Home
Connecting the detector directly to a printer through the
Contents
1. GB 00981 Edition 04 December 01 Purpose of the printer interface Location of the printer interface I RARAY o ar aa a a A a B 40 Connecting the detector directly to a printer through the RS 232 interface The Printer RS 232 interface makes it possible to connect the leak detector to a printer of parameters memorized in the leak detector the ticket doesn t give the test results see example of ticket next page On the ticket printed you will find all the values It is a Sub D 9 pin Male connector located on the side of the leak detector ASM 192T2D ASM 182TD 3e 4o 5e 69 79 30 90 Pin Function Communication protocol NA Mode Asynchronous 2 Rx Bauds 9600 3 Tx Bits 8 4 NA Parity None 5 Ground Stop bit 6 NA Parity control None Z RTS 8 CTS A Alcatel s use only Don t connect it Communication mode Configuration tickets are sent out description Connection to the printer Leak detector Printer serial port Alcatel Vacuum Technology France ASM 182 TD ASM 192 T2D User s Manual 2 B 40 Connecting the detector directly to a printer through the RS 232 interface Example of ssv 27 cowscvetion stones a configuration ticket DATE Jan 01 2001 TIME 00 00 49 SET POINTS MENUS audio level 3 digital voice level 4 hard vacuum alarm fixed hard vacuum reject point 1 0E 07 sniffing alarm fixed sniffing rej
2. ect point 1 0E 06 sniffer probe clogged reject 1 0E 06 bargraph zoom on He reject point no depollution function off depollution reject point 1 0E 06 memo function active no memo display timer no memo timer value min s 00 10 cycle end function operator roughing overlap timer on roughing timer value min s 00 10 test timer value min s 00 10 start timer value min s 00 00 background suppression activation operator trigger reject point GL setpoint mbar 6 0E 00 Bypass setpoint mbar 5 0E 01 HS setpoint mbar 2 0E 02 SPECTRO MENUS automatic calibration off activation operator every 0050 cycles every 0010 hours filament in use 1 electronic zero 110 acceleration voltage V 221 electronic current mA O40 sensitivity coefficient 01 00 He calibrated leak location internal value 1 0E 07 unit mbar 1 sec year 2001 loss per year 2 00 temperature C 20 temp coefficient C 3 00 MAINTENANCE MENUS primary mnt periodicity hours 10000 primary mnt due in hours 10000 high vac mnt periodicity hours 08000 high vac mnt due in hours 8000 roughing mnt periodicity hours 08000 roughing mnt due in hours 8000 filament 1 running time hours 0 filament 2 running time hours 0 customed mnt period cycles 5 0E 03 customed mnt due in cycles 5 0E 03 OTHER MENUS test mode selection high sens inlet vent off hard vacuum correction off hard vacuum cor coefficient 1 00E 00 sniff
3. ing correction off sniffing cor coefficient 1 00E 00 unit mbar 1 sec display language english user interface f 4 password value 5555 TYPICAL VACUUM VALUES Pu_gf 1 00000 Mu_gf 00099 9 Pu_n 1 00000 Mu_n 00001 0 Mu_r1d 00040 0 DATE AND TIME VALUES last stop Jan 01 1 00 00 00 last start Jan 01 2001 00 00 03 last calib ok Jan 01 1 00 00 00 detector counter h m s 00000 01 27 2 2 Alcatel Vacuum Technology France ASM 182 TD ASM 192 T2D User s Manual GB 00981 Edition 04 December 01
Download Pdf Manuals
Related Search
Related Contents
USER'S MANUAL 雨量記録監視装置RF-3 アメンボの製品カタログ StaRRsed Flex User Manual Copyright © All rights reserved.
Failed to retrieve file