E.5G.001SS04 说明书 EA600N系列正弦波在线互动式1K

image

Contents

1. Load Transformer Filter INVERTER CHARGER BATTERY 2 3 Main power off In main power off condition batteries will supply power to the inverter promptly then the power can be sent to user s equipments uninterruptedly after though wave filter ea Transformer Filter o 2 4 Power supply by bypass Bypass mode only happens in the following conditions 1 Over load 2 UPS failure 3 Switch on keep pressing the ON button for 3seconds UPS will be in the process of soft starting within 15seconds 4 Switch off keep pressing the OFF button for 3 seconds and UPS will turn to bypass mode Bypass Load Transformer Filter CHARGER BATTERY Hl 2 5 Battery and charging 1 Automatic self recharging occurs when UPS is connected to the main power The charger can charge the batteries up to 90 within 8 hours 2 Please keep the batteries in full power condition so as to prolong the batteries life as well as discharging time 3 There are high voltage power and electronic elements inside UPS make sure the machine not be opened by people without any technique in case of electric danger 4 Please construct and use according to this manual 3 Products features 3 1 Wide input voltage range With online synchronous voltage regulation technology and safe operating input range 165 275Vac optional 150 275V it greatly
2. Overload in AC mode 110 transfer to bypass within 60sec 120 transfer to bypass within 30sec Automatically recovery if the load capacity become normal Short Circuit Protected by Input Fuse Inverter Mode Output Voltage 100 110V 120V 220V 230V 240V 5 Output Frequency 50HZ 60HZ 1 self adaptive Output P F PF 0 6 Waveform Distortion lt 5 for Liner Load Battery Backup Time 10min PC load Transfer Time Typical value 5ms Max 8ms Efficiency 80 INV Mode Overload in INV mode 110 Shut down within 60sec 120 Shut down within 5sec Auto shut down with no load optional lt 5 Shut down within 1min Short Circuit System shut down automatically Alarm AC abnormal Once per 4sec be silent after 40s Battery low Once per 0 2sec Overload Once per 1sec Battery DC voltage 24V 24V 36V 48V H 48V Configuration standard ups tee 2X12V7AH 2X12V8AH 3X12V8AH 4X12V8AH Recharge Time 90 Capacity after 8hours Charging current long backup 10A maximum Communication charging option RS232 USB SNMP can be set to turn on off UPS automatically Others Output Sockets Customized upon request Surge protection optional EMC EN62040 2 2006 EN61000 3 2 2006 EN61000 3 3 2008 IP Level IP20 Ambient Temperature oC 40 C Ambie
3. 3 In normal using condition the life time of battery is near 1 2 years If battery temperature and discharging frequency is high the life time will be near 0 5 1 year 4 Along with the running time the performance of battery is generally degraded If the discharging time reduces to be 80 of initial time performance is degrading fast So battery maintenance should be done every month 5 Battery maintenance of long backup UPS keep doing the maintenance is vital to protect the precision equipment on main power off condition Clear the dust on battery Check the connection cables between batteries are loose or not if necessary replace the cable even the battery Keep the battery and cable connection tight Note The discharging test above is just a simple test to check the battery charging status and performance If needing know more exact information about battery charging status should contact with battery supplier locally 7 3 Trouble shootings UPS can offer reliability to load If abnormal accident occurs advise you go to local service center so as to prevent more damage and unnecessary fee When UPS is in abnormal status you can refer the following trouble shootings If can t solve problem please get in touch with local distributor or contract direct with our company 15 Phenomenon Confirmation and Solution Main power is normal main power indicator is off 1 whether Cable is loose 2 whether fu
4. Place having severe vibration Outdoor Use powder extinguisher if there is fire around UPS Not to use liquid extinguisher in case danger of electric shock Place sockets nearby UPS so as to pull out sockets and cut off the power in an emergency situation The product can provide 100 power output within range of rated voltage 25 if out of the range the output power meets as followings P 100 75 50 25 U v 145 175 280 Input voltage and output power Warning Equipment must be connected to the ground 1 The equipment must be connected to the ground Make sure connect UPS to the ground well while connecting AC to supply power 2 The power sockets must be 15A 250V or above this specification if the capacity of UPS is above 2KVA 3 Incorrect operation may cause heavy loss Please make sure to use the ups correctly according to this manual 2 Working principle 2 1 System circuit diagram Bypass AVR MAINS _ _ N Load Transformer INVERTER CHARGER BATTERY 2 2 Normal power supplies When UPS works in normal condition miscellaneous waves of high frequency of main power are eliminated by wave filter after this batteries group are charged by the chargers in one route and keep the batteries in full power condition another route is through UPS stabilizer the power will be sent to user s equipment after the wave filter r Bypass aly AVR MAINS
5. Pure Sine Wave UPS 1 3KVA OUTDOOR UPS a CONTENTS Safety And Summary Product components Installation and usage Maintenance Packing List Working principle lt lt lt lt s s 546 4seseeeeseo sProd cts features Torani see an Technical specification 1 Safety And Summary Please obey the items below to ensure the security Charge battery longer than 12hrs before using After battery discharge or being stored more than three months 12hrs recharging in time is required The product is designed for group computers could not connect with the sensitive load motor fridge etc Keep above 50cm away from the display while installing the product It is normal that the case surface temperature go up to 50 C during using Do not use UPS with overload Do not open UPS cover in case danger of electric shock maintenance and battery replacement should be handled by technicians UPS inner short circuit will cause electric shock or fire danger Do not put any liquid vessel on UPS Cut off power rapidly if equipment work abnormal Make sure not to keep or use the product in following environment No good air circulation Place having flammable gas corrosive material or lots of dust Place under abnormal high or low temperature above 40 C or below 0 C and high humidity above 90 Place having direct sunlight or close to heater equipment
6. red is positive black is negative 12 2 Secondly please plug UPS into main power then turn on the input switch on the rear panel And then use multimeter to ensure UPS and battery connector s polarity identification and voltage to be compliant 1 15 times as the ups rating DC voltage if the batteries are full 7 Maintenance 7 1 Preventative Maintenance Preventative maintenance to UPS system can guarantee the reliability and long time service do some test per month as follows 1 Shut down UPS Refer the operation steps for details 2 Check the vents not be blocked 3 Check whether there is so much dust covering the surface 4 Check the connection of input output as well as batteries to see whether itis firm and the insulating barrier of cable also Make sure UPS not damp Start UPS Refer the operation steps for details 7 Keep UPS working for 5 minutes on battery mode with little testing load until it alarm because of battery low voltage there is supposed to be no other alarm ou information during this period if any please contact the local service center or the supplier 7 2 Battery Maintenance Valve Regulated Lead Acid battery is used in this UPS The life time can be reduced by bad operating environment frequently discharging and sharply temperature rising Even battery is not used the performance can be gradually degraded That is why we advise to do a discharging every 3 months if there is no po
7. bypass the LCD will display PWR DN as well as the icon A or the word full 3 10 Intelligent communication ports with intelligent computer monitoring function option This series UPS can be monitored by PC through RS232 USB or SNMP card it can provide UPS on off control and auto file saving function for different kinds of systems such asWINDOWS98 NT 2000 ME 2003 XP Vistar 1 This series UPS can automatically detect the condition of the mains failed and battery in low voltage as well as UPS other working data LCD UPS 2 When the mains is failed the system will make countdown to automatically save files shut down system and UPS 3 It can set system power supply time make history record of UPS working status the mains status and so on When the system is in shut down countdown it can set UPS self detection and time for UPS on and off 7 4 Technical specification VA Rating 500VA 1000VA 1500VA 2000VA 3000VA Real Power Rating 300W 600W 900W 1200W 1800W Display Indicator on Panel LED LCD plus LED display LED for outdoor UPS AC Mode Types Of Load Ancillary equipments such as PC display group computers and so on Input Voltage 100 110V 120V 220V 230V 240V 25 35 25 optional Input Frequency 45 65 Hz transfer to battery mode if out of this range Output voltage 100 110V 120V 220V 230V 240V 25 Input PF AC DC 98 Efficiency 96 AC Mode
8. switch on rear panel of UPS firstly and then press the start button on front panel for 3 seconds UPS will output power normally from Inverter 1 Daily start Press the start button ON for 3 seconds UPS will output normally in 15 seconds 2 Daily shut down Press the shut down button OFF on front panel for 3 seconds UPS will turn to bypass mode if the main power is on And bypass LED will be on at the moment Otherwise the ups will shut down Cautions 1 Please start UPS then computer load when starting computer and shut down the computer load then UPS 2 Normally it s unnecessary to switch off UPS so as to charge the batteries 3 It will transfer to battery mode once the mains power goes off please save your files or do other emergency deal to PC or other load 6 3 ON and OFF operation after long time storage of UPS 1 If exceeds 7 days please shut down as follows press the OFF button on front panel and then switch on the input breaker on the rear panel 2 1f you will use the ups after more than 3 months storage please start the UPS as same as the initial starting and make sure it working more than 12 hours to charge battery keeping the battery full condition is good to prolong the life span 6 4 Installation of Long backup type UPS Warning In order to ensure equipment and human safety it must be installed by qualified technicians 1 Firstly please connect batteries with battery cable and install them well Note
9. make the batteries discharging and recharging less often than usual and prolong the batteries using life effectively 3 2 Auto switching machine function Please turn off the input switch in the rear if no need the automatic switch on function Supply the main power and turn on the input switch in the rear of the ups it will start automatically 15s later forming stabilized power for the load Batteries will supply power promptly when the main power is off after finishing discharging UPS will shut down automatically with long ringing UPS will restart automatically if main power recovers after auto shutting down and recharge the batteries as well 3 3 Humanized alarm system UPS will alarm 1 5seconds when main power is off and normal inverter gets to work the sound will be dispelled automatically after 40 seconds in order not to disturb the working environment UPS starts the alarm automatically with long ringing when the batteries will be nearly exhausted the frequency is 1 0 2seconds in order to remind people that batteries are used up and UPS will be off soon When batteries are almost used up UPS will shut down automatically to protect the batteries 3 4 Protective functions of online UPS Overload on main power condition on main power condition UPS will alarm for 60s if the load is over 110 then it will turn to bypass mode with ringing disappeared either Normal condition will recover if load ha
10. nt Humidity 10 90 No Condensing Noise lt 45dB f 420X145X215 Dimension mm DxWxH 355X145X215 355x145X315 H 475X190X335 i n P 510X325X245 Packing Dimension mm 450X 325X245 750x325x245 H 590X320X465 Net Weight kg 14 5 15 5 18 5 27 Gross Weight kg 15 5 16 5 19 5 28 60 j Note 1 Data after with H means the ups is long backup type with external battery 2 The data above is for the standard ups varying from the special units of customers 3 Dimension of outdoor UPS is subject to the real machine 5 Product components 5 1 LCD front panel 1 Brief view of front panel 1 LCD display screen 2 Bypass indicator orange 3 Output indicator green 4 UPS working status indicator 6 ON Starting button 5 AC power indicator orange 7 OFF Shut down button 2 Introduction of the indicative lamp 1 LCD display screen Display input and output voltage frequency battery and load capacity 2 Bypass indicator orange the light is off when UPS is working with main power input 3 Output indicator green the light is on when UPS is working 4 UPS Working condition indicator green red the green light is on when there is main power input red light is on when main power is off 5 AC indicator orange the light is on when there is input main power 6 ON Starting button Start UPS by pressing it for 3 seconds UPS output power normally in 15 seconds daily star
11. occurring at the transfer between AC and batteries so as to ensure the disturbance and damage to equipment in the lowest level 3 6 LCD and LED display panel The intuitive LED and LCD display makes users can easily learn the information of battery capacity load capacity as well as the whole system working status a 3 7 Automatically shut off when there is no load in inverter mode option When UPS is in inverter mode the alarm will disappear after 40 seconds and at the same time it will automatically detect the load capacity if the load is less than 5 UPS will consider as no load and will automatically shut off after 1 minute to ensure the battery full and prolong the battery life 3 8 Automatically distinguish output frequency The mains frequency is 50HZ or 60HZ when the UPS is connected with the mains it can automatically detect the mains frequency and the UPS output frequency will keep the same as the mains frequency 50HZ or 60HZ before even the main power failed 3 9 Battery detection The product can work with monitor software to detect battery at fix time if there is any fault such as battery cable open circuit or battery failure the UPS can detect the faulty information through communication ports to inform user Meanwhile the UPS has self protection function to shut down the charging system and will turn to bypass mode for the UPS with bypass model when the mains is normal then itis power supplied by
12. s been decreased to anormal range Overload on normal inverting condition on inverting power condition UPS will alarm with long ringing if load is over 110 it will supply power again if load was decreased to a normal range within 60 seconds and stop ringing at the same time Otherwise it will be shut down itself Users need to turn on it manually by pressing the ON button in the front panel or wait for the recovering of main power Overload on abnormal inverting condition on inverting power supply condition UPS will alarm with long ringing when load is over 125 ups will automatically shut down after 5s end users need to turn on it manually by pressing the ON button in the front panel or wait for the recovering of main power Short circuit protection on inverting power condition if the output of the ups meets transient crest current and short circuit strike it will be limited in some degree if over 10ms system will shut down automatically Users should turn on manually press the ON button in the front panel or wait for the mains recovered If on main power supply condition the input fuse will get broken as the first protection and then ups will turn to inverting mode 3 5 Phase lock function On main power condition system tracks the main power phase position automatically which can ensure the wave form of inverting output voltage going simultaneously with the main power s It can lower the spike pulse and surge voltage
13. se is burnt UPS can not stay in mains mode The mains power indicator is off with the buzzer ringing even the UPS input plug has been inserted to main power socket and power switch is pushed whether fuse is burnt or not After pulling out the UPS plug use screwdrivers to revolve the fuse counterclockwise and get it out Check that whether the fuse is fusing if so need replacement Mains Mode no problem battery mode can not work Whether the battery is not charged or not Whether UPS is not switched on When power is off computer will stop working When main power is normal start UPS Charge the battery for more than ten hours and then start the UPS When mains connected UPS beeps for 60 seconds then transfer to bypass When noAC input UPS shut of automatically after 60 seconds beeping Check UPS is overload or not When UPS transfer to battery mode but shut off immediately When AC connected UPS stay in bypass mode and LCD shows PWR ON A me or Fault Battery connection cables open circuit or battery damage 8 Packing List 1 UPS 1 unit 2 User Manual 1 copy 3 Warranty 1 copy 3 Battery connection cable 1 piece only for long backup model 4 Others are according to customer needs 16
14. ting 7 OFF Shut down button shut down UPS by pressing it for 3 seconds working through bypass with main power input and the bypass light is on daily shut down 9 5 2 Brief diagram and introduction of back panel 10 1 SNMP Optional i 2 Output sockets 3 USB RS232 Optional gt 4 Input switch 5 Fuse 6 Input 7 DC input 6 Installation and usage 6 1 Product installation 1 Close the equipments for example computer master pull out the power wire from the main power socket 2 Put the UPS to the suitable position with good ventilation at least 150mm ambient space around the vent and fan 3 The power wire of equipments which need UPS for sample computer master and so on should be connected to output sockets of UPS Others should be connected to the common main power sockets 4 Connect the input plug of the ups to main power socket make sure L N be right and the ground line is ok 11 6 2 Start shut down 1 On main power condition Turn on the input switch on back panel of UPS UPS will start self testing and output through bypass and will be in normal condition in 15 seconds the output indicator and working status indicator green of UPS will be on the bypass indicator is off user can start PC and other load at this moment 2 On battery condition main power off Turn on the input
15. wer off for long time There are maintenance steps in the following the performance will get degraded very fast please keep the following operations of battery maintenance in mind 1 Connect AC input switch on UPS and charge battery up to 8 hours Look out load running status which is connected to UPS 2 Keep the load and record the total power then shut off AC input UPS transfer to battery mode till shut off automatically record the discharging time Also keep the discharging time record in order to refer it later 13 7 3 Outdoor UPS Parts Lightning arrester Maintenance bypass switch DC input switch Input output switch Host connection cable Indicator Manual DC PW ON key Manual PW Off key Dry contact RS232 SNMP O Option DC input Red anode Black cathode Power supply input output terminals Input fuse Inner battery i 2 Power DC voltage space Dimension mm 500VA 24VDC 40AH 2 245 430 550 40AH 2 245 430 550 1000VA 24VDC 120AH 2 245 470 900 1500VA 36VDC 120AH 2 245 470 900 40AH 4 penta 2000W 48 24VDC 120AH 2 245 470 900 14 OThe total power of load power consumption is calculated in unit of Watt Olf the marking of UPS just shows power capacity in VA we need to multiply power factor if no marking it is 0 6 to calculate in unit of Watt Olf there is just Ampere value marked then multiply rated voltage and power factor to calculate in Watt