1. Instruction Manual Hitachi Air Purifier with Humidifying Function Model EP A8000 Thank you for purchasing a Hitachi air purifier This air purifier is for home use only Do not use it for any other purposes be sides purifying air Please read this instruction manual carefully before using this product to ensure the unit is operated correctly For future reference keep this manual in an easily accessible place Read the Safety Precautions from page E 4 to E 7 to ensure correct use i T_S EP A6000 indd 1 HITACHI Inspire the Next Contents Features Name of Each Component Operation Buttons and Indicators Accessories Safety Precautions Cautions on Use Pa ee ee ee ee Preparations for Operation Setting Filter in Unit 658 We 38s oe ae as te Ss awe ep 8 car se o Inserting Batteries into Remote Controller gt Filling Water Tank Kaane Reed Sear te a o oar cee ow installation ee ee ee ee ee Operating Air Purifier Using Remote Controller Starting Operation et ee Sell set cet Set cet sar es a vee ar Wer et Selecting Operation Mode 7 Switching Airflow Rate ccrrrrtt Max Operation ee aa a B a Using Timer 88 hes a eane ee aerate w ms Using the Control on Unit Memory Function Sensors Auto Detection Memory Function Bi S80 Gee Se va cee Ser sae Soy JR S
2. Safety Precautions Continued A N CAUTION Miscellaneous Securely hold the grip when carryingthe unit Damaging or dropping it may cause injury When you attach or detach the panel and water tank do it slowly and carefully Otherwise water may leak out or fingersmay be pinched Use dry cell batteries after reading the relevant precautions Refill water in the water tank on a daily basis using tap water and clean the tank periodically according to the instructions in the Cleaning section of this manual Continued use without cleaning may propagate molds or bacteria due to dirt and water scale which may lead to unpleasant odors In rare cases this may cause a health risk to those who are hyperactive In rare cases this may cause a health risk to those who are hyperactive In such a case please seek medical advice Only use fresh tap water Otherwise it may cause deformation or degenerationof parts unit failure or unpleasant odors due topropagation of molds or bacteria Do not use hotwater over 40 C purified water alkali ion water mineral water well water or other similar typesof water Do not put organic solvents chemicals perfume or air freshener into the water tank Do not drink or allow anyone to drink water in the water tank and water tray Doing so may cause a health threat lt p Do not leave the detached water tank with its cap closed AD The inner pressure of the tank changes according to a
3. Do not leave the water tank removed from the body When attaching the tank cap be sure to install it on the body Changes in the inner pressure of the tank according to ambient temperature change may cause water leakage deformation or damage Do not place the body anywhere exposed to high temperature and direct sunlight Inner pressure of the tank changes according to ambient temperature change and may cause water leakage or deformation or damage Remove the water tank before pulling out the water tray Pulling out the water tray without removing the water tank may result in deformation and damage of the water tank and water tray When removing the water tray from the body quietly pull it out by lifting it upward at a slight angle The bottom part may damage the floor Do not mount the water tank with the water tray removed The water tank may fall If water is present in the water tank or water tray the humidification function operates regardless of the operation mode If you do not need humidification do not fill the water tank and water tray with water When installing the empty water tank on the product do so by lifting up the handle E 12 T_S EP A6000 indd 11 z 2012 08 02 rl i i Installation Install the unit on a level stable and sturdy surface Avoid any location close to cooling or heating appliances and select a well ventilated area Keep the unit at least 90 cm away from th
4. When using the unit together with the Hitachi air purifier with ionizing function Pressing the O button on the remote controller in front of the Hitachi air purifier with ionizing function model whose ionization setting release is switched using the remote controller sets and releases ionization Furthermore pressing the ionizing button on the remote controller of the model with the ionizing function sets and releases eco operation Dimmer Control lf you feel uncomfortable about indicator lightings when you go to sleep press Q button on the unit for 3 seconds or longer to dim the indicators anea nes uog2942q QNy s1osua uonoun4 Howen E Press button for 3 seconds or longer The indicators are dimmed How to set cancel Every time you press the Q button for approximately three seconds Set and Cancel will alternate The setting will be saved in memory E 21 T_S EP A6000 indd 17 z 2012 08 02 veal Cleaning m Before cleaning be sure to stop operation and unplug the power cord from the AC outlet Do not splash water on the unit Doing so may cause a unit failure Do not use volatile solvents such as gasoline thinner benzene wax kerosene alcohol etc or polishing Z WARNING powder or detergent used for kitchen or laundry Such chemicals could cause deformation discoloration damage or removal of prints Do not tip over or tilt the unit Whe
5. i Filter Replacement Replacement Interval The filters are consumable items parts The standard life of the dust filter is approximately 8 years and that of the deodorizing filter is approximately 10 years Testing was conducted according to JEM1467 of the Japan Electric Machine Industry Association If 5 cigarettes are smoked per day Dust filter Years until the air purifying time is double that of when the filter is new Deodorizing filter Years until the deodorizing rate is reduced by half compared to when the filter is new Wi The dust filter should be replaced early if its color resembles any of the colors on the dirtiness label attached to the unit e The colors on the dirtiness label are shown as a guide only Depending on the installation location the actual color of the contaminated filter may differ from the color shown on this label ra ok For a room where Dirtiness label there have only been a few people Filter Replacement Guide Replace the filter smoking cigarettes early if Rs color For a room where becomes similar to many people have been either color smoking cigarettes WFor the deodorizing filter replacement interval use approximately 10 years as a guide Replace the filter earlier when the filter performance is degraded WiThe filter may need to be replaced earlier depending on the installation location and conditions of use When it becomes difficult to remove dirt or odor rep
6. P E 14 airiow rate Press this button to start or i EE Press this button to switch eco Button gt P E 21 F F operation mode Press this button to start or F stop eco operation SN ndsti on gt P E 17 Setting Press this button to set ea Off timer VESE silio E gt P E 1 Press this button to start EAO Ae TO gt P E 20 HITACHI Press this button to switch sensor sensitivity seuOsseooy SiOyeo pu pue suong uoneedo JUeBUCdOD YOR JO eWeN Saunjee E Note The remote control may not work in a room where inverter lighting apparatus or electronic quick start lighting apparatus is used or when the infrared receiver is exposed to direct sunlight The remote controller works best when aimed squarely at the remote infrared receiver Whenever possible use the controller from a point directly in front of the unit E 3 T_S EP A6000 indd 3 z 2012 08 02 re i Safety Precautions Please read the following safety precautions carefully before using the unit To prevent injury to the user or other people and property damage the following instructions must be followed Also read the precautions appearing in the text carefully to ensure correct use E Definition of each indication Incorrect operation that are carried out as a result of ignoring instructions will cause harm or damage The seriousness is classified by the following indications Meanings of Symbols This symbol indica
7. a level stable surface Avoid carrying the unit with water in the tank Stop using the unit immediately and contact your dealer for repairs Stop using the unit immediately and contact your dealer for repairs Cancel the dimmer control setting gt P E 21 Press the reset button gt P E 22 2012 08 02 oe i i Following Conditions Are Normal Noise vibration Snapping noise sounds when plugging power be It is because electric components are energized cord into the AC outlet when power is supplied This is normal Vibration is caused by fan rotation This Unit vibrates during the Max operation nodal The noise is produced by air bubbles when water in the Bubbling NOISE water tank is supplied to the water tray This is normal This is a switching sound of the shutter This is normal vv v Clicking noise sounds during operation Heat odor When first using the odor of the parts inside the body may be noticeable Otherwise gt the deodorization performance of the filter has declined gt P E 27 Or odor may have contaminated the humidifying filter Clean the humidifying filter gt P E 22 E 24 The remote control or the remote control gt The control substrate is built into the body ae Pee E Therefore the remote control or remote receiving part IS warm control receiving area may get warm The wind coming out of the outlet smells Operation other A
8. a unit failure Do not touch or move the unit angle or lift the unit during operation Moving the operating unit may cause the fan to come in contact with the inner case which may generate unnecessary noise and possibly unit failure Do not place the unit in a location exposed to direct sunlight Direct sunlight may cause deformation discoloration or malfunction Do not subject the remote controller to impact Do not drop the remote controller or step on it and do not place any object on it Doing so may cause a unit failure Do not subject the water tank to impact Water may leak from the tank and wet the floor Also water may drip from the tank cap and wet the floor Do not use near a television or radio Doing so may interfere with broadcasts Install the unit 2m or more away from such devices 2012 08 02 re i Preparations for Operation Lay a soft cloth or similar material beneath the unit to protect the floor against scratches ZAN CAUTION No cleaning effect can be expected if the filter is inserted while still inside the plastic bag It may also cause a malfunction Do not tip over or tilt the unit Due to vibrations during transport etc deodorant powder black white may emerge from the filter When removing the filter from the bag and attaching it to the body please be careful to ensure your hands clothes and surroundings etc are not soiled
9. eh i eo L Using Remote Controller Here we describe how to operate the unit using the remote controller For information about using the control on the unit please refer to page E 18 Starting Operation Unit indicator Section Remote Controller Unit ononon n on HumidityLevel 30 40 50 60 70 Approx Strong Skin Air Air Purify Pollen Deodorizaton Humidify Moisturize Timer 4hrs Sensor a bme El tt e menn T Clean Max Blinking Humidifying a T o l o Sensor Max Setting O HITACHI EPR 35 During the first 3 minutes after the power cord is Securely insert the power plug plugged in the unit will check the air condition of the room and save it in memory During that time the Air into the AC outlet Sensor and Humidity Level 50 indicators will blink You may start the operation within 3 minutes after plugging it in In this case too the Air Sensor and Humidity Level 50 indicators will continue to blink After 3 minutes have elapsed the indicators will stop blinking a 70 Approx On Off Strong Skin Air Air Purr Pollen Deodorization Humidify Moisturize Timer 4hr Sensor 5 10 bys Press EN Max Blinking Humitying pe Filter T Operation starts and the indicators are lit The Air Purify mode indicator lights up in green WY Strong Skin Air Air Purify
10. hole blocked by dust or other obstacles Is sensor sensitivity low Was the ambient air clean when the unit power cord was plugged into the AC outlet s the unit installed in a location away from odor or dust Is the odor sensor hole blocked by dust or other obstacles Is the dust sensor covered with dust Is the odor sensor hole blocked by dust or other obstacles 3 gt YYYY V VV VTVVVVVVY V V V Securely insert the power plug into the AC outlet Switch on breaker Clean the pre filter referring to the Pre filter in Cleaning P E05 Replace the filter referring to the Filter Replacement The filter may need to be replaced earlier depending on the installation location and conditions of use gt P E 27 Insert the batteries with correct polarities gt P E 11 gt P E 11 Clean the remote infrared receiver gt P E 26 Press the airflow button and select Auto Sensor or another airflow rate gt P E 1 5 E 1 8 Airflow rate will not decrease when humidity is low Replace the batteries Change the sensor sensitivity setting Press the airflow button and select Auto Sensor or another airflow rate gt P E 15 E 18 Clean the odor sensor gt P E 26 Change the sensor sensitivi ae Y SP E 20 Change the airflow rate Or open a window and plug the power cord into the AC outlet when ambient air is clean gt P E 19 Relocate the air unit Cl
11. precautions should also be followed for the dust filter E 9 T_S EP A6000 indd 8 z 2012 08 02 ae i Preparations for Operation Continued 4 Install the dust filter on the purifier 1 Insert the filter all the way until the label dust filter position indicator is hidden Dust filter O Attach the pre filter to the body 1 Incline the pre filter and stably insert the latch nub into the insertion holes of the body in order from top to bottom Close the pre filter on the body filter side Rotate the knobs of the pre filter in two locations to the right to lock into the insertion holes of the body eee Insertion hole 4 Lightly pull the pre filter to confirm it does not come off O Reinstall the panel on the purifier 1 Insert the two tabs on top of the panel into the two holes on the purifier Gently push the bottom of the panel until it clicks to close it securely Insert into the hole E 10 i T_S EP A6000 indd 9 z Insert the latch nubs of the pre filter in order from top to bottom 2012 08 02 rk Inserting Batteries into Remote Controller Remove the battery Insert batteries and close the cover compartment cover Insert the two provided AAA R03 batteries with the correct polarities as instructed Since the batteries are provided when shipped from the factory their lives may be shorter than brand new batteries due to
12. so may cause damage and deterioration in performance A new humidifying filter may smell at the beginning This is normal Replace the filter early if it is damaged N AUTION Washing the humidifying filter with citric acid will deteriorate the anti bacterial and anti mold performance Do not install the humidifying filter on the unit if containing too much water Doing so may cause water to leak E 23 T_S EP A6000 indd 19 z 2012 08 02 rl i Cleaning Continued Replacing Humidifying Filter The humidifying filter is a consumable part Replace it using 24 months of use as a guide cleaning is necessary on a monthly basis Early replacement of the filter is recommended if it exhibits any of the following conditions despite periodical cleaning e Heavy dirt adhered water scale that is too difficult to remove bad odors serious damage or deformation Depending on the quality of tap water used the humidifying filter may be consumed extremely early Detach the case and replace the humidifying filter Do not dispose of the humidifying filter case To detach the case push the tabs three locations Detach the case by opening it in lt gt directions Humidifying filter for replacement No EP DX40E 908 E The humidifying filter is flammable Dispose of the filter according to local regulations Water Tray Tray Cover Guide for cleaning Once a month Do not use any detergent a Remove th
13. 4hrs i Off timer 4 hours is set w How to set cancel Timer The timer indicator lights up Operation will stop approximately 4 hours after the timer is set Every time you press the O button Set and Cancel will alternate JE OUOD SJOWWSY BuIsN a E 17 ae 2012 08 02 re i Using the Control on Unit Press button w Operation starts 0 Every time you press the button the operation mode switches in the following sequence so that you can choose a desired mode or stop pir PPollen p Strong p Hmi gt Skin gt Off Deodorization Moisturize The airflow rate is set to Auto by switching the operation mode Memory Function Sensors Auto Detection Memory Function ph When you stop operation and then restart the purifier will resume the operation that was running before shutdown If you operate the Purifier for approximately 5 seconds or longer the operation status will be stored in memory If you stop operation before 5 seconds have elapsed the operation status will not be stored in memory Even if you unplug the power cord the operation status will be stored in memory However the airflow rate is automatically set to Auto Air Sensor Level of air contamination detected by the odor sensor and dust sensor is shown by the way the indicator is activated Indicator action Light up in green e g
14. E 32 T_S EP A6000 indd 9 z 2012 08 02 ok E 11 i Preparations for Operation Continued Humidifying filter Remove the water tray confirm the humidifying filter and tray cover are attached and press it back in place Water supplied from the water tank is sucked upward by the humidifying filter for humidification Set the water tank in the receiving portion of the body Push in the handle of the water tank firmly until it clicks and ensure it will not come off When it is difficult to push in the water tank move the handle up and down Insecure attachment may result in the water tank falling or water leakage CAUTION Please securely tighten the tank cap After tightening turn over the tank cap wipe off any spilt water and check that there is no water leakage If water leaks retighten the tank cap firmly and recheck whether any water leaks ae If water still leaks stop using the unit When carrying the water tank keep the tank cap side up Taa and hold the top and bottom of the water tank If the water tank is wet wipe off the drops before carrying When water collects in the handle of the water tank wipe it off Do not apply excessive force to the water tank for example holding the front and rear with hands placing something on it stepping on it or dropping it Do not freeze the water in the water tank Do not freeze the water in the water tank
15. Oil and dust accumulated inside the body may result in fire disaster failure and oe Do not use in a humid place such as in a bathroom It may cause an electric shock or unit failure Do not place the air purifier near a hot object such as a heater Doing so may cause unit failure or deformation Do not use in a location where soot from oil such as machine oil is floating in the air Doing so may cause a crack or fire Do not use the air purifier in a kitchen as a substitute for a ventilation Doing so may cause a unit failure Do not use in a location where any organic solvents or chemicals are used Doing so may cause discoloration deformation or fire Do not use the air purifier in a location where a machine tool that produces flammable dust or sparks such as a grinder or welder is installed Otherwise it may cause a fire Purifier and Panel Do not use benzene or thinner to clean the purifier or spray flammable gas such as insecticides Doing so may lead to cracking electric shock ignition or explosion Do not let any inflammable materials lit cigarettes or incense enter the air purifier intake Doing so may cause a fire Securely hold the grip when carrying the air purifier Dropping it may cause an injury or damage it Miscellaneous In case the unit becomes inoperative or anything abnormal such as smoke or unusual odor is noticed immediately unpl
16. Pollen Deodorization Humidify Moisturize Timer 4hrs Sensor On Off Max Blinking net Filter F Pressing button during operation will stop operation If the On Off button is not pressed after the power cord is plugged in all indicators will go off after the Air Sensor and Humidity Level 50 indicators blink for 3 minutes Operation via remote controller is accepted even in this state The factory setting is Air Purify From the second time onward the memory function enables the operation with memorized conditions gt PE 18 Stand by Power Consumption As long as the power plug remains inserted in the AC outlet approximately 4W power will be consumed even if the unit is not used Unplug the power cord when the unit will not be used for an extended period of time E 14 T_S EP A6000 indd 10 5 2012 08 02 oe Selecting Operation Mode Basics 5 operation modes are available In every operation mode the fan will not stop during operation In eco operation mode the fan may stop gt PE 21 In every operation mode the air purifying function will work When the operation mode is switched airflow rate is set to Auto Operation Modes and Tips for Selection Operation mode Tips for Selection Air Purify Green This is a normal operation mode The odor sensor and dust sensor detect the degree of air contamination and airflow rat
17. Wipe off any powder that is spilt or adheres to the filter The deodorization performance will be unaffected Setting Filter in Unit The procedures for filter replacement are also the same Use a genuine filter for the Hitachi Air Purifier ap Remove the panel and pre filter Place the body in a horizontal and stable place CAUTION D Hook your fingers at the bottom of the panel in two locations Do not rotate the knobs in slowly pull toward you and slightly shift upward to remove reverse or rotate them forcibly 3 Rotate the knobs of the pre filter in two locations to the left to Doing so may result in damage unlock 4 Remove the pre filter uolTesJEdO JO suogeredald OSA UO SUOIINeD g chy D L i ONDA Open and pull l ON NANN the pre filter to remove it from Remove the filter There is a dust filter and deodorizing filter Remove the filter packed in a plastic bag from inside the purifier Take the filter out of the plastic bag Remove the packaging Install the deodorizing filter on the purifier aN Sw XA 1 Install the deodorizing filter so that its black surface k Fi lack Se faces the front white surface in the back NS B D Insert the filter all the way until the label deodorizing filter position indicator is hidden Note Be sure to take the filter out of the plastic bag Do not block the front face of the filter with cloth or paper The same
18. e is switched automatically During the auto sensor operation airflow rate ranges from Silent to High Green This mode is recommended for users who are concerned about pollen contamination The odor sensor and dust sensor detect the air contamination level and the unit operates automatically In the automatic operation mode airflow rate will be Silent to Med Strong Deodorization Green This mode is recommended for users who are concerned about room odor The odor sensor and dust sensor detect the degree of air contamination and the unit switches to the operation with higher airflow than Air Purify mode During auto sensor operation airflow rate ranges from Low to Max In the first minute Max airflow operation is performed regardless of the level of air contamination Orange Room air humidity is controlled to approximately 50 During auto sensor operation airflow rate ranges from Silent to High Orange Room air humidity is controlled to approximately 60 During the automatic operation airflow rate ranges from Silent to High During operation vibrations from the unit may slightly rock the water in the water tank Mode Selected operation mode indicator lights up Strong Skin On se Pollen Deodorization Humidify Moisturize Timer 4hrs Press button IO ie Clean Max Blinking Humidifying Filter Sensor Setting O Operation mode switches every tim
19. e tray cover Wash with water to remove dirt Remove the tray cover from the water Drain water remaining on the try Use a cotton swab or toothbrush to remove dirt in narrow parts Wipe off water and assemble Attach the tray cover to the water tray ZANWARNING Do not use detergents for either kitchen or laundry use for cleaning XCAUTION When you mount the water tray on the unit the tray should be empty Otherwise water may spill out E 24 T_S EP A6000 indd 20 5 2012 08 02 pen Pre filter Guide for cleaning Once a month To clean the pre filter follow the steps below D Remove the water tank and then pull out the water tray This is to prevent water leakage ANG AUTION When you remove the tank water may drip from the tank cap Lay a dry cloth before removing the water tank Remove the panel and pre filter Clean the filters Pre filter Remove dust with a vacuum cleaner etc Lightly apply the nozzle brush of the vacuum cleaner and suck up the dust If heavily soiled do not apply strong force but wash with water using a commercially available soft sponge drain sufficiently and dry in the shade with a breeze i Pre filter Strongly rubbing with a floor nozzle of a vacuum NS Ena cleaner or a scourer will cause the stainless L coating on the surface to come off Do not use detergent for kitchen washing etc Nozzle with brus Dust col
20. e walls on both sides Otherwise discharged air will mix with surrounding air and the walls may become dirty Do not place the unit on an unstable floor or pedestal Otherwise the unit may fall or drop resulting in damage or unit failure Using the unit positioned on an angle may cause water to leak Opening the flap Hold the tip of the flap with your hand and adjust it The angle of the flap is adjustable in three stages When in operation use it in a diagonal or upward direction uoleyyejsu uogeiado JO suoneedald i Position of the flap Closed when not in operation Diagonal direction in pollen mode Upward direction se Wind direction Wind direction ma Flap N ey t j ve When not in operation close the Incline the airflow by the flap to Normally use in the flap to avoid dust ingress improve the capture efficiency upward direction When in operation set it in a of pollen floating near the floor diagonal or upward direction Use in pollen mode When changing the angle of the flap move it until it clicks Do not operate with the flap closed Doing so may result in louder noise and greater vibration or failure Do not apply excessive force to the flap Doing so may result in failure and damage N CAUTION Do not move the body by holding the flap Damaging or dropping the unit may result in unexpected injury E 13 T_S EP A6000 indd 10 2012 08 02
21. e you press the Mode button Operation mode To j i Air Purify gt PO EN mama Sy DZ a gt Huif a gt Skin Moisturize switches every time you press this button HITACHI EPR 35 The airflow rate is set to Auto by switching the operation mode T_S EP A6000 indd 11 J9 OIUOD SJOWWSeY Huis B E 15 2012 08 02 a Using Remote Controller Continued Airflow rate When Auto is lit the following airflow rate is used according to the selected operation mode The airflow rate indicators from Silent to Max do not light up Mode Airflow Range Air Purify Silent 4p Low 4 Medium lt gt High Pollen Silent 4 gt Low lt gt Medium Strong Deodorization Low lt gt Medium lt gt High lt gt Max Humidify When humidity level indicates 60 or higher o Silent gt Low lt gt Medium lt gt High Skin Moisturize When humidity level indicates 70 or higher E a a a a Silent gt Low P Medium gt High According to the level of air contamination and humidity detected by the odor sensor dust sensor and humidity sensor airflow rate is automatically switched to an appropriate level So far as the water tank and water tray are filled with water humidifying function works in any of Air Purify Pollen and Strong Deodorization modes If you do not want the humidifying function drain the wa
22. ean the odor sensor gt P E 26 Clean the dust sensor Clean the odor sensor gt P E 26 2012 08 02 a m 1 8 apind Bunooyssiqna Aeldsig vey jUewece dey Jeyl4 a Troubleshooting Guide Continued Symptom Check to see Air Sensor indicator is kept blinking in green No humidifying effect Humidifying performance is inadequate when operated in Humidify mode When operated in Air Purify Pollen or Strong Deodorization mode air is humidified Water leaks Indicator is dim The Clean Humidifying Filter indicator does not go off E 30 i T_S EP A6000 indd 26 ls there anything nearby that the odor sensor might detect e Any appliance generating combustion gas e Alcohol cosmetics sprays etc Is the odor sensor hole blocked by dust or other obstacles Is there water in the water tank s the operation in any of Air Purify Pollen or Strong Deodorization mode Is the humidifying filter dirty ls the airflow rate set to Auto Is the pre filter or the filter dirty Is the humidifying filter set properly or is it dirty ls there water in the water tank and water tray Is the humidifying filter wet with water Is the water tank set correctly Is the tank cap closed firmly or is the tank cap packing set securely ls the water tray cover closed properly Is the humidif
23. er Te gt WE Ger 2 28 Air Sensor Brier ime Set wer Sat wer E Goh seh er ate er aie eras ter ere Odor Sensor ees E We WW We Set ce Wy e e e Sew tos panies er A Dust sensor Auto Detection eo 6 oe ew ew wh ee ew ew o Adjusting Sensor Sensitivity Setting Useful Feature lt ss eect eee Eco Operation ee We Sat Ter Ser ee a ct Gay sas a fer ibe er fe Dimmer Control BP ree We er eaea See Gee as o O Wy He Cleaning and Maintenance Cleaning ee When the Clean Humidifying Filter Indicator Comes On Water Tank Humidifying Filter Replacing Humidifying Filter Water Tray Tray Covers ssc ccc ttc Pre filter Ce Unit Dust sensor eeeeseeseeeeee Filter Replacement 555r rererere Replacement Interval Precautions regarding Filter Handling Replacing the Filter scr cette tee Alert Display terre trees Troubleshooting Guide Replacement Parts Specifications SAR MRS SUR he Bo ee 2012 08 02 i i Features Name of Each Component Accessories DIRAO gt P E 19 The dust sensor is capable of sensing dust in the air such as cigarette smoke house dust pollen etc Deodorizing filter Nano power deodorizing filter EASA gt P E 19 Set this filter at the back s humidit of the purifier enS NUMISIIY Filter assembly Rem
24. er tray and tray cover gt P E 23 E 24 When the unit is shaken or rocked water may gather in a part other than that where the humidifying filter of the water tray is installed After you pull out the water tray be sure to remove the tray cover and wipe off any water that exists or clean it Humidifying filter Set the humidifying filter Slowly insert the humidifying filter into the tray cover Insert the filter fully until it comes into positive contact with the bottom of the tray Inadequate fitting may cause water to leak during operation Install the water tray and then mount the water tank Plug the power cord into the AC outlet and press the reset button located behind the panel J Use the tip of a ball point pen or similar object Check that the Clean indicator is now OFF Mount the panel on the purifier E 22 i T_S EP A6000 indd 18 5 2012 08 02 oe Water Tank Guide for cleaning Daily Change water daily with fresh tap water Discard any remaining water in the tank Pour a small quantity of tap water tighten the cap firmly and shake to wash Change water and repeat the steps twice or three times ZAN WARNING Do not use detergents for either kitchen or laundry use for cleaning Do not push in the pin at the center of the cap Doing so may cause water to leak N AUTION Be sure to stop operation before removing the water tank from the u
25. gh the humidification function was not used D gt When the eco operation is selected the fan may stop gt P E 21 When the power plug has been inserted gt into the AC outlet for about 1 month about 720 hours the lamp lights up gt P E 22 Replacement Parts Separately Available Dust Filter Designate the replacement part No EP A6000 902 when ordering Pre filter Designate the replacement part No EP JV1000 002 when ordering Tank Cap Designate the replacement part No EP JV700 005 when ordering Deodorizing filter ies Designate the replacement part i i No EP A6000 903 when ordering uh Humidifying Filter Designate the replacement part No EP DX40E 908 when ordering zane The case is not included Specifications Power supply Airflow switching EP A8000 AC220 240V 50 60HZz i 4 Applicable floor space Airflow rate m min Humidifying performance mL h Length of power cord Approx 1 8m E 32 T_S EP A6000 indd 28 4 55m Approx 670 Max operation 584 H x 430 W x 268 D mm 2012 08 02 baa
26. he optional EP A6000 902 dust filter and EP A6000 903 deodorizing filter AX CAUTION Use a genuine filter for the Hitachi Air Purifier Other filters may cause unit failure W Before replacing the filter be sure to stop the purifier and unplug the power cord from the AC outlet Remove the water tank and then pull out the water tray This is to prevent water leakage AX CAUTION When you remove the water tank water may drip from the tank cap Lay a dry cloth before removing the water tank Remove the panel and the pre filter Remove the used filter Remove the dust filter and then the deodorizing filter Deodorizing filter Take a new deodorizing filter out of its plastic bag and install it on the purifier D install the deodorizing filter so that its black R Z3 l surface faces the front white surface in the back insert the filter all the way until the label deodorizing filter position indicator is hidden Z CAUTION Be sure to take the filter out of the plastic bag Do not block the front face of the filter with cloth or paper Deodorizing filter The same precautions should also be Black surface followed for the dust filter bag and install it on the purifier gt P E 9 Insert the filter all the way until the label dust filter position indicator is hidden Install the pre filter on the purifier O Take a new dust filter out of its plastic Dust filter Deodorizing f
27. he water tank and water tray os Remaining water can be a cause of dirt or discoloration wane Do not disassemble the humidifying filter from its case Submerge the Change the water humidifying filter in either and rinse the water lukewarm water or humidifying filter by water containing neutral shaking it kitchen detergent for Repeat the steps 30 minutes or longer 2 or 3 times Do not disassemble the humidifying filter from its case When you use neutral kitchen the instructions provided by the manufacturer Only use neutral kitchen detergent Shake lightly to drain off water Continue until no more dripping occurs no detergent remains Bulueajo J As you operate the unit whitish or brownish water scale will adhere to the inside of the water tray or to the surface of the humidifying filter Water scale is residue minerals from tap water that have not evaporated If you continue to use the filter without cleaning the water scale it will solidify and become difficult to remove resulting in lower humidifying performance Depending on the quality of tap water used water scale may adhere quickly In such a case clean the filter on a frequent basis When you rinse the humidifying filter rinse it as assembled with its case Do not remove the case Removing the case may cause deformation or damage Do not scrub the humidifying filter with a brush or press forcibly to deform Doing
28. ifying operations the unit will not pause at a certain humidity level Normal automatic operation z When the air is clean the unit continuously operates Silent using Silent airflow In the strong deodorization operation mode the airflow rate is set to Low Stop Eco operation When the air is clean and the Silent operation 10 minutes 10 minutes 10 minutes continues for 10 minutes or longer the fan stops for about 50 minutes and the unit intermittently operates Silent using Silent airflow for about 10 minutes operation If this state continues for longer than 8 hours the unit Stop automatically stops operation 50 minutes 50 minutes The degree of air contamination is detected by the odor sensor and dust sensor during eco operation If the sensors detect odor or dust the airflow rate switches according to the degree of air contamination When the air becomes clearer and the unit runs for 10 consecutive minutes or longer using Silent airflow the unit starts intermittent operation el O O Press O button eco indicator lights up Strong Skin d Air Purify Pollen Deodorization Humidify Moisturize Max Blinking Auto ah o How to set cancel ACEI Every time you press the O button Set and EPR 35 Cancel will alternate The settings are stored Man Sensor The mode is set to the eco operation Setting chy P
29. ilter O Reinstall the panel on the purifier A Install the water tray and then mount the water tank NACA No cleaning effect can be expected if the filter is inserted while still inside the plastic bag This may also cause a malfunction E 28 i T_S EP A6000 indd 24 z 2012 08 02 a Alert Display All airflow indicators are blinking Faulty fan rotation Stop the operation unplug the power cord from the AC outlet and contact your dealer for service Troubleshooting Guide Before asking for repair Symptom Check to see No air blows out or no power is supplied Smoke or smells are not efficiently removed or there is an odor No remote operation Airflow rate does not decrease even though the air is clean Airflow rate does not increase even though the air is contaminated Air Sensor indicator remains constantly lit in green Air Sensor indicator is kept blinking in green T_S EP A6000 indd 25 ls power plug securely inserted into the AC outlet Is the breaker switched off Is the pre filter very dirty Is the filter dirty Are battery polarities correct Are batteries dead ls the remote infrared receiver dirty Has airflow rate been switched Is the operation in the Humidify mode Is sensor sensitivity high Has airflow rate been switched Is the odor sensor
30. ion mode Deodorization Low lt Moderate High Indicator Green Orange Orange Green Orange Orange E EE EE E e Humidify Skin Moisturize PEISA F Db Indicator Orange The indicator lights up or flashes bd hd G green to indicate the air condition 30 40 50 60 70 detected by the dust odor sensor o o oo oo op Humidity Level 30 40 50 60 70 Approx Strong _ Skin Air Air Purify Pollen Deodorization Humidify Moisturize Timer 4hrs Sensor o eer Clean Max Blinking Humidifying Filter o Airflow Level gt P E 16 Clean Humidifying Infrared Remote Receiver These indicators green indicate the airflow rate during operation ARG gt P E 22 Receives the signal from Auto Airflow rate during auto operation oo the remote controller This indicator red Indicates eco operation is active indicates that itis These indicators show the airflow rate time to clean the lected using the airflow button on th oe ee humidifying filter Timer gt P E 17 Silent This indicator green Med lights up when the 4 hour Strong or Max blinking timer is set chy Remote Controller When using the remote controller point it at the infrared remote receiver on the unit indicator section gga When aimed squarely at the infrared remote receiver the remote controller can be used at eC gt P E 16 distances of up to approximately 6 m Press this button to switch Ooa sition gt
31. l remove the stain using a soft brush ys E For stains on the body wring a soft cloth soaked with water dry and wipe Odor sensor If the unit is significantly soiled soak a soft cloth in dilute neutral kitchen detergent with water and wipe After removing the stain wipe off sufficiently so that no detergent remains E When oil or chemicals such as insecticide etc is attached clean out on each occasion E For dust etc attached to the surface of the flap wipe it off with soft cloth E For stains on the remote light receiver wipe with a narrow cotton swab soaked with a little water and subsequently wipe with a dry cotton swab Do not use anything other than neutral kitchen detergent A N C AUTI O N Otherwise cracking discoloration damage or scratches to the panel surface may be caused Dust sensor Cleaning guide every 3 6 months Carry out periodical cleaning every 3 6 months Otherwise the performance of the dust sensor will drop aD Remove the dust sensor cover 2 Wipe the lens with a cotton swab Soak a cotton swab with a little water and use it to wipe off any heavy dirt After cleaning the dust sensor reinstall the dust sensor cover Dust sensor cover Do not wipe the lens forcibly Doing so may cause damage Z N CAUTION Do not forcibly disengage and engage the tabs of the dust sensor cover Doing so may cause damage E 26 T_S EP A6000 indd 22 5 2012 08 02 paa
32. lace the filter earlier than suggested Otherwise the filter may generate odors WiThe filter should be replaced earlier in the following cases e When the purifier intakes oily smoke carbon substances soot etc or when the smell of new building materials remains after a new house has been built or the house has been remodeled e When used in stores such as in coffee shops game parlors barber shops beauty parlors or in offices or hotels and inns e When the purifier intakes large amounts of cigarette smoke e When the purifier intakes combustion gases generated by heating appliances p e When the purifier intakes solvent content of paint adhesive etc gt e When used in dusty locations near roads subject to heavy traffic Precautions regarding Filter Handling HBe sure to take the filter out of the plastic bag before use e Do not set the filter when it is still in a plastic bag Otherwise a malfunction may occur HE Avoid handling it roughly e Do not crush knead or roll the filter Once the filter is broken it will not have any cleaning effect HiDo not wash the filter e The filter is not washable for reuse Purchase a new filter for replacement ithe filter contains plastics Dispose of the filter according to local regulations uswsoejdsy 1944 Bulueajo E E 27 i T_S EP A6000 indd 23 z 2012 08 02 sead i Filter Replacement Continued Replacing the Filter H For the filters use t
33. lection deodorization filter f you are concerned about dust on the Dust collection filter deodorization and dust collection filters Do not wash in water remove it with a vacuum cleaner and so on a Lightly apply the nozzle brush of the vacuum ieee st le cleaner and suck up the dust Nozzle with brush Attach the deodorization and dust collection filters Bulues D Attach the pre filter and panel to the body Install the water tray and then mount the water tank gt P E 12 The pre filter is a consumable part When pre filter needs to be replaced due to damage purchase the replacement part Part No EP JV1000 002 E 25 T_S EP A6000 indd 21 z 2012 08 02 ml i Cleaning Continued Unit Guide for cleaning Once a month E For dust etc attached to the back of the panel the odor sensor part Dust sensor the dust sensor part the humidity sensor part and the surface of the Humidity sensor remote light receiver suck it up with the nozzle brush of a vacuum cleaner and wipe with a soft cloth E When wiping the surface of the panel use a soft and clean cloth Since the panel is transparent wiping with a hard or soiled cloth may result in damage If the stain remains soak a soft cloth in dilute neutral kitchen detergent with water and wipe After removing the stain wipe off sufficiently so that no detergent remains E if it is difficult to remove the stain from the back of the pane
34. lure If the space between the unit and floor remains humid mold may grow on the floor If the unit is used at an angle water may leak out Do not drag the unit on any floor susceptible to scratches or on thick carpet Doing so may damage the floor or carpet surface Do not run with filter detached No cleaning effect can be expected unless the filter is used Running without the filter may lt also cause unit failure Heat oily smoke etc may result in deformation and discoloration Place at a distance of at least 1 m Do not block or touch the infrared receiver odor sensor dust sensor or humidity sensor Doing so may result in the infrared PN receiver becoming stained or damaged which may reduce its sensitivity The sensitivity of sensors may be reduced Do not install in a location where the air from the unit will blow directly onto furniture electric appliances walls or ceiling Humid air may cause stains or deformation of furniture or may cause unit failure Ventilate closed rooms occasionally The purifier does not have a ventilation effect The purifier cannot remove hazardous substance in cigarettes carbon monoxide etc E 8 T_S EP A6000 indd 7 Do not directly fan animals and plants Air drafts may adversely affect them Do not place anything on the unit and do not block the air inlet or x air outlet Doing so may cause
35. mbient temperature changes and may cause water to leak or injury due to deformation or damage Use a genuine filter for the Hitachi Air Purifier Other filters may cause unit failure Do not operate the unit when usingfumigating smoking type insecticide Use of such insecticides will cause chemicalsto accumulate in the unit and subsequently be emitted by subsequent operations which can be harmful to your heath After using insecticide ventilate the room well before running the purifier Do not allow water to freeze Doing so may damage the water tank causing a risk of electric shock and unit failure Whenever it is considered that water may freeze drain the water tank and water tray Do not use the purifier if water is leaking from it Doing so may cause an electric shock If water is leaking out unplug the power cord from the AC outlet and request repairs Do not carry the unit when the water tank is full Doing so may cause water to leak or injury If you carry the purifier when the water tank is full the level of water in the tray will rise and cause the water to overflow when operated Drain the water tank and water tray first and set them on the unit before carrying Do not tip over or drop the water tank when it is filled Doing so may cause an injury or the tank to become deformed or damaged Hold the tank securely when you fill it with water Do not look into the indicator Doing so may cause an eye inj
36. n using a chemically treated cloth follow relevant instructions AN AUTION Never use a dryer or heater to dry the unit case Heating could cause deformation discoloration damage or removal of prints Lay a soft cloth or similar material beneath the unit to protect the floor against scratches m When the Clean Humidifying Filter indicator lights up clean the humidifying filter water tray and tray cover The Clean Humidifying Filter indicator will come on approximately one month approximately 720 hours after the start of use or after the reset button was pressed after the previous cleaning operation finished Depending on the tap water used water scale may adhere earlier If there is heavy filter contamination clean the filter more than once a month before the Clean Humidifying Filter indicator lights up E After cleaning press the reset button The Clean Humidifying Filter indicator will go off When the Clean Humidifying Filter Indicator Comes On Remove the water tank and then Remove the humidifying filter from pull out the water tray the water tray R Water tray iI SZ Humidifying filter NS Slowly pull out the water tray while lifting it upward at an angle N AUTION When you pull out the water tray from the unit water may spill out or the floor may be scratched by the tray bottom Lay a soft cloth or similar material beneath the unit to protect the floor Clean the humidifying filter wat
37. nit Do not set the water tank without first setting the water tray in place Otherwise the water tank may tip over When you remove the water tank water may drip from the tank cap Humidifying Filter Guide for cleaning Once a month The humidifying system employed in this product is the evaporating type that produces moisturized air by passing an air stream through the humidifying filter Depending on the application environment dirt or odor may adhere to the humidifying filter even when the Humidify or Skin Moisturize mode is not activated When Humidify or Skin Moisturize mode is used be sure to pour tap water into the water tank Although the humidifying filter has been treated against bacteria and mold it may get slimy or moldy or may become discolored to pink red green brown or gray after a short period of use depending on the quality of tap water used and the application environment Discoloration has no effect on humidifying performance It is recommended that the filter be cleaned as often as practicable regardless of whether the Clean Humidifying Filter indicator lights up or not Early replacement of the filter is recommended if it exhibits any of the following conditions despite periodical cleaning Heavy dirt is present adhered water scale is difficult to remove bad odors serious damage or deformation If you do not use the Humidify or Skin Moisturize mode drain t
38. ote controller Allergen free HEPA filter Set this filter to the front side of the purifier Pre filter Stainless pre filter Removes large dust particles Unit indicator section gt P E 3 p Panel Air outlet Stainless net Shutter air inlet Hand grip When carrying be sure to hold the handles Ole lolay atelan gt P E 18 Senses odors in the air Flap Stainless flap Air inlet around the panel No air inlet on the panel front face Do not move the body by holding the flap Damaging or dropping the unit may result in unexpected injury Filter AAA R03 Humidifying filter Housed inside batteries for the purifier D remote controller Be sure to remove this filter from the plastic bag before dust filter x1 fe Q operating the purifier deodorizing filter x1 f E 2 i T_S EP A6000 indd 2 5 2012 08 02 psa i Operation Buttons and Indicators E P shows a page in the instruction manual with additional information Unit Operation Buttons and Indicators Humidity Level Operation Mode On Off Button Indicates approximate humidity level in Shows the operation mode Press this button to start or stop opera the room during operation e Air Purify Pollen Strong tion and to switch the operat
39. ply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Do not use with a voltage other than 220 240V AC Otherwise it may cause a fire or electric shock Do not damage the power cord Do not break modify forcibly bend pull or twist it Also do not place any heavy objects on it or pinch it Otherwise it may cause a fire or electric shock Do not use a damaged power cord or power plug or a loose AC outlet Otherwise it may cause an electric shock short Circuit or ignition E 4 T_S EP A6000 indd 4 5 2012 08 02 pa i Water Tank Water Tray and Humidifying Filter Do not operate the unit without first setting the water tank water tray and humidifying filter in place Otherwise it may cause an injury or unit failure Do not use any detergent used for kitchen or laundry when cleaning the water tank or water tray Ingredients in the detergent may cause damage and subsequent water leakage or electric shock injury or unit failure Do not carry the water tank by its handle Dropping the tank may inadvertently cause an injury or other accident Do not disassemble the tank cap Otherwise it may inadvertently cause an accident such as small children swallowing it by mistake Tank cap Place of Use Do not use in any place with considerable oily smoke such as a dining room restaurant kitchen etc
40. r is clean If the sensitivity of the sensor remains low after doing so change the sensor sensitivity setting E 19 uonosieq olny S Osues oyun Howay yun UO JOuJUOD y Buisn B i T_S EP A6000 indd 15 z 2012 08 02 veal lt b i Memory Function Sensors Auto Detection Continued Adjusting Sensor Sensitivity Setting Sensor sensitivity can be adjusted in 3 step fashion In each operation mode On Off Mode Airflow Sensor Setting a press button i r Use the tip of a ball point pen or Sensor similar object Setting e The airflow indicator will blink for 5 seconds While the airflow indicator is blinking Sensor Setting press o button The factory setting is Medium E 20 T_S EP A6000 indd 16 5 Present setting is shown by the airflow indicator that blinks for 5 seconds Strong Skin Air Purify Pollen Deodorization Humidify Moisturize Max Blinking Auto eco aa Aa Yoru 0 gt aba bys Every time you press the button the setting switches pad v v lt I gt abdi 2 Medium 2012 08 02 eal i Useful Feature in the eco operation mode the unit automatically pauses when the air in the room is clean in order to save money on electricity Furthermore if this state continues for longer than 8 hours the unit automatically stops operation During humid
41. s the unit employs an evaporation system that produces moisturized air by passing an air stream through the humidifying filter no vapor or mist is visible This is normal No vapor or mist visible Humidity level is indicated as a guide only Also differences in the environment in different parts of the room may cause different indications Humidity level indication differs from hygrometer reading Performance is not affected even if the shutter is not fully opened This is normal Shutter is stopped midway This is caused by vibration during Water surface in the water tank waves Sporan hE E hanal The unit is in demo mode Unplug the power cord once wait for a few seconds and then insert the power plug into the Unit indicators repeatedly turn on and off one after another and the fan is stationary v VV V V aping Buljooysejqnol a AC outlet Pressing the eco button operates the ionization setting release of the other Hitachi air purifier with ionizing function Because the signals from the remote Pressing the ionizing button on the remote p controllers are the same both functions controller for the other Hitachi air purifier with eemeli S Csin ionizing function operates the setting release of eco operation E 31 i T_S EP A6000 indd 27 z 2012 08 02 all Troubleshooting Guide Continued Operation other The fan is stopped The humidifying filter clean lamp lights up althou
42. self discharge Press in the cover until Batteries are consumable items it clicks When replacing batteries replace two batteries simultaneously Only use two manganese batteries or two alkali batteries Do not mix different types of batteries Quietly remove the water tank As in the following illustration Pull the water tank toward you and remove it applying your thumb to the top of the water tank handle lift up the bottom to unlock N CAUTION When removing the water tank water adhering to the tank cap may spill so lay a dry cloth beforehand uolyes9do JO suoneJedald a Remove the tank cap and fill Rubber packing with clean tap water at room N Ensure the rubber packing is installed to the tank cap temperature When pressing the pin in the center of l the pin in the the tank cap confirm it returns with a spring center of the Firmly fix the tank cap parallel to the surface Z tank cap of the water tank inlet Wipe off the spilt water Va Doing so may and turn the tank cap upside down to check w SZ result in water that there is no water leakage leakage When carrying the tank keep the tank cap upward When water collects in the handle of the water Do not press in tank wipe it off The tank cap is consumable When water leaks due to deterioration etc of the rubber packing purchase the tank cap a part separately sold to replace gt P
43. t Blink in green Contamination level Clean gt Contaminated Mmoktrize OTimer 4hr Note j Max Blinkino apes You can adjust the air sensor and dust sensor sensitivity setting as desired P E 20 Filter T in case the purifier is installed in a location where air contamination is difficult to detect or in case the sensor itself is not clean the indicator action may not change P E 29 Odor Sensor The sensor detects odors in the air such as cigarette smoke or animal odors Even if you think the air is clean the unit may continue the operation if the odor sensor detects any gas component that has not been removed by the filter Any of the following may also be detected by the odor sensor Combustion gases from heating appliances alcohol odor of perfumes or cos metics used in beauty parlors or aesthetic salons sprays vapors abrupt tem Ie Rk perature changes etc Odor sensor E 18 T_S EP A6000 indd 14 5 2012 08 02 i Dust sensor The dust sensor is capable of sensing dust in the air such as cigarette smoke house dust pollen etc The dust sensor may fail to sense dust stirred up when you lay out or put away bed ding which contains significantly fewer contaminants than cigarette smoke etc In such acase the displayed air contamination level may appear to be lower Carry out periodical cleaning every 3 6 months Otherwise the performance of the dust sensor will drop P E 26 D
44. ter tank water tray and humidifying filter Switching Airflow Rate You can select a desired airflow rate from the four different levels On Off Mode Max HITACHI EPR 35 E 16 T_S EP A6000 indd 12 Airflow Press button D Airflow rate switches every time you press this button Sensor Settin O g Airflow rate indicator comes on Strong Skin e Air Purify Pollen Deodorization Humidify Moisturize OTimer 4hrs A Clean D Max Blinking Humidifying Auto eco Filter Oo Airflow rate changes in the following sequence Auto p gt gt gt Silent Medium High Blinking Max 2012 08 02 Peni Max Operation Air Purify Mode This operation is useful in an environment where many people are smoking or when you want to clean room air quickly On Off Mode HITACHI EPR 35 Airflow Max The airflow indicator blinks for 5 minutes Press O button D d Auto gz Filter The operation with Max airflow will continue for about 5 minutes a After the Max operation the status On Off Max before the Max operation is resumed Press O button or O button during operation ay Clean Max Blinking Humidifying it takes about 10 seconds until the air flow rate reaches Max On Off Mode HITACHI EPR 35 T_S EP A6000 indd 13 Airflow Timer St Ski Press O button Pollen Eoo Humidify Meurz Timer
45. tes the AN WARNING possibility of death or serious injury Indicates warning or caution This symbol indicates the S Indicates prohibition ZN CAUTION possibility of injury or damage to property cD Indicates a must N WARNING To Prevent Fire Electric Shock and Injury AC Outlet Power Plug and Power Cord Before cleaning and carrying out other types of maintenance be sure to unplug the power cord from the AC outlet and never pull it out or insert it with wet hands Otherwise it may cause an electric shock or injury gt Be sure to hold the plug not the power cord gt Panel 7 when unplugging it from the AC outlet p 4 ane Purifier Otherwise it may cause an electric shock or short J CDS circuit which may result in a fire Be sure to unplug the power cord from the AC outlet when not using the air purifier for an extended period of time Also drain the water tank and water tray Otherwise it may cause an electric shock fire or create unpleasant odors Securely insert the power plug into the AC outlet Otherwise it may cause an electric shock fire smoke emission and ignition Remove dust from the power plug periodically using a dry cloth Otherwise it may cause a fire If you notice any abnormalities water leakage burning smell etc stop operation and unplug the power cord It may cause an electric shock or fire due to ground leakage or short circuiting if the sup
46. ug the power cord to prevent an Q accident and contact your dealer to request checking or repair It may cause an electric shock or fire due to ground leakage or short circuiting Ventilate the room on a frequent basis if any heating appliance is simultaneously used with the air purifier Otherwise it may cause carbon monoxide poisoning The appliance is not to be used by children or people with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction Children should be supervised to ensure that they do not play with the appliance S Never attempt to disassemble modify or carry out repairs by yourself Doing so may cause a fire electric shock or injury Contact your dealer for repairs Do not put your finger or any other object into the air outlet or inlet Otherwise it may cause an injury or unit failure Do not submerge or splash water on the unit Also avoid filling water directly into the unit Doing so may cause an electric shock or short circuit Do not tilt or tip the unit over Do not put your weight on the unit or step on it Doing so may cause the unit to tip over which may cause an injury or water leakage Do not install it in an unstable place or anywhere near infants Doing so may cause the unit to tip over which may cause an injury T_S EP A6000 indd 5 z 2012 08 02 ore suolnedaid JLS i E 5 i
47. ury E 6 T_S EP A6000 indd 6 5 2012 08 02 Peni i Miscellaneous Do not use near cooking utensils Heat oily smoke etc may result in component deterioration electric shock and ignition Do not strongly push or pull the flap Doing so may result in injury and failure Do not move the body by holding the flap Damaging or dropping the unit may result in unexpected injury When using near a pet do not let it urinate on the body or bite the electrical cord Doing so may result in electric shock and ignition In such a case disconnect the power plug from AC outlet and request repair To Prevent Floor Scratches or Wall Stains During Cleaning Place of Use During cleaning lay a soft cloth on the floor and place the unit and detached components panel water tank water tray etc on it Otherwise it may cause scratches onthe floor When you pull out the water tray from the unit be careful not to scratch the floor with the bottom of the tray cloth covered wall The air purifier will take in the surrounding air and may produce stains on a wall near its air P outlet F S Do not use the air purifier near a wall that cannot be scrubbed such as a white E 7 i T_S EP A6000 indd 6 z 2012 08 02 ore Cautions on Use Do not install in an unstable or angled location or near any obstacles Otherwise the unit may fall or drop resulting in damage or unit fai
48. ust Sensor Humidity Sensor The humidity sensor detects humidity of room air during operation Humidity levels should be taken as a guide only The indication may differ from hygrometer readings e Humidity will change as temperature changes e Humidity levels may differ between well ventilated and poorly ventilated places Humidity Sensor Auto Detection The air purifier performs automatic operation by detecting room air contamination using the Odor Sensor and Dust Sensor and room air humidity using the Humidity Sensor During the first 3 minutes after the power cord is plugged in the unit will check the air condition of the room and save it in memory During this time the Air Sensor and Humidity Level 50 indicators will blink After 3 minutes both the Air Sensor and Humidity Level 50 indicators will go off and the purifier will now be ready to operate You may start the operation within 3 minutes after the power cord is plugged in In this case too the Air Sensor and Humidity Level 50 indicators will continue to blink meaning the unit is checking room air condition After 3 minutes have elapsed the indicators will stop blinking if you plug in the power cord in an environment containing contaminated air the sensitivity of the sensor may be reduced In such a case perform the High or Max operation Or open a window and plug the power cord into the AC outlet when ambient ai
49. ying filter set securely Is the unit tilted or was it carried with water in the tank ls there any opening in the water tank or water tray Is there any leakage from the water tank Has the dimmer control been activated Was the reset button pressed after cleaning v v vvv Vv vTvvvvvvvv V V V V The Purifier may detect components of invisible gas that cannot be cleaned by the filter and continue operation Ventilate the room by opening windows etc gt P E 19 gt P E 26 gt P E 12 Clean the odor sensor Fill the water tank with water Change the operation mode to Humidify or Skin Moisturize mode gt P E 15 Clean or replace the humidifying filter referring to the Humidifying Filter in Cleaning gt P E 23 Depending on the installation location and conditions of use water may not be consumed Set the operation mode to Skin Moisturize and the airflow rate to High or Max gt P E 15 E 16 Clean the pre filter referring to the Pre filter in Cleaning gt P E 25 Set the humidifying filter correctly If it is dirty clean or replace it gt P E 22 E 24 Discharge water and then operate Drain the humidifying filter Set the water tank correctly gt P E 12 Close the tank cap firmly gt P E 11 Close the water tray cover correctly Set the humidifying filter securely gt P E 22 Place the unit on

Download Pdf Manuals

image

Related Search

Related Contents

T'nB CTVN5 signal cable  Système de vidéo de recul avec moniteur de 5 pouces et caméra RV  取扱説明書  F18 manual(ENG) NO FM.cdr - Pdfstream.manualsonline.com  11-08-01 HP用MSSG要約.docx - Aki  Manual del propietario - Hearth & Home Technologies  Guía del usuario - Utilizando Fedora 11 para realizar tareas  Panasonic WV-Q155CE  Cisco Systems SA-ISA User's Manual  PYLE Audio PSWLE81 User's Manual  