Home

ASunDar User Manual

image

Contents

1. Drop 1A Lower Limit of Resistance 0 5000 Delay Test Time 1 000 Voltage Drop 2A Error Code picture 3 digital cable setting picture 4 charging cable test As shown in picture 3 there are three items for setting You can choose the upper limit or lower limit resistance for setting As showed in picture 4 when finishing the setting it may begin the test The resistance values can be set according to your different need We advise to set the delay test time as default 1S or more than 1S for a stable connection of cable In the setting interface press the up and down key to move cursor press the left key to return to the previous interface press the right key to enter the setting interface see picture 5 Upper Limit of Resistance Picture 5 setting interface The interface as shown in picture 5 press left and right key to move cursor accordingly Press the up or down key the value located in cursor will be changed by one unit toward up or down respectively When pressing right key for 2seconds parameter setting will be confirmed and then you can continue to make a next setting AsunDar Shenzhen ASunDar Electronics Co Ltd Resistance cable actual resistance Voltage Drop 1A 1A volt Oresult QA voltage drop Voltage Drop 2A 2A voltage drop Error Code error code picture 6 Digital cable testing As shown in picture 6 when connecting the USB cable in a test situation the tes
2. AsunDar User Manual ASD911 USB Cable Tester VR 1 0 Shenzhen ASunDar Electronics Co Ltd www asundar com AsunDar Shenzhen ASunDar Electronics Co Ltd Introduction Thank you for purchasing products made by Shenzhen ASunDar Electronics Co Ltd The user manual tells you how to use the ASD911 USB cable tester correctly ASD911 USB tester is shorted for the tester in the user manual Please read this user manual carefully before use Attentions Please check below items when open the carton If the tester model is what you ordered If all enclosures including the tester certification user manual and warranty bill are enclosed 3 If any problem to occur during delivery such as broken missing damage or other defect please contact our company or your supplier promptly Please check if the voltage of power supply is within allowed range before power on If it is beyond the range of voltage it may make the tester unable to work and even burned out Please make sure that the power supply meets the safety specification otherwise there may cause electric shock accidents With continuously improving for product the manual will be revised based on product upgrade or specification change If there is any difference with product usage please look up latest version of the manual or contact our customer service staff When you have any question about our product please call our customer service staff for help Ser
3. Frequency Range 50Hz Tester Size HxWxD 76mm 150mm 176mm Packaging Size HxWxD 145mm 265mm 230mm Net Weight 1 25Kg Weight Total Weight 1 85kg lll Quick Start This chapter will give you a simple introduction for the basic function of the tester It makes you understand and use the tester quickly 3 1 The functions introduction on the tester panel x3 ASunDar Shenzhen ASunDar Electronics Co Ltd E N N T V Th j vig D y CDleft port micro usb mini usb USB2 0 right port USB2 0 D type up key right key down key left key LCD display 3 2 Basic Operation 3 2 1Quick Start Firtly connect the power to the tester and switch the power on and then LCD will show turned on display as shown in picture 1 Wait the system initializing for a few seconds the tester goes into the standby status as shown in pircture 2 then the tester finishes its turn on successfully Digital Cable Test Charging Cable Test Auto Test picture1 turn on display picture2 standby screen As shown in picture 2 there are three function options Through pressing left key for 2 seconds goes to setting status as shown in picture 3 Pressing right key goes to testing status as shown in picture 3 Click the up down left and right key can choose parameter on the menu by moving cursor when you enter a setting status AsunDar Shenzhen ASunDar Electronics Co Ltd Setting of Digital Cable Resistance 1 0000 Voltage
4. ed on occasion please fill in the Warranty Certificate correctly for warranty and give it to us as soon as possible Please keep the Warranty Certificate well If missed it can not be provided again usually After warranty period we provide repair service in charge to meet customer s demand As for repair cost please refer to latest revision Repair Price List of our company If you have any question please contact the local agents or contact our company directly Shenzhen AsunDar Electronics Co Ltd reserves the right to interpret this agreement Shenzhen ASunDar Electronics Co Ltd Company address Fourth Floor of Building B Hongshengyuan Industry Park No 339 of Bulong Road Bantian Longgang District Shenzhen China Telephone 86 755 28531900 Fax 0755 28530909 Website www asundar com
5. nished if the icon of USB Digital Cable turns blue color the cable is a USB digital cable If the icon of USB Charging Cable becomes blue it is a charging cable The long shape icon in the middle shows the current through the cable right now If there is no any change with the two icons and also the tester buzzes three times it means that the cable is a bad cable The error code of cable shows on the right corner the fourth line and you can check the details of error through seeing table 1 And now if needed press right key for retesting again press left key will return to standby situation AsunDar Shenzhen ASunDar Electronics Co Ltd 3 2 2 Error code rules Error code X X X X un C D i i resistance short circuit misconnection open circuit Error Code Table Table 1 A B C D Code Description Code Description Code Description Code Description 0 Ok 0 Ok 0 OK 0 Ok 1 Bigger resistance 1 V wrong 1 V open circuit 2 2 D wrong 2 D open circuit 3 V amp D short circuit 3 V wrong D wrong 3 V open D open 4 4 D wrong 4 D open circuit 3 V amp D short circuit 5 V wrong D wrong 5 V open D open 6 D amp D short circuit 6 D wrong D wrong 6 D open D open 7 V amp D D hort circuit 7 V D D wrong 7 V D D open circuit 8 8 V wrong 8 V open circuit 9 V amp V short circui
6. t 9 V wrong V wrong 9 V open V open A D amp V short circuit A D wrong V wrong A D open V open circuit B V amp D V short circuit B V D V wrong B V D V open circuit C D amp V short circuit C D wrong V wrong C D open V open D V amp D V short circuit D V D V wrong D V D V open circuit E D amp D V short circuit E D D V wrong E D D V open circuit F All short circuit F All lines wrong F All open circuit IV Condition Requirements Item Parameter Specification Temperature 0 C 55 C Humidity Max 85 Dust Pollution level 2 Altitude Under 2000 meters Temperature 30 C 70 C Humidity Max 90 Work condition Storage condition AsunDar Shenzhen ASunDar Electronics Co Ltd Warranty Agreements 1 One year warranty since the purchasing date according to issued receipt date coo N OQ tn mL It is out of warranty scope in below situation A Damage caused by improper delivery use or storage such as liquid invasion dampened compressed fallen etc after purchase B Repair or remake not approved by our company C Damage caused by natural disaster such as the thunder and lightning earthquake fire floods etc Fault or damage caused by other factors not by machine itself D Only with warranty certificate or purchase document E The accessories are out of warranty scope Once the tester has any problem or is damag
7. t will begin and the test results will be shown on the display screen immediately If the actual resistance value is within the setting range the tester will give a buzz sound and display green color in the circle it means the test pass If the actual value is beyond the setting range the tester will give three times of buzz sounds and display red color in the circle it means the test failure The texts on the right screen show actual values The top line shows actual resistance of single charging cable The second and third line show the voltage drop with 1A and 2A current conducting separately The fourth line shows the error code of cable see details in table 1 If the code is 0000 it shows USB cable is accepted You can press right key for retesting again Pressing left key will return to standby situation Pressing left key for 2seconds will enter setting situation Resistance Voltage Drop 1A Voltage Drop 2A Error Code Picture 7 Picture 7 shows the test of charging cable without digital cable s D and D The operation is the same as digital cable test AsunDar Shenzhen ASunDar Electronics Co Ltd Resistance Voltage Drop 1A USB Digital Cable Voltage Drop 2A Error Code Picture 8 Automatic test Picture 8 shows auto testing which can identify whether the cable is digital cable with D D cable or charging cable without D amp D cable You can see two USB icons on the left After test fi
8. vice hotline 86 755 28531900 400 0755 308 AsunDar Shenzhen ASunDar Electronics Co Ltd Contents I Product Introduction ll Technical Specification lll Quick Start IV Condition Requirements V Warranty Agreements AsunDar Shenzhen ASunDar Electronics Co Ltd I Product Introduction This tester is mainly used for testing quality of USB cable and applicable for many digital cables with UBS2 0 D type port Min USB and Micro USB port Function amp Feature Using 32 bit ARM high speed processor USB assembly unit with separate design easy to replace Measure the resistance of USB cable accurately Can be set the upper and lower limits of cable resistance It helps choose qualified USB cables through resistance value needed by yourself It can find the fault reason short circuit open circuit core misconnection and help for repair Automatically test after inserting the USB cable then quickly tells the test result with sound indicating and displaying on the color screen at the same time It can identify at once that the USB cable is a digital cable with 4cores inside or a charging cable with 2cores inside Test delay time can be set manually ll Technical Specification Item Parameter Specification Cable impedance Resistance testing range 1mQ 1000mO Readback Resolution Resistance 1mO Readback Resist 0 5 Accuracy 25 C eee Voltage Range AC220V 10 Power Input

Download Pdf Manuals

image

Related Search

Related Contents

Manual de instrucciones  Hall Switch VTNS1060A User`s Manual  Mode d`emploi K 05 NF, K 08 NF, K 06 NF, K 09 NF Mode d  User manual  Moxa TCC-120  Linear DXR-701 User's Manual  neoStampa - Inèdit Software SL  iRobot® Create  Rev 1  補足資料2:Mobile+Oneカタログ(PDF 3210KB/6  

Copyright © All rights reserved.
Failed to retrieve file