SYMS III User Manual

image

Contents

1. Groupe M V Technologies 8 Important Information 8 1 Orders To order any spare parts please see Subsection 6 2 Spare Parts and Accessories in these operating instructions 8 2 Warranty Conditions for New Units Cryo Bio System guarantees its equipment against all malfunctions caused by faulty material manufacturing defects or design errors for one year from the date specified on the warranty certificate Parts and services are free of charge during this period Any malfunction must occur within twelve months of the effective warranty date and while using the equipment in strict accordance with these operating instructions Warranty exclusions include the following e If the malfunction is caused by an unauthorized procedure on the unit e If the malfunction is caused by a failure to comply with the technical specifications and these operating instructions e If the malfunction is caused by a situation of force majeure Based on the above warranty Cryo Bio System shall repair or replace the parts that become unusable during the warranty period for reasons outlined above The implementation of this warranty i e the repair and replacement of all or part of the delivered equipment is not liable to extend the warranty period Any dispute arising from the interpretation and or execution of these warranty conditions shall be subject exclusively to French law The Courts of Alencon shall be the only courts of competent jurisdicti
2. Place the product up against the sensor The product is sealed automatically Repeat the sealing process for the other end of the straw Steps 6 to 8 AUTOMATIC SONA RWN gt START START MLSTRAV PRECHAUFFAGE EN COURS a sania x ene f a SOUDURE EN COURS READY N YOU CAN SEAL ss Version 03 2015 15 Copyright Cryo Bio System 2014 Pictures and specifications are non binding This document cannot be disclosed to third parties without written authorization by Cryo Bio System SYMS III Cryo Bio System Operating instructions Groupe I M V Technologies CBS High Security Tube Proceed as with the CBS High Security Straw but select CBS High Security Tube in Step 3 and use the support designed for the CBS High Security Tube in Step 6 HSV High Security Vitrification Straw Automatic Mode will not operate for this product Version 03 2015 16 Copyright Cryo Bio System 2014 Pictures and specifications are non binding This document cannot be disclosed to third parties without written authorization by Cryo Bio System Groupe M V Technologies SYMS III Cryo Bio System Operating instructions 5 3 Run up time and changeover time between modes The following data are provided for information purposes only and were measured while using the SYMS III unit in an environment with an ambient temperature of 25 C Data Time Run up time for HSV Straw 45 seconds Run up ti
3. on the rating plate Make sure the sealer is mounted on a flat stable support 2 4 Transport and Storage Unplug the unit from the power source Store and transport the unit and its accessories in the original packaging to prevent any damage Store the unit in a dry place Avoid any shock or jolts while transporting the SYMS III Version 03 2015 4 Copyright Cryo Bio System 2014 Pictures and specifications are non binding This document cannot be disclosed to third parties without written authorization by Cryo Bio System SYMS III Cryo Bio System Operating instructions Groupe M V Technologies 3 SYMS III 3 1 Overview The SYMS III unit consists of the following e the sealer Touch Protective screen cover ON OFF switch Side view USB port Product support Side view right Presence sensor Side view left Use only for a software update Any use without Cryo Bio System s specific information instructions is forbidden Version 03 2015 5 Copyright Cryo Bio System 2014 Pictures and specifications are non binding This document cannot be disclosed to third parties without written authorization by Cryo Bio System SYMS III Cryo Bio System Operating instructions Groupe M V Technologies e the external power supply and cord 3 2 Welding unit Front view Top view Version 03 2015 6 Copyright Cryo Bio System 2014 Pictures and specifications are n
4. 8 Copyright Cryo Bio System 2014 Pictures and specifications are non binding This document cannot be disclosed to third parties without written authorization by Cryo Bio System SYMS III Cryo Bio system Operating instructions Groupe M V Technologies 4 Initial Startup Reminder The SYMS III sealer is configured solely for sealing CBS High Security sterile and non sterile products specified on page 3 4 1 Sealer Setup Electrical Connection Connect to power supply as follows e Connect the plug to the power source e Connect the 4 pin connecter to the back of the sealer Positioning the Support Install either the CBS straw and HSV straw support or the CBS tube support depending on the type of product to be sealed Version 03 2015 9 Copyright Cryo Bio System 2014 Pictures and specifications are non binding This document cannot be disclosed to third parties without written authorization by Cryo Bio System SYMS III Cryo Bio System Operating instructions Groupe M V Technologies Turning on the Sealer Switch the ON OFF button to the l position The following screen will display for about 3 seconds Cryo Bio System IWY Groupe I M V Technologies SYSTEM START UP eee The following screen offers the option of cleaning the jaws i YOU HAVE TO CHANGE THE JAWS IN Q SEALING DO YOU WANT TO PERFORM THIS OPERATION NOW ES If YES is selected the following screen
5. Cryo Bio System Groupe I M V Technologies SYMS III MANUAL SEALER For CBS High Security straws CBS High Security tubes and HSV High Security Vitrification Straw Copyright Cryo Bio System 2015 This document cannot be disclosed to third parties without written authorization by Cryo Bio System Cryo Bio System ZI n 1 Est 61300 L Aigle contact cryobiosystem imv com Tel 33 0 233 346 464 Fax 33 0 233 341 198 1 2 3 4 SYMS III Cryo Bio System Operating instructions Groupe M V Technologies Table of Contents FOON O aore E E E E E E E E E E A E A E 3 MAUGO err E E E E A E E E E E E A EE 3 2 1 ADPU AOD eaire EEE EEA E EEE EE 3 2 2 Protection and Safety sssesseseseecesescesesescesesceecescsceeesescesesceeeseecesesceeesesceseeee 4 Electrical Safety Standards sssesessecesescecessecesesceceseeceoesceoeseeosoeeceeoeoesoroseeeceseeeeoeo 4 2 3 Setup Safety Requirements esriscrivirrsisiserreis eearecesevaveds tevuvedeseirncedsseeevessseeesedesslees 4 DO CUD A E PE T PR PE E E A E A A ale eos Sele oeaoealees 4 AU ON AY DOTE eer Eran ER EE AREER EER 4 PC OMS ING IONS Ea AEE EE EEA EE EAEE EOT ae emeaewerereamacnes 4 2 4 transport and Storag sssrini snien rire R 4 AM a E EE 5 3 1 WVEIVIEW oier EE EEA AA A AAA A IE AE 5 3 2 W N erea E E EE E EEEE 6 3 3 POLCE UVE COVED pacaensuien evenceepisenones AEE E E AEE E T EEEE 7 3 4 Controller Touch SCrEEN serrrrirrrreitriri ntir Porre Er p RE
6. NTE PPEKT TEEPU RIER EREKE ENEE 7 3 5 PO a E E E cts eect ocdeusecueeees 8 CBS Straw and HSV Straw support removable ssssssssesessesesescssscscoecesescsescscecsesesseeesees 8 CBS TUDE SUPO o rA a ER eee nto es serene ne een cases 8 a U ea a ce one cco nea E A oe nee A RAN 9 4 1 CO SCID er a E E E 9 Electrical CONNECTION teccatencedustantewnstoceedes EEEE EERE EETA 9 POSITIONING ENG SUDDON ereer rer n E S A 9 CADO Oly WG Seale een err A 9 4 2 EA Die S PA E E A E pase E E dees E E I O E E E O E E I OE D A T T 11 AUdIO SOECINOS seciiesirserssipreri nitisi eitn nint rS EEREN rE NERE RETEN TETE NEEESE TEER E 12 Eee ta a A e E TE E EE EEEE EE T EE EE ET EEEE EE 12 Operatie MOTO s srcriserisis tsitis irer EREE ERUEN EEEREN EE EEEE CE EERENS NEE CENETA seaweeds savesaieseawcede sex 13 5 1 NAIA e e c P E A E A AA E E A gece ses 13 CB Mion Security SUTAWS 4 n c cccsesescacecucadacsasoscanasacsdacsaveseocasuasdessesehendesnendecsasaueneas 13 CBO TST DOCU TUDO sige cos es oceeaecnecncoacacenuectaoncceacaseneaatseaoceasaseaeneia en ocenseeacesetaanecs 14 HSV High Security Vitrification Straw ccecccccncccccecccecccceesscesecceeescceesccesescesescceees 14 5 2 AUCO ALIS OCS x ashes essen cet eu ern oe EEEE E oot rae on owe nem ENE E EEEE ANR 15 OB FS SOCUNILY SU AWS E E E E A E A E E E A cnet ee ucurseses 15 CBS MION secur TUDO sins oetaccessatscenemetaseensscseceuececennescsces sp ENEAN 16 HSV High Security Vitrification Straw
7. and Chinese One extra language option from the following list can be added at the factory Italian German Portuguese and Russian LANGUAGE SETTINGS Sm il iJ Version 03 2015 12 Copyright Cryo Bio System 2014 Pictures and specifications are non binding This document cannot be disclosed to third parties without written authorization by Cryo Bio System SYMS III Cryo Bio System Operating instructions Groupe I M V Technologies 5 Operating Mode Preamble After each sealing operation the sealing jaws are automatically recentered recoil and back into position 5 1 Manual Mode Manual sealing can begin once two conditions are met e The presence sensor must detect a container the CBS High Security products specified on page 4 e The operator must press the SEAL button CBS High Security Straws Select MANUAL in the Main Menu Select STERILE or NON STERILE Select the type of CBS High Security Straw to be sealed Wait until the preheating is completed Sealing can begin when READY appears on the screen Place the product onto the proper support Slide the product forward until it touches the detector Push SEAL Repeat the sealing process for the other end of the straw Steps 6 to 8 AUTOMATIC eS ee ee a START START PRECHAUFFAGE EN COURS eos SOUDURE EN COURS READY nee YOU CAN SEAL aT oa BACK Version 03 2015 13 Copy
8. ecifically designed for use with CBS High Security 0 3 and 0 5 ml straws and follow Cryo Bio System s recommendations for using the CBS High Security tube HSV High Security Vitrification Kit and CBS High Security 2 ml tissue straw Caution Only products at room temperature can be sealed with the SYMS III sealer 2 Introduction 2 1 Applications The SYMS III sealer is a benchtop unit that can be used under a laminar flow cabinet It uses a thermal process to seal CBS High Security 0 3 ml 0 5 ml and 2 ml straws CBS High Security tubes as well as HSV High Security Vitrification straws in applications related to Epidemiological research departments Biobanks Serum banks Cellular and gene therapy units Vaccine manufacturing pharmaceutical companies living cells Gene banks animal vegetal microbiological Reproductive biology laboratories Gamete and gonadal tissue banks Version 03 2015 3 Copyright Cryo Bio System 2014 Pictures and specifications are non binding This document cannot be disclosed to third parties without written authorization by Cryo Bio System SYMS III Cryo Bio System Operating instructions Groupe M V Technologies 2 2 Protection and Safety Electrical Safety Standards e Class product requiring installation with properly protected earth connection e Pollution degree 2 2 3 Setup Safety Requirements Setup Safe use of this unit requires its connection to a grounded complian
9. ed Restart the sealer If the alert continues to sound please contact a Cryo Bio System customer service technician 33 2 33 346 444 6 5 Centring Jaws Press the Main Menu button at the bottom left of the screen to check that the sealing jaws are correctly centered with the straw tube support and the presence sensor Version 03 2015 21 Copyright Cryo Bio System 2014 Pictures and specifications are non binding This document cannot be disclosed to third parties without written authorization by Cryo Bio System SYMS III Cryo Bio System Operating instructions Groupe M V Technologies 7 Technical Specifications 7 1 General Specifications e Dimensions Length 335 mm Width 250 mm Height 105 mm e Weight 3 3 kg 7 2 Operating Conditions e For indoor use only e Operating temperature 5 at 30 C e Maximum relative ambient humidity 80 e Operating environment The unit cannot be used at an altitude higher than 2 000 m or in an explosive or corrosive environment 7 3 Power Supply e External power supply Supply voltage 100 240 V Supply frequency 50 60 Hz Power consumed 120 W max Output 12V with a 4 pin DIN miniconnector e Sealer Unit Voltage 12 15 V Version 03 2015 22 Copyright Cryo Bio System 2014 Pictures and specifications are non binding This document cannot be disclosed to third parties without written authorization by Cryo Bio System SYMS III Cryo Bio System Operating instructions
10. me for CBS Straws 49 seconds Run up time for CBS Tube 1 minute HSV Straw CBS Straws changeover time 18 seconds HSV Straw CBS Tube changeover time 10 seconds CBS Straws HSV Straw changeover time 4 seconds CBS Tube HSV Straw changeover time 4 seconds CBS Tube CBS Straws changeover time 4 seconds CBS Straws Tube changeover time 4 seconds Hold time at temperature before standby 30 minutes and 17 seconds Tube or straw cooling time to 39 C 24 minutes and 36 seconds 5 4 Sealing time The following data are provided for information purposes only and were measured while using the SYMS III unit in an environment with an ambient temperature of 25 C Container Sealing time For 1 prefilled CBS straw 15 seconds For 1 prefilled CBS tube 15 seconds For 1 prefilled HSV straw 5 seconds Sealing time with laboratory technician handling time For 10 prefilled CBS straws 3 minutes and 20 seconds Container For 10 prefilled CBS tubes 2 minutes and 30 seconds For 10 prefilled HSV straws 1 minutes and 20 seconds Version 03 2015 17 Copyright Cryo Bio System 2014 Pictures and specifications are non binding This document cannot be disclosed to third parties without written authorization by Cryo Bio System SYMS III Cryo Bio System Operating instructions Groupe M V Technologies 6 Maintenance 6 1 Servicing There is no specific maintenance required for the main mechanical and elec
11. on this also applies to the introduction of third parties and multiple defendants 8 3 Exclusion of Liability Cryo Bio System is not liable for damages caused by outside influences or any inappropriate handling and use that does not comply with the recommendations stipulated in these operating instructions Please refer to the fields of application see 2 1 Applications Applications and electrical specifications see 7 3 Power Supply Power Supply in these instructions 8 4 Contact Cryo Bio System ZI n 1 Est 61300 L Aigle Tel 33 0 233 346 464 Fax 33 0 233 341 198 Tel Customer Service 33 0 233 346 444 D cret n 2012 617 du 2 mai 2012 relatif a la Fax Customer service 33 0 233 849 504 gestion des d chets de piles et accumulateurs contact c yobiosystem imv com et d quipements lectriques et lectroniques Version 03 2015 23 Copyright Cryo Bio System 2014 Pictures and specifications are non binding This document cannot be disclosed to third parties without written authorization by Cryo Bio System SYMS III Cryo Bio System Operating instructions Groupe M V Technologies Notes Version 03 2015 24 Copyright Cryo Bio System 2014 Pictures and specifications are non binding This document cannot be disclosed to third parties without written authorization by Cryo Bio System
12. on binding This document cannot be disclosed to third parties without written authorization by Cryo Bio System SYMS III Cryo Bio System Operating instructions Groupe I M V Technologies 3 3 Protective cover When the SYMS IlI sealer is operating removing the protective cover will immediately trigger an audible warning signal An alert message will be displayed on the screen and the unit will shut down 3 4 Controller Touch Screen The MAIN MENU consists of three areas 1 Sealing Modes o Automatic o Manual The selected mode remains highlighted START START STERILE NON STERILE 2 Soldering containers status o Sterile products o Non sterile products 3 Handling and parameters o Jaws centring o Cleaning o Settings Version 03 2015 7 Copyright Cryo Bio System 2014 Pictures and specifications are non binding This document cannot be disclosed to third parties without written authorization by Cryo Bio System SYMS III Cryo Bio System Operating instructions Groupe M V Technologies 3 5 Supports Two types of supports are delivered with the SYMS III sealer to provide optimal sealing of all products offered by Cryo Bio System e CBS straw support for CBS High Security 0 3 0 5 and 2 ml straws and the HSV High Security Vitrification straw e CBS Tube Support for CBS High Security tube CBS Straw and HSV Straw support removable CBS tube support Version 03 2015
13. right Cryo Bio System 2014 Pictures and specifications are non binding This document cannot be disclosed to third parties without written authorization by Cryo Bio System SYMS III Cryo Bio System Operating instructions Groupe I M V Technologies CBS High Security Tube Proceed as with the CBS High Security Straw but select CBS High Security Tube in Step 3 and use the support designed for the CBS High Security Tube in Step 6 HSV High Security Vitrification Straw Proceed as with the CBS High Security Straw but select HSV Straw in Step 3 gt Caution the HSV High Security Vitrification Straw can only be sealed in MANUAL mode with the STERILE option selected Version 03 2015 14 Copyright Cryo Bio System 2014 Pictures and specifications are non binding This document cannot be disclosed to third parties without written authorization by Cryo Bio System SYMS III Cryo Bio System Operating instructions Groupe I M V Technologies 5 2 Automatic Mode Automatic sealing will begin as soon as the presence detector detects one of the containers supported by the SYMS III sealer CBS High Security Straws Select AUTOMATIC in the Main Menu Select STERILE or NON STERILE Select the type of CBS High Security Straw to be sealed Wait until the preheating is completed You can begin sealing when READY appears on the screen Place the product onto the proper support
14. s will appear in successive order e CLEANING e MAIN MENU Version 03 2015 10 Copyright Cryo Bio System 2014 Pictures and specifications are non binding This document cannot be disclosed to third parties without written authorization by Cryo Bio System SYMS III Cryo Bio System Operating instructions Groupe I M V Technologies CLEANING N GY YOU CAN OPEN THE PROTECTIVE HOOD TO CLEAN THE SEALLING AREA Cf Subsection 6 3 Cleaning the jaws If NO is selected the MAIN MENU will appear START START STERILE NON STERILE 4 2 Settings SETTINGS The SETTINGS menu groups the standard settings e Audio e Language e Back A AUDIO LANGUAGES Version 03 2015 11 Copyright Cryo Bio System 2014 Pictures and specifications are non binding This document cannot be disclosed to third parties without written authorization by Cryo Bio System SYMS III Cryo Bio System Operating instructions Groupe I M V Technologies Audio Settings By default audible warning signals are turned on These alerts can be turned off by selecting the SETTINGS menu in the MAIN MENU then AUDIO A ACTIVATE AUDIO ALERTS i Language Settings By default the menus on the touch screen are displayed in French The language can be changed by selecting the SETTINGS submenu in the main menu then LANGUAGE Four languages are now available English French Spanish
15. sssseseseesesesceseseecesescecesesceeeseesesesoeeeseeceeeee 16 5 3 Run up time and changeover time between modes ssesesessesescseccscescsescesceseseeceeee 17 5 4 C E ea a E E REET 17 MaN ENC arrar ge eae a A A E E E A NE 18 6 1 ERE o eee eee ee een E EE T 18 6 2 Spare Parts and Accessories sssseceseeseceseeceseececeseececeeceeceorececeeeeceoeeeeceeeeesoeo 18 6 3 Ceann St IWS aee E pate alas cit nenanawie seaeee 18 6 4 Manaoino AlGIES Sucdencitwcucns hoe tecsastwessns eoeteceastncacas sontecwanacdenstontacecesnceeneaentadecess 20 creana UNG JAWS 22 5i viarcteestassteeuienciesssaretessiescteseseendess isacierwseeetess ioacieenserecese aac 20 DBC MING THe OV Cl 322i acta staecescieseiar etal ciekedeseserstats ies cieseseseteaviessieseseweeewiasa 20 DS COV ENO eraser eE EEEE seetoueeecetdcavescetenstecersecssectausaes 21 6 5 Centring JOWS ssesessescesoesoesossesoesoesoesoesossesoesossoesoscesoesoesoesoesoecesoesoesoesoeee 21 Techical Specificatll ONS escsssenccvqscecescatecwesecesqceucatecwassasseeesuatecwassasseeusuatecweoeassesenuase 22 7 1 Genelia SWPCCINCAUONS cccacuvesstetacslesaccvanstesseslosasevassueesustesasevasseouseetecstecasaeeeuuese 22 7 2 Deane Cona ONS o txccesserecede ve varecuseinusede EEES E EEEE T EE EE E EEEE T ENEE EOTS 22 7 3 POW Ol UY ceee adnan een oe ees fs crete See fa nae ho nee nce ioe E 22 HMO PUA MAT OPN AE OW ere E E ceaeecn ewer ee nece a cuno wan caeeeces 23 8 1 OPOS a E E uae ees cusss cas c
16. t electrical source The SYMS III sealer is powered by a low voltage external power supply The voltage and frequency must comply with the instructions in the rating plate The power cable must be in perfect condition If the cable looks damaged in any way turn off the power supply to the sealer immediately Call a specialist to replace the cable or contact the Cryo Bio System Technical Service Department Cautionary note Sealing and press time specifications must never be modified by the user under any circumstances Failure to obey the recommendations of these operating instructions may compromise the protection provided by the equipment The device must not be opened Any change and or electrical repairs may only be carried out by a qualified individual under the supervision of a Cryo Bio System technician Recommendations The seal integrity of all CBS High Security Products listed on page 3 is guaranteed thanks to three key sealing settings specifically adapted to the products constituent materials the temperature force and pressure time between the two SYMS III jaws Caution The area in and around the CBS High Security product sealing area must be kept clean and dry The sealing support must be adapted to the product to be sealed see 3 5 Supports Do not operate the sealer when empty without a CBS High Security Straw CBS High Security Tube or HSV High Security Vitrification Straw present Follow the safety instructions
17. ton Finish Close the protective cover O J KR W Version 03 2015 19 Copyright Cryo Bio System 2014 Pictures and specifications are non binding This document cannot be disclosed to third parties without written authorization by Cryo Bio System SYMS III Cryo Bio System Operating instructions Groupe I M V Technologies 6 4 Managing Alerts Cleaning the Jaws The jaws can be cleaned only if their temperature is below 40 C CLEANING ALARM A YOU ARE GOING TO PERFORM A A MAINTENANCE OPERATION SEALING AREA IS COOLING DOWN PLEASE WAIT C DON T OPEN THE PROTECTIVE HOOD Opening the Cover ALARM YOU HAVE OPENED THE PROTECTIVE HOOD PLEASE CLOSE THE PROTECTIVE HOOD While the protective cover is open an ALERT screen is displayed and an audible warning signal is generated As soon as the cover is closed the MAIN MENU appears Version 03 2015 20 Copyright Cryo Bio System 2014 Pictures and specifications are non binding This document cannot be disclosed to third parties without written authorization by Cryo Bio System SYMS III Cryo Bio System Operating instructions Groupe I M V Technologies System Error ALARM A A SYSTEM ERROR DETECTED PLEASE CONTACT CUSTOMER SERVICES TEL SAV 33 233 346 444 ERROR CODE ERPEL When a system error occurs an ALERT screen is displayed and 3 audible warning signals are generated every 2 minutes The sealer is automatically lock
18. trical parts of the SYMS III sealer However it is strongly recommended that you clean the sealing jaws regularly especially if they become accidentally fouled while sealing the CBS High Security straws HSV High Security Vitrification straw and CBS High Security tube The jaws can perform 3 000 seals Please contact the Technical Service Department in the event of any damage or wear 6 2 Spare Parts and Accessories Product Number CBS straw and HSV Straw Support 025590 CBS Tube Support 025591 Protective cover 025592 Reminder Only a certified Cryo Bio System Specialist or Cryo Bio System Technician is authorized to perform repair work on the SYMS III sealer 6 3 Cleaning the Jaws The CLEANING function keeps the jaws apart in order clean them 1 Select CLEANING on the Main Menu The following screen will appear MAIN MENU CLEANING AUTOMATIC SS 7 START START YOU CAN OPEN THE PROTECTIVE HOOD TO CLEAN THE SEALLING AREA STERILE NON STERILE 2 Open the protective cover Version 03 2015 18 Copyright Cryo Bio System 2014 Pictures and specifications are non binding This document cannot be disclosed to third parties without written authorization by Cryo Bio System SYMS III Cryo Bio System Operating instructions Groupe I M V Technologies Clean the jaws with a cotton swab moistened with distilled water or alcohol Dry with a dry cotton swab or cloth Press the but
19. uuaeconeneyo eee ceesnseseaeeye ue oee ee syaoeee eens 23 8 2 Warranty Conditions Tor New UNIS ccccsissccstetaedesewiasccctuteedeavetencdagetesdasesteeceesetetes 23 Oo JIEXEWISION OF LG DIME ncccecceccceccone cones cease TE TENTEN EEEE 23 oc ae OO Oe ee E ee ene ee ere ee ree 23 Version 03 2015 2 Copyright Cryo Bio System 2014 Pictures and specifications are non binding This document cannot be disclosed to third parties without written authorization by Cryo Bio System SYMS III Cryo Bio System Operating instructions Groupe M V Technologies 1 Foreword Before using we recommend that you read these operating instructions carefully in order to familiarize yourself with the SYMS III sealer and obtain total satisfaction These operating instructions present the sealer s various components as well as their item numbers essential for ordering spare parts see 6 2 Spare Parts and Accessories The SYMS IlI sealer cannot be used to seal any products other than those specified on the list below e Sterile products o CBS High Security 0 3 ml and 0 5 ml straws o CBS High Security 2 ml straws o CBS High Security tubes o HSV High Security vitrification straws e Non sterile products o CBS High Security 0 3 ml and 0 5 ml straws o Co X High Security 0 3 ml and 0 5 ml straws o CBS High Security tubes To guarantee the seal integrity of products sealed with the SYMS III only use filling nozzles and tips sp

Download Pdf Manuals

image

Related Search

Related Contents

QCSPCChart SPC Control Chart Tools for .Net CF - Quinn  Pen DVR User`s Manual (v2.1)  Descarga de manual de instalación  Y-cam HomeMonitor  ISA / PC-104 High Speed Interface User`s Manual  DXT 5000 Active Matrix  Sea Gull Lighting 77180-965 Installation Guide  If you have any questions or concerns, Please call our toll  