1. This document hosted by OldWillKnottScales nae 8 6 et SS ig wed 8 ete he to visit us the next time you need a scale Jennings Credit Card 150 User Manual JSCALE CREDIT CARD SCALE MANUAL PLEASE READ COMPLETE INSTRUCTIONS BEFORE USE Thank you for purchasing The Jennings Credit Card Scale With normal care and proper treatment it will provide years of reliable service Please read all operating instructions carefully You can contact us at www Jscale com KEEP THE FOLLOWING POINTS IN MIND If the display becomes locked on Out2 please recalibrate the scale Avoid lengthy exposure to extreme heat or cold your scale works best when operated at normal room temperature Always allow the unit to acclimate to a normal room temperature for at least one hour before use Allow sufficient warm up time Turn the scale On and wait several seconds to give the internal components a chance to stabilize before weighing The cleaner the environment the better Dust dirt moisture vibration air currents and proximity to other electronic equipment can all cause an adverse effect on the reliability and accuracy of your scale Handle with care Gently apply all items to be weighed onto tray top Although this scale is designed to be quite durable try to avoid rough treatment as this may permanently damage the internal sensor and void your warranty Avoid shaking dropping or otherwise shocking the scale This is a precision instrument a
2. cates low batteries However sometimes it also may indicate a serious zero mark error This means when you turn the scale on it can t determine what zero is a slight zero mark error will cause situation 1 above Thus if new batteries do not fix this error the scale will have to be sent to us for replacement under our 5 year warranty program 4 If the display shows UNST this means the scale is not stable Please try operating the scale ona more stable surface and be sure nothing is on the tray or stuck under the tray when you turn it on If this situation persists it may be an indication of fatal load cell damage Try calibrating the scale if this does not work please follow the warranty instructions Although the JS is designed to be extremely durable It s important that you never overload or drop shock the scale Scales are delicate instruments and unlike Cellular phones scales have delicate sensors that determine how much an item weighs If you drop or shock your scale these sensors feel the shock and are sometimes destroyed This happens with all digital scales We design our scales to be as resistant to shock or drops as possible however there is no way for us to protect 100 against load cell or sensor damage A well treated scale will provide years of reliable and accurate weighing However an abused scale will only work until it s sensors are damaged
3. nd MUST BE HANDLED WITH EXTREME CARE Only operate the scale on a stable vibration free surface IMPORTANT Do not operate near cell phones radios computers or any other electronic device These electronic scale are precision instruments Do not operate near an in use cell phone cordless phone radio computer or other electronic device These devices emit RF and can cause unstable scale readings If your scale ever performs poorly try moving the scale to a different room or location This is a very precise scale the display may seem to wander or jump when weighing This is due to air currents or vibrations Stable weighing is achieved when the display remains fixed for 3 seconds OPERATION Battery Operation 1 Two CR2032 batteries are required 2 To install batteries a Release the battery cover by sliding out sideways b Place batteries into battery compartment aligned correctly c Replace battery cover DO NOT USE EXCESSIVE FORCE amp DO NOT PRESS ON THE TRAY 3 The scale is now ready for battery operation Advanced users only CALIBRATION IMPORTANT This scale was professionally factory calibrated before shipment and does NOT need to be recalibrated by the end user However if you wish to recalibrate your scale we provide these instructions for calibration Repeat calibration if the scale ever shows Out2 Incorrect calibration can occur if you do not follow the steps exactly If your scale does not perform accurately
4. ore operation ZERO TARE After the scale is ON you can press TARE to reset the scale to zero This can be used for eliminating from a sample or a Tray Container the weight value of a container weight is permanently removed for the remainder of the procedure Just tum the scale ON place the tray or container on weighing platform and press the TARE key The scale will show 0 0 or 0 00 on the display and you can add items to the container tray NOTE When all weight are removed from the weighing tray the tared value of a container will be displayed as a negative number Cycle the power on the scale or press the TARE key to reset the scale to zero These electronic scale are precision instruments Avoid disturbing environmental conditions such as currents vibrations strong electrical and magnetic fields as well as a rapid change of the ambient temperature TROUBLESHOOTING amp OPERATION NOTES 1 If the Display ever becomes locked showing Out2 please recalibrate the scale as outlined in the manual 2 If the Display ever becomes locked on LLLL or EEEE this indicates that the scale was shocked dropped or otherwise damaged and the delicate weighing sensors have been damaged You can try recalibrating the scale If the sensor has not been hurt too badly it will work again after recalibration Otherwise you will have to follow the warranty instructions that came with your scale 3 If the display becomes locked on 8888 this often indi
5. play will appear as shown below This display will remain for approximately 2 seconds and then reset to 0 1 8 8 8 8 Overload When an applied load exceeds the capacity EEEE will appear on the display Remove the excessive load immediately Remember You can permanently damage the scale by overloading it Negative Value Any tarred value or a value left in memory will be displayed as a negative number once all weight is removed from the unit Press tare to re Zero the unit Auto off An auto shut off feature is provided to conserve battery power The unit will automatically turn off after approximately 3 minutes of inactivity KEY PAD FUNCTIONS MODE Unit mode selection Press and hold the left key to change weight unit You can select g grams oz ounces dwt pennyweight or ct carats ON OFF Press this key to tum unit on Once the unit is on press and hold the same key for 5 seconds to tum the scale off Tray Operation The sliding tray of the CCS is designed to protect the scale from accidental overload when it is closed Simply slide the cover off of the scale and place it upside down on the tray This way you can use it as an expansion tray or to hold loose items Note if you wish to re zero the scale simply press the TARE key To close the cover simply reinstall it sliding it back into place from back to front NOTE Always close the cover when storing the scale Please be sure the cover is fully open bef
6. please try replacing your batteries before you calibrate You will need a 100gram weight to calibrate this scale NOTE if you do not have access to a 100g weight you can purchase one at your local store or in emergency situations you can use 100g of coins or weights ie 20 US Nickels 100g as a 100g weight 1 Turn the scale OFF and Place the it on a Flat very stable surface Be certain the scale is OFF 2 Press and hold the TARE key for 10 seconds until a random large number appears on the display then release the key 3 Press amp release the TARE key again the display will show 2Ero and then 100 0 4 Gently place a 100 gram weight on the scale and wait 3 seconds 5 Press the TARE key The display will show CAL and then PASS calibration is complete Remove the weight then Press and hold the key for 5 seconds to turn the scale off NOTE if after calibration your scale does not read accurately this indicates calibration error and the calibration process should be repeated more slowly Please calibrate on a very stable flat surface INACCURACY ERROR The primary reasons for inaccuracy or malfunction are low batteries incorrect calibration overload or operating on an unstable surface Please keep this in mind and maintain and operate your scale properly The scale is a precise instrument and must be handled with the upmost care and caution FEATURE Power Up Segment Test When first turning the unit on all segments of the dis