return to the menu high max speed of fans The cooling fans work on max speed max cooling continuous controlling of the fan speed The fan automatically raises its speed in order to control inside temperature of the lighting if the temperature inside increases about certain level the low fan speed reduces the cooling of the lighting This cycle can repeat several times until the temperature inside is on suitable level 18 low speed Switch Off the lamp operating The fan keeps the adjusted low speed until the temperature exceeds max inside temperature of the fixture then the ServoColor 575 automatically switch Off the lamp low high sp
21. menu Switch On Off the lamp light sensor Use the Up and Down keys to select On if you wish to switch the lamp light sensor On and press Enter to confirm or Mode to cancel and return to the menu The option On is for the standard operation Use the Up and Down keys to select Off if you wish to switch the lamp light sensor Off and press Enter to confirm or Mode to cancel and return to the menu Important The option Off is for emergency operation only if the lamp light sensor is defective and you will wait for a delivery of the spare light sensor If the lamp light sensor was switched Off the error messages LAEr SnErHEAt will not appear on the display only the message HEAt will appear if the lamp was turned Off and On within 5 minutes and at switching On of the lamp the electronics will still try to ignite the lamp until it shines even when the lamp is damaged or absent on this account some electronics parts could be damaged 16 DMX values Readout DMX values of each channel received by the fixture Use the Up and Down keys to select desired channel and press Enter to read its value coming to the fixture or Mode to cancel and return to the menu 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 This function allows you to adjust the display settings Display intensity With this function you can adjust the display intensity from 20 to 100 Use the Up and Down
22. n 8 or 16 bit Use the Up and Down keys to select On if you wish the 16 bit high resolution or Off if you wish only 8 bit resolution and press Enter to confirm or Mode to cancel and return to the main menu Note If you adjust the 16 bit resolution the fixture will occupy 16 DMX channels if you adjust the 8 bit resolution the fixture will be operated by only 14 DMX channels Please check the DMX protocol Lamp On time This option enables you to read the total number of hours that the lamp has been powered On Press Enter or Mode to return to the main menu In order to reset the counter to 0 you have to hold the Up and Down button and press the Enter button Power On time By this option you can read the total number of hours that the ServoColor 575 has been powered On Press Enter or Mode to return to the main menu Switch On Off the lamp Use the Up and Down keys to select On if you wish the switch On the lamp or Off if you wish switch Off the lamp and press Enter to confirm or Mode to cancel and return to the main menu 14 Demo sequences This function allows you to run a special demo test sequences without an external controller which will show you some possibilities of using ServoColor 575 Press Up and Down keys to select the Mod1 or Mod2 sequences The Mod1 is suitable for projections on the wall ceiling or ground without any head movement the Mod2 uses all ServoColor 575 f
23. ng address read the number of lamp or unit hours switch On and Off the lamp run test show make a reset and also use special functions for manual demo and service purposes 8 1 Main functions The main menu is accessed by pressing the Mode key press this one so many times until the display shows message A001 with actually stored address Browse through the menu by the pressing Up and Down keys the display shows step by step these messages A001 rPAn rTilt 16br Lati Poti LAMP dEMo rESE SPEC Press Enter if you wish to select one of them The functions are described in the following sections and the function hierarchy is shown below 13 DMX 512 Address settings The letter A flashes Use the Up and down keys to select required address 001 497 and press Enter to confirm or Mode to cancel and return to the main menu Pan reverse This function allows you to invert the pan movement Use the Up and Down keys to select On if you wish this feature or Off if you don t wish this feature and press Enter to confirm or Mode to cancel and return to the main menu Tilt reverse This function allows you to invert the tilt movement Use the Up and Down keys to select On if you wish this feature or Off if you don t wish this feature and press Enter to confirm or Mode to cancel and return to the main menu Movement resolution By this function you can adjust the desired movement resolutio
24. or and information messages eeeeeeeeeeeeeeeeeeeeeeenseeeeeeeeeeeeeeeeseeeeeeeeeeeeeeneeeeees 21 10 Technical specifications nn aa en 22 11 Maintenance and cleaning sa isisinindicissiisicscsstcanansscesssnsnsdansasudcusisdesadauedannsesdsanendaanadanieans 24 QM ep qm sd naasna ae use aoaaa aidaa Kanarian Sao Neee 24 CAUTION Keep this device away from rain and moisture Unplug mains lead before opening the housing FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOU INITIAL START UP 1 Safety instructions Every person involved with installation and maintenance of this device have to be qualilfied follow the instructions of this manual Caution Be careful with your operations With a a dangerous voltage you can suffer a dangerous electric shock when touching the wires This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual Important Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems If the device has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your device Leave the device switch
25. re address which is defined as the first channel from which the ServoColor 575 will respond to the controller If you set for example the address to channel 5 the ServoColor 575 will use the channel 5 to 20 for control Please be sure that you don t have any overlapping channels in order to control each ServoColor 575 correctly and independently from any other fixture on the DMX data link If two three or more ServoColor 575 are addressed similarly they will work similarly For address setting follow this procedure 1 Switch On the ServoColor 575 and wait until the fixture reset has finished rSt is flashing at the display 2 Press the Mode key in order to access the main menu Browse through the menu by pressing the Up and Down keys until the display shows A001 Confirm by pressing Enter key and the letter A will flash 3 Use the Up and Down keys to select the desired address 4 Confirm by pressing Enter or Mode to cancel Controlling After having addressed all ServoColor 575 you may now start operating these via your lighting controller Note After switching on the ServoColor 575 will automatically detect whether DMX 512 data is received or not If there is no data received at the DMX input the display will start to flash A001 with actually set address This situation can occur if the 3 PIN XLR plug cable with DMX signal from controller is not connected with the input of the device the controll
26. rofessional structural rigger Improper installation can result in bodily injury and or damage to property The projector has to be installed out of the reach of people If the projector shall be lowered from the ceiling or high joists professional trussing systems have to be used The projector must never be fixed swinging freely in the room Caution Projectors may cause severe injuries when crashing down If you have doubts concerning the safety of a possible installation do NOT install the projector Before rigging make sure that the installation area can hold a minimum point load of 10 times the projector s weight Danger of fire When installing the device make sure there is no highly inflammable material decoration articles etc in between a distance of min 0 5 m CAUTION Use 2 appropriate clamps to rig the fixture on the truss Follow the instructions mentioned at the bottom of the base Make sure that the device is fixed properly Ensure that the structure truss to which you are attaching the fixtures is secure The Moving head can be placed directly on the stage floor or rigged in any orientation on a truss without altering its operation characteristics see the drawing The fixture s base enables to be mounted in two ways Use the clamps with screws M10 or M12 check the base bottom For overhead use always install a safety rope that can hold at least 10 times the weight of the fixture You must only use safety
27. ropes with screw on carabines Pull the safety rope through the eye bolt on the bottom of the base and over the trussing System etc Insert the end in the carabine and tighten the fixation screw XXX XXX XX TX CN LXX i 3 XX X2 NDO Mounting plate Secure chain 4 4 Connection to the mains Connect the fixture to the mains with the enclosed power plug The earth has to be connected The occupation of the connection cables is as follows Cable Pin international Brown Live Blue Neutral Yellow Green Earth 4 5 DMX 512 connection connection between fixtures The wires must not come into contact with each other otherwise the fixtures will not work at all or will not work properly ui lt DWX 512 Only use a stereo shielded cable and 3 pin XLR plugs and connectors in order to connect the controller with the fixture or one fixture with another Occupation of the XLR connection DMX output DMX input XLR mounting socket XLR mounting plug 1 Ground 1 Ground 2 Signal 2 Signal 3 Signal 3 Signal If you are using the standard controllers you can connect the DMX output of the
28. tc Lighting effects are not designed for permanent operation Consistent operation breaks will ensure that the device will serve you for a long time without defects Never run the device without lamp Do not shake the device Avoid brute force when installing or operating the device Never lift the fixture by holding it at the projector head as the mechanics may be damaged Always hold the fixture at the transport handles When choosing the installation spot please make sure that the device is not exposed to extreme heat moisture or dust There should not be any cables lying around You endanger your own and the safety of others The minimum distance between light output and the illuminated surface must be more than 1 meter Make sure that the area below the installation place is blocked when rigging derigging or servicing the fixture Always fix the fixture with an appropriate safety rope Fix the safety rope at the correct holes only Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened The lamp must never be ignited if the objective lens or any housing cover is open as discharge lamps may explose and emit a high ultraviolet radiation which may cause burns The maximum ambient temperature t must never be exceeded CAUTION The lens has to be replaced when it is obviously damaged so that its function is impaired e g due to cracks or deep scratches Operate
29. ter the reset of the fixture if the yoke s magnetic indexing circuits malfunction sensors failed or magnet missing or the stepping motor is defective Or its driving IC on the main PCB The yoke is not located in the default position after the reset tiEr TILT head movement error This message will appear after the reset of the fixture if the head s magnetic indexing circuit malfunctions sensor failed or magnet missing or the stepping motor is defective Or its driving IC on the main PCB The head is not located in the default position after the reset FrEr It will appear if the frequency of the mains is not standard 50 or 60Hz 21 10 Technical specifications Power supply EU model 208 230 240 V AC 50 60 Hz FUSE cod e a us T 5 0AQ 230 V US model 100 115 208 230V AC 50 60 Hz FUSE on eder es T10A 115V Power consumption 850 VA Lamp OSRAM HSR 575 2 95V 575W GX 9 5 750h PHILIPS MSR 575 2 95V 575W GX 9 5 750h or MSD 575 95V 575W GX 9 5 2000h Optical System High luminous efficiency parabolic reflector Zoom 7 28 Fresnel lens of diameter 200 mm All lenses are anti reflection coated Beampath Beam angle 7 min zoom Beam angle 28 max zoom 22850 5710 2540 1430 LUX 6210 1550 690 390 LUX
30. the device only after having familiarized with its functions Do not permit operation by persons not qualified for operating the device Most damages are the result of unprofessional operation CAUTION The lamp has to be replaced when it is damaged or deformed due to the heat Please use the original packaging if the device is to be transported Please consider that unauthorized modifications on the device are forbidden due to safety reasons Never remove the serial barcode from the device as this would make the guarantee void If this device will be operated in any way different to the one described in this manual the product may suffer damages and the guarantee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock burns due to ultraviolet radiation lamp explosion crash etc 3 Description of the device D 10 8 SEROK GEOR 8888 epon wg dn ee EE D ie 11 42 13 1 Projector head 2 Yoke 3 Carrying handles 4 Base
31. unctions and therefore is good for a complete introduction of the fixture 0 255 0 255 0 255 run Reset Function Press Enter key to run reset This option enables the ServoColor 575 to index all effects functions and return to their standard positions 8 2 SPEC Special functions Use the Up and Down keys to browse through the special functions and select the one by pressing Enter 15 Manual control of effects This function allows you to control manually the channel functions of the fixture Use the Up and Down keys to select desired function and press Enter to adjust the effect or Mode to cancel and return to the menu Lolo E L P n titi SPdi Co O CYRO NACO YELO CSP OFF HOLE Zoo OPEn dinl PAn Elt SPde Co CUR NAGI YELI CSP NA SHAI oo Str din PAnJ tit SPd3 Co e CYR MAGE YELe CSP3 NA 2 SHRP 2oo3 5Pg4 Coot SkrS din SPd5 to 9 CYAS NACS SELS CSPS NAID SHAR di nt Fros Lamp On automatically This menu allows you to turn the lamp On after switching the fixture On and switch On Off the lamp light sensor Poln Lamp On after switching the fixture On This function enables to turn the lamp On automatically after switching the fixture On Use the Up and Down keys to select On if you wish to turn the lamp On automatically after switching the fixture On or Off if you wish the lamp Off after switching On the fixture and press Enter to confirm or Mode to cancel and return to the