Home
        View - Onset
         Contents
1.    NOTE  Onset allows one technical support contact  for each software license     Onset Technical Support  Onset Computer Corporation  470 MacArthur Blvd   Bourne  MA 02532  Mailing  PO Box 3450  Pocasset  MA 02559 3450  1 800 LOGGERS  1 800 564 4377   Phone  508 759 9500  Fax  508 759 9100   email  loggerhelp onsetcomp com       1997 1999  Onset Computer Corporation    HOBO   Warranty  The HOBO   products are warranted to be free from  defects in material and workmanship for a period of  one year from the date of original purchase  During  the warranty period Onset will  at its option  either  repair or replace products that prove to be defective   This warranty is void if the Onset products have been  damaged by customer error or negligence or if there  has been an unauthorized modification     Direct all warranty claims to place of purchase     Returning Products to Onset   Before returning a failed unit  you must obtain a Re   turn Merchandise Authorization  RMA  number from  Onset  You must provide proof that you purchased the  Onset product s  directly from Onset  purchase order  number or Onset invoice number   Onset will issue an  RMA number that is valid for 30 days  You must ship  the product s   properly packaged to protect against  further damage  to Onset  at your expense  with the  RMA number marked clearly on the outside of the  package  Onset is not responsible for any   package that is returned without a valid RMA number  or for the loss of the package by an
2. Application Notes                    1  Using the magnet   You must orient the magnet to the case correctly for  the HOBO State data logger to detect it  When the a eo  HOBO State sees the magnet it will blink its green     te FA State  LED light  When it cannot see the magnet it will a onset  blink its red LED light  The recommended orienta     tion  Diagram A   along with some that will not work Diagram A   Diagram B  are shown in the drawings at the right                                         Diagram B    A simple application  door monitor   Mount the magnet on the door using its two sided foam tape  Use   Onset   s software to launch the logger  then mount the HOBO State data  logger on the door jam using the hook and loop strip  The magnet will need to  be less than 1 4 inch from the logger case when the door is closed  and over  3 4 inch away when the door is open  Make sure that the logger blinks green  when the door is closed  and red after it has been opened  The logger will  record the times when the door is either closed or opened  The hook and loop  tape allows you to conveniently remove and replace the logger for readout           A door in a house  with small children living in it  recorded over one  thousand state changes during a one wekk period in the summer                    2  Measuring contact closures   The HOBO State can be used to measure contact closures  Connect the contacts to the black and  white wires on the contact closure cable  The polarity o
3. agnetic reed switch located  in the middle of the hinge of the case  opposite  the connectors   and an external contact closure  input  The logger will indicate a closed state if  either a magnet is present  or the external  contact is closed     A different kind of logger   All previous HOBO loggers have recorded  measurements with their sensors at regular  preset intervals  These loggers record the time  evolution of a physical property  temperature   RH  etc    Usually the physical property has a  long time constant associated with it  water and  air temperatures usually change slowly   so  measuring at an interval that is shorter than  this time constant will give a realistic represen   tation of what has happened  The HOBO State  does not have a preset interval  It will always be  monitoring and will only record when a change  of state occurs     Inside this package   The HOBO State  Onset  H06 001 02   is shipped with       HOBO State data logger      Contact closure cable   Onset  CABLE 2 5 STEREO       Magnet   Onset  08 MAGNET FM       Mounting Accessories   Magnet  Hook and loop tape  Double sided tape      This User   s Manual   Onset  MAN H06 001 02     Mounting options   Included with your HOBO H6 data logger are three  options for mounting it on location  a magnet  hook  and loop tape  and double sided tape  These can be  stuck on the back of your HOBO  When using the  magnet  note that it works best on flat surfaces     HOBO State data loggers in detail  HOBO S
4. f this connection does not matter  The red  wire is not connected on the HOBO State data logger  Using the external contact closure input  allows the logger to be mounted remotely from the contact  Make sure that no external voltage is  applied to the contacts  When measuring contact closures  the contacts should not be connected to  anything dse even ground     3  Measuring the presence of positive DC voltages   Put a diode in series with the white wire on the external contact dosure cable  The diode will   block the positive input  Note  it is critical that you connect the diode with the polarity shown in  Diagram C  This will only work if the input voltage is ground when the positive voltage is not  applied  Never apply a negative voltage to this input  the diode will not block it  Make sure you use  a diode that has a breakdown voltage high enough to block the positive voltage you intend to apply   In no case should you use this technique to connect the logger to any AC voltage  or a DC voltage  above 15 volts     input  voltage    Diagram C    Detailed Specifications    Minimum state duration  1 2 second   Time Accuracy   100 ppm at 20  C  full dependence shown in Plot A   Capacity  2 000 state changes  requires 8K of memory in HOBO  Shuttle to fully offload    External contact input  relay switch or contact closure   Length of included external contact cable  6    Operating temperature   20  C to  70  C   4  F to  158  F     Relative humidity range 0 to 95   non condens
5. ing   Size weight  2 375  x 1 875  x 0 75  approximately 1 oz    Battery  CR 2032  lithium   provides one year of continuous use   Storage temperature   40  C to  75  C   40  F to  167  F      Connecting the communications cable   The HOBO State data logger requires Onset   s software and a PC interface cable  Connect the cable  into the 3 5 mm jack on the logger  See diagram D  and into a working serial port of your computer  If  the serial port was recently used for a network  modem  or printer  the port may still be configured as  such and the computer should be restarted first  When attaching the PC interface cable to your logger   make sure that the interface cable is inserted completely into the jack on the logger     Internal magnetic reed switch  external contact opening   The HOBO State data logger records contact closures openings of its internal magnetic reed switch  a  glass reed switch located inside the box on the edge opposite the connectors  see Diagram E  and  contact closures  open shorted  in a cable connected to its 2 5 mm jack  Diagram D   The HOBO State  data logger detects the cable s open shorted condition by applying a positive voltage pulse to the tip   white wirein cable   The black wire is ground and the red wire is not connected  Pairs of state changes  that occur in less than half a second may not be recorded  In applications where state changes always  appear in closely spaced pairs  a HOBO   Event data logger should be used     Operation indica
6. splay this data in graphical or tabular format  while earlier  versions display data in tabular format only as shown at right     Diagram D Diagram E             09 20 03 5 PM  11 27 96 09 20 11 0 PM__OPCN                            Service and Support  HOBO    products are easy to use and reliable  In  the unlikely event that you havea problem with  the hardware or software  please read the follow   ing   Who do I contact   Contact the company that you bought the loggers  from  Onset Computer Corporation or an Onset  Authorized Dealer     Before calling  you can evaluate and often solve  your problem if you try the following     1  Read this manual and the ReadMe file on the  disk  It may only take a few moments to get the  answers you need     2  Write down the events that led to the problem   Have you changed anything in your computer  recently  Are you doing anything differently     When contacting Onset Computer   Corporation  please indicate that you need Techni   cal Support for HOBO   products    Be prepared to     1  Provide the product number which is found on  the bottom of the logger  the software version and  serial number if present on the diskette     2  Provide details on the hardware and software  configuration of your computer including  manufac   turer  model number  peripherals  and version of  operating system     3  Completely describe the problem or question   The more information you provide  the faster and  more accurately we will be able to respond  
7. tate data loggers work well when there  are only two values to measure  i e  open or  closed  on or off   The HOBO State data logger  records the time at which a state change occurs   with a resolution of half a second   and records  nothing between these changes  If you wanted to  do this with a logger that uses preset intervals   you would have to set it to 1 2 second intervals   and an 8K logger would run out of memory in  about an hour  The HOBO State data logger  checks for the contact closure every half of a  second  and can record 2000 state changes  I ts  time out in the field is limited by the battery   about one year      No data is information  too   The HOBO State logger records the initial state  and a final state at readout  even if the state has  not changed  This allows you to determine the  entire period during which the HOBO State was  watching for state changes        
8. tion   The HOBO State data logger has twoLED lights  red and green  Diagram D   One of these LEDs will  blink every two seconds  if the contact is open the red LED will blink  if the contact is closed the green  LED will blink  Although the LE Ds blink every other second  the state is checked every half second   with state changes recorded as detected  If the battery voltage is low  both LEDs will blink every other    second regardless of the state   3  at  i jack Magnetic  Reed switch  location    Changing the battery  Diagram F       Plat 4     Timebase dependence             an an  oood             time base error  ppm                    0 20 40 60 80  erature    C        To change the battery  open the case as shown in Diagram E  Lift the  circuit board and remove the battery by carefully pushing it out with  a cotton swab with the tip removed or other small  blunt instrument   Be sure to install the battery with the printed side away from the  HOBO   s circuit board  Diagram F   The logger   s LEDs will blink  several times after the battery has been installed     Keep it dry   Your HOBO State data logger can be permanently damaged by  corrosion if it gets wet  Protect it from rain or condensation  Should  it get wet  remove the battery immediately and dry the board  completely with a hair dryer before reinstalling the battery     Data Format   The HOBO State records the exact moment of each change of  state  Current versions of BoxCar   and BoxCar   Pro allow you to  di
9. y shipping company   Loggers must be clean and free of any toxins before  they are sent back to Onset or they may be returned to  you     Repair Policy   Products that are returned after the warranty period  or that are damaged by the customer as specified in  the warranty provisions can be returned to Onset with  a valid RMA number for evaluation     Please contact Onset for more information and   prices on    ASAP Repair Policy   Onset will expedite the repair of a returned product   Data back    Service   HOBO    data loggers store data in nonvolatile  EEPROM memory  Onset will  if possible  recover  your data toa disk    Tune Up    Service   Onset will examine and retest any HOBO   data logger     Onset    BoxCar  and HOBO   are registered trademarks of Onset Computer Corporation   The CE mark identifies this product as complying with all relevant directives in the    European Union  EU      1323 F MAN H06 001 02    HOBO   State  User   s Manual    onset    computer corporation    ees int             The HOBO State data logger requires   Onset Computer Corporation   s logger software  for Windows and PC interface cable for opera   tion  Recommended software  BoxCar   3 0 or  any version of BoxCar   Pro  The HOBO State is  compatible with the HOBO Shuttle allowing for  convenient data retrieval     Introduction   Thank you for buying the HOBO   State data  logger  With proper care it will give you years of  reliable readings  The HOBO State data logger  has two inputs  a m
    