FX3U-4AD-ADP USER`S MANUAL

image

Contents

1. 3 4 Grounding Grounding should be performed as stated below e The grounding resistance should be 100 Q or less e Independent grounding should be performed for best results When independent grounding is not performed perform shared grounding of the following figure For details refer to the respective PLC User s manual Hardware Edition Other Other Other PLC equipment PLC equipment PLC equipment Independent grounding Shared grounding Common grounding Best condition Good condition Not allowed e The grounding wire size should be AWG 22 20 0 3 0 5 mm e The grounding point should be close to the PLC and all grounding wire should be as short as possible 4 Specifications STARTUP AND MAINTENANCE PRECAUTIONS Z CAUTION e Do not disassemble or modify the PLC Doing so may cause fire equipment failures or malfunctions For repair contact your local Mitsubishi Electric representative Do not drop the product or exert strong impact to it Doing so may cause damage DISPOSAL PRECAUTIONS Z CAUTION e Please contact a certified electronic waste disposal environmentally safe recycling and disposal of your device company for the TRANSPORTATION AND STORAGE PRECAUTIONS ACAUTION e The product is a precision instrument During transportation avoid any impacts Failure to do so may cause failures in the product After transportation verify the op
2. Product FX3U 4AD ADP analog input special adapter Accessories User s manual This manual A 1 2 External Dimensions Part Names and Terminal Layout 5 10 ja 6 fFrasan aoe 7 K 8 ay 8 2 5 oel E 2o age 5 co E EO Special adapter p 0 7 connector cover is removed Weight Approx 0 1 kg 0 22 Ibs DIN rail mounting groove DIN rail DIN46277 2 Name plate 3 Special adapter slide lock Used to connect additional special adapters onto the left side of this special adapter 4 Special adapter connector cover Remove this cover to connect additional special adapters to the left side 5 Direct mounting hole 2 holes of 4 5 0 18 mounting screw M4 screw Not used when connecting to FX3GC FX3UC Series PLC 6 POWER LED green Lit while 24 V DC power is supplied properly to terminals 24 and 24 7 Terminal block European type Connect the analog voltage current signal and 24 V DC power supply 8 Special adapter connector Used to connect this special adapter to PLC main unit or special adapter 9 DIN rail mounting hook 10 Special adapter fixing hook 11 Special adapter connector Used to connect communication or analog special adapters to the left side of the 4AD ADP 2 Installation For installation uninstallation details refer to the respective PLC User s manual Hardware Edition INSTALLATION PRECAUTIONS 7 WARN IN
3. ELECTRIC PROGRAMMABLE CONTROLLERS MELSEG F FX3uU 4AD ADP USER S MANUAL F X3u JY997D13901 This manual describes the part names dimensions mounting and specifications of the product Before use read this manual and the manuals of all relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions Store this manual in a safe place so that it can be taken out and read whenever necessary Always forward it to the end user Registration The company and product names described in this manual are registered trademarks or the trademarks of their respective companies Effective April 2013 Specifications are subject to change without notice 2005 Mitsubishi Electric Corporation Manual Number Revision K Date April 2013 Safety Precaution Read these precautions before use This manual classifies the safety precautions into two categories WARNING and CAUTION Indicates that incorrect handling may cause hazardous Z WARNING conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous Z CAUTION conditions resulting in medium or slight personal injury or physical damage Depending on the circumstances procedures indicated by A CAUTION may also cause severe injury It is important to follow
4. all precautions for personal safety Associated Manuals Manual name Manual No FX3S FX3G FX3GC FX3U Describes specifications for FX3UC Series JY997D16701 analog control and User s M l MODEL CODE programming method for Po RAE n 09R619 FX3S FX3G FX3GC FX3U Analog Control Edition FX3UC Series PLC FX3S FX3G FX3GC FX3U FX3UC Series JY997D16601 Describes PLC programming Programming Manual MODEL CODE for basic applied instructions Basic amp Applied 09R517 and devices Instruction Edition FX3S Series JY997D48601 Explains FX3S Series PLC User s Manual MODEL CODE specifications for I O wiring Hardware Edition 09R535 installation and maintenance FX3G Series JY997D31301 Explains FX3G Series PLC User s Manual MODEL CODE specifications for I O wiring Hardware Edition 09R521 installation and maintenance FX3GC Series JY997D45401 Explains FX3GC Series PLC User s Manual MODEL CODE specifications for I O wiring Hardware Edition 09R533 installation and maintenance FX3U Series JY997D16501 Explains FX3U Series PLC User s Manual MODEL CODE specifications for I O wiring Hardware Edition 09R516 installation and maintenance FX3UC Series JY997D28701 Explains FX3UC Series PLC User s Manual MODEL CODE specifications for I O wiring Hardware Edition 09R519 installation and maintenance How to obtain manuals For product manuals or documents consult with the Mitsub
5. wire single wire aa Stick terminal with insulating sleeve Insulation sleeve Contact area Crimp area Z 8mm 0 31 2 6mm 0 1 14mm 0 55 9mm 0 35 E When using a stick terminal with insulating sleeve choose a wire with proper cable sheath referring to the above outside dimensions or otherwise the wire cannot be inserted easily The tightening torque must be 0 22 to 0 25 Nem Do not tighten terminal screws exceeding the specified torque Failure to do so may cause equipment failures or malfunctions 3 2 Power Supply Wiring For the power supply wiring refer to the following manual FX3S FX3G FX3GC FX3U FX3UC Series User s Manual Analog Control Edition 3 3 Wiring of Analog Input For the terminal configuration refer to Section 1 2 Daina current Terminal 4AD ADP brocki TO choo oad a 2500 gt r 47kQ ICOMC TEE 147k cho ums a 47k COMO Mel 15V aa 24 e Sore 24 F 7 a rh Groundin g Ground resistance 100 Q or less VO O ch O Orepresents the channel number 1 Use 2 core shielded twisted pair cable for the analog input lines and separate the analog input lines from other power lines or inductive lines 2 Make sure to short circuit the VD1 and IO terminals when current is input O input channel number 3 24 V DC service powe
6. 0 mA DC range Input resistance 194 kQ Input resistance 250 Q Maximum 0 5 V 15 V 2 mA 30 mA absolute input Digital output 12 bits binary 11 bits binary Resolution 2 5 mV 10 V 4000 10 pA 16 mA 1600 e 40 5 50 mV for full scale e 0 5 80 pA for full scale of 10 V when ambient of 16 mA when ambient temperature is 25 C 5 C temperature is 25 C 5 C e 1 0 100 mV for full e 1 0 160 A for full scale scale of 10 V when ambient of 16 mA when ambient temperature is 0 C to 55 C temperature is 0 C to 55 C Total accuracy FX3U FX3UC Series PLC 200 us A D conversion The data will be updated at every scan time of the PLC time e FX3S FX3G FX3GC Series PLC 250 us The data will be updated at every scan time of the PLC 4080 nL EF 4000 E EIEE Input characteristics yndjno jey6ig yndjno eysa i I l i l 0 4mA gt 20mA 20 4 m o gt 10V 10 2V 7 Analog input A Analog input e The photocoupler is adopted to insulate the analog input area from the PLC Insulation e The DC DC converter is adopted to insulate the power supply method i A line from the analog input area e Channels are not insulated from each other Occupied 0 point This number is not related to the maximum number of points input output points of the PLC This manual confers no industrial property rights or any rights of any other kind nor d
7. G e Make sure to cut off all phases of the power supply externally before attempting installation or wiring work Failure to do so may cause electric shock or damage to the product INSTALLATION PRECAUTIONS Z CAUTION e Use the product within the generic environment specifications described in PLC main unit manual Hardware Edition Never use the product in areas with excessive dust oily smoke conductive dusts corrosive gas salt air Cl2 H2S SOz or NO2 flammable gas vibration or impacts or expose it to high temperature condensation or rain and wind If the product is used in such conditions electric shock fire malfunctions deterioration or damage may occur When drilling screw holes or wiring make sure cutting or wire debris does not enter the ventilation slits Failure to do so may cause fire equipment failures or malfunctions Do not touch the conductive parts of the product directly Doing so may cause device failures or malfunctions Connect special adapter securely to their designated connectors Loose connections may cause malfunctions 2 1 Connection to the PLC This section describes the connection method to the PLC FX3U Series PLC is used for the following example For installation method to other PLCs refer to the respective PLC User s manual Hardware Edition Procedure 1 Turn off the power Disconnect all the cables connected to the PLC main unit and special adapter and demount the main un
8. Input resistance 194 kQ Input resistance 250 Q Maximum absolute input 0 5 V 15 V 2 mA 30 mA Digital output 12 bits binary 11 bits binary Resolution 2 5 mV 10 V 4000 10 pA 16 mA 1600 Total accuracy e 0 5 50 mV for full scale e e 1 0 100 mV for full of 10 V when ambient temperature is 25 C 5 C scale of 10 V when ambient temperature is 0 C to 55 C 0 5 80 pA for full scale of 16 mA when ambient temperature is 25 C 5 C 1 0 160 pA for full scale of 16 mA when ambient temperature is 0 C to 55 C A D conversion time FX3U FX3UC Series PLC 200 us The data will be updated at ever The data will be updated at ever y scan time of the PLC FX3S FX3G FX3GC Series PLC 250 us y scan time of the PLC Input characteristics as So i O yndjno jey o gt 10v 10 2V Analog input R a e yndjno jeysiq 0 4mA gt 20mA l i l 1 l iF l 1 1 20 4 Analog input m from the PLC e The photocoupler is adopted to insulate the analog input area Insulation e The DC DC converter is adopted to insulate the power supply method i n line from the analog input area e Channels are not insulated from each other Occupied 0 point This number is not related to the maximum number of points input output points of the PLC This manual confers no industrial property rights or an
9. JY997D13901K JAPANESE J Side B ENGLISH MITSUBISHI ELECTRIC PROGRAMMABLE CONTROLLERS MELSEG F FX3uU 4AD ADP USER S MANUAL F X3u JY997D13901 This manual describes the part names dimensions mounting and specifications of the product Before use read this manual and the manuals of all relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions Store this manual in a safe place so that it can be taken out and read whenever necessary Always forward it to the end user Registration The company and product names described in this manual are registered trademarks or the trademarks of their respective companies Effective April 2013 Specifications are subject to change without notice 2005 Mitsubishi Electric Corporation Manual Number Revision K Date April 2013 Safety Precaution Read these precautions before use This manual classifies the safety precautions into two categories WARNING and CAUTION Indicates that incorrect handling may cause hazardous Z WARNING conditions resulting in death or severe injury g jury Indicates that incorrect handling may cause hazardous NCAUTION conditions resulting in medium or slight personal injury or physical damage Depending on the circumstance
10. erations of the product 4 1 Applicable PLC Model name Applicability FX3S Series PLC Ver 1 00 or later from first production FX3G Series PLC Ver 1 00 or later from first production FX3GC Series PLC Ver 1 40 or later from first production FX3U Series PLC Ver 2 20 or later from first production FX3UC Series PLC Ver 1 20 or later from the production manufactured in May 2004 with SER No 45 The version number can be checked by monitoring D8001 D8101 as the last three digits indicate it 4 2 General Specifications Items other than the following are equivalent to the those of the PLC main unit For general specifications refer to the respective PLC User s manual Hardware Edition Item Specification Dielectric withstand voltage 500 V AC for one minute Between all terminals and ground terminal of PLC Insulation resistance 5 MQ or more by 500 V megger DC main unit 4 3 Power Supply Specifications Item Specification AID conversion circuit driving power 24 V DC 20 15 40 mA for 24 V DC Connect a 24 V DC power supply to the terminal block Interface driving power 5V DC 15 mA main unit 5 V DC power is supplied from the internal power supply of 4 4 Performan ce Specifications Description Item Voltage input Current input Analog input 0 to 10 V DC 4 to 20 mA DC range
11. g installation or wiring work Failure to do so may cause electric shock or damage to the product WIRING PRECAUTIONS Z CAUTION e When drilling screw holes or wiring make sure cutting or wire debris does not enter the ventilation slits Failure to do so may cause fire equipment failures or malfunctions Make sure to observe the following precautions in order to prevent any damage to the machinery or accidents due to abnormal data written to the PLC under the influence of noise 1 Do not bundle the power line or shield of the analog input output cable together with or lay it close to the main circuit high voltage line or load line Otherwise noise disturbance and or surge induction are likely to take place As a guideline lay the control line at least 100mm 3 94 or more away from the main circuit high voltage line or load line 2 Ground the shield of the analog input output cable at one point on the signal receiving side However do not use common grounding with heavy electrical systems Make sure to properly wire to the terminal block European type in accordance with the following precautions Failure to do so may cause electric shock equipment failures a short circuit wire breakage malfunctions or damage to the product The disposal size of the cable end should follow the dimensions described in the manual Tightening torque should follow the specifications in the manual Twist the end of strand wire and
12. he product WIRING PRECAUTIONS Z CAUTION e When drilling screw holes or wiring make sure cutting or wire debris does not enter the ventilation slits Failure to do so may cause fire equipment failures or malfunctions Make sure to observe the following precautions in order to prevent any damage to the machinery or accidents due to abnormal data written to the PLC under the influence of noise 1 Do not bundle the power line or shield of the analog input output cable together with or lay it close to the main circuit high voltage line or load line Otherwise noise disturbance and or surge induction are likely to take place As a guideline lay the control line at least 100mm 3 94 or more away from the main circuit high voltage line or load line 2 Ground the shield of the analog input output cable at one point on the signal receiving side However do not use common grounding with heavy electrical systems Make sure to properly wire to the terminal block European type in accordance with the following precautions Failure to do so may cause electric shock equipment failures a short circuit wire breakage malfunctions or damage to the product The disposal size of the cable end should follow the dimensions described in the manual Tightening torque should follow the specifications in the manual Twist the end of strand wire and make sure that there are no loose wires Do not solder plate the electric wire ends D
13. ike to make the following points As analog devices are sensitive by nature their use should be considered care fully For users of proprietary cables integral with sensors or actuators these users should follow those manufacturers installation requirements Mitsubishi Electric recommend that shielded cables should be used If NO other EMC protection is provided then users may experience temporary loss or accuracy between 10 in very heavy industrial areas However Mitsubishi Electric suggest that if adequate EMC precautions are fol lowed for the users complete control system users should expect accuracy as specified in this manual e Sensitive analog cable should not be laid in the same trunking or cable conduit as high voltage cabling Where possible users should run analog cables separately e Good cable shielding should be used When terminating the shield at Earth ensure that no earth loops are accidentally created e When reading analog values EMC accuracy can be improved out by averaging the readings This can be achieved either through functions on the analog special adapters or through a users program 1 Outline The FX3U 4AD ADP special adapter for analog input hereinafter called 4AD ADP is a special adapter to add four analog input points 1 1 Incorporated Items Verify that the following product and items are included in the package Product FX3U 4AD ADP analog input special adapter Accessories User s
14. ishi Electric dealer from who you purchased your product Applicable standards FX3U 4AD ADP units made in June 2005 or later comply with the EC Directive EMC Directive and UL standards UL cUL Further information can be found in the following manual ies Hardware Manual Manual No JY997D48301 s Hardware Manual Manual No JY997D46001 s Hardware Manual Manual No JY997D45201 s Hardware Manual Manual No JY997D18801 FX3uc D DS DSS Series Hardware Manual Manual No JY997D28601 FX3UC 32MT LT 2 Hardware Manual Manual No JY997D31601 Regarding the standards that relate to the main unit please refer to either the FX series product catalog or consult with your nearest Mitsubishi product provider Attention e This product is designed for use in industrial applications Note e Manufactured by Mitsubishi Electric Corporation 2 7 3 Marunouchi Chiyoda ku Tokyo 100 8310 Japan e Manufactured at Mitsubishi Electric Corporation Himeji Works 840 Chiyoda machi Himeji Hyogo 670 8677 Japan e Authorized Representative in the European Community Mitsubishi Electric Europe B V Gothaer Str 8 40880 Ratingen Germany Caution for EC Directive The analog special adapters have been found to be compliant to the European standards in the aforesaid manual and directive However for the very best per formance from what are in fact delicate measuring and controlled output device Mitsubishi Electric would l
15. it and special adapter mounted on DIN rail or mounted directly using screws 2 Install an expansion board to the main unit For the expansion board installation procedure refer to the following manual FX3u Series User s Manual Hardware Edition Remove the special adapter connector cover j on the expansion board fig A When connecting this product to another special adapter please replace the expansion board in the above description with a special adapter and perform the procedure as indicated 4 Slide the special adapter slide lock fig B of the main unit When connecting this product to another special adapter please replace the main unit in the above description with a special adapter and perform the procedure as indicated Please replace the following procedures similarly 5 Connect the special adapter fig C to the main unit as shown on the right 6 Slide back the special adapter slide lock fig B of the main unit to fix the special adapter fig C 3 Connection precautions Connect all the high speed I O special adapters before connecting other special adapters when they are used in combination Do not connect a high speed I O special adapter on the left side of any special adapters other than other high speed I O special adapters 3 Wiring WIRING PRECAUTIONS Z WARN ING e Make sure to cut off all phases of the power supply externally before attemptin
16. make sure that there are no loose wires Do not solder plate the electric wire ends Do not connect more than the specified number of wires or electric wires of unspecified size Affix the electric wires so that neither the terminal block nor the connected parts are directly stressed Make sure to properly wire the terminal block in accordance with the following precautions Failure to do so may cause electric shock equipment failures a short circuit wire breakage malfunctions or damage to the product The disposal size of the cable end should follow the dimensions described in the manual of the PLC main unit Tightening torque should follow the specifications in the manual of the PLC main unit 3 1 Applicable Cable and Terminal Tightening Torque 3 1 1 Terminal block European type 1 Wire size Wiring to analog device should use 20 22 AWG wire 2 Applicable cable Type Wire size Single wire 0 3 mm to 0 5 mm2 AWG22 to 20 2 wire 2 pieces of 0 3 mm2 AWG22 3 Termination of cable end Strip the coating of strand wire and twist the cable core before connecting it or strip the coating of single wire before connecting it An alternative connection is to use a ferrule with insulating sleeve lt Reference gt Manufacturer Model Caulking tool CRIMPFOX 6 Phoenix Contact Co Ltd or CRIMPFOX 6T F 2 Al 0 5 8WH 1 Old model name CRIMPFOX ZA 3 2 Old model name CRIMPFOX UD 6 Strand
17. manual This manual 1 2 8 9 2 For External Dimensions Part Names and Terminal Layout 5 10 ay 6 fextanaor 7 FI 2 8 a es a 5 2 e y Sol 4 gS S aE S 5 fe E Special adapter p connector cover is removed Weight Approx 0 1 kg 0 22 Ibs DIN rail mounting groove DIN rail DIN46277 Name plate Special adapter slide lock Used to connect additional special adapters onto the left side of this special adapter Special adapter connector cover Remove this cover to connect additional special adapters to the left side Direct mounting hole 2 holes of 4 5 0 18 mounting screw M4 screw Not used when connecting to FX3GC FX3UC Series PLC POWER LED green Lit while 24 V DC power is supplied properly to terminals 24 and 24 Terminal block European type Connect the analog voltage current signal and 24 V DC power supply Special adapter connector Used to connect this special adapter to PLC main unit or special adapter DIN rail mounting hook 10 Special adapter fixing hook 11 Special adapter connector Used to connect communication or analog special adapters to the left side of the 4AD ADP Installation installation uninstallation details refer to the respective PLC User s manual Hardware Edition INSTALLATION PRECAUTIONS WARNING INSTALLATION PRECAUTIONS Make sure to cut off all phases of the powe
18. o not connect more than the specified number of wires or electric wires of unspecified size Affix the electric wires so that neither the terminal block nor the connected parts are directly stressed Make sure to properly wire the terminal block in accordance with the following precautions Failure to do so may cause electric shock equipment failures a short circuit wire breakage malfunctions or damage to the product The disposal size of the cable end should follow the dimensions described in the manual of the PLC main unit Tightening torque should follow the specifications in the manual of the PLC main unit 3 1 Applicable Cable and Terminal Tightening Torque 3 1 1 Terminal block European type 1 Wire size Wiring to analog device should use 20 22 AWG wire 2 Applicable cable Type Wire size Single wire 0 3 mm to 0 5 mm2 AWG22 to 20 2 wire 2 pieces of 0 3 mm2 AWG22 3 Termination of cable end Strip the coating of strand wire and twist the cable core before connecting it or strip the coating of single wire before connecting it An alternative connection is to use a ferrule with insulating sleeve lt Reference gt Manufacturer Model Caulking tool CRIMPFOX 6 Phoenix Contact Co Ltd or CRIMPFOX 6T F 2 Al 0 5 8WH 1 Old model name CRIMPFOX ZA 3 2 Old model name CRIMPFOX UD 6 Strand wire single wire Stick terminal with insulating sleeve Insulation sleeve Con
19. obtain manuals For product manuals or documents consult with the Mitsubishi Electric dealer from who you purchased your product Applicable standards FX3U 4AD ADP units made in June 2005 or later comply with the EC Directive EMC Directive and UL standards UL cUL Further information can be found in the following manual FX3S Series Hardware Manual Manual No JY997D48301 s Hardware Manual Manual No JY997D46001 s Hardware Manual Manual No JY997D45201 s Hardware Manual Manual No JY997D18801 FX3uc D DS DSS Series Hardware Manual Manual No JY997D28601 FX3UC 32MT LT 2 Hardware Manual Manual No JY997D31601 Regarding the standards that relate to the main unit please refer to either the FX series product catalog or consult with your nearest Mitsubishi product provider Attention e This product is designed for use in industrial applications Note e Manufactured by Mitsubishi Electric Corporation 2 7 3 Marunouchi Chiyoda ku Tokyo 100 8310 Japan e Manufactured at Mitsubishi Electric Corporation Himeji Works 840 Chiyoda machi Himeji Hyogo 670 8677 Japan e Authorized Representative in the European Community Mitsubishi Electric Europe B V Gothaer Str 8 40880 Ratingen Germany Caution for EC Directive The analog special adapters have been found to be compliant to the European standards in the aforesaid manual and directive However for the very best per formance from what are in fact delica
20. oes it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi opportunity loss or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties A For safe use e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN HIMEJI WORKS 840 CHIYODA CHO HIMEJI JAPAN Side B J 997D13901K JAPANESE ra ENGLISH MITSUBISHI
21. r supply externally before attempting installation or wiring work Failure to do so may cause electric shock or damage to the product Z CAUTION Use the product within the generic environment specifications described in PLC main unit manual Hardware Edition Never use the product in areas with excessive dust oily smoke conductive dusts corrosive gas salt air Cl2 H2S SO2 or NO2 flammable gas vibration or impacts or expose it to high temperature condensation or rain and wind If the product is used in such conditions electric shock fire malfunctions deterioration or damage may occur When drilling screw holes or wiring make sure cutting or wire debris does not enter the ventilation slits Failure to do so may cause fire equipment failures or malfunctions Do not touch the conductive parts of the product directly Doing so may cause device failures or malfunctions Connect special adapter securely to their designated connectors Loose connections may cause malfunctions 2 1 Connection to the PLC This section describes the connection method to the PLC FX3U Series PLC is used for the following example For installation method to other PLCs refer to the respective PLC User s manual Hardware Edition Procedure 1 Turn off the power Disconnect all the cables connected to the PLC main unit and special adapter and demount the main unit and special adapter mounted on DIN rail or mounted directly using screw
22. r supply of the FX3S FX3G FX3U Series PLC can also be used 3 4 Grounding Grounding should be performed as stated below e The grounding resistance should be 100 Q or less e Independent grounding should be performed for best results When independent grounding is not performed perform shared grounding of the following figure For details refer to the respective PLC User s manual Hardware Edition Other Other Other PLC equipment PLC equipment PLC equipment Independent grounding Shared grounding Best condition Good condition Common grounding Not allowed The grounding wire size should be AWG 22 20 0 3 0 5 mm e The grounding point should be close to the PLC and all grounding wire should be as short as possible 4 Specifications STARTUP AND MAINTENANCE PRECAUTIONS Z CAUTION e Do not disassemble or modify the PLC Doing so may cause fire equipment failures or malfunctions For repair contact your local Mitsubishi Electric representative e Do not drop the product or exert strong impact to it Doing so may cause damage DISPOSAL PRECAUTIONS Z CAUTION e Please contact a certified electronic waste disposal company for the environmentally safe recycling and disposal of your device TRANSPORTATION AND STORAGE PRECAUTIONS Z CAUTION e The product is a precision instrument During transportation avoid any impacts Failure to do so may cause fail
23. s 2 Install an expansion board to the main unit For the expansion board installation procedure refer to the following manual FX3u Series User s Manual Hardware Edition 3 Remove the special adapter connector cover ji on the expansion board fig A When connecting this product to another special adapter please replace the expansion board in the above description with a special adapter and perform the procedure as indicated 4 Slide the special adapter slide lock fig B of the main unit When connecting this product to another special adapter please replace the main unit in the above description with a special adapter and perform the procedure as indicated Please replace the following procedures similarly 5 Connect the special adapter fig C to the main unit as shown on the right 6 Slide back the special adapter slide lock fig B of the main unit to fix the special adapter fig C Connection precautions Connect all the high speed I O special adapters before connecting other special adapters when they are used in combination Do not connect a high speed I O special adapter on the left side of any special adapters other than other high speed I O special adapters 3 Wiring WIRING PRECAUTIONS Z WARN ING e Make sure to cut off all phases of the power supply externally before attempting installation or wiring work Failure to do so may cause electric shock or damage to t
24. s procedures indicated by CAUTION may also cause severe injury It is important to follow all precautions for personal safety Associated Manuals Manual name Manual No Description FX3S FX3G FX3GC FX3U Describes specifications for FX3UC Series JY997D16701 analog control and User s M l MODEL CODE programming method for Po RAE n 09R619 FX3S FX3G FX3GC FX3U Analog Control Edition FX3UC Series PLC FX3S FX3G FX3GC FX3U FX3UC Series JY997D16601 Describes PLC programming Programming Manual MODEL CODE for basic applied instructions Basic amp Applied 09R517 and devices Instruction Edition FX3S Series JY997D48601 Explains FX3S Series PLC User s Manual MODEL CODE specifications for I O wiring Hardware Edition 09R535 installation and maintenance FX3G Series JY997D31301 Explains FX3G Series PLC User s Manual MODEL CODE specifications for I O wiring Hardware Edition 09R521 installation and maintenance FX3GC Series JY997D45401 Explains FX3GC Series PLC User s Manual MODEL CODE specifications for I O wiring Hardware Edition 09R533 installation and maintenance FX3U Series JY997D16501 Explains FX3U Series PLC User s Manual MODEL CODE specifications for I O wiring Hardware Edition 09R516 installation and maintenance FX3UC Series JY997D28701 Explains FX3UC Series PLC User s Manual MODEL CODE specifications for I O wiring Hardware Edition 09R519 installation and maintenance How to
25. tact area Crimp area ea 9mm 8mm 0 35 E5 0 31 Ley a ee 2 6mm 0 1 14mm 0 55 eE When using a stick terminal with insulating sleeve choose a wire with proper cable sheath referring to the above outside dimensions or otherwise the wire cannot be inserted easily The tightening torque must be 0 22 to 0 25 Nem Do not tighten terminal screws exceeding the specified torque Failure to do so may cause equipment failures or malfunctions 3 2 Power Supply Wiring For the power supply wiring refer to the following manual FX3S FX3G FX3GC FX3U FX3UC Series User s Manual Analog Control Edition 3 3 Wiring of Analog Input For the terminal configuration refer to Section 1 2 gena current Terminal 4AD ADP block var 147k cho 2 al me Po 7 akoa como Using voltage input vor 147K cho i 2509 aa como ae ae 15V 24 e e4 24 Fe 1 I T L m Grounding Ground resistance 100 Q or less VO O ch O Orepresents the channel number 1 Use 2 core shielded twisted pair cable for the analog input lines and separate the analog input lines from other power lines or inductive lines 2 Make sure to short circuit the VD1 and IO terminals when current is input O input channel number 3 24 V DC service power supply of the FX3S FX3G FX3U Series PLC can also be used
26. te measuring and controlled output device Mitsubishi Electric would like to make the following points As analog devices are sensitive by nature their use should be considered care fully For users of proprietary cables integral with sensors or actuators these users should follow those manufacturers installation requirements Mitsubishi Electric recommend that shielded cables should be used If NO other EMC protection is provided then users may experience temporary loss or accuracy between 10 in very heavy industrial areas However Mitsubishi Electric suggest that if adequate EMC precautions are fol lowed for the users complete control system users should expect accuracy as specified in this manual e Sensitive analog cable should not be laid in the same trunking or cable conduit as high voltage cabling Where possible users should run analog cables separately e Good cable shielding should be used When terminating the shield at Earth ensure that no earth loops are accidentally created e When reading analog values EMC accuracy can be improved out by averaging the readings This can be achieved either through functions on the analog special adapters or through a users program 1 Outline The FX3U 4AD ADP special adapter for analog input hereinafter called 4AD ADP is a special adapter to add four analog input points 1 1 Incorporated Items Verify that the following product and items are included in the package
27. ures in the product After transportation verify the operations of the product 4 1 Applicable PLC Model name FX3S Series PLC FX3G Series PLC Ver 1 00 or later from first production FX3GC Series PLC Ver 1 40 or later from first production FX3U Series PLC Applicability Ver 1 00 or later from first production Ver 2 20 or later from first production Ver 1 20 or later from the production manufactured in May FX3UC Series PLC 2004 with SER No 45 The version number can be checked by monitoring D8001 D8101 as the last three digits indicate it 4 2 General Specifications Items other than the following are equivalent to the those of the PLC main unit For general specifications refer to the respective PLC User s manual Hardware Edition Item Specification Dielectric withstand 500 V AC for one minute voltage Between all terminals and ground terminal of PLC 5 MQ or more by 500 V DC main unit megger Insulation resistance 4 3 Power Supply Specifications Item Specification AID conversion 24 V DC 20 15 40 mA for 24 V DC circuit driving power Connect a 24 V DC power supply to the terminal block Interface drivin IVDO ASMA g 5 V DC power is supplied from the internal power supply of power main unit 4 4 Performance Specifications Description Item Voltage input Current input Analog input 0 to 10 V DC 4 to 2
28. y rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi opportunity loss or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties A For safe use e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN HIMEJI WORKS 840 CHIYODA CHO HIMEJI JAPAN