Home

product catalogue

image

Contents

1. 11 W PLL 18 W PLL 24 W PLL 36 W PLL 55 W PLL ECOM PLL 30 17 16 13 11 optional rss O P 9 9 C9 62 G0 69 C2 C2 BATTERY DATA RY DATA VOLTAGE CAPACITY CELL TYPE CELL SIZE mm QTY OF CELLS DIMENSIONS mm WEIGHT kg In accordance with EN 61347 1 EN 61347 2 3 and EN 61347 2 7 kg 6V 1800 mAh SE 2 5 DIX225X23 0 250 6 V 4000 mAh D 35 5 35x3 10x35 0 650 6V 5000 mAh D 35 5 35x83 10X35 0 800 TECHNICAL DATA Please refer to Battery Details Table in Emergency Lighting Unit Overview section of the catalogue for further battery information SUPPLY VOLTAGE 230 VAC 50 60 Hz EMERGENCY LUMEN FACTOR BLF gt 10 AMBIENT TEMPERATURE 10 50 C BALLAST LUMEN FACTOR gt 75 CASING TEMPERATURE TOSC ENERGY EFFICIENCY INDEX RATED DURATION 1 3h PROTECTION CLASS IP 20 BATTERY CHARGING TIME 24 48h INSULATION CLASS II WIRING DIAGRAM TECHNICAL DRAWING PRODUCTLIST LIST PRODUCT RATED LAMP LAMP BALLAST CODE DURATION POWER TYPE POWER FACTOR ECOM PLL 111 1H Ih 1x11 W 4 pin PLL 0 70 ECOM PLL 111 3H 3h 1x11 W 4 pin PLL 0 70 e E ECOM PLL 118 1H Ih 1x18 W 4 pin PLL 0 70 N N bes A ECOM PLL 118 3H 3h 1x18 W 4 pin PLL 0 70 E switched Line 5 ECOM PLL 124 1H Ih 1x24 W 4 pin PLL 0 70 L Unswitched Line ECOM PLL gt T ECOM PLL 124 3H 3h 1x24 W 4 pin PLL 0 70 N Neutral ECOM PLL 136
2. 100 RATED DURATION 1h PROTECTION CLASS IP 20 J PRODUCTLIST LIST PRODUCT BATTERY RATED MAINS CASE DIMENSIONS WEIGHT QTY in CODE CAPACITY POWER W CURRENT A mm kg a EMLUS 12V 015W 12 V 1600 mAh 1 h 4 4 0 025 39x221x34 0 235 30 EMLUS 12V 050W 12 V 5000 mAh 1 h 7 2 0 036 39x221x34 0 235 30 Measured under 230 V mains Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice BATTERY DATA RY DATA DIMENSIONS WEIGHT E M E RG E N CY LI G H 5 U N _ L E D VOLTAGE CAPACITY CELL TYPE ET QTY OF CELLS ko EMLUS 24V ABR Sx 00 24V 1600 mAh 5 23 20 46 225 46 24V 5000 mAh D 35 20 70x310x70 2 600 Please refer to Battery Details Table in Emergency Lighting Unit Overview section of the catalogue for further battery information WIRING DIAGRAM TECHNICAL DRAWING EMLUS 24V Switched Line Unswitched Line Neutral LED Driver a l 69 9 6 69 9 9 69 In accordance with 61347 1 EN 61347 2 7 and 60929 TECHNICAL DATA AMBIENT TEMPERATURE 10 C 50 C EMERGENCY LUMEN FACTOR BLF 10096 RATED DURATION 1h PROTECTION CLASS IP 20 PRODUCTLIST LIST PRODUCT BATTERY RATED MAINS CASE DIMENSIONS WEIGHT POWER W CURRENT A mm EMLUS 24V 030W 24 V 1600 mAh 1 h
3. Es EE In accordance with EN 60598 1 EN 60598 2 22 standards TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz SIGN DIMENSIONS WES 74ers AMBIENT TEMPERATURE 10 40 C VIEWING DISTANCE 29m RATED DURATION 3h PROTECTION CLASS 20 BATTERY CHARGING TIME 24h INSULATION CLASS 3 6 V NiCd CONTROL PANEL CHARGE Charge Status Display LED Indicates charging process of the battery WI TEST Test Button Enables testing the product without mains cuts Ml FULL Battery Status Display LED Indicates the occupancy level of the battery PRODUCT LIST LIST PRODUCT RATED OPERATING LIGHT ROUTING TYPE CODE DURATION MODE SOURCE MODE OF MOUNTING BYALO3Y CY SU Maintained 6 X 0 1W LED Double sided Surface Mounted Plastic Hanger BYALO3Y CY MT 3h Maintained 6 X 0 1W LED Double sided Surface Mounted Metal Hanger BYALO3Y CY SA 3h Maintained 6X0 1W LED Double sided Recessed Mounted BYALO3Y TY SU 3h Maintained 6 X 0 1W LED Single sided Surface Mounted Plastic Hanger BYALO3Y TY MT 3h Maintained 6 X 0 1W LED Single sided Surface Mounted Metal Hanger BYALO3Y TY SA 3h Maintained 6 X 0 1W LED Single sided Recessed Mounted Maintained Lights on mains and stays alight in case of the mains failure MAINS DATA DATA PRODUCT RATED POWER MAINS CURRENT DIMENSIONS WEIGHT QTY in CODE W A mm kg BOX BYALO3Y CY SU 28 0 016 42x276x203 0 635 1
4. 171 STANDARDS amp ICONS oes EN 61347 1 EN 61347 2 7 EN 61347 2 13 EN 62031 EN 60598 1 EN 60598 2 22 EN 62384 EN 60929 EN 61347 2 3 EN 62471 EN 1838 EN 50172 EN ISO 7010 ISO 3864 1 ISO 16069 EN 55015 EN 61547 General and safety requirements for lamp control gear Lamp controlgear Part 2 7 Particular requirements for battery supplied electronic control gear for emergency lighting self contained Particular requirements for d c or a c supplied electronic control gear for LED modules Safety specifications for LED modules General requirements and test for luminaires Part 1 General requirements and tests Particular requirements in respect of luminaires for emergency lighting DC or AC supplied electronic control gear for LED modules Performance requirements AC and or DC supplied electronic control gear for tubular fluorescent lamps Performance requirements Lamp control gear Part 2 3 Particular requirements for a c and or d c supplied electronic control gear for fluorescent lamps Photobiological safety of lamps and lamp systems Lighting applications Emergency lighting Emergency escape lighting systems Graphical symbols Safety colours and safety signs Registered safety signs Graphical symbols Safety colours and safety signs Graphical symbols Safety signs Safety way guidance systems SWGS Limits and methods of measurement of radio disturbance ch
5. 188 _ 211 Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice oo CD PRODUCT LIST _ es RG E N CY EXIT LU M LE D PRODUCT RATED OPERATING LIGHT ROUTING TYPE TUNA M BYALOS CODE DURATION MODE SOURCE MODE OF MOUNTING BYAL M08 CY SU 3h Maintained 8 x 0 1W LED Double sided Surface Mounted Plastic Hanger BYAL M08 CY MT 3h Maintained 8 x 0 1W LED Double sided Surface Mounted Metal Hanger BYAL M08 CY SA 3h Maintained 8x0 1W LED Double sided Recessed Mounted Maintained Lights on mains and stays alight in case of the mains failure Double Sided Anodized aluminum case MAINS DATA NS DATA Non flammable ABS side cover and hanger QTY in MD LED applicati PRODUCT RATED POWER MAINS CURRENT DIMENSIONS WEIGHT CODE W A mm CARTON Charge and battery capacity status display with green LEDs BOX Test switch BYAL M08 CY SU oS 0 020 LOX 274x195 0 665 1 High temperature Ni Cd battery cells BYAL M08 CY MT 3 5 0 020 40 x 274 x 195 0 745 1 and deep discharge protection BYAL M08 CY SA 35 0 020 102x 3242 x125 T220 1 Transparent Plexiglas with 8 printed Measured under 230 V mains Side lighting Ceiling mounted ceiling recessed or wall mounted Optional application of 110 V operating voltage Optional metal hanger or hook RECESSED MOUNTING HOLE SIZE WIRIN
6. EMLUS 12V Compatible With ECOM PW Compatible With SEED e Power LED spot 8 e LED Stick gt e Power LED A E N ee e LED Spot Lamp e LED Spot Lamp v Sras QU EMLUS 12V is suitable for LED strip applications up to 12 V 50 W It provides the same light ECOM PW is designed for serial power LED applications between 1 7 It is suitable for 1 W 2 W and as in operation on main power in the case of emergency 3 W power LED applications It provides 85 of the light it gives in operation on main power in the case of emergency EMERGENCY LIGHTING UNIT SOLUTIONS FLUORESCENT LAMP EMLUS PLL Compatible With Compatible With sa 7 gt EMLUS T5 is suitable for 4 pin T5 fluorescent lamps EMLUS PLL 15 suitable for 4 pin PLL fluorescent lamps It is compatible with electronic and mechanic ballasts It is compatible with electronic and mechanic ballasts EMLUS T8 Compatible With EMLUS PLC Compatible With EMLUS T8 is suitable for 4 pin T8 fluorescent lamps EMLUS PLC is suitable for 4 pin PLC fluorescent lamps It is compatible with electronic and mechanic ballasts It is compatible with electronic and mechanic ballasts Compatible With e 5 Circular Fluorescent Lamp e 5 Fluorescent Lamp wer ECOM T5 is designed for lighting 4 pin T5 fluorescent lamps on main power and in the case of emergency It is the combination of Emergency Lighting Unit and Electronic Ballast It lights one lamp connected to it
7. LP ECOM PW 2X3W 1H 9 6 900 mh 1 h 10 2 0 074 42 264 34 0 275 30 Integrated LED driver and emergency lighting unit in the same ECOM PW 2X3W 2H 9 6V 1600 mAh 2 h 10 6 0 078 42 264 934 0 275 20 Compatible with LED lighting and COB LED ECOM PW 3X1W 2H 9 6V 900 mAh 2 h 58 0 049 42 264 34 0 271 20 Non maintained operation ECOM PW 3X1W 4H 9 5 V 1600 mAh 4 h 7 1 0 052 42 264 34 0 271 30 Constant current output ECOM PW 3X2W 1H 9 6V 900 mAh 1 h 10 0 0 074 42x264x34 0 271 30 Short circuit protection and isolated output ECOM PW 3X2W 3H 9 6 V 1600 mAh 3 h 10 3 0 077 42x264x34 0 271 30 Emergency lighting function by Interruption of the unswitched phase ECOM PW 3X3W 1H 9 6V 900 mAh 1 h 13 1 0 097 42x264x34 0 271 30 1 2 3 4h duration ECOM PW 3X3W 2H 9 6V 1600 mAh 2 h 137 0 100 42x264x34 0 271 30 Emergency lighting function in case of low voltage ECOM PW 4X1W 2H 14 4 V 900 mAh 2 h 8 4 0 060 42x264x34 022 30 Driving LED by semi constant current method ECOM PW 4X1W 4H 14 4 V 1600 mAh 4 h 9 4 0 063 42x264x34 0 292 30 Driving of 1 to 7 serially connected LED pieces ECOM PW 4X2W 1H 14 4V 900 mAh 1 h ie 0 090 42x264x34 022 30 Short circuit open circuit and overload protection ECOM PW 4X2W 3H 144 V 1600 mAh 3 h 14 0 093 42x264x34 0 292 30 High temperatu re Ni Cd battery cells ECOM PW 5X1W 2H 19 2 V 900 mAh 2 h 10 6 0 069 42x264x34 0 301 30 Overcharge and deep discharge protection ECOM PW 5X1W 4H 19 2 V 1600 mAh 4 h 1
8. main power and in the case emergency It is the combination of Emergency Lighting Unit and Electronic Ballast It lights one lamp connected to its ends on main power and in the case of emergency with its internal ballast Compatible With e PLL Compact Fluorescent Lamp ECOM2 PLL is designed for lighting 4 pin PLL fluorescent lamps on main power and in the case of emergency It is the combination of Emergency Lighting Unit and Electronic Ballast With its internal ballast on main power it lights two lamps connected to its ends and the case of emergency 11 lights only one of these lamps Compatible With e PLC Compact Fluorescent Lamp ECOM PLLC is designed for lighting 4 pin PLC fluorescent lamps on main power and in the case of emergency It is the combination of Emergency Lighting Unit and Electronic Ballast It lights one lamp connected to its ends on main power and in the case of emergency with its internal ballast Compatible With e PLC Compact Fluorescent Lamp ECOM2 PLC is designed for lighting 4 pin PLC fluorescent lamps on main power and in the case of emergency It is the combination of Emergency Lighting Unit and Electronic Ballast With its internal ballast on main power it lights two lamps connected to its ends and in the case of emergency it lights only one of these lamps Compatible With e Spot Halogen Lamp 2 G9 Halogen fea gt b Lam gy Mf ez f e AR 111 Halog
9. Emergency Lighting Unit Overview section of the catalogue for further battery information RATED DURATION 1 3h PROTECTION CLASS IP 20 BATTERY CHARGING TIME 24 48h INSULATION CLASS II EMERGENCY LUMEN FACTOR BLF 2 20 WIRING DIAGRAM TECHNICAL DRAWING PRODUCTLIST LIST E LED Driver PRODUCT OUTPUT LED MODULE OUTPUT LED CURRENT LEDQUANTITY OUTPUT POWER CODE CURRENT VOLTAGE RANGE TOLERANCE il EMLUS LED 01 20V 70 mA 1 20 VDC 5 1 2 Lo k 2 EMLUS LED 21 40V 65 mA 21 40 VDC 5 8 13 LED 2 2 W 5 A ot EMLUS LED 41 60V 60 mA AJENO 5 EIS 34W eee EMLUS LED 61 90V 40 mA 61 90 VDC 5 21 30 LED 3 3 W EMLUS LED m EMLUS LED 91 150V 35 mA 91 150 VDC 5 31 50 LED 4 5 W L Unswitched Line Measured using maximum LED quantities with 4 8 V battery Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice BATTERY AND MAINS DATA AND MAINS DATA R G F N CY LI G 5 U N L D PRODUCT BATTERY RATED MAINS CASE DIMENSIONS WEIGHT an CODE CAPACITY POWER W CURRENT mm kg BOX EMLUS XLED EMLUS XLED150 01 21V 22 3 5 0 020 39x216x38 0 272 20 I I 7 2V 2200 mAh 3h 7 2V 1600 mAh 1 h EMLUS XLED150 22 36V 72V 000 mAh 3h 3 5 0 020 39x216x38 0 272 20 7 2V 2200 mAh 1 h EMLUS XLED150 37 60V 72 5000 mAh 3
10. T5 Single Lamp Electronic Ballast EMLUS T5 28 80 3H 3h 28 35 49 80 W 4 5 Single Lamp EMLUS T5 213 14 1H 1h 2x13 14 W 4 pin T5 Double Lamp EMLUS T5 213 14 3H 3 h 2x13 14 W 4 pin T5 Double Lamp Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice EMERGENCY LIGHTING UNIT F L U O R E S C F N L A M D PRODUCT BATTERY RATED MAINS CASE DIMENSIONS WEIGHT on CODE CAPACITY POWER W CURRENT A mm kg BOX EMLUS T8 EMLUS T8 15 58 1H amp V 1800 mAh 38 0 020 43x185x34 0 238 30 EMLUS T8 15 36 3H 6V 4000 mAh 4 3 0 022 43x185x34 0 242 30 EMLUS T8 58 3H 6V 5000 mAh 5 2 0 027 43x185x34 0 257 30 EMLUS T8 215 18 1H 7 2V 2200 mAh 4 2 0 021 43x185x34 0 236 30 EMLUS T8 215 18 3H 7 2 V 6000 mAh 5 7 0 028 43x185x34 0 255 30 Compatible with electronic and magnetic ballast Non maintained operation Emergency lighting function by interruption of the unswitched phase 1 3h duration Emergency lighting function in case of low voltage Single or double lamp preference in case of emergency Compatible with 4 pin fluorescent lamps EMERGENCY LUMEN FACTOR BLF M E RG N CY LU M N FACTO R B L Prolonging the lamp life with warm start Short circuit open circuit and overload protection PRODUCT 15W T8 18W T8 30W T8 36W T8 58W T8 High temperature Ni Cd battery cells Overcharge and deep discharge protection Polarity reversal protection for battery
11. 220 Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice PRODUCT LIST EMERGENCY EXIT LUMINARY LED m SOMON LED BYPLO1 LED CODE DURATION MODE SOURCE MODE OF MOUNTING BYPLO1I S LED 1 3h Maintained 20 X 0 1 W LED Single sided Wall Mounted Maintained Lights on mains and stays alight in case of the mains failure Non Maintained Lights in case of the mains failure MAINS DATA PRODUCT RATED POWER MAINS CURRENT DIMENSIONS WEIGHT 4 CODE WJ A mm kg BOX ss BYPLO11 A LED 3H 23 0 022 104x340x67 0 808 1 BYPL01I S LED 3H 7 6 0 038 104x340x67 0 855 1 Measured under 230 mains TECHNICAL DRAWING WIRING DIAGRAM Please refer to Pictogram Table in Emergency Exit Luminaries Overview section of the catalogue for alternatives Y A A OSRAM Unswitched Line RoHS LED LED Technology included Swi tche d Line Neutral 230 VAC N E E Es EE In accordance with EN 60598 1 EN 60598 2 22 standards TECHNICAL DATA AMBIENT TEMPERATURE 10 40 C VIEWING DISTANCE 20m BATTERY CHARGING TIME 24 48h INSULATION CLASS II CONTROL PANEL PANEL CHARGE Charge Status Display LED Indicates charging process of the battery W TEST Test Button Enables testing the product without mains cuts B FULL B
12. 3 6 24 VDC s ER mee RATED DURATION 1 4h PROTECTION CLASS IP 20 Please refer to Battery Details Table in Emergency Lighting Unit Overview section of the catalogue for further battery information BATTERY CHARGING TIME 24 148 h INSULATION CLASS WIRING DIAGRAM TECHNICAL DRAWING PRODUCTLIST LIST PRODUCT BATTERY RATED MAINS CASE DIMENSIONS WEIGHT CODE CAPACITY POWER W CURRENT A mm kg L ECOM PW 1X1W 2H 3 6 V 900 mAh 2 h 2 9 0 023 42x264x34 0 265 30 N ECOM PW 1X1W 4H 3 6 V 1600 mAh 4 h 3 0 0 024 42x264x34 0 265 30 ECOM PW 1X2W 1H 3 6 V 900 mAh 1 h 4 4 0 035 42 264 34 0 268 30 S Switched Line ECOM PW 1X2W 3H 3 6 V 1600 mAh 3 h 4 7 0 037 42x264x34 0 268 30 Unswitched Line ECOM PW 1X3W 1H 3 6 V 900 mAh 1 h 5 5 0 045 42x264x34 0 268 30 ECOM PW 1X3W 2H 3 6 V 1600 mAh 2 h 5 7 0 047 42 264 34 0 208 30 N Neutral Bes reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice EMERGENCY LIGHTING UNIT F L U 0 R ES C E N LA M PRODUCT BATTERY RATED MAINS CASE DIMENSIONS WEIGHT 2 CODE CAPACITY POWER W CURRENT A mm kg BOX EM LUS T5 EMLUS T5 06 08 1H 3 6 V 1000 mAh 1 4 0 013 BIXZ2 SA 0 185 30 EMLUS T5 06 08 3H 3 6 V 3000 mAh 2 1 0 015 99x221x34 0 185 30 EMLUS T5 13 54 1H 6V 1800 mAh 2 0 016 SIXZZIXSA 0 215 30 EMLUS T5 13 24 3H 6V 4000 mAh 3 5 0 018 39x221x
13. 0 100 592x22 x54 0 285 30 High temperature Ni Cd battery cells ECOM T5 11314 3H 6 V 4000 mAh 18 0 110 39x221x34 0 285 30 Overcharge and deep discharge protection ECOM T5 12124 1H 6 V 1800 mAh 22 0 130 37x22 1X34 0 290 30 Polarity reversal protection for battery 5 12124 3 V 4000 mAh 23 0 140 39x221x34 0 290 30 Charge status display with green LED ECOM T5 12835 1H 7 2 V 2200 mAh 30 0 195 3772234 0 295 30 Optional test switch ECOM T5 12835 3H 7 2 V 6000 mAh 31 0 205 39x221x34 0 295 30 Optional application of 110 V operating voltage ECOM T5 139 1H 6 V 1800 mAh 30 0 220 39x22 0 310 30 ECOM T5 139 3H 6 V 5000 mAh 36 0 230 39 221 34 0 310 30 Shane ss ECOM T5 149 1H 7 2 V 2200 mAh 30 0 220 39X22 0 310 30 5 149 3 7 2 V 6000 mAh 40 0 260 39 221 34 0 310 30 5 154 1 6 V 1800 mAh 35 0 220 0 310 30 5 154 3 6 V 5000 mAh 36 0 230 39 221 34 0 310 30 5 180 1 7 2 V 2200 mAh 45 0 250 37222934 STO 30 ECOM T5 180 3H 7 2 V 6000 mAh 49 0 300 39 221 34 0 310 30 i RYHS TL5 4P Measured with maximum power under 230 V mains OOOOOO OOO EMERGENCY LUMEN FACTOR PRODUCT 8W T5 14W T5 21W T5 24W T5 28W T5 35W T5 39W T5 49 5 54W T5 80W T5 In accordance with EN 61347 1 EN 61347 2 3 EN 61347 2 7 ECOM T5 30 25 17 18 16 15 16 15 13 10 BATTERY DATA ERY DATA VOLTA
14. 6 3 0 033 39x221x34 0 235 30 EMLUS 24V 100W 24 V 5000 mAh 1 h 0 036 39 221 34 0 235 30 Measured under 230 V mains Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice BATTERY DATA EMERGENCY LIGHTING UNIT LED VOLTAGE CAPACITY CELL TYPE a ee QTY OF CELLS IM I De WEIGHT mm mm LUS u 2 2 OV 3000 mAh E 26 6 26x294x26 0 480 7 2V 6000 mAh D 39 6 29 272 33 1 140 12N 3000 mAh C 26 10 52 245 26 0 800 12V 4000 mAh D 29 10 70x310x35 1 300 12 5000 mAh D S5 10 JUXS 10x35 1 600 12V 6000 mAh D 22 10 70x310x35 1 900 su 12N 8000 mAh D 25 20 70x3 10x70 2 600 Compatible with 220 V LED tube and spot lighting 12V 10000 mAh D 35 20 70x310x70 3 200 Sustained constant 100 lighting Non maintained operation Please refer to Battery Details Table in Emergency Lighting Unit Overview section of the catalogue for further battery information Emergency lighting function by interruption of the unswitched phase 1 3h duration Emergency lighting function in case of low voltage DC voltage supply for LED Driver Short circuit open circuit and overload protection High temperature battery cells Overcharge and deep discharge protection WIRING DIAGRAM TECHNICAL DRAWING Polarity reversal protection for battery Charge status display with green LED Optional test switch Anodized aluminum case Simple connectable termi
15. Charge status display with green LED Optional test switch Optional application of 110 V operating voltage Non flammable ABS case Simple connectable terminal block BATTERY DATA RY DATA Measured under 230 V mains EMLUS T8 16 15 12 11 10 VOLTAGE CAPACITY CELL TYPE CELLSIZE mm QTYOF CELLS DIMENSIONS mm WEIGHT kg 6V 1800 mAh SC 23 5 23x225x23 0 250 RYHs lt gt il Ir 6 V 4000 mAh D 35 5 35x310x35 0 650 9 TL D 4P 6V 5000 mAh D 35 5 35x310x35 0 800 6 7 2 V 2200 mAh SC 23 23x270x23 0 360 230 VAC VO TON 6000 mAh D 35 6 2X09 1 140 Please refer to Battery Details Table in Emergency Lighting Unit Overview section of the catalogue for further battery information In accordance with EN 61347 1 EN 61347 2 7 and EN 60929 TECHNICAL DRAWING TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz BATTERY CHARGING TIME 24 48 h E a AMBIENT TEMPERATURE ta 10 C 50 C EMERGENCY LUMEN FACTOR BLF gt 10 E gt CASING TEMPERATURE ROSE PROTECTION CLASS IP 20 bes A e RATED DURATION 1 3h INSULATION CLASS H EMLUS T8 L Switched Line Unswitched Line N Neutral Emergency Lamp PRODUCTLIST LIST PRODUCT RATED LAMP LAMP PERSE CODE DURATION POWER TYPE ur EMLUS T8 15 58 1H 1h 15 18 30 36 58 W 4 8 Single Lamp j EMLUS T8 15 36 3H 3h 15 18 30 36 W 4 T8 Single Lamp bes A 2 EMLUS T8 58 3H 3h 58 4
16. EMLUS PW 9X3W 2H 28 8 V 1600 mAh 2 h 6 3 0 032 39 221 34 0 242 30 m AA Measured under 230 V mains RoHS LED BATTERYDATA 50 60 Hz ABS VOLTAGE CAPACITY CELL TYPE CELL SIZE QTY OF CELLS DIMENSIONS WEIGHT mm mm kg In accordance with EN 61347 1 EN 61347 2 7 and EN 60929 3 6 V 700 mAh 14 5 3 14 9x90x14 9 0 084 3 6 1600 mAh SC 23 3 23x135x23 0 135 9 6 V 900 mAh AA 14 5 8 50x58x29 0 224 9 6 V 1600 mAh SC 23 8 46x180x23 0 360 14 4 V 900 mAh AA 14 5 50 87 29 0 336 TECHNICAL DATA 14 4 V 1600 mAh SC 23 12 46x135x46 0 540 19 2V 900 mAh AA 14 5 16 50x116x29 0 448 SUPPLY VOLTAGE 230 VAC 50 60 Hz EMERGENCY LUMEN FACTOR BLF 85 19 2 V 1600 mAh SC 23 10 46x180x46 0 720 AMBIENT TEMPERATURE ta 10 50 C MAX OUTPUT POWER 9x3W 24V 900 mAh AA 14 5 20 50x145x29 0 560 CASING TEMPERATURE Oe OUTPUT VOLTAGE 3 6 28 8 VDC 24V 1600 mAh SC 23 20 46x225x46 0 900 RATED DURATION 172748 PROTECTION CLASS IP 20 28 8 V 900 mAh AA 14 5 24 50x174x29 More BATTERY CHARGING TIME 24 48h INSULATION CLASS 28 8 V 1600 mAh ep 23 24 69x180x46 1 080 Please refer to Battery Details Table in Emergency Lighting Unit Overview section of the catalogue for further battery information WIRING DIAGRAM TECHNICAL DRAWING PRODUCTLIST LIST Le PRODUCT BATTERY RATED POWER MAINS CURRENT CASE DIMENSIONS WEIGHT ALIUM N CODE CAPACITY W A mm g BOX LED EM
17. Electronic ballast that be dimmed A2 Electronic ballast with low loss A3 Standard electronic ballast B1 Magnetic ballast with extra low loss B2 Magnetic ballast with low loss C Magnetic ballast with normal loss D Magnetic ballast with high loss ELECTRONIC BALLAST amp ELECTRONIC TRANSFORMER OVERVIEW BALLAST TYPES There are two types of ballasts Magnetic Ballast Magnetic ballast is the oldest and the most conventional ballast type Its use has been decreasing rapidly day by day Basically it consists of elements such as copper coil and siliceous sheet and it generally has a simple structure without any electronic components Electronic Ballast Electronic ballast can be analyzed under two main categories as hot ignition and cold ignition Hot ignition ballast can increase the life of the lamp significantly by means of ignition after heating the cathodes for a while before igniting the lamp ADVANTAGES OF ELECTRONIC BALLAST OVER MAGNETIC BALLAST Electronic ballasts are at minimum 35 more efficient during their life than magnetic ballasts and they provide savings for years due to this difference in the consumption Energy Savings Electronic ballasts create the required operating parameters for fluorescent lamps by using less energy compared to magnetic ballasts due to their functioning in high frequencies Long Lamp Life The lamp life is related more to the on off count than to the catalogue value
18. TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz LIGHT SOURCE 20 pcs SMD LED AMBIENT TEMPERATURE ta 10 40 C DIFFUSER Polycarbonate Glass RATED DURATION ea PROTECTION CLASS IP 44 BATTERY CHARGING TIME 24h INSULATION CLASS 3 6 V NiCd PRODUCTLIST LIST PRODUCT RATED OPERATING LIGHT LIGHT INTENSITY on TYPE of BATTERY CODE DURATION MODE SOURCE ENERGY EMERGENCY MOUNTING e BYPLO1I A LED ish Non Maintained 2WLED 150lm Surface Mounted 24 48h BYPLO1I S LED 1 3h Maintained 2W LED 150 150 lm Surface Mounted 24 48h BYPLO1 A LED SA ds Non Maintained 2WLED 150 lm Recessed 24 48 h BYPLO1I S LED SA 1 3h Maintained 2 W LED 150 Im 150 Im Recessed 24 48h Maintained Lights on mains and stays alight in case of the mains failure Non Maintained Lights in case of the mains failure _ MENTEM PRODUCT RATED MAINS DIMENSIONS WEIGHT QTY in CODE POWER WJ CURRENT A mm kg CARTON BYPLO1I A LED 1H 2 0 0 018 104x340x67 0 640 1 BYPLO1I A LED 3H 2 3 0 022 104x340x67 0 810 1 BYPLO1I S LED 1H 7 3 0 034 104x340x67 0 690 1 BYPLO1I S LED 3H 7 6 0 038 104 340 67 0 860 1 BYPLO1I A LED SA 1H 2 0 0 018 148x426x67 1 100 1 BYPLO1I A LED SA 3H 2 3 0 022 148x426x67 1 270 1 BYPLO1I S LED SA 1H 7 3 0 034 148x426x67 1 150 1 BYPLO1I S LED SA 3H 7 6 0 038 148x426x67 1 320 1 Measured under 230 V mains WIRING DIAGRAM RECESSED MOUNTING HOLE SIZE Unswitched Line Switched L
19. min PRODUCTLIST LIST PRODUCT SUPPLY VOLTAGE PANEL DRIVING PANELLIGHT TOTAL LUMINOUS HOMOGENEITY DIMENSIONS WEIGHT CODE VDC CURRENT mA POWER W FLUX lm DISTANCE mm mm kg LPN E 2413E5 12 4 1050 1250 99 240 x 240 0 090 LED panels must be driven by constant current LED drivers Homogeneity distance was measured with 1 5 mm opal Plexiglas 30x120 Luminary Application 60x60 Luminary Application WIRING DIAGRAM Phase Neutral L o 2 o Constant Current Nc N LED Driver Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice PANEL APPLICATIONS TECHNICAL DRAWING 151 STICK APPLICATIONS APPLICATIONS LED STICK LST TECHNICAL DRAWING WIRING DIAGRAM A 3332 1 2 CE aXus AA OSRAM L E D LED Technology included FRA PCB In accordance with EN 62031 and EN 62471 TECHNICAL DATA AMBIENT TEMPERATURE 10 50 C LUMINOUS EFFICACY 97 115 lm W PRODUCTLIST LIST PRODUCT FLUORESCENT SUPPLY STICK DRIVING LED STICK LED STICK DIMENSIONS WEIGHT CODE EQUIVALENT VOLTAGE CURRENT mA LIGHT POWER W LUMINOUS FLUX Im mm kg 5 1 3805 3 36 W 8 3 22 235 5 17 565 20 384 0 031 51 2706 5 18 W 2 22 250 5 9 605 20x 273 0 025 L5T 3811E5 54 W 5 3 46 5 239 10 92 1200 20 x 378 0 027 In order to achieve the
20. 0 245 25 EB DF1 PLC 218 2 x 18W PLC 0 99 44 0 405 42x264x34 0 245 25 TECHNICAL DATA EB DF1 PLC 226 2x26W PLC 0 99 57 0 520 42 264 34 0 245 25 EB DF1 PLC 23242 2 Xx 32W PLC 0 99 61 0 555 42x264x34 0 250 2 SUPPLY VOLTAGE 110 VAC 50 60 Hz DEFINED WARM START 222 EB DF1 PLC 23242 2 x 42W PLC 092 79 0 720 42x264x34 0 250 25 AMBIENT TEMPERATURE ta 10 50 C CREST FACTOR CF lt 1 7 MAX CASE TEMPERATURE tc 70 C TOTAL HARMONIC DISTORTION THD THD lt 10 Measured under 140 Y mains ENERGY EFFICIENCY INDEX A2 PROTECTION CLASS IP 20 BALLAST LUMEN FACTOR BLF BLF gt 85 INSULATION CLASS OPERATING FREQUENCY 45 55 kHz WIRING DIAGRAM TECHNICAL DRAWING PRODUCTLIST LIST B 5esA PRODUCT FLUORESCENT POWER FACTOR RATED MAINS CURRENT DIMENSIONS WEIGHT Yin CODE LAMP POWER W A mm Electronic Ballast EB DF1 T8 11518 1 x 15W T8 0 98 15 0 135 42x264x34 0 205 25 EB DF1 T8 11518 1 x 18W T8 0 98 15 0 140 42x264x34 0 205 25 EB DF1 T8 13036 1 x 30W T8 0 99 32 0 295 42x264x34 0 205 25 EB DF1 T8 13036 1 x 36W T8 0 99 33 0 300 42x264x34 0 205 25 EB DF1 T8 158 1 x 58W T8 0 99 55 0 495 42x264x34 0 215 25 EB DF1 T8 21518 2x15W T8 0 97 30 0 140 42 264 34 0 250 25 ad e Lm EB DF1 T8 21518 2 x 18W T8 0 97 32 0 150 42x264x34 0 250 25 EB DF1 T8 23036 2 x 30W T8 0 99 50 0 270 42x264x34 0 250 25 EB DF1 T8 23036 2 x 36W T8 0 99 y 0 280 42 264 34 0 250 25 Bes A reserves the right to change the
21. 0 98 46 0 205 42x264x34 0 245 25 Inaccordance with 61347 1 EN 61347 2 3 60929 EB DF PLL 236 2 x 36W PLL 0 99 71 0 325 42x264x34 0 250 25 EB DF PLL 255 2x 55W PLL 0 99 92 0 415 42x264x34 0 250 25 EB DF PLC 113 1 x 13W PLC 0 94 20 0 095 42x264x34 0 205 25 EB DF PLC 118 1x18W PLC 0 95 22 0 105 42x264x34 0 205 25 EB DF PLC 126 1 x 26W PLC 0 97 28 0 130 42x264x34 0 205 25 TECHNICAL DATA EB DF PLC 13242 1x32W PLC 0 97 30 0 140 42x264x34 0 205 25 EB DF PLC 13242 1 x 42W PLC 0 98 41 0 190 42x264x34 0 205 25 SUPPLY VOLTAGE 230 VAC 50 60 Hz DEFINED WARM START es EB DF PLC 213 2x 13W PLC 0 98 40 0 185 42x264x34 0 245 25 AMBIENT TEMPERATURE 10 C 50 C CREST FACTOR lt 1 7 EB DF PLC 218 2x 18W PLC 0 98 43 0 195 42x264x34 0 245 25 MAX CASE TEMPERATURE tc USC TOTAL HARMONIC DISTORTION THD THD lt 10 EB DF PLC 226 2 x 26W PLC 0 99 54 0 250 42x264x34 0 245 25 ENERGY EFFICIENCY INDEX EEl 42 PROTECTION CLASS 20 EB DF PLC 23242 2 x 32W PLC 0 99 59 0 270 42x264x34 0 250 25 BALLAST LUMEN FACTOR BLF gt 85 INSULATION CLASS Il EB DF PLC 23242 2x42W PLC 023 75 0 340 42x264x34 0 250 25 OPERATING FREQUENCY 45 55 kHz Measured under 230 V mains PRODUCTLIST LIST WIRING DIAGRAM TECHNICAL DRAWING PRODUCT FLUORESCENT POWER FACTOR RATED MAINSCURRENT A DIMENSIONS WEIGHT CODE LAMP POWER W mm kg CARTON hi BOX z bes A EB DF T8 11518 1 x 15W T8 0 91 15 0 075 42x264x34 0 205 25 Electr
22. 14 x 0 35 W LED Double sided Lapin Surface Mounted Hook Hanger BYAL XL07 LED A Non Maintained 14 x 0 35 W LED Single sided Lipsos Wall Mounted BYAL XL07 LED S 1 3h Maintained 14 x 0 35 W LED Single sided Lipsos Wall Mounted Maintained Lights on mains and stays alight in case of the mains failure Non Maintained Lights in case of the mains failure MAINS DATA DATA PRODUCT RATED POWER MAINS CURRENT DIMENSIONS WEIGHT hell CODE A mm kg BYAL XLO6 LED A 1H E 0 010 630x43x430 2 215 1 BYAL XL06 LED A 3H 2 2 0 015 630x43x430 2 370 1 BYAL XLO6 LED S 1H 5 7 0 040 630x43x430 2 245 1 BYAL XL06 LED S 3H 6 2 0 045 630x43x430 2 400 1 BYAL XLO7 LED A 1H 1 7 0 010 630x43x430 2 215 1 BYAL XL07 LED A 3H 2 2 0 015 630x43x430 2 370 1 BYAL XLO7 LED S 1H 5 7 0 040 630x43x430 2 245 1 BYAL XL07 LED S 3H 6 2 0 045 630x43x430 2 400 1 Measured under 230 V mains TECHNICAL DRAWING WIRING DIAGRAM Unswitched Line Switched Line Neutral 630 Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice PRODUCT LIST LIST EMERGENCY EXIT LUMINARY LED PRODUCT RATED OPERATING LIGHT ROUTING TYPE CODE DURATION MODE SOURCE MODE OF MOUNTING MERCAN LED BYALO4 BYALO4 A LED CY 1 3h Non Maintained 7 X 0 35 W LED Double sided Surface Mounted Plastic Hanger BYALO4 A LED CY MT 1 3h Non Maintained 7
23. 1H 1h 1x36 W 4 pin PLL 0 70 ECOM PLL 136 3H 3h 1x36 W 4 pin PLL 0 70 ECOM PLL 155 1H 1h 1x55 W 4 pin PLL 0 70 ECOM PLL 155 3H 3h 1x55 W 4 pin PLL 0 70 Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice BATTERY AND MAINS DATA AND MAINS DATA QTY in EMERGENCY LIGHTING UNIT G RAT E D _ F L U 0 R ES C E N T LA M p PRODUCT BATTERY RATED MAINS CASE DIMENSIONS WEIGHT CARTON CODE CAPACITY POWER W CURRENT mm kg BOX ECOM2 PLL ECOM2 PLL 211 1H 6V 1800 mAh 26 0 175 42 264 34 0 327 30 ECOM2 PLL 211 3H 6V 4000 mAh 27 0 180 42x264x34 0 329 30 ECOM2 PLL 218 1H 6V 1800 mAh 26 0 175 42 264 34 0 327 30 o u ECOM2 PLL 218 3H 6 V 4000 mAh 27 0 180 42x264x34 0 329 30 Integrated electronic ballast and emergency lighting unit in the same PCB ECOM2 PLL 224 1H 6V 1800 mAh 41 0 265 EY 0 328 30 NIB Histo Gestion ECOM2 PLL 224 3H 6 V 4000 mAh 42 0 270 42 264 34 0 334 30 Low rating current ECOM2 PLL 236 1H 6V 1800 mAh 56 0 360 42 264 34 0 327 30 Silent vibration free lighting ECOM2 PLL 236 3H 6 V 4000 mAh 57 0 365 42 264 34 0 330 30 Easy assembly of luminary due to integrated design Emergency lighting function by interruption of the unswitched phase 1 3h duration Emergency lighting function in case of low voltage Compatible with 4 pin fluorescent lamps Prolonging the life of the lamp with warm start Short circu
24. 1H fos 0 034 335x63x220 1 080 1 BYAL04 S LED CY 3H 7 6 0 038 335x63x220 1 250 1 BYALO4 S LED CY MT 1H ies 0 034 25 276 1 160 1 Please refer to Pictogram Table in Emergency Exit Luminaries Overview section of the catalogue for alternatives BYAL04 S LED CY MT 3H 7 0 0 038 335 63 220 1 330 I BYALO4 A LED TY 1H 2 0 0 018 335x639x220 165 1 AA OSRAM BYALO4 A LED TY 3H 23 0 022 335 63 220 1 335 1 ROHS LED BYALO4 A LED TY MT 1H 2 0 0 018 227202278 jP225 1 BYALO4 A LED TY MT 3H 22 0 022 335x63x220 1 415 1 BYALO4 S LED TY 1H 7 3 0 034 335x63x220 1 215 1 50 60 Hz ABS 9976 2 42 BYALO4 S LED TY 3H 7 6 0 038 335 63 220 1 385 1 BYALOA S LED TY MT 1H 3 0 034 335x63x220 17225 1 In accordance with EN 60598 1 EN 60598 2 22 standards BYALOA S LED TY MT 3H 7 6 0 038 335x63x220 1 365 1 Measured under 230 V mains TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz SIGN DIMENSIONS 130 x 335 mm AMBIENT TEMPERATURE 10 C 40 C VIEWING DISTANCE 26 m WIRING DIAGRAM cd dl RATED DURATION 1 3h PROTECTION CLASS IP 20 BATTERY CHARGING TIME 24 48h INSULATION CLASS BATTERY TYPE 3 6 V NiCd we indie ame witched Line Neutral CONTROL PANEL PANEL CHARGE Charge Status Display LED Indicates charging process of the battery WI TEST Test Button Enables testing the product without mains cuts Ml FULL Battery Status Display LED Indicates the occupancy level of the battery
25. 4 5 0 70 Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice EMERGENCY LIGHTING UNIT BATTERY AND MAINS DATA S RAT D _ L U O R ES C LA M PRODUCT BATTERY RATED MAINS CASE DIMENSIONS WEIGHT PALIN CODE CAPACITY POWER W CURRENT A mm kg ECOM2 T5 gt ECOM2 T5 21314 1H 6 V 1800 mAh 30 0 190 42 264 34 0 325 20 ECOM2 T5 21314 3H 6 V 4000 mAh 31 0 195 42x264X34 0 329 20 ECOM2 T5 221 1H 6 V 1800 mAh 57 0 380 A2x264x34 0 325 30 Integrated electronic ballast and emergency lighting unit in the same PCB en 25 e m x pe nema ance Ope en ECOM2 T5 224 3H 6 V 4000 mAh 54 0 330 42x264x34 0 329 30 2 5 228 1 7 2 V 2200 mAh 62 0 405 42x264x34 0 327 30 pa SE ELO IES ECOM2 T5 228 3H 7 2 V 6000 mAh 63 0 410 42x264X34 0 330 20 2 temps ECOM2 T5 235 1H 7 2 V 2200 mAh 54 0 345 42x264x34 0 327 30 Easy assembly of luminary due to integrated design ECOM2 T5 235 3H 7 2 V 6000 mAh 55 0 350 42x264x34 0 330 30 Emergency lighting function by interruption of the unswitched phase ECOM2 T5 239 1H 6 V 1800 mAh 61 0 410 DERE 0 325 30 1 3 h duration ECOM2 T5 239 3H V 5000 mAh 6 0 415 42 264 34 0 329 20 Emergency lighting function in case of low voltage Compatible with 4 pin fluorescent lamps Prolonging the life of the lamp with warm start Short circuit open
26. 4 8V 9000 mAh D 35 4 35 248 35 0 640 Please refer to Battery Details Table in Emergency Lighting Unit Overview section of the catalogue for further battery information WIRING DIAGRAM TECHNICAL DRAWING zr L Unswitched Line EMLUS 220 0 5 1 5 mm N eutra F 3 120 Li 3 Switched Line po 4 Neutral r as E 00600 60 62 69 9 In accordance with EN 61347 1 EN 61347 2 7 and EN 60929 TECHNICAL DATA AMBIENT TEMPERATURE 10 C 50 C MAX OUTPUT POWER oW RATED DURATION 1 3h PROTECTION CLASS IP 20 PRODUCTLIST S LIST PRODUCT BATTERY RATED MAINS CASE DIMENSIONS WEIGHT 42 CODE CAPACITY POWER W CURRENT A mm BOX 4 8 V 2200 mAh 1 h 4 8 V 5000 mAh 3 h EMLUS 220 5W 4 1 0 020 43x185x34 0 225 30 Measured with 3 h circuits under 230 mains Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice EMERGENCY LIGHTING UNIT INTEGRATED LED PRODUCT BATTERY RATED MAINS CASE DIMENSIONS WEIGHT QTYin CODE CAPACITY POWER W CURRENT EC 0 M PW ECOM PW 2X1W 2H 9 6 V 900 mAh 2 h 0 039 42x264x34 0 275 30 ECOM PW 2X1W 4H 9 6 1600 mAh 4 h Did 0 041 42x264x34 0 275 30 ECOM PW 2X2W 1H 9 6V 900 mAh 1 h ihe 0 056 42x264x34 0 275 30 ECOM PW 2X2W 3H 9 6 1600 mAh 3 h 8 1 0 061 42x264x34 0 275 30
27. 42x264x34 0 255 25 Compatible with luminaries for protection class and protection class II EB DF1 T5 22835 2 x 28W T5 0 99 58 0 520 42 264 34 0 255 25 Ignite one lamp within multi lamp application EB DF1 T5 22835 2 35 5 0 29 69 0 625 42x264x34 0 255 25 Operate 110 VAC DC EB DF1 T5 239 2x39W T5 0 99 78 0 700 42x264x34 0 255 25 EB DF1 T5 41314 4x 13W T5 097 56 0 515 42x264x34 0 255 25 EB DF1 T5 41314 4x 14W T5 0 99 58 0 530 42x264x34 0 255 25 EB DF1 PLL 111 1x11W PLL 097 16 42x264x34 0 205 25 EB DF1 PLL 11824 1x 18W PLL 0 99 18 0 175 42x264x34 0 205 25 EB DF1 PLL 11824 1 x 24W PLL 0 99 28 0 205 42x264x34 0 205 25 EB DF1 PLL 136 1x36W PLL 0 99 37 0 330 42x264x34 0 205 25 EB DF1 PLL 155 1 x 55W PLL 0 55 0 505 42x264x34 0 210 25 CE i TH EB DF1 PLL 211 2x11W PLL 0 99 31 0 270 42 264 34 0 245 25 TL D 4P TLS 4P PL L 4P PL T C 4P EB DF1 PLL 218 2x 18W PLL 0 99 35 0 315 42 264 34 0 245 25 EB DF1 PLL 224 2 x 24W PLL 0 99 47 0 430 42x264x34 0 245 25 EB DF1 PLL 236 2 x 36W PLL 77 72 0 640 42x264x34 0 250 25 2 5 EB DF1 PLC 113 1x 13W PLC 0 99 20 0 190 42x264x34 0 205 20 EB DF1 PLC 118 1x18W PLC 0 99 22 0 200 42x264x34 0 205 25 In accordance with EN 61347 1 EN 61347 2 3 60729 EB DF1 PLC 126 1 x 26W PLC 0 99 28 0 255 42 264 34 0 205 25 EB DF1 PLC 13242 1 x 32W PLC 0 99 30 0 280 42x264x34 0 205 25 EB DF1 PLC 13242 1 x 42W PLC 0 99 42 0 385 42x264x34 0 205 25 EB DF1 PLC 213 2x 13W PLC 0 99 40 0 360 42x264x34
28. BYALO3Y CY MT 28 0 016 42 276 203 0 715 1 03 5 28 0 016 102x342x203 1 045 1 BYALO3Y TY SU 28 0 016 42x276x203 0 605 03 28 0 016 42x276x203 0 685 1 03 5 28 0 016 102x342x203 1 015 1 Measured under 230 V mains RECESSED MOUNTING HOLE SIZE WIRING DIAGRAM Unswitched Line Switched Line LO Neutral LO 335 TECHNICAL DRAWING TECHNICAL DRAWING RECESSED MOUNTED SURFACE MOUNTED 32 i 203 203 143 gt wt Bes reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice EMERGENCY EXIT LUMINARY LED PRODUCT LIST LAPIN LED 06 PRODUCT RATED OPERATING LIGHT ROUTING TYPE LIPSOS LED BYALO7 inn BYALO6 A LED on Non Maintained W CED Double sided Lapin Surface Mounted Plastic Hanger BYAL06 A LED MT 3h Non Maintained 7 x 0 35 W LED Double sided Lapin Surface Mounted Metal Hanger BYAL06 A LED SA ah Non Maintained 0 5 W PEED Double sided Lapin Recessed Mounted BYAL06 S LED 3h Maintained 7 x 0 35 W LED Double sided Lapin Surface Mounted Plastic Hanger BYAL06 S LED MT of Maintained ISS Double sided Lapin Surface Mounted Metal Hanger BYAL06 S LED SA 3h Maintained 7 0 35 W LED Double sided Lapin Recessed Mounted BYALO7 A LED 3h Non Maintained Jogo Single
29. Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice EMERGENCY LIGHTING UNIT L U 0 R E S C N T L A M p PRODUCT BATTERY RATED MAINS CASE DIMENSIONS WEIGHT FADE CODE CAPACITY POWER W CURRENT A mm kg E E MLUS P LC EMLUS PLC 10 32 1H 6V 1800 mAh eye 0 020 78x123x36 0 264 25 EMLUS PLC 10 18 3H 6 V 4000 mAh 4 3 0 022 78x123x36 0 268 25 EMLUS PLC 26 32 3H 6V 5000 mAh 5 2 0 027 78x123x36 0 282 25 EMLUS PLC 42 1H 7 2V 2200 mAh 4 2 0 021 78x123x36 0 265 25 EMLUS PLC 42 3H 7 2 V 6000 mAh 5 7 0 028 78x123x36 0 286 25 EMLUS PLC 210 18 1H 7 2V 2200 mAh 4 2 0 021 78x123x36 0 265 25 Compatible with electronic and magnetic ballast EMLUS PLC 210 18 3H 7 2 V 6000 mAh 5 7 0 028 78x123x36 0 286 25 Non maintained operation Emergency lighting function by interruption of the unswitched phase 1 3h duration Emergency lighting function in case of low voltage Single or double lamp preference in case of emergency Compatible with 4 pin fluorescent lamps Prolonging the lamp life with warm start Short circuit open circuit and overload protection High temperature Ni Cd battery cells Overcharge and deep discharge protection Polarity reversal protection for battery Charge status display with green LED Optional test switch Optional application of 110 V operating voltage Non flammable ABS case Simple connectable terminal block Measured under 230 V m
30. EB V110 PLL 11824 1x24W PLL 0 68 13 0 175 43x185x34 0 115 30 Compatible with emergency lighting units EB V110 PLL 136 1x 36W PLL 0 68 22 0 305 43x185x34 0 115 30 Non flammable ABS case EB V110 PLL 155 1x55W PLL 0 68 31 0 425 43x185x34 30 Non flammable CEM1 PCB material EB V110 PLC 11013 1x 13W PLC 0 68 6 0 090 43x185x34 0 115 30 Simple connectable terminal block EB V110 PLC 118 1x18W PLC 0 68 11 0 150 43x185x34 30 Operate 110 V AC DC EB V110 PLC 126 1x26W PLC 0 68 15 0 190 43x189x34 0 115 30 Measured under 110 V mains WIRING DIAGRAM TECHNICAL DRAWING nus Ir ooo Ba de TL D 4P TL5 4P PL L 4P PL T C 4P 110VAC VO Hz D gt 29 In accordance with EN 61347 1 EN 61347 2 3 TECHNICAL DATA SUPPLY VOLTAGE 110 VAC 50 60 Hz OPERATING FREQUENCY 30 50 kHz AMBIENT TEMPERATURE 10 50 C DEFINED WARM START lt 0 55 MAX CASE TEMPERATURE ONE PROTECTION CLASS IP 20 ENERGY EFFICIENCY INDEX INSULATION CLASS I BALLAST LUMEN FACTOR gt 5 60 Bes reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice PRODUCT LIST Con t LIST Con t 1 10V DIGITAL ELECTRONIC BALLAST PRODUCT FLUORESCENT POWER RATED MAINS CURRENT DIMENSIONS WEIGHT RN CODE LAMP FACTOR POWER W mm kg BOX EB DF1 EB DF1 T8 41518 4x 15W T8 0 29 64 0 570 42x264x34 04255 25 EB
31. EID 0 020 40 x 244 x 185 0 645 1 High temperature Ni Cd battery cells BYAL S08 CY MT 35 0 020 40 x 244 x 185 0 725 1 Overcharge and deep discharge protection BYAL S08 CY SA 35 0 020 102 31252185 7205 1 T t Plexigl ith int a en pong Measured under 230 V mains Side lighting Ceiling mounted ceiling recessed or wall mounted Optional application of 110 V operating voltage Optional metal hanger or hook RECESSED MOUNTING HOLE SIZE WIRING DIAGRAM 7 PB om tit PHI e i EN Unswitched Line Switched Line Neutral gt 309 Please refer to Pictogram Table in Emergency Exit Luminaries Overview section of the catalogue for alternatives 4443 R HS bsi oe 230 VAC VO Ey 2 Es EE Inaccordance with EN 60598 1 EN 60598 2 22 standards TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz SIGN DIMENSIONS 130x235 mm AMBIENT TEMPERATURE ta 10 40 C VIEWING DISTANCE 26 m TECHNICAL DRAWING TECHNICAL DRAWING RATED D TIME T I INSUDATON CURES i E SURFACE MOUNTED RECESSED MOUNTED BATTERY TYPE 3 6 V NiCd 244 40 aoc d CONTROL PANEL PANEL CHARGE Charge Status Display LED Indicates charging process of the battery TEST Test Button Enables testing the product without mains cuts FULL Battery Status Display LED Indicates the occupancy level of the battery 165
32. Hanger BYALO6 A MT Non Maintained 8 W T5 Fluorescent Double sided Surface Mounted Metal Hanger k 06 5 SIN Non Maintained 8 W T5 Fluorescent Double sided Lapin Recessed Mounted P EAN 06 5 iron Maintained 8 W T5 Fluorescent Double sided Lapinj Surface Mounted Plastic Hanger BYALO6 S MT MS Maintained 8 W T5 Fluorescent Double sided Lapin Surface Mounted Metal Hanger 06 5 5 1 3h Maintained 8 W T5 Fluorescent Double sided Lapin Recessed Mounted BYALO7 A ier Non Maintained 8 W T5 Fluorescent Single sided Lipsos Surface Mounted Plastic Hanger gt BYALO7 A MT 1 3h Non Maintained 8 W T5 Fluorescent Single sided Lipsos Surface Mounted Metal Hanger e BYALO7 A SA Non Maintained 8 W T5 Fluorescent Single sided Lipsos Recessed Mounted BYALO7 S 13h Maintained 8 W T5 Fluorescent Single sided Lipsos Surface Mounted Plastic Hanger BYALO7 S MT eile Maintained 8 W T5 Fluorescent Single sided Lipsos Surface Mounted Metal Hanger BYALO7 S SA 1 3h Maintained 8 W T5 Fluorescent Single sided Lipsos Recessed Mounted Maintained Lights on mains and stays alight in case of the mains failure Non Maintained Lights in case of the mains failure Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice EMERGENCY EXIT LUMINARY PRODUCT LIST LIST E L
33. It is accepted that the daylight has a CRI of 100 length with a fluorescent lamp that has an equivalent power and in a way that can emit the same level of light flux Compared to Luminous Efficiency Lm W fluorescent lamps they have a longer life and they are more energy efficient Luminous efficiency is also known as the efficiency factor The luminous efficiency of the light source is the ratio of the total light flux emitted from the source to the power of the source Luminous efficiency e In incandescent lamps 12 15 lm W e In halogen lamps 18 22 lm W e In compact fluorescent lamps 60 Im W e In fluorescent lamps 55 104 Im W e In LEDs it differs according to the color f a 1 H i n amp IM 2 gt pu a ndi 2 gt gt E MAINSDATA DATA C STA N T C U R R E N T L E D D R IV E R PRODUCT POWER THD RATED POWER cR DIMENSIONS WEIGHT QTY in CODE FACTOR W mm kg CARTON LDRV 10 BOX LDRV 10 700 0 95 23 12 0 060 43 185 34 0 105 30 Measured at full load under 230 V mains WIRING DIAGRAM TECHNICAL DRAWING a 137l E Bas A Constant Current Phase LED Driver Neutral wus 8 SO In accordance with EN 61347 1 EN 61347 2 13 and EN 62384 TECHNICAL DATA AMBIENT TEMPERATURE 10 50 C TOTAL HARMONIC DISTORTION THD
34. Lamp EMLUS PLC 210 18 1H Th 2x10 13 18 W 4 pin PLC Double Lamp EMLUS PLC 210 18 3H 3h 2x10 13 18 W 4 pin PLC Double Lamp Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice EMERGENCY LIGHTING UNIT PRODUCT LIST Con t INTEGRATED FLUORESCENT LAMP CODE DURATION POWER TYPE POWER FACTOR oes ECOM T5 5 149 1 1h 1x49 W 4 pin T5 0 70 ECOM T5 149 3H 3h 1x49 W 4 5 0 70 5 154 1 1h 1x54 W 4 pin 5 0 70 5 154 3 3h 1x54 W 4 pin 5 0 70 5 180 1 1h 1x80 W 4 pin 5 0 70 Integrated electronic ballast and emergency lighting unit in the same PCB ECOM T5 180 3H 3h 1x80 W 4 5 0 70 Non maintained operation Low rating current Silent and vibration free lighting Easy assembly of luminary due to integrated design BATTERY AND MAINS DATA Emergency lighting function by interruption of the unswitched phase QTY in or OR PRODUCT BATTERY RATED MAINS CASE DIMENSIONS WEIGHT CARTON n v 1 CODE CAPACITY POWER CURRENT mm BOX Emergency lighting function in case of low voltage Compatible with 4 pin fluorescent lamps ECOM T5 10608 1H 3 6 V 1000 mAh 10 0 070 x34 0 245 30 Prolonging the life of the lamp with warm start ECOM T5 10608 3H 3 6 V 3000 mAh 11 0 075 39x221x34 0 245 30 Short circuit open circuit and overload protection ECOM T5 11314 1H V 1800 mAh
35. POWER W CURRENT A mm kg lh TETRA AA1207 AA1Y ee 0 023 0 141 106x279x273 4 820 1 AA1214 AA1Y 3 8 28 6 0 028 0 148 135x320x375 7 630 1 AA1507 AA1Y 0 023 0 141 106x279x273 4 820 1 AA1514 AA1Y 4 0 30 6 0 030 0 145 135x320x375 8 570 1 AA2207 AA2Y 0 023 0 141 135x320x375 5 850 1 AA2214 AA2Y 3 8 28 6 0 028 0 148 135x320x375 7 950 1 Indoor and outdoor use AA2228 AA2Y 5 4 28 6 0 033 0 149 135x320x375 12 150 Portable AA2514 AA2Y 3 8 28 6 0 028 0 148 135x320x375 8 420 1 180 adjustable halogen headlamp AA2528 AA2Y 5 6 30 6 0 035 0 155 128x394x450 13 740 1 Moisture proof Emergency lighting function by interruption of the unswitched phase Emergency lighting function in case of low voltage 1 6 h duration in case of emergency Battery capacity status display with green LED Lamp error status display with green LED Test switch Maintenance free sealed lead acid battery Overcharge and deep discharge protection Charging circuit with constant voltage and current protect Wall mounted Unswitched Line Optional on off button Switched Line Optional application of 110 V operating voltage Neutral Lay Measured under 230 V mains Minimum values are measured with discharged batteries and maximum values are measured with full charged batteries WIRING DIAGRAM TECHNICAL DRAWING lt gt 2 230 VAC lili 50 60 Hz Lead Acid 5098 2 22 In accordance with E
36. T8 Single Lamp bn ud Mass EMLUS T8 215 18 1H 1 h 2x15 18 W 4 pin T8 Double Lamp EMLUS T8 215 18 3H 3h 2x15 18 W 4 T8 Double Lamp Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice EMERGENCY LIGHTING UNIT F L U 0 R ES C E N LA M P PRODUCT BATTERY RATED MAINS CASE DIMENSIONS WEIGHT QTYin CODE CAPACITY POWER W CURRENT A mm kg a EM LUS PLL EMLUS PLL 11 55 1H 6V 1800 mAh 38 0 020 43x185x34 0 238 30 EMLUS PLL 11 36 3H 6V 4000 mAh 4 3 0 022 43x185x34 0 242 30 EMLUS PLL 55 3H 6V 5000 mAh Sp 0 027 43x185x34 0 257 30 EMLUS PLL 211 24 1H 7 2V 2200 mAh 4 2 0 021 43x185x34 0 236 30 EMLUS PLL 211 24 3H 7 2 V 6000 mAh S 0 028 43x185x34 0 255 30 Compatible with electronic and magnetic ballast Measured under 230 V mains Non maintained operation Emergency lighting function by interruption of the unswitched phase 1 3 h duration Emergency lighting function in case of low voltage Single or double lamp preference case of emergenc Mm with 4 pin fluorescent Eae EMERGENCY LUMEN FACTOR BLF Prolonging the lamp life with warm start PRODUCT 11W PLL 18W PLL 24W PLL 36W PLL 55W PLL Short circuit open circuit and overload protection High temperature Ni Cd battery cells EMLUS PLL 30 17 16 13 11 Overcharge and deep discharge protection Polarity reversal protection for battery Charge status display with green LED Optional te
37. U O R ES C E N LA M PRODUCT RATED OPERATING LIGHT ROUTING TYPE CODE DURATION MODE SOURCE MODE OF MOUNTING LAPIN XL BYAL XL06 LIPSOS XL BYAL XL07 BYAL XLO6 A 1 3h Maintained 13W T5 Fluorescent Double sided Lapin Surface Mounted Hook Hanger BYAL XL06 S 1 3h Maintained 13 W T5 Fluorescent Double sided Lapin Surface Mounted Hook Hanger BYAL XLO7 A Non Maintained 13 W 5 Fluorescent Single sided Lipsos Wall Mounted 07 5 1 3 Maintained 13 W 5 Fluorescent Single sided Lipsos Wall Mounted Maintained Lights on mains and stays alight in case of the mains failure Non Maintained Lights in case of the mains failure Single or double sided Anodized aluminum case Non flammable ABS edge and hanger 13 W T5 Fluorescent Tube Charge and battery capacity status display with green LEDs MAINS DATA DATA Test switch PRODUCT RATED POWER MAINS CURRENT DIMENSIONS WEIGHT ean High temperature Ni Cd battery cells CODE w A mm kg BOX Overcharge and deep discharge protection Whe sane BYAL XL06 A 1H zu 0 015 630x43x430 2120 1 Back Lighting BYAL XL06 A 3H 39 0 018 630x43x430 2 349 1 Ceiling mounted or wall mounted BYAL XL06 S 1H a Optional application of 110 V operating voltage BYAL XL06 S 3H ls d 2 Optional metal hanger or hook BYAL XL07 A 1H 20 Sun 2000 BYAL XL07 A 3H 3 0 0 018 630x43x430 2 340 1 BYAL XL07 S 1H 0 100 630 4
38. X 0 35 W LED Double sided Surface Mounted Metal Hanger BYAL04 S LED CY nah Maintained 7X 0 35 W LED Double sided Surface Mounted Plastic Hanger BYALO4 S LED CY MT 1 3h Maintained 7 X 0 35 W LED Double sided Surface Mounted Metal Hanger BYALOA A LED TY Mh Non Maintained 7 0 35 W LED Single sided Surface Mounted Plastic Hanger BYALO4 A LED TY MT 1 35 Non Maintained 7X0 35 W LED Single sided Surface Mounted Metal Hanger BYALO4 S LED TY 1 3h Maintained 7 X 0 35 W LED Single sided Surface Mounted Plastic Hanger BYALO4 S LED TY MT 1 3h Maintained 7 X 0 35 W LED Single sided Surface Mounted Metal Hanger Single or double sided Anodized aluminum case Maintained Lights on mains and stays alight in case of the mains failure Non flammable ABS side cover and hanger Non Maintained Lights in case of the mains failure SMD LED application Charge and battery capacity status display with green LEDs Test switch High temperature Ni Cd battery cells MAINS DATA NE DATA Overcharge and deep discharge protection White acrylic plate PRODUCT RATED POWER MAINS CURRENT DIMENSIONS WEIGHT eU Back lighting CODE w A En x Boy x Y k kg BOX Ceiling mounted or wall mounted Optional UE of 110 V operating voltage BYALO4 A LED CY 1H aL aes Us Optional metal hanger or hook BYALOA A LED CY 3H 23 0 022 335 63 220 1 200 1 BYALOA A LED CY MT 1H 20 0 018 335x63x220 1 110 1 BYALOA A LED CY MT 3H 2 0 022 335x63x220 1 280 1 BYAL04 S LED CY
39. equivalent of LED fluorescents with LED sticks the amount given in must be used Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice LED sticks must be driven by constant current LED drivers BALLAST amp ELECTRONIC TRANSFORMER oes BALAST Ballast is the device connected between the lamp and the main power for limiting or regulating the current of the discharge lamps by means of Inductance capacity or resistance Ballasts can either be made up of any one of the resistance inductance or capacity elements or they may have a structure comprised of several of these elements and most of the auxiliary elements including transformers cold igniters and interference reducers A good ballast circuit must have the following characteristics e t must not lead to a high power loss e t must ensure that the lamp illuminates at full power e t must work without noise e t must not cause radio interference e must not distort the current wave e t must a structure that can ignite the lamp easily e t must be durable e t must not overheat Ballast loss 15 one of the important factors that affect the efficiency of the system The ballasts used fluorescent lamps are subjected to an energy classification The energy classification of the ballasts
40. level of the battery a 139 5 220 Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice EMERGENCY EXIT LUMINARY PRODUCT LIST FLUORESCENT LAMP CODE DURATION MoDE SOURCE MODE OF MOUNTING SOMON BYPLOT ByploAXW Non Maintained 8W T5 Fluorescent Sngle sided wallMounted BYPLO1 S 1X08W 1 3h Maintained 8 W T5 Fluorescent ingle side Wall Mounted Maintained Lights on mains and stays alight in case of the mains failure Non Maintained Lights in case of the mains failure oes MAINS DATA PRODUCT RATED POWER MAINS CURRENT DIMENSIONS WEIGHT QTY in CODE W A mm BOX BYPLO1 A 1X08W 3H 2 0 0 015 104x340x89 0 770 1 BYPLO1 S 1X08W 3H 11 0 075 104x340x89 0 840 1 Measured under 230 V mains Please refer to Pictogram Table in Emergency Exit Luminaries Overview section of the catalogue for alternatives WIRING DIAGRAM TECHNICAL DRAWING Switched Line Neutral 230 6 E Es 8 E 55 In accordance with EN 60598 1 EN 60598 2 22 standards TECHNICAL DATA 340 CANT AMBIENT TEMPERATURE 10 40 C VIEWING DISTANCE 20m BATTERY CHARGING TIME 24 48h INSULATION CLASS II CONTROL PANEL PANEL CHARGE Charge Status Display LED Indicates charging process of the battery W TEST Test Button Enables testing t
41. points larger than 60m are classified as open areas the interruption of normal lighting This lighting type is not included in emergency escape scenarios The magnitude of illumination above the floor level at open areas must be at least 0 5 lux The edges and the area surrounding mu the edges within 0 5 meter are not included in this scope The ratio of the magnitude of illumination between the most and the Emergency Escape Lighting least illuminated points in open areas must not be more than 40 1 Emergency escape lighting is the emergency lighting that provides the necessary lighting for the safety of the people who are evacuating a building or an area in the case of an emergency or who are trying to finalize a potentially hazardous action before evacuation There are 3 types of emergency escape lighting A Escape Route Lighting uU M Minimum lighting level Emin 0 0 lx Escape route lighting is the emergency lighting type that assists in the safe evacuation of the people from the building by illuminating the escape routes in the case of an emergency Minimum maximum lighting level ratio B Open Area Lighting Esos ss AD s TAX Open area lighting is the lighting type envisaged for areas larger than 60m or for gathering points and it provides access to the predetermined escape routes in the case of an emergency It is also known as anti panic lighting Color rendering index CRI 2 40 C Highly Risky Task Area Lighting High
42. sided Lipsos Surface Mounted Plastic Hanger BYALO7 A LED MT 3h Non Maintained 7 x 0 35 W LED Single sided Lipsos Surface Mounted Metal Hanger BYALO7 A LED SA 3h Non Maintained Single sided Lipsos Recessed Mounted Verito eds ane decia eoe BYALO7 S LED 3h Maintained 7 x 0 35 W LED Single sided Lipsos Surface Mounted Plastic Hanger SIMIE LED eros tenian BYALO7 S LED MT 3h Maintained 1x035 WLED Single sided Lipsos Surface Mounted Metal Hanger hene stu Eel stacey gras LL zie BYAL07 S LED SA 3h Maintained 7x0 35WLED Single sided Lipsos Recessed Mounted Test switch Maintained Lights on mains and stays alight in case of the mains failure High temperature Ni Cd battery cells Non Maintained Lights in case of the mains failure Overcharge and deep discharge protection MAINS DATA NS DATA White acrylic plate QTY in I I sers tss PRODUCT BALD OWEN MURS CURRENT BIN ne ar Ceiling mounted ceiling recessed or wall mounted BOX Optional application of 110 V operating voltage BYALO6 A LED 128 0 010 365 43 168 0 770 1 Optional metal hanger or hook BYALO6 A LED MT 1 5 0 010 365x43x168 0 850 1 BYALO6 A LED SA 15 0 010 425x43x186 0 900 1 BYALO6 S LED 5 0 0 030 365x43x168 0 770 1 BYALO6 S LED MT 5 0 0 030 365x43x 168 0 850 1 BYAL06 S LED SA 5 0 0 030 425x43x186 0 900 1 BYALO7 A LED 0 010 365x43x168 0 915 1 Please refer to Pictogram Table in Emergency Ex
43. sign pictogram must VE Ge u be at least 10 cm if it is illuminated from within and at least 20 cm if it is illuminated from outside 4 7 PE GEH LIGHTING DURATION OF THE EMERGENCY EXIT LUMINARIES PET EE Ext A8 B8 D8 E8 Emergency lighting must be provided for at least 60 minutes in the case of an Interruption the normal lighting In the buildings with a occupants load of 200 or more emergency lighting must be provided for at least 120 minutes For the sings illuminated from within it has For the sings illuminated from outside it to be 200 times of the height of the sign has to be 100 times of the height of the sign E M F RG E N CY EXIT LU M LE D PRODUCT RATED OPERATING LIGHT ROUTING TYPE CODE DURATION MODE SOURCE MODE OF MOUNTING TU NA 5 BYALOS BYAL S08 CY SU oh Maintained 6 x 0 1W LED Double sided Surface Mounted Plastic Hanger BYAL S08 CY MT 3h Maintained 6 x 0 1W LED Double sided Surface Mounted Metal Hanger BYAL S08 CY SA 3h Maintained 6 x 0 1W LED Double sided Recessed Mounted Maintained Lights on mains and stays alight in case of the mains failure Double Sided Anodized aluminum case MAINS DATA NS DATA Non flammable ABS side cover and hanger SMD LED application PRODUCT RATED POWER MAINS CURRENT DIMENSIONS WEIGHT QTY in CODE W A mm kg nn Charge and battery capacity status display with green LEDs BOX Test switch BYAL S08 CY SU
44. 0 RM 0 00 Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice EMERGENCY LIGHTING LUMINARY L E D PRODUCT RATED MAINS DIMENSIONS WEIGHT QTY in CODE POWER W CURRENT Aj inim kg CARTON TETRAPOWER pon aa msm oo 1 AA210 PW3H 3 3 27 9 0 023 D 141 106x279x273 4 740 1 Measured under 230 V mains WIRING DIAGRAM TECHNICAL DRAWING Unswitched Line Switched Line R 63 Neutral Height lt R Length s Length Width RAM O 2551 OsRAM 230 ili 50 60 Hz Lead Acid 60598 2 22 In accordance with EN 60598 1 EN 60598 22 TECHNICAL DATA AMBIENT TEMPERATURE 10 40 C CASE MATERIAL PVC BATTERY CHARGING TIME 24 48h INSULATION CLASS II PRODUCTLIST LIST PRODUCT RATED OPERATING LIGHT LIGHT INTENSITY on TYPE of BATTERY CODE DURATION MODE SOURCE ENERGY EMERGENCY MOUNTING 4 AA210 PW 3 6h Non Maintained 2x10 W LED 1500 lm Surface Mounted 24 48h Non Maintained Lights in case of the mains failure Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice EMERGENCY LIGHTING LUMINARY 2 SNTE FLUORESCENT LAMP PRODUCT A A DIMENSIONS weht BOX SOMON BYP L01 BYPLO1 A 1X08 W 1H 1 4 0 013 104x340x89 0
45. 1 EN 60598 22 th 9 35 General Emergency 1 LIGHT DISTRIBUTION CURVE TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz COLOR TEMPERATURE 4000 K 6500 K 1 AMBIENT TEMPERATURE 10 C 40 C COLOR RENDERING INDEX CRI 80 Nh AN RATED DURATION 1 3h OPTICAL EFFICACY 97 115 Im W WY 46 BATTERY CHARGING TIME 24 48h PROTECTION CLASS 20 N DA DIFFUSER Opal Plexiglas INSULATION CLASS ee E 180 0 00 I y 2700 900 E N 000 10200 000 ar Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice EMERGENCY LIGHTING LUMINARY LED SOMON LED BYPL01 LED Indoor and outdoor use Polyamide 6 case Polycarbonate glass Protection class IP44 SMD LED application High energy saving 50 Long life time 50 000 hours Emergency lighting function by interruption of the unswitched phase Emergency lighting function in case of low voltage 1 3h duration in case of emergency Battery charge and capacity status display with green LED Test switch High temperature Ni Cd battery cells Overcharge and deep discharge protection Surface and recessed mounted Optional application of 110 V operating voltage CE O lt OSRAM 230 6 E E Ge Es E In accordance with 60598 1 EN 60598 22
46. 10 16 52 W 90 Measured at full load under 230 V mains Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice 147 PANEL APPLICATIONS APPLICATIONS 1 Des 5 LED PANEL LPN aja bes A 5es LED Panel LED Panel E 30x60 Luminary Application Compatible with linear and panel lights Self cooling no additional heat sink required na Luminous flux range between 850 2200 lm bes A bes A Color temperatures 4000 K and 6500 K LED Panel LED Panel Long LED life time 50 000 h High luminous efficacy 115 Im W High color rendering index CRI gt 80 60x60 Luminary Application 30x120 Luminary Application Short homogeneity distance 5 5 cm Symmetrical design for multi panel applications Easy installation Suitable for all luminaries Non flammable FR4 PCB Simple connectable terminal block LED Panel LED Panel LED Panel LED Panel LED Panel LED Panel PANEL HOLE SIZES HOLE SIZES B mm a mm b mm c mm d mm EPN 2509E5 250 250 20 2 202 43 LPN 2513E5 250 250 25 2 26 2 57 4 43 LPN 2520E5 250 250 62 4 48 2523 5 250 250 29 22 6 72 23 CE aXus Oo OSRAM LPN 2709E5 270 270 33 8 33 8 67 6 52 LED mM LPN 2713E5 270 270 33 8 33 8 67 6 92 LPN 2720E5 270 270 38 8 38 8 72 6 57 LPN 2723E5 270 270 42 6 30 2 82 32 PCB In accordance with 62031 6
47. 12 0 073 42x264x34 0 301 30 Polarity reversal protection for battery ECOM PW 6X1W 2H 19 2 V 900 mAh 2 h TOES 0 075 42x264x34 0 297 30 Charge status display with green LED ECOM PW 6X1W 4H 19 2 V 1600 mAh 4 h 129 0 080 42x264x34 0 297 30 Optional test switch ECOM PW 7X1W 2H 24V 900 mAh 2 h 12 0 0 080 42x264x34 0 301 30 ECOM PW 7X1W 4H 24V 1600 mAh 4 h 125 0 095 42x264x34 0 301 30 Optional application of 110 V operating voltage Non flammable ABS case i LED drive current is 350 for X1W 700 mA for X2W 1050 mA for x3W Simple connectable terminal block Measured under 230 V mains BATTERY DATA RY DATA optional O gt VOLTAGE CAPACITY CELL TYPE CELL SIZE QTY OF CELLS DIMENSIONS WEIGHT mm mm kg 3 6 V 900 mAh 14 5 3 29x50x29 0 084 3 6 V 1600 mAh SC 23 3 23x135x23 0 135 d ith EN 61347 1 EN 61347 2 7 and EN 61347 2 13 Mos een 9 6 V 1600 mAh SC 23 8 46x180x23 0 360 PY 900 mAh AA 14 5 12 50x87x29 0 336 144V 1600 mAh SC 23 12 46x135x46 0 540 19 2 V 900 mAh AA 14 5 16 50x116x29 0 448 TECHNICAL DATA 19 2 V 1600 mAh SC 23 16 46 180 46 0 720 24V 900 mAh AA 14 5 20 50x145x29 0 560 SUPPLY VOLTAGE 230 VAC 50 60 Hz EMERGENCY LUMEN FACTOR 85 _ ze _ 2 0 900 AMBIENT TEMPERATURE ta 10 50 C MAX OUTPUT POWER 10 W _ CASING TEMPERATURE tc 70 C OUTPUT VOLTAGE
48. 2 accordance with 60598 1 60598 22 RN a a inr A _ _ J J TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz LIGHT SOURCE 8 W T5 Fluorescent AMBIENT TEMPERATURE 10 C 40 C DIFFUSER Polycarbonate Glass RATED DURATION 55 IP 44 BATTERY CHARGING TIME 24 48h INSULATION CLASS 1 TER VNTVERZ TECHNICAL DRAWING TECHNICAL DRAWING SURFACE MOUNTED RECESSED MOUNTED PRODUCT LIST PRODUCT RATED OPERATING LIGHT LIGHT INTENSITY on TYPE of BATTERY s CODE DURATION MODE SOURCE ENERGY EMERGENCY MOUNTING en BYPLO1 A 1X08 W UST Non Maintained 1x8 W T5 Fluorescent 55 lm Surface Mounted 24 48 h BYPLO1 A 2X08 W 1 3h Non Maintained 2x8 W T5 Fluorescent 140 lm Surface Mounted 24 48h BYPLO1 A 1X08 W SA Non Maintained 1x8 W Tb Fluorescent 55 lm Recessed 24 48h BYPLO1 A 2X08 W SA 17 3h Non Maintained 2x8 W T5 Fluorescent 140 lm Recessed 24 48h i BYPLO1 S 1X08 W Maintained 1x8 W T5 Fluorescent 220 linn 55 Im Surface Mounted 24 48h amp BYPLO1 S 2X08 W 1 3h Maintained 2x8 W 5 Fluorescent 380 Im 140 Im Surface Mounted 24 48h BYPLO1 S 1X08 W SA 1235 Maintained 1x8 W T5 Fluorescent 220m SE Im Recessed 24 48 h 01 5 2 08 W SA 1 3h Maintained 2x8 W T5 Fluorescent 380 lm 140 Im Recessed 24 48 h P de an Maintained Lights on mains and stays alight in case of the mains failure Non Maintained Lights in
49. 2 0 027 39x221x34 0 244 30 Emergency lighting function in case of low voltage EMLUS PW 6X1W 2H 19 2 V 900 mAh 2 h 4 0 0 023 0 238 30 Constant current output EMLUS PW 6X1W 4H 19 2 V 1600 mAh 4 h 4 8 0 026 39 221 34 0 238 30 Drive 1 9 1 to 9 serially connected LED pieces EMLUS PW 6X3W 1H 19 2 V 900 mAh 1 h 4 0 0 023 39x221x34 0 238 30 Short circuit open circuit and overload protection EMLUS PW 6X3W 2H 19 2 V 1600 mAh 2 h 4 8 0 026 3222184 0 238 30 High temperature Ni Cd battery cells EMLUS PW 7X1W 2H 24V 900 mAh 2 h 5 6 0 030 IZA O 0 238 30 Overcharge and deep discharge protection EMLUS PW 7X1W 4H 24V 1600 mAh 4 h 7 5 0 036 39X22 1x34 0 238 30 Polarity reversal protection for battery EMLUS PW 7X3W 1 H 24 V 900 1 h 50 0 030 39x221x34 0 238 30 Charge status display with green LED EMLUS PW 7X3W 2H 24 V 1600 mAh 2 h 75 0 036 39 221 34 0 238 30 Optional test switch EMLUS PW 8X1W 2H 28 8 900 mAh 2 h 4 5 0 024 39 221 34 0 248 30 Optional application of 110 V operating voltage EMLUS PW 8X1W 4H 28 8 V 1600 mAh 4 h 4 7 0 026 39x221x34 0 248 30 K oe EMLUS PW 8X3W 1H 28 8 V 900 mAh 1 h 4 5 0 024 39 221 34 0 248 30 EMLUS PW 8X3W 2H 28 8 V 1600 mAh 2 h 4 7 0 026 39x221x34 0 248 30 EM EMLUS PW 9X1W 2H 28 8 V 900 mAh 2 h 4 8 0 027 39x221x34 0 239 30 EMLUS PW 9X1W 4H 28 8 V 1600 mAh 4 h 6 3 0 032 39x221x34 0 242 30 EMLUS PW 9X3W 1H 28 8 V 900 mAh 1 h 4 8 0 027 39 221 34 0 239 30
50. 2 86 28 57 21 43 IECEE A 12 TUVRheinland e RYHS LED 230 VAC VO FR4 50 60 Hz ABS PCB In accordance with EN 61347 1 EN 61347 2 7 and EN 60929 Measured with 7 2 V battery under maximum operating voltage BATTERY DATA RY DATA VOLTAGE CAPACITY CELL TYPE CELL SIZE QTY OF CELLS DIMENSIONS WEIGHT mm mm kg TAN 900 mAh AA 145 14 9x286x14 9 0 168 TEC CAL DATA JM 1600 mAh SG 23 23x270x23 0 250 SUPPLY VOLTAGE 230 VAC 50 60 Hz OUTPUT CURRENT 100 300 mA a r AMBIENT TEMPERATURE 10 50 C OUTPUT VOLTAGE 1 60 VDC 79 V 5000 a D 35 4 ee 0950 CASING TEMPERATURE USE OPEN CIRCUIT VOLTAGE INDE GER RATED DURATION 1 3h PROTECTION CLASS IP 20 Please refer to Battery Details Table in Emergency Lighting Unit Overview section of the catalogue for further battery information BATTERY CHARGING TIME 24 48h INSULATION CLASS EMERGENCY LUMEN FACTOR BLF 10 85 WIRING DIAGRAM TECHNICAL DRAWING PRODUCTLIST LIST L PRODUCT OUTPUT LED MODULE OUTPUT LED CURRENT LED OUTPUT N Ht CODE CURRENT VOLTAGE RANGE TOLERANCE QUANTITY POWER EMLUS XLED150 01 21V 150 mA 1 21 VDC 5 3 02 W EMLUS XLED150 22 36V 150 mA 22 36 VDC 5 8 12 LED 5 10 W L Switched Line EMLUS XLED150 37 60V 150 100 mA 37 60 VDC 5 ea les 5 68 W Unswitched Line E EMLUS XLED300 01 12V 300 mA 1 12 VDC 5 1 4 LED 2 70 W N Neutral EM
51. 245 25 Compatible with emergency lighting units EB DF T5 21314 2 x 13W T5 0 98 41 D170 42x264x34 0 245 25 Non flammable ABS case EB DF T5 21314 2x 14W T5 0 98 2 0 200 42x264x34 0 245 25 Non flammable CEM1 PCB material EB DF T5 221 2x 21W T5 0 98 43 0 200 42x264x34 0 255 25 Simple connectable terminal block EB DF T5 224 2 x 24W T5 Apes 47 0 210 42x264x34 0 255 25 Compatible with luminaries for protection class and protection class ll EB DF T5 22835 2 x 28W T5 0 99 56 0 255 42 264 34 0 255 25 Ignite one lamp within multi lamp application EB DF T5 22835 2x39W T5 0 29 65 0 300 42 264 34 0 255 25 Operate 230 V AC DC EB DF T5 239 2x39W T5 0 99 81 0 360 42x264x34 0 255 25 EB DF T5 249 2x49W T5 0 99 102 0 450 42x264x34 0 255 25 EB DF T5 254 2 x D4W T5 0 99 97 0 440 42x264x34 0 255 25 EB DF T5 280 2 x 80W T5 0 99 120 0 550 42x264x34 0 255 25 G EB DF T5 41314 4 x 13W T5 0 99 55 0 250 42x264x34 0 255 25 EB DF T5 41314 4x 14W T5 079 57 0 260 42x264x34 0 255 25 EB DF PLL 111 1x 11W PLL 0 91 15 0 075 42x264x34 0 205 25 EB DF PLL 11824 1x 18W PLL 0 92 16 0 080 42x264x34 0 205 25 CE i EB DF PLL 11824 1x24W PLL 0 96 23 0 110 42 264 34 0 205 25 TL D 4P TL5 4P PL L 4P PL T C 4P EB DF PLL 136 1x36W PLL 0 98 7 0 170 42 264 34 0 205 25 EB DF PLL 155 1 x 55W PLL 0 99 54 0 250 42x264x34 0 210 25 EB DF PLL 211 2x 11W PLL 97 30 0 140 42x264x34 0 245 25 2 5 EB DF PLL 218 2x 18W PLL 0 98 37 0 165 42x264x34 0 245 25 EB DF PLL 224 2x 24W PLL
52. 2471 TECHNICAL DATA TECHNICAL DRAWING WIRING DIAGRAM SUPPLY VOLTAGE 12 4V 22V 40V COLOR RENDERING INDEX CRI CRI gt 80 AMBIENT TEMPERATURE 10 50 C LUMINOUS EFFICACY 97 115 lm W min COLOR TEMPERATURE 4000 K 6500 K PROTECTION CLASS IP 00 bes A LED Panel PRODUCTLIST LIST Phase PRODUCT SUPPLY VOLTAGE PANEL DRIVING PANELLIGHT TOTAL LUMINOUS HOMOGENEITY DIMENSIONS WEIGHT N Neutral CODE VDC CURRENT mA POWER W FLUX lm DISTANCE mm mm kg LPN 2509E5 12 4 700 y 850 55 250 250 0 180 L o Constant Current LPN 2513E5 12 4 1050 13 1250 99 250 x 250 0 180 N N LED Driver id LPN 2520E5 40 200 20 1900 3 250 x 250 0 180 LPN 2523E5 22 1050 23 2200 99 250 x 250 0 180 LPN 2709E5 12 4 700 9 850 33 270 x 270 0 230 LPN 2713E5 12 4 1050 13 1250 DJ 270 x 270 0 230 LPN 2720E5 40 200 20 1900 59 210x270 0 230 2723 5 22 1050 23 2200 92 270 270 0 230 LED panels must be driven by constant current LED drivers Homogeneity distance was measured with 1 5 mm opal Plexiglas mm Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice LED E PANEL LPN E hyhs EA OSRAM LED Technology included FRA PCB In accordance with EN 62031 and EN 62471 TECHNICAL DATA AMBIENT TEMPERATURE 10 50 C LUMINOUS EFFICACY 115 Im W
53. 3 430 2 195 1 BYAL XL07 S 3H 18 0 110 630x43x430 2 309 1 Measured under 230 V mains Please refer to Pictogram Table in Emergency Exit Luminaries Overview section of the catalogue for alternatives CE wus ae TL5 4P 230VAC VO Ey 2 Es EE In accordance with EN 60598 1 EN 60598 2 22 standards TECHNICAL DRAWING WIRING DIAGRAM Unswitched Line Switched Line Neutral TECHNICAL DATA ree SUPPLY VOLTAGE 230 VAC 50 60 Hz SIGN DIMENSIONS 400 x 600 mm AMBIENT TEMPERATURE 10 40 C VIEWING DISTANCE 80m RATED DURATION SI PROTECTION CLASS IP 20 BATTERY CHARGING TIME 24 48h INSULATION CLASS 2 BATTERY TYPE 3 6 V NiCd 690 43 CONTROL PANEL PANEL CHARGE Charge Status Display LED Indicates charging process of the battery WI TEST Test Button Enables testing the product without mains cuts Ml FULL Battery Status Display LED Indicates the occupancy level of the battery Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice EMERGENCY EXIT LUMINARY PRODUCT LIST _ F L U 5 E N T LA M P CODE DURATION MODE SOURCE MODE OF MOUNTING M ERCAN BYALO4 BYALO4 A CY 1 3h Non Maintained 8 W T5 Fluorescent Double sided Surface Mounted Plastic Hanger BYALO4 A CY MT 1435 Non Maintained 8 W 5 Fluorescent Double sided S
54. 31 30 ECOM2 T8 23036 1H 6V 1800 mAh 54 0 350 42 264 34 0 331 20 ECOM2 T8 23036 3H 6V 4000 mAh 55 0 355 42 264 34 0 333 30 optional y Integrated electronic ballast and emergency lighting unit in the same Non maintained operation Low rating current Silent and vibration free lighting Lighting two lamps with one electronic ballast Easy assembly of luminary due to integrated design Emergency lighting function by interruption of the unswitched phase 1 3 h duration Emergency lighting function in case of low voltage Compatible with 4 pin fluorescent lamps Prolonging the life of the lamp with warm start Short circuit open circuit and overload protection High temperature Ni Cd battery cells Overcharge and deep discharge protection Polarity reversal protection for battery Charge status display with green LED Optional test switch Optional application of 110 V operating voltage Non flammable ABS case Simple connectable terminal block C nfus H Measured with maximum power under 230 V mains EMERGENCY LUMEN FACTOR BLE EMERGENCY LUMEN FACTOR PRODUCT 15 W T8 18 W T8 30 W T8 2 8 16 15 12 36 W T8 11 9 In accordance with 61347 1 EN 61347 2 3 and 61347 2 7 TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz EMERGENCY LUMEN FACTOR BLF gt 10 AMBIENT TEMPERATURE 10 50 C BALLAST LUMEN FA
55. 310x35 0 650 In accordance with EN 61347 1 EN 61347 2 3 and EN 61347 2 7 6V AS D 35 5 35x310x35 0 800 7 2 V 2200 mAh SC 23 23x270x23 0 360 EE 6000 mAh D 6 35x372x35 1 140 Please refer to Battery Details Table in Emergency Lighting Unit Overview section of the catalogue for further battery information TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz EMERGENCY LUMEN FACTOR BLF gt 10 AMBIENT TEMPERATURE 10 50 C BALLAST LUMEN FACTOR gt 75 MAX CASING TEMPERATURE 70 C ENERGY EFFICIENCY INDEX RATED DURATION 1 36 PROTECTION CLASS IP 20 BATTERY CHARGING TIME 24 48 h INSULATION CLASS WIRING DIAGRAM TECHNICAL DRAWING PRODUCTLIST LIST i PRODUCT RATED LAMP LAMP BALLAST Nc i CODE DURATION POWER TYPE POWER FACTOR RUE es A ECOM2 PLC 21013 1H 1h 2x10 13 W 4 pin PLC 0 70 Single Lamp solia ai Ts ECOM2 PLC 21013 3H sh 2x10 13 W 4 pin PLC 0 70 Single Lamp L Unswitched Line ECOM2 PLC 218 1H 1h 2x18 W 4 0 70 Single Lamp 7 ECOM2 PLC 218 3H sh 2x18 W 4 pin PLC 0 70 Single Lamp N Neutral ECOM2 PLC 226 1H 1h 2x26 W 4 pin PLC 0 70 Single Lamp ECOM2 PLC 226 3H 3h 2x26 W 4 pin PLC 0 70 Single Lamp ECOM2 PLC 232 1H 1h 2x32 W 4 0 70 Single Lamp ECOM2 PLC 232 3H 3h 2x32 W 4 pin PLC 0 70 Single Lamp Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without p
56. 34 0 215 30 EMLUS T5 39 54 3H 6V 5000 mAh 9 9 0 023 SUA 0 215 30 EMLUS T5 40 55 1H 7 2 V 2200 mAh 2 8 0 016 39x221x34 0 215 30 Compatible with electronic and magnetic ballast EMLUS T5 40 55 3H 7 2N 6000 mAh 3 8 0 020 39x221x34 0 215 30 Non maintained operation EMLUS T5 28 80 1H 7 2V 2200 mAh 2 8 0 016 39x221x34 0 215 30 Emergency lighting function by interruption of the unswitched phase EMLUS T5 28 80 3H 7 2 V 6000 mAh 3 8 0 020 327x221x234 0215 30 1 3h duration EMLUS T5 213 14 1H 7 2V 2200 mAh 2 8 0 016 39x271x34 0 215 30 Emergency lighting function in case of low voltage EMLUS T5 213 14 3H 7 2 V 6000 mAh 3 8 0 020 0 215 30 Single or double lamp preference in case of emergency Compatible with 4 pin fluorescent lamps Prolonging the lamp life with warm start Short circuit open circuit and overload protection ini battery cells EMERGENCY LUMEN FACTOR BLF MERGENCY LUMEN FACTOR LF vercharge and deep discharge protection Measured under 230 V mains Polarity reversal protection for battery PRODUCT 8W T5 14W T5 21W T5 24 5 28W T5 35 5 39 75 49 5 54 75 80W T5 Charge status display with green LED Optional test switch EMLUS T5 30 25 17 18 16 15 16 15 13 10 Optional application of 110 V operating voltage Non flammable ABS case 4 Simple connectable terminal block optional 1 BATTERYDATA DATA VOLTAGE CAPACITY CELL TYPE CELL SIZE QTY OF CELLS DIMENSIONS WEIGHT mm mm k
57. 5 63 220 1 285 1 04 1 1 4 0 013 335x60 3X220 1 290 1 BYALOA A TY 3H 2 1 0 015 335 63 220 1 350 1 BYALO4 A TY MT 1H 335x63x220 1 370 1 Please refer to Pictogram Table in Emergency Exit Luminaries Overview section of the catalogue for alternatives BYALO4 A TY MT 3H 21 0 015 335x63x220 1 430 1 Y il BYAL04 S CY 1H 10 0 070 335x63x220 1205 1 BYAL04 S CY 3H 11 0 075 335 63 220 1 265 1 o BYALO4 S CY MT 1H 10 0 070 335x63x220 1 285 1 BYALO4 S CY MT 3H 11 0 075 335x63x220 1 345 1 04 5 1 10 0 070 Sonus xo 1 350 1 50 60 Hz ABS 60598 2 22 BYALO4 S TY 3H 11 0 075 335x63x220 1 410 1 BYALO4 S TY MT 1H 10 0 070 335x603x220 1430 1 In accordance with EN 60598 1 EN 60598 2 22 standards BYAL04 S TY MT 3H 11 0 075 335x63x220 1 490 1 Measured under 230 V mains TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz SIGN DIMENSIONS 130 x 335 mm AMBIENT TEMPERATURE ta 10 C 40 C VIEWING DISTANCE 26 m WIRING DIAGRAM TECHNICAL DRAWING RATED DURATION 1 3h PROTECTION CLASS IP 20 BATTERY CHARGING TIME 24 148 h INSULATION CLASS BATTERY TYPE 3 6 V NiCd Unswitched Line Switched Line ise Neutral 71 CONTROL PANEL PANEL CHARGE Charge Status Display LED Indicates charging process of the battery WI TEST Test Button Enables testing the product without mains cuts Ml FULL Battery Status Display LED Indicates the occupancy
58. 620 1 BYPLO1 A 1X08 W 3H 2 1 0 015 104x340x89 0 780 1 BYPLO1 A 2X08 W 1H 27 0 015 104x340x89 0 960 1 BYPLO1 A 2X08 W 3H 3 5 0 018 104x340x89 1 360 1 BYPLO1 A 1X08W SA 1H 1 4 0 013 148x426x67 1 080 1 BYPLO1 A 1X08 W SA 3H 2 0 015 148x426x67 1 235 1 BYPLO1 A 2X08 W SA 1H 2 0 015 148x426x67 1 420 1 Indoor and outdoor use BYPLO1 A 2X08 W SA 3H 3 5 0 018 148x426x67 1 820 1 Polyamid 6 case BYPLO1 S 1X08 W 1H 10 5 0 075 104x340x89 0 680 1 Polycarbonate glass BYPLO1 S 1X08 W 3H 11 0 080 104x340x89 0 840 1 Protection class 44 BYPLO1 S 2X08 W 1H 19 5 0 150 104x340x89 1 020 1 To 8W Fluorescent tube BYPLO1 S 2X08 W 3H 20 0 155 104x340x89 1 420 1 Emergency lighting function by interruption of the unswitched phase 01 5 1 08 W SA 1H 10 5 0 075 148x426x67 1 140 1 Emergency lighting function in case of low voltage BYPLO1 S 1X08 W SA 3H 11 0 080 148x426x67 1 300 1 1 3 h duration in case of emergency BYPLO1 S 2X08 W SA 1H 19 5 0 150 148x426x67 1 480 1 Battery charge and capacity status display with green LED BYPLO1 S 2X08 W SA 3H 20 0 155 148x426x67 1 880 1 Test switch High temperature Ni Cd battery cells Measured under 230 V mains Overcharge and deep discharge protection Surface and reccesed mounted Optional application of 110 V operating voltage RECESSED MOUNTING HOLE SIZE WIRING DIAGRAM TT Unswitched Line C e RYHS lt gt Switched Line TL5 4P Neutral 50 60 Hz GBR 60598 2 2
59. AINS DATA DATA PRODUCT RATED POWER MAINS CURRENT DIMENSIONS WEIGHT 1 CODE W A mm kg BOX BYALO5 TY SU 75 0 014 38x245x187 0 525 1 BYALO5 TY MT 25 0 014 38x245x187 0 605 1 BYALO5 TY SA 75 0 014 102x312x187 0 910 1 Measured under 230 V mains RECESSED MOUNTING HOLE SIZE WIRING DIAGRAM Unswitched Line Switched Line Neutral ss Wi TECHNICAL DRAWING TECHNICAL DRAWING RECESSED MOUNTED SURFACE MOUNTED 3912 102 gt gr 5 w Y AP 4 131 lt 58 102 Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice EMERGENCY EXIT LUMINARY LED PINA BYALO3 Single or double sided Anodized aluminum case Non flammable ABS side cover and hanger SMD LED application Charge and battery capacity status display with green LEDs Test switch High temperature Ni Cd battery cells Overcharge and deep discharge protection Transparent Plexiglas with screen printed or laser engraved Side lighting Ceiling mounted ceiling recessed or wall mounted Optional application of 110 V operating voltage Optional metal hanger or hook Please refer to Pictogram Table in Emergency Exit Luminaries Overview section of the catalogue for alternatives CE amp Yus A OSRAM L E D LED Technology included 230 VAC VO Ey 2
60. CT RATED LAMP LAMP BALLAST MERCEDE CODE DURATION POWER TYPE POWER FACTOR LAMP WIRING DIAGRAM TECHNICAL DRAWING DRAWING 2 5 21314 1 1h 2x13 14 W 4 5 0 70 Single Lamp ECOM2 T5 21314 3H 3h 2x13 14 W 4 pin T5 0 70 Single Lamp 2 5 221 1 1h 2x21 W 4 5 0 70 Single Lamp 2 5 221 3 3h 2x21 W 4 T5 0 70 Single Lamp ECOM2 T5 224 1H 1h 2x24 W 4 5 0 70 Single Lamp Lo ECOM2 T5 224 3H 3h 2x24 W 4 pin T5 0 70 Single Lamp Nc ECOM2 T5 228 1H 1h 2x28 W 4 5 0 70 Single Lamp Des ECOM2 T5 228 3H 3h 2x28 W 4 pin T5 0 70 Single Lamp ST qusanku ERA ECOM2 T5 235 1H 1h 2x35 W 4 pin T5 0 70 Single Lamp ECOM2 T5 235 3H 3h 2x35 W 4 pin 5 0 70 Single Lamp Pe N Neutra ECOM2 T5 239 1H Th 2x39 W 4 5 0 70 Single Lamp 2 5 239 3 3h 2x39 W 4 pin 5 0 70 Single Lamp Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice EMERGENCY LIGHTING UNIT QTY in E 5 RAT _ F L U O R ES C E N T LA M P PRODUCT BATTERY RATED MAINS CASE DIMENSIONS WEIGHT CARTON CODE CAPACITY POWER W CURRENT mm kg BOX ECO 8 ECOM T8 11518 1H 6V 1800 mAh 15 0 095 42x264x34 0 309 30 ECOM T8 11518 3H 6V 4000 mAh 16 0 100 42x264x34 0 309 30 ECOM T8 13036 1H 6V 1800 mAh 31 0 200 42x264x34 0 311 30 ECOM T8 13036 3H 6V 4000 mAh 24 0 205 42x264x34 0 311 30 ECOM T8 158 1H 6
61. CTLIST LIST 219 PRODUCT RATED LAMP LAMP BALLAST oo MUON CODE DURATION POWER TYPE POWER FACTOR TT N N _ ECOM2 PLL 211 1H 1h 2x11 W 4 pin PLL 0 70 Single Lamp 5es A ECOM2 PLL 211 3H 3h 2x11 W 4 pin PLL 0 70 Single Lamp ECOM2 PLL 218 1H 1h 2x18 W 4 PLL 0 70 Single Lamp 5 Switched Line ECOM2 PLL M ECOM2 PLL 218 3H 3h 2x18 W 4 pin PLL 0 70 Single Lamp eer 7 ECOM2 PLL 224 1H 1h 2x24 W 4 pin PLL 0 70 Single Lamp N Neutral ECOM2 PLL 224 3H 3h 2x24 W 4 pin PLL 0 70 Single Lamp Emergency Lamp ECOM2 PLL 236 1H 1h 2x36 W 4 PLL 0 70 Single Lamp ECOM2 PLL 236 3H 3 h 2x36 W 4 PLL 0 70 Single Lamp Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice BATTERY AND MAINS DATA AND MAINS DATA QTY in EMERGENCY LIGHTING UNIT INTEGRATED FLUORESCENT LAMP PRODUCT BATTERY RATED MAINS CASE DIMENSIONS WEIGHT CARTON CODE CAPACITY POWER W CURRENT mm kg Box ECOM PLC 118 1H 6V 1800 mAh 18 0 120 78 123 36 0 305 25 ECOM PLC 118 3H 6 V 4000 mAh 19 0 125 78 123 36 0 305 25 ECOM PLC 126 1H 6V 1800 mAh 24 0 160 78 123 36 0 305 25 ECOM PLC 126 3H 6 V 5000 mAh 25 0 170 78x123x36 0 305 25 Eee ECOM PLC 132 1H 6 1800 mAh 29 0 185 78 123 36 0 305 25 ECOM PLC 132 3H 6 V 5000 mAh 30 0 190 78 123 36 0 305 25 ECOM PLC 142 1H 7 2V 12200 mAh 38 0 220 78 123 36 0 305 25
62. CTOR gt 13 MAX CASING TEMPERATURE 70 ENERGY EFFICIENCY INDEX RATED DURATION 1 3h PROTECTION CLASS IP 20 BATTERY CHARGING TIME 24 48h INSULATION CLASS PRODUCTLIST LIST PRODUCT RATED LAMP LAMP BALLAST MER CODE DURATION POWER TYPE POWER FACTOR LAMP ECOM2 T8 21518 1H 1h 2x15 18 W 4 pin 8 0 70 Single Lamp ECOM2 T8 21518 3H 3h 2x15 18 W 4 pin T8 0 70 Single Lamp ECOM2 T8 23036 1H 1h 2x30 36 W 4 pin T8 0 70 Single Lamp ECOM2 T8 23036 3H 3h 2x30 36 W 4 pin T8 0 70 Single Lamp Please refer to Battery Details Table in Emergency Lighting Unit Overview section of the catalogue for further battery information Ses A 5 Switched Line 2 8 L Unswitched Lin N Neutral Emergency Lamp Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice BATTERY DATA ERY DATA VOLTAGE CAPACITY CELL TYPE CELL SIZE mm QTY OF CELLS DIMENSIONS WEIGHT kg 6V 1800 mAh se 23 5 23x225x23 0 250 6V 4000 mAh D 35 5 35x310x35 0 650 ON 2200 mAh se 35 6 23x270x23 0 360 7 2 V 6000 mAh D 35 6 39X37 2X39 1 140 WIRING DIAGRAM DIAGRAM TECHNICAL DRAWING LE EMERGENCY LIGHTING UNIT BATTERY AND MAINS DATA _ E G R AT E D _ L U L A M PRODUCT BATTERY RATED MAINS CASE DIMENSIONS WEIGHT CAEN CODE CAPACITY POWER W CURRENT mm kg BOX ECOM PLL
63. DF1 T8 41518 4x 18W T8 0 99 70 0 615 42x264x34 0 255 25 EB DF1 T5 10608 1x6W T5 1 02105 42x264x34 0 205 25 EB DF1 T5 10608 1x8W T5 0 98 15 0 135 42x264x34 0 205 25 EB DF1 T5 11314 1x14W T5 022 22 0 200 42x264x34 0 205 25 EB DF1 T5 121 1x21W T5 0 99 23 0 205 42x264x34 0 205 29 EB DF1 T5 124 1x 24W T5 0 97 24 0 215 42x264x34 0 205 2 Silent and vibration free lighting EB DF1 T5 12835 1x 22W T5 0 99 29 0 265 42 264 34 0 205 25 Prolonging the life of the lamp with warm start EB DF1 T5 12835 1x35A T5 0 99 34 0 305 42 264 34 0 205 25 Protection of defective lamps and at end of lamp life EB DF1 T5 139 1x39W T5 0 99 41 0 370 42x264x34 0 205 25 Automatic start after replacement of defective lamps EB DF1 T5 149 1 x49W T5 0 99 50 0 410 42x264x34 0 210 25 Voltage guard overvoltage indication and under voltage shutdown EB DF1 T5 154 1 54W T5 0 99 52 0 465 42x264x34 0 210 25 Constant luminous flux EB DF1 T5 180 1 x 80W T5 0 99 pue 0 670 42x264x34 0 210 25 Mains input line filter EB DF1 T5 20608 2x6W 15 0 99 22 0 190 42x264x34 0 245 25 Active power factor correction EB DF1 T5 20608 2x8W T5 0 99 30 0 250 42x264x34 0 245 25 Compatible with emergency lighting units EB DF1 T5 21314 2x 13W T5 0 99 43 0 395 42 264 34 0 245 25 Non flammable ABS case EB DF1 T5 21314 2x14W T5 0 99 A 0 400 42x264x34 0 245 25 Non flammable CEM1 PCB material EB DF1 T5 221 2x21W T5 0 99 43 0 395 42x264x34 0 255 25 Simple connectable terminal block EB DF1 T5 224 2x 24 19 0 29 47 0 425
64. ECOM PLC 142 3H 7 2 6000 mAh 41 0 260 78x123x36 0 305 25 Silent and vibration free lighting Easy assembly of luminary due to integrated design Emergency lighting function by interruption of the unswitched phase 1 3h duration Emergency lighting function in case of low voltage Compatible with 4 pin fluorescent lamps Prolonging the life of the lamp with warm start Short circuit open circuit and overload protection High temperature Ni Cd battery cells Overcharge and deep discharge protection Polarity reversal protection for battery Charge status display with green LED Optional test switch Optional application of 110 V operating voltage Non flammable ABS case Simple connectable terminal block Measured with maximum power under 230 V mains EMERGENCY LUMEN FACTOR BLF LUMEN FACTOR BLF 10 W PLC 13 W PLC 18 W PLC 26 W PLC 32 W PLC 42 W PLC 3370 30 30 22 16 15 optional Ol BATTERY DATA PL T C 4P VOLTAGE CAPACITY CELL TYPE CELL SIZE QTY OF CELLS DIMENSIONS mm WEIGHT 230 VAC VO kg en ABS 6v 1800 mAh 23 5 23x225x23 0 250 6V 4000 mAh D 35 5 35x310x35 0 650 In accordance with EN 61347 1 EN 61347 2 3 and EN 61347 2 7 5000 mAh D 35 5 35x310x35 0 800 Tow 2200 mAh S6 23 23x270x23 0 360 mo 6000 mAh D 35 35 372 35 1 140 Please refer to Battery Details Table in Emergency Lighting Unit Overview section of the ca
65. ECOM PLL 111 1H 6 V 1800 mAh 15 0 095 42x264x34 0 295 30 ECOM PLL 111 3H 6V 4000 mAh 16 0 100 42 264 34 0 295 30 ECOM PLL 118 1H 6V 1800 mAh 16 0 100 42x264x34 0 330 30 ECOM PLL 118 3H 6V 4000 mAh 17 0 105 42 264 34 0 330 30 re gt ECOM PLL 124 1H 6V 1800 mAh 23 0 155 42x264x34 0 330 30 Integrated electronic ballast and emergency lighting Unit in the same PCB FCOM PLL 124 3H 6V 4000 mAh 24 0 140 42 264 34 0 330 30 Non maintained operation ECOM PLL 136 1H 6 V 1800 mAh 29 0 195 42x264x34 0 311 30 _ Low rating current ECOM PLL 136 3H 6 V 4000 mAh 30 0 200 42 264 34 0 311 30 Silent and vibration free lighting ECOM PLL 155 1H 6 V 1800 mAh 38 0 235 42x264x34 0 307 30 Easy assembly of luminary due to integrated design ECOM PLL 155 3H 6 V 5000 mAh 39 0 240 42 264 34 0 307 30 Emergency lighting function by interruption of the unswitched phase 1 3h duration Emergency lighting function in case of low voltage Compatible with 4 pin fluorescent lamps Prolonging the life of the lamp with warm start Short circuit open circuit and overload protection High temperature Ni Cd battery cells Overcharge and deep discharge protection Polarity reversal protection for battery Charge status display with green LED Optional test switch Optional application of 110 V operating voltage Non flammable ABS case Simple connectable terminal block Measured with maximum power under 230 V mains EMERGENCY LUMEN FACTOR BLF LUMEN FACTOR BLF
66. ED driver that has 1 150 VDC output EMLUS 24V is suitable for LED strip applications up to 24 V 100 W It provides the same voltage It feeds the LEDs with 35 70 mA output current in the case of emergency light as in operation on main power in the case of emergency EMLUS XLED Compatible With EMLUS 220 Compatible With e LED Downlight COB LED 4 N e LED Strip e LED Spot Lamp J e LED Stick e LED Tube Wy e Power LED OR 8 LED Lamp gt gt e LED Spot Lamp I Io e Panel LED w EMLUS 220 is suitable for LED spot LED tube panel luminaries that operates on 220 V main power It is manufactured for the lamps and luminaries with up to 30 W output power It provides the same light as in operation on main power the case of emergency Emlus XLED 15 suitable forthe luminary with external LED driver that has 1 60 VDC output voltage It feeds the LEDs with 150 mA 300 mA output current in the case of emergency Compatible With EMLUS PW EMLUS 220 SPOT e Power LED E e LED Stick PACA TN N Murr e LED Lamp e LED Spot Lamp EMLUS PW 15 designed for serial power LED applications between 1 9 It is suitable for 1 W and 3 W power LED applications It provides 85 of the light it gives in operation on main power in the case of emergency EMLUS 220 SPOT is suitable for 3 W and 5 W LED spot lamps that operate on 220 V It provides the same light as in operation on main power in the case of emergency
67. ERATING LIGHT LIGHT INTENSITY on TYPE of BATTERY CODE DURATION MODE SOURCE ENERGY EMERGENCY MOUNTING une BYPLO1I A XLED Non Maintained 6 W LED 250 lm Surface Mounted 24 48h BYPLO1I S XLED 1 3h Maintained 6 W LED 550 lm 250 lm Surface Mounted 24 48h BYPLOTI A XLED SA Ban Non Maintained 6W LED 250 lm Recessed 24 48h BYPLO1I S XLED SA 1 3h Maintained 6W LED 550 Im 250 Im Recessed 24 48h Maintained Lights on mains and stays alight in case of the mains failure Non Maintained Lights in case of the mains failure A MESES PRODUCT RATED MAINS DIMENSIONS WEIGHT QTY in CODE POWER W CURRENT A mm kg Ei BYPLO1I A XLED 1H 2 4 16 104x340x67 650 BYPLO1I A XLED 3H 2 7 20 104x340x67 805 1 BYPLO1I S XLED 1H 12 2 55 104x340x67 708 1 BYPLO1I S XLED 3H 12 5 59 104x340x67 865 1 BYPLO1I A XLED SA 1H 2 4 16 148x426x67 1 110 BYPLO1I A XLED SA 3H 27 20 148x426x67 1 265 1 BYPLO1I S XLED SA 1H 12 2 55 148x426x67 1 168 1 BYPLO1I S XLED SA 3H 12 5 59 148x426x67 1 325 1 Measured under 230 V mains RECESSED MOUNTING HOLE SIZE WIRING DIAGRAM Unswitched Line Switched Line Neutral AA TECHNICAL DRAWING RECESSED MOUNTED TECHNICAL DRAWING SURFACE MOUNTED 104 30 O iit e LIGHT DISTRIBUTION CURVE C Haliplanes 1000 00 2700 60 0 0100 100 0
68. EXIT LUMINARIES Overview 79 Emergency Exit Luminaries LED 83 Emergency Exit Luminaries Fluorescent Lamp 99 EMERGENCY LIGHTING LUMINARIES Overview 111 LED Panel Luminary 121 Emergency Lighting Luminaries LED 123 Emergency Lighting Luminaries Fluorescent Lamp 129 Emergency Lighting Luminaries Halogen Lamp 133 Sensorlight Emergency Lighting Luminaries LED 135 LED LIGHTING SOLUTIONS Overview 139 LED Drivers 145 LED Panels 149 LED Sticks 153 ELECTRONIC BALLAST ELECTRONIC TRANSFORMER Overview 157 Electronic Ballast 163 Electronic Transformer 171 STANDARDS amp ICONS Standards amp Icons 173 ee mm LJ Be PR i POSO SE jas nmm A RETN AA a Ls M DIL 7 02 Ig Jao VAR EE ME l mes ae LI f x zu 0 o hr 3 7 WA rid n I X uu 21 N DAR gan TEL 9 4 y par BE y b y n EMERGENCY LIGHTING UNITS OVERVIEW oes EMERGENCY LIGHTING UNITS EMERGENCY LIGHTING UNIT MODELS An emergency lighting unit is an electronic circuit that provides adequate lighting to the surroundings in the case of a power Non Maintained Model EMLUS failure by the help of the battery it has provided that it is connected to light sources such as LED fluorescent and halogen used
69. G DIAGRAM 7 7 9 ze ee Unswitched Line n Switched Line Please refer to Pictogram Table in Emergency Exit Luminaries Overview section of the catalogue for alternatives Neutral IECEE RHS bsi AA a u 50 60 Hz ABS EB In accordance with EN 60598 1 EN 60598 2 22 standards TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz SIGN DIMENSIONS 140x265 mm AMBIENT TEMPERATURE ta 10 C 40 C VIEWING DISTANCE 28 m TECHNICAL DRAWING TECHNICAL DRAWING OTE E SURFACE MOUNTED RECESSED MOUNTED BATTERY TYPE 3 6 V NiCd s __ amp te 40 CONTROL PANEL CHARGE Charge Status Display LED Indicates charging process of the battery W TEST Test Button Enables testing the product without mains cuts Ml FULL Battery Status Display LED Indicates the occupancy level of the battery 195 140 55 TD 265 5 sie Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice al EMERGENCY EXIT LUMINARY LED CUPRA BYALO5 Double Sided Anodized aluminum case Non flammable ABS side cover and hanger SMD LED application Charge and battery capacity status display with green LEDs Test switch High temperature Ni Cd battery cells Overcharge and deep discharge protection Transp
70. GE CAPACITY CELL TYPE CELL SIZE CELLS DIMENSIONS WEIGHT TECHNICAL DATA mm mm kg SUPPLY VOLTAGE 230 VAC 50 60 Hz EMERGENCY LUMEN FACTOR BLF gt 10 3 6 V 1000 mAh AA 1429 2 el 0 084 AMBIENT TEMPERATURE ta 10 50 C BALLAST LUMEN FACTOR gt 737 3 6 V 3000 mAh C 26 J 26x256x26 0 240 MAX CASING TEMPERATURE 105 ENERGY EFFICIENCY INDEX 6V 1800 mAh se 23 5 2920922 0 250 RATED DURATION 1 3h PROTECTION CLASS IP 20 6V 4000 mAh D 39 9 35 310 35 0 650 BATTERY CHARGING TIME 24 48h INSULATION CLASS II 6 V 5000 mAh D 9o 5 Sry on 10x35 0 800 1240 2200 mAh SC 23 6 23 270 23 0 360 7 2V 6000 mAh D 99 6 99x3 cone 1 140 PRODUCTLIST RO D U CT LIST Please refer to Battery Details Table in Emergency Lighting Unit Overview section of the catalogue for further battery information PRODUCT RATED LAMP LAMP BALLAST CODE DURATION POWER TYPE POWER FACTOR WIRING DIAG RAM TECHNICAL DRAWING ECOM T5 10608 1H 1h 1x6 8 W 4 pin 5 0 70 ECOM T5 10608 3H 3h 1x6 8 W 4 5 0 70 ECOM T5 11314 1H 1x13 14 W 4 pin 5 0 70 La ECOM T5 11314 3H 3h 1x13 14 W 4 pin 5 0 70 N ECOM T5 12124 1H Mo 1x21 24 W 4 pin 5 0 70 E Sshehed Line T9 ECOM T5 12124 3H 3h 1x21 24 W 4 pin 5 0 70 5 5 12835 1 1x28 35 W 4 pin 5 0 70 5 8 mm ECOM T5 12835 3H 3h 1x28 35 W 4 pin T5 0 70 N Neutral e ECOM T5 139 1H 1h 1x39 W 4 pin 5 0 70 5 139 3 3h 1x39 W
71. LUS PW 1X1W 2H 3 6 V 900 mAh 2 h IE 0 011 39x221x34 0 215 30 EMLUS PW 1X1W 4H 3 6 V 1600 mAh 4 h 1 7 0 013 39x221x34 0 235 30 2 EMLUS PW 1X3W 1H 3 6 V 900 mAh 1 h 0 011 39x221x34 0 215 30 Switched Line EMLUS PW 1X3W 2H 3 6 V 1600 mAh 2 h 1 7 0 013 39x221x34 0 235 30 Unswitched Line EMLUS PW 2X1W 2H 9 6 V 900 mAh 2 h 1 9 0 012 39x221x34 0215 30 EMLUS PW 2X1W 4H 9 6 V 1600 mAh 4 h 2 9 0 017 39x221x34 0 235 30 N Neutral LED Driver _ EMLUS PW 2X3W 1H 9 6 V 900 mAh 1 h 1 9 0 012 39x221x34 0215 30 221 t EMLUS PW 2X3W 2H 9 6 V 1600 mAh 2 h 2 9 0 017 39x221x34 0 235 30 Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice BATTERY DATA RY DATA E M E RG E N CY LI G H 5 U N _ L E D VOLTAGE CAPACITY CELL TYPE uos n QTY OF CELLS xdi a mm mm g EMLUS 12V mAh AA Ws 12V 1600 mAh 5 23 10 46x113x46 0 450 oes 12V 2000 mAh D 35 10 70x310x35 1 300 Please refer to Battery Details Table in Emergency Lighting Unit Overview section of the catalogue for further battery information WIRING DIAGRAM TECHNICAL DRAWING Le N EMLUS 12V L Switched Line L Unswitched Line N Neutral LED Driver DOE ES In accordance with EN 61347 1 EN 61347 2 7 and EN 60929 TECHNICAL DATA AMBIENT TEMPERATURE 10 50 C EMERGENCY LUMEN FACTOR
72. LUS XLED300 13 24V 300 mA 13 24 VDC 5 5 8LED 5 70 W LED Driver Measured using maximum LED quantities with 7 2 V battery Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice PRODUCT LIST Con t LIST Con t E M E RG E N CY LI G H G U N IT L E D PRODUCT BATTERY RATED MAINS CASE DIMENSIONS WEIGHT EACUS CODE CAPACITY POWER W CURRENT A mm kg BOX E MLUS PW EMLUS PW 3X1W 2H 9 6 V 900 mAh 2 h DAI 0 014 39x221x34 0 215 30 EMLUS PW 3X1W 4H 9 6 V 1600 mAh 4h 3 1 0 019 39x221x34 0 225 30 EMLUS PW 3X3W 1H 9 6 V 900 mAh 1 h 21 0 014 39 221 34 0 215 30 EMLUS PW 3X3W 2H 9 6 1600 mAh 2 h 31 0 019 39 221 34 0 225 30 EMLUS PW 4X1W 2H 14 4 V 900 mAh 2 h 2 8 0 019 39 221 34 0 239 30 A EMLUS PW 4X1W 4H 144 V 1600 mAh 4 h 3 7 0 027 39 221 34 0 239 30 UP E i EMLUS PW 4X3W 1H 14 4 V 900 mAh Th 28 0 019 39x221x34 0 239 30 Compatible with all dimmable and non dimmable constant current EMLUS PW 4X3W 2H 14 4 V 1600 mAh 2 h 3 7 0 027 39x221x34 0 239 30 Sell eame etre EMLUS PW 5X1W 2H 192 V 900 mAh 2 hl 4 2 0 023 39x221x34 0 244 30 Maintained operation EMLUS PW 5X1W 4H 19 2 V 1600 mAh 4h 5 2 0 027 39x221x34 0 244 30 Emergency lighting function by interruption of the unswitched phase EMLUS PW 5X3W 1H 192V 900 mAh 1 h 0 023 39x221x34 0 244 20 1 2 and 4 h duration EMLUS PW 5X3W 2H 19 2V 1600 mAh 2 h 5
73. N 60598 1 60598 22 Height R Width Length Length TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz HEADLAMP TYPE 20 55 W Halogen AMBIENT TEMPERATURE 10 40 C CASE MATERIAL PVC RATED DURATION eon PROTECTION CLASS IP 44 BATTERY CHARGING TIME 24 96h INSULATION CLASS 12V Lead Acid PRODUCTLIST LIST PRODUCT RATED OPERATING LIGHT LIGHT INTENSITY on TYPE of BATTERY CODE DURATION MODE SOURCE ENERGY EMERGENCY MOUNTING ina AA1207 AA1Y 3h Non Maintained 1x20 W Halogen 350 lm Surface Mounted 24h AA1214 AA1Y 6h Non Maintained 1x20 W Halogen 350 lm Surface Mounted 48 h 1507 Eh Non Maintained 1x55 W Halogen 850 lm Surface Mounted 24h 1514 25h Non Maintained 1x55 W Halogen 850 lm Surface Mounted 48 h 2207 2 Eh Non Maintained 2x20 W Halogen 700 Im Surface Mounted 24h AA2214 AA2Y 3h Non Maintained 2x20 W Halogen 700 Im Surface Mounted 48 h AA2228 AA2Y 6h Non Maintained 2x20 W Halogen 700 lm Surface Mounted 96h AA2514 AA2Y Ih Non Maintained 2x55 W Halogen 1700 Im Surface Mounted 48 h AA2528 AA2Y 25h Non Maintained 2x59 W Halogen 1700 Im Surface Mounted 96h Non Maintained Lights in case of the mains failure 9 Bes A reserves the right to change the technical and visual specifications and or to discontinue the pr
74. NCY LIGHTING LUMINARIES LIGHTING LUMINARIES Escape Route Lighting Luminaries According to the standards they must be installed at a height between 2 and 4 5 meters They can be directly installed on the walls Maintained Mode ceilings or mounted ceilings or they be hung down by using components such as hangers chains and slings In this type of luminaries the lamp provides light when the mains voltage is at its normal value In the case of a main powerfailure Iit continues to provide light by means of the battery in the luminary In some versions the lamp can be switched off when desired by installing an external switch mains fuse mains A Izr test switch it Open Area Lighting Luminaries to other luminaries Open area emergency lighting luminaries have lamps with moving head These lamps can be projected towards the desired direction They can be used in large areas such as factories and garages and in surroundings that require a high level of lighting maintained emergency lighting luminary maintained lighting control switch EMERGENCY LIGHTING LUMINARIES OVERVIEW LOCATIONS WHERE THE USE OF EMERGENCY LIGHTING SYSTEM IS COMPULSORY aS The use of emergency lighting is compulsory in the following locations e All escape routes e Locations which are used for gathering e Elevators and escalators e Locations where ground level changes and the intersections of corridors e Workshops
75. NG LUMINARIES OVERVIEW EMERGENCY LIGHTING SYSTEM ESCAPE ROUTE LIGHTING Emergency lighting systems are the systems that become automatically active and provide adequate lighting when the main The emergency lighting level has to be set at 1 lux at least at any point of the central line of the escape route At the end of the power or a similar external electric supply is interrupted due to a breakdown when the power in a building 15 cut for safety emergency operating period the lighting level should not fall below the level of 0 5 lux at any point The lighting level ratio reasons in the case of a fire or an earthquake and when normal lighting is interrupted after a circuit breaker or a fuse is between the points with the highest and lowest lighting levels must not be more than 1 40 50 of the required level of the switched on emergency lighting must be provided within 5 seconds and full capacity must be reached within 60 seconds Emergency lighting for the purpose of evacuation must be on at least for one hour Emergency Lighting Emergency Escape Lighting Standby Lighting Escape Route Lighting Open Area Lighting ES En E Highly Risky Task lt 40 1 x Area Lighting OPEN AREA ANTI LIGHTING Standby Lighting Standby lighting is the emergency lighting type envisaged for the continuity of the current conditions and the operations before According to EN 1838 and EN 60598 2 22 standards areas and gathering
76. P In accordance with EN 61347 1 EN 61347 2 3 ande EN 60929 TECHNICAL DATA AMBIENT TEMPERATURE 10 50 C DEFINED WARM START 0 55 BALLAST LUMEN FACTOR BLF gt 75 INSULATION CLASS II Bes reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice 110 V ELECTRONIC BALLAST PRODUCT FLUORESCENT POWER RATED CURRENT DIMENSIONS WEIGHT antun CODE LAMP FACTOR POWER W A mm kg oes w m B0X 110 110 8 11518 1x 15W T8 0 68 9 0 115 43 185 34 0 115 30 110 8 11518 1x 18W T8 0 68 10 0 125 43x189x34 0 115 30 EB V110 T8 13036 1x30W T8 0 68 21 0 280 43x185x34 0 115 30 EB V110 T8 13036 1x 36W T8 0 68 22 0 305 43x1 89x34 0 115 30 EB V110 T8 158 1x58W T8 0 68 28 0 390 43x185x34 0 115 30 EB V110 T5 10608 1x 8W T5 0 68 5 0 065 43x185x34 0 115 30 EB V110 T5 11314 1x 14W T5 0 68 10 0 135 43x185x34 0 115 30 EB V110 T5 121 1x 21W T5 0 68 14 0 180 43x185x34 0 115 30 110 5 124 1x 24W T5 0 68 15 0 195 43 185 34 0 115 30 et no EB V110 T5 128 1x 28W T5 0 68 20 0 265 43x189x34 0 115 30 Prolonging o r EMO dE un 2 360 d E 110 5 154 1 54W T5 0 68 37 0 500 43 185 34 0 115 30 EB V110 PLL 111 1x 11WEPLL 0 68 7 0 090 43x185x34 0 115 30 Open circuit protection EB V110 PLL 11824 1x18W PLL 0 68 10 0 130 43 185 34 0 115 30 n current
77. RIG 3 9 0 020 43x185x34 0 200 30 48V 1600 mAh 1 h Compatible with LED lighting and COB LED EMLUS LED 61 90V 48V 4000 mAh 3h 3 7 0 020 43x185x34 0 200 30 Compatible with all dimmable and non dimmable constant current EMLUS LED 91 150V 0 020 43x185x34 0 200 30 EMERGENCY LUMEN FACTOR BLF LED OPERATING LED OPERATING LED OPERATING Polarity reversal protection for battery 2 1 P Hd ere DS m 01 20 VDC 20 00 14 00 10 00 6 67 5 00 ee E 21 40 VDC 18 57 13 00 9 29 5 19 4 64 1 P BEN 9 41 60 VDC 17 14 12 00 8 57 5 71 4 29 fore ANS o 61 90 VDC 11 43 8 00 5 71 3 81 2 86 91 150 VDC 10 00 7 00 5 00 3 33 2 50 A C Measured with 4 8 V battery under maximum operating voltage ES BATTERY DATA DATA i 29 VOLTAGE CAPACITY CELL CELL SIZE QTY DIMENSIONS WEIGHT In accordance with EN 61347 1 EN 61347 2 7 and EN 60929 TYPE OF CELLS ques kg 4 8 V 900 mAh AA 14 5 4 0 112 4 8 V 1600 mAh 5 23 4 23x180x23 0 200 4 8 V 2200 mAh SC 20 4 23x180x23 0 240 TEC HNI CAL DATA 4 8 V 3000 mAh C 26 4 26x196x26 0 320 4 8 V 4000 mAh D 925 4 35x248x35 0 520 SUPPLY VOLTAGE 230 VAC 50 60 Hz OUTPUT CURRENT 222 mA 48V 5000 mAh D 35 4 35x248x35 0 640 AMBIENT TEMPERATURE ta 10 50 C OUTPUT VOLTAGE 1 150 VDC CASING TEMPERATURE 70 C OPEN CIRCUIT VOLTAGE 0 VDC Please refer to Battery Details Table in
78. V 1800 mAh 35 0 225 42x264x34 0 307 30 Integrated electronic ballast and emergency lighting unit in the same PCB ECOM T8 158 3H 6V 5000 mAh 3 0 230 42x264x34 0 307 30 Non maintained operation Low rating current Silent and vibration free lighting Easy assembly of luminary due to integrated design Emergency lighting function by interruption of the unswitched phase 1 h duration Emergency lighting function in case of low voltage Compatible with 4 pin fluorescent lamps Prolonging the life of the lamp with warm start Short circuit open circuit and overload protection High temperature Ni Cd battery cells EMERGENCY LUMEN FACTOR BLF M E RG E N 10 E N FACTO R LF Overcharge and deep discharge protection PRODUCT Polarity reversal protection for battery 15 W T8 18 W T8 30 W T8 36 W T8 58 W T8 Charge status display with green LED Measured with maximum power under 230 V mains ECOM T 16 7 P 1 ne COM T8 6 15 12 11 10 Optional application of 110 V operating voltage 1 Non flammable ABS case Simple connectable terminal block us 0 31 77 TL D 4P BATTERY DATA RY DATA 230 VAC VO a o e VOLTAGE CAPACITY CELL TYPE CELL SIZE QTY OF CELLS DIMENSIONS WEIGHT mm mm kg In accordance with EN 61347 1 EN 61347 2 3 and EN 61347 2 7 6V 1800 mAh SC 23 23x225x23 0 250 6V 4000 mAh D 22 5 35 310 35 0 650 6V 5000 mAh D 35 5 39x3 10x35 0 800 Please refe
79. When the on off count rises a decline in the light flux of the lamp occurs and the lamp life decreases accordingly An electronic ballast lights the lamp without force by heating the filaments before providing a controlled current Thus the life of the lamps operating with electronic ballasts is 20 50 longer than the lamps that are subjected to the uncontrolled current caused by magnetic ballasts Trouble free Ignition Lamps that use electronic ballasts light up immediately and without flickering With electronic ballasts the ignition problems associated with the use of magnetic ballasts disappear High Power Factor The power factor which 15 at the level of 0 5 0 6 magnetic ballasts 15 above 0 95 in electronic ballasts with filter circuits Electronic ballasts do not require compensation capacitors since they do not absorb reactive power from the network PRODUCT LIST 24 V E L E CT RO N L LAST PRODUCT FLUORESCENT POWER RATED MAINS CURRENT DIMENSIONS WEIGHT Pree EB 24 CODE LAMP FACTOR POWER W A mm BOX EB V24 T5 10824 1x14W T5 0 75 17 1 10 43 185 34 0 130 30 EB V24 T5 10824 1 x 24 W T5 0 75 20 1 30 43 185 34 0 130 30 EB V24 PLL 11136 1x18W PLL 0 75 17 1 05 43 185 34 0 130 30 EB V24 PLL 11136 1x 36 W PLL 0 75 27 1 40 43 185 34 0 130 30 Measured under 24 VAC WIRING DIAGRAM TECHNICAL DRAWING Electronic Ballast CE E IE TE TL D 4P TL5 4P PL L 4
80. active they switch on the lamp not with its normal illumination capacity but with the emergency illumination level which 15 lower Since the purpose is to provide lighting at the illumination level set by the standards that allows the evacuation of the building the lamp must not be switched on at full power When designing with emergency lighting units in the emergency lighting system If the emergency e Workshops and laboratories where machinery in motion and chemicals that pose high risk are located lumen factor is high then this has an effect to reduce the number of compulsory devices to be used e Electricity distribution and generator rooms e Central battery unit rooms e Indoors car parks e Gas stations e Areas where fire alarm buttons and fire cabinets are located Emergency lighting is obligatory in following buildings STANDALONE EMERGENCY LIGHTING LUMINARY Schools and other buildings for education e All buildings with a occupant load of 200 or more e Buildings with 50 or more occupants under the ground level This method is obligatory in first and second degree earthquake zones Buildings without windows e Hotels and dormitories A standalone emergency lighting luminary 15 a lighting luminary with own battery charge circuit power voltage controller and lamp driver circuit It can be obtained by installing an emergency lighting unit in a regular lighting luminary The light source can be a fluorescent LED compact flu
81. ains EMERGENCY LUMEN FACTOR BLF LUMEN FACTOR PRODUCT 10W PLC 13W PLC 18W PLC 26W PLC 32W PLC 42W PLC EMLUS PLC 35 30 30 22 16 15 Y optional 7 BATTERY DATA VOLTAGE CAPACITY CELL TYPE CELL SIZE QTY OF CELLS DIMENSIONS WEIGHT mm mm kg C v c EJ 6V 1800 mAh Se 23 5 23x225x23 0 250 RoHS TUE 6V 4000 mAh D 35 5 35x310x35 0 650 6V 5000 mAh D 5 5 35x310x35 0 800 230 VAC Vo 7 2V 2200 mAh SC 23 6 23x270x23 0 360 50 60 Hz ABS 7 2V 6000 mAh D 35 6 35 372 35 1 140 Please refer to Battery Details Table in Emergency Lighting Unit Overview section of the catalogue for further battery information In accordance with EN 61347 1 EN 61347 2 7 and EN 60929 TECHNICAL DRAWING WIRING DIAGRAM TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz BATTERY CHARGING TIME 24 48h AMBIENT TEMPERATURE 10 50 C EMERGENCY LUMEN FACTOR BLF gt 10 E se MAX CASING TEMPERATURE 70 C PROTECTION CLASS IP 20 5es A RATED DURATION 1 3h INSULATION CLASS EMLUS PLC Switched Line L Unswitched Line N Neutral PRODUCT LIST A NUMBER OF CODE DURATION POWER TYPE LAMP EMLUS PLC 10 32 1H 10 13 18 26 32 W 4 Single Lamp B EMLUS PLC 10 18 3H 3h 10 13 18W 4 pin PLC Single Lamp EMLUS PLC 26 32 3H S 26 32W 4 PLC Single Lamp Electronic Ballast EMLUS PLC 42 1H 1h 42 W 4 PLC Single Lamp EMLUS PLC 42 3H 3h 42 W A pin PLC Single
82. ance with EN 60598 1 EN 60598 22 TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz LIGHT SOURCE 8 W 5 Fluorescent AMBIENT TEMPERATURE ta 10 40 C DIFFUSER Transparent Acrylic RATED DURATION 1 3h PROTECTION CLASS IP 20 BATTERY CHARGING TIME 24 48 h INSULATION CLASS BATTERY 3 6 V NiCd TECHNICAL DRAWING TECHNICAL DRAWING SURFACE MOUNTED RECESSED MOUNTED PRODUCT LIST PRODUCT RATED OPERATING LIGHT LIGHT INTENSITY on TYPE of BATTERY CODE DURATION MODE SOURCE ENERGY EMERGENCY MOUNTING mE 3 BYSO2 A 1 3h Non Maintained 1x8 W T5 Fluorescent 55 lm Surface Mounted 24 48h N BYSO2 A SA 1730 Non Maintained 1 8 W T5 Fluorescent 55 Recessed 24 48h BYSO2 S Won Maintained 1x8 W T5 Fluorescent 220 lm 55 lm Surface Mounted 24 48h BYSO2 S SA 13h Maintained 1x8 W T5 Fluorescent 220 lm 55 Im Recessed 24 48h wget sey BYSO2 ARM BLST Luminary 1x8 W T5 Fluorescent 220 lm Surface Mounted 24 48h BYSO2 ARM BLST SA Luminary 1x8 W T5 Fluorescent 220 Im Recessed 24 48h Maintained Lights on mains and stays alight in case of the mains failure Non Maintained Lights in case of the mains failure Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice oes EMERGENCY LIGHTING LUMINARY HATE H ALO G E N L AM P PRODUCT RATED MAINS DIMENSIONS WEIGHT 2 CODE
83. and laboratories where machinery in motion and chemicals that pose high risk are located e Electricity distribution and generator rooms eCentral battery unit rooms e Gas stations e Indoors car parks e Areas where first aid and safety kits are located e Areas where fire alarm buttons and fire cabinets are located The use of emergency lighting is compulsory in the following buildings I i _ Hospitals nursing homes buildings for education e All buildings with a occupants load of 200 or more Buildings with 50 or more occupants under the ground level JN Buildings without windows e Hotels motels and dormitories Highly hazardous locations L E D PAN E L LU M PRODUCT LIGHT POWER LIGHT POWER MAINS DIMENSIONS WEIGHT CARTON CODE W INTENSITY CONSUMPTION W CURRENT A mm kg oes ie LPN ARM LPN ARM 20X60 15W 15 1500 18 5 0 095 200 648 62 3 200 1 LPN ARM 20X60 22W 22 2150 27 0 140 200 648 62 2 250 1 LPN ARM 20X90 22W 22 2150 D 0 140 200 921 62 4100 1 LPN ARM 20X90 30W 30 2900 36 0 185 200x921x62 4 100 1 Indoor use LPN ARM 20X120 30W 30 2900 36 0 185 200x1247x62 4 900 1 Surface mounted LPN ARM 20X120 46W 46 4450 92 0 235 200 1247 62 4 900 1 Aluminum anodized body LPN ARM 30X30 09W 9 850 14 0 080 350 350 62 2 400 1 Non flammable ABS edge LPN ARM 30X30 20W 20 1950 23 0 130 350 350 62 2 550 1 Homogenous light with smooth out
84. anufacturers suggest that constant current LED drivers should be used feeding their products in order to prevent the UNS AGREED ISS decrease the life of LEDs due to the high heat caused by exposure to excess current e Long life e Various color options e High light emitting capacity e Resistance against thermal and mechanic impacts e High efficiency e t is safe from poisonous gases e High energy savings e Reliability e Low maintenance cost Environment friendly SOME OF THE TECHNICAL TERMS USED IN LIGHTING Light Flux Lumen lm Light flux is a concept related to the total amount of light emitted from a light source in a unit of time The light flux of a light source is an energy flux emitted from this light source that is measured according to the spectral sensitivity curve of a normal eye in daytime Constant Voltage LED Driver Light Intensity 1 Unit Candela cd This type of LED drivers feed the LEDs under constant voltage They are generally used in LED stick installations of 12 V 24 V 36 V Ight Intensity LI Unit Candela and 48 V where constant voltage is required A light source generally emits light flux in various directions and with different intensity The density of the light emitted towards a certain direction is referred to as the light intensity 1 LEDPANEL Luminosity L Unit cd m LED panels are LED modules that can be designed in accordance with the desired curr
85. aracteristics of electrical ligthing and similar equipment EMC immunity requirements C R H S A bsi T VRheinland 9 lt gt AA ar LED LEDSPOT i TF LEDLAMP HALOGEN Je o EJ TL5 4P TL D 4P E VAC 110VAC Se lili Lead Acid PL L 4P 100 85 30 15 BLF BLF BLF BLF OSRAM LED Technology included PL T C 4P STANDARDS amp ICONS Be A products comply with the requirements of 2006 95 EC 2006 95 EC 2004 108 EC are entitled to bear the CE mark RoHS Restriction of the use of certain Hazardous Substances in electrical and electronic equipment International and national approval marks Protection class Il device in which protection against electric shock is not based solely on the basic insulation but in which there are additional safety features such as double or enhanced insulation Safety Extra Low voltage LED or lamp usage Energy efficiency index for elecronic ballast Mains voltage for the product Insulation class Body material of the product PCB material SMD technology application Battery type International standard code Emergency Ballast lumen factor OSRAM LED Technology included engeldere Mah engeldere Cad No 105 Kat 2 avu ba Beykoz Istanbul T 90 216 479 66 77 pbx F 90 216 479 70 50 E info dbes a com www bes a com
86. arent Plexiglas with screen printed or laser engraved Side lighting Ceiling mounted ceiling recessed or wall mounted Optional application of 110 V operating voltage Optional metal hanger or hook Please refer to Pictogram Table in Emergency Exit Luminaries Overview section of the catalogue for alternatives nYus lt gt OSRAM LED 230 VO Ey 2 Es EE In accordance with EN 60598 1 EN 60598 2 22 standards TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz SIGN DIMENSIONS AMBIENT TEMPERATURE 10 40 C VIEWING DISTANCE 26m RATED DURATION 3h PROTECTION CLASS 20 BATTERY CHARGING TIME 24h INSULATION CLASS 3 6 V NiCd CONTROL PANEL PANEL CHARGE Charge Status Display LED Indicates charging process of the battery WI TEST Test Button Enables testing the product without mains cuts Ml FULL Battery Status Display LED Indicates the occupancy level of the battery PRODUCT LIST LIST PRODUCT RATED OPERATING LIGHT ROUTING TYPE CODE DURATION MODE SOURCE MODE OF MOUNTING BYALO5 TY SU oh Maintained 4x 0 1W LED Single sided Surface Mounted Plastic Hanger BYALO5 TY MT 3h Maintained 4 x 0 1W LED Single sided Surface Mounted Metal Hanger BYALO5 TY SA sd Maintained 4 x 0 1W LED Single sided Recessed Mounted Maintained Lights on mains and stays alight in case of the mains failure M
87. arge every 6 months Discharge 850mA for 10 to 20 minutes 1 2 V cell 175mA 140mA Up to 1 55 V 2450mA 850mA 1V Recommended battery permanent charge permanent charge per cell for 1 h discharge for 3 h discharge per cell 0 50 C Discharge every 6 months Discharge 550mA for 10 to 20 minutes 1 2 V cell 110mA 90mA Up to 1 55 V 1550mA 550mA 1V Recommended Bn battery permanent charge permanent charge per cell for 1 h discharge for 3 h discharge per cell 0 50 C Discharge every 6 months Discharge 400mA for 10 to 20 minutes 1 2 V cell 80mA 65mA Up to 1 55 V 1150mA 400mA 1V Recommended ae Se REM ZBI battery permanent charge permanent charge per cell for 1 h discharge for 3 h discharge per cell 0 50 C Discharge every 6 months Discharge 220mA for 10 to 20 minutes 1 2 V cell 45mA 3omA Up to 1 55 V 650mA for 1 h 220mA 1V Recommended in ROSSI AS A battery permanent charge permanent charge per cell discharge for 3 h discharge per cell 0 50 C EMERGENCY LIGHTING UNIT SOLUTIONS LED oes EMLUS LED Compatible With EMLUS 24V Compatible With P e LED Downlight e COB LED gt i LED Strip m nc m e LED Strip iwi Ta i 23 e LED Stick e LED Stick Y e Power LED e LED Spot Lamp T e LED Spot Lamp e Panel LED Emlus LED is suitable for the luminary with external L
88. ating voltage BYALO7 S 1H 10 0 070 369x43x168 1 030 I nsn n BYAL07 S 3H 11 0 075 365x43x168 1 190 1 BYALO7 S MT 1H 10 0 070 365x43x168 SO 1 BYAL07 S MT 3H 11 0 075 365x43x168 1 290 1 BYAL07 S SA 1H 10 0 070 425x43x186 275 1 BYAL07 S SA 3H 11 0 075 425x43x186 1 435 1 Measured under 230 V mains Q1 Tr R HS TL5 4P 230VAC VO En EE In accordance with EN 60598 1 EN 60598 2 22 standards Please refer to Pictogram Table in Emergency Exit Luminaries Overview section of the catalogue for alternatives WIRING DIAGRAM Unswitched Line Switched Line Neutral TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz SIGN DIMENSIONS 140 x 339 mm AMBIENT TEMPERATURE ta 10 40 C VIEWING DISTANCE 28m RATED DURATION eon PROTECTION CLASS IP 20 BATTERY CHARGING TIME 24 48 h INSULATION CLASS 3 6 V NiCd CONTROL PANEL PANEL BI CHARGE Charge Status Display LED Indicates charging process of the battery W TEST Test Button Enables testing the product without mains cuts B FULL Battery Status Display LED Indicates the occupancy level of the battery PRODUCT LIST TECHNICAL DRAWING TECHNICAL DRAWING SURFACE MOUNTED RECESSED MOUNTED PRODUCT RATED OPERATING LIGHT ROUTING TYPE CODE DURATION MODE SOURCE MODE OF MOUNTING TA BYAL06 A lah Non Maintained 8W T5 Fluorescent Double sided Lapin Surface Mounted Plastic
89. attery Status Display LED Indicates the occupancy level of the battery Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice EMERGENCY EXIT LUMINARY MAINS DATA FLUORESCENT LAMP PRODUCT RATED POWER MAINS CURRENT DIMENSIONS WEIGHT E CODE W A mm kg ay LAPI N BYALO6 LI PSOS 07 06 1 0 013 365x43x168 0 825 1 BYALO6 A 3H 2 1 0 015 365x43x168 0 985 1 BYALO6 A MT 1H 1 4 0 013 365x43x168 0 900 1 BYAL06 A MT 3H 2 1 0 015 365x43x168 1 060 1 BYALO6 A SA 1H 1 4 0 013 425x43x186 1 045 1 06 5 2 1 0 015 425x43x186 1 205 1 BYAL06 S 1H 10 0 070 365x43x168 0 885 1 Single or double sided BYALO6 S 3H 11 0 075 365 43 168 1 045 1 D A UN BYALO6 S MT 1H 10 0 070 365x43x168 0 960 1 BYALO6 S MT 3H 11 0 075 365 43 168 1 120 1 Sp qp q BYALO6 S SA 1H 10 0 070 425 43 186 1 105 1 Charge battery capacity status display with green LEDs BYAL06 S SA 3H 0 075 425x43x186 1 265 TERN UE BYALO7 A 1H 1 4 0 013 365x43x168 0 970 1 BYALO7 A 3H 2 0 015 365x43x168 1 130 1 deep discharge protection BYALO7 A MT 1H 1 4 0 015 369x43x168 1 070 BYALO7 A MT 3H 2 1 0 015 365x43x168 1 230 1 BYALO7 A SA 1H 1 4 0 013 425 43 186 1 215 1 Ceiling mounted ceiling recessed or wall mounted BYALO7 A SA 3H 2 1 0 015 429x43x186 1 379 1 Optional application of 110 V oper
90. case of the mains failure Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice EMERGENCY LIGHTING LUMINARY MAINS VALUES _ QTY i FLUORESCENT LAMP POWER IW CURRENT a Mi un a CARTON es BOX LI PSOS SAC 502 502 1 4 0 013 2 1 400 1 BYSO2 A 3H 2 1 0 015 72x342x142 1 460 1 502 5 1 1 4 0 013 74x420x170 1 860 1 BYSO2 A SA 3H 2 1 0 015 74x420x170 1 920 1 BYSO2 S 1H 10 0 070 1 500 1 502 5 3 11 0 075 72x342x142 1 660 1 BYSO2 S SA 1H 10 0 070 74x420x170 1 960 1 BYSO2 S SA 3H 11 0 075 74x420x170 2 120 1 Indoor and outdoor use BYSO2 ARM BLST 7 0 060 72x342x142 1 255 1 Powder coated white iron sheet case i ie BYSO2 ARM BLST SA 9 0 060 74x420x170 1 715 1 Acrylic Plexiglas Measured under 230 V mains Emergency lighting function by interruption of the unswitched phase Emergency lighting function in case of low voltage 1 3 h duration in case of emergency Battery charge and capacity status display with green LED Test switch High temperature Ni Cd battery cells Overcharge and deep discharge protection Surface and recessed mounted Optional application of 110 V operating voltage RECESSED MOUNTING HOLE SIZE WIRING DIAGRAM Unswitched Line Switched Line Neutral 158 2 1 TL5 4P 230 VAC E gt Es EE In accord
91. ch as va en hangers chains and slings At all exits to be used in the All points that dictate a Throughout the corridor case of an emergency change in direction The details on the installation of the emergency exit luminaries are explained EN 50172 EN 1838 standards THE SIGN PICTOGRAM FORMATS OF THE EMERGENCY EXIT LUMINARIES It is very important that the escape route Is marked clearly in order to provide a quick and safe evacuation in areas and buildings The effect of an exit sign depends on the size the color the position and the high visibility of the sign The European standards approve and support the use of pictograms that use white drawings on a green background OPERATION TYPES OF EMERGENCY EXIT LUMINARIES The lighting level ratios of green and white colors with respect to each other are defined in EN 1838 standards The color rendering index of the lamp must be at least 40 for the safety sign colors to be perceived On the escape route apart from the exit Non Maintained Model signs there must not be any illuminated signs or objects that may cause hesitation or confusion regarding the escape direction The lamp does not provide light when the main power Is at its normal value In the case of a main power failure or a main power interruption the lamp starts to provide light by means of the battery and the electronic circuit located inside the luminary Maintained Model The lamp provides light when the ma
92. circuit and overload protection High temperature Ni Cd battery cells Overcharge and deep discharge protection Polarity reversal protection for battery Charge status display with green LED Optional test switch Optional application of 110 V operating voltage Non flammable ABS case 1 Simple connectable terminal block Measured with maximum power under 230 V mains EMERGENCY LUMEN FACTOR BLF LUMEN FACTOR PRODUCT 8W T5 14W T5 21W T5 24W T5 28W T5 35W T5 39W T5 optional ECOM2 T5 30 25 17 18 16 15 16 r as 77 TL5 4P 50 60 Hz ABS 2 BATTERY DATA DATA In accordance with EN 61347 1 EN 61347 2 3 and EN 61347 2 7 VOLTAGE CAPACITY CELL TYPE CELL SIZE QTY OF CELLS DIMENSIONS WEIGHT mm mm V 1800 mAh SC 23 5 2 43225239 0 250 TECHNICAL DATA 6V 4000 mAh D 35 5 35x310x35 0 650 6 V 5000 mAh D 35 5 SbXoTBXSb 0 800 SUPPLY VOLTAGE 230 VAC 50 60 Hz EMERGENCY LUMEN FACTOR BLF gt 10 7 2 V 2200 mAh SC 23 b 23x270x23 0 360 0 AMBIENT TEMPERATURE 10 C 50 C BALLAST LUMEN FACTOR gt 75 72V 4000 mAh D 35 4 3537235 1140 CASING TEMPERATURE INES ENERGY EFFICIENCY INDEX EEES RATED DURATION 1 3h PROTECTION CLASS IP 20 Please refer to Battery Details Table in Emergency Lighting Unit Overview section of the catalogue for further battery information BATTERY CHARGING TIME 24 48h INSULATION CLASS II PRODUCTLIST LIST PRODU
93. e lamps must be controlled It must be confirmed by the operator conducting the test that the lamps provide light for at least 30 minutes for 1 hour capacity models and at least 2 hours for 3 hour capacity models The operator must inform the authorities that the batteries of the luminaries that cannot deliver the required performance have completed their life cycles e When the battery is to be changed first the power to the device must be cut and then the old battery must be replaced with an equivalent battery When replacing the battery the use of lower than required capacity batteries may cause the device not to operate whereas the use of higher than required capacity batteries may cause the device to break down e Qut of use batteries must not be thrown away with regular waste They must be sent to waste collection centers or to the manufacturer in order to be sent to these centers BATTERY DETAILS TABLE ALL PRODUCTS oes TECHNOLOGY OF BATTERY CAPACITY VOLTAGE MAXIMUM MINIMUM CHARGE MAXIMUM MINIMUM DISCHARGE TEMPERATURE USAGE THE BATTERY DESIGNATION CHARGE CURRENT CHARGE CURRENT VOLTAGE LIMIT DISCHARGE CURRENT DISCHARGE CURRENT VOLTAGE LIMIT RATING INFORMATION Discharge every 6 months Discharge 1250mA for 10 to 20 minutes 1 2 V cell 250mA 200mA Up to 1 55 V 3500 1250mA 1V Recommended in battery permanent charge permanent charge per cell for 1 h discharge for 3 h discharge per cell 0 90 C Disch
94. en Lamp EMLUS HJ is suitable for 20 W and 50 W power values that operate 12 V It provides 3096 of the light it gives in operation on main power in the case of emergency EMERGENCY LIGHTING UNIT SOLUTIONS HALOGEN LAMP Compatible With 905 1250 Spot Halogen Lamp 2 G9 Halogen gt EN Ss 7 111 Halogen Lamp EMLUS 1250 is suitable for 50 W power values that operate on 12 V It provides the same light as in operation on main power in the case of emergency BATTERY AND MAINS DATA AND MAINS DATA LED control gears Non maintained operation Emergency lighting function by interruption of the unswitched phase 1 3h duration Emergency lighting function in case of low voltage Constant current output Operation range of 1 150 V Short circuit open circuit and overload protection High temperature Ni Cd battery cells Overcharge and deep discharge protection 4 8 V 5000 mAh 3 h Measured with 3 h circuits under 230 V mains LED OPERATING LED OPERATING LED OPERATING E M E RG E N CY LI G H TI N G U N IT _ L D PRODUCT BATTERY RATED MAINS CASE DIMENSIONS WEIGHT QTY in CODE CAPACITY POWER W CURRENT A mm kg EMLUS LED EMLUS LED 01 20V 31 0 020 43x185x34 0 200 30 4 8V 2200 mAh 3h 48V 1600 mAh 1 h EMLUS LED 21 40V 3 9 0 020 43x185x34 0 200 30 48V 1600 mAh 1 h EMLUS LED 41 60V Aen ETO O
95. ent and voltage values by the serial Luminosity defines the intensity of light emitted towards a certain direction from the unit area of the surface parallel or serial parallel connection of the LEDs They work with external LED drivers LED panel installations provide a homogenous lighting in LED luminaries Compared to fluorescent lamps they have a longer life and they are more energy Light Level E Unit Lux 1 Light level is the amount of the light flux reaching the unit area of a surface in a unit of time The light level has a value of 1 lx when 1 Im of light flux is evenly projected on a surface of 1m lx lm m efficient Color Temperature Kelvin K Color temperature states the general color of the light source When we describe a light source as hot or cold what do Is providing information about its Kelvin value Low Kelvin values e g 3000K indicate hot light whereas high Kelvin values e g 8000 indicate cold light The daylight has a Kelvin value of 5000 6500 CRI Color Rendering Index LED sticks are LED modules that can be designed in accordance with the desired current and voltage values by the serial Color rendering Is the color effect that the light generates on a colored object The light source should ensure that the colors parallel or serial parallel connection of the LEDs They work with external LED drivers They can be designed in the same are perceived as they are in reality as much as possible
96. er diffuser LPN ARM 30X60 22W 22 2150 2 0 140 350x600x62 3 300 1 TUV Certified Bes A LED driver LPN ARM 30X60 46W 46 4450 52 0 235 350x600x62 3 360 1 TUV Certified Bes A emergency lighting unit LPN ARM 30X90 27W 27 2600 0 140 350 850 62 4 220 1 SMD LED application LPN ARM 30X90 39W 39 3750 45 0 200 350x850x62 4 220 1 High energy saving 50 LPN ARM 30X120 52W 52 5000 o7 0 270 350 1100 62 5 080 1 Long life time 50 000 hours LPN ARM 30X120 92W 92 8850 104 0 475 350 1100 62 5 380 1 Luminous flux range between 850 10 000 lm LPN ARM 60X60 36W 36 3450 44 0 210 600x600x62 4 610 1 Emergency lighting function by interruption of the unswitched phase LPN ARM 60X60 52W 52 5000 59 0 270 600 600 62 4 610 1 Emergency lighting function in case of low voltage LPN ARM 60X120 72W 7 72 6900 88 0 420 600 1100 62 6 970 1 1 3 h duration in emergency case LPN ARM 60X120 104W 104 10 000 118 0 540 600x1100x62 6 970 1 Charge status display with green LED Measured under 230 V mains Test switch Weights are measured with 1 hour emergency lighting units and panel luminaries High temperature battery cells Overcharge and deep discharge protection Battery charge and capacity status display with green LED Optional radar sensor WIRING DIAGRAM TECHNICAL DRAWING Unswitched Line A u Osram LED LED Technology included Switched Line Neutral 230 VAC VO FRA Oo 50 60 Hz ABS PCB 60598 2 22 In accordance with EN 60598
97. es LED driver ballast Emergency Lighting Unit Fluorescent Lamp transformer when the power is on and in the case of an emergency An Emergency Lighting Unit Fluorescent Lamp is an electronic circuit that prompts fluorescent lamps to illumiante the surroundings in the case of an emergency Bes A offers emergency lighting unit solutions complying with all power levels for 4 T8 T5 PLL and PLC fluorescent lamps L No Ho Switched Line L Unswitched Line Neutral 5 Switched Line E Unswitched Line ECOM T8 N Neutral Emergency Lighting Unit Halogen Lamp Emergency Lighting Unit Halogen Lamp is an electronic circuit that prompts 12 V halogen lamps to illuminate the surroundings in the case of an emergency Je EMERGENCY LIGHTING UNITS OVERVIEW THE EMERGENCY LUMEN FACTOR BLF LOCATIONS WHERE THE USE OF AN EMERGENCY LIGHTING SYSTEM IS COMPULSORY The emergency lumen factor or the emergency ballast lumen factor 15 the ratio of the light level transferred to the light sources such as LED fluorescent and halogen by the emergency lighting unit in the case of an emergency to the light level of the light source under normal operation It is stated as a percentage 96 in catalogues SEES EN A ES BI DS e All escape and exit routes e Gathering points e Elevators and escalators When emergency lighting units produced for LED fluorescent or certain low voltage halogen lamps become
98. es the occupancy level of the battery PRODUCT LIST LIST PRODUCT RATED OPERATING LIGHT ROUTING TYPE CODE DURATION MODE SOURCE MODE OF MOUNTING 501 SSI Non Maintained 8 W T5 Fluorescent Double sided Lapin Surface Mounted Hook Hanger BYS01 S 1 3h Maintained 8 W T5 Fluorescent Double sided Lapin Surface Mounted Hook Hanger BYS02 A Non Maintained 8 W T5 Fluorescent Single sided Lipsos Wall Mounted BYS02 S 1 3h Maintained 8 W T5 Fluorescent Single sided Lipsos Wall Mounted Maintained Lights on mains and stays alight in case of the mains failure Non Maintained Lights in case of the mains failure MAINS DATA DATA PRODUCT RATED POWER MAINS CURRENT DIMENSIONS WEIGHT QTY in CODE W A mm kg CARTON BOX 501 1 1 4 0 013 72x342x142 1 315 1 BYS01 A 3H 2 1 0 015 72x342x142 1 475 1 BYS01 S 1H 10 0 070 72x342x142 1 375 1 BYS01 S 3H 11 0 075 72x342x142 1 535 1 502 1 1 4 0 013 72x342x 142 1 460 1 BYS02 A 3H 2 1 0 015 72x342x 142 1 620 1 BYS02 S 1H 10 0 070 72x342x142 1 520 1 BYS02 S 3H 11 0 075 72x342x142 1 680 1 Measured under 230 V mains WIRING DIAGRAM TECHNICAL DRAWING Unswitched Line Switched Line Neutral 142 y 72 Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice EMERGENCY LIGHTING LUMINARIES 5e EMERGENCY LIGHTI
99. for general lighting An emergency lighting unit must be fed from a non switched phase It tracks power outage from Its own feed EMLUS switches on the light source LED fluorescent halogen connected to its outlets through the connection of an external ends In the case of a power failure it prevents panic and provides the necessary lighting for the fastest evacuation possible from driver such as a LED driver or a ballast when the power is on and in the case of an emergency the surroundings Bes A provides up to standard solutions for all types of light sources in the domain of battery operated emergency lighting units zr E Switched Line LED Driver L Uaswitehed Line Neutral k L Switched Line E Unswitched Line Neutral Emergency Lighting Unit LED An Emergency Lighting Unit LED is an electronic circuit that prompts LED lamps to illuminate the surroundings in the case of an emergency The usage of LED based lighting systems Increase rapidly day by day In this segment Bes A provides tailored solutions for its customers with its products LED fluorescent LED downlight LED spot LED panels and LED sticks g Sos A EMLUS LED Electronic Ballast Integrated Model ECOM is the combination of the emergency lighting unit and the driver the LED driver and the ballast It does not require an external ballast or a LED driver It switches on the light source by the internal driver it possess
100. g Y IF RYHSs REUS Em 1000 mAh 14 5 3 14 5x150x14 5 0 084 3 6V 3000 mAh B 26 3 26x256x26 0 240 6V 1800 mAh se 23 5 VES ASS ORS 0 250 230 VAC VO o 0 6V 4000 mAh D 35 5 35x310x35 0 650 6V 5000 mAh D gt 5 35231085 0 800 7 2 2200 mAh SC 23 6 23 270 23 0 360 In accordance with EN 61347 1 EN 61347 2 7 60929 72V 4000 mAh D 35 z 35x372x35 1 140 Please refer to Battery Details Table in Emergency Lighting Unit Overview section of the catalogue for further battery information TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz BATTERY CHARGING TIME 24 48 h DIAGRAM DIAGRAM TECHNICAL DRAWING AMBIENT TEMPERATURE ta 1090 5B C EMERGENCY LUMEN FACTOR gt 10 CASING TEMPERATURE tc 710 26 PROTECTION CLASS IP 20 RATED DURATION 1 3h INSULATION CLASS Ses A EMLUS T5 PRODUCTLIST RODUCT LIST Switched Line PRODUCT RATED LAMP LAMP MB POE MUS CODE DURATION POWER TYPE N Neutral EMLUS T5 06 08 1H 1h 6 8 W 4 5 Single Lamp Mi E21 EMLUS T5 06 08 3H 3h 6 8 W 4 pin T5 Single Lamp EMLUS T5 13 54 1H 1h 13 14 21 24 39 54 W 4 5 Single Lamp EMLUS T5 13 24 3H 3h 13 14 21 24 W 4 T5 Single Lamp EMLUS T5 39 54 3H 3 h 39 54 W 4 5 Single Lamp EMLUS T5 40 55 1H 1h 40 55 W round 4 pin T5 Single Lamp be A EMLUS T5 40 55 3H 3h 40 55 W round 4 5 Single Lamp N S EMLUS T5 28 80 1H 1h 28 35 49 80 W 4
101. h 3 5 0 020 39x216x38 0 272 20 Compatible with LED lighting and COB LED 72V 1600 mAh 1 h Compatible with all dimmable and non dimmable constant current EMLUS XLED300 01 12V 7 2V 4000 mAh 3 h 3 5 0 020 39x216x38 0 272 30 LED control gears EMLUS XLED300 13 24V 35 0 020 39x216x38 0 272 20 Maintained operation Emergency lighting function by interruption of the unswitched phase 1 3 h duration Emergency lighting function in case of low voltage Constant current output Operation range of 1 150 V Short circuit open circuit and overload protection High temperature Ni Cd battery cells Overcharge and deep discharge protection 7 2 V 5000 mAh 3 hj Measured with 3 h circuits under 230 V mains EMLUS XLED150 EMERGENCY LUMEN FACTOR BLF LUMEN FACTOR BLF LED OPERATING LED OPERATING LED OPERATING LED OPERATING LED OPERATING LED OPERATING Polarity reversal protection for battery VOLTAGE 1 a ste ile pus on al Ms GENES 42 86 30 00 21 43 14 29 10 71 rad ER ae N 22 36 VDC 42 86 30 00 21 43 14 29 10 71 SS ii 37 60 VDC 28 57 20 00 14 29 9 52 7 14 Anodized aluminum case Simple connectable terminal block EMLUS XLED300 LED OPERATING optional LED OPERATING LED OPERATING LED OPERATING LED OPERATING LED OPERATING VOLTAGE CURRENT CURRENT CURRENT CURRENT CURRENT 350 500mA 700mA 1050mA 1400mA 01 12 VDC 85 71 60 00 42 86 2957 21 43 A 13 24 VDC 85 71 60 00 4
102. he product without mains cuts B FULL Battery Status Display LED Indicates the occupancy level of the battery Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice EMERGENCY EXIT LUMINARY FLUORESCENT LAMP LAPIN 501 LIPSOS 502 Single or double sided Powder coating white iron sheet 8 W 5 Fluorescent Tube Charge and battery capacity status display with green LEDs Test switch High temperature Ni Cd battery cells Overcharge and deep discharge protection White acrylic sheet Back lighting Ceiling mounted or wall mounted Optional application of 110 V operating voltage Please refer to Pictogram Table in Emergency Exit Luminaries Overview section of the catalogue for alternatives ae TL5 4P 230 VAC Ey E gt lt 55 E In accordance with EN 60598 1 EN 60598 2 22 standards TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz SIGN DIMENSIONS 140 x 335 mm AMBIENT TEMPERATURE 10 40 C VIEWING DISTANCE 28m RATED DURATION loh PROTECTION CLASS 20 BATTERY CHARGING TIME 24 48 h INSULATION CLASS 3 6 V NiCd CONTROL PANEL PANEL CHARGE Charge Status Display LED Indicates charging process of the battery WI TEST Test Button Enables testing the product without mains cuts Ml FULL Battery Status Display LED Indicat
103. ine Neutral 128 BD TECHNICAL DRAWING RECESSED MOUNTED TECHNICAL DRAWING SURFACE MOUNTED 104 lt LIGHT DISTRIBUTION CURVE 158 34 Bes reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice EMERGENCY LIGHTING LUMINARY LED SOMON XLED BYPL01 XLED Indoor and outdoor use Polyamide 6 case Polycarbonate glass Protection class IP44 SMD LED application High energy saving 50 Long life time 50 000 hours Emergency lighting function by interruption of the unswitched phase Emergency lighting function in case of low voltage 1 3 h duration in case of emergency Battery capacity status display with green LED Test switch High temperature Ni Cd battery cells Overcharge and deep discharge protection Surface and recessed mounted Optional application of 110 V operating voltage lt gt CE nfus ae 2 230 6 E E Ge Es E In accordance with EN 60598 1 EN 60598 22 TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz LIGHT SOURCE 20 pcs SMD LED AMBIENT TEMPERATURE ta 10 40 C DIFFUSER Polycarbonate Glass RATED DURATION 1 3h PROTECTION CLASS IP 44 BATTERY CHARGING TIME 24 48 h INSULATION CLASS 3 6V NiCd PRODUCTLIST LIST PRODUCT RATED OP
104. ins voltage Is at its normal value In the case of a power failure or a power interruption the lamp continues to provide light by means of the battery and the electronic circuit located inside the luminary Minimum lighting intensity 2cd m e The lighting intensity ratio between the most and the least illuminated parts of the areas with the same color must not be greater that 10 1 e The lighting intensity ratio between the white and green area must not be less than 5 1 and more than 15 1 The green background should constitute at least 20 of the area of the sign EMERGENCY EXIT LUMINARIES OVERVIEW oes THE MAXIMUM VIEWING DISTANCE OF THE EMERGENCY EXIT LUMINARIES PICTOGRAM ALTERNATIVES FOR EMERGENCY EXIT LUMINARIES It is very important to assure that the signs that show the escape routes are visible from everywhere For this purpose The details regarding the icons that are used in the emergency exit luminaries are listed in the standards EN ISO 7010 1838 standard states that the maximum viewing distance should be determined accordance with the height of the ISO 3864 1 and ISO 16069 pictogram The standard provides the formula below Pictogram Table d sxh d Maximum viewing distance h Pictogram s height 5 100 for signs illuminated from outside s 200 for signs illuminated from within For example for an emergency exit luminary located at the end of a 20 meter corridor the height of the
105. it open circuit and overload protection High temperature Ni Cd battery cells Overcharge and deep discharge protection Polarity reversal protection for battery Measured with maximum power under 230 V mains EMERGENCY LUMEN FACTOR BLF LUMEN FACTOR BLF Charge status display with green LED PRODUCT 11 W PLL 18 W PLL 24W PLL 36 W PLL Optional test switch Optional application of 110 V operating voltage ECOM2 PLL 30 17 16 13 Non flammable ABS case Simple connectable terminal block a optional I w 5 PL L 4P DATA RY DATA 230 VOLTAGE CAPACITY CELL TYPE CELL SIZE mm QTY OF CELLS DIMENSIONS WEIGHT 50 60 Hz ABS 6V 1800 mAh SC 23 5 23X225X23 0 250 In accordance with EN 61347 1 EN 61347 2 3 and EN 61347 2 7 n 4000 mAh D 35 5 35x310x35 0 650 2200 mAh se 23 6 23Xx270x23 0 360 7 2V 6000 mAh D 35 6 35 372 35 1 140 Please refer to Battery Details Table in Emergency Lighting Unit Overview section of the catalogue for further battery information TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz EMERGENCY LUMEN FACTOR BLF gt 10 AMBIENT TEMPERATURE 10 50 C BALLAST LUMEN FACTOR gt 75 MAX CASING TEMPERATURE JADRE ENERGY EFFICIENCY INDEX RATED DURATION 1 3h PROTECTION CLASS IP 20 BATTERY CHARGING TIME 24 48h INSULATION CLASS WIRING DIAGRAM TECHNICAL DRAWING PRODU
106. it Luminaries Overview section of the catalogue for alternatives BYALO7 A LED MT 1 9 0 010 369x43x168 0 995 1 BYAL07 A LED SA TS 0 010 425x43x186 1 045 1 C v PH OSRAM BYALO7 S LED 5 0 0 030 365x43x168 0 915 1 RoHS BYALO7 S LED MT 50 0 030 365x43x168 0 995 1 1 BYALO7 S LED SA 9 0 0 030 425x43x186 1 045 LED 50 60 Hz ABS In accordance with 60598 1 60598 2 22 standards WIRING DIAGRAM Unswitched Line Switched Line Neutral TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz SIGN DIMENSIONS 140 x 335 mm AMBIENT TEMPERATURE 10 40 C VIEWING DISTANCE 28m RATED DURATION on PROTECTION CLASS IR 20 BATTERY CHARGING TIME 24h INSULATION CLASS 3 6 V NiCd KL Y TECHNICAL DRAWING TECHNICAL DRAWING SURFACE MOUNTED RECESSED MOUNTED CONTROL PANEL 425 CHARGE Charge Status Display LED Indicates charging process of the battery WI TEST Test Button Enables testing the product without mains cuts Ml FULL Battery Status Display LED Indicates the occupancy level of the battery 158 365 43 423 Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice EMERGENCY EXIT LUMINARY LED LAPIN XL LED BYAL XL06 LIPSOS XL LED BYAL XL07 Single or double sided Anodized aluminum case Non flam
107. ived from the first letters of Light Emitting Diode When LEDs are subjected to voltage they emit light international literature it is abbreviated with the code IPX1X2 The first number in IP rating X1 indicates the degree of protection through the photons they radiate at the junction areas However contrary to other incandescent lamps or fluorescent tubes the against solids while the second number 2 indicates the degree of protection against humidity and water light LEDs emit is not formed as a result of a thermal or chemical reaction Thus when compared to the conventional lighting sources LEDs have higher durability and longer life and they use the energy more efficiently LEDDRIVER DRIVER Since LEDs do not emit high heat and they are not breakable they are the best solutions to be implemented in locations where there are explosive liquids and gases with low activation energy The most important feature of the LEDS that renders them LED drivers are the electronic circuits that feed the LEDs Two types of LED drivers are used feeding the LEDs unique Is their ability to produce colors LEDs are made up of various types of chemicals The combination of the different materials defines the color of the light They emit light in a broad spectrum from infrared to ultraviolet Constant Current LED Driver Constant Current LED driver feeds the LEDs with 350 mA 500 mA 700 mA 1050 mA and 1400 mA of constant current LED m
108. lt 25 OUTPUT CURRENTS 350 700 1050 mA INSULATION CLASS II PRODUCTLIST LIST PRODUCT LED OUTPUT VOLTAGE LED CURRENT NUMBER MAXIMUM EFFICIENCY CODE CURRENT RANGE TOLERANCE of LED OUTPUT POWER LDRV 10 700 700 mA 6 12 VDC 23 2 4 8 5 W 78 Measured at full load under 230 V mains Bes reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice 145 MAINSDATA NS DATA CONSTANT CURRENT LED DRIVER PRODUCT POWER THO RATEDPOWERIW MANSCURRENT DIMENSIONS WEIGHT CODE FACTOR mm CARTON p OLDRVSO3S0 O 2 CO 3d LDRV 50 500 0 85C 29 31 0 160 39x216x38 0 240 30 LDRV 50 1050 0 95 17 59 0 270 39x260x38 0 295 25 Measured at full load under 230 V mains WIRING DIAGRAM TECHNICAL DRAWING Le L B SesA es Constant Current Po LED Driver N Neutral aus AA 230 VO E 8 EE In accordance with EN 61347 1 EN 61347 2 13 and EN 62384 TECHNICAL DATA AMBIENT TEMPERATURE 10 50 C TOTAL HARMONIC DISTORTION THD lt 30 OUTPUT CURRENTS 350 500 700 1050 mA INSULATION CLASS PRODUCTLIST LIST PRODUCT LED OUTPUT VOLTAGE LED CURRENT NUMBER MAXIMUM EFFICIENCY CODE CURRENT RANGE TOLERANCE of LED OUTPUT POWER LDRV 50 500 500 mA 30 50 VDC 10 11 17 27 W 87 LDRV 50 1050 1050 mA 30 50 VDC 2
109. ly risky task area lighting is the lighting that is manufactured for the safety of the people who are located in areas where possibly hazardous processes or conditions may occur in the case of emergency In certain systems it provides the users with opportunities for appropriate deactivation Period specified for emergency escape 1 hour EMERGENCY LIGHTING LUMINARIES OVERVIEW oes HIGHLY RISKY TASK AREA LIGHTING OPERATING MODES OF EMERGENCY LIGHTING LUMINARIES Energy distribution production and industrial process control rooms engine generator control rooms locations that have Non Maintained Mode machines motion elevators and conveyors that do not immediately stop when the power 15 cut are classified as highly risky and hazardous areas Emergency lighting level in areas with a high risk of a dangerous situation must not be less than 10 of the normal lighting level The lamp does not provide light when the main power 15 at its normal value It starts providing light in the case of a main power failure The lamp is switched on by means of the battery inside the luminary in the case of a failure Minimum lighting level mains fuse Er 15 x mains Minimum maximum lighting level ratio Ean s Color rendering index test switch TM CRI2 40 to other luminaries Period specified for emergency escape isncmatstahsd As long as the risk exists iiir gency lighting luminary EMERGE
110. mable ABS edge and plastic hanger SMD LED application Charge and battery capacity status display with green LEDs Test switch High temperature Ni Cd battery cells Overcharge and deep discharge protection White acrylic plate Back lighting Ceiling mounted or wall mounted Optional application of 110 V operating voltage Optional metal hanger or hook Please refer to Pictogram Table in Emergency Exit Luminaries Overview section of the catalogue for alternatives CE amp Yus A A OSRAM L D LED Technology included 230 VAC VO 622 2 Es EE In accordance with 60598 1 60598 2 22 standards TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz SIGN DIMENSIONS 400 x 600 mm AMBIENT TEMPERATURE 10 40 C VIEWING DISTANCE 80m RATED DURATION loh PROTECTION CLASS 20 BATTERY CHARGING TIME 24 48h INSULATION CLASS 3 6 V NiCd CONTROL PANEL PANEL CHARGE Charge Status Display LED Indicates charging process of the battery WI TEST Test Button Enables testing the product without mains cuts Ml FULL Battery Status Display LED Indicates the occupancy level of the battery PRODUCT LIST LIST PRODUCT RATED OPERATING LIGHT ROUTING TYPE CODE DURATION MODE SOURCE MODE OF MOUNTING BYAL XL06 LED A 1 3h Non Maintained 14 x 0 35 W LED Double sided Lapin Surface Mounted Hook Hanger BYAL XL06 LED S 1 3h Maintained
111. nal block No optional Unswitched Line gt EMLUS 220 N Neutral 220 VAC LED Lamp 4 Neutral LED Luminary C ari LEDLAMP 230 VAC VO Es 69 Es GJ In accordance with EN 61347 1 EN 61347 2 7 and EN 60929 TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz EMERGENCY LUMEN FACTOR 100 AMBIENT TEMPERATURE 10 C 50 C MAX OUTPUT POWER 30W MAX CASING TEMPERATURE tc JONE OUTPUT VOLTAGE 200 340 VDC RATED DURATION 173 PROTECTION CLASS IP 20 BATTERY CHARGING TIME 24 48h INSULATION CLASS PRODUCTLIST LIST PRODUCT BATTERY RATED MAINS CASE DIMENSIONS WEIGHT CODE CAPACITY POWER W CURRENT A mm BOX 7 2 V 3000 mAh 1 h EMLUS 220 10W 7 2 V 16000 mAh 3 h 4 5 0 023 39x260x38 0 340 29 12 V 3000 mAh 1 h EMLUS 220 20W 12 V 6000 mAh 3 h 2 2 0 028 39x260x38 0 365 23 12 V 4000 mAh 1 h EMLUS 220 25W 12 V 8000 mAh 3 h 5 0 028 39x260x38 0 365 23 12 V 5000 mAh 1 h EMLUS 220 30W 12 V 10000 mAh 3 h 2 2 0 028 39x260x38 0 365 23 Measured with 3 h circuits under 230 V mains Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice BATTERY DATA RY DATA EMERGENCY LIGHTING UNIT LED VOLTAGE CAPACITY CELL TYPE CELL SIZE QTY OF CELLS DIMENSIONS ud EMLUS 220 SPOT IEC 4 8 V 2200 mAh SC 23 4 23x180x23 0 240
112. ng unit in the same ECOM2 PLC 218 3H 6 4000 mAh 30 0 195 42 264 34 0 329 30 Non maintained operation ECOM2 PLC 226 1H 6V 1800 mAh 45 0 295 42x264x34 0 326 30 Low rating current ECOM2 PLC 226 3H 6V 5000 mAh 46 0 300 42x264x34 0 331 30 Silent and vibration free lighting ECOM2 PLC 232 1H 6V 1800 mAh 52 0 340 42x264x34 0 326 30 ECOM2 PLC 232 3H 6V 5000 mAh 53 0 345 42x264x34 0 330 30 Easy assembly of luminary due to integrated design Emergency lighting function by interruption of the unswitched phase 1 3h duration Emergency lighting function in case of low voltage Compatible with 4 pin fluorescent lamps Prolonging the life of the lamp with warm start Short circuit open circuit and overload protection High temperature Ni Cd battery cells Overcharge and deep discharge protection Polarity reversal protection for battery Charge status display with green LED Optional test switch Optional application of 110 V operating voltage Non flammable ABS case I Simple connectable terminal block Measured with maximum power under 230 V mains EMERGENCY LUMEN FACTOR BLF LUMEN FACTOR BLF PRODUCT 10 W PLC 13 W PLC 18 W PLC 26 W PLC 32 W PLC 42 W PLC ECOM2 PLC 35 30 30 22 16 15 optional CE aus ESI BATTERY DATA PL T C 4P VOLTAGE CAPACITY CELL CELL SIZE QTY OF CELLS DIMENSIONS WEIGHT mm kg 230 VAC VO indir ABS 6V 1800 mAh SC 5 23x225x23 0 250 6 V 4000 mAh D 35 5 35x
113. oducts without prior notice EMERGENCY LIGHTING LUMINARY 022 SENSORLIGHT LED CODE POWER IW CURRENT A mm Mikgl CARTON VATOZ LED BYSO5 seswst M 06000100 BYS05 MSL S 6W 14 5 0 170 300x300x100 1 385 1 Measured under 230 V mains WIRING DIAGRAM TECHNICAL DRAWING Anahtarlanmayan Faz Anahtarlanan Faz N tr 100 CE afus A A OSRAM L E D LED Technology included 80000 In accordance with EN 60598 1 EN 60598 22 TECHNICAL DATA AMBIENT TEMPERATURE 10 40 C CASE MATERIAL Iron Sheet BATTERY CHARGING TIME 24h PROTECTION CLASS IP 20 100 00 fir PRODUCTLIST LIST PRODUCT RATED OPERATING LIGHT LIGHT INTENSITY on TYPE of BATTERY CODE DURATION MODE SOURCE ENERGY EMERGENCY MOUNTING CHARGING BYS05 MSL S 6W 3h Maintained 6 W LED 450 lm 150 Im Surface Mounted 24h Maintained Lights on mains and stays alight in case of the mains failure Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice LED LIGHTING SOLUTIONS E 3 LED LIGHTING SOLUTIONS OVERVIEW oes Protection Class Protection Class Is the indicator of the durability of lighting luminaries against dust solids water and humidity In the The word LED was der
114. oes A PRODUCT CATALOGUE oes Established in 1995 Bes A Is one of the leading industrial enterprises that designs and manufactures Innovative products in the lighting electronics sector in Turkey Bes started production with electronic ballasts and in 1999 it extended its product range with emergency lighting units emergency exit luminaries and emergency lighting luminaries by taking Into consideration the needs of Turkish market As an innovative move Bes A started to use LED lighting technology in its designs In 2004 In 2013 Bes A started developing and manufacturing emergency lighting units highly efficient LED drivers and aluminum LED panel luminaries to be utilized in SMD LED lighting systems Consequently Bes A became the most reliable partner of its customers In LED lighting Bes A has undertaken and concluded many Innovative projects with its 20 years of knowhow and experience Bes A meets the demand from the sector with its wide product range consisting of approximately 500 products in about 50 product groups Today our company continues its operations in its indoor facility of 2 500 m with its 50 Staff who are experts in their respective areas By producing pioneering and creative works our company which manufactures fast efficiently and in high capacity adopted customer oriented service as its strategic target Always aiming to manufacture new technologies Bes A produces its mechanic and electronic design
115. onic Ballast EB DF T8 11518 1 x 18W T8 0 91 16 0 080 42x264x34 0 205 25 EB DF T8 13036 1 x 30W T8 0 97 30 0 145 42x264x34 0 205 25 EB DF T8 13036 1 x 36W T8 0 97 32 0 150 42x264x34 0 205 25 EB DF T8 158 1 x 58W T8 0 99 54 0 245 42x264x34 0215 25 EB DF T8 21518 2x15W T8 0 97 30 0 140 42x264x34 0 250 25 EB DF T8 21518 2 18W T8 0 97 32 0 150 42x264x34 0 250 25 Ra AA EB DF T8 23036 2 x 30W T8 0 99 60 0 270 42x264x34 0 250 25 EB DF T8 23036 2 x 36W T8 0 99 62 0 280 42x264x34 0 250 25 EB DF 18 258 2 x 98W 18 0 99 89 0 405 A2x264x34 0 299 25 Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice PRODUCT LIST E L F CT RO N S F O R M E R PRODUCT OUTPUT VOLTAGE OUTPUT POWER RATED MAINS CURRENT DIMENSIONS WEIGHT E CODE W POWER W A kg BOX ETR 1250 ETR 1250 12 55 37 0 095 29x155x30 0 075 50 Measured under 230 V mains WIRING DIAGRAM TECHNICAL DRAWING H lt gt 31 bes A Electronic Transformer lt gt 12V Halogen Y Lamp 41 aus O I 230 VO In accordance with EN 61347 1 TECHNICAL DATA AMBIENT TEMPERATURE 10 50 C PROTECTION CLASS IP 20 OUTPUT VOLTAGE 12 VAC Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice
116. orescent or low voltage tungsten halogen lamp In the systems where e Tall buildings standalone lighting luminaries are used the installation is quick the cable installation cost is low and increasing the capacity is e Central battery unit rooms easy They are compatible with architectural variations Je EMERGENCY LIGHTING UNITS OVERVIEW BATTERY USER S MANUAL e Emergency lighting units must be operated on a non switched phase with the voltage stated on them Power must not be interrupted except for maintenance and testing purposes Continuously turning off and on the line which the device 15 connected wears the fluorescent lamps and battery e Emergency lighting units must not be operated environments where the temperature 15 not within the operating environment temperature threshold stated on the unit for long periods If they are this may cause damage in the device and the battery e Emergency lighting units must be operated in environments that comply with the IP Protection Class conditions that are stated on the units Operating the device environments other than those stated may cause damage the device and the battery e The initial charging time of the battery is 48 hours for 1 hour capacity products and 96 hours for 3 hour capacity products For the next charges 24 hours for 1 hour capacity products and 48 hours for 3 hour capacity products are enough for the battery to be fully charged e When installing emergenc
117. r to Battery Details Table in Emergency Lighting Unit Overview section of the catalogue for further battery information TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz EMERGENCY LUMEN FACTOR BLF gt 10 AMBIENT TEMPERATURE 10 50 C BALLAST LUMEN FACTOR gt 75 MAX CASING TEMPERATURE 70 C ENERGY EFFICIENCY INDEX RATED DURATION 1 3h PROTECTION CLASS 20 BATTERY CHARGING TIME 24 48h INSULATION CLASS WIRING DIAGRAM TECHNICAL DRAWING 990 PRODUCTLIST LIST 1 UUUUUUUUUUUUUUU UL PRODUCT RATED LAMP LAMP BALLAST Lo WE CODE DURATION POWER TYPE POWER FACTOR ie E ECOM T8 11518 1H Ba 1x15 18 W 4 pin T8 0 70 S Switched Line ECOM T8 11518 3H 3h 1x15 18 W 4 pin T8 0 70 eae 7 ECOM T8 13036 1H 1h 1x30 36 W 4 T8 0 70 ECOM T8 13036 3H 3 h 1x30 36 W 4 T8 0 70 ECOM T8 158 1H 1h 1x58 W 4 pin T8 0 70 ECOM T8 158 3H 3h 1x58 W 4 T8 0 70 Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice EMERGENCY LIGHTING UNIT INTEGRATED FLUORESCENT LAMP 2 8 S BATTERY AND MAINS DATA PRODUCT BATTERY RATED MAINS CASE DIMENSIONS WEIGHT QTY in CODE CAPACITY POWER CURRENT A mm kg pda ECOM2 T8 21518 1H 6V 1800 mAh 35 0 225 42 264 34 0 326 30 ECOM2 T8 21518 3H 6V 4000 mAh 36 0 230 42 264 34 0 3
118. rior notice EMERGENCY LIGHTING UNIT BATTERY DATA _ ALO G N LAM P VOLTAGE CAPACITY CELL TYPE ae da QTY OF CELLS Mikel EMLUS HJ A 200 50 23 28 K270K23 O30 7 2V 6000 mAh D 35 6 35x372x35 1 140 Please refer to Battery Details Table in Emergency Lighting Unit Overview section of the catalogue for further battery information WIRING DIAGRAM TECHNICAL DRAWING Switched Line Unswitched Line N Neutral 12V Transformer E SO HALOGEN In accordance with EN 61347 1 EN 61347 2 7 and EN 60929 TECHNICAL DATA AMBIENT TEMPERATURE 10 50 C EMERGENCY LUMEN FACTOR 30 RATED DURATION 1 3h PROTECTION CLASS IP 20 PRODUCTLIST LIST PRODUCT BATTERY RATED MAINS CASE DIMENSIONS WEIGHT POWER W CURRENT A mm kg at EMLUS HJ 12V20W 3H 7 2 V 6000 mAh 3 h 5 8 0 032 39x221x34 0 250 30 EMLUS HJ 12V50W 3H 7 2 V 12000 mAh 3 h 6 1 0 033 39x22 1x34 0 250 30 Measured under 230 V mains Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice E EMERGENCY LIGHTING UNIT BATTERY DATA CAPACITY DIMENSIONS WEIGHT HALOGEN LAMP VOLTAGE per 6 125 cc aa Seal lead acid battery is used WIRING DIAGRAM TECHNICAL DRAWING zr Ses 0 ho 4 EMLUS 1250 2 11 L S
119. s ends on main power and in the case of emergency with its internal ballast Compatible With e 15 Circular ECOM2 T5 Fluorescent Lamp e 5 Fluorescent E Lamp ECOM2 T5 is designed for lighting 4 pin T5 fluorescent lamps on main power and in the case of emergency It is the combination of Emergency Lighting Unit and Electronic Ballast With its internal ballast on main power it lights two lamps connected to its ends and in the case of emergency it lights only one of these lamps ECOM T M Lu Compatible With e 8 Fluorescent Lamp ECOM T8 is designed for lighting 4 pin T8 fluorescent lamps on main power and in the case of emergency It is the combination of Emergency Lighting Unit and Electronic Ballast It lights one lamp connected to its ends on main power and in the case of emergency with its internal ballast Compatible With ECOM2 T8 e 8 Fluorescent Lamp ECOM2 T8 is designed for lighting 4 pin T8 fluorescent lamps on main power and in the case of emergency It is the combination of Emergency Lighting Unit and Electronic Ballast With its internal ballast on main power it lights two lamps connected to its ends and in the case of emergency it lights only one of these lamps ECOM PLL ECOM2 PLL EMERGENCY LIGHTING UNIT INTEGRATED FLUORESCENT LAMP Compatible With e PLL Compact Fluorescent Lamp gt gt ECOM PLL Is designed for lighting 4 pin PLL fluorescent lamps
120. s in its TUV Rheinland certificated R amp D laboratory Bes A giving utmost importance to the cooperation of public industry and university in product design and development became a participant of the EVATEG project which led to the establishment of the Energy Efficient LED Lighting Technologies Research Development Training and Implementation Laboratory It developed the first Emergency Lighting Unit with Microprocessor for 220 V Operated LED Lamps R amp D project in Turkey with the support of TUBITAK Our company which derives a great deal of its strength from the sustainable development principle and from its employees that adhere to this principle strictly successfully carries out many similar projects focusing on technological development The product quality of our company was approved by international institutions such as TSE TUV Rheinland and BSI Bes A also made its quality management systems compatible with ISO 9001 standards In the light of all these successes Bes A has the vision of being among the pioneering companies that represent our country abroad in the year 2020 INDEX EMERGENCY LIGHTING UNIT SOLUTIONS Overview Battery User s Manual Product Selection Guide Emergency Lighting Units LED Integrated Emergency Lighting Units LED Emergency Lighting Units Fluorescent Lamp Integrated Emergency Lighting Units Fluorescent Lamp Emergency Lighting Units Halogen Lamp EMERGENCY
121. st switch Optional application of 110 V operating voltage Non flammable ABS case Simple connectable terminal block BATTE RY DATA optional VOLTAGE CAPACITY EL CELL SIZE QTY OF CELLS DIMENSIONS WEIGHT mm kg 6V 1800 mAh SC 23 5 23x225x23 0 250 6V 4000 mAh D 35 5 35x310x35 0 650 RY HS 1 6V 5000 mAh D 35 5 35x310x35 0 800 PL L 4P 72V 2200 mAh SC 23 23x270x23 0 360 35x372x35 1 140 RER Vo LAN 6000 mAh D 35 E ABS Please refer to Battery Details Table in Emergency Lighting Unit Overview section of the catalogue for further battery information In accordance with EN 61347 1 EN 61347 2 7 and EN 60929 WIRING DIAGRAM TECHNICAL DRAWING TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz BATTERY CHARGING TIME 24 48 h E n AMBIENT TEMPERATURE 10 50 C EMERGENCY LUMEN FACTOR gt 10 5es A MAX CASING TEMPERATURE tc 70 C PROTECTION CLASS IP 20 11 RATED DURATION 1 3h INSULATION CLASS a Switched Line L Unswitched Line N Neutral PRODUCTLIST LIST PRODUCT RATED LAMP LAMP CODE DURATION POWER TYPE LAMP EMLUS PLL 11 55 1H 1h 11 18 24 36 55 W 4 PLL Single Lamp EMLUS PLL 11 36 3H 3h 11 18 24 36 W 4 pin PLL Single Lamp EMLUS PLL 55 3H 3h 55 W 4 pin PLL Single Lamp EMLUS PLL 211 24 1H 1h 2x 11 18 24 W 4 PLL Double Lamp EMLUS PLL 211 24 3H 3h 2x11 18 24 W 4 pin PLL Double Lamp
122. talogue for further battery information TECHNICAL DATA SUPPLY VOLTAGE 230 VAC 50 60 Hz EMERGENCY LUMEN FACTOR BLF gt 10 AMBIENT TEMPERATURE 10 50 C BALLAST LUMEN FACTOR gt 70 CASING TEMPERATURE pU ENERGY EFFICIENCY INDEX EEI 2 A3 RATED DURATION 1 3 PROTECTION CLASS IP 20 BATTERY CHARGING TIME 24 48h INSULATION CLASS WIRING DIAGRAM TECHNICAL DRAWING PRODUCTLIST LIST PRODUCT RATED LAMP LAMP BALLAST N CODE DURATION POWER TYPE POWER FACTOR ECOM PLC 118 1H 1h 1x18 W 4 pin PLC 0 70 ECOM PLC 118 3H 3h 1x18 W 4 pin PLC 0 70 S Switched Line ECOM PLC ECOM PLC 126 1H 1h 1x26 W 4 PLC 0 70 Unswitched Line ECOM PLC 126 3H 3h 1x26 W 4 pin PLC 0 70 N Neutral ECOM PLC 132 1H 1h 1x32 W 4 PLC 0 70 ECOM PLC 132 3H 3h 1x32 W 4 pin PLC 0 70 ECOM PLC 142 1H 1h 1x42 W 4 pin PLC 0 70 ECOM PLC 142 3H 3h 1x42 W 4 pin PLC 0 70 Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice EMERGENCY LIGHTING UNIT INTEGRATED FLUORESCENT LAMP ET BATTERY RATED MAINS CASE DIMENSIONS WEIGHT Ain CODE CAPACITY POWER W CURRENT A mm kg BOX 2 ECOM2 PLC 21013 1H 6V 1800 mAh 28 0 180 42x264x34 0 328 30 ECOM2 PLC 21013 3H 6 V 4000 mAh 29 0 185 A2x264x34 0 331 30 ECOM2 PLC 218 1H 6V 1800 mAh 29 0 190 42x264x34 07522 30 Integrated electronic ballast emergency lighti
123. technical and visual specifications and or to discontinue the products without prior notice PRODUCT LIST Con t LIST Con t DIGITAL ELECTRONIC BALLAST PRODUCT FLUORESCENT POWER RATED MAINS CURRENT DIMENSIONS WEIGHT an CODE LAMP FACTOR POWER W mm kg BOX EB DF EB DF T8 41518 4x 15W T8 0 99 63 0 285 42x264x34 0 255 25 EB DF T8 41518 4x 18W T8 0 99 67 0 305 42x264x34 0 255 25 EB DF T5 10608 1x 6W T5 0 87 11 0 055 42x264x34 0 205 25 EB DF T5 10608 1x8W T5 0 92 15 0 075 42x264x34 0 205 25 EB DF T5 11314 1 14W T5 os 21 0 095 42x264x34 0 205 25 EB DF T5 121 1x21W T5 0 95 22 0 105 42x264x34 0 205 25 EB DF T5 124 1x24W T5 75 23 0 110 42x264x34 0 205 25 Silent and vibration free lighting EB DF T5 1 2825 1 x 28W T5 0 97 29 0 135 A2x264x34 0 205 25 Prolonging the life of the lamp with warm start EB DF T5 12835 1x35A T5 0 97 33 0 150 LONDON 0 205 25 Protection of defective lamps and at end of lamp life EB DF T5 139 1x 39W T5 0 98 38 0 180 42 264 34 0 205 25 Automatic start after replacement of defective lamps EB DF T5 149 1x49W T5 0 98 51 0 230 42x264x34 0 210 25 Voltage guard overvoltage indication and under voltage shutdown EB DF T5 154 1x54W T5 0 99 50 0 230 42x264x34 0 210 25 Constant luminous flux EB DF T5 180 1 x80W T5 0 99 70 0 320 42x264x34 0 210 25 Mains input line filter EB DF T5 20608 2x 6W T5 0 94 Vy 0 105 42x264x34 0 245 25 Active power factor correction EB DF T5 20608 2x 8W T5 0 97 30 0 140 42x264x34 0
124. urface Mounted Metal Hanger BYALO4 A TY Maintained 8 W T5 Fluorescent Single sided Surface Mounted Plastic Hanger BYALO4 A TY MT 1 3h Non Maintained 8 W T5 Fluorescent Single sided Surface Mounted Metal Hanger BYALO4 S CY 1 3h Maintained 8 W T5 Fluorescent Double sided Surface Mounted Plastic Hanger BYALO4 S CY MT Maintained 8 W T5 Fluorescent Double sided Surface Mounted Metal Hanger BYALO4 S TY Maintained 8 W 5 Fluorescent Single sided Surface Mounted Plastic Hanger BYALO4 S TY MT 1 3h Maintained 8 W 5 Fluorescent Single sided Surface Mounted Metal Hanger Single or double sided Anodized aluminum case Non flammable ABS side cover and hanger 8 W 5 Fluorescent Tube Charge and battery capacity status display with green LEDs Maintained Lights on mains and stays alight in case of the mains failure Non Maintained Lights in case of the mains failure Test switch High temperature Ni Cd battery cells MAINS DATA Overcharge and deep discharge protection 5 DATA PRODUCT RATED POWER MAINS CURRENT DIMENSIONS WEIGHT 1 Back Lighting CODE w A mm kg BOX Ceiling mounted or wall mounted Optional application of 110 V operating voltage BYALO4 A CY 1H 0 013 335x063x220 1 145 Optional metal hanger or hook BYALOA A CY 3H 2 1 0 015 335 63 220 1 205 1 BYALO4 A CY MT 1H 1 4 0 013 335x032 20 1225 1 BYAL04 A CY MT 3H 2 1 0 015 33
125. witched Line E Unswitched Line N Neutral 12V Halogen Lamp 12V Transformer optional C aus E In accordance with EN 61347 1 EN 61347 2 7 and EN 60929 TECHNICAL DATA AMBIENT TEMPERATURE 10 50 C EMERGENCY LUMEN FACTOR BLF 100 RATED DURATION 1 3h PROTECTION CLASS IP 20 PRODUCTLIST LIST PRODUCT BATTERY RATED MAINS CASE DIMENSIONS WEIGHT QTY in CODE CAPACITY POWER W CURRENT A mm ka CARTON 2 12 V 72 0 035 78x123x36 0 285 25 EMLUS 1250 3H Bes A reserves the right to change the technical and visual specifications and or to discontinue the products without prior notice Measured under 230 V mains EMERGENCY EXIT LUMINARIES OVERVIEW oes EMERGENCY EXIT LUMINARIES THE INSTALLATION OF THE EMERGENCY EXIT LUMINARIES For the people to reach the exits easily during emergencies emergency exits luminaries should be installed in buildings It is compulsory to install emergency exit signs in order to show people in the building the locations of the exits to be used for evacuation and the planned exit routes from every point in the building in the case of an emergency These luminaries which can be one sided or two sided have graphic signs on them that provide orientation The luminaries can be installed on the wall on the ceiling or on the suspended ceiling They can also be hanged down by using components su
126. y lighting units the battery must be connected to the emergency unit circuit when the luminary 15 to be used In cases where It takes time for the luminary to be operative after the installation the battery must be removed from its socket after the necessary controls e The emergency lighting units and emergency exit luminaries should not be stored Inactive for too long since their batteries are already mounted Batteries that remain Inactive in the socket for long periods before the actual energy supply may irreversibly be damaged e A previously charged battery loses 15 of its capacity per month when it is not used Thus previously charged batteries must not remain inactive for more than 3 months Uncharged batteries can remain inactive for 2 years in favorable storage conditions It is not suggested to store the batteries under temperatures higher than 40 C e Batteries that remained inactive for a long time may require around two to ten charging cycles to reach full capacity e In emergency lighting unit installations the permanent line must be disconnected once in every six months and the battery capacities must be tested Before this test is conducted it must be checked that there were no interruptions in the line for 24 hours for 1 hour capacity products and 48 hours for 3 hour capacity products and that the battery is sufficiently charged Once this is checked the power to the device must be cut and the Emergency Lighting Duration of th

Download Pdf Manuals