1. Activate License Automatic Activate License Manual Download Manual Help contents F1 Check for Updates About Tobii Studio 4 Inthe Manual Activation Information box you can find the information needed to activate your license You can save that information in a text file by clicking the Save as file button 5 You can then choose between three methods to activate your license a Open your web browser and go to the activation page http StudioHelp tobii org Activate if possible on a different computer and enter the license key machine ID and organization information in the designated fields on the page and click Activate b Send an e mail to support tobil com The e mail should contain the company name license key and machine ID eye tracker ID c Call Tobii support at one of the phone numbers shown in the manual activation window The infomation below is needed to activate your license installation by web mail or telephone License key Machineld Organczation Toba E mail Vanual activation methods T Web http StudioHelp tobii org Activate double click to connect 2 Email support tobii com 3 Phone Tobii support double click for numbers Enter Manual Activation Code Enter the activation code received from Tobii through manual activation se above EEE Close 6 An activation code is obtained from the web page or from support 7 Enter the activation code in th
2. 122 tobii File View Tools ForSight Help Design and Record Replay Visualization Statistics I Select Media Recordings Metric Time to First Fixation v Rows Participant Groups Columns AQls per Media v Media time Os to media end Filter by No Group Selected C wil Calculate by Descriptive Statistics _ Participant Variables Cell format Participant Recordi Date tw P01 RecO1 7 24 2009 9 Time to First Fixation The time from the start of the stimulus display until the test participant fixates on the AOI or AO Group for the first time seconds Read Full Description i P02 RecO2 7 24 2009 12 Time to First Foation IK P03 Rec03 7 24 20091 DrawAngry JPG DrawHappy JPG liv P04 Rec04 7 24 2009 1 DrawAngryEyes neutral eyes DrawHappyEyes neutral eyes iv PoS Rec 05 7124 2003 1 C Loe harassed ee 5 Count buscar Seconds Count ieee Seconds gt ot braced Participant Groups lv POG Rec06 7 26 2009 12 male 0 99 1 25 18 1 06 Rec07 7 26 2009 12 female 0 92 1 42 19 1 07 7 P08 Rec08 7 26 2009 12 young men 0 99 1 25 16 1 08 7 P09 Rec09 7 26 2009 1 young women il P10 Rec10 7 26 2009 1 All Participants 4 0 96 5 1 31 J 53 1 07 Fal DA4 Deo it IMC MANS gt Check Uncheck La Areas of Interest ial emotional face w ia neutral faces Y io DrawAnory JPG ReadingandFaces DrawAngryEyes u V
3. To create a scene using the timeline marker 1 Select the recording you want to use to create the scene and make sure the Scenes pane is visible 2 Drag the timeline marker to the location in the timeline where you wish to set the start of the scene 3 Drag the right handle of the timeline marker to set the end position The red color indicates the section on the timeline that is currently selected The starting and end point can be moved by dragging their respective markers 4 Right click the selection and click Create Scene from Selection 5 The new scene is displayed in the Scenes pane together with the respective recording coverage information indicated by a gray box a fal ge_lage Side2 Texti JPG 14 esau we 00 00 49 607 0 png Dre o u Eia rea ei ct 1 A p e e E erty pl a Rename Delete Del m1 Scenes Set new Scene Image Copy content to all Recordings il Segments Scenes Settings Recording Rec 01 length 00 01 47 791 participant P01 6 Open the Scene context menu by clicking the arrow next to the default scene name 7 Select Rename to change the name of the scene 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 67 and or other countries User
4. 1 Choose the video source by selecting a camera from the Video Source drop down list 2 Ifthe device has more than one input e g S video and composite specify the input you want to use for the video recording by selecting it in the Inputs drop down list 3 Choose the codec you want to use to convert and or compress the video signal during the recording by selecting a codec from the Video Codec drop down list The choice of codec will impact the video quality file size and CPU load during recording For most purposes the Microsoft Video 1 codec is recommended 4 Click the Settings button to set the temporal quality ratio of the video compression The higher the quality ratio the better the video quality will be but the more CPU resources will be consumed 5 Click Edit to enable or disable codecs from the list Select the codec from the disabled list and click the left direction arrow to add the codec to the Video Codec drop down list Do the opposite to remove a codec 6 Click the Preview box to preview the video streamed from the device 7 Select the Record user sound check box to enable user sound recording and choose the microphone used to record the user form the Audio Source drop down list 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 159 and or other countries User Manual Tobii Studio 2 X
5. To enable live viewing 1 Select the Enable live viewing check box to enable the local live viewer If this option is unchecked you will not be able to open the local live viewer window Select the Enable remote viewing check box to use Studio Logger Live Viewer If this option is unchecked you will not be able to view the live viewer window in the Remote Desktop pane of Studio Logger When remote viewing is enabled you can choose to allow Tobii Studio to connect to several Studio Logger clients several computers running the Studio logger Select the Use multicast check box to create a multicast IP address and enable multicasting The IP address is displayed in the Multicast IP address field Select the Sound and Camera image check boxes to enable broadcasting of the user camera image and sound to Studio Logger 11 2 2 Eye Tracker browser and hardware settings The Eye Tracker tab allows you to select and connect to the eye tracker connected to the Tobii Studio computer as well as configure the connection to old eye tracker models update the eye tracker firmware and configure the X Series Eye Tracker setup Global Settings Screen and Video Capture Eye Tracker Calibration Fixation Fitters Recording Miscellaneous Cant find your eye tracker Test selected eye tracker Delete selected eye tracker X Senes Contig Tool Upgrade eye tracker Fyetrackers of older models can be added manually Use 127 0 0 1 as ho
6. User Manual Tobii Studio 2 X To randomize the presentation order between two or more media elements 1 Right click the media elements you want to randomize 2 Select Randomize on the context menu 3 Repeat steps 1 and 2 for the other media elements you wish to randomize 4 Or right click the media timeline and select Randomize all to randomize all the media elements on the timeline To remove the randomization 1 Right click the media element 2 Click Randomize to remove the check mark The media is now deselected from the randomization procedure Notes If you only select randomization of one media element no randomization will take place If you choose to quit a recording while you are performing a test the next recording will use the next sequence for the media presentation 4 1 4 1 Tobit Studio Latin Square implementation The Randomize feature uses a Latin Square method to construct x number of sequences of the presentation depending on n number of media selected to be randomized If n is even x n and if n is odd x 2n Each Latin Square sequence x is translated into a recording To conduct a fully counterbalanced study the number of recordings must be equal to x or a multiple of x If not enough participants can be tested the study is still pseudo randomized but not fully counterbalanced Latin Square procedure lf the number of treatments is even then the first sequence of the Latin Square is calculated as follow
7. 4 Click OK to accept the settings and close the dialog box Extended desktop dual screen setups are often used to enable a test leader to control a test using one display while presenting the stimulus to the test subject on another To configure an extended desktop dual screen setup 1 In the lower left corner of the Design and Record tab click the Identify button Text is displayed on the screen where the presentation will be displayed 2 Press ESC to return to the Design and Record tab 3 If you wish to change the display click the Presentation screen drop down list and select Display 1 or Display 2 The stimulus will be presented on the display that you select 4 Make sure the local Live Viewer is enabled Click the Setup icon on the Design and Record header and select Settings 5 Towards the bottom of the Screen and Video Capture tab select Enable live viewing Click the Setup icon again but this time click Show Live Viewer 7 The Live Viewer window opens on the primary monitor Drag the window to the display that is used to monitor the recording see section 11 1 2 of this manual pages 156 158 to find out more on how you can configure your system to support a dual screen setup D To check if the user camera and user sound are enabled disabled 1 Click the Setup icon on the Design and Record header and select Settings 2 Under the Screen and Video Capture tab select the Record user camera and Record user so
8. 64 tobii Note If the start and stop events are the same type of event for example a LeftMouseClick the stop point event Next LeftMouseClick has to be selected In this example segments will be created between all left mouse clicks 5 4 2 Generating segments manually Go to the Replay view and choose the test you want to create segments for To create a segment manually 1 Select the recording you wish to use to create the segment and make sure the Segments pane is visible 2 Drag the timeline marker to the location on the timeline where you wish to set the start of the segment 3 Drag the right handle of the timeline marker to the end position The red color indicates the section on the timeline that is currently selected Side Textil JPG Sides J Te_ C Ins H PB P EDrE P BB Drlin_ Ul cs ha ia ae a ann Segment 2 fea Segment 1 gt 2 Rename F2 Delete Del D on Loop Export to AVI ents Scenes Settings Recording Rec 01 length 00 01 47 791 participant P01 4 Right click the selection and select Create Segment from Selection 5 The new segment is displayed in the Segments pane Repeat the steps to generate more new segments To edit an existing segment 1 Click the Down Arrow located to the right of the segment name the segment menu arrow 2 Select Rename to change the segment s name or Delete to delete the segment from the recording 3 When ho
9. Tobii heat map calculations using fixation count for Absolute and Relative duration the calculations are the same however instead of using the number o fixations as values we use the fixation duration or fixation duration media viewing time respectively 1 The fixations are added according to their X and Y coordinates and the cubic hermite spline value distribution is applied to each fixation count x location in pixels 2 If different fixations fall in the same location their values are added This affects the height of the distribution but not the kernel which is kept constant at 100 pixels See images above and below count x locationin pixels 94 tobii count x location in pixels 3 If their distributions overlap the overlapping values of the distribution are added count xlocationin pixels count x location in pixels 4 The maximum value setting Display settings field for the color interpolation is set to the highest fixation value For example if the highest fixation count in the data is 3 this value will be set by default as the maximum color value this value can be viewed in the heat map legend and in the Display settings of the heat map settings 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 95 and or other countries User Manual Tobii Studio 2 X
10. User Manual Tobii Studio 2 X If the Web Groups tool is used to group two or more URLs the group and not the URL will become a unique media element Total Fixation Duration Measured in seconds LAO A J Fixations on media size indicates duration QeeGo9M O 00 J0 AO Gn cordings mean Total Fixation Duration on AOI B in Media 1 9 4 6 1 N value This statistic describes the N value used to calculate other descriptive statistics such as the mean and standard deviation In the current metric it represents the number of recordings and is calculated as follows Row settings When recordings are selected as table rows the N value will always be equal to 1 If participants are selected as table rows the N value will be equal to the number of recordings that participant has made with the same media element If participant groups are selected as rows then the N value will be equal to the number of recordings included in the group Summary columns In the AOI media summary columns the N value represents the number of recordings x the number of AOls included in a single media element In the AOI group summary columns the N value represents the number of recordings and follows the rules described in the previous paragraph row settings In the AOI metric summary columns the N value represents the number of recordings x total number of AOls i e all AOls included in all media elements 132 tobii 9
11. cspline The specific function of the polynomial that is used is t2 3 2t represented by the blue line in the graph below The orange line represents the fixation point and thus the maximum color value Heatmap Colour distribution Cubic Hermite Spline polynomial y t2 3 2t 1 1 P os W Linear l interpolation o E 0 JE 100 pixels The radius of the function is fixed and set at 50 pixels corresponding to a total kernel of 100 pixels This fixed kernel was calculated to reflect the human visual field i e the fact that the human eye has the highest visual acuity at the fovea and that the acuity decreases as we move away from this spot on the retina For 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 93 and or other countries User Manual Tobii Studio 2 X example when we focus on a word in a text we are able to read the word and its immediate neighbors but not words a few centimeters away Since the kernel is fixed and set in pixels Tobii heat maps are dependent on screen resolution and less representative of the individual s foveal vision if the participant varies his distance greatly to the stimulus The current kernel size is optimized for the Tobii T Series Eye Trackers standard screen resolution 1280x1024 and the typical distance from the participant to the eye tracker screen 64 cm
12. Click the Preview Test button located next to the red Start Recording button at the bottom of the window to preview the test starting with the first element If you wish to start previewing the test from a specific element and onwards right click that element on the timeline and select Preview Test from the context menu 2 You can press the F10 key to override the settings and move on to the next media element or press the ESC key to end the preview To preview individual media elements 1 Right click the media element 2 Select Preview Element from the context menu 3 Press the ESC key to end the preview Note You can only preview instruction image movie and PDFs individually 4 1 7 Creating new tests Tobii Studio projects can contain multiple tests These tests can be used to present different tasks to the same participants or to present the same media in different orders useful for factorial design experiments 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 43 and or other countries User Manual Tobii Studio 2 X To create a new test 1 Click Add New Test after either having clicked File on the menu bar or having clicked the Test drop down button the folder symbol which is in the upper left corner and displays the current test s name 2 Type a name for the new test in the Test Name field and
13. Clinically and pediatrician recommended for babies with allergies sensitive skin After 3 seconds the animated heat map will display accumulated gaze data from the start of the recording to 3 seconds micals and moisture have diaper rash ue high absorbency natural blend cotton S cotton soft extra thick gel free protection aby s sensitive skin The chlorine free materials and t polymers is non toxic and non irritating Clinically and pediatrician recommended for babies with allergies sensitive skin If you are not satisfied with the baby leakage protection you will get your money back Read more abo Start 00 00 00 000 Length 00 00 02 990 Save time settings 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 103 and or other countries User Manual Tobii Studio 2 X e Select Sliding window interval length to limit the display of gaze data to a pre determined time interval throughout the playback This interval is set by clicking the field and typing a value in seconds For example the red rectangle in the image below represents the gaze data interval that is displayed on the heat map during the 2nd second of playback with the Sliding window interval length set to 1 second f icals and moisture t gt di ash ique high absorbency natural blend cotton vides cotton soft extra thick g
14. In the Manage Participants dialog box under the Participants tab click Auto Generate 2 Now enter the number of participants you wish to generate and click OK 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 45 and or other countries User Manual Tobii Studio 2 X 3 The participants are displayed in the participants list and are automatically named Pn x to Pn where n is the total number of participants and x is the number you generated You can add up to 500 participants at a time with this feature To edit an existing participant 1 Inthe participants list double click a participant or click the participant and then click Edit 2 You can change the participant name or the independent variable values in the Edit Existing Participant dialog box 3 Click OK to accept the changes 4 2 2 Creating independent variables Participant independent variables and values can be generated in two different ways in Tobii Studio You can directly create the variable name and values in the Manage Participants dialog box or by adding a Questionnaire media element to the test and letting the participant select the values In the latter case the variable name entered in the Question Setup is the variable and the possible answers are the values of which the participant can only select one for each question To add a new i
15. Key Press E Show Mouse Cursor To set the Movie element transition during the presentation select one of the following options e Movie end The duration of the media element presentation is set to the end of the video playback i e the next element on the timeline is shown when the video ends e Mouse click The video will be shown until the mouse is clicked This can be done by the test participant or the test leader Thereafter the next media on the timeline will be shown e Key press The video will be shown until any key on the keyboard is clicked This can be done by the test participant or the test leader Thereafter the next media on the timeline will be shown Select the Show Mouse Cursor check box if you wish to display the mouse cursor on the screen during presentation of the video During the test the video is presented in actual size but limited to the eye tracker s screen resolution For example if you are using a Tobi T60 or T120 Eye Tracker the maximum video size is 1280x1024 pixels while with a Tobii T6OXL Eye Tracker the maximum is 1920x 1200 pixels Videos larger than the eye tracker s screen resolution will be cropped during the media element s presentation Use a video editing application such as Adobe Premiere or VirtualDub to resize a video A video media file generally consists of a video data package containing a video header block and a video data block This type of file format is often called a
16. Tobi Demo Project File View Tools ForSight Help Design and Record Replay Visualizations Statistics Print Advertisements Export AOI Groups Web Groups Gaze Plot Cluster Bee Swarm AO Tool Diapers 01 jpg Diapers 02 jpa I fixationcross jpg m Juice 01 jpg Juice 02 jpa f Newspaper Black and White jpa entle for the IP Newspaper Color jpa arabe ensitive skin Welcome 19 31 secs Media List ive skin add the chemicals and moisture Filter by No Group Selected X you have diaper rash Parti M A Name C Samp ran s unique high absorbency natural blend cotton Rec7 95 a06 f cotton soft extra thick gel free protection V Recs Es 5 Sensitive skin The chlorine free materials and j orbent polymers is non toxic and non irritating Clinically ORec5 Mi 90 po i gt tested and pediatrician recommended for babies with allergies s a Ores Mi 94 and sensitive skin Rec3 85 Q Rec2 69 QReci 87 Check Uncheck Name Recordings Areas of Interest Start 00 00 00 000 lt Length 00 00 06 033 lt E Save time settings Recordings Areas of Interest Timeline Settings AOI Overlay Setting The Visualization tab is divided into three main areas e Visualization header Contains the test menu the export menu the AOI groups tool the Web Groups tool AOI tool and the different visualization tools e Selection pane Th
17. Tracker TET Server on the computer single computer setup The TET Server installation file can be found on the Tobii Studio CD To install TET Server 1 Open the Tobii Studio CD folder gt Drivers and Utilities gt 1750 x50 2150 9 Double click TETServer 2 9 16 Windows XP or 2 9 18 Windows Vista to run the installer package 3 Follow the on screen prompts and instructions to complete the installation Note TETServer 2 9 16 Windows XP and 2 9 18 Windows Vista are not compatible with Windows 7 1 2 Installing Tobii Studio To install Tobii Studio you need the Tobii Studio CD and a software license key The license key is used to activate Tobii Studio after it is installed on the computer Tobii offers single user and multiple user licenses A single user license includes a key for each copy purchased A multi user license includes one key with entitlement to install the software on multiple workstations License activation can be conducted when first running Tobii Studio or up to 5 days later if you are not able to connect to the Internet during the installation The Tobii Studio license key is located inside the Tobii Studio CD cover Use manual activation if you have problems activating your license or do not have an Internet connection To install Tobii Studio 1 Insert the Tobi Studio CD in your computer 2 Open the Tobii Studio CD folder 3 Double click TobiiStudio_ installer exe represents the Tob
18. allows you to locate and navigate quickly to different parts of the recordings The filter will display events that contain the text you typed To filter events 1 Select the recording you want to work with from the Recordings list 2 In the filter field located in the upper part of the Events list type the first letters you want to start filtering by 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 63 and or other countries User Manual Tobii Studio 2 X 3 All other events in the Events list and bookmarks in the timeline that do not satisfy the filter criteria will be hidden 4 Click the event you wanted to locate and the timeline marker will jump to the point on the recording when that specific event occurred To turn off the filter delete the text in the filter field 5 4 Creating video segments A segment is a section of a Tobii Studio recording The start and end point of the segment can be set manually using the timeline marker or automatically using events Segments are commonly used to create video exports of the gaze replay These videos can then be viewed with external media players Segments can also be used to create scenes in this case the segment determines the section of the recording that contains the relevant gaze data to create visualizations or calculate eye tracking metrics 5 4 1
19. neutral eyes l v r DrawHappy JPG ReadingandFaces V DrawHappyEyes 7 neutral eyes gt T DrawSad JPG ReadingandFaces no E EL Check Uncheck Z Show Not on AOI Update Manual Auto The Table columns headings are composed of 4 rows that follow a specific hierarchical order The first row displays the metrics columns the second row shows the media columns the third row displays the different AOI and or AOI groups columns and the fourth row shows the descriptive statistics columns The row s title is displayed in the first column of the table The heading and content of this column changes according to the settings in the Row list box in the Statistics toolbar The last row of data in the table displays a summary of the data from all the table rows Above the table you can view a brief description of the metrics selected to generate the tables The Table properties are available when you click the Table pn button In the toolbar located at the top of the Statistics workspace you can customize which descriptive statistics you want to display in the table the option to show participant variables and the table cell format To select the descriptive statistics 1 Click the Calculated by button The Descriptive Statistics list is displayed 2 Select descriptive statistics to include in the table by selecting the N Mean Max Min Sum Median or Stdev check boxes Click
20. the quality of the recording as a percentage and the name of the participant However you can display more information and choose the information column to sort the recordings by To display more columns of information 1 Right click anywhere in the recordings list 2 Select Show in the context menu 3 Select the information you want to display on each row To select which column to sort by 1 Right click anywhere in the recordings list 2 Select Sort by in the context menu 3 Choose the data you want to sort the recordings in the list by 84 tobii 4 Click the respective column heading to change the sort order Types of information e Name ID of the recording e Date Shows the time and date when the recording was performed e Duration The duration of the recording in seconds e Color The color used to identify the recording on the timeline and in the visualizations on the Visualization tab e Samples The quality of the recording is calculated using the number of eye tracking samples that were correctly identified 100 means that both eyes were found throughout the recording 50 that one eye was found for the full recording or both eyes during half the time Note that the eyes cannot be found when a person is looking away from the screen this will result in a lower percentage If the test is performed so that the participant is asked questions during the recording and occasionally looks at a test leader an alterna
21. 01 06 000 1 00 0 17 00 a m o gi ili Events User Cam H Segments Scenes Settings Recording Rec 09 length 00 01 23 972 participant P09 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 61 and or other countries User Manual Tobii Studio 2 X In addition to these automatic events you can also generate your own log events by using the coding scheme feature in Tobii Studio These events such as a participant clicking a link on a web page will also be shown in the Events list During the playback of the recording you can use these events to mark the sections in the recording that you find of interest or are more relevant to your study You can then use the bookmarks on the timeline or Events list to find those sections quickly For example you can use the user camera to record the reactions of the participants to the stimulus presentation and use the coding scheme to log the parts in the recording where the participant was confused distracted or engaged Later you can extract eye tracking metrics from these sections of the recording and compare the eye movement activity during the three behaviors You can also manually log events which can be useful when creating segments Segments can be used to create movies or scenes and the Events list can be filtered to only show specific events in the l
22. 1920 x 1200 1080p for the Tobii T6OXL Eye Tracker 4 Once your screen resolution changes you have 15 seconds to confirm the change Click Yes to confirm the change click No or do nothing to revert to your previous setting 5 To improve the graphics card performance and reduce the hard disk load select High 16 bit for Color Quality For studies that require higher color quality use a computer with high performance and contact Tobii Support for recommendations 6 Click OK to accept the changes and close the Control Panel Windows 7 1 Open the Start menu on your computer and select Control Panel 2 Inthe Control Panel find the Appearance and Personalization category and click Adjust screen resolution 3 Click the Display drop down list and select the display you want to set up 4 Click Resolution and make sure it is set to 1024x768 or 1280x1024 for the Tobi T60 and T120 Eye Trackers and 1920 x 1200 1080p for the Tobii T6OXL Eye Tracker 5 Once your screen resolution changes you have 15 seconds to confirm the change Click Yes to confirm the change click No or do nothing to revert to your previous setting 6 To improve the graphics card performance and reduce the hard disk load select High Color 16 bit for Color Quality Click Advanced settings and then click the Monitor tab Under Colors select High Color 16 bit and then click OK For studies that require higher color quality use a computer with very good performance an
23. 2 Drag the Opacity marker between Transparent and Opaque to adjust the opacity of data representation 3 Type or select the value for the gaze trail duration in seconds in the Trail Duration field 4 Click the Overlay color box to open a color palette and select the desired color of the gaze overlay To select which sound is played during the playback of the replay 1 Select Replay On to hear the test audio during playback 2 Select User Camera On to hear the audio from the user camera a microphone must be connected to the Tobii Studio computer and enabled during the recording 5 2 Performing a Retrospective Think Aloud recording Retrospective Think Aloud RTA is a commonly used technique in which the test leader follows up an eye tracking test with an interview during which the subject explains his her behavior during the test Tobii Studio s RTA feature allows you to conduct and record an RTA interview while showing a playback of the original Tobii Studio recording to the subject Or it can also be used as an external sound recorder replacement The RTA recordings will be available in the recordings list in the Replay view for playback and further analysis To make an RTA recording in Tobii Studio 1 Connect a microphone to the computer and then go to the Tools menu on Tobii Studio s menu bar and click Settings 2 On the Screen and Video Capture tab enable user sound recording by selecting the Record user sound check
24. 50 Dna The window while under the Replay tab is divided into three main areas e Replay header Contains the Test Generate Export and RTA buttons e Recordings pane This is where you can select and delete recordings view a list of the different events Events and see the user camera recording User Cam e Replay pane This is where you can view playback of the stimuli and recording of the participant s gaze view the recording timeline control the playback create and edit segments and scenes and change viewing settings To play back a recording 1 In the Recordings pane click the recording you wish to view 56 tobii 2 Inthe lower left corner of the Replay pane click the play button to start playback of the recording Use the rewind forward stop and pause buttons to control the playback 3 While paused click the RIGHT and LEFT ARROW keys on your keyboard to move forward or backwards respectively frame by frame 4 Jump to different sections of the recording by dragging the marker on the Replay pane timeline clicking the desired location or clicking an event in the Events list in the Recordings pane 5 1 Playback settings The complete test session recording can be viewed at any time with gaze data superimposed The Replay tab is a flexible tool that allows you to customize different aspects of the recording playback and analysis detail 5 1 1 Customizing the recordings list I
25. 9 4 Eye tracking metric definit onS sissioni iinn aae EE ieee ee ee eee 125 2AT Descipive stat UCS corssier a ere re ee near T ERR 126 9 4 2 Time to First Fixation SecondS esessessssssisrsresisrerurnsrerunnnnnrnnnsnurunnnnunnnnnnunnnnnnunnnununnnnnnnnnnnnnnnnnnennn nae 126 9 4 3 Fixations Before COUNt cccssssssecsessecsessesseecsessessesseeseeseeseessesessessesseeseeseesaeseeseessaesersarsesnsonssnseaseas 128 GAA First Fixation Duration SecondS sessesssessernsesrsrusrennrunnsrnrunnnrnnnsnnrunnennrunnnnrunnntununnnnnnnnnnnnnnnnnnnnnnnne 129 9 45 Fixation Duration SECONQS ssssssiirsissonsnssiinoisnininnar hia panara Raa araia A ab erai a aaraa ia niaaa 130 9 4 6 Total Fixation Duration SecondS s esesessssesrsrerusrrsrerunrnrnrnsnsrurunnnrnnnnnnnunnnnunnnnnununnnnnnnnnannnnnnnnnnnn nae 131 9 4 7 Total Fixation Duration Zeros SCCONS cccesscesessesessssescecceecaceecacsecarsccecsceesaceecaesecatsecaraneetaneneaners 133 948 Fiaton Count COUN ee ee ne ee ee ee 133 9 4 9 Fixation Count Zeros COUN t ccesescssessssesssessscsscecsesecaeeecaescsecscsecaesecansesassesavancesaueesansesatesataueetanseeanens 134 9 4 10 Visit Duration SeCONAS dusss a etter aE EAEE i cet 134 9 4 11 Total Visit D rahon SecgndS ssassn aoaaa aiaa EE 135 9 4 12 Total Visit Duration zeros SecondS esessesesessseesesescesssceceecsceecaeeecassececsesecaueecacesatsesaraneetaneeaters 137 9 4 13 VSE COUNT COURE eet
26. Calibration Grid i USB Network dapis i VGA DVI capture Tobii Studio computer with a VGA DVI output VGA DVI video capture card Primary Screen Live viewer ae Before adding the Scene Camera media element to the test make sure the hardware is set up properly The video source needs to be connected to a video capture card FireWire or USB port on the computer where Tobii Studio is running Please refer to the system recommendations document available for download at www tobii com or contact Tobii Support for information on recommended video capture cards and setups 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 33 and or other countries User Manual Tobii Studio 2 X To name the media element 1 The software uses Scene Camera Element as the default name You can change it by clicking the Element Name field deleting the existing text and typing a new name To set the video recording source and properties 1 Choose the video source by selecting a device form the Video Source list 2 If the device has more than one input e g S video composite specify the input you want to use for the video recording by selecting it in the Inputs list 3 Choose the codec you want to use to convert and or compress the video signal during the recording by select a codec f
27. DrawHappy JPG All AOIs All AOTs N Mean Sum N Mean sum T Count Seconds Seconds Count Seconds Seconds Recordings Rec 01 2 1 36 2 72 2 0 98 1 96 AOI Group Summary Each cell in the AOI Group Summary columns contains the descriptive statistic value for an AOI group calculated for all the selected media The cell value calculation also depends on the Row option selection The data is displayed using the following column hierarchal order metric gt All media groups the data from all the selected media gt AOI Group gt Descriptive Statistics Example below 2 images DrawAngry JPG and DrawHappy JPG 2 AOI Groups emotional face and neutral faces Row option Recordings Time to First Fixation All Medias emotional face neutral faces N Mean Sum N Mean Sum T A Count Seconds Seconds Count Seconds Seconds Rec 01 1 0 85 0 85 1 0 30 0 30 AOI Metric Summary Each cell in the AOI Metric Summary columns contains the descriptive statistic value for all AOls and all the media The cell value calculation also depends on the Row option selection The data is displayed using the following column hierarchal order metric gt All media groups the data from all the selected media gt All AOls groups the data from all AOls present in each media gt Descriptive Statistics Example below 2 metrics Time to First Fixation and Fixation Duration 2 images DrawAngry JPG and DrawHappy JPG 2 AOls DrawAngryEyes and neutra
28. Explorer Browse to the appropriate project folder Double click the project folder to open it in Windows Explorer Click the database file db3 and then click Open to add it to the project list You can now open the project within the Tobii Studio Project Library ae YS 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 15 and or other countries User Manual Tobii Studio 2 X Note When you link a project to the Tobii Studio Project Library only a link is created in the library while the project archive tests stimuli and recording database remains in its original location The project location is listed in the Tobii Studio Project Library s project list under the Path column 2 4 Exporting and importing projects Projects can also be exported as a single compressed file nas and imported into another copy of Tobii Studio running on a different computer These files contain all the information and elements included in the original project and once the file is imported into another Tobii Studio workstation it can be used to perform the same tests as the original To export a project 1 Start Tobii Studio 2 Open the project to be exported for details see section 2 2 of this manual page 15 3 On the File menu select Export Project Archive The Export Project dialog box will open Export Project Archiv
29. Filtering allows you to restrict the data used to calculate the eye tracking metrics to a group of participants Each filter is defined by either one independent variable or a combination of independent variables 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 115 and or other countries User Manual Tobii Studio 2 X Use the Filter by drop down selection button located on the top of the Recordings list to filter the recordings according to participant groups By default the button will display No Group Selected if no groups have been selected To select a filter 1 Click the Filter by drop down selection button This opens the Participant Groups list Participant Groups Parid No Group Selected f 1 male Fa x T d Filter by w PO iw P02 female ff o El gt young men Fa v POS young women If POS E Create new participant group i P05 i y POG RecO6 Fie6f2009 12 w PO RecO 7 26 2005 12 Ei POS Rec O68 76 2009 12 iv POS Rec OS 7262009 1 Ed P10 Rec l 762009 1 El T rity 7 a CheckUncheck 2 Under Participant Groups select an existing group by clicking the group or create new group by clicking Create new participant group 3 When a participant group has been selected the list of recordings will be updated automatica
30. Preview Media aMedia xxx TIME HOC KOCHI KOK KXXXXX XXX Participant Filter All Heatmap max value indication Use curent set value Recalculate max for each media OK Cancel 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 101 and or other countries User Manual Tobii Studio 2 X 7 7 2 In the Output folder field type the location where you wish to save the images Alternatively you can click the Browse button and browse to the folder where you wish to save the images Click Advanced to select the information to include in each image file name and sub folders Specify the export scope by choosing Only export current media Export from all medias in the current test or Export from all medias in all tests in current project Specify if you want to batch export visualizations based on different participant groups participant filters Tobii Studio exports one visualization for each selected group Choose the time interval Time settings for the export Select Use current time to export the visualization using the interval determined by the timeline markers in the visualization pane Select Use max time interval of Media to include all the possible data for the media element Select the information to be included in the visualization legend Disable the legend by clearing the Show legend che
31. Quadro FX570 256MB T5400 NVIDIA Quadro FX 1600M 256MB M6300 NVIDIA Quadro FX 2700M Graphics with 512MB M6400 ATI ATI FireGL V3300 128MB Windows Vista appearance settings optimized for better performance In addition to the stimuli display offsets you can also encounter video and sound capture offsets that are caused by the latency between image recording or capture e g at image sensor exposure when using a camera and the Tobii Studio timestamps 13 1 Recommendations When designing an experiment it is always good practice to test both experimental procedure as well as the equipment you will be using to perform the tests If you are conducting eye tracking experiments that require high timing precision we strongly recommend testing your eye tracking setup with the stimuli you will be presenting as well as conducting a pilot test to assess the quality of the data Tobii Studio timing offsets can be reduced by following these recommendations e Optimize your computer hardware by using Tobii recommend components For an overview of the configurations tested by Tobii Technology see Table 6 on the next page For a more detailed list of Tobii Eye Tracking Recommended components see the system recommendations for Tobii Studio and TX series Eye Trackers e The computer running Tobii Studio should have the least number of processes running in the background This means that you should disable or uninstall any unnecessary programs that m
32. ReadingandFaces 5 7 Demographics InstructionsRea Readingi Questionnaire El Instruction Ele Colosseur ies bom Ganin 4am noun the fodowing e aeree ier epte rme z Samiaan nisa DOSNT eg qVeston 7 the text em iroda meb pae ara _ io onomasatog as ghee met n the next side maa at r rdar Se nt a Who was the ruler 20 tobi Tobii Studio tests are composed of media elements that are organized along a presentation timeline A large number of media types are available images PDF documents screen recordings websites movies physical objects using a scene camera external video and instruction stimuli This facilitates studies in a range of different research fields Media is added to the test by dragging the media element from the media toolbar to the timeline For example you can quickly place a series of pictures AVI movies or add a screen or web recording in the same test except when using external video and scene camera media For more information on Tobii Studio media limitations please see chapter 12 of this manual page 165 E Prime Tobii Studio 2 18 ee a Drag and drop preferred media here To add a media element to the test 1 Drag the media element icon to the test workspace timeline indicated by the gray arrow in the user interface The media setup dialog box opens 2 Setup your element by changing the settings in the media setup dialog box see information on how to
33. Recording to show the test and record media and eye tracking data 12 The recording concludes when all the media elements have been presented Note You can override the media settings with F10 and move to the next stimuli or stop the recording completely with ESC 13 Once the recording has ended you are ready to move to the Replay tab and analyze the recording 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States D5 and or other countries User Manual Tobii Studio 2 X 5 Replaying and Editing Recordings After the recordings have been completed you are ready to analyze the data The Replay tab in Tobi Studio provides you with a way to dynamically view the eye tracking recording perform a basic qualitative analysis of a participant s behavior during the test record participant interviews Retrospective Think Aloud code events and edit recordings for further analysis During replay the gaze path video is overlaid on the stimuli regardless of the media type The Replay tab also integrates tools to create media elements scenes from video stimuli and dynamic web content e g Flash These scenes can then be used to produce visualizations on the Visualization tab and eye tracking metrics descriptive statistics based on Areas of Interest on the Statistics tab Spotify Tobii Studio 2 1 12 File View Tools ForSig
34. Settings To select a media for analysis simply click the media row in the media list and click one of the visualization icons 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 81 and or other countries User Manual Tobii Studio 2 X 7 1 1 Grouping web pages The Web Groups button on the Visualization header opens the Web Group Tool dialog box This tool is used to group different web pages for analysis Web pages can either be grouped using predefined criteria such as by URL Size ID and Name or can be grouped manually When the pages are grouped the gaze data from all the pages in the group is aggregated and displayed on a single page selected to represent all the pages This page is called Group Image When grouping images make sure that all pages in the group contain the same data or that they have the same content for the areas that are important for analysis Once web groups are created the groups will appear in the media list as a single item This item can then be used to create visualizations and statistics 7 1 1 1 Automatic grouping using preset criteria When you perform a web recording each page visited is recorded automatically by the software By default when you open the Visualization tab for the first time after making a recording the web pages are grouped by Content I
35. This process is conducted by applying a fixation filter to the data Fixation filters are responsible for how fixation data such as fixation count duration and location is calculated This data in turn affects how gaze plots heat maps clusters and eye tracking metrics are inferred Fixation identification is mostly a mathematical and statistical process that attempts to describe how the eye moves Despite the accuracy and flexibility of some of the algorithms the limiting factor is that there is no precise definition for the start and end of a fixation and thus the identification process still remains partly subjective Therefore the best identification validation process is still to perform a test where you compare the fixation filter data with an observer s subjective impression on the position and duration of the fixations If you do not have any particular requirements in your study regarding how fixations should be defined use Tobii Studio s default fixation filters setting Tobii Studio uses two types of fixation filters to group the raw data into fixations Tobii Fixation Filter and ClearView Fixation Filter The basic idea behind these algorithms is that if we know the eye tracker sample rate and measure the distance between neighboring gaze data points we can calculate changes in the eye movement velocity for all eye movement samples During this process the raw data points are assigned to the same fixation if the velocity remains
36. Tou ra Dagang Sp Tou ie Dagang Soe You are apg ai Tou we buang do Bipa aa ipo corer Bhp ease Spee core _ hiipii pab oan en memana 1k fae ihi mi A _ hipriseea pai conien Yar _ hipriivapo coe Tor se byrg pe hipriies poi oomini hipi paip conien hpr ewe poy comian PARE free DPOF conan ioe i een E on ern HET 1 Y fT nei 17A ene Oe aac rec Py DORA daa y Paii LELLES PPI nnn ass 105001 Panta 1 err ns 1a 15h T5 bi 1 fel LS 12i Fal TAS 1i THa 15a TAk Ti Taha Tita TH Fae indem Set Me Greun mage OK 4 Add the frame by dragging it to the new group 5 Repeat steps 3 4 to add more frames to the group Before adding another frame to the group you can compare its content with the frames in the group Select one frame in each list and use the web page preview to check if the content is the same 6 Set the web group background image by selecting the web frame and clicking the Set As Group Image button 7 Click OK to accept the changes and wait while Tobii Studio saves the changes 8 Each group is displayed in the media list as a single media item 7 2 Selecting recordings You can select the recordings by selecting the check boxes in each row of the Recordings list By default the recordings list displays the name of the recording the color used to identify the recording on the timeline and in the visualizations
37. User camera settings section 5 Select the user camera opacity and size 6 Select the codec you want to use to produce the video and type or select the frame rate of the video export 7 Click OK to initiate the batch export A dialog box will appear when the export has completed When you click OK the folder containing the videos will be opened 5 5 Creating scenes from dynamic content Unlike segments which are mainly used for exporting the recording scenes are primarily used to prepare the recording for the Visualization and Statistics tab Recordings need to first be divided into scenes in order to produce visualizations and to extract AOI statistics from media elements that display dynamic content i e movies screen recordings external video scene camera and web pages containing flash elements A scene contains two elements a static image set by the user that is used as the background for the visualizations and the gaze data from the section of the recording where the image was extracted After being created each scene will be available in the media list of the Visualization tab and in the media browser on the Statistics tab 5 5 1 Creating scenes Scenes can be created directly in the timeline using the timeline marker to select the period of interest or generated from existing segments Creating scenes from segments is useful when using events to set the start and end points of the section of the recording covered by the scene
38. and color of the dots the background color and the type of calibration stimuli and you can also perform the calibration manually 48 gi tobii To access the calibration settings 1 Click the Setup icon in the Design and Record tab 2 Select Settings 3 Inthe Global Settings dialog box click the Calibration tab 4 Now select a calibration type You can choose between Regular Manual or Infant calibration 4 3 1 1 Regular calibration Regular calibration is the default calibration in Tobii Studio Other than a few specific situations Regular calibration should be used as the standard type of calibration procedure The default settings for Regular calibration are set to five calibration points the color of the points is red the background is gray the speed is set to medium and the calibration is set to use the full screen Presentation of the dots is sequential and fully automatic To change the Regular calibration settings Click the Foreground Color drop down list and select the color for the points Set the calibration speed by selecting one of the five preset speeds in the Calibration Speed list Set Number of calibration points to 2 5 and 9 points Click the Background Color list and select the color of the calibration background screen Click Configure to adjust the area of the screen that will be used when performing calibrations This may provide a more accurate calibration if you are planning to use a small area
39. and or other countries User Manual Tobii Studio 2 X 9 4 3 Fixations Before count This metric measures the number of times the participant fixates on the media before fixating on an AOI or AOI group for the first time The fixation count starts when the media containing the AOI is first displayed and it stops when the participant fixates on the AOI When using AOI groups the fixation count stops when the participant fixates on any of the AOls belonging to the group If during the recording the same media is displayed several times with other media in between only the fixations on the media containing the AOI are counted fixations on the other media are excluded from the calculations If at the end of the recording the participant has not fixated on the AOI the Fixation Before value will not be computed and that recording will thus not be included in the descriptive statistics calculations e g when computing N Note When browsing a website or PDF document each visited web URL and PDF page will become a unique media element If the Web Groups tool is used to group two or more URLs the group and not the URL will become a unique media element Fixation Before Measured in counts ye pan j b 3 A 4 are i s 5 Fa 2 L e i LAOA d Fixations on media size indicates duration 1 000000 X lt a j A e f a j j n _ pie Be 4 pe i mt Media 1 view time Media 2 view
40. anywhere outside the list box to close it To include participant variables 1 Select the Participant Variables check box This adds the participant variables to the table 2 To select to display the participant variables as numbers instead of text select the Values as Numbers check box When the option Values as Numbers is selected for the participant variables a table containing the numerical translation between the values and the numbers will be displayed above the table containing the data 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 123 and or other countries User Manual Tobii Studio 2 X To change the cell format Click the Cell format button The Cell Format dialog box is displayed Set the number of decimals to be displayed by typing a number in the Number of Decimals field Set the decimal separator type the appropriate character in the Decimal Point field Set what to display if no value is available by typing the appropriate character in the No value field 5 To specify how percentage values should be displayed click the Percentage drop down list button The available options in the drop down list are Percentages and Decimals Click Done when finished ee 9 3 1 6 Chart options Displays the AOI analyses in a chart Charts can be easily created and exported as image files or copied
41. box and then selecting your audio source click the Audio Source drop down box and select the appropriate microphone 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 59 and or other countries User Manual Tobii Studio 2 X 3 Click OK to accept the changes or Cancel to close the window and disregard the changes 4 On the Replay tab select the recording in the Recordings list that you wish to show the subject during the RTA 5 Click the RTA icon on the Replay header 6 In the Start Retrospective Think Aloud Recording dialog box enter a name for the recording in the Recording Name field If you do not enter a name for the recording Tobii Studio will name it automatically by using the name of the recording you have selected in step 4 and adding RTA as a suffix Tobii Demo Pro File View Tools ForSight Help Design and Record Visualization Web usability Generate Export RTA Start Retrospective Think Aloud Recording Recording Name Rec 1 RTA Recordings Keyboard shortcuts Esc or F10 Stop recording Dm ee BN aN d Type Time instructionS 00 00 00 0 Task 1 A tart Boaco Book Task 1 Please go to the page where you capB a holiday start KeyPress 90 00 06 64 jc pace CLICK to open the web page InstructionE 00 00 03 038 Task T nd 5 ScreenRec ie 08 36 Star
42. click Create The description is optional To change between existing tests 1 Click the Test button to see the Tests in the current project available under all tabs except Statistics 2 Click the test you want to work with To copy media elements between tests but within the same project 1 Under the Design and Record tab view the test you want to copy the media element from 2 Right click the media element you can have multiple elements selected before right clicking and select Copy on the context menu 3 Select the test where you want to paste the media element Right click the media element on the timeline that is to the left of where you want to paste the object and select Paste on the context menu To delete an existing test 1 Open the test you want to delete 2 Either click the Test drop down menu or go to File on the menu bar and click Delete Test 3 Click Yes in the confirmation dialog box to confirm the deletion 4 2 Managing participants and independent variables Each Tobii Studio recording is associated with a participant and his her respective calibration data Participant data can be created and managed before or after the recording has been performed This data consists of a name which is used to identify the participant and user generated independent variables such as gender and age These variables can be used to create participant groups and filter the eye tracking data by these groups when producing v
43. codes are based on whether the system is able to correctly identify both eyes It is recommended that the validity codes always be used for data filtering to remove data points that are obviously incorrect Left eye Right eye Eyes found System left and right eye identification validity validity Estimated as probable Uncertain Validity codes should be used for data filtering to remove data points which are obviously incorrect If you export the raw data file we recommend removing all data points with a validity code of 2 or higher 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 75 and or other countries User Manual Tobii Studio 2 X 6 Defining fixations During a recording Tobii T X Series Eye Trackers collect raw eye movement data points every 16 7 or 8 3 ms depending on whether the sampling data rate is 60Hz or 120Hz respectively Each data point will be identified with a timestamp and X Y coordinates and sent to Tobii Studio In order to visualize the data these coordinates will then be processed further into fixations and overlaid on a video recording of the stimuli used in the test or on a static image or used to calculate eye tracking metrics see the Tobii whitepaper entitled Tobi Eye Tracking An introduction to eye tracking and Tobi Eye Trackers to learn more about eye movements and fixations
44. downloading the installation file for the new version of Tobii Studio 6 When the download is complete browse to the folder where the installation file was downloaded and click the installation file Tobii Studio Software Update License key Available updates to download Documentation Install file TobiiStudie 2 1 10 Beta release File Installation instructions Click on the Dovmload link above Save the file Close dorm Tobii Studia Install the newly dovmloaded version 7 Follow the on screen prompts and instructions to complete the installation Tobii Studio upgrades improve program performance and the feature set They also fix bugs resolve connection and timing issues and improve compatibility with new operating systems Check for updates on a regular basis tobii 2 Managing Tobii Studio Projects Tobii Studio organizes and stores information on three hierarchical levels Projects Tests and Recordings The top most level is the Tobii Studio Project This level contains participant data and one or more tests Each test created within a project contains one or more media elements the stimuli which are organized into a single linear timeline and recordings Charts Recording 1 Recording 2 Recording 3 Visualization The test also contains information on how the different media are presented to the test participant such as the order and the duration of each media element Recordings i
45. edit an existing participant group 1 Click the Filter by drop down list button This opens the Participant Groups list 2 Click the Edit button to the right of the group name in the Participant Groups list This opens the Edit Group dialog box 3 Change the group name in the Participant Group Name field 4 Click an independent variable in the Variables list and select the values you wish to include or exclude in the group definition by selecting the check boxes in the Values list 5 Repeat step 4 for other variables you wish to change 6 Click OK to accept or Cancel to dismiss the changes To delete an existing participant group 1 Click the Delete button tothe right of the group name in the Participant Groups list 2 Confirm the deletion by clicking Yes in the Delete Filter dialog box If you wish to cancel the deletion click No 7 3 Selecting data from a time interval You can choose to restrict the data used to create the visualization according to a time interval For example you can create a heat map showing the fixations made during the first 2 seconds of the stimulus display The interval can be determined in two different ways The first way is by dragging the markers on 86 tobii the visualization timeline and the second is by setting the Start and Length time values in the respective fields To set the time interval using the timeline markers 1 Drag the left marker to set the start of the data inte
46. en cn a ee ee ea ETEEN 137 9 4 14 Visit Count zero COUN ceeeceseccesescssessscesseesssececsecacsesacsesecacsecacsecaesesatsesavaesevaneesansesansesasaneesaneneaners 138 9 4 15 Percentage Fixated U0 peter eee ee ere carne tennis ene me eee ee ee eee ee 138 9 4 16 Percentage Cgc ace ncecnce ose cea cescetsnds pecteatan toa vaceesciucanassessndaeiaataptetacaeaeuentencestscpckechenntuanecss 139 9 4 17 Mouse Click Count COUN ccseessseesessessessesessesesseseesesseseesassecesaseesassesesasseseesaseesaneaseesansnsaes 140 9 4 18 Mouse Click Count Zero COUN cesssessssesscesescessssssescsceccecsceecausecaesesacsecevansecacsesaesaeausesanensatneanes 142 9 4 19 Time to First Mouse Click SECONAS cssscsscecessesssssssssssecseseeseeseesaeseesassessesaeseeseesassaseatensensaneanss 142 9 4 20 _ Time to First Mouse Click Across Media seconds sessssssesessesesesessesesesseeseessteseetereeneeeas 143 9 4 21 Time from First Fixation to Next Mouse Click secondS sssscesceeessessessersessssssseteeeeesensanes 144 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 3 and or other countries User Manual Tobii Studio 2 X 9 4 29 Time from First Fixation to Next Mouse Click Across media seconds 146 9 5 Copying tables and charts to the clipboard 0 eee eceeeeeteeeeteeeeeeeeeeeeeeeeeeeeaenese
47. field or by clicking the Browse button browsing to the folder location 3 Select the Project Test and Recording check boxes if you wish to create subfolders for each of the three data levels Folder settings a Output folder C Users rms Desktop Browse Create sub folders E Project F Test Recording Help Export scope Curent recording 0 All recordings in test O Segments in curent recording 6 Al segments from all recordings in test Preset Configurations Advanced 70 Text export configuration Description All data Data for all gaze points E Event data Event data EI AO data Fixations on 4Ol s one ADI on each row E Fixation data Fixations compatible with Clearview fixation data export E Combined data Compatible with Clearview combined export E Pupil size Delete contiguration 4 Inthe Export scope section specify the scope by choosing between Current recording All the recordings in a test Segments in current recording or All segments from all recordings in test 5 On the Preset Configurations tab select the default configurations for your text exports or click the Advanced tab to configure your text export 6 Click Export to complete the process and save the files to your hard disk tobii Default configurations All data Exports all the data available in the Text Export options Event data Exports time stamped user events such as key presses mouse clicks recording events s
48. filter recordings see sections 7 2 1 and 9 2 1 1 of this manual pages 85 86 and 115 117 respectively 4 3 Calibrating and recording participants Recordings are initiated by clicking the Start Recording button located at the bottom of the window on the Design and Record tab In order to start a recording you need to create a new or select an existing participant and perform a calibration The calibration process ensures that the eye tracker learns the characteristics of the subject s eyes and accurately calculates the direction of his her gaze on the surface of the screen or object Before starting the recording session make sure that Tobii Studio is connected to the eye tracker and that the study design and settings are set correctly To check the connection status between the eye tracker and Tobii Studio 1 Below the Start Recording button there is an indicator that shows the serial number ID of the eye tracker and whether it is connected or not Connection OK No Connection Click this serial number ID EP Eyetracker TT120 204 83500407 Connection OK 2 Inthe Eyetracker Selector dialog box click the eye tracker row to select it 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 47 and or other countries User Manual Tobii Studio 2 X 3 Click Test selected eye tracker to complete the connection
49. from www tobii com Products amp Services section Information on different configurations for the Tobii TX Series Eye Tracker setups can be found in the eye tracker user manual that is shipped with the eye tracker If the manual has been misplaced or lost you can download a PDF version of the manual from the Support amp Download section at www tobii com Detailed documentation on Tobii Studio timing of stimulus display as well as Tobii Eye Trackers sample timing information is available upon request Contact Tobii Support or your sales representative in your area to obtain a copy of the Timing Guide for Tobii Eye Trackers and the Eye Tracking Software whitepaper E Prime Extensions for Tobii combine E Prime Professional Stimulus Presentation Software with the ease of use of Tobii Eye Trackers and Tobii Studio s visualizations and AOI analysis The E Prime Extensions for Tobii includes the script necessary to integrate E Prime with Tobii Eye Tracking Technology E Prime Extensions for Tobi documentation can be downloaded from www tobii com Support amp Download section and http www pstnet com eprime cfm Support section To download the documents you need to have valid licenses for E Prime E Prime Extensions for Tobii and Tobii Studio Contact Tobii Support and register at the PST Web Support Site Training Tobii Technology provides Tobii Studio online and onsite training Our training solutions are tailored to fi
50. hi d E3 Juice 0t jpg a ee ee e a ee T Extra gentle for the most sensitive skin a L Juice 02 jpg m Newspaper Black and White jpg Media List Newspaper Color jpg Travel 01 jpg m Travel 02 jpa Welcome Sni 3 Web Groups Filter by No Group Selected Name Color Q Res Rec7 V Rec6 Rec 5 V Rec2 Q Rec1 O Rec4 Rec3 m Recordings Check Uncheck Name Area baby 19 45 headline 10 03 text body 13 96 dippers E 7 24 brand 362 quality statement M 4 52 Areas of Interest a a h i Ellipse Rectangle Polygon peste Ect Bring to Front Bring Forward Send Backwards Send to Back AOI Groups Delete AOI DEL Rename F2 Expand AOI to Edges Copy AOI Ctrl C Paste AO Ctrl V Zoom In Zoom Out Fit to Screen Export If you are not satisfied with the baby leakage protection you will eem Read more about our leakfree guarantee at www baby com Drawing Style ultra sensitive skin add the chemicals and moisture nd stools and you have diaper rash er s unique high absorbency natural blend cotton rovides cotton ga thick gel free protection by s sensitive skirjhe chlorine free materials and polymers is non toxic and non irritating Clinically pediatrician recommended for babies with allergies 7 Show Name Labels Transparent 2010 Tobii Technolog
51. if you pressed the wrong key The comment will be displayed in the Text column of the Events list 6 Double click the respective color to open a color palette and choose the color of the bookmark that is placed on the timeline 7 Repeat steps 3 6 until you have created all your events Then click OK 8 Click the Replay tab select the recording you would like to playback and start logging the events You can also use manually logged Events to create segments to help select portions of the recordings that can be used to create movies or scenes In order to accomplish this you need to create an event that bookmarks the start of the segment e g Smiling Start and another to bookmark the end of the segment e g Smiling Stop You can then go through your recordings and bookmark the periods where the participants smiled and use the automatic segmentation tool to create segments using those two bookmarks To edit a manually logged event 1 Right click the event in the Events list 2 Select Edit Log entry 3 Inthe Edit Log Message dialog box you can select a new event type from the list or type information in the field 4 Click OK to accept the changes To delete a manually logged event 1 Right click the event in the Events list 2 Select Delete Log entry 3 Click Yes to confirm the deletion 5 3 2 Filtering events The Events list can be filtered to show only specific events in the list and in the timeline This feature
52. is the case reposition the test participant in front of the eye tracker and check for any factors that could be interfering with pupil detection e g an infrared light source that is directed at the eye tracker sensor or the participant s eyes dirty or scratched glasses or droopy eyelids Click Recalibrate to recalibrate the subject Optional When you perform the test on a screen you can also assess the quality of your calibration by clicking the Verify button in the Accept Calibration dialog box The participants gaze point is displayed as a small pink dot in real time on the screen together with an image containing several larger colored dots Instruct the participant to look at the center of the colored dots If the calibration was accurate the gaze point should overlap the colored dots The distribution of the colored dots also allows you to assess calibration accuracy in different areas of the screen Click ESC to exit 9 If the calibration seems to show accurate results click the Accept button to open the Start Recording dialog box Calibration haa Accept Calibration Left Eye Right Eye a Y 0 Points Marked for Recalibration _ Very Recalibrate Cancel 54 tobii 10 In the Start Recording dialog box enter a name for the recording make sure to use informative names and look at the track status box to confirm once more that the participant is correctly positioned in front of the eye tracker 11 Click Start
53. name of the data column in the export table e Select Write filter header to display the name of the filter used to calculate the fixation data e Select Export gaze data to export the data related to the gaze point calculations e g gaze X and Y coordinates distance pupil size e Select Only fixations to limit the gaze data export to display only fixation information for example the file does not include the raw gaze X and Y coordinates from the eye tracker only the mapped coordinates e Also select Print AOls on separate rows to display each AOI on a separate row e Select Export events to include event data such as key presses and mouse clicks e Select Exclude scenes to remove the scenes from the text export data This is often an option you want to leave selected If scenes are included fixations will be mapped to scenes instead of the underlying media 3 Select the data columns you want to include in your export by simply clicking the desired column in the Available columns list and then clicking the gt button to move the column to the Selected columns list Use the Clear All and Add All to add or remove all the available columns to the Selected columns list Change the order of the columns in the export file by selecting a column from the Selected columns list and clicking the desired direction arrow located to the right of the list 4 If you plan to export more recordings using these Advanced settings type a name in the Save
54. on media size indicates duration Qocoopo C 0 LS Time from First Fixation to Next Mouse Click Across Media on AO B in Media 1 9 4 22 2 Brief description The time from the first fixation on an AOI until the test participant left clicks with the mouse on the AOI or AOI group for the first time seconds 9 5 Copying tables and charts to the clipboard To use this function you first need to create a chart Use the copy function to quickly copy a table or chart into a document To copy a table or chart 1 Click the Copy button to show the Copy menu 2 Select Copy Table or Copy Chart The table chart is copied to the clipboard 3 Use the paste function in your document editor or use the paste keyboard shortcut English keyboards CTRL V to paste the image BMP file or table TXT file content into your document 9 6 Table and chart export To use this function you first need to create a table Use the export function to save the table or chart into a file that you can later import or add to a document 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 147 and or other countries User Manual Tobii Studio 2 X To export a table 1 Click the Export button to show the Export menu 2 Select Export Table The Save As dialog box opens 3 Type the file name select the location where yo
55. p u z p 1 SN O 10 N I0 1 11 0 J N 9 41414qd A Oba ie N 10 1 0 1 1 JOVdS MOUddV NMOG MOddV dN MOudadV 145351 MOddV LHDOIY Lbs Olds E TTILE s y ynoyoys pseoghey opns qoL tobii www tobii com Tobii Support contact SWEDEN GLOBAL 46 8 522 950 10 Phone support tobii com www tobii com Support hours 9 am 5 pm Central European Time GMT 1 Tobii Sales contact HEADQUARTERS Tobii Technology AB Karlsrovagen 2D Box 743 S 182 17 Danderyd Sweden 46 8 663 69 90 Phone 46 8 30 14 00 Fax sales tobii com GERMANY 49 69 2475 034 27 Phone support tobii com www tobii com Support hours 9 am 5 pm Central European Time GMT 1 CENTRAL EUROPE Tobii Technology GmbH Niedenau 45 D 60325 Frankfurt am Main Germany 49 69 24 75 03 40 Phone 49 69 24 75 03 429 Fax sales de tobii com NORTH AMERICA 1 703 738 1320 Phone support us tobii com www tobii com Support hours 8 am 5 pm US Eastern Standard Time GMT 6 NORTH AMERICA Tobii Technology Inc 510 N Washington Street Suite 200 Falls Church VA 22046 USA 1 703 738 1300 Phone 1 888 898 6244 Phone 1 703 738 1313 Fax sales us tobli com JAPAN 81 3 5793 3316 Phone support jo tobii com www tobii co jp Support hours 9 am 5 30 pm CSEE JAPAN Tobii Technology Ltd 3 4 13 Takanawa Minato ku Tokyo 108 0074 Japan 81 3 5793 3316 Phone 81 3 5793 3317 Fax sales jo tobil com
56. power failures power spikes system crashes and other unexpected external events It is thus recommended that you create a backup of your data regularly In Tobii Studio there are several ways you can backup your project database for example you can export the project or you can copy and paste the project folder from its original location to another disk However the easiest way is to use the Tobii Studio s Backup Database feature To back up a Tobii Studio project 1 Start Tobii Studio and open the project you wish to back up 2 On the File menu select Backup Database 3 To set the location of the backup type the target path or click the Browse dialog box button and find and select the desired location Database Backup This will make a copy of your database including all stimuli and recorded media Target path V Create sub folder using today s date Required disk space 64 MB Start Backup Cancel 4 Click the Create sub folder using today s date radio button to copy the project into a folder named with the date you are performing the backup This helps to keep track of when the last backup was made 5 Click Start Backup and your project is then copied to the chosen location To access and open your project backup in Tobii Studio Start Tobii Studio to open the Tobii Studio Project Library Click the button Link Project to Library and locate the backup file Click the file to select it and the
57. size measurements are calculated to be as close to real values as possible However individual differences in the eyes of subjects and the strength of glasses contact lenses will cause errors in these values However the measurements still reflect changes in head position and pupil size accurately e ValidityRight Validity of the gaze data The validity is O if the eye is found and the tracking quality good If the eye cannot be found by the eye tracker the validity code will be 4 The value is for the right eye For details see the Validity codes section further down Additional data processed by Tobii Studio e DateTimeStamp Timestamp recalculated using the computer date time shown in hours minutes seconds and milliseconds hh mm ss ms e DateTimeStampStartOffset Timestamp converted into hh mm ss format The start time for the recording is also shown in the Replay and Visualization views in Tobii Studio if the option Show Date is selected in the Recordings field e Number Timestamp number order 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 73 and or other countries User Manual Tobii Studio 2 X 74 FixationIndex Indexes for the fixation points values correspond to the order of the fixation GazePointX Gaze PointX can be the horizontal screen position for either eye or the average for both eyes
58. test participants changes over time To create an animated visualization 1 Click the Export button on the Visualization header and select Animated Visualization The Movie Settings dialog box opens Movie Settings AN encoder Frames per Second 10 Video codec Microsoft Video 1 Gaze Data Settings Accumulate gaze data over frames Sliding window interval length 102 Select the frame rate of the video file by clicking in the Frames per Second second field and typing a value alternatively you can use the arrows in the field to change the value Choose the video codec to use to compress the video file by clicking the Video codec drop down list and selecting the codec Click Edit if you want to add a new codec to the list Select how the gaze data will be plotted over time e Select Accumulate gaze data over frames to progressively add all the fixation data to the image tobii For example the red rectangle in the image below represents the gaze data interval that is displayed on the heat map during the first second of playback using the Accumulate gaze data option the m ensitive skin St ith ultra sensitive skin add the chemicals and moisture of and stools and you have diaper rash Baby diaper s unique high absorbency natural blend cotton ing provides cotton soft extra thick gel free protection baby s sensitive skin The chlorine free materials and nt polymers is non toxic and non irritating
59. the AOI metric summary columns the N value represents the number of recordings x the total number of AOls i e all AOls included in all media elements Time to First Mouse Click Across Media Measured in seconds R D Mouse click on media 9 4 20 2 Brief description The time from the start of the media display until the test participant left clicks with the mouse on the AOI or AOI group for the first time seconds 9 4 21 Time from First Fixation to Next Mouse Click seconds This metric measure how long it takes before a participant left clicks with the mouse on an AOI or AOI group once he she has fixated on it The time measurement starts when the participant fixates on the AOI for the first time and stops when the participant clicks on the same AOI When using AOI groups the time measurement starts and stops when the participant fixates and clicks on any of the AOls belonging to the group 144 tobii If during the recording the participant views a different media between the first fixation and the mouse click the time spent viewing the other media element is excluded from the calculations If at the end of the recording the participant has not fixated and clicked on the AOI the Time from First Fixation to First Mouse Click value will not be computed and that recording will thus not be included in the descriptive statistics calculations e g when computing N Note When browsing a website or PDF document each visi
60. the N value will always be equal to 1 If participants are selected as table rows the N value will be equal to the number of recordings that participant has made with the same media element If participant groups are selected as rows then the N value will be equal to the number of recordings included in the group Summary columns In the AOI media summary columns the N value represents the number of recordings x the number of AOls included in a single media element In the AOI group summary columns the N value represents the number of recordings and follows the rules described in the previous paragraph row settings In the AOI metric summary columns the N value represents the number of recordings x the total number of AOls i e all AOls included in all media elements 9 4 11 2 Brief description Duration of all visits within an AOI or an AOI group seconds 136 tobii 9 4 12 Total Visit Duration zeros seconds This metric is calculated in the same way as Total Visit Duration with the exception that if at the end of the recording the participant has not fixated on the AOI the Total Visit Duration value will be registered as zero and the recording will be included in the descriptive statistics calculations e g when computing N and means 9 4 12 1 Brief description Duration of all visits within an AOI or an AOI group seconds 9 4 13 Visit Count count Formerly Observation Count in older versions of Tobii Studi
61. the United States 51 and or other countries User Manual Tobii Studio 2 X To show the calibration animation selected in the Global Settings dialog box press the RIGHT ARROW key When the subject is watching the animation press the RIGHT ARROW key again to start collecting calibration data It is assumed that the subject will focus on the center of the calibration animation When enough data points are collected the calibration will move on to the next calibration point The operator can again press the RIGHT ARROW key to start collecting data This is repeated until all calibration points are completed The following keys are used to control the Infant calibration procedure e RIGHT ARROW Displays the calibration AVI at the next calibration point If the calibration AVI is already visible a calibration is made at that point before proceeding to the next e LEFT ARROW Pause Hides the calibration AVI or the full screen attention grabbing AVI e UPARROW Displays the attention grabbing AVI 4 3 2 Making recordings Place the participant in front of the eye tracker and make sure that he or she is sitting comfortably at an approximate distance of 64 cm The distance depends on the hardware used 64 cm is valid for the Tobi TX Series Eye Trackers whereas for the Tobii 50 series the distance is 60 cm see the TX Series Eye Tracker manuals for more information To start a Tobii Studio recording 1 Click the Start Recording button loc
62. the test subject such as slightly behind and to the side of the subject or immediately over the subject s head 4 1 2 8 Questionnaire The Questionnaire media element can be used to present multiple choice questions to which the participant may only select one answer to each question The answers to the questionnaire can later be used as independent variables which can be used to filter the eye tracking data for visualizations and descriptive statistics reports To name the Questionnaire element 1 The software uses Questionnaire Element as the default name You can change it by clicking in the Element Name field deleting the existing text and typing a new name Questionnaire element sel Ip E Enter one or more questions below Questions are an altemative way to set Independent i Variables for participants Flement name Questionnaire Hement Questions Add Question Question text Possible anwers Variable t ey In Excel enter a question in the first column the answers in the second o You copy and paste from Excel into the area above column as a comma separated list and a vanable name in the third column To create a Questionnaire element h Click the Add Question button to open the Question Setup dialog box 2 In the Question field type the question you want the participant to see 3 Add the multiple choice answer choices to the Answers section by selecting Create new or Use values
63. the type of fixation filter you change the way a single fixation is defined i e how many individual gaze points a fixation will be composed of and as a consequence both count and duration values change 9 4 1 Descriptive statistics Descriptive statistics are used to present the data values calculated by each eye tracking metric The meaning and value of the descriptive statistics vary with the column row and metric options Refer to the metrics descriptions in the following sections to interpret the descriptive statistics values Descriptive Definition Statistic number of recordings fixations visits or participants Describes the central tendency of a set of data values It is calculated by summing all the data values and dividing by N number of data values Tobii Studio calculates the arithmetic mean Lowest value in the data set The value that separates a data set in two halves The value is calculated by first arranging a finite list of data values from lowest to highest value and then determining which data value is located at the middle of the list the median value If the number of data values is even then there is no single middle data value The median is then defined by the average of the two data values Sum Stdev Standard deviation 9 4 2 Time to First Fixation seconds This metric measures how long it takes before a test participant fixates on an AOI or AOI group for the first ti
64. to the AOI name in the Areas of Interest list 2 Select AOI Groups in the menu and click the AOI group you want to remove the AOI from Tip If the Show Name Labels check box is selected the label will display the AOI name and the name of any AOI groups that it belongs to 112 tobii 9 Calculating eye tracking metrics and statistics The Tobii Studio Statistics tool is used to calculate and display eye and mouse tracking metrics descriptive statistics These metrics are calculated based on user defined Areas of Interest AOls and data selection time intervals The data that results from the analysis is displayed in the form of a table and or chart The Tobii Studio Statistics tool supports the creation of complex tables such as cross test tables composed of multiple media within a single project creation and export of multi metric tables and cross tabulation using participant independent variables or responses from questionnaires as filters to group participants The tool also supports the production of descriptive statistics from AOI groups Screnthe Propert File View Tools Forsight Help Design amd Record Replay Visualization Metnic Tine to First Fiabon ki Rowe Recardngs 7 Fiterby No Group Selected I all gt catcutate by Descriptive Statistics Participant Variables Participant Recordi Date s l FeO To get started seleci one or more meda from curent propect To open the Tobi
65. 4 52 i If you are not satisfied with the baby leakage protection you will back Read more about our leakfree guarantee at www baby com EN ERI ie i A S Elipse Rectangle Polygon T Areas of Interest To create a new AOI 1 Click a media in the media list Note The media has to be a static image If the media is a screen recording or a movie AVI you need to create scenes first before the AOI Tool can be used Read more on how to create scenes in section 5 5 of this manual pages 67 69 9 Click the AOI Tool button located on the Visualization header 3 Add a new AOI by clicking the desired shape tool Ellipse Rectangle or Polygon located towards the lower part of the Visualization pane in the Create section of the AOI menu 108 tobii 4 Draw the AOI on the image by clicking around the area where the AOI should appear Each click will define an anchoring point for the selected geometrical shape To quickly create an AOI that fills the entire screen click the Select cursor in the lower Tools menu and click a pre drawn AOI Right click the AOI and select Expand AOI to Edges from the context menu 5 Select the Fill check box to color the Areas of Interest and drag the Opacity slider to change the opacity of the color fill 6 Click the Border Style drop down list and select the appearance of the AOI line Change the line thickness by typing a value in the Bo
66. 4 6 2 Brief description Duration of all fixations within an AOI or within all AOls belonging to an AOI group seconds 9 4 7 Total Fixation Duration zeros seconds This metric is calculated in the same way as Total Fixation Duration with the exception that if at the end of the recording the participant has not fixated on the AOI the Total Fixation Duration will be registered as zero and the recording will be included in the descriptive statistics calculations e g when computing N and means 9 4 7 1 Brief description Duration of all fixations within an AOI or within all AOls belonging to an AOI group seconds 9 4 8 Fixation Count count This metric measures the number of times the participant fixates on an AOI or an AOI group If during the recording the participant leaves and returns to the same media element then the new fixations on the media will be included in the calculations of the metric If at the end of the recording the participant has not fixated on the AOI the Fixation Count value will not be computed and the recording will not be included in the descriptive statistics calculations e g when computing N Fixation Count Measured in counts Fixations on media size indicates duration Pe ect a aS EY LAA L A amp I WY ou a a 9 4 8 1 N value This statistic describes the N value used to calculate other descriptive statistics such as the mean and standard deviation In the current metric it represen
67. 5 larger Note All values in the X Series Configuration Tool must be measured and added correctly to ensure data accuracy see the Tobii X120 amp X60 Eye Tracker User Manual for more information To access the X Series Eye Trackers Configuration Tool in Tobii Studio 1 Click the Tools menu and select Settings 2 Inthe Global Settings dialog box select the Eye Tracker tab and click the X Series Config Tool button To compensate for the scene camera perspective 1 Use the Preview image to adjust the camera s position so that it shows an image of the surface you want to eye track and then secure the camera to avoid any accidental shift in position 2 Place the calibration grid on the object s surface d calibration plane we camera perspecti 3 In the Perspective Calibration section click New A snapshot of the camera video feed is shown in the Calibration Image box along with a polygon with five calibration points 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 35 and or other countries User Manual Tobii Studio 2 X This element records everthing that is received from an extemal video source until it is manually stopped t allows perspective mapping of gaze data Flement Name Scene Camera Element Camera Capture Perspective Calibration Video Source Logitech QuickCam Chat Camera S
68. 5237397 1253x1208 Yes Spotify Download Spotify f http www spotify com en download windows 625237397 1253x1208 Yes Spoti Spoti https www spotify com en login 588754869 1253x902 Spoti https www spotify com en products premium order account 614580847 1253x1375 Spoti https www spotify com en products premium order account 1345937647 1253x1375 Yes Downloa https www spotify com en products premiumorder account 1721648799 1253x1375 Dowr Premium Spotify 5 Dowr Premium Spotify http www spotify com en products premium 1009428553 1253x902 Yes F You are buying premiu You are buying pre https www spotify com en products premium order payment 2014076302 12532924 You are buying pre https wuww spotify com en products premium order payment 2067932442 1253 924 You are buying pre https www spotify com en products premium order account 614580847 1253 1375 Products overview 5 Premium Products overview http www spotify com en products overview 1314235604 1253x902 Prem Products overview http www spotify com en products overview 715645332 1253x902 Yes You are E New group Yous 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 83 and or other countries User Manual Tobii Studio 2 X 2 Rename the new group by double clicking it
69. 8 ACM New York NY USA 7 7 Exporting gaze plots heat maps and clusters Visualizations can be exported as image files or as animated movies that show where people have fixated over time To export a visualization image eS click Save 7 7 1 Batch export Click the Export button on the Visualization header and select Export Current Image In the Save Image dialog box select the folder and type the file name Select the type of image file JPEG BMP or PNG and then click Save In the Information Legend Settings dialog box choose the settings for the image s legend and This feature can be used to batch export visualization image files with multiple participant filters from only the current media from all the media within a single Tobii Studio Test or all the media from all the tests included in the current project To batch export visualizations 1 Click the Export button on the Visualization header and select Batch Export File settings Output folder C Users wms Documents Export scope C Only export current media Export from all medias in current test Export from all medias in all tests in current project Participant Filters Filtername V All V Young men Female Time settings Use current time Use max time interval of Media Information legend V Show legend Legend position V Media name Choose Font V Participant Filter Background color i m Time Opacity
70. AOI group summary columns the N value represents the number of recordings and follows the rules described in the previous paragraph row settings In the AOI metric summary columns the N value represents the number of recordings x the total number of AOls i e all AOls included in all media elements 9 4 21 2 Brief description The time from the first fixation on an AOI until the test participant left clicks with the mouse on the AOI or AOI group for the first time seconds 9 4 22 Time from First Fixation to Next Mouse Click Across media seconds This metric measure how long it takes for a participant to left click with the mouse an AOI or AOI group for the first time after he she has fixated on that AOI The time measurement starts when the participant fixates on the AOI for the first time and it stops when the participant clicks on the same AOI When using AOI groups the time measurement starts and stops when the participant fixates and clicks on any of the AOls belonging to the group lf during the recording the participant views a different media between the first fixation and the mouse click the time spent viewing the other media element will not be excluded from the calculations lf at the end of the recording the participant has not fixated and clicked on the AOI the Time from First Fixation to First Mouse Click value will not be computed and that recording will thus not be included in the descriptive statistics calculations e
71. AOls are counted twice in the calculations i e once per AOI To copy paste and delete an AOI 1 After selecting the AOI right click it and in the context menu select Copy AOI or use the keyboard shortcut CTRL C 2 Right click the media and in the context menu select Paste AOI or use the keyboard shortcut CTRL V 3 To delete the AOI select the AOI and then right click it In the context menu select Delete AOI or click the AOI and use the keyboard shortcut DELETE AOI data can be exported and used for further analysis in external software The AOI Export contains the screen coordinates of the AOls For rectangles and polygons the coordinates are the corners For ellipses the coordinate points are along the outer line of the ellipse To export the AOI coordinates 1 Right click the image and select Export 2 Inthe Save As dialog box select the folder and type the file name A TXT file is created that can be opened in a text editor or a spread sheet application e g Excel To export the AOI image 1 Click the Export button on the Visualization header and select Export Current Image 2 Inthe Save Image dialog box select the folder and type the file name 3 Select the type of image file JPEG BMP or PNG Now click Save To learn how to batch export AOI images see section 7 7 1 of this manual pages 101 102 8 3 Creating AOI groups AOI groups are used to group different AOls within a single media as wel
72. Auto generating segments Before generating the segments you first need to identify or create the events that you will use to determine the start and end points See the previous section to learn how to create events To automatically generate segments 1 Click the Generate icon on the Replay tab and select Segments 2 Inthe Auto Generate Segments dialog box start by typing a name that will be used to identify the segment in the Segment name prefix field Segments name pretie Segment Start Stop points Help To set time before an event select a negative time offset as the start point Generate segments for Curent recording Segment start point Al recordings in curert test Eventtyps soenetstat All recordings in all tests Time offset 00 00 00 000 Segment stop point Event type scene stop k Time offset 00 00 00 000 r T 3 Select to generate the segments for the Current recording for All the recordings in the current test or All the recordings in the project 4 Select the segment start and stop points from the event type lists 5 You can also choose to add a time offset to the start or end of the segment The offset can be used for example to adjust the size of the segment if you see that you are missing a small portion of the video in some of the recordings 6 Click OK to create the segments 7 To view the segments select the desired recording and make sure the Segments pane is visible
73. CHINA Tobii Electronics Technol ogy Suzhou Co Ltd No 678 Fengting Avenue Land Industrial Park Weiting Suzhou China Post code 215122 86 13585980539 Phone sales cn tobii com Tobii Studio 2 X User Manual Content subject to change without notice Please check Tobii web site www tobii com for updated versions of this manual Manual Version 1 0 2010 Tobii Technology Illustrations and specifications do not necessarily apply to products and services offered in each local market Technical specifications are subject to change without prior notice All other trademarks are the property of their respective owners
74. Capture tab select the Enable remote viewing check box If a user camera and or sound is to be used this has to be enabled as well by selecting the Broadcast Sound and Camera image check boxes 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States and or other countries 151 User Manual Tobii Studio 2 X Note If Tobii Studio Logger is to be used for remote viewing on more than one computer the Multicast option must be selected If only one remote computer is used for logging or remote viewing do not select this option as it might affect the remote viewing performance 4 Click OK to accept the changes 5 Open the Windows Start menu select All Programs gt Tobii gt Studio then click Studio Logger to open the Studio Logger application 6 On the Studio Logger header open the Connection drop down menu located to the left of the Test menu and then select New Connection to enter a new IP address 7 Inthe Connect to Server dialog box type the IP address of the Tobii Studio computer and click Connect The connection status is displayed in the lower part of the Remote Desktop pane and below the Start Recording button File Help A lt vr vr vr 10 46 1103 Readingan Setup Category Show Track Status Remote Desktop 10 46 1 103 scene start Hide Main Application scene stop Gaze overlay set
75. Click Count for AOI B in Media 1 3 9 4 17 2 Brief description Number of times the participant left clicks with the mouse on an AOI or an AOI group count 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 141 and or other countries User Manual Tobii Studio 2 X 9 4 18 Mouse Click Count zero count This metric is calculated in the same way as Mouse Click Count with the exception that if at the end of the recording the participant has not clicked on the AOI the Mouse Click Count value will be registered as zero and the recording will be included in the descriptive statistics calculations e g when computing N and means 9 4 18 1 Brief description Number of times the participant left clicks with the mouse on an AOI or an AOI group count 9 4 19 Time to First Mouse Click seconds This metric measures how long it takes before a test participant left clicks with the mouse on an AOI or AOI group for the first time The time measurement starts when the media containing the AOI is first displayed and it stops when the participant clicks on the same AOI When using AOI groups the time measurement stops when the participant clicks on any of the AOls belonging to the group If during the recording the same media is displayed several times with other media in between the reported time will be the sum of the ea
76. D The Group Criteria options are located in the top section of the Web Groups Tool dialog box Below these options you will find two lists Each list displays all the web frames visited during the web recordings Group Ci t fn Ben baa pou can Hid ham mab papii ore popad beset im the WAL Corten if vinai paian vi Tia tee Shee belmar irh of Shae predated m mode orice thes grouping Founs by seding iha maraa UAL ad Sipe amp Mare agten Dra ira haa bes idee bets bo make maraa serie ad Haig a prp Fimis iki Casan ID Sigs Gria bkg a Content it Sine Gimp lnag hitpeames ipah niir padue pii edanean ASIAT ies Yau hiig eaaa ipay garian piae prier aa HSS 12S ae Piipa iaa aih aa a pisdi i pae ad eiri MSF 1SeA TTS Ais end piy Doren padi peed LST 1E itil ean ipali ai irlar Jaaman pper Piga eevee ipie an D EA Piia a i erra ri pith parara abe ie 177e m15 hiipi ewe opty corer pr perce a TT 175 Dania Siiip i Deri iy for Wiee Dimna Spoki l hiij Bena ipii i rinl eareicenny E PTa ne cy iS Yei iiad 5 pacity lhe Vaikmaa Hic ewe tpt coer erudite paradocs TT Wet Ye Diced Soniy hitge fiver iy doen prided eerie ree ice 208 Yii Darii 5 polity ba irda hiig veren opty oon orai eda ENIN Udell ea Fira Spy i Pip Sentiy Fret gdy hips ver telly Gamers piaui pee ihe te oi Pac 1 Yii a a hiipui veaa ipai bi ery piai prar ih WP Ves Preducte peme Products iiae Spali Piebe a hiipi pi conv iraa err Tse ied Vet Pesducth pepi iey Hila eena
77. Log Categories S pn O A world of music instant simple and free E Gates e ra 2 2 rI o SS Day Mss Premium Buy now gt User Camera live Viewer Start Recording d Log History User Camera Status Ready WebTest 16 Recordings The Studio Logger window is divided into three main areas e Studio Logger header Contains the connection menu the Test menu and the Setup menu e Side pane This is where you can select from and view a list of events Log Categories list view the log history list Log History and view the video from the user camera User Camera The Side pane can be hidden by clicking the hide pane button located below the User Camera image box e Remote Desktop pane This is where you can view the image from the Tobii Studio computer start and stop the live viewer stream Live Viewer button and the recording Start Recording button and control the view time of the different media Next Stop button 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 149 and or other countries User Manual Tobii Studio 2 X The Studio Logger window can be customized by clicking the Log History and User Camera buttons below the User Camera image box to toggle between hiding and displaying the Log History list and the User Camera image b
78. Manual TobiiStud tobii Tobii Technology Tobit Studio 2 X Software Release 2 2 This document contains information proprietary to Tobii Technology AB The contents are confidential and any disclosure to persons other than officers employees agents or subcontractors of the owner or licensee of this document without the prior written consent of Tobii Technology AB is strictly prohibited No part of this publication may be reproduced stored in retrieval system or transmitted in any form or by any means electronic or mechanical including photocopying and recording without the prior consent of the copyright holder Manual release 1 0 September 2010 Tobii Technology AB reserves the right to change the content of this manual without prior notice Changes due to typographical errors innacuracies or modifications in programs and or equipment might be implemented at any time Please check the Tobii web site www tobii com for updated versions of this document All rights reserved Tobii Technology AB tobii www tobii com Preface Tobii Studio 2 2 Tobii Studio offers a comprehensive platform for the recording and analysis of eye gaze data facilitating the interpretation of human behavior consumer responses and psychology Combining an easy preparation for testing procedures and advanced tools for visualization and analysis eye tracking data is easily processed for useful comparison interpret
79. Manual Tobii Studio 2 X 8 Delete the default name and type the new one This step is important for later identifying the scene in the media list of the Visualization tab and in the media browser on the Statistics tab Note When a scene is created the scene will be copied to the remaining test recordings without the recording coverage information If you wish to add the coverage information to that scene you need to either select the interval manually select the interval in the timeline then right click the selection select Add selection to scene and then select the scene you want to use or if you are creating scenes for a movie element open the Scene context menu and select Copy content to all Recordings You can also create an empty Scene by right clicking in the Scene pane and selecting Create new scene To create new scenes from segments 1 Select the recording to use for this task and make sure the Segments and Scenes panes are visible 2 Right click the Scenes tab and select Create new scene 00 00 49 607 i ra fad Teal JPG RJ Sides Te C ins P EP BrP BDrEDrlin_ 7 ES si fa aa iat 1 KUT J dl mal wale WLR Mel I H n pavanu fom E ong amomo o a209 ooonasooo ooo1oso0 000128000 semena Jef O O ooo Segment 1 fe gt Segments Drag segments here to add data to the scene T E nts Scenes
80. PG DrawHappy JPG DrawSad JPG Photo ngry JPG FhotoHappy JPG PhotoSad JPG EJ ag Cok k Col r i Ere r ET Slide F Stid Analyze Selected Media On the media browser s left list box you will be able to view a list of all the media included in the current project The media can be displayed in 4 different views Test Media Type AOI Group and Participant The Test view displays the media listed in folders by test Media Type organizes the media by type of media file e g images videos and scenes AOI Group displays a list of user created AOI groups and the media that contains the AOls that belong to those groups and Participant displays the media viewed by each project participant To toggle between the different views click the Group media by selection buttons To add media to your analysis click the Add buttons next to the items in the media list or click Add all media to add all the media included in the Test Media Type AOI Group or Participant views depending how the media is organized When the mouse pointer is placed over an item in the media list a preview thumbnail of that item is displayed When you add a media item to the analysis it will be displayed in the Selected Media list A media item can be removed from the list by clicking the Remove button To clear the Selected Media list click Remove All All items selected on the left are displayed in the Select Media list When you are
81. Read more on how to create scenes in section 5 5 of this manual pages 67 69 In many cases a web page will look slightly different each time it is presented during a recording For example if looping advertisements are displayed Tobii Studio will register each view and present them in the Web Group Tool Using the Web Group Tool you can group similar pages that contain the object of interest or group pages that contain small differences that do not impact the analysis if they are grouped together Web pages saved as a group will be shown as a single media in the media list ForSight Help Design and Record Replay Visualizations Statistics t amp EE amp amp E Export AOI Groups Web Groups Gaze Plot Heat Map Cluster Bee Swarm AOI Tool w GetStarted Download Download Spotify for Windows Premium Spotify Products overview Spotify Spotify A world of music Insta You are buying premium i r d of m usic You are buying Spotify premium z je and free Media List Filter by No Group Selected X Name C Samp Partici A Rec23 W5 P23 W Rec20 65 P20 E Rec12 Msi P12 A Rec09 E51 Pog Fl Reo 49 A Rec0 We Por E Q Rec02 W 89 P02 Check Uncheck Recordings Name Areas of Interest Start 00 00 00 000 Length 00 01 50 942 lt F Save time settings a Recordings Areas of Interest Timeline Settings AOI Overlay
82. Settings Recording Rec 01 length 00 01 47 791 participant P01 3 Drag the segment to the desired scene You can also drag it to an empty Scene pane which in turn will create a scene In addition you can drag multiple segments to the same scene 4 The new scene is updated and displays the same recording coverage as the segment 5 Open the Scene context menu and select Rename to change the name of the scene 5 5 2 Editing scenes Several segments can be added to the same scene This could be useful if the recording contains multiple instances of the same or an equivalent background To add more selections to the same scene Create a new segment selection see the previous section for details 2 Right click the new selection 3 Select Add Selection to Scene and select which scene you would like to add the selection to 4 The scene is updated and displays the recording coverage derived from the selection When a scene is created the background image is taken from the timeline marker s current location To change the background of the scene 1 Drag the timeline marker to the section of the video recording that contains the images you wish to use and choose the frame that is most appropriate to overlay the gaze activity 68 tobii 2 Click the Scene context menu arrow and then select Set new Scene Image To delete a scene 1 Click the Scene context menu arrow 2 Select Delete and then click Yes in the confirmatio
83. Studio to a Tobii Eye Tracker To verify that the Tobii Studio computer and your Tobii Eye Tracker are correctly configured check if you are able to connect Tobii Studio to the eye tracker Global Settings TT 120 204 83200394 Tobii T120 Auto TT060 204 82900384 local TT060 204 82900384 Tobii T60 Cant find your eye tracker Test selected eye tracker Delete selected eye tracker X Series Config Tool Upgrade eye tracker Eyetrackers of older models can be added manually Use 127 0 0 1 as host if you are running a Tetserver locally Host Name Optional Add eyetracker 10 tobii To test the connection 1 Start Tobii Studio by clicking the icon on your desktop 2 Open an existing project or create a new project and test for details see sections 2 1 and 2 2 of this manual pages 14 15 3 On the Design and Record tab click Setup and select Settings This will open the Global Settings dialog box 4 Select the Eye Tracker tab and click the eye tracker in the eye tracker list 5 Click Test selected eye tracker to test the connection and click OK to connect and close the Global Settings dialog box Tobii Studio is now connected to the eye tracker Earlier eye tracker models e g 1750 and X50 are not detected automatically by Tobii Studio If you are using a Tobii 50 Series Eye Tracker you need to set up the connection manually To set up the connection manually For Tobii 50 Series Eye Tr
84. The value to show here is specified in Tobii Studio This value is also used for the fixation definition Zero is the left edge the maximum value of the horizontal screen resolution is the right edge GazePointY GazePointY can be the vertical screen position for either eye or the average for both eyes The value to show here is specified in Tobii Studio This value is also used for the fixation definition Zero is the bottom edge the maximum value of the vertical screen resolution is the right edge Event Events automatic and logged will show up under Events The automatic events are start and end events for the different media mouse clicks and key presses The automatic events are listed in the event table under Event Key and Data The logged events are the manually logged events entered either in the replay view or from the remote logger EventKey Unique event key is shown for different key presses Data1 Data field for the event The contents of this field vary depending on what type of event this is Data2 Data field for the event The contents of this field vary depending on what type of event this is Descriptor Description of the event The contents vary depending on what type of event this is StimuliName The file name given to the media element when it was added to the test timeline StimulilD ClearView related data column In Tobii Studio text export the values are set to O MediaWidth Media size in pixels MediaHeight Medi
85. Tobii Technology in the United States 13 and or other countries User Manual Tobii Studio 2 X 2 1 Creating a new project In order to start designing an eye tracking test you first need to create a new project in Tobii Studio To create a new project 1 Start Tobii Studio This opens the Tobii Studio Project Library Tobii Studio Project Library R Create New Project E Import Project Archive ey Link Projectto Library Name Path Author Created E Prime C Users rms Documents Tobii Studio Projects E Prime 1 22 20109 23AM g amp Scientific Project C Users rms Documents Tobii Studio Proje Scientific Project 7 13 2009 9 13 AM C ProgramData Tobii Studio 7 9 2007 9 44 AM C ProgramData Tobii Studio Tobii Technology 4 2 2008 11 05 AM C Users rms Documents Tobii Studio Projects Tobii Training Tobii Technology 3 17 2009 1 40 PM C ProgramData T obii Studio Tobii Technology 2 18 2009 11 39AM X C ProgramData Tobii Studio 3 10 2009 10 44AM X Create new project This will create an empty project at a customizable location on your computer The Project folder will be saved in the following directory CA User wms Documents Tobi Studio Projects 3 Name the project by typing the name in the Project Name field 4 Click Browse to select the folder where the project should be saved If the folder path is not changed the project will be saved in the default folder Documents Tobii Studio Projects Description and Author
86. Tr Pi N 2 gt p t F 5 7 ee A k oe Se 7 3 eae ies Media 2viewtime MM Medianiviewtime amp E e g duration fixation 6 duration 7 duration fixation 14 total number of fixations on AOI B mean Fixation Duration on AOI B in Media 1 9 4 5 2 Brief description Duration of each individual fixation within an AOI or within all AOls belonging to an AOI group seconds 9 4 6 Total Fixation Duration seconds This metric measures the sum of the duration for all fixations within an AOI or within all AOls belonging to an AOI group thus the N value used to calculate descriptive statistics is based on the number of recordings see the N value description below for more details If during the recording the participant returns to the same media element then the new fixations on the AOI will be included in the calculations of the metric If at the end of the recording the participant has not fixated on the AOI the Total Fixation Duration will not be computed and the recording will not be included in the descriptive statistics calculations e g when computing N and means Note When browsing a website or PDF document each visited web URL and PDF page will become a unique media element 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 131 and or other countries
87. View Tools ForSight Help Design and Record Replay Visualization Print Advertisements Export AOI Groups Gaze Plot HeatMap Cluster Bee oe Diapers 01 jpg m Diapers 02 jpa FM fixationcross jpg m Juice 01 jpg Juice 02 jpg ee Er ee Extra gentle for the most senditive Skin ssccccccissssssscersssien Start with ultra sensitive skin add the chemicals and moisture of urine and stools and you have diaper rash f Newspaper Black and White jpa Media List i Newspaper Color jpg F Travel 01 jpg i Travel 02 jpa z Welcome 3 Web Groups L egueueeerr Paee gee jp m mmm m Filter by No Group Selected v Name Col Sampl O Rec 8 90 Rec7 Rec 6 Rec 5 Rec 2 Orec Rec4 O Rec3 m 1 a s D p Baby diaper s unique high absorbency natural blend cotton padding provides cotton Ege thick gel free protection for you baby s sensitive skii he chlorine free materials and absorbent polymers is non toxic and non irritating Clinically Recordings E AKERE R tested and pediatrician recommended for babies with allergies and sensitive skin Fee eee ee iPr rtrtrtrtitt ft SESS eee n Name Area 7 baby E 19 45 headline Boo wa text body Bis taaa aL o Ey dippers 7 34 J brand 362 ee eee 2 8 2 8 8 8 OR Se Ue UR UR UR UR UG UG UR E Ue Ue Ue GT Cee ee ee oe ee ee UR UR Ue UR US UR US quality statement M
88. X60 and X120 Eye Trackers setups It combines video data collected from a stand alone camera and gaze data In addition to the video device settings the Scene Camera element contains a perspective calibration tool to compensate for the scene camera s position relative to the stimulus and the user This media element cannot be combined with other elements in the timeline The typical setup consists of the following items e Some sort of physical stimulus such as a collection of objects that is moved around on a table or a panel with instruments and knobs For proper gaze recording stimuli should be positioned or moved along a 2 dimensional plane Any deviations from the plane caused by the depth of the objects placed on the plane for example will cause parallax errors in the gaze estimate e A calibration grid which is placed on the same surface that is being tracked This grid is used to calibrate the participants and to align the calibration of the scene camera perspective e A scene camera which is used to record a video stream of the scene presented to the test participant The video from the scene camera is recorded in Tobii Studio e A Tobii X50 X60 or X120 Eye Tracker and the correct settings in the configuration tool For details on the eye tracker setups and settings see the system recommendations document and the Tobii X120 amp X60 Eye Tracker User Manual e A computer with Tobii Studio Professional or Enterprise T i lt
89. a size in pixels MediaPosx Distance from the left side of the screen to the media on the screen given in pixels MediaPosyY Distance from the top of the screen to the media on the screen given in pixels MappedFixationPointX X coordinate for the fixation point mapped to the media coordinate system where the origin for the coordinate system Is the top left corner of the image media MappedFixationPointY Y coordinate for the fixation point mapped to the media coordinate system where the origin for the coordinate system Is the top left corner of the image media FixationDuration Fixation duration The time in milliseconds that a fixation lasts Aoilds ID number for the AOI usually a counter starting at zero for the first AOI AoiNames Name of the AOI or AOls if fixations on multiple AOls are to be written on the same row WebGrouplmage File name of the image file that is used to visualize the web group MappedGazeDataPointX X coordinate for the raw gaze data point mapped to the media coordinate system where the origin for the coordinate system is the top left corner of the image media MappedGazeDataPointY Y coordinate for the raw gaze data point mapped to the media coordinate system where the origin for the coordinate system is the top left corner of the image media MicroSecondTimestamp Timestamp for this export row in microseconds AbsoluteMicroSecondTimestamp Time counter timestamp in microseconds tobii Validity codes These
90. ace period of 5 days to activate Tobii Studio The License Data dialog box will appear every time when you start Tobii Studio until it has been activated If the software has not been activated within the 5 days you will not be able to run Tobii Studio without activating it Automatic activation can also be used after you have started Tobii Studio Open the Help menu in Tobi Studio s main menu and click Activate License Automatic If an error occurs a message will appear stating that you were not able to activate Tobii Studio Click the Yes button to continue to the manual activation or click No to activate automatically at a later stage To activate the license key manually 1 Start Tobii Studio In the License Data dialog box click the Activate Later button A dialog box opens informing you that Your Tobii Studio software must be activated in 5 1 days 2 Create a new project or open an existing project for details see sections 2 1 and 2 2 of this manual pages 14 15 3 Open the Help menu on Tobii Studio s main menu and click Activate License Manual to open the Manual activation dialog box 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 7 and or other countries User Manual Tobii Studio 2 X Epnme Tobii Studio File View Tools ForSight Help Report Bug Collect Logfiles to Desktop
91. ackers 1 Type the IP address of the computer running the TET Server in the Host field or type 127 0 01 address if the TET Server is running on the same computer as Tobii Studio 2 Type a name for the eye tracker in the Name field This step is optional the name can be used to easily identify the eye tracker in eye trackers list 3 Click Add eyetracker to connect to the eye tracker and display it in the list For details on how to set up the Tobii Studio computer and your Tobii Eye Tracker see the Tobii Eye Trackers user manuals 1 4 Eye tracker firmware upgrade When you start Tobii Studio and connect a Tobii Eye Tracker Tobii Studio will automatically detect if the eye tracker has the latest Tobi Eye Tracker Firmware installed If the Tobii Eye Tracker has an old version of the firmware a message window Is displayed prompting you to upgrade the eye tracker firmware Click Yes if you wish to upgrade the eye tracker firmware or No if you wish to keep the old version of the firmware To upgrade the eye tracker firmware manually in Tobii Studio 1 Open the Eyetracker Selector dialog box tab by either clicking the connection status button on the Design and Record tab or by opening the Global Settings dialog box and selecting the Eye Tracker tab 2 Select the eye tracker by clicking the eye tracker row in the Available Eyetrackers list 3 Click the Upgrade eye tracker button The EyeTracker Browser dialog box will open and the upgrade
92. aeeetsenateetas 59 5 3 Managing ana logging eveni Seninde naa teers tasvemiaaeneaeasacrceacatss 61 531 Logging evens sanio i e E AEE EEES aion ae 62 S32 ARENG EVENTS aone A E R A A taatdaah ts 63 5 4 Creating Video Segments nersini aaa a ts 64 5 4 1 Auto generating segments s ssssssssseusrsrrrunnnnnurunnnanuraranannnnnnnnnnnnnnnnnnnnanananunanununununununanannnnn anneuenn anann 64 5 4 2 Generating segments manually eeeeesssesesceseseeeeseeeeseeecseseeaeseeeeseseesesecaeseeaeseeaeseeesseeetaeeetasseeeseeneneens 65 5 4 3 Exporting segments AS VideOS vissies eec iaa aiana aaa eiaei enter Aaaa aan aaa E aaia eiaa 65 5 5 Creating scenes from dynamic CONTENA ccscecsseesssseesseseseeesseeecseeeeaeseeaesesecsesecaesecaseeasenetaeeetaeeeeansetaeas 67 Deel Creating Scenes erora e a E T O 67 S092 Edi ng SCONE anao E E SE eT eer gee roe er ee ores 68 5 6 EXO OM EMO ERCC OCICS sinana a a a a 69 9 6 1 Exporting FeCOrdings as ViIdeOS wits teehee aiaia a Waiieinl a ea ad ee Shed 69 5 6 2 Exporting the recordings as gaze data text files oe eeeeecseeseeeeeseeeeeeseeeeeeaeeeeseeeesenseeeneetaeeeteeeaenetaes 70 DeNNINOTKAUONS cea hie caseb aces ace 3s anaa de aad a Ta aa dh atedadticuastansabavecens 76 6 1 Clear View Fixation Fite nt ucisi aa aaaea iaaea do aaa aa aE Rivest 77 6 2 fo 910 ea Co 11 6 aiel Filte nedes a aa a a a aa E reere 78 Visualizing Eye Tracking Dat a s snssusnunuonnnununnununnnnunnnnunnnnununnnnunnnnununnununnnnunnnn
93. ally stopped Hement Name Extemal Video Hement Camera Capture Video Source Camera Settings Video Settings Video Codec Microsoft Video 1 Settings Edit Use video as stimulus To set device specific settings 1 If your external device is a video camera click Camera Settings to change the video image settings such as brightness and contrast 2 Click Video Settings to change other device specific hardware settings such as video size and frame rate To display the video input on the eye tracker screen during the recording select the Use video as stimulus check box Notes In most cases when capturing video the video signal needs to first be converted from analog to digital It then needs to be captured and compressed into a movie Because of this process delays may occur affecting the precision of the video synchronization At high CPU load some video capture devices occasionally drop video frames This means that although gaze data and trigger data are timed with the same precision as for all other Tobii Studio media types the synchronization of gaze data in relation to the captured video may be degraded Make sure you use a high performance computer 32 tobii Recommended computers video capture cards and codecs can be found in the system recommendations document available at www tobii com 4 1 2 7 Scene Camera The Scene Camera media element is used in combination with Tobii X50
94. alog box opens Type a group name in the Participant Group Name field Click an independent variable in the Variables list and select the values you wish to include in the participant group by selecting the check boxes in the Values list 5 You can choose to filter by one independent variable or a combination of several independent variables e g the group young Danish women can be created by using the independent variable ie 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 85 and or other countries User Manual Tobii Studio 2 X combination age nationality and gender In order to create a multivariable group repeat step 4 for other variables you wish to use to describe the group 6 Click OK to create or Cancel to dismiss the new group New Participant Group Participant Group Name Young Female Computer experience EiffelT ower Result Gender EQUALS Female age EQUALS 10 19 OR age EQUALS 20 29 OR age EQUALS 30 39 To select a participant group 1 Click the Filter by drop down list button This opens the Participant Groups list 2 Under Participant Groups select an existing group by clicking the group or create a new group by clicking New Participant Group The list of recordings will be updated automatically showing only the recordings that fulfill the group conditions To
95. an lower the computer s performance Type a value in the Screen capture frame rate field to change the frame rate of the screen recording of the participant s activities on the screen In a video recording a frame is one of the many still images that compose the complete moving picture and is usually expressed in number of frames per second The higher the frame rate the more processor resources will be consumed and the larger the size of the video file The default value for Tobii Studio is 5 frames per second FPS 158 tobii Global Settings Screen and Video Capture Miscelaneous Live viewer E Use halftone smooth video scaling Halftone scaling improves the video quality but decreases performance If you experience perfomance problems with this option enabled you could try to tum it off Screen capture framerate 5 User Camera Capture Record user camera Video Source HP Webcam 2 MP Macro kal Preview aeee Video Settings Video Codec Click for preview Microsoft Video 1 a IW Record user sound Audio Source Microphone High Definition Aud Enable live viewing Enable remote viewing E Use multicast Multicast IP address 225 1 1 111 2 Multicast is disabled by default F you want to transfer the screen capture to more than one computer on the network this option should be tumed on Broadcast Sound W Camera image oe ores To set the user camera video capture properties
96. anged in the Drawing Style Labels and Opacity sections of the AOI Overlay Settings menu More information on the settings can be found in the chapter AOI under AOI Settings See section 8 2 of this manual pages 109 110 7 9 Creating bee swarm videos The bee swarm visualization is a dynamic representation of the fixations of one or a group of participants on top of a selected media The fixation of each participant is illustrated with a colored dot This type of visualization can be used to show or analyze how the overall distribution of fixations changes over time Bee swarm visualizations can be applied directly to video movie stimuli without the need of creating a set of scenes To create a bee swarm 1 In the media list click a media element to select it 2 Select the Recordings check boxes to include the recordings in the analysis or clear the check boxes to remove the recordings Scientific Project i o File View Tools ForSight Help Design and Record Replay Visualizations Statistics t ReadingandFaces Export AOI Groups Web Groups Gaze Piot Heat Map Cluster New Scene_1 DrawAngry JPG fT DrawHappy JPG DrawSad JPG PhotoAngry JPG m PhotoHappy JPG F PhotoSad JPG m Slide2 JPG m Slide5 JPG Textil JPG Media List Filter by No Group Selected Name C Samp Partici V Rec07 93 P07 V Re 93 W Rec05 93 V Reu 94 m V T Recordi
97. ar you can select the descriptive statistic and customize the information displayed on the graph such as showing the title legend point values and setting a maximum value for the Y axis To select the descriptive statistic 1 Click the Calculate by button The Descriptive Statistics drop down list is displayed The selected value is displayed by default as the header of the list 2 Select the descriptive statistics by clicking the Mean Max Min Sum or Stdev option buttons 3 Click anywhere outside the list to close it You can choose not to show the title legend and or point values by clearing the respective check boxes Select the Set Max Value check box and type an integer value in the Set Max Value field to change the maximum value of the Y axis scale 9 3 2 Update and zoom options The bottom part of the Statistics workspace contains the Update and Zoom toolbar where you can change the zoom settings as well as toggle between automatic or manual updates of the tables and charts display 9 3 2 1 Update settings The Manual and Auto buttons control the behavior of the chart and table updates when you change a setting in the toolbars or toggle selection of items on the Data Selection panel If Manual is selected the user has to click the Update button before any changes are shown in the table or charts This allows the user to make all selections before any calculations are made which can speed up the selection process If the A
98. are images in advance check box 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 163 and or other countries User Manual Tobii Studio 2 X 2 Type the number of images you wish to preload in the field Disabling this feature clearing the check box makes the time gap between the different images heavily dependent on computer performance and resources allocated to Tobii Studio during image presentation 11 2 6 Miscellaneous settings Some dialog boxes in Tobii Studio provide the option Don t show this again When selected the specific dialog box will not appear in future similar operations Clicking the Show all warning and instruction dialog boxes button removes the check marks from all dialog boxes in which the Don t show this again option was selected Global Settings Sereen and Video Capture Eye Tracker Calibration Fixation Fitters Recording Miscellaneous Waming Dialogs od It is possible to disable some waming and instruction dialogs by checking a Don t show this again checkbox Pushing the button below will show all these dialogs again Show all waming and instruction dialogs Live viewer and track status windows e When the live viewer is dragged to a secondary screen the position of the window is saved to the application settings Pressing the button below discards thi
99. are optional fields Click Next when done tobii 5 Now give the first test a test name and if desired add a description In the next step the first test is created Type a name for the test in the Test Name field The description that can be added is optional Create first test y This will add a new test to the curent project Test Name Unnamed test Description 6 Click Create and you are ready to start designing your test If at a later point you wish to change the project information Project Name Description and Author in the Project Library click the Edit icon on the row of the project you would like to modify 2 2 Opening an existing project Once a project has been created it is listed in the Tobii Studio Project Library dialog box To open an existing project from the project list 1 Start Tobii Studio to display the Tobii Studio Project Library dialog box 2 Inthe project list double click a project to open it Alternatively click the project to highlight it and then click Open 2 3 Linking a project to the project library You can copy and paste Tobii Studio projects between different computers or disk drives and link them to the Tobii Studio Project Library This feature allows you for example to store your projects on an external hard drive while Tobii Studio is running on your computer hard drive To link a project to the project library Click the Link Project to Library button to open Windows
100. ated at the bottom of the Design and Record tab The Select Participant dialog box opens 2 Create a new participant or use an existing participant e To create a new participant type the participant s name in the Name field If you have created independent variables select the correct values if known before the test for the participant e To select an existing participant click the Use Existing Participant tab and select a participant from the participants list by clicking the participant s row 3 Click Continue to accept the selection and open the Calibration dialog box 4 Use the track status box to help adjust the participant and the eye tracker position e g chair position table or the eye tracker stand The eyes of the participants displayed as two white dots in the track status box should be in the center of the box and the distance indicator should 52 tobii display a value between 50 and 80 cm 64 cm allows for greater head movement The color of the bar at the bottom of the track status box should be green Note The color indicates whether the eye tracker is able to detect the participant s pupils Green indicates that the trackability is good and that the eye tracker is able to detect both eyes Yellow indicates that the eye tracker is only able to detect one of the pupil reflections and trackability is sub optimal Red indicates that the eye tracker is not able to find either eye Calibration ha Start Calibrat
101. ates X 5 Once all the gaze points have been moved to their new locations a second iteration of steps 2 4 is performed 6 Iterations are repeated until the gaze points are densely packed around modes and the distance between all the modes is larger than o pixels 7 Each gaze point located around the same mode value is assigned to the same cluster 8 The clusters are displayed with the gaze points in their original positions y clusters Data coordinates X This method of cluster determination ensures that the determination of the clusters is not heavily influenced by noise and outliers The other advantage of using this method is that given the choice of threshold its results are intuitive and predictable For example e Distant outliers will be represented as small clusters or discarded if no other neighboring point is present at the current threshold distance 100 tobii e Large regions of uniform density of gaze data points will display one cluster e In areas where there is a bimodal distribution of gaze data points the cluster visualization will show a single cluster if the modes for each distribution are within the selected threshold distance and 2 clusters if the modes are further apart than the threshold distance A Santella and D DeCarlo 2004 Robust Clustering of Eye Movement Recordings for Quantification of Visual Interest In Proceedings of the 2004 symposium on Eye tracking research amp applications pages 1
102. aths gaze distribution gaze response times and manual response times e Studies of autism ADHD and schizophrenia e Reading studies e Studies of ocular motor behavior and vision deficiencies A valid license key is needed to run Tobii Studio The license can be found on the Tobii Studio CD cover It can also be obtained from Tobii by contacting Tobii Support Offline help can be accessed by clicking the question mark icon in the different views in Tobii Studio The online help can also be reached from the Help menu Internet Resources Tobii Studio related material such as release notes manuals and detailed system recommendations can be downloaded from the Support amp Download section at www tobii com To download the available material you need to use your product license key or contact Tobii Support for login details You can also find other Tobii Studio materials at various social media sites such as YouTube com Tobii Studio demo and short tips videos Scribd com and SlideShare net To access those materials go to the respective website and search for TobiiEyeTracking Tobi or Tobii Eye Trackers or visit the Products amp Services section at www tobii com Additional Publications and Resources For additional information on how to use Tobii Studio you can watch the video walkthrough and practice with the Tobii Studio Tutorial Project that is included on the Tobii Studio Installation CD or downloaded
103. ation and presentation A broad range of studies is supported from usability testing and market research to psychology and ocular motor physiological experiments The Tobii Studio s intuitive workflow along with its advanced analysis tools allow for both large and small studies to be carried out in a timely and cost efficient way without the need for extensive training Tobii Studio supports a large variety of stimuli and allows both multiple and different stimuli types to be combined into a single recording A holistic view of behavior is achieved by integrating the recording of eye tracking data with user video sound keystrokes mouse clicks and other data sources into a single solution Usability studies Tobii Studio is very well suited for evaluating user experience in regard to e Websites e Software e Computer games e Interactive TV e Handheld devices e Other physical products Advertising testing Tobii Studio is ideal for testing advertising design on a variety of media e Packaging and retail shelf design and placement e Web advertising e TV commercials e Print advertising digitally scanned and presented on a monitor e Print advertising using the actual physical print Psychology amp physiology research Tobii Studio is suitable for a wide range of psychological and physiological experiments such as e Infant research e General psychological response studies including the use of scan p
104. atures in Tobii Studio such as the Visualization tab to display gaze plots and heat maps and any Windows application Tobii Studio must be minimized You can right click the recording screen and select Fullscreen to show the original recording in fullscreen mode In this case use the fullscreen controls to control the playback 9 Click the Stop button on the right side of the gray RTA bar to stop the recording or press the ESC or F10 key on the keyboard 10 The RTA recording will then be available in the recordings list in the Recordings pane Use the playback controls to view the RTA recording RTA recordings can be edited and exported just like normal studio recordings However since no gaze data is collected during the RTA recording you will not be able to use these recordings to create visualizations When you start an RTA session with your eye tracker disconnected a warning dialog box opens with the following error message No such host is known ignore the message and press OK to continue your RTA recording 5 3 Managing and logging events Events such as the image element s display time and mouse clicks are automatically registered in Tobii Studio s database and displayed in the Events list of the Recordings pane These events are also displayed on the timeline as colored bookmarks When you hold the pointer over the bookmark the event details appear If you click an event in the Events list the timeline marker will jump to t
105. below a certain threshold or to a new fixation when it rises above this threshold The location of the fixation is then determined by finding the median or mean of the X and Y coordinates from the raw data points belonging to the same fixation Global Settings Screen and Video Capture Eye Tracker Calibration Fixation Fitters Recording Miscellaneous Eye Selection Filter E Settings l Eye Selection Average Fixation Filter Fixation filters are responsible for grouping raw gaze points into fixations The two fixation filters available in Tobii Studio have their own set of J unique settings Please read the Fixation Filter help section before changing the settings Tobii Fixation Filter ClearView Fixation Filter vV Raw Data Check the checkbox to the left of the current fixation filter to make it active 76 tobii The different fixation filters can be found in the Global Settings dialog box The settings can be changed before or after the recording has taken place To choose or modify the fixation filter settings 1 On the Design and Record tab click Setup and select Settings to open the Global Settings dialog box 2 Select the Fixation Filters tab 3 Specify whether you want the Eye Selection Filter to use the average gaze point calculated from the gaze data samples from both eyes use the left eye s gaze data only or use the right eye s gaze data only Most often you should use the gaze da
106. ble and Chart views Tip Right click directly on the table or chart to select different customization commands as well as to copy and export the table or graph 9 3 1 1 Metric The Metric drop down list contains eye and mouse tracking metrics that can be calculated for each AOI or AOI group The metric you choose for the analysis will depend on the type of research question you wish to answer For a detailed description of each metric see the Metrics section section 9 4 pages 125 147 To select one or more metrics 1 Click the Metric drop down list 2 Select a metric by checking clearing the metric s check box 3 Click anywhere outside the list to close the list Tip Place the mouse over the metric to view a brief description 9 3 1 2 Rows Use the Rows drop down option box to choose how the rows in the table are displayed as well as the X axis of the charts The rows can be set to Summary only Recordings Participants or Participant Groups Rows O Summary only Recordings J Participants Participant Groups x W Show Summary Row options e Summary only Displays only the row table or bar chart that contains the values that globally summarize the data from the selected recordings and AOls e Recordings Each row represents a recording e Participants Each row represents a participant If the participant has two different recordings the results will be combined into a single row e Par
107. by selecting a color from the Background color drop down list Select the Mark as dummy media check box if you wish to exclude the image from analysis In other words the image will be shown during the presentation but it will not be possible to create a gaze plot or heat map for the image Image Element Setu p m w This element presents an image to the test participant You need to specify an image file and set the show time Alement Name Image Source Image Name sad Preview 7 2 2 Presentation Show Mouse Cursor Background color i Dummy Media F Marc as dummy media Note A media marked as dummy will not be available for analysis Properties View Time 2000 H seconds O Mouse Click Key Press To set the Image element transition during presentation select one of the following options 24 tobii e View time The display duration of the element is set by typing or selecting a time value in seconds in the View Time field At the end of the selected period the next element on the timeline will be shown e Mouse click The images are shown until the mouse is clicked This can be done by the test participant or the test leader Thereafter the next media on the timeline will be shown e Key press The images are shown until any key on the keyboard is pressed This can be done by the test participant or the test leader Thereafter the next media on the timeline will be shown D
108. ch time the media containing the AOI was viewed until the participant clicks on the AOI the other media view times are excluded from the calculations If at the end of the recording the participant has not clicked on the AOI the Time to First Mouse Click value will not be computed and that recording will thus not be included in the descriptive statistics calculations e g when computing N Note When browsing a website or PDF document each visited web URL and PDF page will become a unique media element If the Web Groups tool is used to group two or more URLs the group and not the URL will become a unique media element 9 4 19 1 N value This statistic describes the N value used to calculate other descriptive statistics such as the mean and standard deviation In the current metric it represents the number of recordings and is calculated as follows Row settings When recordings are selected as table rows the N value will always be equal to 1 If participants are selected as table rows the N value will be equal to the number of recordings that participant has made with the same media element When participant groups are selected as rows then the N value will be equal to the number of recordings included in the group Summary columns In the AOI Media Summary columns the N value represents the number of recordings x the number of AOls included in a single media element In the AOI group summary columns the N value rep
109. cipant is shown at the time the participant stopped viewing the media The color of the dots corresponds to the colors in the recordings list 7 9 1 Customizing Bee Swarms The size and color of bee swarms in the image can be customized to optimize your visualization To customize a bee swarm video 1 Drag the Opacity slider to change the opacity of the fixation dots 2 Drag the Dot Size slider to change the size of the fixation dots 3 Select the color of the dots Choose between displaying all the dots in the same color Use Custom Color and displaying the dots in their respective recording color Use Recording Colors 4 Select the Draw Activity Label check box to display a legend showing the ratio and percentage of participants looking at the image movie during a specific playback time at the top left corner of the bee swarm visualization This feature only works when the video is exported Exige gente for the most sensitive skin Start wif ultra sensitive skin add the chemicals and moisture of urine and stools and you have diaper rash Baby diaper s unique high absorbency natural blend cotton padding provides cotton soft extra thick gel free protection for you baby s sensitive skin The chlorine free materials and absorbent polymers is non toxic and non irritating Clinically tested and pediatrician recommended for babies with allergies and sensitive skin Se ae z m Q yr rE L Use Custom C
110. ck box Set the position of the legend by clicking one of the Legend position options Specify if you want to show the media name the participant filter and the time interval Time of the data included in the visualization Click Choose Font to select the font and click the Background color button to select the background color of the legend Drag the Opacity slider to change the opacity of the legend If you are batch exporting Heat Maps set the maximum value used for the color mapping by choosing between two different options Select Use current set value to set the value of all exported heat maps the same as the value of the current heat map value can only be changed and viewed prior to clicking Batch Export or Recalculate max for each media to set the maximum independent of the other heat maps being exported exports with default values If you are batch exporting Clusters select the cluster threshold settings You can either use the current setting of the Cluster viewed before clicking batch export Use current threshold or set the threshold according to a fixed percentage of the image size e g you can base this setting on the sizes of the features of the image Animated visualizations This feature is available for gaze plots heat maps and clusters You can create a video AVI with animated gaze plots heat maps or clusters overlaid on a static image This video can then be used to show or visualize how the fixation behavior of
111. cluded in the analysis The currently selected start time and duration are displayed to the right of the Media time button To set the start time and duration for data collection 1 Click the Media time button The Media Time dialog box opens Set the start time and duration for data collection Start Time 0 seconds Duration Until media end 10 Done 2 Set the start time in seconds in the Start Time field 3 If you wish to specify the duration of the data collection select the second option and specify the duration in seconds in the field Otherwise select the Until media end option 4 Confirm your selections by clicking Done Note If the start or end time of your selection is located in the middle of a fixation that fixation will be entirely removed from the metrics calculations When the Media time data selection is applied the metrics Time to First Fixation Time to First Mouse Click and Time to First Mouse Click Across are calculated from the start of the media display While other metrics such as Fixation Duration or Visit Duration are calculated within the selected interval only 9 3 1 5 Table options Tables display the AOI analyses organized by column headings such as metrics media AOI and descriptive statistics and by row headings such as recordings participants or participant groups Tables can easily be exported to TXT files or copied to the clipboard and pasted into a document
112. container or wrapper e g AVI is a commonly used container for video media in Windows The videos added to a Tobii Studio test must be in AVI or ASF format AVI is a multimedia container format introduced by Microsoft in November 1992 as part of its Video for Windows technology AVI files contain both audio and video data as well as information on audio video synchrony The first frame in each recording is time stamped and the remaining frames are recorded without timestamp information AVI containers often suffer from frame losses during coding and processing of video data The absence of time stamped frames can lead to a loss of synchrony between the audio and video streams during playback To cope with frame losses Tobii Studio s replay tool 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 27 and or other countries User Manual Tobii Studio 2 X stretches the video tracks by repeating some frames to the full duration of the playback that is stored in the database As long as the video device doesn t drop frames during the replay this approach works very well Advanced Systems Format formerly Advanced Streaming Format or Active Streaming Format is Microsoft s proprietary digital audio digital video container format especially intended for streaming media ASF is part of the Windows Media framework and contains a ti
113. count Default max count max value is set to 1 Threshold 3 x locationin pixels 5 To smooth the image and apply the color values the peak of the highest distribution is set to 1 and all the other distributions peaks are recalculated in reference to that distribution The color is then linearly mapped along the distribution with the highest value 1 red middle value 0 5 yellow and low value O green default colors can be changed 6 If you change the maximum color value in the display settings field of the heat map you change how the color is mapped to each distribution Lowering the values will produce more warm areas count max value is set to 1 Threshold 2 x location in pixels 7 lf you increase the Kernel value of the heat map you will expand the area of each cspline distribution causing more fixation color distributions to overlap and consequently increasing the size and number of warm areas on your heat map 7 6 Creating clusters The Cluster visualization is a graphic representation of areas with high concentrations of gaze data points clusters superimposed on a background image This type of visualization can be used to calculate clusters of raw gaze data that indicate regions of interest or similarly to Count heat maps display the areas with a high fixation density The fixation data contained in each cluster can be further analyzed by automatically generating AOls and calculating eye tracking m
114. ct Save as to save a new image file with the new size You can also add multiple images as well as movies at the same time by copying them to the test timeline directly from Windows Explorer To add multiple images 1 Browse to the folder in Windows Explorer that contains the images to be added 2 Select all the images you wish to add to the study for example by pressing and holding the CTRL key as you click each file 3 Right click the selection and in the context menu select Copy 4 Return to Tobii Studio Under the Design and Record tab right click the timeline and select Paste 5 In the Add Multiple Images dialog box there is a list of the file names You can preview each file by clicking the file name You can also add or remove files from this screen by clicking the Add or Remove buttons 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 25 and or other countries User Manual Tobii Studio 2 X Add Multiple Images Image Properties Diapers 01 ra Show Until Perfume 01 Color View Time 5 000 e Sec Ciapers 02 Perfume 01 Black_ white Mouse Click Key Press E Show Mouse Cursor Preview Extra gentle for the most sensitive skin ie at E Randomize Images 6 Change the order of the files by selecting the file to move and clicking the arrow button for th
115. ct how the fixation data Is visualized and the eye tracking metrics calculated in Tobii Studio but do not affect the raw gaze data To recalculate the fixation data simply change the settings on the Fixation tab The gaze data received from the eye tracker consists of gaze point coordinates distance to the eye tracker pupil size etc for the left and right eyes The accuracy of the human eye is not Identical in both eyes One of the eyes is usually more dominant and more accurate than the other In some cases the difference between the two eyes is so great that it will affect the accuracy of the analysis If so it is best to use the data from the dominant eye and discard the data from the other On the Fixation Filters tab you can choose to discard the data from one of the eyes or average the data from both eyes by clicking the Eye Selection drop down list Eye Selection Filter and selecting Left Right or Average Global Settings Screen and Video Capture Eye Tracker Calibration Fixation Filters Recording Miscellaneous Eye Selection Filter iB Settings Eye Selection Fixation Filter Fixation filters are responsible for grouping raw gaze points into fixations The two fixation fitters available in Tobii Studio have their own set of g unique settings Please read the Fieation Filter help section before changing the settings E Tobii Fixation Filter Clearview Fixation Filter Raw Data Check the checkbox to the left
116. culated by dividing the number of eye tracking samples that were correctly identified by the number of attempts 100 means that both eyes were found throughout the recording 50 means that one eye was found for the full recording or both eyes during half the time Note that the eyes cannot be found when a person is looking away from the screen this will result in a lower percentage If the test is performed so that the participant is asked questions during the recording and occasionally looks at a test leader an alternative method should be considered e Participant The name of the test participant 5 1 2 Changing the timeline scale detail and playback speed The timeline can be rescaled to show shorter time intervals This can be useful when creating segments from a long recording or when it is important to be able to advance the replay slowly 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 57 and or other countries User Manual Tobii Studio 2 X Zoom in and out on the timeline by moving the pointer to the edge of the scroll bar which is located just below the replay timeline When the pointer becomes a double headed arrow see the figure below drag the bar narrower for a more detailed timeline or wider for a better overview The playback speed can be changed to show the recording replay at a
117. d close the dialog box SN gt 4 1 4 Randomizing the presentation order of media elements The Randomize feature in Tobii Studio allows you to counterbalance the presentation order of the media elements during the recordings Tobii Studio does this by arranging the media elements selected for randomization according to a Latin Square method and holding all other media elements in their fixed position The Latin Square method allows you to control for order effects introduced by the media presentation order and position by ensuring that e Each recording contains every media element e With the appropriate number of recordings every media element can be found in all possible positions 1 2 i e Each media element is followed by each of the other media elements the same number of times Further down in this section there is a detailed description of the Latin Square design implementation in Tobii Studio Note To counterbalance for presentation order for an even number of media elements the number of recordings should be equal to or a multiple of the number of randomized media elements For an odd number of media elements you need to use twice as many or a multiple of twice as many recordings as media elements 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 41 and or other countries
118. d contact Tobii Support for recommendations 7 Click OK to accept the changes and close the Control Panel 11 1 2 Configuring a dual screen computer setup This step is only required if you plan to use your system with an extra monitor to show Tobii Studio Live Viewer and if both the eye tracker monitor and the live viewer monitor are both connected to the Tobi Studio computer Primary Screen Stimulus presentation LAN USB Network adapter VGA DVI out Tobii Studio Secondary computer Screen with a VGA Live viewer DVI dual Optional 156 output card _ a o tobii In order to use two screens your computer must be equipped with a dual head graphics card and you must have two monitors connected to this card One monitor is the eye tracker monitor where the stimuli are shown and one is a regular monitor for Tobii Studio Live Viewer To change the computer display settings Windows XP 1 Once the dual display graphics card is installed with the card specific drivers and the two screens are connected to the computer right click your computer desktop then select Properties 2 Inthe Display Properties dialog box click the Settings tab 3 On the Settings tab you should see two icons representing the two monitors Click the Display drop down list and select your external monitor 4 Select the Extend my Windows desktop onto this monitor check box 5 Click the monitor icons and drag to configure
119. displayed These two lists contain exactly the same web frames and web frame information The two lists allow you to visually compare two web frames and confirm whether the content is the same This feature also allows you to manually group web pages in a more efficient way 82 tobii To change the grouping criteria 1 Select one of the Group Criteria options e URL All frames with the same web address will be placed in the same group The gaze data for the frames will be summarized and shown on one frame The background image page is specified by selecting the image page and clicking the Set As Group Image button e URL and Size If frames have the same web address but different sizes the frames will be divided into different groups Gaze data for all frames with the same web address and the same size will be summarized and shown on one frame The background image page is specified by selecting the image page and clicking the Set As Group Image button e Name Pages with the same name are grouped pages with different URLs can have the same name e Content Pages with the same URL or name might have different content IDs Selecting this grouping option will group pages that have the same ID i e that have the same content look and URL e Manual The frames have to be grouped manually 2 To confirm whether the grouping is valid click two different web frames one in each list belonging to the same group and compare the preview imag
120. e E You are exporting the project Scientific Project as v an archive Checked content files will be exported Ea Sentence Verification Ma Rec 01 Hia Ree 02 Rec 03 Rec 04 Rec 05 Rec 06 Rec 07 Rec 08 Rec 09 Rec 10 Rec 11 Rec 12 Rec 13 Rec 14 Rec 15 Rec 16 Rec 17 Rec 18 Rec 19 Rec 20 u nu i d d al ma al nu nu al al d mu al il al d 4 Select the tests and files to export and click the Export button 5 In the next window browse and select the export location and type a file name 6 When the export is finished a confirmation dialog box will appear Click OK to exit the export process To import a project 1 Start Tobii Studio The Project Library dialog box opens 2 Click Import Project Archive tobii Import project archive Import a project archive nas file File location Import Go Click Browse to open the Windows Explorer dialog box and browse to the file to import Click the file to select it and then click Open 5 After loading you can select or unselect specific tests or files by clicking Show archive contents and selecting the files to be imported Import Project Archive Import project archive Import a project archive nas file File location C Users sms Documents My documents Software Browse i A Hide archive contents PT Checked content in project LETA course will be imported Mla Movie Test Fa Movie Resize
121. e Styles KJ Format lt 27 Filter Selec Clipboard M Font E Alignment T Number E Styles Cells Editing A3 z f How often do you use the internet G Galibi 11 JAZ S 9 GQ i B Zg Q A How often do you use the internet every day few times per week few times per month Internet u an Cut Sa aiid Ss Gop l 6 A Paste 7 Paste Special 8 Insert 9 Delete Clear Contents 11 12 Filter 13 Sort gt 14 ia Insert Comment 15 a Format Cells 16 Pick From Drop down List Name a Range 19 2 Hyperlink 20 5 Inthe Questionnaire element setup dialog box in Tobii Studio click in the Question list frame 6 Use your keyboard shortcut keys to paste CTRL V the question into the Questions list Multiple rows of questions can be added from Excel at the same time 4 1 2 9 PDF The PDF media element is used to display PDF documents facilitating the display of magazine spreads printed ads newspaper spreads and other documents that can be converted to PDF The PDF element allows participants to navigate through the PDF document using the left and right key to move back and forth between the pages in a very natural way of interaction Interactive features in an interactive PDF are not supported by the PDF element To name the PDF element 1 The software uses PDF Element as the default name You can change it by clicking in the Element Name field deleting t
122. e If necessary repeat this procedure for all frames and all the groups If frames are misplaced and the grouping thus has a strong impact in the quality of your analysis use another grouping criterion 3 Set the web group background image by clicking the web frame to select it and clicking the Set As Group Image button 4 By default the name of the group Is the same as the frame that is used as a background image Double click the group row and type a new name for the group if you wish to change tt 5 Click OK to accept the changes and wait while Tobii Studio saves the changes 6 Each group is displayed in the media list as a single media item 7 1 1 2 Manual Grouping If for some reason the frames are constantly misplaced or you want to have better control over the page groupings you can create the groups manually To assign a frame to a group 1 Select the Manual option and click New Group The new group appears at the bottom of the web frame lists Name Url Content ID Size Group Image Name Spotify A word of http www spotify com en top 298899523 1253x902 Yes You are t Spotify word of http www spotify com en 298899523 1253x902 Yes You Spotify word of http www spotify com en 339719126 1253x902 You Spotify A work of http www spotify com en get started 1040004155 1253x902 You Download Spotify for You Download Spotify f http www spotify com en download windows 62
123. e desired direction located to the right of the list 7 Choose the viewing properties in the Properties box 8 Select Randomize Images if you wish to randomize the order in which the images are presented 9 Click OK to add the images to the test 4 1 2 3 Movie A Movie element is a media element that is used to present video files to participants During the presentation videos are shown in actual size To name the Movie element 1 The software uses the video file name minus the extension once the file is added to the element You can change the element name by clicking in the Element Name field deleting the existing text and typing a new name To add a video file to the element 1 Click the Browse button and locate the video file you want to add 2 Click the video file and then select Open to add the file to the Movie element 3 Select the Mark as dummy media check box if you wish to exclude the movie from analysis In other words the video will be shown during the presentation but it will not be possible to create a heat map or bee swarm for the video 26 tobii Movie Element Setup ct This element presents a movie to the test participant You need to specify a movie file and set the end trigger Flement Name Movie Element Movie Source Movie Name Dummy Media E Mark as dummy media Note A media marked as dummy will not be available for analysis Properties Movie End Mouse Click O
124. e Enter Manual Activation Code field If successful the following message should appear Thank you for activating Tobii Studio You may now start using it 8 Click OK to start using Tobii Studio If the activation is not successful an error message will be shown Contact support and provide them with the information shown in the error message tobii 1 2 2 License deactivation Tobii Studio s license key policy also allows single license keys to be deactivated and reactivated more than once allowing you to install Tobii Studio on multiple computers and then switch between the computers However each license key can only be activated on one computer at a time To deactivate the Tobii Studio license key 1 Connect the computer to the Internet 2 Start Tobii Studio 3 Create a new project or open an existing project for details see sections 2 1 and 2 2 of this manual pages 14 15 Click Help on Tobii Studio s menu bar and then click Deactivate License Click Yes in the warning dialog box and wait until it connects to the server Click OK and Tobii Studio exits If you start Tobii Studio again you will be prompted to enter a license activation key Click the Activate Now button if you wish to reactivate your license oS 2 SS 1 2 3 How to change the license key information The License Data dialog box displays the license key and Tobii Studio edition information together with your organization name and contact e mail addr
125. easured from the elapsed time between the first and last sample included in the fixation The I VT ClearView uses a velocity threshold unit that is based in pixels instead of deg s Consequently if you wish to change the Velocity Threshold setting you need to consider the sample rate of the eye tracker as well as the image resolution when calculating the speed For example a 35 pixel radius will correspond to 35 16 6 2 11 pixels ms threshold on a 60 Hz eye tracker while on a 50 Hz eye tracker the threshold will be 35 20 1 75 pixels ms D D Salvucci and J H Goldberg 2000 Identifying fixations and saccades in eyetracking protocols In Proceedings of the 2000 symposium on Eye tracking research amp applications pp 71 78 ACM New York NY USA 6 2 Tobii Fixation Filter The Tobii Fixation Filter is a classification algorithm proposed by Olsson 2007 and is currently used as the default fixation algorithm in Tobii Studio The algorithm behaves mainly like an I VT filter that detects quick changes in the gaze point using a sliding window averaging method Assuming that the eyes move between two different fixations the following distinctions are made e fa segment of the signal is of constant or slowly changing mean value due to drift we classify it as one fixation e lf there is an abrupt change in the signal the eyes have moved to another fixation location By designing an algorithm that produces a notification whenever it detects a c
126. ecause of this delays are induced affecting the precision of the video synchronization Furthermore at high CPU load some video capture devices occasionally lose video frames This means that although gaze data and trigger data are timed with the same precision as for all other Tobii Studio media types the synchronization of gaze data in relation to the scene camera video may be degraded Make sure you use a high performance computer 34 tobii Since the stimulus that is being eye tracked is a physical object the calibration points need to be displayed on a separate calibration grid The calibration grid must have the same shape as the calibration pattern used in Tobii Studio and include either five or nine dots The calibration dots can be drawn on a paper marked on a calibration board or on the object itself It is also good to include a 25 larger active display area around the grid to make it easier to measure the parameters required in the X Series Configuration Tool See the Tobii X120 amp X60 Eye Tracker User Manual Make sure that the corners of the calibration grid are exactly 90 degrees and that the center point is exactly in the middle of the grid How to calculate the 25 larger active display area which needs to be added in the X Series Configuration Tool is described in the figure below Width lt Width x 1 25 gt tm _ Height Height x 1 25 gt _ Calibration grid PIESNE ESEI S EE TERE SRE Virtual screen 2
127. el free protection baby s sensitive skin The chlorine free materials and absorbent polymers is non toxic and non irritating Clinically tested and pediatrician recommended for babies with allergies and sensitive skin Stat 00 00 01 495 Length 00 00 01 000 At 4 seconds the animated heat map will display the gaze data from the interval between 3 4 seconds 1 second window interval e tive skin ncy natural blend e tton s cotton soft extra gel free protection itive skin T rials and on toxic on irritating Clinically commended for babies with allergies Stat 00 00 02 795 Length 00 00 01 000 5 Click OK and in the Save As dialog box choose the folder where you want to save the video The video creation progress is displayed in the Creating animation dialog box Toggle between 104 tobii displaying and hiding a preview of the animation while the video is being created by clicking the Preview button 7 8 Displaying AOI overlays on gaze plots heat maps and clusters The Areas of Interest AOI defined with the AOI tool see chapter 8 of this manual pages 108 112 can be combined with the visualizations This feature is available for gaze plots heat maps and clusters To include the AOls in visualizations 1 Click the AOI Overlay Settings button in the lower left corner of the visualization pane 2 Select the Show AOI Overlay check box Settings such as border and opacity can be ch
128. eld deleting the existing text and typing a new name 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 31 and or other countries User Manual Tobii Studio 2 X To set the video source and properties 1 Choose the video source by selecting a device form the Video Source drop down list 2 If the device has more than one input e g S video and composite specify the input you want to use for the video recording by selecting it in the Inputs drop down list 3 Choose the codec you want to use to convert and or compress the video signal during the recording by select a codec from the Video Codec drop down list The choice of codec will impact the video quality file size and CPU load during recording For most purposes the Microsoft Video 1 codec is recommended 4 Click the Settings button to set the Temporal Quality Ratio of the video compression The higher the quality ratio the better the video quality will be but the more CPU resources will be consumed 5 Click Edit to enable codecs Select the codec from the disabled list and click the left direction arrow to add the codec to the Video Codec drop down list Do the opposite to remove a codec 6 Click the Preview box to preview the video streamed from the device This element records everything that is received from an extemal video source until it is manu
129. emove websites to be displayed in ae Compatibility View Add this website Websites you ve added to Compatibility View 4 1 2 5 Screen Recording The Screen Recording media element is used to record the screen and gaze activity of the participants when using an application on the computer running Tobii Studio It is intended for use with low intensity graphics applications such as word processors or PowerPoint For applications that are more graphic intensive such as high quality movies or computer games use the Movie or External Video media element instead During a screen recording the subject is free to use any type of application on the computer To name the Screen Recording element 1 The software uses Screen Recording Element as the default name You can change it by clicking in the Element Name field deleting the existing text and typing a new name To select the application you want to test 1 Select the Run command check box Type the target path of the executable file of the program you want to run or click the Browse button to open Windows Explorer and select the executable file or program you want to run 2 Type the path of the folder where the executable file is located in the Start in field This step is optional 3 When the Run command check box is checked two more settings become available Select End screen recording when external application is closed to stop the Screen Recording element when t
130. en the Control Panel Open Hardware and Sound gt Device Manager or if you are using the Control Panel s Classic View open the Device Manager directly oe Le 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 5 and or other countries User Manual Tobii Studio 2 X 5 On the Device Manager menu bar open the Action menu then select Add Legacy Hardware to open the Add Hardware Wizard dialog box 6 In the Add Hardware Wizard dialog box click Next 7 Select Install the hardware that manually select from a list Advanced and click Next 8 Inthe devices list box click Show All Devices and then click Next 9 Click Have Disk 10 In the Install From Disk dialog box click Browse 11 Click Computer and double click the DVD drive 12 Open the Drivers and Utilities folder gt T60 T120 X60 X120 folder gt Drivers and Utilities folder gt UserCam Driver T60 and T120 folder gt Version 1 13 Select the snp2std inf file and click Open 14 Click OK in the Install From Disk dialog the driver is installed 15 Click Cancel to exit the Add Hardware dialog box and close the Device Manager program and Control Panel window 1 1 3 nstall the TET server for the Tobii 50 Series Eye Trackers In order to use Tobii Studio with the Tobii 50 Series 1750 X50 2150 you need to install the Tobii Eye
131. enas 5 1 1 ESOS nal saaa E A exsteeacnees 5 1 1 1 Install Microsoft NET and DirectX sssssssssssssesssssssssususususununnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnununnnnnnnnnnnnnnnnnnnnnnn nnna 5 1 1 2 Install the driver for the eye tracker built in user camera ssssssssssssssssrsrsrsrsrsrsrersienennnnnnnnnnnnnnnnnnnnnnnnnns 5 1 1 3 Install the TET server for the Tobii 50 Series Eye Trackers sssssssesessssrersrsesrerensnssrsrerensnsnrsrersrenenns 6 1 2 Maaa TOO I a E A AE ee eee 6 121 License key achvaliOl sneinen enion a a R ET 7 To Licem e dea NAO ea E E E E eee 9 1 2 3 How to change the license key information ssssssssssssssssssssssnununsnsnsnsnennnnnnnnnnnnununununununnnunnnnnnnnnnnnnnnnnnnnna 9 1 3 Connecting Tobii Studio to a Tobii Eye Tracker cssessscssescssssseeseeesseeesseseeseseeaeseeaesesessesesseeaeseeenaeas 10 1 4 Eye tracker firmware Upgrade aciecsirvepearanvearasi opens eenntuers ea aa 11 1 5 Updating TODI S MOO ersari a E eee 11 2 Managing Tobii Studio Projects aiciccsisistucicecsssssctecsdeessiesecestcsndsdanhucaiunadastestiniussusnsatea tons tanineiastindnteaminiaaniaeaeane 13 2 1 Creating a NEW a 68 2 6 ee en a ne ENEE En Annne Ennen ae 14 2 2 Opening an existing ProjeC sssiisissinsseiinniea ennienni aa aain iaaii 15 2 3 Linking a project to the project INDrary eeessccsceseseeseeeeeeeseeeeeeeaeeeeseeaeseeseceesesaeeeesesaeseesesaeeenseseeeesseeeneeas 15 2 4 Exporting and importing projects eeeeeeceee
132. erformed according to your study objectives This is particularly relevant if the eye tracking system is being used simultaneously in different studies or research projects and when different users have different requirements for their tests and analysis 11 1 Computer settings The Tobii T Series Eye Trackers are integrated into 17 and 24 TFT LCD monitors while the Tobii X Series Eye Trackers can be used with a wide range of screen sizes It is important that when you prepare your eye tracking study that you ensure that the computer running Tobii Studio is able to support the different screen resolutions and sizes Thus the first thing to do after installing the software and eye tracking hardware is to ensure that the computer display settings are set correctly to run the eye tracking tests Resolution based on LCD monitor size Monitor size where the stimulus is shown 1280 x 1024 1600 x 1200 1680 x 1050 1920 x 1200 The precision of the timing for example of the offset between the stimulus presentation and data recording can be improved by optimizing your computer settings for faster performance See section 13 1 of this manual pages 167 168 for information on how to optimize the eye tracking system for low offsets during data collection 11 1 1 Setting up display resolution During the eye tracking study use the same resolution and color depth on the participant screen i e the eye tracker screen for the T
133. es v DrawAnory JPG ReadingandFaces V DrawAngryEyes a 7 neutral eyes wa F DrawHappy JPG ReadingandFaces V DrawHappyEyes w ReadingandFaces M neutral eyes V neutral eyes_2 Check Uncheck E Show Not on AO Update Manual Auto 10 amp 9 m E 9 2 1 Choosing recordings The Recordings list is located on the Data Selection panel and displays all the recordings associated with the selected media The list can be used to select the recordings that will be included in the analysis Each recording is displayed as a row and contains the following information participant name recording name date and time the quality of the recording as a percentage of valid eye tracking samples and the color assigned to the recording By default only information on the participant recording and date is displayed To show the Samples and Colors columns right click the recordings list select Show Columns and then select Samples and Colors To remove a column from the Recordings list repeat the process explained above and then clear the check marks for the respective columns All the recordings are selected by default i e check boxes are selected To remove a recording from the analysis clear the check box in the Recordings list associated with that recording Click the Check Uncheck button to toggle selection of all the recordings 9 2 1 1 Filtering recordings by participant groups
134. eseeeeeeeeeeeeseeeeseeateeesecetseeaeseesesaeseesesaesesaeeassesaeeeesesaseessetaneetaetataes 16 2 5 Merging Tobi Studi Proj CIS eer ener eemererr ere arn ae 17 2 6 Deleting and removing projects from the project Ibrary sssssssesssssessssssssssssrsnsrsrnrsisisnsnsnsnsnsnnnsnnnnnnnnnnnns 18 3 Database gt fe 40 0 ee i ee a a i 19 4 Designing and Recording TeStS csesssssccsesssssesesssesceeesssseseseseeneeesesseaeseseeeeneseseseeneseseeaeeseseeaeseseeaeeseseeaenesenaeaeseseeees 20 4 1 Creaking and editing TESTS sursei niaaa ee ee ct ee cee ce eee R Ea 21 4 1 1 Adding media to a test eceesceccsceeeseesseeeeeeseeeeseeseseeseeenseeaeseeseeaesesseeaeseeseeaesessesessesaeeeseesaeeesseneesenseeeneaeas 21 4 1 2 Meda clement Ly OS e ric eect a ay etna oes re meen sap eee en seme 22 BV ECR O NAN eS mmg TOST arra aE a S E E EE EE EE 41 4 1 4 Randomizing the presentation order of media elements s s s sssssssssssssrsssrsrersnerennnrnnnnnnnnnnnnnnnnnnnnne 41 4 1 5 Unlocking Tobii Studio Tests for editing s s sesssssssssssssrensrssnsrsrensnsnnsnsnrnnnnnnnnsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnenna 43 AkO WEST GC VIS WY ieena oraaa RR ANa eraa a ea Eaa aa Taaa aa 43 A7 Oreating NEw TESIS seniorene hcg cea te ence ected cette ces denote eee 43 4 2 Managing participants and independent variables ccecesseceseeeeeeeeeeeeeeseeeeeeeaeeeeseeaseesaetateesaeeeesenaseeeas 44 4 2 1 Creating DANICIO AIS yeiceseseticxenicannceninesernsteeaetsassions
135. ess To check the license key reference and the Tobii Studio edition 1 Start Tobii Studio 2 Open an existing project or create a new project for details see sections 2 1 and 2 2 of this manual pages 14 15 3 Click Help on Tobii Studio s menu bar and then click About Tobii Studio 4 The About Tobii Studio dialog box displays information about the Tobii Studio version edition license key and whether it is activated or not About Tobn Studio Ul Tobi Studio 2 1 8 Enterprise edition Copyright 2008 Tobii Technology AB License Key License key activated Module Info Enter license key 5 To change the license key click the Enter license key button to open the License Data dialog box 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States and or other countries User Manual Tobii Studio 2 X a License Data To use the Tobii Studio software you need to provide an organization name and a valid When you have provided a valid license key you need to activate your copy of Tobii License key Enterpise edition Organization a E mail optional oa 6 Inthe License key field select the existing license key and press DELETE 7 Type the new license key 8 Click Activate Now or Activate later to close the License Data dialog box 1 3 Connecting Tobii
136. essed gt Scale to Resokdion Time limited 5 000 seconds Preview To set the image element transition during the presentation 1 Select one of the following options to set your element transition a Browse until last page The element will be displayed until the test participant reaches the last page of the PDF b Browse until F10 or ESC is pressed The PDF is displayed until F10 is pressed Thereafter the next media on the timeline will be shown If ESC is pressed the recording is stopped c Time limited The PDF element is displayed for a certain amount of time in seconds The display time can be changed by typing or selecting a time value in the Time limited box By default Tobii Studio displays the PDF document in actual size Zoom 100 It may therefore happen that the size of the PDF document does not match the test screen s size and if presented in actual size some parts of the document will not be displayed Use the Size options to adjust the PDF size for optimal viewing To set the PDF document size iF Under Size on the PDF Element Setup screen select the Zoom option to manually set the size of the PDF as a percentage of the original or select Scale to Screen Resolution to automatically have the size set to match the screen resolution 2 Click the Preview button in the lower left corner of the Setup screen to see how the stimuli will be presented during the test 3 Press ESC on the keyboard to ex
137. etrics based on those AOls 96 tobii To create a cluster image 1 In the Media list click a media element to select it 2 Select the Recordings check boxes to include the recordings in the analysis or clear the check boxes to remove the recordings Scientific Project Te Len File View Tools ForSight Help Design and Record Replay Visualizations Statistics t i w E LJ ReadingandFaces Export AOI Groups Web Groups Gaze Plot Heat Map Cluster Bee Swarm AOI Tool New Scene_1 DrawAngry JPG DrawHappy JPG P DrawSad JPG PhotoAngry JPG Ii PhotoHappy JPG PhotoSad JPG F Slide2 JPG m Slided JPG m Textl JPG Media List Filter by No Group Selected X Name C Samp Partici 7 Rec07 93 Po7 W R 93 Pos V Re05 W33 POS V Rec04 E4 Pos W Re03 E97 P03 W Rec02 W35 P02 M Reo W Po Check Uncheck Name Area V HappyEyes 120 o Boi Q oO o Areas of Interest Partici 75 Pixels Woes m cipants Change Font T Opaque O Recordings an ETE Recordings Areas of Interest E Timeline Settings AOI Overlay Settings 3 Click the Cluster button located on the Visualization header to display the cluster image 4 Save or Copy the cluster image into a document or folder on the computer To copy the cluster image right click the image and select Copy The image
138. ettings Video Settings Video Codec Microsoft Video 1 Settings 4 Adjust the five points of the polygon so that their positions match the position of the five dots on the calibration grid Do so by dragging each point over the respective calibration grid dot To ensure that the points are placed correctly over the calibration dots click the Zoom button to open the Calibration Image dialog box containing an enlarged version of the calibration image 5 Click OK to accept the changes and close the dialog box During the recording Tobii Studio records the video feed from the scene camera gaze data keystrokes and mouse clicks The gaze data X and Y coordinate space corresponds to the calibration grid area where its values range from 0 0 to the image size of the scene camera video The perspective calibration is intended to compensate for the difference in angle between the subject s perspective of the calibration grid and the scene camera However this only compensates for angles on the stimulus plane If three dimensional physical objects are used as stimuli and these have a certain height or depth that takes them far away from the stimulus plane this will cause a parallax error The size of this error is related to the difference in point of view from the scene camera and the test subject 36 tobii To minimize parallax errors it is therefore recommended that you place the scene camera at an angle fairly close to that of
139. etween either deleting a project from your disk or removing the project from the project list but without deleting it from the disk To delete a project from the disk 1 2 3 Start Tobii Studio From the Projects list in the Tobii Studio Project Library click the Delete icon 3 on the same row as the Project you wish to delete Confirm you wish to delete the project by clicking Yes in the confirmation dialog box Note When you choose to delete the project it will be permanently deleted from the disk To remove a project from the project list Po N Start Tobii Studio to view the Project Library Right click the project you want to remove On the context menu click Remove From Library Confirm that you want to remove the project by clicking Yes in the confirmation dialog box tobii 3 Database Backup Data backup is as important as the data you store on your system Backups are for your peace of mind and save you a lot of time and expense if your original data files should be damaged Your data is important for the operation of your business or research and data backup should be valued as an important procedure in your workflow In its basic form a backup is a copy of your data files to a disk or some other storage device to provide a working copy of your data that can be restored if your original data is lost damaged or corrupted This can happen in a surprising number of different ways computer virus infections
140. f this manual pages 67 69 7 5 1 Customizing heat maps Tobii Studio can produce three different types of heat maps depending on which eye movement information you wish to focus on Count total number of fixations Absolute duration based on fixation durations and Relative duration fixation duration divided by the image viewing time in each recording Gn ae x File View Tools ForSight Help Design and Record Replay Visualizations Statistics L t amp WebTest Export ot Web Groups GetStarted Download Download Spotify for Windows Premium Spotify Products overview Spotify Spotify A world of music Insta You are buying premium Media List You are buying Spotify premium Filter by No Group Selected Name C Samp Partici V Rec 23 7 Rec 20 V Rec 12 V Rec 09 V Rec 08 W Rec 07 V Rec 02 Check Uncheck Name Recordings Areas of Interest Count Style Heatmap z Counts Radius 50 pixels S abeckte diralion Color E a le to default ener ee eee eee J Relative duration Transparent Opaque Mouse Clicks Recordings Areas of Interest E Timeline Settings AOI Overlay Settings V Show Clicks V Show Legend Count heat maps show the accumulated number of fixations calculated from all the selected recordings and can be used for example to determine whet
141. finished selecting the media click the Analyze Selected Media button to close the browser or Cancel to quit the media browser without selecting a media item 114 tobii 9 2 Selecting data The Data Selection pane allows you to select the recordings AOls or AOI groups you want to include or exclude from the analysis For example you can select a subset of the recordings for analysis by using filters based on participant independent variables The Data Selection pane is divided into two distinct sections the Recordings and Areas of Interest list boxes Scientific Project Tobii Studio hn eS File View Tools ForSight Help Design and Record Replay Visualization Statistics aS Select Media Recordings Metric Time to First Fixation v Rows Recordings v Columns AOls per Media v Media time Os to media end Filter by No Group Selected O all cotcutate by Descriptive Statistics Participant Variables Cell format Participant Recordi Date RecO1 7 24 2009 9 Rec02 7 24 2009 12 Rec03 7 24 20091 T T F Q O G amp O N a Rec04 7 24 2009 1 Sel ao gi Rec05 7 24 2009 1 Rec06 7 26 2009 12 Rec07 7 26 2009 12 Rec08 7 26 2009 12 Rec09 7 26 2009 1 7 26 2009 1 Tnennne 2 Bs O n Ssisis amp amp amp amp BS ae Oo co Update Required Update i 7 emotional face a bah V neutral fac
142. from existing Independent Variable a After selecting the Create new radio button type the desired variable name Click the first row in the Answers list box twice so that the cursor blinks and type one of the answer texts Press ENTER and click the next row to add another answer b After selecting Use values from an existing Independent Variable choose the variable from the Variable Name drop down list These variables are managed under the 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 37 and or other countries User Manual Tobii Studio 2 X 10 11 Independent Variables tab of Manage Participants but can be edited for the questionnaire Change the order of the answers by selecting the answer to move and clicking the arrow button for the desired direction located to the right of the list Select the Use eye tracking check box if you wish to record the gaze data and allow the questionnaire to be used as media in the Visualizations view Click the Preview button to preview the slide Click Close to save the question slide and return to the Questionnaire element setup dialog box If desired add more questions to the same element by repeating steps 1 7 Each question with answers will be displayed on its own slide To change the order of the question slides select the question to move and click the arrow button f
143. g when computing N Note When browsing a website or PDF document each visited web URL and PDF page will become a unique media element If the Web Groups tool is used to group two or more URLs the group and not the URL will become a unique media element 9 4 22 1 N value This statistic describes the N value used to calculate other descriptive statistics such as the mean and standard deviation In the current metric it represents the number of recordings and is calculated as follows Row settings When recordings are selected as table rows the N value will always be equal to 1 If participants are selected as table rows the N value will be equal to the number of recordings that participant has made with the same media element When participant groups are selected as rows then the N value will be equal to the number of recordings included in the group Summary columns In the AOI media summary columns the N value represents the number of recordings x the number of AOls included in a single media element 146 tobii In the AOI group summary columns the N value represents the number of recordings and follows the rules described in the previous paragraph row settings In the AOI metric summary columns the N value represents the number of recordings x the total number of AOls i e all AOls included in all media elements Time from First Fixation to Next Mouse Click Across Media Measured in seconds Fixations
144. g the two monitors Click the Display drop down list and select your external monitor 4 Select the Extend my Windows desktop onto this monitor check box 5 Click the monitor icons and drag to configure their relative position 6 The eye tracker screen should be set as the primary screen monitor and the live viewer screen as the secondary Click Identify to see which screen is the primary screen 7 To set the eye tracker screen as the primary monitor select the eye tracker monitor in the Display list and then select the Use this device as the primary monitor check box Note This check box is unavailable when you select the monitor icon that is currently set as the primary monitor For some graphics cards you need to click Advanced on the Settings tab to access this function 8 Make sure the screens have the same resolution See the previous section for more information on how to set the screen resolution 9 Click OK or Apply to view the changes 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 157 and or other countries User Manual Tobii Studio 2 X Note if the Display drop down list does not show the two monitor icons then Windows is not detecting the secondary monitor Check if the cables to the monitor are plugged into the right connectors that the connection source is set correctly on your monitor and whet
145. ging it within the window AVI encoder Video codec Microsoft Video 1 Edit T Frame rate a 7 In the Save As dialog box type a file name and select the folder where you want to save it 8 Click Save to complete the process To batch export segments to videos 1 Click the Export button on the Replay header and select Movie Export 2 Inthe Batch Export Segments to AVI Clips dialog box start by choosing the folder where you want to export the videos to type the folder path or click the button to browse to the folder location a a Batch Export Segments to AVI Clips nena ee TTT File settings User camera settings Output folder C Users ms Documents m V Enable user camera PiP Opacity Pre V Enable user sound Size 320x240 Export scope Only export clips from current recording J Export clips from all recordings in current test Export clips from all recordings in all tests Export current recording Export all recordings in current test Export all recordings for all tests in current project l AVI encoder Video codec Microsoft Video 1 x Edit Frame rate 15 5 Hint Position the PiP user camer position by drag it within the window terest 66 tobii 3 Select from which recordings you want to batch export the segments in the Export Scope section You can also choose to export the recordings in full 4 Enable disable the user camera and sound in the
146. hange in the mean we are able to group the data into separate fixations When this is done we can estimate the spatial position of each individual fixation based on the information contained within its timeframe Before the fixation algorithm is applied to the data the system goes through the recording data and identifies sections with missing data The filter then interpolates the missing data for sections that have a duration below 100 ms 6 7 data points at 60Hz and breaks the recording data set into subsets when the sections are larger than 100ms The following steps are then applied to each data subset independently First a feature dif is calculated as the vector difference between two data point windows located before and after the current gaze data point Each window has a fixed number of r gaze data points and the difference is calculated using the average X and Y coordinates of these points Once dif has been calculated for all the data points in the recording we then identify peak values i e the d values that are greater than both of its two closest neighbors Next we go through the list of peaks once more and remove all the peaks that are smaller than the highest peak within a window of radius r The peaks are then added to a list under the condition that they are at least as great as a user defined threshold h Velocity Threshold The fact that the threshold is determined relative to the window size r makes the algorithm be
147. have like an I VT filter In fact the window size is fixed to 5 data points so this has the same effect as if dif had been divided by 5 and the threshold had been h x 5 for example if the Velocity Threshold is set to 35 pixels it will be equivalent to setting a threshold to 85 16 6x5 0 42 pixels ms on a 60 Hz eye tracker The list of peaks is then processed into fixations where the start and end points of a fixation are set by two consecutive peaks The spatial positions of the fixations are calculated by taking the median of the unfiltered data points in that interval After the location of each fixation has been determined the fixation data goes through a final iteration First the Euclidean distances between all the fixations are calculated and if the distance between two consecutive fixations falls below a second user defined threshold a Distance Threshold the two fixations are merged into a single fixation The process is repeated until no 78 tobii fixation point is closer to each other than the threshold The fixation identification process is then complete Fixation Filter Fixation filters are responsible for grouping raw gaze points into fixations The two fixation fiters available in Tobii Studio have their own set of a unique settings Please read the Freation Filter help section before changing the settings Help Tobu Fixation Filter Clearview Fixation Filter Raw Data Check the checkbox to the left
148. he color drop down list 4 Select the element s background by selecting the Color option and selecting a color from the list or by selecting the Image option and locating an image file on your computer 22 tobii Instruction Element Setup This element presents an instruction to the test participant This stimuli can also be used as a pause in the recording FAlement Name Instruction Element Preview Text Font i Color ki Image Properties D View time 5 seconds Mouse click Key press Space El Show Mouse Cursor Enable for visualizations To choose how the instruction ends and moves to the next element select one of the following options from the Properties area e View time The Instruction screen will be displayed until the set time has expired To set the duration select a predetermined time value in seconds in the View Time field e Mouse click The Instruction screen will be displayed until the mouse is clicked by either the test participant or the test leader e Key press The Instruction screen will be displayed until a key on the keyboard is clicked by either the test participant or the test leader Click the Key press drop down list and select a key from the list Select the Show Mouse Cursor check box to display the mouse cursor on the screen during presentation of the Instruction Select Enable for visualizations to enable eye tracking during the
149. he existing text and typing a new name To add a file to the PDF element 1 Click the Browse button to open the Open dialog box 2 Locate the PDF file you want to add and click it 3 Click Open to add the file to the element screen A preview of the document is shown below the PDF file name field 4 Specify whether the PDF should be presented as single paged or as double paged side by side Magazine 5 Skip this step if you have selected Single paged Select the Show front page as single page check box to display the first page of the PDF as a single page or like a book cover 6 Click the Advanced button to open the PDF Advanced Settings dialog box to change the background color and to select whether or not to Show page numbers during the PDF presentation select Show page numbers 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 39 and or other countries User Manual Tobii Studio 2 X PDF Element Setup ve This element presents a PDF document to the test participant You need to specify a PDF file and set presentation style Element Name PDF Element PDF Source File name Preview Presentation Style Single paged Double paged side by side Magazine Show front page as single page Properties Size Browse until last page Zoom 100 C Browse until F10 or Escape pr
150. he participant exits the application Or select Close external application when screen recording ends In this case the element is ended by pressing F10 on your keyboard or stopping the test with ESC If none of the options above are selected the element is ended with F10 and the application is closed separately 4 If the Run command is left unchecked the application has to be started by the test participant or the test leader When the recording starts Tobii Studio is minimized and the Windows desktop or any program that is opened on the desktop is displayed Note If the Run command is not selected press F10 to move to the next element or ESC to stop the test 30 tobii Screen Recording Setup This element records everything that happens on the screen until it is manually stopped by pressing F10 or Escape Hemert Name Run Application Open File E Run command Start in Note The following commands are not applicable when the designated file is opened by an already running application End screen recording when extemal application is closed Close extemal application when screen recording ends using F10 or Escape While the Screen Recording element is active Tobii Studio records gaze data a video of the screen content keystrokes and mouse clicks The video is recorded in the screen s resolution 4 1 2 6 External Video The External Video media element is used to present and record video and sound from an ex
151. he position in the recording where the event occurred You can enable or disable the types of events displayed in the list by right clicking the list and selecting Show In the Visible events and log categories dialog box select the event boxes you wish to display in the list a gt SGentihic Project Tobi Studio 211 atl eo xX File View Tools ForSight Help Design and Record Replay Visualization Statistics ReadingandFaces Generate Export RTA Name v Samples Rec 06 1235 28 PM Rec 10 7736 2009 O Rec 03 gO Rec 01 EO Rec 02 2 Rec 05 O Rec 04 O Rec 03 O Rec 42 O Rec 43 iS nd The Eiffel Tower is an iron tower built in Q i x eo a 1889 in PariseFrance It W8s naimed after a rere ye its Bsigner Gustave Hifet and the Queston nded oocn 0soss Whats tallest building in Paris It was originally 2 Sa 00 00 06 122 What is your I QuestionEnded ooooo93a0 Matis your supposed to be built in Barcelona Spain ScreenRecStop 00 00 10 443 ped The entire building weighs about 10 000 ImageStart 00 00 11 247 Slide2 JPG KeyPress 00 00 19 297 Space tons User Cam 00 00 22 740 F gender age Side2uPG Y aispG Eiieno Insuuction Elem Text2P_ Cot_ Inst _ S Pho_ S Dra S Pho S Dra_ S Pho S Dra_ a m uma m jaj min m m m a a m m a m j m gt B l 5 vam A AS SCS IS naa 00 00 00 000 90 00 11 000 90 00 27 000 00 00 33 000 00 00 44 000 00 00 55 000 90
152. he threshold is treated as a saccade point and discarded This fixation filter also allows you to set a minimum fixation duration i e fixations with a duration below the Duration Threshold value will be discarded from the analysis This feature can be used for example to discard involuntary fixations from your data set based on a duration threshold Fixation Filter Fixation fiters are responsible for grouping raw gaze points into fixations The two fixation fiters available in Tobii Studio have their own set of a unique settings Please read the Freation Filter help section before changing the settings Help E Tobii Fixation Filter ClearView Fixation Filter Raw Data Check the checkbox to the left of the curent fixation filter to make it active El ClearView Fixation Filter Settings Velocity Threshold 50 Duration Threshold 100 Velocity Threshold Velocity Threshold piels sample Highest velocity allowed within a fixation Default is 5I pivels sample Click help button for details 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 77 and or other countries User Manual Tobii Studio 2 X The location of the fixation point is determined by using the mean of the X and Y raw gaze data points The timestamp of the fixation is taken from the first sample included in the fixation and the duration is m
153. he two white dots representing the eyes should be shown in the middle of the track status window and the status color bar on the bottom should be green 4 Click Start Recording to start the Tobii Studio recording the start recording procedure is the same as starting a recording in Tobii Studio 5 Create a new participant or select an existing participant e To create a new participant type the participant s name in the Name field If you have created independent variables select the correct values if known before the test for the participant e To select an existing participant click the Use Existing Participant tab and select a participant from the participants list by clicking the participant s row 6 Click Continue to accept the selection and open the Track Status dialog box 7 Click Start to initiate the calibration process 8 Before the first calibration point appears on the screen instruct the participant to look at the points as they move across the screen Note The test participant does not have to keep his her head still during calibration 9 The calibration process will stop automatically when all the calibration points are shown 10 Click Accept to accept the calibration results or Recalibrate to recalibrate one or more calibration points 11 In the Start Recording dialog box enter a name for the recording be sure to use informative names and check the track status to confirm once more that the participant is co
154. heat maps calculated The heat map image can either be based on fixation data or raw data depending on if you are using one of the two fixation filters or the raw data filter In both cases the data entries consist of a timestamp duration and spatial location X and Y coordinates information Eye tracking raw data is composed of fixation and noise data points The noise includes eye samples during saccades and other small fixation related movements Thus a heat map based on raw data will contain more noise and show larger areas with the high color value When a heat map is based on raw data each entry corresponds to a raw gaze point from the eye tracker sampled each 16 17 ms interval for the 60 Hz system The sample interval will be 8 9 ms for a 120 Hz system and 20 ms for a 50 Hz system The duration values for each entry are constant as they are defined by the duration of the sampling interval When the input is based on fixation data the eye tracker will group the raw data entries into fixations and the duration of each fixation depends on the fixation filter used to identify the fixations The input data will typically look like this Fixation 1 Start 132 ms Duration 132 ms Location 415 711 Fixation 2 Start 264 ms Duration 735 ms Location 711 491 Fixation 3 Start 999 ms Duration 101 ms Location 301 10 7 5 2 1 Basic concept The first step in creating a heat map is to map the fixation on the image This is done by goi
155. her participants have seen different elements on a 90 tobii stimulus image or website Each fixation made by each participant adds a color value to the fixation map and the value is the same regardless of its duration Absolute Duration heat maps display the accumulated fixation duration on different locations in the image and can be used for example to measure the amount of attention or cognitive processing dedicated to different elements in the image Each fixation made by each participant adds color values to the fixation map according to its duration in seconds The Relative Duration heat map displays the accumulated fixation duration on the different elements in the image relative to the total image viewing time In other words if in recording A the subject looked at the image for 10 seconds and at a specific object for 3 seconds and in recording B the subject looked at the image for 10 minutes and at the specific object for 3 minutes then the data from recording A and recording B will have the same weight on the final heat map This type of heat map should be used when the view time per stimulus is not fixed such as during a web usability study where participants typically spend different amounts of time on each web page Each fixation made by each participant adds a duration value to the fixation map and the values are divided by the participant s view time The relative values for each participant are then added and the maximum
156. her your computer s graphics card supports dual view See the manual for your monitor for more information Windows 7 1 Once the graphics card is installed with the card specific drivers and the two screens are connected to the computer open the Windows Start menu and select Control Panel 2 Inthe Control Panel find the Appearance and Personalization category and click Adjust screen resolution 3 The Change the appearance of your display dialog box displays the information on how many monitors you have connected to the computer and which screen is set as the primary Display 1 and which is set as the secondary Display 2 4 Click the Multiple displays drop down list select Extend these displays and then click OK Note If the option Multiple displays is not shown in the dialog box Windows is not detecting the secondary monitor Try clicking Detect to automatically detect the monitor If Windows still cannot find the monitor then check if the cables to the monitor are plugged into the right connectors and that the connection source is set correctly See your monitor manual for more information 5 To set the eye tracker screen as the primary monitor select the eye tracker monitor in the Display list and then select the Make this my main display check box 6 Make sure that the screens have the same resolution See the previous section for more information on how to set the screen resolution 11 2 Tobii Studio Global Settings dial
157. here the height of each bar indicates the descriptive statistic value for a pre chosen metric e g mean fixation duration or maximum fixation duration This value can be displayed on top of each bar by selecting display of Point Values Each bar in a chart represents an AOI AOI group or AOI summary all AOls The categories on the X axis are determined by the row settings in the Statistics toolbar The Y axis variable is determined by the metric setting For example when Fixation Duration is selected the unit will be in seconds while with Fixation Count it will be in counts The title of the chart is centered just below the upper border of the chart and displays the name of the metric and descriptive statistic used to generate the chart The chart legend is displayed on the right side 124 tobii of the chart area and shows the color code of the bars in the chart and the respective AOI AOI group or AOI summary all AOls names When you select participant groups the chart will also display summary bars all participants This bar is calculated using the data from all the recordings included in all the participant groups When you select multiple metrics each metric will be displayed in its own chart Use the scroll bar to view the different charts Above the chart area you can view a brief description of the metrics used to generate the charts The chart properties are available when you click the Chart dl button On the toolb
158. ht Help i Design and Record Visualization Statistics k Q t Generate Export RTA Name a Date f sre buying Spotty premium Windows Intemet Eeclorer o Rec 01 59 TIS hnps wwwspatiy comen products prermum order accourt ORecorrta 1309 sls asec ces BS mete Right Keak A 89 0 Rec 02 Rec 02 RTA Rec 07 6 25 2009 Rec 07 RTA 12 1323 PM Rec 08 10 38 46 AM O RecosRTA ee Mm 0 How would you like to pay 71112003 g Fec 03 120514Pm 51 Serion a iV amp Rec O9RTA 39 36 15 pm 0 me TL Win Ta ao 9 Q Type Time ScreenRecSiart 00 00 00 000 Recordings You are buying premium 2 Create your Spotify account d uestionStarte 00 00 00 251 What is your it you wish to add Spotity premium to an existing account please iog er QuestionEnded 00 00 04 564 What is your s QuestionStarte 4 99 94 g94 How often do amples JSmth raksmorgas P2 d 00 00 04 you use the int ow often do QuestionEnded 00 00 09 401 OAA 00 00 09 434 QuestionEnded 00 00 17 209 QuestionState 00 00 17 244 you use the int ow often do you listen to m ow oft you listen to m o you listen to music on your Y ka sak a Sweden lhe country selected needs to be the same as your credit card is registered Gender Gender Mobile phone Mobile service provider User Cam Dom internet Protected Mode Off TRAE fcs CB m 4 a gt we 00 Ape
159. ht axis directly out from the eye tracker plane e PupilLeft Pupil size left eye in mm The distance and pupil size measurements are calculated to be as close to real values as possible However individual differences in the eyes of subjects and the strength of glasses contact lenses will cause errors in these values The measurements still reflect changes in head position and pupil size accurately e ValidityLeft Validity of the gaze data The validity is O if the eye is found and the tracking quality good If the eye cannot be found by the eye tracker the validity code will be 4 Read more under the Validity codes section further down e Gaze PointXRight The horizontal screen position of the gaze point for the right eye 0 is the left edge the maximum value of the horizontal resolution of the screen is the right edge e GazePointYRight Vertical screen position of the gaze point for the right eye 0 is the bottom edge the maximum value of the vertical resolution of the screen is the right edge e CamXRight Horizontal location of the right pupil in the camera image 0 is the left edge 1 is the right edge e CamYRight Vertical location of the right pupil in the camera image 0 is the top edge 1 is bottom edge e DistanceRight Distance from the eye tracker to the right eye The distance is given in mm ona straight axis directly out from the eye tracker plane e PupilRight Size of the pupil right eye in mm The distance and pupil
160. i Studio Statistics tool click the Statistics tab The Statistics tab is divided in three main areas e Statistics header Allows you to select media for analysis copy tables and charts to the clipboard and export tables and charts e Data Selection pane This is where you can select recordings and chose which AOls to include in the analysis e Statistics workspace This is where you can select the metrics create and view tables and charts and change the statistics settings and properties 9 1 Choosing media for the analysis The Select Media for Analysis in Project dialog box allows you to view and select the media for the analysis Only media with Areas of Interests AOls will be available for analysis To open the media 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 113 and or other countries User Manual Tobii Studio 2 X browser click the Select Media button on the Statistics header or the Select Media button at the center of the Statistics window Select Media for Analysis in Project Scientific Project Group media by Test Participant Selected Media Remove All Only media with Areas of Interests Als can be analyzed 2 Em Media 4 AQKs T m ReadingandFaces Add all media in this test 42 o Recordings 0 rr ADI Groups E DrawAnary JPG Remove E DrawHappy JPG Remove DrawAngry J
161. i Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 139 and or other countries User Manual Tobii Studio 2 X Summary columns In the AOI media summary columns the N value represents the number of recordings x the number of AOls included in a single media element In the AOI group summary columns the N value represents the number of recordings and follows the rules described in the previous paragraph row settings In the AOI metric summary columns the N value represents the number of recordings x the total number of AOls i e all AOls included in all media elements Percentage Clicked Participant 1 amp Participant 2 Measured in k hh hh Participant 2 clicks Participant 1 clicks Participant 1 clicks on AO A in Media 1 5n AO B in Media 1 on AOI A in Media 1 N of recordings where the participant clicked on the AOI at least once Total N of recordings x 100 Percentage Clicked e g Fixated for AOI A 100 Clicked for AOI B 50 9 4 16 2 Brief description Percentage of recordings in which participants clicked at least once within an AOI or AOI group 9 4 17 Mouse Click Count count This metric measures the number of times the participant left clicks with the mouse on an AOI or an AOI group If during the recording the participant leaves and returns to the same media element then the new mouse clicks on the media wil
162. iaia con ery peaa ra TESS PEI ee Pidasin peie hkg ve pb cosy eria pta a hae Ea Pesdicts piegre Gpp Hu ee peaa corner phasi rea 1P 12 Spoby A zki of a Spotly A ovoid of i ilari rpa arad hee Gish A wold of blige ew toby ooo Bios ETI pE Yii Tpi A mabi o uat alan iania arei hiis He eaa ipak comer Blog SEIT 1E Yei pn ir TF SPAS IA ve Cech A eed of muse aii uc adhe higuina ope conven eee HL Ym pa A amb of hep ew p comer Jenn 134 egip A mai of mu bien ode o hts aapediy commen STE Ve Sooty A wab of hipassa paie Bamia 1 8 a Seok A mid af mume aisi greed amd ies His iaaa ppa eam en Spel aare iign Ted Ta se hyng ipui You ae byrg Soniy parar Tou met bang Sp hiipi vessa ipai conten pai prera ones oari Fatta n Ts Yen Tou me bung Spotily premii hice poii comlen poductoipemauniceden accu 2 ii Ye Tou we bang Sp hiipii pai con enpeoducte prera oaar 1 Sees 12a You me busing Spotty premaum hin ewe poii conan producte pemmumicdetaccmum DSM tte Tou me baying Sp h tcwreapetiy pan mu padci param ada aan ii 1k TEU e baning Sot oem his apco morada oema ede SA PA z sis Tow se bung Sp hoes renumetly momen madu manum is account TET Wake vG e 4170 A world of music miisi kripir eel from A warid of music Halil Prois arc bui Free Day pass Premium tow r ar e igre a Erm inw Set Aa Gra iraga Fite Virsien Set a Grou mage W ce When you click a row in the list a preview of the web page is
163. ieri Ne Gross Sees Here Coley Samp O rez E z 0 Re EA O Ret ETI if 5 6 Fre 0S i i Re oe as jE recor bt CLAR e Gescanonce Ssi DODO s legh 00i 4 Save line mamii ce reste ena Seriar Atv Seon To create a gaze plot 1 From the media list in the Selection pane click a media element to select it 2 Select the Recordings check boxes to include the recordings in the visualization Uncheck to remove the recordings 3 Click the Gaze Plot button located on the Visualization header to display the fixation plot 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 87 and or other countries User Manual Tobii Studio 2 X 4 Save or Copy the heat map into a document or folder on the computer To copy the gaze plot right click the image and select Copy The image is copied to the clipboard and can be pasted into a document by using the document editor Paste controls To save the gaze plot image right click the image and select Save Image as In the Save Image dialog box select the folder and the file name Select the type of image file JPEG BMP or PNG Click Save and the Information Legend Settings dialog box opens Choose the settings of the gaze plot legend and click Save Note The selected media has to be a still image If the media is a screen recording or a movie
164. ifferent configurations of computer hardware and stimulus that have been used to test the stimulus display timing offset These tests measure the offset between the Tobii Studio recording timestamps and the stimulus display on a screen All setups show that the offset between Tobii Studio timestamps and image or video display is below 50 ms Table 5a Test results for the offset of the start time of the stimulus display tests were performed with the stimulus size set to the eye tracker native screen resolution and using a Dell Precision T5400 desktop computer type of stimulus number format codec amp Windows version Se Single image 4 images JPEG BMP T120 sequence Single video a T120 XP 228 dviX T120 32 5 Yo XviD T120 XP 315 AVL Techsmith T120 Vista Classic 2147 MV1 T120 Vista Classic 185 oo me aoe XviD T6OXL Vista Classic 36t This test was performed using Dell Precision M6300 laptop computer This test was performed using Dell Precision M6400 laptop computer Windows Vista appearance settings optimized for better performance 166 Table 5b Test results for the offset of the start time of the stimulus display display connector graphics card and type of computer Dell Precision T5400 desktop M6300 and M6400 laptop Single image Nvidia M6400 Single video DVI Nvidia T5400 T120 XP BE Nvidia M6300 T60 XP 359 Graphics card Nvidia NVidia
165. ight be running in the background anti virus software firewall software anti spyware software Skype or other chat communication programs Ideally use the computer only to run Tobii Studio tests and analysis e t may help to disable or disconnect Bluetooth WLAN Wifi and network connectors and to remove CDs or DVDs from disk drives e Use a direct connection between your computer and Tobii Eye Trackers For more information on how to connect the computer and Tobii Eye Trackers see the section entitled Connecting Tobii Eye Tracker in your eye tracker user manual e Use images and movies as stimuli using the recommended formats and codecs see Table 7 below e Disable Live Viewer User Sound and User Image from the user camera e Don t run your study at excessive screen resolutions Choose something reasonable for your purpose Higher resolutions take up precious video RAM and increase the time for clearing the frame buffer drawing your stimulus and for post processing operations e Optimize Windows 7 Vista or XP for better performance For more information visit http windows microsoft com en us windows vista Optimize Windows Vista for better 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 167 and or other countries User Manual Tobii Studio 2 X performance section_6 or http www microsoft com
166. ii Studio version number 4 Follow the on screen prompts and instructions to complete the installation Start Tobii Studio by clicking the icon on your desktop to launch Tobii Studio Alternatively click Start menu gt All Programs gt Tobii From the Tobii menu select Studio and then click the Tobii Studio application The first time you run Tobii Studio you will need to provide the license key to run the software s tobii To uninstall Tobii Studio Open the Windows Start menu and select All Programs Click Tobii gt Studio Click Uninstall Tobii Studio Follow the on screen prompts and instructions to remove Tobii Studio eS 1 2 1 License key activation When you use Tobii Studio for the first time start by typing the license key in the License key text field After typing the license key you have the option of selecting either Activate Now or Activate Later e f your computer is connected to the Internet type your organization name and an e mail address in the respective fields and then click Activate Now The activation process Is initiated and you can start using Tobii Studio once it is completed e lf you do not have an Internet connection regardless of whether not you will in the future click Activate later Activate instalation naw License key Enterprise editon expres 11 13 2009 Organization Tobi E mail optional Activate Now Activate Later By clicking Activate Later you have a gr
167. ill be equal to the number of recordings that participant has made with the same media element When participant groups are selected as rows then the N value will be equal to the number of recordings included in the group Summary columns In the AOI media summary columns the N value represents the number of recordings x the number of AOls included in a single media element In the AOI group summary columns the N value represents the number of recordings and follows the rules described in the previous paragraph row settings In the AOI metric summary columns the N value represents the number of recordings x the total number of AOls i e all AOls included in all media elements 9 4 13 2 Brief description Number of visits within an AOI or an AOI group count 9 4 14 Visit Count zero count This metric is calculated in the same way as Visit Count with the exception that if at the end of the recording the participant has not fixated on the AOI the Visit Count value will be registered as zero and the recording will be included in the descriptive statistics calculations e g when computing N and means 9 4 14 1 Brief description Number of visits within an AOI or an AOI group count 9 4 15 Percentage Fixated This metric measures the number of recordings in which participants have fixated at least once within an AOI or AOI group and expresses it as a fraction of the total number of recordings It is calculated by divid
168. in advance stabilizes and minimizes the time gap between the images However the preparation will consume more memory during a recording Disabling it entirely will result in gap times heavily dependent on the computer s speed A value between 1 and 3 should be sufficient in most cases Default is 1 V Prepare images in advance 1 image s Tobii Studio initiates the stimulus presentation by sending a command to the computer s graphics card to write the stimulus data to its memory The speed at which the stimulus is written on the graphics card is affected by different factors such as the type and size of the stimulus the computer s processor usage and speed the RAM allocated to this command and the graphics card speed and available memory Once this process is completed the stimulus is sent to the monitor via a VGA or DVI connector The Recording Settings for time gap between Images feature allows you to select whether you want to preload a certain number of images before initiating the image presentation Preparing the images in advance shortens the gap between the presentation of the different images and keeps that gap constant However preloading the images might introduce a short delay at the start of the stimulus presentation as it requires more memory to process several images One or three images should be sufficient to ensure a smooth presentation To set the number of images you want to preload 1 Select the Prep
169. in the United States 89 and or other countries User Manual Tobii Studio 2 X To create a heat map 1 In the media list click a media element to select it 2 Select the Recordings check boxes to include the recordings in the analysis or clear the boxes to remove the recordings 3 Click the Heat Map button located on the Visualization header to display the heat map 4 Save or Copy the heat map into a document or folder on the computer To copy the heat map right click the image and select Copy The image is copied to the clipboard and can be pasted into a document by using the document editor Paste controls To save the heat map image right click the image and select Save Image as In the Save Image dialog box select the folder and the file name Select the type of image file JPEG BMP or PNG Click Save and the Information Legend Settings dialog box opens Choose the settings for the heat map legend and click Save If you wish to use a higher resolution background image in your report or publication you can also save the heat map layer without the background image Right click the heat map select Save Heatmap Layer Image As and save it as a PNG file to preserve the transparency Note Selected media has to be a still image If the media is a screen recording or a movie still images have to be defined before a heat map can be drawn This is done by creating scenes read more about how to create scenes in section 5 5 o
170. ing the total number of recordings in which participants have fixated within the AOI by the total number of recordings in the test 9 4 15 1 N value This statistic describes the N value used to calculate other descriptive statistics such as the mean and standard deviation In the current metric it represents the number of recordings and is calculated as follows Row settings When recordings are selected as table rows the N value will always be equal to 1 If participants are selected as table rows the N value will be equal to the number of recordings that participant has made with the same media element When participant groups are selected as rows then the N value will be equal to the number of recordings included in the group Summary columns In the AOI media summary columns the N value represents the number of recordings x the number of AOls included in a single media element 138 tobii In the AOI group summary columns the N value represents the number of recordings and follows the rules described in the previous paragraph row settings In the AOI metric summary columns the N value represents the number of recordings x the total number of AOls i e all AOls included in all media elements Percentage Fixated Participant 1 Participant 2 Measured in Fixations on media size indicates duration ae ee pm 2 20 000 O 00O JOOG Media 2 view time Medi 1 view time oog Partici
171. ion 5 Instruct the participant to look at the points as they move over the screen 6 Click Start to initiate the calibration process The first calibration point appears on the screen Note The test participant does not have to keep the head still during calibration 7 The calibration will stop automatically when all calibration points are shown 8 When the calibration is finished the calibration results are displayed in two vector plots in the Calibration Result dialog box ke Calibraton Result le Cahbraton Result Ponts Martved for Recahbraton Problem Calibration pointmissing Problem Large errors in calibration Perfect calibration Solution Selectandrecalibratethe Solution Check eye tracker setup missing point glasses and participant Make new calibration The calibration plot shows error vectors green lines the size of each green line indicates the difference between the gaze point calculated by the eye tracker and the actual dot position Recalibration of certain points should be made if the lines are long or if there are no lines at all at a certain point 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 53 and or other countries User Manual Tobii Studio 2 X If the calibration was unsuccessful the calibration result Not Enough Calibration Data will be displayed If this
172. is copied to the clipboard and can be pasted into a document by using the document editor Paste controls To save the cluster image right click the image and select Save Image as In the Save Image dialog box select the folder and the file name Select the type of image file JPEG Bitmap or PNG Click Save and the Information Legend Settings dialog box opens Choose the settings of the cluster legend and click Save 5 Generate AOls based on clusters by right clicking the cluster image and selecting Export Clusters to AOls The new AOls will be displayed in the Areas of Interest list Note Selected media has to be a still image If the media is a screen recording or a movie still images have to be defined before a cluster image can be drawn This is done by creating scenes read more about how to create scenes in section 5 5 of this manual pages 67 69 7 6 1 Customizing clusters The size and number of clusters in the image are affected by the Distance threshold settings The Distance threshold parameter is a spatial value that determines the minimum distance between two different clusters for more details see the next section 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 97 and or other countries User Manual Tobii Studio 2 X To change the Distance threshold 1 Click the Settings button in the lower
173. is is where you can select the media recordings and AOls used to produce the visualizations e Visualization panel This is where you can view the different visualizations draw AOls view the recording timeline and change viewing settings 80 tobii To create a visualization 1 Inthe Selection pane from the media list click a media element to select it 2 Now select the Recordings check boxes to include the recordings in the analysis Clear the check boxes to remove the recordings 3 Click a visualization icon on the Visualization header to display the results in the Visualization pane The timeline below the visualization shows the total time the media was displayed during the recording If the participants have different view times e g when browsing a website or a PDF document the longest view time is used to determine the timeline scale The duration of each individual recording is indicated by a colored dot that is coded with the color shown next to the recording in the Recordings list 7 1 Selecting media When you click the different visualization icons the media list will only display the media elements that can be analyzed using the selected visualization tool For example if you recorded video stimuli those elements will not be displayed in the media list when you are viewing gaze plots heat maps or clusters Video media elements need to be processed into scenes first to be able to use those types of visualizations
174. isits a participant has made to the AOI If the participant has made more than 1 recording with the same media element N will be equal to the sum of the number of visits in all the recordings 134 tobii If participant groups are selected as rows then N will be equal to the sum of the number of visits of all the participants included in the group Visit Duration Measured in seconds s d f Me N 2 4 Gy Ma Nicat D j f aN f a ko 5 IN A AS Media 2 view time ES e g duration of the 1st visit to AOI B duration of the 2nd visit to AOI B Summary columns In the AOI media summary column the N value represents the total number of visits to all AOls included in a single media element In the AOI group summary column the N value represents the sum of the visits to all the AOls belonging to the same AOI group and follows the rules described in the previous paragraph for recordings participants and participant groups In the AOI metric summary column the N value represents the total number of visits to all AOls included in all media elements 9 4 10 2 Brief description Duration of each individual visit within an AOI or an AOI group seconds 9 4 11 Total Visit Duration seconds This metric was called Observation Length in older versions of Tobii Studio and measures the duration of all visits within an AOI or AOI group In this case the N value used to calculate desc
175. ist and in the timeline 5 3 1 Logging events In addition to the automatic logging of events events can be logged either manually on the Replay tab in Tobii Studio or using the Tobii Studio Remote Logger during a test see chapter 10 of this manual pages 149 155 to learn more about this feature However before events can be manually logged a coding scheme must be defined i e you need to create a set of user defined events and associate each event to a specific key on your keyboard To define a coding scheme 1 Open the Design and Record tab 2 Click the Setup button and select Coding Scheme Coding Scheme Use this dialog to define an event coding scheme Logged events are used to search and automatically extract video segments during replay A description and a shortcut key can be assigned to each event The quick logging column tells if you want to be able to add free text comments while logging Quick logging Color E 3 Click a row in the Description column and type the name of the event 62 tobii 4 On the Shortcut drop down list select the keyboard key you want to use to log the event 5 Select Quick Logging if you want to prevent the log message dialog box from appearing when you click the key in the Replay tab New Log Message scene 1 start OK Cancel The New Log Message dialog box allows you to type a comment that will be associated to that specific event or to select another event
176. isualizations or metric based descriptive statistics 4 2 1 Creating participants Participant data is stored under the project level in the Tobii Studio hierarchical system Participant information thus only needs to be entered once and a certain participant would be able to have multiple recordings and take different tests as long as the tests belong to the same Tobii Studio project Participant data can be exported as a tab delimited TXT file and this file can then be imported into Microsoft Excel To create participants before performing the recording 1 Either go to Tools on the menu bar click Participants and then click Manage Participants or click the Setup drop down button next to the Test button and then click Manage Participants 2 Inthe Manage Participants dialog box under the Participants tab click New 44 tobi 3 In the Create Participant dialog box in the Participant Name field type the participant s name or other form of identification that you will use to refer to the participant 4 If you have already created independent variables and know the information about the participant select the correct values from the drop down list for the respective independent variables Participant Name Jane Doe 5 Click OK to add the participant and his her information to the participants list in the Manage Participants dialog box To generate an arbitrary list of participants no information besides name 1
177. it the preview If the size is not ideal repeat the two previous steps 40 tobii 4 1 3 Editing an existing test After adding elements to the test timeline you can change the initial test design by easily deleting or editing existing media elements To delete a media element 1 Right click the media element 2 Select Delete from the context menu 3 Click OK in the confirmation dialog box if you are sure you want to delete the element To copy a media element 1 Select the media element or elements to copy To select multiple media elements click and hold the CTRL key while you click each media element To select many consecutive elements click the first element in the sequence and then press and hold the SHIFT key while clicking the last one All the elements between the two clicks are selected including the two clicked 2 Right click the media element Select Copy from the context menu 4 Click the media element in the timeline that you would like to paste after to the right of and select Paste from the context menu Go To change the position of a media element in the timeline 1 Select the media element or elements 2 Drag the media to the new position in the timeline To edit the media element presentation properties Right click the media element Select Edit in the context menu The Media Element Setup dialog box opens Make the necessary changes to the media element Click OK to accept the changes an
178. ive statistics table or chart and depends on the Statistics or Table and Charts toolbar settings Metric Time to First Fixation x Rows Recordings x Columns AOls per Media Media time Os to media end m d Calculate by Descnptive Statistics x _ Participant Variables Cell format Update Required Update Manual Auto 100 LAJ m A By default when you change a setting on the toolbars or toggle selection of items in the Data Selection panel the central section of the Statistics workspace will turn dark and you need to click the Update button to recalculate and display the table and or chart To change the setting to automatically update when a setting has been changed click Auto next to Update in the lower left corner of the Statistics workspace The Statistics toolbar is located at the top of the Statistics workspace and displays several drop down list boxes These list boxes allow you to select eye tracking metrics and set general row and column settings related to the organization of the data in the tables and charts In addition you can also select which portion time interval of the media view time you wish to analyze by selecting a start time and duration value 118 tobii The Table and Chart toolbar is located in the top section of the Statistics workspace just below the Statistics toolbar Click the Table pn and Chart ill buttons on the toolbar to toggle between the Ta
179. ive statistics calculations e g when computing N Note When browsing a website or PDF document each visited web URL and PDF page will become a unique media element If the Web Groups tool is used to group two or more URLs the group and not the URL will become a unique media element 9 4 20 1 N value This statistic describes the N value used to calculate other descriptive statistics such as the mean and standard deviation In the current metric it represents the number of recordings and is calculated as follows 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 143 and or other countries User Manual Tobii Studio 2 X Row settings When recordings are selected as table rows the N value will always be equal to 1 If participants are selected as table rows the N value will be equal to the number of recordings that participant has made with the same media element When participant groups are selected as rows then the N value will be equal to the number of recordings included in the group Summary columns In the AOI media summary columns the N value represents the number of recordings x the number of AOls included in a single media element In the AOI group summary columns the N value represents the number of recordings and follows the rules described in the previous paragraph row settings In
180. k boxes 3 Click anywhere outside the list box to close it Column levels in tables AOls per Media Each cell contains the descriptive statistic value for a single AOI or a single AOI group The cell value calculation also depends on the Row option selection The data is displayed using the following column hierarchal order metric gt media gt AOls and or AOI Groups gt Descriptive Statistics Example below 2 images DrawAngry JPG and DrawHappy JPG 4 AOls DrawAngryEyes DrawHappyEyes and 2 neutral eyes Row option Recording Time to First Fixation DrawAngry JPG DrawHappy JPG DrawAngryEyes neutral eyes DrawHappyEyes neutral eyes N Mean Sum N Mean Sum N Mean Sum N Mean Sum Count Seconds Seconds Count Seconds Seconds Count Seconds Seconds Count Seconds Seconds Recordings Rec 01 i 0 53 0 58 1 2 14 2 14 1 0 77 0 77 1 1 19 1 19 AOI Media Summary Each cell in the AOI Media Summary columns contains the descriptive statistic value for all the AOls present in a single media element The cell value calculation also depends on the Row option selection The data is displayed using the following column hierarchal order metric gt media gt All AOls groups the data from all AOls present in each media gt Descriptive Statistics Example on the next page 2 images DrawAngry JPG and DrawHappy JPG 2 AOls DrawAngryEyes and neutral eyes Row option Recordings 120 tobii Time to First Fixation DrawAngry JPG
181. l be shown If the calibration went well click Accept and the Recording Start dialog box opens Important note The calibration is performed after the space bar is pressed Make sure that the test subject doesn t move his her gaze at the sound of the space bar press 4 3 1 3 Infant Calibration Infant calibration is used when conducting studies on infants Small animations in AVI format are displayed where the dots normally appear This works as an attention grabber suitable for small children It can also be used when it is difficult for someone to follow the calibration instructions 50 tobii Tobii Studio can also display different AVIs to attract the test subject s attention if they begin to respond poorly or grow tired of the calibration AVI These items are called attention animation AVIs No calibration data is generated during the display of these AVIs To change the Infant calibration settings 1 Type the calibration stimulus file path into the Calibration Animation field or Click the button to locate the file you want to use Click the file and then click Open to select it as a calibration stimulus 2 Type the file path into the Attention Animation field or click the button to locate the file you want to use Click the file and then click Open to select it as an attention grabbing stimulus 3 Select the Show infant calibration instructions check box to view the calibration instructions during the calibration procedu
182. l as across multiple media and across tests The group is treated as a single AOI and the metrics will calculated as a single entity AOI groups are created and managed on the Visualization tab 110 Screntfe Propect Tobin shure File View Took Foght Help vad Em sl ee a ACI Groups Gaze Plot HeallMap Chester Bee Seracm Ol Taal Ml ioannas E OrewHeppy JPG aie DrewSad_ JPG E Photodegey JPG _ Phonan JPG Ie PhotaSad J lait li JPG Side PS i Texti JPG PG Web Groups Fiher b Ne Gioup Selssiaid Name Ree to lw he 0 a 0 Ree 01 E E 0 Ree 02 EIG Arc 05 A Gp Rec Oe A Pee oa iM Rec 22 Areas of Interest Cobar To create an AOI group 1 2 3 2010 Tobii Techn Click the AOI Groups button on the Visualization header under the Visualization tab The View AOI Groups dialog box opens View AOI Groups New AOI Group 1 neutral face gt la emotional face gt neutral faces gt newgroup OK Cancel Click New AOI Group to create a new group A new AOI group row is created In the field type a name for the AOI group This name will be used to identify the AOI group in the Statistics tool Click OK to create the AOI group ology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 111 a
183. l be included in the calculations of the metric If at the end of the recording the participant has not clicked on the AOI the Mouse Click Count value will not be computed and the recording will not be included in the descriptive statistics calculations e g when computing N 140 tobii 9 4 17 1 N value This statistic describes the N value used to calculate other descriptive statistics such as the mean and standard deviation In the current metric it represents the number of recordings and is calculated as follows Row settings When recordings are selected as table rows the N value will always be equal to 1 If participants are selected as table rows the N value will be equal to the number of recordings that participant has made with the same media element When participant groups are selected as rows then the N value will be equal to the number of recordings included in the group Summary columns In the AOI media summary columns the N value represents the number of recordings x the number of AOls included in a single media element In the AOI group summary columns the N value represents the number of recordings and follows the rules described in the previous paragraph row settings In the AOI metric summary columns the N value represents the number of recordings x the total number of AOls i e all AOls included in all media elements Mouse Click Count Measured in counts Mouse click on media 7 hh Mouse
184. l eyes Row option Recordings Time to First Fixation Fixation Duration All Medias All Medias All AOIs All AOIs N Mean Sum N Mean Sum Count Seconds Seconds Count Seconds Seconds Recordings Rec 01 4 1 i7 4 68 amp 0 44 2 64 X axis levels in charts AOls per media Each bar represents the data from an AOI belonging to a single media element The bars are organized by media Row option selection and then AOI AOI Media Summary Each bar represents the data from all AOls present in a single media element The bars are organized by media and then Row option selection 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 121 and or other countries User Manual Tobii Studio 2 X AOI Group Summary Each bar represents the data from an AOI group calculated for all the selected media The bars are organized by Row option selection and then AOI group AOI Metric Summary Each column represents the data from all AOls and all media The bars are organized by Row option selection 9 3 1 4 Selecting a time interval for analysis Use the Media time button in the Statistics workspace to restrict the analysis to a specific time interval of your recording This is done by first selecting the start time of the interval and then by defining the duration of the interval These settings will be applied to all recordings in
185. left corner of the Visualization pane to open the heat map settings menu 2 Inthe Distance threshold area type a value in pixels in the field to set the Distance threshold To change the font of the labels 1 Click the Change Font button the Font dialog box opens 2 Click on the respective lists to select the font type Font list style Size effect and Script 3 Click OK to close the dialog box and accept the changes To change the cluster image opacity and percent information 1 Drag the Opacity slider to change the opacity of the clusters 2 Select which Percent Display Style to display for the clusters Participants displays the percentage of participants that have contributed with gaze data to the cluster Recordings displays the percentage of recordings that have contributed with gaze data to the cluster Like gaze plots and heat maps clusters are dependent on the fixation filters settings Fixation filters are responsible for determining the number size and location of the fixation dots Read more about fixation filters in chapter 6 of this manual pages 76 79 7 6 2 How are clusters calculated Simple clustering algorithms calculate the distance between any two points in the data and allocate them to the same cluster if the distance is below a certain pre determined threshold such algorithms are known as distance cluster algorithms The algorithm behind the Tobii Cluster visualization is based on the robust clustering a
186. lgorithm suggested by Santella amp DeCarlo 2004 for eye movement data analysis Essentially the cluster algorithm tries to find spatial patterns in the distribution of the gaze data It does so by first moving the gaze points into denser configurations until the points are collected around mode values and then after a number of iterations when the distances between the mode values are larger than the distance threshold it assigns each gaze point located around the same mode value to the same cluster This procedure is summarized in the following algorithm where o represents the distance threshold or spatial scale X y Spatial Kernel x y CXxp gt O Cluster calculation 1 The distance threshold is set to o pixels 98 tobii Distance threshold y ae Data points Data coordinates X 2 The algorithm calculates an area based on the o pixel radius around a gaze data point and then calculates an average X and Y coordinate using the neighboring gaze points within that area y x Data points Data coordinates X 3 The gaze data point is moved to the average X and Y location 4 Steps 2 and 3 are performed for each gaze point present in the data 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 99 and or other countries User Manual Tobii Studio 2 X y H Data points Data coordin
187. lick Import Project Archive Click Browse to open the Windows Explorer dialog box and browse to the file you want to merge Click the file to select it and then click Open After loading you can select or unselect specific tests or files by clicking Show archive contents and selecting the files to be imported If there are any conflicts a new dialog box opens This dialog box displays the merging options and the projects that can be merged Select Merge on import into the following project and select which project to merge with If you are not sure if you should merge the project select Save as a new project in the library instead The two projects will then be kept as two distinct projects in the database studio has detected that there are one of more projects in the library with the same project ID as the project you are trying to import You may either import this as a new project or merge it into one of the projects listed below Please select one of the options below wish to import Sentence venfication nas by the following method D Save as anew project in the library Merge on import into the following project Name Path Creator CreationDate Linguistics Sentence verfic C ProgramData Tobii Studio Tobii Techno 3 10 2009 Click OK when you are ready to merge or save the two projects 2 6 Deleting and removing projects from the project library In the Tobii Studio Project Library you can choose b
188. lly showing only the recordings that fulfill the group conditions To create a new participant group Click the Filter by drop down selection button This opens the Participant Groups list Click Create new participant Group The New Participant Group dialog box opens Type a group name in the Participant Group Name field Click an independent variable in the Variables list and select the values you wish to filter the participants by in the group by clearing the check boxes in the list under Values 5 You can choose to filter using one independent variable or a combination of several independent variables e g the filter young Danish women can be created by using the independent variable combination age x nationality x gender In order to create a multivariable filter repeat step 3 for other variables you wish to use to describe the group 6 Click OK to create the group or Cancel to dismiss the new group lS To edit an existing participant group 1 Click the edit button to the right of the group name in the Participant Groups list This opens the Edit Group dialog box 2 Change the group name in the Participant Group Name field 3 Click an independent variable in the Variables list and select the values you wish to include or exclude in the group definition by selecting the check boxes in the list under Values 4 Repeat step 3 for other variables you wish to change 5 Click OK to accept edits or Cancel to dismiss the cha
189. m all recordings in current test C Export clips from all recordings in all tests C Export current recording 0 Export all recordings in current test O Export all recordings for all tests in current project AV encoder Video codec Microsoft Video 1 7 Edit Frame rate 1 S Hint Fosition the FiF user camer position by drag it within the window prm 3 Select to export only the current recording or all the recordings from a test or all the recordings in the Project 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 69 and or other countries User Manual Tobii Studio 2 X Enable disable the user camera and sound from the video export Select the user camera opacity and size Select the codec you want to use to produce the video Type or select the frame rate of the video export Click OK to initiate the batch export of the video files ot OF 2h 5 6 2 Exporting the recordings as gaze data text files The output format of the text export is a tab separated text file This file format can be opened using Excel SPSS Matlab or any text editor of your choice To export the data 1 Click the Export button on the Replay header and select Text Export 2 Inthe Text Export dialog box start by choosing the folder you want to export the videos to by typing the folder path in the Output folder
190. me The time measurement starts when the media containing the AOI is first displayed and it stops when the participant fixates on the AOI When using AOI groups the time measurement stops when the participant fixates on any of the AOls belonging to the group If during the recording the same media is displayed several times with other media in between the Time to First Fixation value will be calculated by adding each display time of the media containing the AOI until the participant fixates on the AOI the display time of other media shown in between are excluded from the calculations If at the end of the recording the participant has not fixated on the AOI the Time to First Fixation value will not be computed and that recording will thus not be included in the descriptive statistics calculations e g when computing the N value Note When browsing a website or PDF document each visited web URL and PDF page will become a unique media element If the Web Groups tool is used to group two or more URLs the group and not the URL will become a unique media element 126 tobii 9 4 2 1 N value This statistic describes the N value used to calculate other descriptive statistics such as the mean and standard deviation In the current metric it represents the number of recordings and is calculated as follows Row settings When recordings are selected as table rows the N value will always be equal to 1 If participants are selected a
191. mestamp for each media frame facilitating media synchronization even in situations when frames have been dropped during recording In this case synchronization will still be maintained as best as possible by trying to match each frame timestamp with the data timestamp The frames that are dropped are replaced by the previous frame during playback of the recording The video data block contains video and audio and can be encoded using different codecs A codec is software or a device capable of encoding and decoding video data In Tobii Studio this process is accomplished using Microsoft Windows media framework DirectShow DirectShow is a multimedia framework and API programming interface responsible for performing various operations with media files or streams in a Windows environment such as encoding or decoding some common media file formats Microsoft Video 1 and MP3 are standard codecs installed on all Microsoft computers The Tobi Studio installation includes the Techsmith codec If you wish to use other codecs you must ensure that the correct video codecs are installed Tobii Studio does not support installation of codec packages 4 1 2 4 Web The Web media element is used to display websites to participants In order to use this element during a recording your computer needs to be connected to the Internet or the websites need to be stored locally on your computer Tobii Studio uses the website s URL or a local address to open the
192. n click Open to add it to the project list Double click the project to open it eS It is advisable that you regularly back up your Tobii Studio projects 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 19 and or other countries User Manual Tobii Studio 2 X 4 Designing and Recording Tests Tobii Studio procedures for test design recording and analysis are organized in an intuitive way that allows you to perform both small and large studies in a timely cost efficient manner without extensive training The process is as follows you start by designing and recording the test on the Design and Record tab under the Replay tab you can view and edit the recording as well as code events visualizations and Areas of Interest can be created under the Visualization tab and finally calculate and display eye tracking metrics based on AOIl s using the Statistics tab In this chapter we will focus on how to design and record tests using the Design and Record tab After you have created a project and test you are presented with the Design and Record tab This tab contains efficient timesaving tools for designing tests managing participant data performing calibrations and recording eye gaze as well as media presentation data File View Tools ForSight Help Design and Record Replay Visualization Statistics a
193. n dialog box to confirm To delete a content section of a scene 1 Right click the content you want to delete from the scene 2 Click Delete scene segment 5 6 Exporting Recordings Your eye tracking recordings can be exported in two distinct formats as a gaze overlay video showing the stimulus presentation playback together with the participant s gaze overlay and as a tab delimited text file that contains timestamp information of the gaze data eye tracking samples pupil size data and other recording related events The text export can be used to analyze the data recorded by Tobii Studio in an external analysis or statistics program such as Excel SPSS or Matlab 5 6 1 Exporting recordings as videos Recordings are exported into an AVI video format that can then be viewed using an external media player This export procedure is the same as exporting segments as videos To export the videos 1 Click the Export button on the Replay header and select Movie Export 2 Inthe Batch Export dialog box start by choosing the folder where you want to export the videos to Type the folder path or click the button to browse to the folder location Batch Export Segments to AVI Clips A File settings User camera settings Output folder C Users mms Documents V Enable user camera PiP Opacity eee ae V Enable user sound Sizet 370240 Export scope Only export clips from current recording C Export clips fro
194. n on Tobii Studio timing of stimulus display as well as Tobii Eye Trackers sample timing information is available upon request Contact Tobii Support or your sales representative in your area to obtain a copy of Timing Guide for Tobi Eye Trackers and the eye tracking software whitepaper 168 SOl si e 1S 9 dd jenuew si jo a g Uogos peay Bopp sBull1es jeqo 5 24 Jo qe sbuljjos Buipuooey 94 ul paziwozsno q ueo synopoys pueoghey esau uol eZI ensi A Ke doy SUO ITEISAGO DUIMO O y OULINDP pesn oq uep J p1099H uBisoqg skey USAF Heq fod opns 11qo josloid e uodo yooloid Mau e N nyoe yO9 oid yodu ayoe yOoloid yodxg S9 yOO UL SUIJOLUI ISO OY WO PIDOW 9 9 0Qq SUI OLUI 1SO OY UO NWS elpsw 9 Sed SUIJOLUI 4S9 SY WO NWS elpew Adog Kes Wass 0 OIPNIS NGO SZIWIUI snjyejs J921 oy U dO JOMAIA VAI e90 94 UGdO Kejdei ay esned Ae de1 usedJ9s n Sujet y ejds q Aejde1 uses9s n esoUed asn y Aeldsiq Ae de1 uses9s n Ayoedo esowed sasn y esees0eEq Aejdes uaeos n Ayoedo eieweo Jasn y eseesou Qe OIDNIS 11IGO SNOIAeJd 94 0 SACI yoeqhe d Bulpsooe1 ey Bunnp puimey pesned usym puim owes Qe OIPNIS IIGO x9U y 0 SAO yoeqhed Bulpsooes y Buunp premio se pesned usym soueApe owe NWS epa M N nws eipaw x u y 0 0ULAPY djay MAIAOIC 4S9 4x4 Kejdai u 198S n y 4x4 Buip10991 4 PNO uo1 ouny
195. n the Recordings pane there is a list of all the recordings made in the selected test By default Tobi Studio displays in the recordings list the name of the recording the quality of the recording as a percentage samples and the participant that was recorded You can also display more information about the recording To make more information about the recording visible in the Recordings list of the Recordings pane 1 Right click anywhere on the recordings list 2 Select Show in the context menu 3 Now select one at a time the information you want to display in the list The title of the column is at the top of the list To sort the list by a recording detail Right click anywhere on the recordings list Select Sort by in the context menu Choose the element to sort by Click the respective column headings to change the sort order You can also click the heading you want to sort by and click again to reverse the sorting Oy gt Types of information that can be shown in the recordings list e Name ID of the recording can be modified in the recordings list by clicking the ID e Date The date and time when the recording was made e Duration The duration of the recording in seconds e Color The color used to identify the recording on the timeline in the visualizations under the Visualization tab can be changed in the recordings list by double clicking the color e Quality The quality of the recording is cal
196. nclude gaze data media presentation events e g media start and stop times mouse clicks and key presses and recording elements e g videos from screen recordings or video capture devices Each recording is associated with a participant and his or her unique calibration Recording 1 Recording 2 Recording 3 R o m w penn a t The project and test structure of Tobii Studio allows you to perform an experiment with different tests on the same group of participants For example if you wanted to conduct an experiment using a factorial design you can have multiple tests within a single project where each test contains the same media but in a different order Or for A B comparison testing each test could contain different media representing the different alternatives Visualizations are created based on the recordings belonging to their respective tests You can consequently only create a heat map for individual tests within a project even if the same image can be found in more than one of the tests However the Statistics tab can be used to perform cross test analysis within the same project For example you can group Areas of Interest AOI belonging to media located in different tests and use that group to extract descriptive statistics based on eye tracking metrics 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of
197. nd X50 are not detected automatically by Tobii Studio If you are using a Tobii 50 Series Eye Tracker you need to set up the connection manually Type the IP address of the computer running the TET Server in the Host field or type 127 0 01 as the address if the TET Server is running on the same computer as Tobii Studio Type a name for the eye tracker in the Name field optional that can be used to identify the eye tracker in eye trackers list Click Add eye tracker to connect to the eye tracker and display it in the list 11 2 3 Calibration Settings See section 4 3 1 in this manual pages 48 52 to learn how to change the calibration settings in Tobii Studio Screen and Video Capture Eye Tracker Calibration Fixation Filters Recording Miscellaneous Calibration Type Regular Manual Infant Foreground Color Calibration Speed Medium Restore default Area and Points Number of calibration points A points Spons points Background Color IL Restore default Calibration Area Configure Restore default 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 161 and or other countries User Manual Tobii Studio 2 X 11 2 4 Fixation filter settings The Fixation Filters tab allows you to configure the gaze data and fixation filter calculations These settings affe
198. nd or other countries User Manual Tobii Studio 2 X To view the content of an AOI group 1 Click the AOI Groups button on the Visualization header 2 Expand the desired AOI group by clicking the Right Arrow button on the left side of the AOI group row The names of the AOls belonging to the AOI group are displayed below the group To delete an AOI group 1 Click the AOI Groups button on the Visualization header 2 Click the Delete button amp in the AOI group row To create an AOI group from an AOI 1 Right click an AOI in the Areas of Interest list or click the settings button SF for the respective AOI 2 Select AOI Groups in the menu and click Assign to new group The Create new AOI Group dialog box opens In the field type a name for the AOI group This name will be used to identify the AOI group in the Statistics tool Click OK to confirm the creation of the AOI group When you click the settings button F next to an AOI name in the Areas of Interest list and select AOI Groups from the menu a list of the existing AOI groups will be displayed A check mark is displayed to the left of the group name if that AOI is included in an existing group To add an AOI to an AOI group 1 Click the settings button next to the AOI name in the Areas of Interest list 2 Select AOI Groups in the menu and click the AOI group you want to assign the AOI to To remove an AOI from an AOI group 1 Click the settings button F next
199. nd the test names and the second level a list of the individual AOls belonging to that media Each AOI row contains the AOI name a check box that you can select or clear for AOI analysis and the color used to display the AOI in charts The color of an AOI can be edited by clicking the color button and selecting a color from the color palette Click the Check Uncheck button to toggle selection of all the AOls Note that clicking the Check Uncheck button toggles selection of the individual AOls and does not influence the AOI groups Selection of an AOI group is toggled by clicking the check boxes associated with the AOI group 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 117 and or other countries User Manual Tobii Studio 2 X Select the Show Not on AOI check box to include fixation or mouse click data that is not included in any of the AOls in the analysis The not on AOI data will be displayed per media The Statistics workspace consists of toolbars for defining how the data is presented in the tables and charts You can select AOI metrics create and view tables and charts and change the statistics settings and properties The results from your AOI analysis are displayed in the central section of the Statistics workspace This section is called the Statistics Display Area The analysis output can be a descript
200. ndependent variable using the Manage Participants dialog box 1 Go to the Independent Variables tab in the Manage Participants dialog box by clicking the Setup drop down button 2 Click Manage Participants and then the Independent Variables tab 3 Click New Overview Use this form to define data associated with participants A typical example is to define oo the variable Gender that can take two values Male and Female This data can be used in the analysis to filter recordings based on combinations of variables and values 4 Inthe Add New Participant Variable dialog box type the variable name e g gender in the Variable Name field 5 Click an empty row in the Values list until you see the cursor blinks Type a value e g male female 6 Repeat step 4 until you have entered all the values 46 a tobi WF Add New Participant Variable Variable and Values A participant vanable must have a name and one or several values Add or edit values by double clicking in the cells or pressing F2 in a selected cell Vanable Name Gender Values Male Female 7 Click OK to save the variable and values to the variables list in the Manage Participants dialog box For more information on how to create participant independent values using participant interaction see the Questionnaire media element section of this manual section 4 1 2 8 pages 37 39 To learn how to create participant groups and
201. nformation s sussusuesusnunnununnunnununnunnununnunnunnnnunnnnunnunnnnnnnunnunnnnnnnunnnnnnnnnnnnnnnnnnnnnnn annen 166 PGE AROCOMMMENM AU ONS eeina E a E rat asnnente opecicns 167 tobii 1 Installing and Updating Tobii Studio The objective of this chapter is to instruct you in how to install and update Tobii Studio on the computer you are going to use to record eye tracking data For details on how to set up Tobii Eye Trackers or Eye Tracking hardware please see the respective user manuals For optimal performance Tobii Studio should be installed on a computer that follows the Tobii Studio and Tobii Eye Trackers System Recommendations This document is available at www tobii com Support amp Downloads section or can be obtained from your local sales representative Tobii Studio software can be used to incorporate much more than just recording of eye tracking data Various video and audio streams and integration with other software and hardware may also be utilized Make sure that when you use additional components such as video capture cards and cameras that you have the correct drivers installed on your system 1 1 Before installation Tobii Studio uses Windows programming components drivers and eye tracking firmware e g APIs and frameworks to display and record the eye tracking data and stimulus These components must be installed on the computer before installing Tobii Studio Tobii Studio is compatible with Windows XP Vis
202. ng through all the fixations in all the selected recordings one by one and adding their values whenever a fixation shares the same X and Y pixel location as another see the figures below If we chose Count we add the number of fixations at the same location If we are using Absolute duration we add the duration of each fixation For Relative duration the duration of each fixation is divided first by the media viewing time and then added Heatmap Count Heatmap Count image image x y pixels xy pixels Once all the fixations values have been added together color values are added to all the points with the warmest color representing the highest value 92 tobii Heatmap Count xy pixels _ However this basic process would result in a rather useless image with small colored dots distributed over the image What we do instead is add color values to all the points within a certain distance of the fixation location and the color values gradually decrease as we move away from the fixation point This process ensures that the color distribution results in a more smooth heat map image and gives some biological relevance to the color mapping 7 5 2 2 Tobii Heat Map The distribution of values around a fixation point is accomplished by using an approximation to the Gaussian curve that is commonly used in 2D image processing a Cubic Hermite Spline polynomial
203. nges 116 tobii To delete an existing participant group 1 Click the delete button to the right of the group name in the Participant Groups list 2 Confirm your deletion by clicking Yes in the Delete Filter dialog box If you wish to cancel the deletion click No 9 2 2 Selecting Areas of Interest The Areas of Interest list is located in the data selection panel and displays all the Areas of Interest AOI and AOI groups that were drawn on the selected media aj Areas of Interest AQ Groups ual emotional face ba V neutral faces Individual AOls Y mM DrawAngry JPG ReadingandFaces DrawAngryEyes y neutral eyes w M DrawHappy JPG ReadingandFaces DrawHappyEyes u W neutral eyes m DrawSad_JPG ReadingandFaces DrawSadEyes 7 neutral eyes y neutral eyes_2 Check Uncheck Show Not on AOI AOI groups are listed first and are separated from individual AOls by a list divider Each AOI group row contains the name of the group a check box where you can toggle selection of the group for analysis and the color used to display the group in charts The color of an AOI group can be edited by clicking the color button and selecting a color from the color palette Note AOI groups will only be available for analysis if all the media containing the AOI groups are selected The individual AOls are displayed per selected media in a two level collapsible list The first level contains the media a
204. ngs Re02 E97 Rec02 E957 QO Rec0i mm 94 Check Uncheck Name Area 7 AngryEyes 91a Areas of Interest 00 00 01 883 St an a 00 00 01930_ 00 00 02 482 Recordings Areas of Interest View Settings 3 Click the Bee Swarm button located on the Visualization header to display the video 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 105 and or other countries User Manual Tobii Studio 2 X 4 Click the play button to start the bee swarm video Use the stop and pause buttons to control the playback of the recording 5 Click the export button located to the right of the of the playback buttons to export the video In the BeeSwarm Export Setup dialog box specify where you want to save the video file type the destination path or click Browse to open the Save BeeSwarm file as dialog box to select the folder and type the file name Click the Video Codec drop down list to select the codec to use to encode the video file and type a frame rate value in the Frame Rate field to choose the video s number of frames per second Click OK to export the video file On the timeline in the lower part of the visualization pane the total gaze time of all participants is visualized with a drop out graph In this graph a color dot representing each parti
205. ngs button to open the gaze plot settings menu Drag the Opacity slider to change the fixation dot opacity Select the Show Number check box to display the fixation order number of the fixation dots Select the Same Size check box to set the size of the fixation dots so that all the dots have the same diameter Checking this option removes the time information fixation duration from the gaze plot but can be redisplayed by clearing the check box ao ae 88 tobii 5 Select the Show Borders check box to display a line around each fixation dot When this option is selected the first and the last fixation of a recording will display a thick line and fixations with dotted lines represent periods when continuous viewing of the media was interrupted An interruption can take place when for example the eye tracker loses track of the eyes e g the participant looked away from the screen or when the participant leaves and returns to the same media element after viewing another media element in between 6 Click the Border Color box to the right of Show Border to open the color palette The default is a white box and white border Select a color for the line around the fixation and click OK 7 Select the Show Clicks check box to display the participant s left mouse clicks on the media 8 Drag the Scale slider to change the size of the gaze plot fixation points Each fixation point will be scaled according to its relative size Gaze plot
206. numbers can range from O 255 with 255 being opaque and O having no opacity 4 Click in the Display settings field and type a value to change the maximum value count or duration used to map the heat map color values This setting affects the color distribution of the heat map and has a strong impact on its interpretation Read section 7 5 2 of this manual pages 92 96 before you make any changes to this setting 5 Click in the Kernel Radius field and type a value for the Kernel size width of the color mapping around a single fixation The default value is 50 pixels Read section 7 5 2 of this manual pages 92 96 before you make any changes to this setting 6 Drag the Opacity slider to change the heat map s general opacity Select the Show Clicks check box to display the participant s left mouse clicks on the media 8 Select the Show Legend check box to display the heat map legend on the image It can subsequently be moved by dragging S 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 91 and or other countries User Manual Tobii Studio 2 X Like gaze plots heat maps are dependent on the fixation filters settings Fixation filters are responsible for determining the number size and location of the fixation dots Read more about fixation filters in chapter 6 of this manual pages 76 79 7 0 2 How are
207. o This metric measures the number of visits within an AOI or AOI group Each individual visit is defined as the interval of time between the first fixation on the AOI and the next fixation outside the AOI If during the recording the participant returns to the same media element then the new fixations on the media will be included in the calculations of the metric If at the end of the recording the participant has not fixated on the AOI the Visit Count value will not be computed and the recording will not be included in the descriptive statistics calculations e g when computing N Visit Count Former Observation Count Measured in counts Fixations on media size indicates duration an e rig mS Ac 4 Eg 5 Ta a od ae 0 NZ KRY oe yr si Fh O A 8 Visit Count on AOI B in Media 1 2 9 4 13 1 N value This statistic describes the N value used to calculate other descriptive statistics such as the mean and standard deviation In the current metric it represents the number of recordings and is calculated as follows Row settings When recordings are selected as table rows the N value will always be equal to 1 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 137 and or other countries User Manual Tobii Studio 2 X If participants are selected as table rows the N value w
208. obii T Series Eye Tracker or the screen used to present the stimulus with an X Series Eye Tracker and the operator screen a secondary screen connected to the Tobii Studio computer To change the computer screen resolution settings Windows XP Open the Start menu and click Control Panel In the Control Panel click Appearance Themes and then click Display On the Settings tab under Screen resolution drag the slider and then click Apply When prompted to apply the settings click OK Your screen will turn black for a moment Once your screen resolution changes you have 15 seconds to confirm the change Click Yes to confirm the change click No or do nothing to revert to your previous setting 6 To improve the graphics card performance and reduce the hard disk load select High 16 bit for Color Quality For studies that require higher color quality use a computer with high performance and contact Tobii Support for recommendations ae SS 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 155 and or other countries User Manual Tobii Studio 2 X Windows Vista Open the Start menu on your computer and select Settings gt Control Panel 2 Double click Display and then click the Settings tab 3 Make sure that the screen resolution is set to 1024x768 or 1280x1024 for the Tobi T60 and T120 Eye Trackers and
209. of the curent freation fiter to make it active El Tobii Fixation Filter Settings Velocity Threshold 35 Distance Threshold 35 Velocity Threshold Velocity Threshold picels samples Highest velocity allowed within a fixation Velocity is measured over 5 samples Default is 35 pwels samples Click help button for details The timestamp of the fixation is taken from the first sample included in the fixation and the duration is measured from the elapsed time between the first and last sample included in the fixation The Tobii Fixation Filter is both affected by the sample rate of the eye tracker and the image resolution since h is calculated in pixels For example a 35 pixel setting will correspond to 35 16 6x5 0 42 pixels ms threshold on a 60 Hz eye tracker while on a 50 Hz eye tracker the threshold will be 35 20x5 0 35 pixels ms Due to the initial missing data interpolation if there is no significant change in the position of the gaze data points before and after 100 ms of the missing gaze data the fixation will remain intact i e one single fixation However if the consecutive missing gaze points together account for more than 100 ms 6 7 data points at 60 Hz of missing data the fixation is split into two separate fixations irrespective of its location For more details and pseudo code see the Appendix of Olsson 2007 Master Thesis P Olsson 2007 Real time and offline filters for eye tracking Msc thesis KTH Royal In
210. of the current fixation fiter to make it active After selecting the gaze data Left or Right eye or recalculating the gaze points Average you can choose either to not process the data further by selecting the Raw Data Filter check box or to process the gaze data further into fixations using the Tobii Fixation Filter or the ClearView Fixation Filter For more information on what fixation filters are and how they work see the chapter Fixation Filters chapter 6 pages 76 79 162 tobii 11 2 5 Recording settings Under the Recordings tab you can configure the recording shortcut keys The ESC key on your keyboard is the default key for ending and exiting the recording while F10 is the default key for moving the presentation to the next media element To change the recording shortcut keys 1 Click the End the recording drop down list and select a keyboard key from the list 2 Click the Move to next test element drop down list and select a keyboard key from the list 3 Click the Restore default button to restore the shortcut keys to ESC and F10 Global Settings Screen and Video Capture Eye Tracker Calibration Fixation Filters Recording Miscellaneous a 3 i Recording Shortcut keys Configure the shortcut keys for the following actions End the recording Escape v Move to next test element F10 Restore default Recording Settings for time gap between Images v Preparing
211. of the screen to show the stimulus RPE EEE j Screen and Video Capture Eye Tracker Calibration Fixation Filters Recording Miscellaneous Calibration Type Regular Manual Infant Foreground Color a pe Calibration Speed Medium Restore default Area and Points Number of calibration points 5 2points 5points 9points Background Color X Restore default Calibration Area Configure Restore default Cancel Click Restore default to reset the respective calibration settings to the default value 4 3 1 2 Manual calibration Manual calibration is best suited for studies using the Scene Camera media element or in cases where subjects have poor vision and have problems following the points in the regular calibration In these cases Manual calibration provides the ability to conduct a more accurate calibration step by step 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 49 and or other countries User Manual Tobii Studio 2 X To change the Manual calibration settings 1 Click the Foreground Color drop down list and select the color for the lines forming the calibration cross 2 Select Show manual calibration instructions to view the calibration instructions during the calibration procedure Clear the check box to hide the in
212. og box The Global Settings dialog box contains important settings that affect data recording and analysis across all Tobii Studio projects Consequently if you change the settings for one project these changes will affect the subsequent recordings and analyses in Tobii Studio even if you switch to a different project If you wish to repeat tests or analysis or simply replicate tests from a previous Tobii Studio project make sure you note the different settings used in the test The Global Settings dialog box can be opened in two different ways from the Design and Record tab click the Setup drop down menu and select Settings or click Tools on the Tobii Studio menu bar and select Settings 11 2 1 Screen and video capture settings The first tab in the Global Settings dialog box the Screen and Video Capture tab has various settings for configuring the video recordings from the screen capture and user camera the user sound and allows you to enable local and remote live viewers The halftone video scaling option determines how the video is scaled if the live viewer window size Is changed Halftoning is a technique used to make 24 bit color gradients look better on 256 color displays Halftoning normally increases the size of graphics files If the Use halftone smooth video scaling check box is selected the video will be streamed with a better image and details will be easier to see However this option requires more processor resources and c
213. olor m Ls Recording Colors T t Mi M paa sunapan rissani m Geaw Actvay Label 7 i F View Settings 106 tobii The activity data recordings name and length can be copied to the clipboard and pasted into other programs such as Excel and PowerPoint Right click the timeline under the bee swarm visualization and click Copy Activity Data to Clipboard 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 107 and or other countries User Manual Tobii Studio 2 X 8 Creating and Managing Areas of Interest The AOI definition tool enables you to define areas of interest AOI within your stimuli Instead of interpreting your data based on the direct gaze coordinates of the test participants you can base the analysis on frequency and time spent looking within the AOls AOls can be grouped together allowing for accumulation and analysis of data within and across stimuli and tests as well as more flexible and advanced test design and analysis 8 1 Creating AOls Click the AOI Tool button on the Visualization header under the Visualization tab to open the AOI tool You can create multiple AOls on any static stimuli e g images pages visited during web browsing or a static image scene representing part of an AVI or screen recording Demo Project Tobii Studio 2 1 12_ rn eles File
214. ons are only valid for tests run on a computer fulfilling the minimum requirements of the Tobii Studio system recommendations download the system recommendations document from www tobii com 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 165 and or other countries User Manual Tobii Studio 2 X 13 Tobii Studio critical timing information Tobii Studio computing operations are subject to the operating system allocation of memory and processor resources As a consequence time offsets may occur when recording an eye tracking session These offsets may vary according to the eye tracker display hardware Table 4 the type of computer used in the test laptop vs desktop processor speed RAM graphics card the video capture devices capture cards and cameras third party software installed and running on the computer and the type of stimuli and stimuli format used in the test image video codecs Table 4 Tobii Eye Trackers hardware display timing information TFT screen amp controller 1750 1280x1024 60 75 T120 amp T60 a O o T6OXL 1920x1200 These values represent typical values for a full transition of a E from TA Tests show that when using Tobii Studio with Tobii recommended hardware configurations and devices that these offsets can be maintained at a low value Tables 5a and 5b summarize the d
215. or the desired direction located to the right of the Question list Click the Edit button to modify the question slide or click the Delete button 3 to delete it Click OK to save and close the Questionnaire element setup dialog box or click Cancel to discard the changes and close the dialog box Question Setup y H o _ i J Question Setup Question Have you purchased shoes in an online shoe shop Answers Createnew Use values from existing Independent Variable Variable Name G01 Never Once Several times am a shoesholic Ofcourse have Preview E Use eye tracking on this question Close To copy and paste one or more questions from Excel to the Questionnaire element i 2 3 4 38 In Excel type the question text in the first column In the same row type the answers separated by a comma in the second column Type a name for the variable in the same row in a third column Select the three cells and copy them tobii Oa n D Ga P v 300k Viicrosoft Exc co C Ce i e Home Insert Page Layout Formulas Data Review View Add Ins Acrobat v a J j gaj rt nA a ba f i Calibri qu a Se D E Generas E H E e me ON Zi 83 2 3 Delete Paste B Z U A SEE ha gt 9 39 00 Conditional Format Cell ae Sort amp Find F Ma iF Ea z Formatting as Tabl
216. ording O All segments from all recordings in test File settings W Specify a custom filename RNHSN A4ll Data TN Test name RN Recording name SN Segment name TM Time Header gaze events and scenes Columns F Write header Available columns Selected columns E ClearView compatible inaia W Write column headers DateTimeStamp Write filter header Date Time Stamp St IW Export gaze data E Only fixations E Print AOls on separate rows W Export events gt aani V Exclude scenes Distance Left Save ted export configuration Name All data 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 71 and or other countries User Manual Tobii Studio 2 X 2 Use the check boxes on the left to quickly select the different recording data and information you want to include in the export e Select Write header to display the computer information e g system properties operating system recording information e g name date time video resolution export date and time and participant data e Ifyou also select ClearView compatible it will only display the recording date and time the test name study the participant name subject recording name screen resolution and the gaze data coordinate unit e Select Write column headers to display the
217. oup When using AOI groups the measured fixation corresponds to the first fixation on any of the AOls belonging to the group If at the end of the recording the participant has not fixated on the AOI the First Fixation Duration value will not be computed and that participant will thus not be included in the descriptive statistics calculations e g when computing N First Fixation Duration Measured in seconds Fixations on media size indicates duration i Fa A E ee A ae N E ai ps o 4 ae 9 gt p Nie all e a a f E TFF on AOI C in Media 2 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 129 and or other countries User Manual Tobii Studio 2 X 9 4 4 1 N value This statistic describes the N value used to calculate other descriptive statistics such as the mean and standard deviation In the current metric it represents the number of recordings and is calculated as follows Row settings When recordings are selected as table rows the N value will always be equal to 1 If participants are selected as table rows the N value will be equal to the number of recordings that participant has made with the same media element If participant groups are selected as rows then the N value will be equal to the number of recordings included in the group Summa
218. ox 10 1 Installing Tobii Studio Logger Tobii Studio Logger is a separate application used with Tobii Studio to remotely control and monitor a Tobii Studio recording Install Tobii Studio Logger on the computer you wish to view the remote session on The Studio Logger installation file can be found on the Tobii Studio CD or downloaded from the Tobi Updates Server http studiohelp tobii org Updates To download and install the installation file 1 Visit the website above and enter your Enterprise license key in the field and click Login 2 Click the TobiiStudioLogger download link to download the installation file 3 Once downloaded run the executable file and follow the on screen instructions Studio Logger can be installed on several computers without entering a license key Studio Logger can only connect to a Tobii Studio instance with an Enterprise license 10 2 Tobii Studio Logger computer setup The Studio Logger application and Tobii Studio are run on two different computers and communicate with the Tobii Eye Tracker Server as well as with each other over a LAN network TCP IP protocol m Computer with Tobil Studio Logger Enterprise version Tobil Studio Logger Primary Screen Stimulus Computer with Tabii ba presentation Studio Enterprise version Secondary Screen Live viewer Optional SGA out VWGOADY1 out The image from the Tobii Studio computer is displayed on the Tobii Eye Tracker sc
219. pant 1 fixates on AOI B Participant 1 fixates on AO C Participant 2 fixates on A in Media 1 1 Media 2 in Media 1 of recordings where the participant fixated at least once on the AOI Total N of recordings x 100 Percentage Fixated e g Fixated for AOI B 100 Fixated for AOI C 50 9 4 15 2 Brief description Percentage of recordings in which participants fixated at least once within an AOI or AOI group 9 4 16 Percentage Clicked This metric measures the number of recordings where participants have clicked at least once within an AOI or AOI group and expresses it as a fraction of the total number of recordings It is calculated by dividing the total number of recordings where participants have clicked within the AOI by the Total number of recordings in test 9 4 16 1 N value This statistic describes the N value used to calculate other descriptive statistics such as the mean and standard deviation In the current metric it represents the number of recordings and is calculated as follows Row settings When recordings are selected as table rows the N value will always be equal to 1 If participants are selected as table rows the N value will be equal to the number of recordings that participant has made with the same media element When participant groups are selected as rows then the N value will be equal to the number of recordings included in the group 2010 Tobii Technology All rights reserved Tobi
220. presentation of the Instruction element During the test recording an image file of the Instruction is created This is used to create heat maps gaze plots and more As a result selecting this option will make the project larger 4 1 2 2 Image An Image element is a media element that is used to present image files to the participant during a test During the presentation images are shown in actual size up to the screen s current resolution 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 23 and or other countries User Manual Tobii Studio 2 X To name the Image element 1 The software uses the image file name minus the extension once the file is added to the element You can change the element name by clicking in the Element Name field deleting the existing text and typing a new name To add an image file to an Image element 1 Click the Browse button to open Windows Explorer and browse to the image file you want to add to the test Click the image file and then select Open to add the file to the Image element A preview of the image is shown below the Image Name field Select the Show Mouse Cursor check box if you wish to display the mouse cursor on the screen during presentation of the image If the image does not take up the entire screen you can change the background color of the element
221. process will start immediately 4 When the upgrade process is completed click OK to close the Eyetracker Selector dialog box or Global Settings dialog box Firmware upgrades can improve the eye tracker s performance and set of features Upgrading the eye tracker s firmware may fix bugs resolve connection and trackability issues or improve compatibility with new operating systems 1 5 Updating Tobii Studio Tobii is committed to complying with the dynamic requirements of its clients and releases several version updates of Tobii Studio each year Customers with a valid Support amp Upgrade contract are entitled to free software updates and free technical support 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 11 and or other countries User Manual Tobii Studio 2 X To update Tobii Studio 1 Click Help on Tobii Studio menu bar 2 Select Check for Updates 3 If an update has been released it will be displayed in the Check For Update dialog box under Available updates to download 4 Download the release notes by clicking the Release notes link Release notes contain important updates and complementary information to this user manual Please read the release notes before installing the new version of Tobii Studio 5 Click the Download link and in the Download dialog box and then click Save file to start
222. r example starting the recording with the Tobii Studio computer and administering the calibration using the Studio Logger computer can cause program crashes 10 3 Connecting Studio logger Before starting a recording and adding events with Tobii Studio Logger make sure Tobii Studio Logger is set up properly and that the two applications are able to communicate with each other over the network To connect Tobii Studio and Studio Logger 1 Open Tobii Studio 2 Inthe menu bar click Tools and then select Settings to open the Global Settings dialog box Screen and Video Capture Eye Tracker Calibration Fixation Fitters Recording Miscellaneous Live viewer E Use halftone smooth video scaling you experience performance problems with this option enabled you could try to tum it off J Halftone scaling improves the video quality but decreases performance If Screen capture framerate 5 User Camera Capture E Record user camera Vice SOUITCE HP Webcam 2 MP Macro Camera Settings Video Settings Vider Microsoft Video 1 Settings E Record user sound Audio Source V Enable live viewing V Enable remote viewing Use multicast Multicast IP address 225 1 1 111 Multicast is disabled by default f you want to transfer the screen v capture to more than one computer on the network this option should be tumed on Broadcast V Sound V Camera image 3 On the Screen and Video
223. rder Width field or click the arrows in the box to change the value 7 Select the Show Name Labels check box to display the AOI label To change the label font click Change Font and select the font properties in the Font dialog box When the new AOI is added to the image the name color and AOI area coverage information will be added to the Areas of Interest list towards the lower part of the Selection pane You can use the check boxes in front of each entry in the list to enable or disable the AOI on the stimuli Each entry on the list displays the color of the AOI the size of the AOI area as a percentage AOI area total image area and a settings button TE 8 2 Editing AOls After an AOI has been created you can edit its shape area position and appearance AOls can also be copied to different media in the same test or between different tests To edit an AOI 1 Click the Select cursor on the Tools menu in the lower area of the Visualization pane Click the AOI you wish to edit and the anchor points are displayed Alternatively you can click the desired AOI row in the Areas of Interest list 2 Drag the anchor points to change or adjust the shape o Project Tobii Studio 2 1 12 File View Tools ForSight Help Design and Record Replay Visualization Statistics E Bis fe D Print Advertisements Export AOI Groups Gaze Plot HeatMap Cluster Bee Swarm P Diapers 01 jpg Diapers 02 jpg F fixationcross jpg F
224. re Clear the check box to hide the instructions 4 Set Number of calibration points to 2 5 and 9 points 5 Click the Background Color drop down list and select the color for the calibration background screen 6 Click Configure to adjust the area of the screen that will be used when performing calibrations This may provide a more accurate calibration if you are planning to use a small area of the screen to show the stimulus Click Restore default to reset the respective calibration settings to the default value E Screen and Video Capture Eye Tracker Calibration Fixation Filters Recording Miscellaneous Calibration Type Regular Manual Infant Calibration Animation C Program Data Tobii Studio InfantCalibration 6 avi Attention Animation Z Show infant calibration instructions Area and Points Number of calibration points 2points 5points Ypoints Background Color x Restore default Calibration Area Configure Restore default Some sample movies are included in the installation and can normally be found in the Infant Calibration AVIs folder C ProgramData Tobii Studio InfantCalibration Infant calibration is an interactive calibration mode where an operator uses the keyboard to control the calibration procedure 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in
225. reen and the Tobii Studio computer therefore needs to be connected to the display of the Tobii Eye Tracker The computer running Studio Logger displays the Studio Logger window that broadcasts the image from the Tobi Studio computer via the LAN connection The two computers therefore have to be connected to the same network A secondary screen can be added to the setup to enable the eye tracker operator to monitor the progress of the test during the stimulus presentation and recording To make your study more portable replace the computer in the setup drawing with a laptop or shuttle computer Things to remember when setting up the two computers for remote viewing and logging 1 Studio Logger can only be used on a local network Ideally a dedicated network should be used solely for the Tobii Studio computer and the Studio Logger computer 150 tobii The network bandwidth must be high Studio Logger requires at least 30 Mbps in order to work smoothly The network must be stable A disconnection of either the Tobii Studio computer or the Studio Logger computer might result in difficulties reconnecting during an active recording session Should this occur you must close and restart both applications The same version of Tobii Studio and Studio Logger must be installed on both computers To avoid problems use either the Tobii Studio computer or the Remote Logger computer to control the recording NOT BOTH during the same session Fo
226. resents the number of recordings and follows the rules described in the previous paragraph row settings In the AOI metric summary columns the N value represents the number of recordings x the total number of AOls i e all AOls included in all media elements 142 tobii Time to First Mouse Click Measured in seconds LAOI A d Mouse click on media S oh hh 9 4 19 2 Brief description The time from the start of the media display until the test participant left clicks with the mouse on the AOI or AOI group for the first time seconds 9 4 20 Time to First Mouse Click Across media seconds This metric measures how long it takes before a test participant left clicks with the mouse on an AOI or AOI group for the first time The time measurement starts when the media containing the AOI is first displayed and stops when the participant clicks on the AOI When using AOI groups the time measurement stops when the participant clicks on any of the AOls belonging to the group If during the recording the participant views the same media several times the Time to First Mouse Click value will be calculated from the first time the media was displayed until he she clicks on the AOI recording time without excluding the view times of other media If at the end of the recording the participant has not clicked on the AOI the Time to First Mouse Click value will not be computed and that recording will thus not be included in the descript
227. riptive statistics is based on the number of recordings see the N value description below for more details A visit is defined as the interval of time between the first fixation on the AOI and the next fixation outside the AOI If during the recording the participant returns to the same media element then the new fixations on the media will be included in the calculations of the metric If at the end of the recording the participant has not fixated on the AOI the Total Visit Duration value will not be computed and the recording will not be included in the descriptive statistics calculations e g when computing N 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 135 and or other countries User Manual Tobii Studio 2 X Total Visit Duration Former Observation Length Measured in seconds Fixations on media size indicates duration Qoc00p0 Q00 WOO Media 1 view time Media 1 view time e Ist visit to AOI B duration of the 2nd visit to AOI B number of recordings mean Total Visit Duration on AOI B in Media 1 9 4 11 1 N value This statistic describes the N value used to calculate other descriptive statistics such as the mean and standard deviation In the current metric it represents the number of recordings and is calculated as follows Row settings When recordings are selected as table rows
228. rom the Video Codec list The choice of codec will impact the video quality file size and CPU load during recording For most purposes the Microsoft Video 1 is recommended 4 Click the Settings button to set the temporal quality ratio of the video compression The higher the quality ratio the more detailed the recording will be However the recording will also consume more CPU resources 5 Click Edit to select which codecs are enabled These codecs are then shown in the Video Codec list 6 Click the Preview box to preview the image streamed from the device B Scene Camera Setup This element records everything that is received from an extemal video source until it is manually stopped It allows perspective mapping of gaze data Element Name Camera Capture Perspective Calibration Video Source Calibration Image Logitech QuickCam Chat Camera Settings Video Settings Video Codec Click to preview Microsoft Video 1 Settings Edit New To set device specific settings 1 If your external device is a video camera click Camera Settings to change the video image settings such as brightness and contrast 2 Click Video Settings to change other device specific hardware settings such as video size and frame rate Notes In most cases when making a video recording the video signal needs to be converted from analog to digital This is done by using codecs B
229. rrectly positioned in front of the eye tracker 12 Click Start Recording to show the test and record media and eye tracking data 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 153 and or other countries User Manual Tobii Studio 2 X 13 The recording can be stopped and the media display controlled by clicking Next Stop in the Remote Desktop pane To log events 1 During the recording press the keyboard key defined in the Coding Scheme logging scheme in Tobii Studio or click the event in the Log Category list in Tobii Studio Logger to log an event 2 Add a comment in the Log Message window that opens when logging events This message will not appear if quick logging is selected in the Coding Scheme dialog box read more about how to define events in section 5 3 of this manual pages 61 64 3 Once the recordings are finished go to the Replay tab in Tobii Studio to view the added events The events are listed in the Events list and added as bookmarks on the timeline 154 tobii 11 General Settings Prior to a test session it is important to ensure that both the Tobii Studio software and the computer have been set up correctly This ensures that the eye tracker will be able to communicate with Tobii Studio that the stimulus is correctly displayed on the screen and that data recording and analysis are p
230. rval 2 Drag the right marker to set the start of the data interval To set the interval using the Start and Length fields more precise 1 Click in the Start field below the visualization and type the hh mm ss ms values to set the start of the interval Alternatively you can use the arrows in the field to increase or decrease the time values The time format is hours minutes seconds miliseconds 2 Set the length of the interval by clicking in the Length field and typing the hh mm ss ms values As in the Start field you can use the arrows in the field to increase or decrease the time values Note By selecting a smaller time window some recordings might be excluded from the visualization altogether 7 4 Creating gaze plots The Gaze Plot visualization shows the sequence and position of fixations dots on a static media e g an image or a scene The size of the dots indicates the fixation duration and the numbers in the dots represent the order of the fixations Gaze Plots can be used to illustrate the gaze pattern of a single test participant throughout the entire eye tracking session or of several participants in a short time interval iol Tce S eT a Dean and Hiecord Plenary Viraali rron mo Oq D Map Cisie Bee Swarm ADITosl Dewrload ig Derwrdese Spobly fer Ariat y Premium Swak ia Producn gyevi Sporty pay Avada of mumie inate w You bre Bayard perman You are buying Spobly premium Web Groups F
231. ry columns In the AOI media summary columns the N value represents the number of recordings x the number of AOls included in a single media element In the AOI group summary columns the N value represents the number of recordings and follows the rules described in the previous paragraph row settings In the AOI metric summary columns the N value represents the number of recordings x the total number of AOls i e all AOls included in all media elements 9 4 4 2 Brief description Duration of the first fixation on an AOI or an AOI group seconds 9 4 5 Fixation Duration seconds This metric was previously called Fixation Length in older versions of Tobii Studio and measures the duration of each individual fixation within an AOI or within all AOls belonging to an AOI group The N value used to calculate the descriptive statistics such as mean and standard deviation is based on the number of fixations see the N value description below for more details If during the recording the participant returns to the same media element the new fixations on the media will also be included in the calculations of the metric If at the end of the recording the participant has not fixated on the AOI the Fixation Duration value will not be computed and that recording will thus not be included in the descriptive statistics calculations e g when computing averages for participant groups 9 4 5 1 N value This statistic describes the N value u
232. s 1 2 n 3 n 1 4 n 2 5 n 3 1 N I where the sequence 1 n n 1 n 2 n 3 n i alternates with the sequence 2 3 4 5 For example with n 4 media elements the first sequence of the Latin Square is Recording 1 1 2 4 3 each number represents a media element Since the number of media elements is even n 4 then the number of sequences needed is equal to x 4 The remaining sequences are obtained by adding 1 to each value in the previous sequence In this example if the value is 4 in the first sequence the next sequence will have the value of 1 In this example we thus obtain the following sequences Recording 1 Recording 2 Recording 3 Recording 4 We see that in this Latin Square media element 1 follows immediately after media elements 2 3 and 4 one time each Similarly media element 2 immediately follows media elements 1 3 and 4 one time each media element 3 immediately follows media elements 1 2 and 4 one time each and media element 4 immediately follows media elements 1 2 and 3 one time each 42 tobii If the number of media elements is odd we need to create twice as many sequences as media elements x 2n We first start by following the same equation as when the number of media elements is even and go through the n sequences When this is done we reverse the first set of sequences to create a second set For example when 5 media elements are randomized the first sequence of the first
233. s are dependent on the fixation filters settings Fixation filters are responsible for determining the size and location of the fixation dots read more about fixation filters in chapter 6 of this manual pages 76 79 7 5 Creating heat maps Heat maps can be of great value when creating reports papers or presentations as they help you to summarize large quantities of data in an intuitive way A heat map uses different colors to show the number of fixations participants made in certain areas of the image or for how long they fixated within that area Red usually indicates the highest number of fixations or the longest time and green the least with varying levels in between In spite of its intuitiveness the task of interpreting a heat map is more complex than it seems For a critical discussion on how to interpret heat maps please read Bojko s 2009 paper entitled nformative or Misleading Heatmaps Deconstructed Bojko A 2009 Informative or Misleading Heatmaps Deconstructed in Human Computer Interaction Part I HCIl 2009 Jacko J A Ed Springer Verlag Berlin pp 30 39 Download Help Blog Media Spotify A world of music Instant simple and free Participant filter All 23 counts About Account Work with us Legal Ha English v lt Snotify Overviev Privacy polic 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology
234. s setting so that a window that has been lost on the secondary screen can be recovered Pressing this button will reset the position of the user cam and track status window as well Forget live viewer window position By default the live viewer and track status window will be displayed at the last location secondary or primary screen where they were active If their previous location was on a secondary screen which is no longer connected they will not be shown on the primary screen By clicking Forget live viewer window position they will be shown on the primary screen again 164 tobii 12 Tobii Studio media limitations Below is a list of the maximum number of media files the amount of recordings and the duration of media presentation that can be used in a test Tobii Studio 2 1 13 1280 x 1024 pixels screen image resolution e 200 images each image presented for 5 seconds gt maximum 120 recordings e 4 images each image presented for 5 seconds gt maximum 1200 recordings e PDF 200 MB 20 minutes recording gt 100 recordings e 40 movies that are 20 seconds long gt maximum 40 recordings e 4 movies 20 seconds long gt maximum 250 recordings 1920 x 1200 pixels screen image resolution e 200 images each image presented for 5 seconds gt maximum 120 recordings e 4 images each image presented for 5 seconds gt maximum 1200 recordings e PDF 200 MB 20 minutes recording gt 100 recordings Note The limitati
235. s table rows the N value will be equal to the number of recordings that participant has made with the same media element If participant groups are selected as rows then the N value will be equal to the number of recordings included in the group Summary columns In the AOI media summary columns the N value represents the number of recordings x the number of AOls included in a single media element In the AOI group summary columns the N value represents the number of recordings and follows the rules described in the previous paragraph row settings In the AOI metric summary columns the N value represents the number of recordings x the total number of AOls i e all AOls included in all media elements Time to First Fixation TFF Measured in seconds Se 4 4 4 14 o mae 2 lt AOI B 15 ke PAOLA eur Fixations on media size indicates duration d e AN a a ai F N EON PeT g n gt gt ai F aii e SE i Gy AA 7 8 P 10 11 J 3 14 15 C i G TFF on AOI C in Media 2 E OAA In Mea TFF on AOI A in Media 1 9 4 2 2 Brief description The time from the start of the media display until the test participant fixates on the AOI or AOI group for the first time seconds 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 127
236. s the Subnet Mask In the Logger Setup menu you can also Select Show Track Status in a pop up window Select Hide Main Application if you wish to minimize Tobii Studio on the eye tracker screen during the test Select Gaze overlay settings to open the Overlay settings dialog box Clear the Draw Gaze data check box to hide the gaze overlay during remote viewing Drag the Opacity slider to change the opacity of the gaze overlay Click the Overlay color box to choose the color of the gaze overlay Select Smooth Scaling to display a less pixilated video image Select Full Screen to display the Remote Desktop image in Full Screen during the recording To exit the full screen press F11 10 4 Controlling the recording and remotely logging events Before events can be logged with Studio Logger the events and respective log keys have to be defined in Tobii Studio using the Coding Scheme feature read more about how to define events in section 5 3 of this manual pages 61 64 To start a Tobii Studio recording from Studio Logger 1 First verify that the user camera and user sound settings are correct see the previous section to learn how to set the user camera and user sound settings 2 Start Live Viewer in Studio Logger Click the Live Viewer button in the Remote Desktop pane 3 Verify that the participant is properly seated in front of the eye tracker Click the Setup button and select Show Track Status The Track Status window opens T
237. sassaeduroieebainecuexavecacthadbisemiaerineeioisaasaueieeenteeioienmstauaeinateres 44 4 2 2 Creating independent variables sesssesesseessseessssseseesesecseeeeeesecasneseeaeeecaeseeaeseeeseseseeeeaesesienseeneens 46 4 3 Calibrating and recording participants ceccceesesceeseeeseeeessseceeseteesesecaesecaseeesseseeaseesaesasaesesaeeesateesatienenaeas 47 ro a CAGO SST ge see eee eee a eee eee en ee ee eee ee ee eee eee 48 A2 Nakd Migs 1819 Lea eee een eer eer er eee ee ee eee eee eae eee eee rer 52 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 1 and or other countries User Manual Tobii Studio 2 X 5 Replaying and Editing RECOrdINGGS cssssssssssssessssesesssssseesesessenesesseaeseseseenesesseaeeseseenesesenaeaeseseeneeseneeaeseseeneneseners 56 5 1 Paypak Sonig Kop eperer eye ene en rn rer a perro ee er rere ere rer 57 Sill Customizing the recordings St isto aaae aaa Sa aE des secanstantecdadateenieeaneseausotac eens 57 5 1 2 Changing the timeline scale detail and playback speed ss sssesssssersrsrssssrsrersnsnesrennrnsnnnrennnnnsnnnnenenns 57 5 1 3 Customizing the view of the Replay tab s s ssssssssssssessrsnsnsnssrsrenensnnnnsnennnsnnnnnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnne nna 58 5 2 Performing a Retrospective Think Aloud reCOrding eccecesseceeseeeeeeeeeeeecaeeeeseeaseeesesaseesseeatses
238. sed to calculate other descriptive statistics such as the mean and standard deviation In the current metric it represents the number of fixations and is calculated as follows Row settings When recordings are selected as table rows N is equal to the total number of fixations on an AOI If participants are selected as table rows N is equal to the total number of fixations a participant has made on the AOI If the participant has made more than 1 recording with the same media element N will be equal to the sum of the number of fixations from all the recordings If participant groups are selected as rows then N will be equal to the sum of the number of fixations of all the recordings included in the group 130 gA tobii Summary columns In the AOI media summary column the N value represents the total number of fixations on all AOls included in a single media element In the AOI group summary column the N value represents the sum of the fixations on all the AOls belonging to the same AOI group and follows the rules described in the previous paragraph for recordings participants and participant groups In the AOI metric summary column the N value represents the total number of fixations on all AOls included in all media elements Fixation Duration Measured in seconds i A N Si Al 4 Sa LAO A J Fixations on media size indicates duration Ta N A N sh as atoi 2 PRN FR TA
239. seesaseeeaseesesneneeienenieenens 147 9 6 Table and char exponera a rere recite S fe ecret rr ae ore eon ener reer ee 147 10 MOD SULIGIO LOGG creana a S 149 101 Installing Tobit Studio Logger iiion a a a Na 150 10 2 Tobii Studio Logger computer setup s s sessssssrsrsrssrrssrsrenrnsnsnisntntntntntnnnntnnnnnnnnnnnnnnnnnnnnnnnnnnn annene nenene nennen 150 193 Co mecuing Studio loggel s nsemi aa nana eaters esata eee 151 10 4 Controlling the recording and remotely logging CVENHS ccccecesseeeteeeteteetsteeastetesteeetetetseeetaeeeeaeas 153 11 e E ae e AE E A E E E E A EEE E E S E EEE 155 tl Computer setihgssicsseopa a a a 155 11 1 1 Setting up display resol t Minion a A a e 155 11 1 2 Configuring a dual screen computer SETUP eesesesesseeceeeeeeeeeseeecseeesseeeeaeseesssesesseeeseeeeteneteens 156 11 2 TobilSt dio Global Settings dialog DOX nivszssniia a a 158 11 2 1 Screen and video capture Settings ecsescecssecesseeeseseeeseeseseeecsesecseseceeseeseseeessetesaesesasseeeetenenietan 158 11 2 2 Eye Tracker browser and hardware settings csscceceseeeeeeeeeeeeeeeeeeeeaeeeeseeaesaeeessetaseeeaeeateesaeeataes 160 11 2 3 Calibralon Seting Serrone E EEE A E E EE 161 11 2 4 Fanon mier SO UUING S eeen E 162 11 2 5 RecordiNg Seting Seater ranor E E neat el tava seseeeedes 163 11 2 6 Miscellaneous SC LLIN G S yreur E E 164 12 ToDii Studi media limitation Siea aeneae ERa A aaa ai aaan EAEE a ANE 165 13 Tobii Studio critical timing i
240. set is equal to 1 2 5 3 4 and the first sequence of the second set is equal to 4 3 5 2 1 where each number represents a media element Recording 1 Recording 6 Recording 2 Recording 7 Recording 3 Recording 8 Recording 4 Recording 9 21354 Recording 5 51423 Recording 10 32415 The reason for doubling is that we need to make sure that each media element is followed by each of the other media elements the same number of times to counterbalance for order effects In the first set media element 2 is followed by 3 twice and by 5 twice but isn t followed by 1 or 4 at all Therefore the second set is created and 2 is followed by 1 twice and by 4 twice 4 1 5 Unlocking Tobii Studio Tests for editing After you have performed a recording the test will become locked This is to prevent any accidental modifications during the test sessions If you want to modify the test you first need to unlock it To unlock the test 1 Click the lock icon located in the upper right part of the media element toolbar 2 Click Yes in the confirmation dialog box to confirm the procedure 4 1 6 Test preview The Preview Test feature allows you to preview the media elements on the timeline as if it was a real test but without creating a recording This way you can verify that the media elements are setup correctly with the right content and settings and that the transitions between the different elements are as desired To preview a test 1
241. set up different media elements see section 4 1 2 of this manual pages 22 41 3 Click OK to accept the settings and close the dialog box 4 The media is now visible as a slide icon in the center of the test workspace The line behind the media element represents the timeline and the arrow represents the direction of the test Right above the media element is the position number of that element in the current test 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 21 and or other countries User Manual Tobii Studio 2 X 4 1 2 Media element types Tobii Studio integrates different types of media for analysis The different media elements can also be referred to as stimuli Media element types stimuli Instruction Text elements that can be used to display instructions or describe tasks to the participant m Image Presents picture or graphic elements i e BMP GIF JPG JPEG TIF TIFF PNG Movie Presents video in AVI or ASF format only formats accepted Web Websites added by entering the URL or web address of the website viewed in Windows Internet Explorer browser l Screen Rec Used to record stimuli that are presented by an external software application or the software itself and shown on the local screen E External Video Records the video output of software games or a program running on an e
242. sional Enterprise Instruction stimuli o Image stimuli Movie stimuli e Web stimull PDF stimuli e Questionnaire stimuli e Scene camera External video 8 Independent variables Stimuli related events Keystrokes and mouse clicks Web page transitions and scrolling Internet Explorer Event Logging e User video and sound e Local live viewer Remote live viewer over IP Retrospective Think Aloud RTA Replay Gaze replay Video clips e Gaze plot Heat map Areas of Interest AOls e Automatic cluster AOls Beeswarm Statistics Descriptive statistics tables and charts Data Filters Fixation filters e Raw data visualization amp export unfiltered gaze data Tobii Studio Non Recording Version A Non Recording version of Tobii Studio is also available for purchase This version allows you to import replay edit and analyze projects recorded with a full version of Tobii Studio The replay and analysis features available in the Non Recording rversion of Tobi Studio are tied to the features of the Tobii Studio edition Basic Professional or Enterprise used to perform the recordings If you wish to have more information on the Tobi Studio Non Recording version contact your sales representative Contents 1 Installing and Updating Tobii Studio wu essssssssssssssssessssssssesssseseseassseseseseseeneeeaeoeaesessnseseaearaeaesesesneneaeaeaeaeseen
243. site in Internet Explorer and automatically records all mouse clicks key strokes and websites visited during the test Currently Internet Explorer is the only browser supported by Tobii Studio s Web element To name the Web element 1 The software uses Web Element as the default name You can change it by clicking in the Element Name field deleting the existing text and typing a new name To add a start URL and change the browser settings 1 Click the Start URL field and type a URL or a local computer address you do not need to type http 2 Select whether you want to launch the browser using a fixed browser size or in full screen mode Skip steps 3 and 4 if you select Fullscreen 3 Set the browser s starting location by typing values in pixels The top left point of the screen has the coordinates 0 0 and the browser s origin is the top left point of the window For example by typing Left O and Top 0O the top left corner of the browser is in the top left corner of the screen 4 Type the width and height of the browser window in pixels 28 we This element opens a web browser and lets the participant navigate from a predefined web page You need to specify a stat URL Bement Name Web Element Browser Settings Start URL Fixed browser size Let 0 ll Top D Width 1280 la Height 1024 E Fullscreen Properties End recording with F10 or Escape E End recording after 20 LA seconds 0 3 min
244. slower or faster pace The playback speed bar is in the lower left corner of the Replay pane The speed is represented by the silhouettes of a hare and a tortoise for fast and slow Change the playback speed by dragging the marker on the speed bar towards the hare to increase the speed or towards the tortoise to decrease the speed The middle line represents the original recording speed 5 1 3 Customizing the view of the Replay tab To provide a greater flexibility of analysis the various panes and toolbars in the Replay view Recordings Events User Cam Segments Scenes and Settings can all be resized or hidden displayed This allows you to customize the window so you have easy access to the functions you use most You can choose to hide the Recordings pane by clicking the Left Arrow button in the lower right corner of the Recordings pane or if hidden display it by clicking the Right Arrow button in the lower left corner of the Tobii Studio window You can also toggle between displaying and hiding the Events and User Cam panes by clicking their respective icons at the bottom of the Recordings pane The same goes for Segments Scenes and Settings which have icons in the lower left corner of the Replay pane You can resize any of the panes by dragging its border in the desired direction The recording of a test session can be viewed in fullscreen mode Fullscreen mode replay shows the recorded media in its original size making it more easily
245. st f you are running a Tetserver locally Host Name Optional Add eyetracker ce The first element in the Eye Tracker tab is a list of eye trackers that are connected either to the Tobii Studio computer or to the network the computer is connected to The list displays information on whether the connection to the eye tracker was made automatically or manually Type the address used to connect with the eye tracker Host the name Name and serial number Serial of the eye tracker and the type of eye tracker Model 160 tobii To select an eye tracker click the row in the list that corresponds to the eye tracker and then click the Test selected eye tracker button A message showing the status of the connection is displayed If you are unable to see your eye tracker in the list click Can t find your eye tracker to restart the protocol used to communicate with the eye trackers Bonjour If you are still unable to connect to the eye tracker see the troubleshooting section of the eye tracker user manual or contact Tobii Support The Delete selected eye tracker button is used to remove eye trackers that have been manually added to the list If you are using a Tobii X Series Eye Tracker click the X Series Config Tool button to open the X Series Configuration Tool dialog box and set up the X Series Eye Tracker the button is only available if you select a Tobii X Series Eye Tracker Earlier eye tracker models e g 1750 a
246. still images have to be defined before a gaze plot can be drawn This is done by creating scenes read about how to create scenes in section 5 5 of this manual pages 67 69 7 4 1 Customizing gaze plots You can change the appearance of the gaze plot to customize your image or to give emphasis to a specific part of the information displayed on the fixation dots Most of these changes can be made in the Settings menu which can be accessed by clicking the Settings button in the lower left corner of the visualization pane To change the color of the gaze plot for a recording 1 Inthe Recordings list double click the color icon next to the recording to open the color palette dialog box 2 Select the color and click OK to accept the change ian bons aes File Wew Took Fersght Help t Em a fo Print Advertisements bpon AO Groups Web Groups Gare Hootie iusi Bee Sevarm 401 Tool E Diepers 01 jeg IE Dapet pg E footie jpg E Jute jd Bie jue ey ale Hewapaper Bisel sez White jpg Newspaper Coloring See SS a E Traveli pig E z z a piima Teel 02 jpg eo OO ee e S Fier bor Wo Gaoun Selected a re Lammr ese COR Mere Samp Perse HO ive sol teachers EE rect mek Ores Egs re2 Oa O Q ret Er Lact 5 ii Dre 95 I wets opto eticr work aie 7 Eee Scent Areas ol Intorost To change other appearance settings of the fixation dots Click the Setti
247. stitute of Technology April 2007 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 79 and or other countries User Manual Tobii Studio 2 X 7 Visualizing Eye Tracking Data Being able to visualize your data in a number of ways with gaze superimposed on any kind of stimulus enables you to make a visual qualitative inspection of your results Visualizations are easily exported by right clicking and selecting copy or saving as an image Several recording sessions from multiple test participants can be summarized in a single gaze data visualization helping to draw conclusions and new hypotheses from the behavior of a group of participants Effective tools for multi person analysis with an option to further filter the participants of a group into categories provide a time and cost efficient way to collect such data Visualizations also help to illustrate and communicate your results in research papers reports and customer or conference presentations Some visualizations are only available if you have purchased a specific Tobil Studio version See the preface of this manual to see which visualizations are included in your Tobii Studio license If a tool is not activated the button will be gray If you wish to activate a visualization tool you will need to upgrade to a license of Tobii Studio that includes the tool
248. structions 3 Set Number of calibration points to 2 5 and 9 points 4 Click the Background Color list and select the color for the calibration background screen 6 Click Configure to adjust the area of the screen that will be used when performing calibrations This may provide a more accurate calibration if you are planning to use a small area of the screen to show the stimulus Click Restore default to reset the respective calibration settings to the default value Screen and Video Capture Eye Tracker Calibration Fixation Fiters Recording Miscellaneous Calibration Type D Regular Manual Infant Foreground Color z pe V Show manual calibration instructions Restore default Area and Points Number of calibration points Background Color Calibration Area 2points 5points Restore default Configure Restore default Spoints Manual calibration is an operator paced calibration procedure with special graphics during the calibration procedure The number of calibration points and their locations are by default the same as for Regular calibration but instead of a pulsating dot two lines create an intersection that is used as the calibration point When the space bar is pressed the lines change color while calibration is performed and the lines move to the next calibration point When the participant has looked at all points the calibration results wil
249. t our clients knowledge levels and needs and cover everything from how to use our products to basic understanding of eye tracking methodology For more details on the available courses visit the Products amp Services section at www tobil com or contact the Tobii sales representative in your area Alternatively you can also send an e mail to training analysis tobii com Technical Support Tobii Technology Technical Support services are available to customers with a valid support and upgrade contract Customers may contact Tobii Technical Support for assistance in installing and using Tobii Studio and Tobii Eye Trackers and to obtain information on recommended and supported hardware and OS environments To reach Technical Support use the following contact phone numbers and e mail addresses Germany and Eastern Europe Languages German and English Phone 49 69 24 75 03 427 Email support tobil com North America and Mexico Language English Phone 1 703 738 1320 Email support us tobiil com Japan Language Japanese Phone 81 3 5793 3316 Email support jo tobil com Sweden amp Rest of the World Languages Swedish English German French and Spanish Phone 46 8 6636003 Email support tobil com Tobii Studio Editions Tobii Studio is available in three editions Basic Professional and Enterprise The table below shows the features available in each of the Tobii Studio editions Features Basic Profes
250. ta and 7 32 and 64 bit versions 1 1 1 nstall Microsoft NET and DirectX Microsoft NET framework 3 5 SP1 must be installed on the computer If it is not installed install from the folder on the installation CD or from the Support amp Downloads section at www tobii com DirectX version 9 or higher must be installed on the target computer It is installed with the operating system Windows XP or Vista To check the DirectX version on your computer 1 Click the Start menu 2 Type dxdiag in the search field Windows Vista or in the run field Windows XP and click ENTER 3 The current DirectX version can be found under the System tab in the DirectX Diagnostic Tool dialog box If Direct X version 9 or higher is not installed download it from the Microsoft Download center http www microsoft com Downloads Search aspx If you are using Windows XP you need to install DirectX 9 If you are using Windows Vista install DirectX 10 1 1 2 Install the driver for the eye tracker built in user camera Additionally if the eye tracker has a built in user camera Tobii T Series Eye Trackers and its serial number is equal to or lower than TTXXX 204 XXXXXXXX you need to manually install the user camera driver This driver is not compatible with Windows 64 bit versions To manually install the driver in Windows Vista Insert the Tobii Studio CD close any autoplay window On the Windows taskbar click the Start button Locate and op
251. ta from both eyes and thus select the average 4 Select the type of filter you want to use Choose between Tobii fixation filter ClearView Fixation filter and Raw Data If you select Raw Data Tobii Studio will display all the eye position samples recorded by the eye tracker without aggregating it into fixations 5 If desired change the selected filter s settings see sections 6 1 and 6 2 of this manual for a more in depth view of the filters pages 77 79 6 Click OK to accept the changes and close the Global Settings dialog box As previously mentioned the fixation filter affects how gaze plots heat maps clusters and eye tracking metrics are calculated Choosing a fixation filter does not modify the raw gaze data recorded by Tobii Studio and you can therefore change the filter settings without affecting the original data recorded 6 1 ClearView Fixation Filter The ClearView fixation algorithm is based on the I VT Velocity Threshold Identification fixation filter outlined by Salvucci and Goldberg 2000 The velocity feature is calculated by measuring the distance between two adjacent data points Each point is then labeled as a fixation if the velocity is below a certain threshold or otherwise as a saccade The threshold is set by selecting a Velocity Threshold value i e this value represents the maximum pixel distance between two consecutive data points for them to be considered part of a fixation Every point that is located above t
252. tart and stop times of the media presentation and the media description AOI data Exports fixation and AOI data The export includes the timestamp of when the fixations were initiated fixation duration AOI ID reference number AOI name and the media name stimulus Fixation data Exports the fixation data together with the timestamp of when the fixations were initiated The export includes fixation duration data the mapped screen X and Y positions of the fixation and the fixation index or order This export is the same as the ClearView fixation data export Combined data This export is the same as ClearView s combined data export It contains gaze data events fixation and AOI data together with media information To create an Advanced export 1 Select the Specify a custom filename check box to use your own file name format for your data exports You can include the following tags to include the tag information automatically in the export file name Folder settings TN Name of the current test RN Replaced with the name of the current recording SN Replaced with the name of the current segment If the current element is not a segment this part will be excluded from the file name TM Time when the export file was created Output folder C Users wms Desktop Export scope Create sub folders E Project F Test f Recording Curent recording 5 All recordings in test Segments in curent rec
253. ted bo 00 T0 6T hti pwn URLStart 9 oyaltours i_ KeyPress ae 13 70 E40 00 00 19 786 ven Anp za URLEnd oyaltours i ScreenRec 00 00 20 002 St opad 2 me uctionS a 00 20 45 Task 2 Travel offe BerochonE 60 00 29 3 Task 2 Travel ofe gaara ai banat URLStart a Sen bo 00 51 46 h fiip TANN T URLEnd 0 altours i 00 00 51 89 hit vise Pose RS Time ne 7 gt a b Text Juice 01 jpg i ee a E lt Events User Cam Segments Scenes Settings Recording Rec 1 length 00 01 36 818 participant test 7 Click Start Recording to start the RTA session Above the Replay header a light gray tab indicates that the RTA recording mode is active The duration of the recording is shown at the upper right W Scientific Project Tobit Studio 0 21 194 2010 02 25 09 24 59 changelist 44904 Recording lems File View Tools ForSight Help Retrospective Think Aloud 0 min 3 sec Stop RTA Design and Record Replay Visualization Statistics f T a S 9 ReadingandFaces Generate Export RTA Help Name Date v Samples 7 26 2009 3 F o Rec 09 1 08 25 PM 94 Rec 02 seus 95 3 12 54 01 PM D i 2009 or o E Rec 04 1 22 4PM 94 i ay Rec 03 1411 PM 97 one H m R Rec 43 10 40 33am 92 I O Rec 41 he gii 3 60 tobii 8 During RTA recording you can use the playback controls to move through the original recording Use other fe
254. ted web URL and PDF page will become a unique media element If the Web Groups tool is used to group two or more URLs the group and not the URL will become a unique media element Time from First Fixation to Next Mouse Click Measured in seconds om A i h h CID Fixations on media size indicates duration tk ies 1 000000 8 J ait mes Time from First Fixation to Next Mouse Click on AOI B in Media 1 9 4 271 1 N value This statistic describes the N value used to calculate other descriptive statistics such as the mean and standard deviation In the current metric it represents the number of recordings and is calculated as follows Row settings When recordings are selected as table rows the N value will always be equal to 1 If participants are selected as table rows the N value will be equal to the number of recordings that participant has made with the same media element When participant groups are selected as rows then the N value will be equal to the number of recordings included in the group 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 145 and or other countries User Manual Tobii Studio 2 X Summary columns In the AOI media summary columns the N value represents the number of recordings x the number of AOls included in a single media element In the
255. ternal device Tobii Studio records the video input from these devices as a video file along with gaze data keystrokes and mouse clicks This media element cannot be combined with other elements in the timeline This media element type is recommended for presenting stimuli that have complex graphics or are resource intensive applications such as video games interactive television and computer games played on another computer The recordings are made via e Analog video capture cards for VCR input e VGA or DVI capture cards for input from another computer e VGA to USB converter to capture VGA signal from another computer via USB should be used only with low resource graphics applications e FireWire T X series for digital cameras e USB streaming from video or web cameras Before adding the External Video element to a test make sure the hardware is set up properly The video source needs to be connected with a video capture card FireWire cable or USB cable to the computer where Tobii Studio is running Install the correct drivers and codecs on the computer to avoid possibly compromising recording performance Please refer to the system recommendations document available at www tobii com or contact Tobii support for information on recommended video capture cards and setups To name the External Video element 1 The software uses External Video Element as the default name You can change it by clicking the Element Name fi
256. text export configuration field and click Save to save the configuration to the Present Configurations tab 5 6 2 1 Event data The table below shows the Events and the Event Data that can be found in the text export and the Events list on the Replay tab Image Name Movie Name URL website name X mouse coordinate Log name 72 tobii 5 6 2 2 Text export columns The list below shows all the data that can be exported using the Tobii Studio Text export The first part of the list contains the data that is processed in the eye tracker and sent to Tobii Studio and the second part of the list shows the data that is further processed in Tobii Studio Eye tracker gaze data e Timestamp Shows the timestamp in milliseconds of when the gaze data was collected e Gaze PointXLeft Horizontal screen position of the gaze point for the left eye 0 is the left edge the maximum value of the horizontal screen resolution is the right edge e GazePointYLeft Vertical screen position of the gaze point for the left eye 0 is the bottom edge the maximum value of the vertical screen resolution is the right edge e CamXLeft Horizontal location of the left pupil in the camera image 0 is the left edge 1 is the right edge e CamYLetft Vertical location of the left pupil in the camera image 0 is the top edge 1 is the bottom edge e DistanceLeft Distance from the eye tracker to the left eye The distance is given in mm ona straig
257. their relative position 6 The eye tracker screen should be set as the primary screen monitor and the live viewer screen as the secondary Click Identify to see which screen is the primary screen 7 To set the eye tracker screen as the primary monitor select the eye tracker monitor in the Display list and then clear the Use this device as the primary monitor check box Note This check box is unavailable when you select the monitor icon that is currently set as the primary monitor For some graphics cards you need to click Advanced on the Settings tab to access this function 8 Make sure that the screens have the same resolution See the previous section for more information on how to set the screen resolution 9 Click OK or Apply to view the changes Note if the Display drop down list does not show the two monitor icons then Windows is not detecting the secondary monitor Check if the cables to the monitor are plugged into the right connectors that the connection source is set correctly on your monitor and whether your computer s graphics card supports dual view See the manual for your monitor for more information Windows Vista 1 Once the graphics card is installed with the card specific drivers and the two screens are connected to the computer open the Start menu on your computer and select Control Panel 2 Inthe Display Properties dialog box click the Settings tab 3 On the Settings tab you should see two icons representin
258. ticipant Groups Each row represents a participant group To select the Rows option 1 Click the Rows drop down list to view the available options 2 Select an option by clicking Summary only Recordings Participants or Participant Groups 3 If you select Participant Groups from the list select a group by checking clearing the group check boxes or create a new group by clicking New Participant Group See how to create a new group in the Creating a new participant group section above 4 Click anywhere outside the list to close it 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 119 and or other countries User Manual Tobii Studio 2 X When you select Recordings Participants or Participant Groups a global summary row or column will be displayed in the table or chart Clear the Show Summary check box if you wish to hide this row table or bar chart 9 3 1 3 Columns The Columns drop down list allows you to choose how the AOI data is calculated and displayed in table columns and the X axis of charts Columns SOls per Media AOI Media Summary O AO Group Summary E AO Metric Summary To select the Columns option 1 Click the Columns button The Columns list is displayed 2 Choose a setting by selecting the AOls per Media AOI Media Summary AOI Group Summary or AOI Metric summary chec
259. time L Media 1viewtime a i YY Fixation Before on AOI B in Media 1 5 9 4 3 1 N value This statistic describes the N value used to calculate other descriptive statistics such as the mean and standard deviation In the current metric it represents the number of recordings and is calculated as follows Row settings When recordings are selected as table rows the N value will always be equal to 1 128 tobii If participants are selected as table rows the N value will be equal to the number of recordings that participant has made with the same media element If participant groups are selected as rows then the N value will be equal to the number of recordings included in the group Summary columns In the AOI media summary columns the N value represents the number of recordings x the number of AOls included in a single media element In the AOI group summary columns the N value represents the number of recordings and follows the rules described in the previous paragraph row settings In the AOI metric summary columns the N value represents the number of Recordings x the total number of AOls i e all AOls included in all media elements 9 4 3 2 Brief description Number of times the participant fixates on the media before fixating on an AOI or AOI group for the first time count 9 4 4 First Fixation Duration seconds This metric measures the duration of the first fixation on an AOI or an AOI gr
260. tings distracted Enable user sound Smooth scaling i E o 2 3 O ae Full screen 7 Log History User Camera Live Viewer Start Recording Log History User Camera lji Status Ready ReadingandFaces 44 Recordings 8 Click Live Viewer to Start Live Viewer 9 Make sure the user camera and sound are enabled if so desired Click the Setup button on the Studio Logger header and click Enable user sound The user camera is enabled in Tobii Studio s Global Settings dialog box see step 3 To find the IP address of the Tobii Studio computer e f Multicast is selected and Tobii Studio Logger is being used for remote viewing on more than one remote computer enter the Multicast IP address displayed on the Screen and Video Capture tab in the Global Settings dialog box e f Tobii Studio Logger is open on only one computer follow the instructions below to find the IP address 1 For Windows Vista and Windows 7 open the Start Menu and type cmd in the Start menu search box The Start menu will display a list of items In the list and under the category Programs find and click cmd E md to open the Command Prompt Window 152 tobii For Windows XP Click the Start menu and click Run to open the Command Prompt Window 2 Inthe Command Prompt Window type ipconfig and press ENTER on your keyboard The computer IP address is displayed under Ethernet adapter Local Area Connection a
261. tive method should be considered e Participant The name of the test participant 7 2 1 Using independent variables to filter recordings Filtering allows you to restrict your data to a group of participants For example if you have created an independent variable called gender you can produce two separate heat maps for women and men by creating two filters one for males and another for females Each filter can be defined by either one independent variable or a combination of independent variables You can view select create and manage filters in the Recordings lists of the Visualization and Statistics tabs or with the Row options of the Statistics pane Use the Filter by drop down list located at the top of the Recordings list of the Selection pane to filter the recordings according to participant groups By default the button will display No Group Selected if no groups have been selected or created To create a new participant group 1 Click the Filter by drop down list This opens the Participant Groups list Filter by Participant Groups Ne f No Group Selected w is Create new participant group al o Rec ve wie 1 Rec 03 g7 W Rec 04 947 F Rec 05 93 V Rec 06 93 93 TAP ae o Rec 07 Ge T b T Rec 08 r Check Uncheck oe Pe re oe er r mme o a o ea ings Record 2 Click Create new participant group The New Participant Group di
262. to the clipboard and pasted into a document Scientific Project Tobii Studic Sox File View Tools ForSight Help Design and Record Replay Visualization Statistics aS Select Media o Recordings Metric Fixation Duration X Rows Participant Groups vw Columns AOls per Media X Media time Os to media end Filter by No Group Selected m Lal Calculate by Mean v Show V Tite 4 Legend V Point Values Set Max Value 1 Participant Recordi Date iy P01 Rec01 7 24120099 fw P02 Rec02 7 24 2009 12 7 P03 Rec03 7 24 2009 1 Po4 Rec04 7 24 2009 1 fy POS Rec05 7 24 2009 1 POG RecO6 7 26 2009 12 PO7 RecO7 7 26 2009 12 Pos RecO8 7 26 2009 12 Pog RecO9 7 26 2009 1 P10 Rec10 7 26 2009 1 Fation Duration Duraton of each individual factions within an AOI or within all AOls belonging to an AO Group seconds Read Full Description x 1044 Doo it TACMONG I Check Uncheck F F mI iv iv E la Areas of Interest tah emotional face tah E neutral faces v Ff DrawAngry JPG ReadingandFaces 7 DrawAngryEyes w 7 neutral eyes oo v DrawHappy JPG ReadingandFaces DrawHappyEyes eo 7 neutral eyes oo gt r DrawSad JPG ReadingandFaces Check Uncheck E Show Not on AOI Update Manual Auto The chart generated by the Statistics tool is a predefined bar chart w
263. ts the number of recordings and is calculated as follows Row settings When recordings are selected as table rows the N value will always be equal to 1 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 133 and or other countries User Manual Tobii Studio 2 X If participants are selected as table rows the N value will be equal to the number of recordings that participant has made with the same media element If participant groups are selected as rows then the N value will be equal to the number of recordings included in the group Summary columns In the AOI media summary columns the N value represents the number of recordings x the number of AOls included in a single media element In the AOI group summary columns the N value represents the number of recordings and follows the rules described in the previous paragraph row settings In the AOI metric summary columns the N value represents the number of recordings x total number of AOls i e all AOls included in all media elements 9 4 8 2 Brief description Number of times the participant fixates on an AOI or an AOI group count 9 4 9 Fixation Count zeros count This metric is calculated in the same way as Fixation Count with the exception that if at the end of the recording the participant has not fixated on the AOI the Fixation Count value
264. typing the new name and then pressing ENTER on your keyboard 3 Select the frame you want to add to the group The preview can be seen below the list fn Ben ioe pou cen Hid hoe eth pages oe papal loselhe in the l Cortert i imapi paan vi Tia tee chois belmar wh of ia predated i greapeng nedes or ab the praaping pournell by saiacting tha menuai UAL ord Sine Noe opten Dra ined haa bes ideien bets bo moke maraa serie ead PSE aan parE Heus Her Oo Pills Ll Conte ID Site Tiup liibi Parri u Dommiasd Spok l hiig iive oi paned T TE Yer eisa Saai hip wipes caa NT E Yai Bipr nse apntlp comian Prania G paify Bipr aave bth coraan Pria Sehhy hep Avenue eee OME PRA Vien bor ee Ohh Sorular Pradit irekie o 5 Hpi iw biy oiii ar Findus gee hii a oana TIHA E Yer d pai fon Piaduct geeis hij A a aa Ve ed Dirica Sy grees aptly contend Spo A paki of ie Qiewiieed Spotty 1 Aggie apathy conetien d pai A wool hiig i Gone CSRS Wad Yea Pip Sity pak A wel of hop ihwerropolly como A Bede Pram jth hipu eaei tp o or pai A wei ol hipio PIS a Products paa Spri del of hipoi p a TO a Parketi gre Aggy eee iiey i r pa Tau me hyng Ppa Perki peppa Hip e pehy eyra i p You at bug Sp hiipi p a EFI Te Yei Spy A world ol i You me barg Gp hipisi c a 1 2Gae1 Spoldp eal of hip ip A Tou we bang bp hip weipetiiyconfen Seer 12s _ paip A weld of Aen eae pen conten 11S Eii Spotlp lt 4 mri of Cpollp A mi ot Tou ae bung Spotty
265. u want to save your export then click Save The table is exported as a tab delimited TXT file To export a chart 1 Click the Export button to open the Export menu 2 Select Export Chart The Save As dialog box opens 3 Type the file name select the location where you want to save your export and then click Save The table is exported as an image in the PNG file format Note If more than one metric is chosen for analysis the image file will contain all the generated charts 148 tobii 10 Tobii Studio Logger The Tobii Studio Logger is a separate software component that can be opened on a remote computer to supervise a test and log events The Tobii Studio Logger is only available with the Enterprise license of Tobii Studio The Tobii Studio Logger displays a test screen with gaze data overlay Live Viewer and a user camera image The recordings are controlled and events can be logged from an external computer The Tobi Studio logger can be opened on a computer in the same or different room than where the test with the eye tracker and Tobii Studio is taking place It can also be used to show a recording in real time in a conference room Open the Windows Start menu select All Programs gt Tobii gt Studio then click Studio Logger to open the Studio Logger application Spotify Tobii Studio Logger File Help 10 46 1 103 WebTest Setup Category Shortcut Remote Desktop 10 46 1 103 test F2 Default None vr
266. uer dactuedeeneeteeneeeemnmudenseanae 105 AST Customizing Be i Streets nace var cece voc tees ctesesxe ete tee ees 106 8 Creating and Managing Areas Of INte rest sssssssssssssssssssssssssessssesosssssssssesesearaeseseseseeseneaeoeeseseseseeneneneaeaess 108 8 1 Or fergie pa seen ete mene ree eee ee 108 8 2 le aie AD cern cree ae ear iee terre omer tre eat eee ete ree re ee ee eee eee ee 109 8 3 2 igre A OLGO S aeenee ere erent EEEE ener ens ee eee 110 9 Calculating eye tracking metrics and statistics ssssusussusnunnununnunnunnnnunnnnnnnunnnnnnnannunnnnnnnunnunnnnannnnnnnannnnn ananman 113 9 1 Choosing media for the analysis sscscescgeecesestesccesscncsecaraet cose canesoeeseeaeenecssescencontanamemacnsteccenecaascesmesetemaceenes 113 9 2 SS CUM LAU scarce eo eane ene sa STE ra AIE Una a heuer e TE ANEN AO EEEE 115 gald ROO SINGS OR CNG Scarce ssc ca ca see esas a Ea 115 9 2 2 Selecting Areas of Interest cacao tenctec eet deans cntmtne big nae cttmeeicdeee ct etdewgi ees tedeaescteseea 117 9 3 Building tables and charts sicis ncyaisnnnssasivasnvosinanitassdtavnsassnncsiadexsure tavaiei eins sditunssstineneeeniaumniinarsialstiemnsnnammnane 118 9 3 1 Configuring tables and CAS secs acetiscicscSeesentinedepenenchensetesesaneenseetideusaninvdapaatnetepereseennietacestaeoabennic 118 9 3 2 Update and zoom OPTIONS sesaccsecessecseccecscseszayocacctesnsaecessnsaatdiunsisiwaseesaswacuaceincaieseawosvescioesstesuavacaeceeunsaeteuensts 125
267. und check boxes see section 11 2 1 of this manual pages 158 160 for details on how to set the user camera and sound Click the Preview Test icon to verify that the media is presented correctly see section 4 1 6 of this manual page 43 to learn how to preview a Tobii Studio test Make sure that you have the correct calibration settings see the section below 4 3 1 Calibration settings Before an eye tracking recording is started the user is taken through the calibration procedure During this procedure the eye tracker measures characteristics of the user s eyes and uses them together with an internal physiological 3D eye model to calculate gaze data This model includes information about shapes light refraction and reflection properties of the different parts of the eyes e g cornea and placement of the fovea During calibration the user is asked to look at specific points on the screen also known as calibration dots while several images of the eyes are collected and analyzed The resulting information is then integrated with the eye model and the gaze point for each image sample is calculated The default calibration process in Tobii Studio consists of a presentation of five calibration dots on a plain colored background The dots are presented successively and the participant must focus his or her visual attention on the center of the dots You can customize various features of the calibration procedure such as changing the number
268. ununnenunnnnunnnnnnnnnannnnnnnnnnnnnn nn nnnnn nnana ennnen 80 7 1 Selecting Medid oindre aaie EN aE Ged eaS AN A EE A Sohn 81 ki Grouping wep page Seri ne a a acta 82 7 2 Selecting TeC CLIN S sna a a E AA 84 7 2 1 Using independent variables to filter recordingS sssssssssssssrersrsrererenensnrnnnsnsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnns 85 7 3 Selecting data from a time interval asscaicrcitntionhe nahin vatiatdaiiiulalialinadiiniaine 86 7 4 Creating gaze DIOLS srine A a A a O acetate eta 87 TAN Cu stomizng gaze OIOLS ess cescceds tes cateostiuis a a a aA 88 7 5 Creating heat Map S ocasiriainei i iaeaea Sa E E rA ad EE EEEE N ST 89 FOT Customizing heat Mmap Sanc ae T a E 90 E02 Rowa heatmaps Calculated T naissuas a ten ey aneuanet 92 7 6 Creating Clusters nsiet iadair aa beaa e Aa isad e aiaee 96 AOT Customizing ClO SUCKS inean na a aa 97 Lo2 iNOW Ale CIUSTCIS calculated P cisci a a ea a aa a a a aa aia 98 7 7 Exporting gaze plots heat maps and clusters sssssssssssrsrerersrenennrnnnnnnnnnnnnnnnnnnnnnnnnanunnnnnnnnnnnnnnnnn nnana 101 klk BACKE esne enan N T E reee eden ade adeiaae 101 7 7 2 Animated WISUGNZAT ONS issciiect sects cezsenatcticirandenteexsecacsinasnssadecsextetncedasGsentensctectaesbeextextasunadectansieceideceemiemnientix 102 7 8 Displaying AOI overlays on gaze plots heat maps and CIUSLELS eects eteeeeeteteeteteeetetaetetaees 105 7 9 Creating bee swarm VINCOS sescsncenscsvesitrerenscemnsriaiearscaderneeeearneani ne
269. uring the test the image is presented in actual size but limited to the eye tracker s screen resolution For example if you are using a Tobi T60 or T120 Eye Tracker the maximum image size is 1280x1024 pixels while with a Tobii T60XL Eye Tracker the maximum is 1920x 1200 pixels Images larger than the eye tracker s screen resolution will be cropped for the presentation with the center of the image remaining at the center of the screen Use an image editing application such as Microsoft Office Picture Manager Microsoft Paint Photoshop Elements or Photopad Image Editor to resize an image To resize an image using Microsoft Office Picture Manager 1 oe pe a Open Microsoft Office Picture Manager can be found under Windows Start gt All Programs gt Microsoft Office gt Microsoft Office Tools Locate the image you wish to resize and select it Open the Picture menu from the menu bar and select Resize In the Resize task pane select Custom width x height Type the new width and height with values in pixels Click OK Open the File menu and select Save as to save a new image file with the new size To resize an image using Microsoft Paint oo O VS Open Microsoft Paint can be found under Windows Start gt All Programs gt Accessories Open the picture you would like to resize Click Resize Select the Pixels radio button and type the new horizontal and vertical values Click OK Open the File menu and sele
270. utes To specify how to stop the Web element recording tobii 1 Select the End recording after check box to set a time limit for the Web element session in seconds 2 If you choose not to select End recording after you move to the next media element during the test by pressing F10 on your keyboard Click OK once the selection has been made Since not all web pages are fully compatible with Internet Explorer 8 before starting the recording you need to set Internet Explorer 8 to run in compatibility mode To turn on the Internet Explorer 8 compatibility mode 1 Open Internet Explorer 2 Click the Tools menu and then select Compatibility View Settings K fy Live Search Reopen Last Browsing Session Pop up Blocker d Manage Add ons Work Offline De kli int Jij Compatibility View Settings Full Screen F11 Toolbars b Explorer Bars b lt k gt Developer Tools F12 Suggested Sites Internet Options 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 29 and or other countries User Manual Tobii Studio 2 X 3 In the Compatibility View Settings dialog box select the option Display all websites in Compatibility View 4 Click Close to accept the changes and close the dialog box Compatibility View Settings aan You can add and r
271. uto button is clicked all changes in settings and selections will take immediate effect and the tables or charts recalculation process triggered 9 3 2 2 Zoom settings The zoom controls of the table and chart display are located in the section to the right of the Update and Zoom toolbar The first set of controls is a drop down list with some commonly used preset zoom values and a button to reset the zoom level to 100 The second set of controls is composed of two buttons Zoom out and Zoom in and a zoom slider Move the slider to the left to zoom out in the display or click the Zoom out button To zoom in move the slider to the right or click the Zoom in button 9 4 Eye tracking metric definitions The main eye movement measurements used in Tobii Studio are based on two basic events fixations and mouse clicks In order to calculate the eye movement metrics you first have to define Areas of Interest AOls in your media The different metrics are then calculated in relation to these AOls e g Fixation Count on AOI A will be calculated as the number of fixations located inside the AOI A 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 125 and or other countries User Manual Tobii Studio 2 X The calculation of the metrics based on fixations is affected by the fixation filters settings By changing the settings or
272. value will be used to apply the color distribution mapping for more details see section 7 5 2 of this manual pages 92 96 To change the variable represented in the heat map 1 Click the Settings button in the lower left corner of the Visualization pane to open the heat map settings menu 2 Inthe Fixation data style area select Count Absolute duration or Relative duration To change the heat map style and color 1 Click the Settings button to open the heat map settings menu 2 Inthe Display settings area click the Style drop down list to select whether you want to use a colored heat map or a gaze opacity style The colored heat map uses a color gradient to display the areas with more or longer fixations while the gaze opacity heat map uses a transparency gradient The gaze opacity heat map shows the parts of the media with the highest counts or longest fixations and shades the rest of the media 3 Click the Color gradient box to open the Color Alpha Gradient Settings dialog box depending on the Style If heat map is the selected style the Color Gradient Settings will appear Click one of the three color boxes to change the colors of the heat map gradient The box on the left represents few fixations while the box on the right represents more fixations The Alpha Gradient Settings dialog box will open if gaze opacity was selected The number on the left represents few fixations and the number on the right represents more fixations The
273. vering over the ends of the segment once the pointer becomes a double headed arrow you can drag the segment to change the start and stop points In the Settings pane select the Snap to time markers check box to make the segment edges snap to the timeline tick marks Segments can be used to repeatedly play back the same section of the recording Click the infinity icon located just to the right of the segment name to loop one segment at a time 5 4 3 Exporting segments as videos Segments can be exported into an AVI video format that can then be viewed using an external media player To export a single segment to a video 1 Select the recording you wish to take the recording from 2 Click the segment menu arrow and select Export to AVI 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 65 and or other countries User Manual Tobii Studio 2 X 3 In the Export to video clip settings dialog box start by enabling disabling the user camera and sound 4 Select the user camera opacity and size 5 Select the codec you want to use to produce the video and type or select the frame rate of the video export 6 Click Save to export the video file a Export to video clip settings User camera settings V Enable user camera PiP Opacity V Enable user sound te 64040 Hint Position the PiP user camera by drag
274. viewable for qualitative analysis The user cam and timeline are optional in the fullscreen mode To view the replay in fullscreen mode 1 In the Replay pane right click the video 2 Select Fullscreen in the context menu 58 tobii When in fullscreen mode the Fullscreen menu can be accessed by right clicking the replay Exit Fullscreen ESC show Timeline T User Carera FiF E Increase User Camera FIP Opacity Up Decrease User Camera PIP Opacity Down The Fullscreen menu contains the option of hiding or displaying the timeline and user camera video e Show Timeline To be able to use all the functions of the timeline at the bottom of the fullscreen view press T on your keyboard e Exit Fullscreen To exit the fullscreen mode press ESC e User Camera PiP Shows the user camera as a picture in a picture The window can be dragged with the mouse to different positions press E on your keyboard e Increase Decrease User Camera PiP Opacity Increases and decreases the opacity of the user camera image over the replay press the UP ARROW and DOWN ARROW respectively 5 1 3 1 Changing the replay video settings In the lower left of the Replay pane is the Settings button Click the button to toggle between displaying and hiding some important replay Settings To modify the Overlay settings 1 Clear the Draw Gaze Data and Draw Mouse Clicks check boxes to hide the gaze data and mouse clicks during playback of the recording
275. wa Rec 01 e Show project details 6 The project name description author and new location can be changed by expanding the Show project details 7 Once the appropriate files and settings have been chosen click Import If a project with the same project ID already exists there are two options save the project as a new project or merge it with the old See the following section Merging Tobii Studio projects see section 2 5 of this manual pages 17 18 The project will appear in the project list when the import is finished 2 5 Merging Tobii Studio projects Tobii Studio allows you to create a project with one or more tests the parent project and then export this project to other Tobii Studio workstations where the test recordings can be carried out in parallel The recordings and eye tracking data can then be merged back into the original project for analysis A project with the same name must exist in the project list in order to merge two projects Note To ensure that the recordings are merged into the correct test do not make any changes to the test design and details in the secondary projects 2010 Tobii Technology All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 17 and or other countries User Manual Tobii Studio 2 X To merge two projects 7 Start Tobii Studio to open the Tobii Project Library dialog box C
276. will be registered as zero and the recording will be included in the descriptive statistics calculations e g when computing N and means 9 4 9 1 Brief description Number of times the participant fixates on an AOI or an AOI group count 9 4 10 Visit Duration seconds This metric measures the duration of each individual visit within an AOI or AOI group The N value used to calculate descriptive statistics is based on the number of visits see the N value description below for more details A visit is defined as the interval of time between the first fixation on the AOI and the next fixation outside the AOI If during the recording the participant returns to the same media element then the new fixations on the AOI will be included in the calculations of the metric If at the end of the recording the participant has not fixated on the AOI the Visit Duration value will not be computed and thus that recording will not be included in the descriptive statistics calculations e g when computing averages for participant groups 9 4 10 1 N value This statistic describes the N value used to calculate other descriptive statistics such as the mean and standard deviation In the current metric it represents the number of visits and is calculated as follows Row settings When recordings are selected as table rows N is equal to the total number of visits to an AOI If participants are selected as table rows N is equal to the total number of v
277. windowsxp using setup maintain improveperf mspx e Make sure that the energy saving options of your computer do not slow down the processor and other subsystems to save power or battery life This is especially important for laptops running on battery power e Running two displays simultaneously requires more video RAM and processor resources from your graphics card plus some additional management overhead in the graphics driver This can cause lower graphics performance and therefore lead to missed stimulus onsets when running complex stimuli on high resolution high refresh rate displays especially when using older mobile graphics chips with a low amount of local video RAM e Test the timing of your setup by following the test procedures described in Tobii Studio Timing Testing Guidelines Contact Tobii Support or your sales representative if you wish to receive a copy of the document Table 6 Hardware recommended configurations includes operating system and Studio versions Laptop Dell Precision Lee 1010 Dell Precision Core 2Duo 512 MB NVIDIA Windows 1 6 and later M6400 2 67GHz Quadro FX Vista 2700M Business SP2 Classic view Desktop Dell Precision Core 2Duo 4 GB 256 MB NVIDIA Windows XP 1 6 and later T5400 2 5GHz Quadro Professional FX570 SP3 Dell Precision T5400 Tele 7 Recommended stimulus Format Godee Size Framerate JPEG BMP 1280x1024 1920x1200 T60 XL a a pean Detailed documentatio
278. xternal device e g a second computer or TV Requires a video capture card installed on the computer running Tobii Studio a Scene Camera Used to analyze how people observe and interact with physical objects or external scenes The scene or object is integrated into Tobii Studio through an external camera Questionnaire Allows you to create and display multiple choice questionnaires that require a single answer during a recording The answers can be used to filter and compare data sets in the Tobii Studio visualizations and statistics tools at PDF Element Allows participants to navigate through a PDF document and move back and forth between the pages facilitating display of print ads newspaper spreads and other study objects in a more natural manner of interaction 4 1 2 1 Instruction An Instruction element is a text element that can be used to describe a task e g four images will be shown or to provide instructions to a participant during a test e g which key to click to move to the next slide An instruction can be placed anywhere on the timeline and is displayed as text on a customizable background To name the Instruction element 1 Type a name in the Element Name field To add and edit text 1 Type the text in the Preview field Add your text here 2 To the right of the field is a preview of the Instruction element 3 Change the font and color of the text by clicking the Font button and choosing from t
279. y All rights reserved Tobii Technology and the Tobii logo are either registered trademarks or trademarks of Tobii Technology in the United States 109 and or other countries User Manual Tobii Studio 2 X 3 Drag the AOI to move it to a new location on the image 4 Click outside the AOI to accept the changes and exit the edit mode 5 Inthe AOI list click the settings button 4 and then click Change Color to open a color palette and select a new color for the AOI 6 Rename the AOI by double clicking the AOI and typing a new name Alternatively you can double click the name in the Areas of Interest list and type a new name To edit an AOI that is overlapped by another AOI or AOls e g AOI A was created first and AOI B is overlapping AOI A 1 Select the overlapping AOI AOI B by clicking it CTRL clicking on multiple AOls to select multiple AOls and then right clicking 2 Inthe context menu select Send to Back The layer order of the AOls is changed i e AOI A will now be in front of AOI B 3 You can now click the AOI in front AOI A to edit it Bring to Front sends the AOI layer to the front of all the other layers AOls Bring Forward brings the AOI layer one step forward in the layer order Send Backwards sends the layer one step backward in the layer order Send to Back sends the AOI layer behind all other layers Note When calculating eye tracking metrics the fixations located in the overlapping zone of the two