Contents

1. M190 Sakamoto Tube Feeding Trainer 2 S SAKAMOTO MODEL CORPORATION User s Manual 151019 oF Introduction Table of Contents 1 Purpose Content 2 Usage 3 5 Precautions concerning handling 5 Washing and storage method 6 Please open your parcel and check the main unit and accessories of the product immediately upon receipt If the products are delivered damaged or with parts missing please contact our company or the distributor PAZ RATT IL j Introduction Thank you for purchasing our product Sakamoto Tube Feeding Trainer 2 Read this user s manual carefully in order to use the product for a long time appropriately This product is closely checked before factory shipment However when this product arrives open it soon and check if anything on the main unit and accessories are missing or broken Table of contents Introduction Table of Contents cccececeeeeeeees 1 Purpose Content cih sissies eee ae 2 WS AGC A E E E ei eceu cows 3 5 Precautions concerning hand ling cceeeeeeneeees 5 Washing and Storage method ccccceeseeeeseeeeees 6 Purpose Training can be performed for the following items 1 Training in nasal oral tube feeding 2 Training in gastric intestinal stoma 3 Arrival confirmation of the catheter in the stomach 4 Training in nutrient injection 5 Suction Contents 1 Main unit 7 Container for mixing pseud
2. o sputa 2 Tube nutrient catheter 8 Fr 8 Muddler for mixing pseudo sputa 3 Syringe catheter tip type 9 Silicon cap 4 Pseudo Stoma Balloon Button 10 Tray 5 Lubricant oil 11 Pseudo Tracheal Cannula 6 Pseudo sputa Usage 1 Pick the main unit out of the storage case and put it in a place where it cannot slip for example a desktop When take the main unit out hold the stand instead of the body part 2 Confirm if the Stomach Bottle and Stoma Bottle is surely fastened Fasten the Stomach Bottle tightly and match the arrow marks each other Refer to the right picture 3 To make an angle set up the support post attached to the back of the main unit Angle is preset to 30 4 Pour one cup of water about 200cc into the mouth This water is used for auscultation inside the stomach 5 Perform each training referring to the description below 1 Oral nasal catheter insertion This product supports catheter sizes from 5Fr to 15Fr Be sure to apply the attached lubricant oil to the catheter before inserting it The catheter can be fixed with tape repeatedly Remove the tape before storing the product This model can be set at an angle of 30 using the support post on the back plane The head is moveable it can be bent right and left Do not load so much when setting the head at an angle There is xiphoid process mark on the chest of the main unit it can be used to measure the leng
3. of head At that time remove the silicon cap first and then cleanse the tube 5 After cleanse dry all the parts sufficiently and assemble them Then store it in the case SAKAMOTO MODEL C O RP O RAT T O N Head office 34 Higashitakagicho Shimogamo Sakyo ku KYOTO 606 0865 JAPAN Phone 81 75 701 1135 Fax 81 75 722 5638 E mail info sakamoto model com URL http sakamoto model co jp Overseas Sales Department 9 29 Senbahigashi Minoh City Osaka 562 0035 JAPAN Phone 81 72 729 8350 Fax 81 72 729 8385 E mail trade sakamoto model com
4. sity gets proper X It is possible to adjust the viscosity by increasing or decreasing the amount of pseudo sputa powder Cautions concerning handling l When using the model while setting up the support post attached to the back of the base be careful not to load the model too much 2 When performing training wipe off water in each catheter and be sure to apply the attached dedicated lubricant oil before inserting the catheter Use the attached dedicated lubricant oil only Using some other chemicals might cause a failure 3 Do not use any permanent markers or inks on the model because they will be absorbed into the material and become impossible to remove 4 Pseudo Sputa cannot be used for human When took it in by mistake counsel a doctor as soon as possible 5 Do not use pseudo tracheal cannula for humans 6 If anything strange is detected when this model is being used stop using it and notify us as soon as possible 7 This product is a simulator for users to perform advanced training Nonetheless it does not guarantee that a similar effect can be obtained by actual treatment 8 Note in advance that this product is subject to change without notice to improve it Washing and Storage method 1 Remove cannulas simulated stoma catheters 2 Remove screws from waist and neck pmp 4 Cleanse the transparent tube parts which connect from the esophagus and tracheotomy cut
5. th to the stomach Refer to the right picture 2 Check for catheter arrival It can be checked whether the catheter is in the stomach bysucking gastric juice tap water or filling with air using the attachedsyringe and hearing the bubbling sound with a stethoscope 3 Care of a person with a gastric stoma It is possible to take care of a person with a gastric stoma Install Pseudo Stoma Button onto the abdominal 4 Injection of nutrients Confirm if the Stomach Bottle and Stoma Bottle is surely fastened Fasten the Stomach Bottle tightly and match the arrow marks each other Refer to the right Z picture Nutrients can be injected through a nasal oral catheter or a gastric stoma The stomach has a capacity of 1000 cc The Stoma Bottle has a capacity of 500cc 5 Suction Ready a Suction Catheter Size up to 15Fr can be used Ready a Pseudo Tracheal Cannula Size from ID 7 0 to 8 0 can be used When practice Suction in the Intubation Tube ready an intubation tube Size from ID 7 0 to 8 0 can be used Be sure to apply the attached lubricant oil to the catheter cannula before inserting it Please make pseudo sputa Please find next page How to make pseudo sputal Put 100ml of water into the container Sprinkle pseudo sputa ten times in it Stir it well with muddler until the mixture get thick Then sprinkle pseudo sputa five more times and stir it well see until the visco