Home

US E R M ANUAL

image

Contents

1. Win AE Control Software Main window Curr temp Set temp T novaetech 8 T emm 15 Seconds Freeze Current freg Hz Lg Lo Save data Activate temp control 2 N L Not connected not storing data no temp control Top Menu Bottom Menu Side Bar Menu Data Plot Screen SLNE AE QCM 2 0 User Manual v 1 0 Win AE Control Software i Functions novaetech 8 Top Menu File Sub Menus Connect device gt Execute the connection with the AE QCM Device settings gt Popup window PID Parameters gt Sets the Proportional Integrative Derivative values for the Peltier control Get current gt Gets the current PID values Set as default gt Sets new PID values as default Storage Average points Set gt Sets the number of points stored per second Close gt Closes without modification Firmware update gt Allows firmware updates provided by Novaetech Set temperature gt Popup window Control mode Parameters gt Sets the type of control of the Peltier temperature Set point Set point temperature gt Fixes the final temperature to be reached Linear ramp Ramp pendence gt Not active in this version Storage folder gt Sets the folder where to store data default Documents AEContro l Exit gt Exit the program AE QCM 2 0 User Manual v 1 0 e Win AE Control Software g novaetech 8 Bottom Menu gt Connection icon gt Execute the c
2. 7 Be novaetech novaetech 8 AE QCM 2 0 tel 39 081 0788140 fax 39 081 0111803 www novaetech com email info novaetech it AE QCM 2 0 User Manual v 1 0 i o novaetech 8 Certification Novaetech certifies that this product met its published specifications at the time of shipment Warranty This Novaetech product is warranted against defects in materials and workmanship for a period of one 1 year from the date of shipment Service For warranty service or repair this product must be returned to a Novaetech authorized service facility Contact Novaetech or an authorized representative before returning this product for repair Information in this document is subject to change without notice Copyright Novaetech S r l 2010 All rights reserved Novaetech S r l Via Coroglio 57d 80124 Napoli Italy www novaetech com Printed in Italy AE QCM 2 0 User Manual v 1 0 i o novaetech 8 Contents Safety and Preparation for Use Getting Started AE CONTROL Unit Side Panels Overview AE QCM Sampling Head Overview Unpacking Quick Start Instructions AE QCM 2 0 User Interface Win AE Control Software 10 Crystal Installation 15 QCM Measurements 17 Specifications AE QCM 2 0 19 OO J OO 0 bo AE QCM 2 0 User Manual v 1 0 i o novaetech 8 Safety and Preparation for Use Line Voltage The AE QCM 2 0 Control Unit operates at 9VDC Power consumption is max 18W total Power AC DC Adapter
3. The AE QCM 2 0 requires power AC DC adapter 9V max 1 5A for connection to the power source Keep power line and all the other electrical wiring in your experimental setup neatly organized and in good working condition Inspect all wires periodically for problems as part of your safety checkups AE QCM 2 0 User Manual v 1 0 e Safety and Preparation for Use B novaetech amp Operate Only With Covers In Place To avoid personal injury do not remove the product covers or panels Do not operate the product without all covers and panels in place Liquid Contact This product is intended for use only in a clean dry laboratory environment Operation in other environments may cause damage to the product and reduce the effectiveness of the safety features To reduce the risk of fire or electrocution do not expose this product to rain or excessive moisture Be careful not to spill liquid of any kind onto or into the product Serviceable Parts The AE QCM 2 0 does not include any user serviceable parts inside WARNING Peltier Operations During measurement operations with the Peltier activated it is important to connect the sampling head to a suitable heat sink through holes on the bottom side of the sampling head can be used to correctly fix it to the heat sink AE QCM 2 0 User Manual v 1 0 T novaetech 8 Getting Started This section provides instructions for unpacking checking and connecting the AE QCM 2 0 Quartz Cry
4. 0 T novaetech 8 Crystal Installation This section describes the procedure to install or replace the QCM crystal in the Sampling Head AE QCM 2 0 Quartz Crystals sensor are carefully selected by Novaetech in order to have the best coupling with the reference crystal mounted inside the sampling head For this reason please communicate the AE QCM sampling head code reported on the heat sink in the bottom side when you order new fresh quartz crystals AE QCM 2 0 quartz crystals are mounted in Al holders for the easy installation and replacing in the sampling head see Figure Electrode up side AE QCM 2 0 User Manual v 1 0 Crystal Installation y novaetech 8 Mounting and de mounting of crystals should be always done with the maximum care in order to keep the crystals safe and to assure the correct electrical contact The quartz sensor is correctly installed when gold electrode fits perfectly the circular window on the up side if the sampling head In order to avoid frequency noise do not touch sensor holder during the measurement operations In any case do not force the insertion of quartz crystal in the sampling head It is suggested not to replace a sensor crystal until the saturation is reached AE QCM 2 0 User Manual v 1 0 7 novaetech 8 QCM Measurements The first use of QCMs was as mass sensors and thickness monitors in gas phase thin film depositions To this date this continues to be an important area
5. d by dividing the mass per unit area M provided by Sauerbrey s equation by the material s density p AE QCM 2 0 User 18 Manual v 1 0 Specifications AE QCM 2 0 Electrical Power supply 9VDC Power consumption max 230mA max 2A with operating Peltier element Physical Dimensions mm 200 x 72 x 184 WHD Weight g 948 Operating temperature 0 C 40 C Material Ale ABS i o novaetech 8 Quartz Crystals polished Frequency 10 MHz AT cut plano plano Blank Diameter 0 34 inch Electrodes titanium gold diameter 0 201 inch Sensitivity 2 26x1048 Hz g cm 2 Crystal Holder Material Al Sampling head Material PTFE AE QCM 2 0 User Manual v 1 0 AE QCM 2 0 User Manual v 1 0 i o novaetech 8
6. ed PIN useful for the choice of the wires r S E zeen CECR SSES DREES ooo pe o Yaw T e foem fa vo fe ooo oo fee o Je i AE QCM 2 0 User Manual v 1 0 AE QCM 2 0 User Interface i 8 novaetech 8 Win AE Control Software Note Once you have received the AE QCM 2 0 system box please immediately contact Novaetech in order to receive AE Software It will be sent by email AE Software is a control and data acquisition software By means of AE Software it is possible to visualize and record data coming from the AE QCM Sampling Head Frequency and Sensor Temperature It is also possible to control the crystal sensor temperature by driving the built in QCM sampling head Peltier element Win AE Control Software requires Windows Installation gt Start the installation program file SetupWinAEControl msi Now you can find the AE Control software icon on the desktop The installation program also creates the folder Novaetech srl under Windows folder Program Files gt Start the installation of the AE Control Unit drivers Connect Control Unit to the PC by the USB cable Power On the Control Unit and check the front panel display for connection Follow the Windows standard driver installation procedure by searching for the drivers in the Novaetech sr WinAEcontrol Drivers folder Once the installation of drivers is concluded Win AE Control software is ready for use AE QCM 2 0 User 10 Manual v 1 0
7. ftware See User Interface Section for AE Control software installation gt Turn the power switch ON and check on the front panel display that AE QCM is connected and is measuring Frequency and Temperature gt Start Win AE Control software and click on the connection icon gt The AE QCM 2 0 System is now ready for measurements Frequency and Temperature are displayed on the front panel display and on the host PC monitor gt Before starting Peltier operations please read the Safety and preparation for use Section AE QCM 2 0 User Manual v 1 0 T novaetech 8 AE QCM 2 0 User Interface The AE QCM 2 0 system user interface concerns the Front Panel Display e Cable connection e Win AE Control Software Front Panel Display A 128 x 64 Dots LCD Graphic Display on the front panel of the AE CONTROL unit simply displays AE QCM 2 0 Connection status Measured Frequency and Temperature Peltier status cooling warming and software version AE QCM 2 0 User Manual v 1 0 AE QCM 2 0 User Interface i 8 novaetech 8 Cable connection The AE QCM Sampling Head can be connected to the Control Unit by means of a cable with a Micro D 9 PIN connector for the connection with Sampling Head and a D SUB 9 PIN connector for the connection with the Control Unit In order to prepare an AE QCM 2 0 connection cable for your own experiment the PIN COLOR Table is reported Please pay attention to the current expected on the indicat
8. of application for this technology Sauerbrey Equation Sauerbrey s equation is often used to calculate mass loadings and thin film thicknesses in vacuum depositions The basic assumption is that the incremental change in mass from the foreign film is treated as though it were really an extension of the thickness of the underlying quartz The foreign film is considered rigid and so thin that it does not experience any shear forces during vibration As a result the sensitivity factor S is a fundamental property of the quartz crystal and does not consider any of the properties of the foreign film i e it is only dependent on the acousto elastic properties of quartz By means of Sauerbray Equation mass per unit area M in function of resonance Frequency shift Av S is crystal sensitivity AE QCM 2 0 User Manual v 1 0 QCM Measurements i 8 novaetech 8 The dependence of the frequency change on the mass coverage per unit area emphasizes the fact that within certain limits the sensitivity factor is independent of the electrode geometry Thus in theory the QCM mass sensor does not require calibration for this application This ability to calculate mass loading from first principles is obviously a very attractive feature of these devices Film thickness Film thickness is often the parameter of interest in gas phase thin film depositions If the mass coverage is believed to be uniform the thickness t of the film is easily calculate
9. onnection with the AE QCM gt Save data check box gt Save the data in the set storage folder when checked gt Activate temp control check box gt Check the box to activate the temperature control with set parameters Side Bar Menu In this menu Current Frequency Current Temperature Temperature Set for control and Peltier operation Warming Cooling are displayed The following functions can be implemeted gt Clear gt Clear the data plot screen gt Freeze gt Freeze actual data plot screen gt Autoscale Hz gt Autoscale the frequency data plot gt Autoscale C gt Not active in this version AE QCM 2 0 User Manual v 1 0 e Win AE Control Software B novaetech amp Data Plot Screen In the plot screen Current Frequency Current Temperature Temperature Set for control are plotted in function of time Seconds In In this screen the Hz scale can be directly modified by inserting min max values in the box on the scale Note If the Hz and T plotted appear of some orders different from those showed on front panel display it is necessary to change decimal separator comma with the point in Windows Control Panel Storage Data Format The storage data file is automatically generated with the following name format yyyyMMdd_HHmmss_f txt The data are store in the following format yyyyMMdd_HHmmss f Hz C NOT NUMBER when Point Temp is not set AE QCM 2 0 User Manual v 1
10. rocedure Read and follow all installation and operation instructions in this manual to ensure that the performance of this instrument is not compromised gt Open the box es and inspect all components of the AE QCM 2 0 System gt Report any damage to Novaetech immediately gt Compare the contents of the shipping boxes against your original order and the checklist below Report any discrepancies to Novaetech immediately Checklist Standard Equipment Supplies x AE CONTROL Unit The QCM Controller VAE QCM Sampling Head The QCM with Peltier element and T sensor integrated v Power supply ac dc adapter 9V 1 A v USB2 0 Cable Connection Cable Micro D D SUB cable only for instrumentation test not good for experiment One 1 QCM crystal polished The Sensor Quartz Crystal with holder v User Manual Optional Equipment Replacement Quartz Crystals with holders eSpecific connection cables AE QCM 2 0 User Manual v 1 0 T novaetech 8 Quick Start Instructions gt With the power switch in the OFF position connect the AE CONTROL Unit to the power supply adapter provided gt Connect the AE CONTROL Unit to the AE QCM Sampling Head using the connection cable see User Interface Section gt Mount a fresh quartz crystal with holder in the AE QCM head See special instructions in the Crystal Installation section gt Connect the AE CONTROL USB port to your host PC where you have installed the Win AE Control so
11. stal Microbalance to its accessories and to your experiment Quick Start instructions are also provided to easily perform QCM measurements The AE QCM 2 0 System is a high precision mass measuring sensor featuring excellent performances in the recovery of the beat oscillation frequency coming from two coupled working quartz crystals The sensor has an integrated control electronic and it can be used standalone by interfacing to any frequency meter oscilloscope or any kind of acquisition frequency system Sampling Head is provided with a temperature sensor and a Peltier element for temperature control of the quartz sensor Resonance frequency and Temperature are measured and displayed directly on the front panel In addition the AE QCM 2 0 has USB2 0 interface and comes with Windows software providing real time display and storage of QCM and thermal data AE QCM 2 0 User Manual v 1 0 7 novaetech 8 AECONTROL Unit Side Panels Overview Left Side oa USB2 0 Right Side POWER QCM D SUB ER ON OFF CONNECTOR POWER AE QCM 2 0 User 4 Manual v 1 0 WW Ze novaetech 8 AE QCM Sampling Head Overview Le e Le E 4 Ig Hr i Heat sink through holes M2 i kl ary i d NA wi li a o b t Heat sink through holes M2 AE QCM 2 0 User Manual v 1 0 Unpacking novaetech Before Setting Up Read the entire Safety and Preparation for Use section of this manual before starting any setup p

Download Pdf Manuals

image

Related Search

Related Contents

  TARGET2 user Manual v1.3 changes  Supporting Document - Maryland Patient Safety Center  LevelOne 100TX to 100FX-SC POE Converter  Les fiches descriptives des ZNIEFF Mode d`emploi  The C++ Language Tutorial  陸 上 自 衛 隊 仕 様 書  1 - One For All  

Copyright © All rights reserved.
Failed to retrieve file