Home
        Installation Instructions
         Contents
1.    The disposal of the end product is regulated in Germany by Elektro G  RoHS   internationally by  the EU Directive 2002 95 EG  RoHS  from 01 07 2006   or by any applicable national laws and  regulations   The end product is not regulated by the EU Directive 2002 96 EG  WEEE  and its  amendment EU Directive 2003 108 EG         et This floor lighting should not be disposed of with normal household waste   Sa    22 64412       DEWERT Antriebs  und Systemtechnik GmbH  Weststra  e 1    32278 Kirchlengern  Germany  Tel   49  0 5223 979 0   Fax   49  0 5223 75182   http    www dewert de  Info dewert de     44    PHOENIX MECANO    ID No   64412    
2.  handset    Depending on the version of your handset  the floor lighting can be switched on and off using either  one or two buttons                 A B    gt      0 8   lt   0O     O     Figure 7 Handset models  A UP button for the first motor on the double B DOWN button for the first motor on the  drive double drive    C Light button on the handset  when avail   able   Indicated with the following symbol  8    Turning on and off    The floor lighting can be turned on by simultaneously pressing the UP and DOWN buttons for the  double drive s first motor  The same two buttons can be used to turn off the floor lighting     Depending on the version of the handset  the UP and DOWN buttons for the double drive s first  motor are located either in the upper row of buttons or as the left most pair of buttons on the hand   set  refer Figure 7       gt  Some special handset versions have only a single button which is used for turning the lighting  on and off        Q For the battery drive emergency lowering option  The floor lighting should only be used  for short term illumination purposes  The floor lighting is not designed for long term use  because such use could cause the drive system batteries to discharge              Additional information about operating the handset can be found in the operating instructions in   cluded with your handset        Q Close off the unused handset sockets using dummy plugs  The protection against  splashed water is compromised with open sockets  I
3.  x 30  screw     also refer to Figure 5   The floor lighting must lie flat and level on its supporting surface  It  should only be fastened under the end product or to a double drive  In the end product  no me   chanical forces should be put on the floor lighting  Such forces could lead to damage  such as  cracks  in the housing                    Figure 5 Mounting holes in the floor lighting  dimensions in mm     64412       Floor lighting Installation    5 2 2 Mounting the floor lighting onto the end product  1 Select a suitable location for attaching the floor lighting     2 Use at least two screws per lamp when attaching the floor lighting   The mounting holes are  shown in Figure 5     3 Connect the floor lighting plug to the attached double drive or to the corresponding socket on  the drive control unit        A For versions with IP44 and IP66 protection  Do not use a plug unless it has a sealing  washer  Both the floor lighting plug and the handset plug must have a sealing washer   The washers ensure that the connections are properly protected against any splashed  water           4 Connect the handset plug to the handset socket on the floor lighting  if available  refer to Figure  2     5 Snap on the shield cover  The handset plug is securely connected to the drive once the cover is  properly snapped on     6 Close off the unused handset sockets using dummy plugs     64412    15    Installation    5 2 3    16    Floor lighting    Mounting the floor lighting to a doubl
4. Check the housing for breaks or  cracks     Check that all electrical cables  and connections are firmly seated  and correctly positioned    Check the connecting cables for  pinching or shearing  Also check  the strain relief and kink protec   tions mechanisms  in particular af   ter any mechanical load     This floor lighting was designed so that it would be easy to clean     sult        Time interval    Periodic inspections can  be carried out at intervals  based on the risk as   sessment which you con     duct for your end product     At least every six months    At least every six months    At least every six months    Never clean the floor lighting in an automated washing system or with a high pressure  Q cleaner  Do not allow fluids to penetrate the lighting  Damage to the lighting could re     Do not use a cleanser that contains benzene  alcohol or similar solvents           Always disconnect the mains power plug before you start to clean the drive     2 Use a standard cleanser that is suited for plastics when cleaning the floor lighting  or use a  moist cloth  Follow the usage instructions provided with the cleanser     3 Be sure that you do not damage the connecting cables during the cleaning     64412       21    Disposal Floor lighting    9  Disposal    This floor lighting consists of electronic components  cables and metal and plastic parts  You  should observe all corresponding national and regional environmental regulations when disposing  of the floor lighting 
5. PHOENIX MECANO       Installation Instructions    Floor lighting    64412       Floor lighting Foreword    Foreword   Revisions  Version Date Changes      06 09 First edition    Disclaimer and exclusion of liability  DEWERT is not responsible for damage resulting from   e failure to observe these instructions   e changes made to this product which have not been approved by DEWERT  or  e the use of replacement parts which have not been approved or manufactured by DEWERT     Contact addresses     44 DEWERT Antriebs  und Systemtechnik GmbH  PHOENIX MECANO Weststra  e 1  32278 Kirchlengern  Germany  Tel   49  0 5223 979 0  Fax   49  0 5223 75182  http   www dewert de  Info dewert de    Creation of a complete operating instruction manual for the entire end product    These instructions are only intended to be used by the end product manufacturer  They should not  be given to the operator ofthe end product  The factual information contained within may be used  as a basis when creating the end product manual     The warning and danger notices may be particularly suited for use in the end product s manual   However it is not sufficient to simply follow these notices  You should also carry out an internal risk  assessment for your end product  This can then be used as the basis for the safety notices in your  manual     64412    3    Foreword Floor lighting    EU Declaration of conformity    In compliance with Appendix IV of the EU EMC Directive 2004 108 EG  In compliance with Appendi
6. bles from coming into contact with the floor during transport     17    Notices for operation Floor lighting    6     6 1    18    Notices for operation    The factual information contained within may be used when you are creating the end product man   ual  The installation instructions do not contain all information required for the safe operation of the  end product  They only describe the assembly and operation of the floor lighting and do not de   scribe the completed end product        A When creating the operating instructions  remember that the installation instructions  are intended for qualified specialists and are not for typical users of the end product           General notice     gt  Only handsets from DEWERT should be connected to the floor lighting since they have already  been verified to work together     Avoiding damage from laser light    Be sure that your operating instructions inform the user about the possible risks associated with la   sers        Do not look directly into this light and do not point the light into other people s eyes           Avoiding cable damage  Be sure that your operating instructions inform the user about the possible cable risks        A The cables  particularly the connecting cable  should not be run over  In order to pre   vent injuries or damage to the floor lighting  no mechanical strain should be placed on  the cables           64412       Floor lighting Notices for operation    6 2    64412       Examples of how to use the
7. e drive  for example  the DUOMAT 8     If you have purchased the  single body lamp for assembly on a double drive  version of the floor  lighting  then the floor lighting should be attached directly to the double drive                       F F   Figure 6 Mounting to a double drive  for example  the DUOMAT 8    A DUOMAT 8 double drive B Socket on the DUOMAT 8 double drive   C Support dome on the double drive D Mounting holes on the floor lighting   E Floor lighting F Threaded screw connection on support   dome   1 Place the floor lighting onto the support dome of the double drive  The double drive should al   ready be attached to the end product    2 Use two screws  for example  two 3 9 x 15 mm screws  to attach the floor lighting to the support  dome on the double drive    3 Connect the plug on the floor lighting to the double drive     64412       Floor lighting Installation    5 2 4    64412       Electrical connection       A Electrical components should be connected or disconnected only when the mains  power cord is unplugged           Routing electrical cables   When routing the cables  be sure that    e the cables cannot get jammed    e no mechanical load  such as pulling  pushing or bending  will be put on the cables  and  e the cables cannot be damaged in any way     Fasten all cables  especially the connecting cables  to the end product using sufficient strain relief  and kink prevention methods  Be sure that the design of the end product prevents the connecting  ca
8. e on safety during operations    Product labelling  Description of lighting  Technical Specifications    Installation  Safety notices to observe during installation    Installation procedure    Notices for operation  General notice    Examples of how to use the handset  Troubleshooting    Maintenance  Recommended maintenance and inspection intervals    Cleaning and care    Disposal    Table of Contents    br WO O WOW WwW       e gt      oe oo oNN    10    11    13  13  14    18  18  19    20    21  21    21    22    General    1     1 1    1 2    Floor lighting    General    About these installation instructions    In order to install this drive successfully and safely in the end product  these installation instructions  must be observed  These instructions are not an operating manual for the end product     These instructions will help you to minimize danger  repair costs and down times  They will also  help you to maximize the reliability and lifespan of the end product        The notices in these instructions must be followed  Their observance during installation  A and connection will help to minimize    e the risk of accident and injury  and  e damage to the floor lighting or the end product           These installation instructions have been written with due care and attention  However  unless oth   erwise required by law  we do not guarantee that the data  images and drawings are accurate or  complete nor do we accept liability for their contents      gt  We reserve th
9. e right to make unannounced technical changes in the course of our continual  product improvement process     Conventions used  Notices which do not relate to safety are indicated in these instructions with a triangular symbol      gt  Notice symbol    Explanations of warning notices       DANGER indicates a hazardous situation which  if not avoided  will result in serious in   jury or death           WARNING indicates a hazardous situation which  if not avoided  could result in serious  injury or death           moderate injury           NOTICE is used to address practices which are not related to personal injury but may    A CAUTION indicates a hazardous situation which  if not avoided  could result in minor or       result in damage to the product or surroundings        64412       Floor lighting Safety Notices    2     2 1    64412       Safety Notices    Proper and intended usage  The floor lighting is intended to be installed in an end product   e to illuminate under furniture such as hospital beds     e for connecting to double drives and drive control units to provide motor adjustment capabilities  for movable furniture and hospital beds  and    e for connecting up to two handsets  depending on the design         A The floor lighting should only be used for the applications described above  Any other  application is not permitted and can lead to accidents or damage to the unit  Such non   approved applications will lead immediately to the expiration of all guarantee a
10. es for mounting on the end  drive product   C Mounting holes for mounting on the end D Handset socket  product    E Snap on shield cover  with the IP44 IP66 F Mounting holes for mounting onto the  version DUOMAT 8 double drive    G Mounting component of lamp    64412       Floor lighting    Technical Specifications    4  Technical Specifications    Input voltage   Protection classification  Light source   Light emitted from diodes  Protection category  Colours   Dimensions and weight  Length x width x height  Version with socket  Version without socket  Weight   Ambient conditions  Ambient temperature  Relative humidity    Air pressure    24V DC   lil   LEDs   LASER CLASS 1  EN 60825 1 1994   IP20  optionally IP44   IP66    Grey   Black    92 mm x 65 mm x 48 mm  92 mm x 54 mm x 48 mm    Approx  100 g     10   C to  40  C  30  to 75   700 hPa to 1060 hPa                64412       11       Technical Specifications Floor lighting          65             Figure 3 Dimensions of floor lighting with socket for handset  in mm  and cable connection          92             Figure 4 Dimensions of floor lighting  for attachment to double drive  in mm     12 64412       Floor lighting Installation    5     5 1    64412       Installation    Safety notices to observe during installation    Basic safety rules must be followed in order to ensure that the end product can be continually op   erated in a safe manner  These rules must be observed while using the end product and while in   stall
11. ing plate example  Under bed floor light Model name  62304 Article number  U in  24 V Input voltage  Baujahr  Prod Date  Calendar week   year  Seriennr  Serial No   Serial number of the floor lighting         IP20    Ce    A    Vx XX    Use in dry rooms only     Protection category    Mark of CE conformity    Follow special disposal instructions     Software version number  when available        Description of lighting Floor lighting    3     10    Description of lighting    The floor lighting is used exclusively for illumination under furniture or hospital beds  It is used to   gether with a DEWERT double drive and can be mounted either directly to the double drive or un   der the end product  A handset can be connected if the floor lighting is equipped with a handset  socket      gt  We reserve the right to make unannounced technical changes in the course of our continual  product improvement process     The floor lighting is available in the following different versions     as asingle body lamp with one socket for a handset     as asingle body lamp without a socket for a handset       as a single body lamp with one socket for a handset  for assembly  on the DUOMAT 8 double drive     e as adouble body lamp with a socket for a handset     as adouble body lamp with two sockets for handsets  or  e as adouble body lamp without a socket for a handset                    Figure 2 Floor lighting lamp  with handset socket   A Cable or plug for connecting to the double B Mounting hol
12. ing the floor lighting     Ensuring operational reliability during installation    The safety and reliability of the end product containing DEWERT components can be ensured by  using the proper construction methods described below        A Make sure that the floor lighting is positioned so that it is not possible for someone to  look directly into the light        For versions with IP44 and IP66 protection  Do not use a plug unless it has a sealing  washer  Both the floor lighting plug and the handset plug must have a sealing washer   The washers ensure that the connections are properly protected against any splashed  water     An additional shield cover to protect against unplugging is also required for IP66 pro   tection  This shield cover can only be removed with a screwdriver                    Q Do not remove the dummy plugs from the unused handset sockets on the floor lighting           13    Installation Floor lighting    5 2    5 2 1    14    Installation procedure    Before installing the floor lighting  make sure that you are observing all ofthe safety notices found  in the  Safety notices to observe during installation  section     Installation and dismounting for the floor lighting          The mains power plug on the drive should be unplugged during the installation        The floor lighting can be screwed onto the end product using the mounting holes  Use at least two  suitable screws  for example  at mounting hole A  a 3 9 x 15 screw  at mounting point B  a 3 9
13. n extreme cases  such open sock   ets can lead to the destruction of the floor lighting or the drive           19    Troubleshooting Floor lighting    7  Troubleshooting    This chapter describes troubleshooting methods for fixing problems  If you experience an error that  is not listed in this table  please contact your supplier        A Only qualified specialists who have received electrician training should carry out trou   bleshooting and repairs           The floor lighting is not There is no mains supply volt  Connect the mains power   functioning age   The power feed  from the mains  Check the lead in connections and  has been interrupted  re seat the contacts if required   The LED is defective  Please contact your supplier or  sales agent    20 64412       Floor lighting    8  Maintenance          Maintenance    You should only use spare parts which have been manufactured or approved by  DEWERT  Only these parts will guarantee a sufficient level of safety           8 1 Recommended maintenance and inspection intervals    Type of check    Check the function and safety  of the electrical system    Periodic visual inspection for  housing damage    Periodic visual inspection of  the plug in connections and  electrical access points for  damage    Periodic visual inspection for  cable damage    8 2 Cleaning and care    Explanation    A qualified electrician should carry  out this inspection   Refer to the   Electrical connection  section in  the  Installation  chapter      
14. nd war   ranty claims on the part of the end product manufacturer against DEWERT           Improper usage    Be sure to follow the notices below concerning improper usage  You should include them in your  product manual in order to inform your end product users     The floor lighting should not be used     A e in any environment where combustible or explosive gases or vapours  e g   anaes   thesiology  may be present     e in a moist environment  or  e outdoors                  The floor lighting may not be operated by    e small children            You should only use spare parts which have been manufactured or approved by       DEWERT  Only these parts will guarantee a sufficient level of safety        Safety Notices Floor lighting    2 2    2 3    2 3 1    Selection and qualification of personnel    This floor lighting should only be installed into the end product by someone who has completed  training in electronic motor assembly or has equivalent qualifications     You should only install this floor lighting when you are qualified to do so  Otherwise  a properly  qualified person should be found for this task     Notice on safety during operations    Basic safety rules must be followed in order to ensure that the end product can be continually op   erated in a safe manner  These rules must be observed while using the end product and while in   stalling the floor lighting     These rules and safety measures can be categorized as follows     e construction measures before 
15. the installation  refer to the  Ensuring operational reliability during  installation  section in the chapter  Installation       e safety fundamentals during the installation of the floor lighting and during cable and wire routing   refer to the  Electrical connection  section in the chapter  Installation       e basic safety rules during operation  refer to the chapter  Notices for operation    and  e the creation of a manual for the end product which contains these and other safety rules     Creating a user s manual    The manufacturer of the end product must create a manual for the user of that product  The safety  notices in the end product manual must be written based on the end product s risk assessment     64412       Floor lighting    2 4  2 4 1    64412       Product labelling    Type label    Safety Notices    A rating plate or  type label  on each drive specifies the exact name and serial number of the drive   It also states the technical specifications valid for that particular drive  The following illustration  shows where the specifications are located on the rating plate of the floor lighting      gt  The rating plate shown is an example  the specifications for your floor lighting may differ from  this illustration           UB Licht Floorlight 62304              vee  M C      Baujahr  Prod Date      46 08  Seriennr  Serial No    C123456 0001 X    MAAA AAA a    IP20       Vor Feuchtigkeit sch  tzen DEWERT  Indoor use only A Phoenix Mecano Company  Figure 1 Rat
16. x III of the EU Low Voltage Directive 2006 95 EG    The manufacturer    DEWERT Antriebs  und Systemtechnik GmbH  Weststra  e 1   32278 Kirchlengern  Germany    declares that the following product  Floor lighting with DEWERT control unit    meets the requirements of the following EU directives     e Electromagnetic Compatibility Directive 2004 108 EG  e Low Voltage Directive 2006 95 EG    Applied standards       EN 60335 1 2002 A2 2006   e EN 55014 1 2006   e EN 55014 2 1997 A1 2001   e EN 61000 3 2 2006   e EN 61000 3 3 1995 A2 2005      EN 50366 2003 A1 2006  measured distance  5cm   e In accordance with EN 60601 1 1990 A2 1995    This declaration of conformity is no longer valid if constructional changes are made which signifi   cantly change the control unit  i e   which influence the technical specifications found in the instruc   tions or the intended use      Kirchlengern  Germany  on the 21 07 2009 Andreas Hoither  Managing Director R amp D and Engineering    4 64412       Floor lighting    Table of Contents    Foreword    Revisions    Disclaimer and exclusion of liability    Contact addresses    Creation of a complete operating instruction manual for the entire end product    EU Declaration of conformity    Table of Contents    1 1  1 2    2 1  2 2  2 3  2 4    5 1  5 2    6 1  6 2    8 1  8 2    64412       General  About these installation instructions    Conventions used    Safety Notices   Proper and intended usage   Selection and qualification of personnel  Notic
    