1. RJ 45 Jack 100FX Fiber Fiber Optic Network il a e Cat 5 Cable PD Device Refer to Fig 6 Fig 2 Connection among PSE Ethernet Switch Fiber and TP Cables 100FX Fiber Network TX Fig 3 PSE to PD or PoE Splitter 3 PSE 10 100Base TX to 100Base FX Media Converter One n Poe Power Sourcing Equipment 802 3af Endpoint Lt Fig 4 PoE PSE Media Converter Front Panel AC Line 100 240V 50 60Hz u This device complies with Part 15 FRE y NN ofthe FCC Rules gt mn MADE IN TAIWAN Fig 5 PoE PSE Media Converter Rear Panel Fig 6 Endpoint PSE RJ 45 Male Connector 4 Note TEEE802 3af assigns pairs on the RJ 45 connector and Cat 5 cable of Endpoint PSE Endpoint 48V via TP pin 1 2 3 6 5 WDM Single Fiber Model The TP Fiber converter is specially designed with an optic Wavelength Division Multiplexing WDM model that can transport bi directional full duplex signal over a single fiber simultaneously 1310nm Single Mode 20Km TX Transmit 1310nm 40 60Km models are option RX Receive 1550nm 1550nm Single Mode 20Km TX Transmit 1550nm 40 60Km models are option RX Receive 1310nm Note The 1310nm and 1550nm models must be installed in pairs i e install 1310nm model at one end and 1550nm model at the other one PSE 10 100Base TX to 100Base FX Media Converter Ouma Quer YOu
2. User s Manual PoE PSE Power Sourcing Equipment Bridge Media Converter Fast Ethernet 10 100Base TX RJ 45 To 100Base FX ST SC LC PoE PSE Bridge Media Converter User s Manual Release 2 0 Part Number 620 1031 000 Release Date May 2005 1 Overview IEEE802 3u 100Mbps Fast Ethernet supports two types of media 10 100Base TX and 100Base FX for network connection LFP Link Fault Pass Through feature enhances the TP Fiber Link integrity and conformity Either one of TP or Fiber port is in link fail state the LFP converter forces the other port to be at link disabled state The PSE media converter complies with IEEE 802 3af its advanced auto sensing algorithm enables providing power devices PD discovery classification current limit and other necessary functions It also supports high safety with short circuit protection and power out auto detection to PD 2 Model Description Model Power Description PoE PSE TP Fiber AC Line 100 240V 50 60Hz The 100Mbps Fiber Transceiver Wavelength ST SC LC multi mode 2Km 1310nm SC LC S05 S20 S40 S60Km single mode 1310nm SC LC S80 S100Km single mode 1550nm Any other fiber model such as MT RJ is available upon request Single Fiber Model TX RX Wavelength 1310nm Single Mode 20Km TX Transmit 1310nm 40 60Km models are option RX Receive 1550nm 1550nm Single Mode 20Km TX Transmit 1550nm 40 60Km models are option RX R
3. 10 FDX or HDX Converter Fiber Port 100FX 100Mbps duplex selectable Bit 5 of S1 a FDX for 100FDX fiber link partner default b HDX for 100HDX fiber link partner RESET LEP TP AUTO 100 FDX EN FDX FX PoE s TP FORCE 10 HDX ajajajlejeja LFP HDX FX PoE DIS DIS Fig 12 Reset button and SI Bit 1 2 3 4 5 6 Configuration and Setting 8 Reset Once S1 1 S1 2 S1 3 S1 4 or S1 5 is changed please press this button to have the setting taken effect S1 1 TP port mode AUTO default or FORCE S1 2 TP port speed 100 or 10 when TP at Force S1 3 TP port duplex FDX or HDX when TP at Force S1 4 LFP f LFP enabled default or disabled S1 5 Fiber port duplex 100FDX default or 100HDX S1 6 PoE ON OFF Enable default or disable Note 1 S1 2 and S1 3 will take effect only when S1 1 is set at TP FORCE 2 S1 5 must be set to 100FDX for Single Fiber Model 3 S1 6 must be set to PoE ON while power supplies to PD Warning When TP Nway port is connected to TP 100FDX force mode instead of Nway partner it will result in 100HDX mode with invalid collision signal Ensure that all network nodes are configured at an identical operation mode Improper operation and flow control mode between TP and Fiber port connections will render the LAN to work poorly 9 Cable Connection Parameter 100Base X network allows 512 bit time delay between any two node stations in a collision
4. Oma Poe Power Sourcing Equipment OO On Om 802 3af Endpoint Dam La Fig 7 PoE PSE WDM Single Fiber Converter Front Panel TX 1550 RX 1310 PoE PSE TP to 100FX WDM SingleFiber Fig 8 Power from PSE to PD 6 Link Fault Pass Through This media converter supports link fault pass through LFP in TX FX converter application Link status on one port is propagated to the other port to notice the remote nodes If TP port is unplugged this converter stops transmission on fiber port This causes the remote fiber node link to fail LED shows the link failure on both TP and fiber ports If fiber link fails this converter restarts auto negotiation on TP port but always stays in the link failure state This causes the remote TP node link to fail LED also shows the link failure on both TP and fiber ports Refer to Fig 9 shown below for the normal status when the link succeeds Also refer to Fig 10 and Fig 11 for the erroneous status when TP Cable A Fiber Cable B or Fiber Cable C fails to connect Note Link fault pass through LFP function only takes effect as S1 Bit4 see Fig 12 is enabled Disabled S1 Bit4 will turn this media converter into a general one 10 100 10 100 Remote Switch Switch Station kK Fib O 1 0 O 0 e Cable Fig 9 Normal status via a pair of LFPs 10 100 10 100 Remote Switch Switch Station gt AM AT OO E 00 Cable Fig 10 The status as TP Cable A
5. domain Switch based Media Converter breaks up TP and Fiber segments collision domain to extend the cabling distance e TP Cable Limitations Cat 5 and up to 100m e Converter Fiber Cable Limitations SC ST LC Converter Models Multi mode Half duplex 412m Multi mode Full duplex 2Km Single mode Half duplex 412m Single mode Full duplex 5 20 40 60 80 100Km 10 PoE PSE TP Fiber Technical Specifications Standards IEEE802 3u 10 100Base TX 100Base FX TEEE802 3af Power over Ethernet UTP Cable Cat 5 cable and up tol00m Fiber Cable 50 125 62 5 125 or 100 1401m multi mode 8 3 125 8 7 125 9 125 or 10 125m single mode PSE Power Feeding Supports Endpoint via TP pin 1 2 3 6 LED Indicators POWER PoE TP LNK ACT 100 FX LNK ACT FDX COL 4W 7W 15 4W Data Transfer Rate Speed Forwarding Rate 100Mbps 148 800 PPS 10Mbps 14 880 PPS Flow Control IEEE802 3x compliant for full duplex Backpressure flow control for half duplex Power Requirement AC Line 100 240V 50 60Hz Power Consumption 24W Ambient Temperature 0 to 50 C Humidity 5 to 90 Dimensions 40 H x 158 W x 133 D mm Complies with FCC Part 15 Class A and CE Mark Note For connecting this device to Router Bridge or Switch please refer to the corresponding device s Technical Manual 10
6. is broken 10 100 10 100 Remote Switch Switch Station TP O QG Fiber OO O 0 Cable Fig 11 The status as Fiber Cable B or C is broken Note indicates LNK ACT LED Lit O indicates LNK ACT LED Off Warning The LFP Link Fault Pass Through function works only when both two converters own this capability in pairs Furthermore both LFP converters should be supplied only by the same manufacturer vender The connection coming from LFP converters with odd models or non LFP converters will cease the LFP function 7 LED Description LED Functi FX Green Lit when fiber connection is good LNK ACT Blinks when fiber data is present EX Lit when full duplex mode is active FDX COL Amber Off when half duplex is active Blinks when collision is present TP Green Lit when TP connection is good LNK ACT Blinks when TP data is present Lit when TP speed is 100Mbps N en Off when TP speed is 10Mbps PWR Green Lit when 5V power is coming up Green Lit when PoE feeding power is active PoE PSE TP Red Lit when PoE feeding power is disrupted In case of overtemperature overcurrent 4W Green Light when PD Class Type is Class 1 TW Green Light when PD Class Type is Class 2 15 4W Green Light when PD Class Type is Class 0 or 3 S Connecting to TP Fiber Device Converter TP Port 10 100TP AUTO FORCE selectable Bit 1 2 3 of S1 a AUTO 10 100 NWay Auto negotiation b FORCE 100 or
7. eceive 1310nm Note The 1310nm and 1550nm models must be installed in pairs i e install 1310nm model at one end and 1550nm model at the other one 3 Checklist Before you start installing the Converter verify that the package contains the following The PoE PSE TP Fiber Converter AC Power Cord This User s Manual Please notify your sales representative immediately if any of the aforementioned items is missing or damaged 4 Installing the Converter PSE TP Fiber Converter with Powered Device PD Connect the PSE media converter to an AC power source gt Install the TP media cable to the IEEE 802 3af PD converter See Fig 2 Note It can work as a pure converter that connects to the non PoE converter gt Install the media cable for network connection Warning Verify that the AC input conforms to your country AC power requirement and then insert the power plug Ensure that the power of PSE device is turned on Install the media cable for network connection Default AUTO AUTO or FORCE setting see Fig 12 SI Bit 1 TP Attach TP Cat 5 cable to TP port and the distance Port can be up to 100m Use the straight through cable to connect the switch or workstation the 10 100 TP port can support AUTO MDI X sensing Fiber Default 100FDX Port 100FDX 100HDX setting see Fig 12 SI Bit 5 Fig 1 The View of PoE PSE Media Converter