Home
SmartMan Code User Manual – 4.0 Running The Code Table of
Contents
1. Megacode Manual 4 0 How To Run the Code Software v1 4 3 Oct 2013 Page 4 In the on screen report and in the printed report produced once the activity has ended it will indicate when the IV line was established Intubate You can intubate the victim during any cycle after the first Button AED analysis You do not have to intubate You can continue CPR for every cycle without placing an advanced airway Once you have an advanced airway CPR changes to 10 1 ALS When the intubation is successful click on the Intubate Button or press the letter t on the keyboard In the on screen report and in the printed report produced once the activity has ended it will indicate when intubation has been done STOP Stop the megacode activity any time by clicking the STOP Button Button If you do not click on STOP you will not receive a report and you will not be able to print the report at a later time Maximum time for the activity is 20 minutes If the program reaches this time limit the program will end and the results will be saved Defib Use of the AED is NOT a button It is activated by pressing Space Bar the SPACE BAR It can be activated at anytime When the SPACE BAR is pressed a popup will indicate that the AED is analyzing Although this popup will remain on the screen for 3 seconds you can continue to perform chest compressions during if you wish lt is up to your trainer to determine whether it is a shockable rhythm in which
2. case you should wait for the AED to charge or whether it is a non shockable rhythm You determine when you re start chest compressions SmartMan Megacode Manual 4 0 How To Run the Code Software v1 4 3 Oct 2013 Page5 4 3 9 Current Progress Area During Code This area displays information on the number of compressions performed number of CPR cycles which cycle you are in and which stage you are in As you move to the next cycle and the next stage information is updated SmartMan Megacode Manual 4 0 How To Run the Code Software v1 4 3 Oct 2013 Page 6
3. the description of what is expected in the activity As you perform this area will give you a status of which stages have been completed After Stage 1 this information is displayed once you press the SPACE BAR to have the AED analyze 4 3 2 Real Time Feedback Area During Code This is the bottom graph area and is active as you perform CPR It provides an at a glance view of the quality of the chest compressions and the ventilations The best performance for the patient is bright green If every bar is not bright green then some aspect of the particular skills needs to be adjusted The more bright greens produced the greater the chance that the performance will have a positive influence on survival outcome Top SmartMan Megacode Manual 4 0 How To Run the Code Software v1 4 3 Oct 2013 Page3 4 3 3 Health Status Area During Code This area shows the relationship between chest compressions performed the quality of those chest compressions and the time from onset It provides an at a glance view of the current health of the patient Think of this as representing blood flow to the brain 4 3 4 Influencing the Health Score You influence the health score by performing better compressions without interruptions For either of these the health score will drop It will drop to 20 in 50 seconds If the Health Status is20 or aboveyou can maintain the status but not improve it If Health Status is below 20 you will see it rise w
4. SmartMan Code User Manual 4 0 Running The Code For SmartMan Code Megacode and Megacode ROC V1 1 0 current at 1 October 2013 Table of Contents SmartMan Code User Manual 4 0 Running The Code ccccccccseeeeceeceeeeeeeseeeeeeeeseeeeesanees 1 SMARTMAN CODE SMARTMAN MEGACODE SMARTMAN MEGACODE ROC 1 4 0 HOW TO RUN THE CODE SOFTWARE ssscsssesssesssesssesssessecssecstesssecssessecasecatecateesseeseeesees 2 AT SEE GE THE ACTIVITY oaa E E A E A EAS 2 A KNOW BEFORE YOUR RUN THE CODE sicsssseisciassiosataaceucannndudanacensnaaaimvadiccunmasiitiaadusaateewancesbuenierauauevtaniatsdaadteaneiesmuetae 2 ae EE UG 1G e E E A A A A AE A E E tieatemtiee seater 2 A 22 HOW tO Start The CORE aciendo e A AE AE AS R 2 4 2 3 How to Stop The Code and Save Results scssrsssiirsisirerroirrissseisrisssenriidretsr kantes ki anisi srianan inais seakari stna 2 4 2 4 If Code Stops By Itself No Results are Saved ccccssssecccccesseccecaesseccecseeseceeseueecceessaaeceesueaecessugeeeessegaeeeeees 2 4 2 5 Indicate a Critical EVENT sscninstceawintiedivccndiancnnbcaecs svandtinussesae ceswanieatnalbeaeonstuedncinteeanabesiradeaibapurwneuedendeadateamcesanndeatasladt 2 4 2 6 Print and After Action Report AAR ccccccccsssecccccesseccccceesecceseueeeccseeeeeecseseueseeeeseueecesseeeeecessaueeeeessengeeeets 3 A THE COU SCRE E Nsoo N A E E A S E E E 3 4 3 1 Information Area During Code sasisininaswitiaciencesanniaessnandawnv
5. annndnawadndanavevanacionsiadenamasestauedadicersaveendancabdawaunaandaniailnes 3 4 3 2 Real Time Feedback Area During COde cccccccccsssecccccessecccceeeeeccceeeeeecceseuseecessaueeecesseenecessueeeecesseggeeeeees 3 4 3 3 Health Status Area D ring Code xc scocscsissdeeusssceevossialatuadsansanadasbeaues akeatoatsabdamedeaabaaedebbesuecaneedwadsabdsacianabenddaabaee 4 AoA Te Ge Me Heath SCOE cance caster ce eseenc stieca an n ER TETEE EO 4 ASD Vee LEVE surrer irna nn ES ER 4 A36 T reet evel for eal N STATUS orsina anenai DANE EEA EE E OE A 4 Aa er VOU COE oopen O A E E 4 4 3 8 Intervention Buttons During Code sseeessssssssrrrsessrrrssssrrressrrtresssreresssteressrtreessrtrressttresseteresertereseeeeeeseeereeses 4 4 3 9 Current Progress Area During Code ccccccscssssssecccceeceeeseecccceeeauseseeeeceeseausssecceeeesaaeaseeeeeeeeeuaanseeeeeeeeagaees 6 SMARTMAN CODE SOMARTMAN MEGACODE SMARTMAN MEGACODE ROC This is a training activity to help you improve how several people perform in their response to a Sudden Cardiac Arrest event This normally is run with a group of between 3 and 6 people and one person is usually nominated as Team Leader or Head Nurse or Code Nurse etc SmartMan Megacode is designed to give maximum flexibility to how the code is run You coordinate the roles and SmartMan will provide an accurate time line of critical events It also will provide an unsurpassed accurate detail related to how the CPR skil
6. ith better compressions with no interruptions i 4 3 5 Maintenance Level This shows as a line on the Health Status Area As time progresses the maximum value you can maintain via perfect chest compressions is indicated by the horizontal yellow line 4 3 6 Target Level for Health Status If the code has run longer than 5 minutes a health score of 20 is excellent With high quality CPR you can keep the flow of blood of an SCA patient at 20 of a normal f 4 3 7 Timer During Code This starts as soon as the code is called It is cumulative in minutes and seconds and lets you know how long the code has been running The various buttons will report when on the timeline the various interventions were performed when you clicked on the corresponding button 4 3 8 Intervention Buttons During Code You can click on these buttons anytime during the code The time these were administered will be shown in the results Top Button Description Administer drugs at any time Epinephrine Click Button or press E Key Vassopresin Click Button or press V Key Amiodarone Click Button or press A Key Drugs Buttons There is no maximum number of times you can press these buttons In the on screen report and in the printed report produced once the activity has ended it will indicate which drug was given and when IV Click on this Button or press the letter on the keyboard Button to indicate that an IV line has been established SmartMan
7. ls were performed SmartMan Code Training is also the only product in the world that is providing best practice training for AHA and ROC Protocols SmartMan Megacode Manual 4 0 How To Run the Code Software v1 4 3 Oct 2013 Pagel 4 0 HOW TO RUN THE CODE SOFTWARE 4 1 SELECT THE ACTIVITY AHA or ROC You have one or two options on this page depending on which version you have purchased NOTE In order to have an accurate display for the ROC protocol you must have purchased a ROC protocol Airway SmartMan ALS manikin otherwise physical changes must be made if you only have the standard Airway SmartMan manikin 4 2 KNOW BEFORE YOUR RUN THE CODE In order to run the code there are a few things you need to know l 4 2 1 Length of Code The code can run for a maximum of 20 minutes f 4 2 2 How to Start The Code Start the program when the code is called You will see the timer is running middle The program must have something happen such as a compression performed within the first 40 seconds or it will terminate f 4 2 3 How to Stop The Code and Save Results Stop the code at any time by clicking on the redish STOP Button at the middle of the screen You will only see the STOP Button when the code is running When you press the Stop Button the program will stop This will save the results and the program will create and display results This means that you can now view what was done and you can create an After Action Report AAR by pressi
8. ng the Print Button middle of page 4 2 4 lf Code Stops By Itself No Results are Saved When the program will stop time out e f you do not do anything within 40 seconds it will stop No results will be saved e lf you do not press the Defib Button to Analyze within 10 minutes it will stop No results will be saved l 4 2 5 Indicate a Critical Event When a critical event such as establishing an IV or having the AED Analyze takes place you must press the corresponding button on the screen You can click on the button or press the related keyboard key Perform your protocol click on the button middle of the screen or press the key Top SmartMan Megacode Manual 4 0 How To Run the Code Software v1 4 3 Oct 2013 Page2 4 2 6 Print and After Action Report AAR When you have completed a code and the results are showing on the screen press the Print Results Button near the middle of the screen 4 3 THE CODE SCREEN Once you start the Megacode there are 5 separate areas which display information on what is being performed You will see the following screen Quit 2010 Guidelines for CPR and ECC Menu Help Information negra tra oia Health Status Area a gt F Timer Information Area intervention Vv N a ct Suaegawsan gt ew wessions f wr Comp Real Time Feedback Area Ventilations Top f 4 3 1 Information Area During Code Before you begin this area provides
Download Pdf Manuals
Related Search
Related Contents
handylab multi 12 Insuflation Test Set — 37731-01D Sennheiser HD 437 Cooper Lighting ED28 User's Manual Android対応Bluetooth体重計 取扱説明書 Copyright © All rights reserved.
Failed to retrieve file