Home

E SPOT III User Manual ver 1

image

Contents

1. MAIN MENU SUB MENU OPTIONS VALUES Default Settings in BOLD DESCRIPTION Reset All Reset All Motors Reset Pan amp iilt Reset Pan Tilt Reset Function Reset Colors Reset Color Wheel Reset Gobos Reset Gobos Reset Others Reset Other Motors Test Channel Test function Effect Adjust Manual Control PAN Fine Adjustments Calibration Calibration Password Password 050 Standard Mode Basic Mode Select DMX Channel Modes Extended Mode User Mode A User Mode Set User Mode B User Defined Channel Assignment User Mode C Edit User Mode A Max Channel XX Edit User Mode Edit User Mode B realises Edit User Mode C PAN CHO1 Select Program Auto Pro Part Program 1 10 Program 1 Auto Pro Part2 Program 1 10 Program 2 Auto Pro Part3 Program 1 10 Program 3 Select Programs To Be Run Edit Program Program 1 Program Test Testing Program Edit Program Step 01 SCxxx Program In Loop Program 10 Step 64 SCxxx Save and Exit Pan Tilt Save and Automatically Return scene 00 Fade Time Edit Scenes Manual Scenes Edit Scene Time Scene 083 Input By Outside Stores Scenes via Ext DMX Console Rec Controller XX XX Automatic Scenes Recorder 15 E SPOT User Manual Ver 1 www elationlighting com PERSONALITY Status Settings Address Via DMX When ON define the desired DMX address via an extern
2. NO Function 0 19 Color amp Gobo Change Normal 20 29 Color Change to Any Position 30 39 Color amp Gobo Change to Any Position 40 59 NO Function 60 79 NO Function 80 84 ALL Motor Reset 85 87 PAN amp TILT Motors Reset 88 90 COLORS Motor Reset 91 93 GOBOS Motor Reset 94 96 NO Function 97 99 OTHER Motors Reset 100 119 nternal Program 1 Scene 1 8 120 139 Internal Program 2 Scene 9 16 140 159 nternal Program 3 Scene 17 24 160 179 Internal Program 4 Scene 25 32 180 199 nternal Program 5 Scene 33 40 200 219 Internal Program 6 Scene 41 48 220 239 nternal Program 7 Scene 49 56 240 255 NO Function 23 E SPOT User Manual Ver 1 www elationlighting com ERROR CODES When power is applied the unit will automatically enter a Reset Test mode This mode brings all the internal motors to a home position If there is an internal problem with one or more of the motors an error code will flash in the display in the form of XXer were as XX will represent a function number For example when the display shows OEr it means there is some type of error with the Pan motor If there are multiple errors during the start up process they will all flash in the display For example if the fixtures has errors on Channel 1 2 and 5 all at the same time you will see the error
3. 1 20 DMX Channels Specifications are subject to change without any prior written notice Rotation direction Clockwise or Counterclockwise of COLOR GOBO and PRISM effects depends on orientation of the fixture head MODE CHANNEL VALUE FUNCTION BASIC STAND EXTEND 0 255 PAN Movement 630 540 JE 0 255 Fine Control of PAN Movement 0 255 TILT Movement 270 4 0 255 Fine Control of TILT Movement COLOR 0 14 OPEN WHITE 15 29 RED 30 44 BLUE 45 59 GREEN 60 74 YELLOW 3 5 5 75 89 MAGENTA 90 104 ORANGE 105 119 LIGHT BLUE 120 127 PINK 128 189 Clockwise Color Wheel Rotation from FAST to SLOW 190 193 NO Rotation 194 255 Counterclockwise Color Wheel Rotation from SLOW to FAST 6 IND 0 255 FINE Adjustment of Color Wheel to Any Position 0 9 OPEN 10 19 Rotating Gobo 1 20 29 Rotating Gobo 2 30 39 Rotating Gobo 3 40 49 Rotating Gobo 4 50 59 Rotating Gobo 5 60 69 Rotating Gobo 6 70 79 Rotating Gobo 7 4 6 7 80 89 Gobo 1 Shake SLOW to FAST 90 99 Gobo 2 Shake SLOW to FAST 100 109 Gobo 3 Shake SLOW to FAST 110 119 Gobo 4 Shake SLOW to FAST 120 129 Gobo 5 Shake SLOW to FAST 130 139 Gobo 6 Shake SLOW to FAST 140 149 Gobo 7 Shake SLOW to FAST 150 199 Clockwise Gobo Wheel Rotation from FAST to SLOW 200 205 NO Rotation 206 255 Counterclockwise Gobo Wheel Rotation from SLOW to FAST 21 E SPO
4. AL SPECIFICATIONS SOURCE 90W Solid State Cool White LED Engine 20 000 Hour Average LED Life LED Life may vary depending on several factors including but not limited to Environmental Conditions Power Voltage Usage Patterns On Off Cycling Control and Dimming EFFECTS 3 Facet and Infinity Rotating Prism and Prism Macros Frost Filter Hybrid Wash Effect Motorized Iris and Focus High Speed Mechanical Shutter and Strobe Variable Dimming Curves COLOR 8 Dichroic Colors GOBOS 7 Interchangeable Rotating Indexing 65 CONTROL CONNECTIONS 3 DMX Channel Modes 14 16 20 RDM Remote Device Management 6 Button Touch Control Panel Full Color 180 Reversible LCD Menu Display 8 16 Bit Resolution Adjustable Movement 3pin 6 5pin DMX In Out PowerCON In SIZE WEIGHT Length 11 8 300mm Width 9 6 245mm Vertical Height 17 2 436 9mm Weight 23 0 Ibs 10 4 kg ELECTRICAL THERMAL AC 100 240V 50 60Hz 180W Max Power Consumption 13 F 113 F 25 C to 45 C APPROVALS RATINGS CE RoHs Compliant IP20 Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice 26 E SPOT User Manual Ver 1 ECATiow www elationlighting com elationlig g co COLORS AND GOBOS COLOR WHEEL BLUE GREEN YELLOW MAGENTA ORANGE LIGHTBLUE PINK bang Pos 2 Pos 3 Pos 4 Pos 5 Pos 6 Pos 7 Pos 8 INTERCH
5. ANGEABLE ROTATING GOBO WHEEL 1 OD 26 8mm r 7 Us ID 21 4mm ID 21 4mm ID 21 4mm ID 21 4mm_ ID 21 4mm ID K lt a ID 21 4mm Pos 1 Pos 2 Pos 3 Pos 4 Pos 5 Pos 6 Pos 7 425 eS IMPORTANT NOTICE REGARDING GOBO DIMENSIONS AND CUSTOM GOBOS OD Outside Diameter ID Image Diameter Due to varying manufacturing processes it is highly recommended to provide a gobo and holder sample from the fixture to 3rd party custom gobo vendors for accurate sizing PHOTOMETRIC DATA 2 5m 7 5m 19 BEAM Distance 250 8 2 ft Photometrics lux fe FULL ON Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice 27 E SPOT User Manual Ver 1 www elationlighting com DIMENSIONAL DRAWINGS 8 1 3 2 2 12 9 5 328 5mm 4 9 6 243 7mm A ag 436 9mm i in T en TTT Chen a 7m i 270 1mm 203 2mm Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice 28 E SPOT User Manual Ver 1 www elationlighting com OPTIONAL ACCESSORIES ORDER CODE ITEM TRIGGER CLAMP Heavy Duty Wrap Around Hook Style Clamp EWDMXSYSTEM Wireless DMX System 1 Transmitter 1 Receiver AC3PDMX5PRO 5 ft 1 5m 3pi
6. ETATION PROFESSIONAL ELATION EspPotii use E SPOT Iil User Manual www elationlighting com 2015 ELATION PROFESSIONAL all rights reserved Information specifications diagrams images and instructions herein are subject to change without notice ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged All non ELATION brands and product names are trademarks or registered trademarks of their respective companies ELATION PROFESSIONAL and all affiliated Companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and operation of this product Elation Professional USA 6122 5 Eastern Ave Los Angeles CA 90040 323 582 3322 323 832 9142 fax www elationlighting com info elationlighting com Elation Professional B V Junostraat 2 6468 EW Kerkrade The Netherl
7. Prism Indexing 7 9 11 128 189 Clockwise Linear Prism Rotation from FAST to SLOW 190 193 NO Rotation 194 255 Counterclockwise Linear Prism Rotation from SLOW to FAST i 0 255 Prism FINE Indexing 0 255 Continuous Adjustment from FAR to NEAR 0 31 Shutter CLOSED 32 63 NO Function Shutter OPEN 64 95 Strobe Effect SLOW to FAST 9 11 14 96 127 NO function Shutter OPEN 128 159 Pulse Effect In Sequences 160 191 NO Function Shutter OPEN 192 223 Random Strobe Effect SLOW to FAST 224 255 NO Function Shutter OPEN 22 E SPOT III User Manual Ver 1 ETATIOW www elationlighting m ELATIOS elatio g g co ELATION E SPOT III DMX Channel Values Functions Version 1 20 DMX Channels Specifications are subject to change without any prior written notice Rotation direction Clockwise or Counterclockwise of COLOR GOBO and PRISM effects depends on orientation of the fixture head MODE CHANNEL VALUE FUNCTION BASIC STAND EXTEND DIMMER INTENSITY 10 12 15 0 255 Intensity O to 100 16 DIMMER INTENSITY FINE 0 255 Dimmer Intensity FINE Adjustment 0 20 Standard 21 40 Stage 13 17 41 60 TV 61 80 Architectural 81 100 Theatre 101 255 Default to Unit Setting 0 191 MAX to MIN Diameter 192 223 Pulse Closing FAST to SLOW 224 255 Pulse Opening SLOW FAST 0 225 MAX to MIN Speed 13 15 19 226 235 Blackout with PAN and TILT Movement 236 245 Blackout with ALL Wheel Movement 246 255
8. R PACK A NEVER TOUCH FIXTURE DURING OPERATION AS IT MAY BE HOT NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK e For proper operation follow the Installation guidelines described in this manual Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts brackets included with this fixture should be used for installation Any modifications will void the original manufactures warranty and increase the risk of damage and or personal injury e Never look directly into the light source of this fixture to prevent risk of injury to your retina which may induce blindness Those suffering from EPILEPSY should avoid looking directly into the light source of this unit at all times The fan and air inlets must remain clean and never blocked Allow approx 6 15cm between this fixture and other devices or a wall for proper cooling e Always disconnect from main power source before performing any type of service and or cleaning procedure Only handle the power cord by the plug end never pull out the plug by tugging the wire portion of the cord e Do not operate this fixture if the power cord has become frayed crimped and or damaged If the power cord is damaged replace it immediately with a new one of similar power rating 7 E SPOT III User Manual Ver 1 www elationlighting com GENERAL GUIDELINES NEVER OPEN THIS FIXT
9. T User Manual Ver 1 PROFESSIONAL www elationlighting com ELATION E SPOT III DMX Channel Values Functions Version 1 20 DMX Channels Specifications are subject to change without any prior written notice Rotation direction Clockwise or Counterclockwise of and PRISM effects depends on orientation of the fixture MODE CHANNEL VALUE FUNCTION BASIC STAND EXTEND ROTATING GOBOS INDEX ROTATION GOBO WHEEL 1 0 127 Gobo Indexing 5 7 8 128 189 Clockwise Gobo Rotation from FAST TO SLOW 190 193 NO Rotation 194 255 Counterclockwise Gobo Rotation from SLOW to FAST 0 255 Gobo Rotation FINE Indexing 6 NAO DE A OTA P AORO 0 31 OPEN 32 63 3 FACET Prism 64 95 LINEAR Prism 96 127 FROST 128 135 Prism Gobo Macro 1 136 143 Prism Gobo Macro 2 144 151 Prism Gobo Macro 3 152 159 Prism Gobo Macro 4 160 167 Prism Gobo Macro 5 6 8 10 168 175 Prism Gobo Macro 6 176 183 Prism Gobo Macro 7 184 191 Prism Gobo Macro 8 192 199 Prism Gobo Macro 9 200 207 Prism Gobo Macro 0 208 215 Prism Gobo Macro 11 216 223 Prism Gobo Macro 2 224 231 Prism Gobo Macro 3 232 239 Prism Gobo Macro 4 240 247 Prism Gobo Macro 5 248 255 Prism Gobo Macro 6 TRAPEZOID amp 3 FACET ROTATING PRISM INDEX ROTATION 0 127
10. UP DOWN RIGHT and LEFT buttons Once you reach a field that requires adjusting press the ENTER button to activate that field and use the UP and DOWN buttons to adjust the field Pressing the ENTER button once more will confirm your setting You may exit the main menu at any time without making any adjustments by pressing the MODE ESC button NOTE To access the LCD Menu Control Display via the internal battery press and hold the MODE ESC button for 3 seconds The LCD Menu Control Display will shut OFF automatically about 1 minute from the last button press SPOT ill CEQTYV 9 13 E SPOT User Manual Ver 1 ETATIOW www elationlighting com ELATION E SPOT IIl SYSTEM MENU Specifications and features are subject to change without any prior written notice MAIN MENU SUB MENU OPTIONS VALUES Default Settings in BOLD DESCRIPTION Set Dmx Address A001 AXXX DMX Address Setting Dmx Value ALL DMX Value Display Slave Mode Slave Slave2 Slave3 Slave Setting Auto Program Master Alone Auto Program Current Time XXXX Hours Fixture Run Time From Power ON Total Run Time XXXX Hours Fixture Total Run Time Time Information Last Run Time XXXX Hours Clear Fixture Last Run Time LastRun Password Password XXX Password 038 Clear Last Run ON OFF Reset Fixture Last Run Time Temper
11. URE WHILE IN USE During the initial operation of this fixture a light smoke or smell may emit from the interior of the fixture This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp and will decrease gradually over time This fixture is a professional lighting effect designed for INDOOR DRY LOCATIONS ONLY on stage in nightclubs theatres etc Please make sure there are NO FLAMMABLE MATERIALS close the fixture while operating to prevent any fire hazard The fixture must be installed in a location with adequate ventilation at least 1 5 feet 5m from adjacent surfaces Be sure no air ventilation slots are blocked DO NOT attempt installation and or operation without knowledge how to do so DO NOT permit operation by persons who are not qualified to operate this type of fixture Most damages are the result of operations by nonprofessionals Consistent operational breaks may ensure the fixture will function properly for many years to come DO NOT shake fixture avoid brute force when installing and or operating fixture Always install the fixture with an appropriate safety cable When installing the fixture in a suspended environment always use mounting hardware that is no less than M10 x 25 mm also be sure the hardware is insert in the pre arranged screw holes in the bracket of the fixture Use the original packaging and materials to tr
12. al controller 1 Connect the fixture to the external controller and power ON 2 Set the DMX value of Channel 1 on the controller to 7 3 Set the DMX value of Channel 2 on the controller to 7 or 8 When set to 7 the DMX address can be set between 1 and 255 When set to 8 the DMX address can be set between 256 and 511 4 Using Channel 3 on the controller set the desired DMX address of the fixture Example 1 the desired DMX address is 57 set Channel 1 to a value of 7 set Channel 2 to a value of 7 and then set Channel 3 to a value of 57 Example 2 the desired DMX address is 420 set Channel 1 to a value of 7 set Channel 2 to a value of 8 and then set Channel 3 to a value of 164 256 164 420 5 After setting Channel 3 to the desired DMX address value wait for approximately 20 seconds for the fixture to complete the address reset function PERSONALITY Service Setting RDM PID Select various submenus via RDM RDM stands for Remote Device Management which provides the ability to control the device remotely while connected a DMxX bus ANSI E1 20 2006 by ESTA specifies the RDM standard as an extension of the DMX512 protocol Manual settings like adjusting the DMX starting address are no longer needed This is especially useful when the device is installed in a remote area RDM ready and conventional DMX devices can be operated in one DMX line The RDM protocol sends it
13. ands 31 45 546 85 66 31 45 546 85 96 fax www elationlighting eu info elationlighting eu DOCUMENT VERSION IEN Please check www elationlighting com for the latest revision update of this manual Document Software DMX Date Channel Notes Version Version Modes gt 1U01 1 21 gt 2U01 1 21 10 22 15 gt 3U01 1 21 14 16 20 Initial release gt 4U01 1 21 gt 5U01 1 21 2 E SPOT III User Manual Ver 1 www elationlighting com CONTENTS General Information 4 Warranty 6 Safety Instructions 7 General Guidelines 8 Fixture Overview 9 Fixture Installation 10 Fixture Menu 13 DMX Channel Functions And Values 21 Error Codes 24 Cleaning and Maintenance 25 Technical Specifications 26 Optional Accessories 29 3 E SPOT III User Manual Ver 1 www elationlighting com GENERAL INFORMATION INTRODUCTION Congratulations you have just purchased one of the most innovative and reliable lighting fixtures on the market today This fixture has been designed to perform reliably for years when the guidelines in this booklet are followed Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit These instructions contain important information regarding safety during use and maintenance UNPACKING Every fixture has been thoroughly tested and has been shipped in perfect operating
14. ansport the fixture in for service DO NOT TOUCH the housing bare hand during its operation Turn OFF the power and allow approximately 15 minutes for the fixture to cool down before replacing or serving LED LIFE The average LED Life hours may vary depending on several factors including but not limited to Environmental Conditions Power Voltage Usage Patterns On Off Cycling Control and Dimming 8 E SPOT III User Manual Ver 1 FIXTURE OVERVIEW www elationlighting com 10 12 13 14 16 Lens LCD Control Display ENTER Button LEFT Button DOWN Button RIGHT Button MODE ESC Button UP Button Handles 3pin DMX OUT 3pin DMX IN 5pin DMX OUT DMX IN powerCON IN Power Switch Fuse E SPOT III User Manual Ver 1 www elationlighting com FIXTURE INSTALLATION FLAMMABLE MATERIAL WARNING Keep fixture at least 5 0 ft 1 5m away from any flammable materials decorations pyrotechnics etc ELECTRICAL CONNECTIONS A qualified electrician should be used for all electrical connections and or installations Sr CAUTIONS For added protection mount the fixture in areas outside walking paths seating areas or in areas were unauthorized personnel might reach the fixture Ambient operating temperature range for this fixture is 14 to 113 F 10 to 45 C Do not use the fixture under or above this temperature Before mounting the fixture to any surface make s
15. anty periods set forth above And no warranties whether expressed or implied including warranties of merchantability or fitness shall apply to this product after said periods have expired The consumer s and or dealer s sole remedy shall be such repair or replacement as is expressly provided above and under no circumstances shall Elation Professional be liable for any loss and or damage direct and or consequential arising out of the use of and or the inability to use this product G This warranty is the only written warranty applicable to Elation Professional products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published 6 E SPOT III User Manual Ver 1 ETATIOW www elationlighting m ELATIOS elatio g g co SAFETY INSTRUCTIONS This fixture is an extremely sophisticated piece of electronic equipment To guarantee a smooth operation it is important to follow the guidelines in this manual The manufacturer of this device will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual This device falls under PROTECTION CLASS 1 It s essential this device be grounded properly Only qualified personnel should perform all electrical connections INDOOR 5 U S E ONLY DO NOT EXPOSE FIXTURE RAIN AND MOISTURE UNPLUG POWER BEFORE SERVICING FIXTURE DO NOT PLUG FIXTURE INTO A DIMME
16. ature Info Head Temperature XXX C F Temperature in Fixture Head Information Fan Speed HeadFan1 XXX RPM Fan Speed Display U01 V1 2 1 2U01 V1 2 1 Software Version 3U01 gt V1 2 1 Software Versions 4U01 gt V1 2 1 5U01 V1 2 1 Error Info Error Record 1 Error Record 10 Error Info History Address via DMX ON OFF Set Address Via DMX No DMX Status Close Shutter Hold Auto Run if No DMX Auto Pan Reverse ON OFF Pan Reverse Movement Status Settings Tilt Reverse ON OFF Tilt Reverse Movement Pan Degree 630 540 Pan Degree Select Feedback ON OFF Movement Feedback Hibernation ae a Stand By Mode Password Password 050 Service Password Personality Service Setting RDM PID XXXXX RDM PID Code Clear Err Info ON OFF Clear Error Info History Fans Control Auto High Low Fans Speed Select Shutoff Time 02 60m 05m LCD Display Shut Off Time Display Setting Flip Display ON OFF Display Reverse 180 Key Lock ON OFF Key Lock Disp Flash ON OFF Display Flash when NO DMX Signal Temperature C F Celsius Fahrenheit Temperature Switch Between C F Initial Status Control XXX Initial Effect Position Dimmer Modes Standard Stage TV Architectural Theatre Set Dimmer Mode Reset Default ON OFF Password 011 Restore Factory Settings 14 E SPOT User Manual Ver 1 ELATION E SPOT IIl SYSTEM MENU www elationlighting com Specifications and features are subject to change without any prior written notice
17. ave unit receives data from the Master unit according the group which the Slave unit was assigned to If e g a Slave unit is set to Slave 1 in the menu Set to Slave the Master unit sends Auto Program Part 1 to the Slave unit If set to Slave 2 the Slave unit receives Auto Program Part 2 To start an Auto Program proceed as follows 1 Slave Setting e Select Function Mode e Press ENTER to confirm e Select Set to Slave e Press ENTER to confirm e Select Slave 1 Slave 2 or Slave 3 e Press ENTER to confirm e Press MODE ESC in order to return to the main menu 2 Automatic Program Run e Select Function Mode e Press ENTER to confirm e Select Auto Program e Press ENTER to confirm e Select Master or Alone e Press ENTER to confirm e Press MODE ESC in order to return to the main menu 18 E SPOT User Manual Ver 1 www elationlighting com EDIT PROGRAM Record Controller Working With Built In Programs continued 3 Program Selection for Auto Pro Part Select Edit Program e Press ENTER to confirm e Select Select Programs e Press ENTER to confirm e Select Auto Pro Part 1 Auto Pro Part 2 or Auto Pro Part 3 and select which Slave program is to be sent Selection Part 1 means that the Slave unit runs the same program as the master units e Press ENTER to con
18. condition Carefully check the shipping carton for damage that may have occurred during shipping If the carton appears to be damaged carefully inspect your unit for damage and be sure all accessories necessary to operate the unit have arrived intact In the event damage has been found or parts are missing please contact our customer support team for further instructions Please do not return this unit to your dealer without first contacting Customer support at the number listed below Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS e 1 Omega Bracket e 1 powerCON Cable Manual amp Warranty Card 4 E SPOT User Manual Ver 1 www elationlighting com CUSTOMER SUPPORT Elation Professionale provides a customer support line to provide set up help and to answer any question should you encounter problems during your set up or initial operation You may also visit us on the web at www elationlighting com for any comments or suggestions For service related issue please contact Elation Professional ELATION SERVICE USA Monday Friday 8 00am to 5 00pm PST Voice 323 582 3322 Fax 323 832 9142 E mail support elationlighting com ELATION SERVICE EUROPE Monday Friday 08 30 to 17 00 CET Voice 31 45 546 85 30 Fax 31 45 546 85 96 E mail support elationlighting eu WARRANTY REGISTRATION Please complete and mail in the enclosed warranty card or reg
19. essional factory unless prior written authorization was issued to purchaser by Elation Professional if the product is damaged because not properly maintained as set forth in the product instructions guidelines and or user manual D This is not a service contract and this warranty does not include any maintenance cleaning or periodic check up During the periods as specified above Elation Professional will replace defective parts at its expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Elation Professional under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of Elation Professional All products covered by this warranty were manufactured after January 1 1990 and bare identifying marks to that effect E Elation Professional reserves the right to make changes in design and or performance improvements upon its products without any obligation to include these changes in any products theretofore manufactured F No warranty whether expressed or implied is given or made with respect to any accessory supplied with the products described above Except to the extent prohibited by applicable law all implied warranties made by Elation Professiondal in connection with this product including warranties of merchantability or fitness are limited in duration to the warr
20. firm e Press MODE ESC in order to return to the main menu 4 Program Selection for Edit Program Select Edit Program e Press ENTER to confirm Select Edit Program e Press ENTER to confirm Select the desired program With this function you can edit specific scenes into a specific program e Press ENTER to confirm e Press MODE ESC in order to return to the main menu 5 Automatic Scene Recording Select Edit Program e Press ENTER to confirm Select Edit Scenes e Select desired scene numbers A maximum of 250 scenes can be programmed e Press ENTER to confirm e Press MODE ESC in order to return to the main menu 19 E SPOT User Manual Ver 1 www elationlighting com EDIT PROGRAM Record Controller Working With Built In Programs continued Example Program 2 includes scenes 10 11 12 amp 13 Program 4 includes scenes 8 9 amp 10 Program 6 includes scenes 12 13 14 amp 15 Auto Pro Part 1 is Program 2 Auto Pro Part 2 is Program 3 Auto Pro Part 3 is Program 6 The 3 Slave groups run the Auto Program in certain time segments as shown in the following picture Part 1 P soenan 2 scone ta j Part 2 e sees somes somes JH Part 3 i 1 1 i 20 E SPOT User Manual Ver 1 ETATIOW www elationlighting com DMX CHANNEL FUNCTIONS AND VALUES ELATION E SPOT III DMX Channel Values Functions Version
21. ister online http www elationlighting com Login aspx to validate your purchase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the return package A brief description of the problem as well as the R A number must also be written down on a piece of paper and included in the shipping container If the unit is under warranty you must provide a copy of your proof of purchase invoice Items returned without a R A number clearly marked on the outside of the package will be refused and returned at customer s expense You may obtain a R A number by contacting Customer support 5 IMPORTANT NOTICE There are no user serviceable parts inside this unit Do not attempt any repairs yourself doing so will void your manufactures warranty Damages resulting from modifications to this fixture and or the disregard of safety and general user instructions found in this user manual void the manufactures warranty and are not subject to any warranty claims and or repairs 5 E SPOT III User Manual Ver 1 ETATiomw www elationlighting com QF 9 9 LIMITED WARRANTY A Elation Professional hereby warrants to the original purchaser Elation Professional products to be free of manufacturing defects in material and workmanship for a period of two years 730 days and Elation Professional product recha
22. message 0 O2Er and O5Er flash repeated 5 times If an error does occur during the initial start up procedure the fixture will self generate a second reset signal and try to realign all the motors and correct the errors If the error persists after a second attempt a third attempt will be made If after a third attempt all the errors have not been corrected the fixture will make the following determinations e 3 or More Errors The fixture cannot function properly with three or more errors therefore the fixture will place itself in a stand by mode until subsequent repairs can be made e Less Than 3 Errors The fixture has less than 3 errors therefore most other functions will work properly The fixture will attempt to operate normally until the errors can be correct by a technician The errors in question will remain flashing in the display as a reminder of internal errors PAN Er Gobo Rot Er TILT Er Prism Er Color Wheel Er Focus Er 24 E SPOT User Manual Ver 1 www elationlighting com CLEANING AND MAINTENANCE 6 A U T O N Disconnect power before cleaning or maintenance CLEANING Frequent cleaning is recommended to insure proper function optimized light output and an extended life The frequency of cleaning depends on the environment in which the fixture operates damp smoky or particularly dirty environments can cause greater accumulation of dirt
23. n PRO DMX Cable AC5PDMX5PRO 5 ft 1 5m 5pin PRO DMX Cable Additional Cable Lengths Available 29 E SPOT User Manual Ver 1
24. nction allows small adjustments to be made to the effect wheels to compensate for ware or in the event a sensor has been knocked slightly out of place Because improper use of this function can result in undesired operation this function has been password protected The password is 050 and must be entered each time the calibration menu function is entered Because calibration is an extremely delicate procedure instructions on performing this action are left out of this manual For a first time calibrator please contact our Customer support team for step by step instructions 17 E SPOT User Manual Ver 1 www elationlighting com EDIT PROGRAM Record Controller The fixture features an integrated DMX recorder by which you can transmit the programmed scenes from your DMxX controller to the moving head Adjust the desired scene numbers via the encoder from to When you call up the scenes at your controller they will automatically be transmitted to the moving head EDIT PROGRAM Record Controller Working With Built In Programs A Master unit can send up to 3 different data groups to the Slave units i e a Master unit can start 3 different Slave units which run 3 different programs The Master unit sends the 3 program parts in a continuous loop Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Part 1 Part 2 Part 3 ad Part 1 Part 2 Part 3 ad Part 1 Part 2 Part 3 1 The Sl
25. on the fixture s optics e Clean the external lens surface at least every 20 days with a soft cloth to avoid dirt debris accumulation e Never use alcohol solvents or ammonia based cleaners MAINTENANCE Regular inspections are recommended to insure proper function and extended life There are no user serviceable parts inside this fixture please refer all other service issues to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections e A detailed electric check by an approved electrical engineer every three months to make sure the circuit contacts are in good condition and prevent overheating e Be sure all screws and fasteners are securely tightened at all times Lose screws may fall out during normal operation resulting in damage or injury as larger parts could fall e Check for any deformations on the housing color lenses rigging hardware and rigging points ceiling suspension trussing Deformations in the housing could allow for dust to enter into the fixture Damaged rigging points or unsecured rigging could cause the fixture to fall and seriously injure a person s e Electric power supply cables must not show any damage material fatigue or sediments Never remove the ground prong from the power cable 25 E SPOT User Manual Ver 1 www elationlighting com TECHNIC
26. racket and safety cable rigging point in one unit see the illustration below When mounting this fixture to truss be sure to secure an appropriately rated clamps to the included omega brackets using a M10 screw fitted through the center hole of the Omega Bracket Be sure to attach the included Safety Cable to the fixture using the safety cable rigging point integrated in the base assembly 1 Omega holders 2 Clamp 3 Safety rope 4 Quick lock fastener SECURING Regardless of the rigging option you choose for your fixture always be sure to secure your fixture with a safety cable The fixture provides a built in rigging point for a safety cable on the hanging bracket as illustrated above Be sure to only use the designated rigging point for the safety cable and never secure a safety cable to a carrying handle 12 E SPOT User Manual Ver 1 www elationlighting com FIXTURE MENU ON BOARD SYSTEM MENU The fixture comes with an easy to navigate system menu The next section will detail the functions of each command in the system menu LCD MENU CONTROL PANEL The control panel see image below located on back of the fixture allows you to access the main menu and make all necessary adjustments to the fixture During normal operation pressing MODE ESC button once will access the fixture s main menu Once in the main menu you can navigate through the different functions and access the sub menus with the
27. rgeable batteries to be free of manufacturing defects in material and workmanship for a period of six months 180 days from the original date of purchase This warranty excludes discharge lamps and all product accessories This warranty shall be valid only if the product is purchased within the United States of America including possessions and territories It is the owner s responsibility to establish the date and place of purchase by acceptable evidence at the time service is sought B For warranty service send the product only to the Elation Professional factory All shipping charges must be pre paid If the requested repairs or service including parts replacement are within the terms of this warranty Elation Professional will pay return shipping charges only to a designated point within the United States If any product is sent it must be shipped in its original package and packaging material No accessories should be shipped with the product If any accessories are shipped with the product Elation Professional shall have no liability what so ever for loss and or or damage to any such accessories nor for the safe return thereof C This warranty is void if the product serial number and or labels are altered or removed if the product is modified in any manner which Elation Professional concludes after inspection affects the reliability of the product if the product has been repaired or serviced by anyone other than the Elation Prof
28. s own packages in the DMX512 data feed and does not influence conventional devices If DMX splitters are used and RDM control is to be used these splitters must support RDM The number and type of RDM parameters depend on the RDM controller being used 16 E SPOT User Manual Ver 1 www elationlighting com PERSONALITY Status Settings Dimmer Mode Select desired DIMMER MODE Standard Stage TV Architectural Theatre 100 l l 50 l 10 0 t 0 255 255 Ramp Effect OS Fade Time 15 Fade Time Trise ms Town ms Tres ms Tarn ma Standard 0 0 0 Stage 780 1100 1540 1660 TV 1180 1520 1860 1940 Architectural 1380 1730 2040 2120 Theatre 1580 1940 2230 2280 EFFECT ADJUST Test Channel Select and auto test each individual channel function independently from the DMX control board EFFECT ADJUST Manual Control Select and manually test and fine adjust each individual channel function Independently from DMX control board This function will center PAN and TILT motors and set dimmer to 100 PAN and TILT functions will still operate if the fixture needs to be positioned to a flat clear surface With the individual functions you can focus the light on a flat surface wall and perform fine adjustments EFFECT ADJUST Calibration eS ONLY QUALIFIED TECHNICIANS SHOULD PERFORM THIS FUNCTION This fu
29. ure the installation area can hold a minimum point load of 10 times the weight of the fixture Fixture installation must always be secured with a secondary safety attachment such as an appropriate safety cable Never stand directly below the device when mounting removing or servicing 10 E SPOT III User Manual Ver 1 www elationlighting com MOUNTING POINTS e Overhead mounting requires extensive experience including amongst others calculating working load limits installation material being used and periodic safety inspection of all installation material and the device If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury e Fixture is fully operational in the specific mounting positions as illustrated below re AX L A ora ls Sa mre VK aig Masco Cp CO 0 o Hilye Gs 2 y S S SASS ZN 6 NZ lt 2 NZ SZ ZS 6 X er PY Noe ay YN ZN LA UZS L SAFETY CABLE ALWAYS USE A SAFETY CABLE WHENEVER INSTALLING THIS FIXTURE IN A SUSPENDED ENVIRONMENT TO ENSURE THE FIXTURE WILL NOT DROP IF THE CLAMP FAILS 1 E SPOT User Manual Ver 1 www elationlighting com CLAMP MOUNTING The fixture provides a unique mounting bracket assembly that integrates the bottom of the base the included Omega B