Home

Godox QS Monolight Instruction Manual

image

Contents

1. output controller 5 Sync Triggering The sync cord jack 2 is a 6 35mm plug Insert a trigger plug here and the flash will be fired synchronously with the camera shutter Slave Trigger Model Three slave triggering models are available and can be set by pressing Slave Model Button 8 No optical control The slave triggering indicator 13 is off indicating the slave triggering function is shut down One fire model The slave triggering indicator 13 glows blue indicating the flash will fire synchronously when receiving one external flash In this model the flash can function as an auxiliary lamp offering various effects of light and shadow Anti preflash model The slave triggering indicator 13 glows red indicating the flash will receive two external flashes within 2 seconds and will fire synchronously when receiving the second flash In this model the flash can function as an auxiliary lamp applicable to TTL system With this anti preflash function the flash can synchronize with cameras having a one preflash firing system Buzz Function The sound button 7 is used for deciding whether there is sound reminder for ready flash after recharging When the buzz indicator 12 is on the buzz function is working when it is off the buzz function is not working A BI sound will be heard when it s fully charged 05 e Memory Function The device is equipped with memory function for the panel sett
2. product can be used in combination with the following accessories sold e Body separately so as to achieve best photography effects Godox FT series remote control Power Inverter Softbox Photographic Umbrella 15 fimm 19 Light Stand Barndoor Snoot etc 10 12 4 G0d0x 13 04 ER 98 eg 05 11 14 07 29 08 06 09 17 03 02 OPERATIONS 16 e Flash Preparation 01 1 Take down the lamp cover Install the modeling 18 20 lamp and put on the glass protection cover and the standard reflector To uninstall the standard reflector press the release button on the flash head 01 AC Power Socket 11 Modeling Lamp Indicator ane nee tangle 02 S Cord Jack 12 B Indi reflector counter clockwise y BYR SAO eet Buzz Indicator to take it out as illustrated 03 Power Switch 13 Slave Triggering Indicator in the picture da dig t c Controler hi ps Pu amp 2 Attach the flash unit onto an appropriate light stand Adjust the mounting Flash Output Controller Light Sensor bracket 18 for a good angle and make sure it is tightened and fixed Use the 06 Modeling Lamp Button 16 Fuse direction adjusting handle 20 to adjust the flash to a desired direction Umbrella 07 Sound Button 17 Wireless Control Port input 19 is for different photo umbrellas to put in 08 Slave Model Button 18 Mounting Bracket 09 Test Button 19 Umbrella Input e Power Connection 10 Digital Display 20 Direction Adjusting Handle Use the power cord to conne
3. 0 QS800 QS1200 Max Power Ws 300Ws 400Ws 600Ws 800Ws 1200Ws Guide Number m ISO 100 58 65 76 90 110 Color Temperature Operating Voltage Power Output Control 5600 200k AC200 240V 50Hz or AC100 120V 60Hz OFF 5 0 8 0 1 32 1 1 Modeling Lamp W 150W Recycle Time BI ec es rss UT SEFHQSZRUSZZEDJJGA Uber misAMA Nees REX SHU SSNS wes EELAM LFE sat wins ibis AGU RNS mA 3022 AT RE LEDER TAM 5 0 8 07 ERE rSn HARE 150WAJZSjE AJ REAR iE ARE EH SE HAT ERI 276 IRANIE ais BAYS LARS GE RT SCUBA TERES EIUBNFBIJBE IRAE AMIE Mm pose Banc FALE aK ES ERATE T Aes ETB ATREA WSBT FAA WRG Triggering Method Flash Duration Sync cord Test button Slave triggering Wireless control port 1 2000 1 800s SIA Fuse 5A 8A 10A Dimension Flash diameter 14cm height of flash with handle 23cm length of flash with lamp length of flash with lamp cover 41cm cover 51 15cm Net Weight Approx 2 7kg Approx 2 8kg Approx 3kg Approx 3 7kg Approx 3 9kg MAINTENANCE Shut down the device immediately when it works abnormally and find out the reason Avoid sudden impacts and the lamp should be dedusted regularly It is normal for the lamp to be warm when in use Avoid continuous flashes if unnecessary Maintenance of the flash must be performed by our authorized maintenance department which can provide original accessories The flash tube and the modeling lamp are user replaceable Replaceme
4. RU rote Base ES RARI GODOX Photo Equipment Co Ltd XEXIE Add FAY Z PCT tA SAB oA eT EA ATI 2 F Building A4 Xinhe Huafa Industrial Zone Fuhai RD West Fuyong Town Baoan District Shenzhen 518103 China FBi amp Tel 86 755 25701197 86 755 25726373 E Fax 86 755 25723423 Hib48 E mail godox godox com 82 A0000QS1 00 VC jejeje m4 QS senes SW SWICK Professional Studio Flash _ c Instruction Manual 7 20 E S1 Chinese English Bilingual r3 amp sr3yi amp _ FOREWORD Thanks for choosing QS series studio flash It is a durable and high performance strobe with complete functions to help professional photographers create desired lighting effects This product is suited for wedding advertisement portrait and fashion photography The perfect light source and a Must in studios and photo workshops The QS flash offers Precise output control 30 steps from 5 0 8 0 in 0 1 increments High qualified modeling lamp 150W output steplessly adjustable Outstanding output stability a tolerance of x 2 under the same output Anti preflash function enabling synchronization with cameras having a one preflash firing system Automatic power discharge when the flash output is adjusted from high to low Adjusted parameters intelligently remembered after 3s and automatically recovered after a restart Wireless control of the flash power ratio the on and off of modeling lamp and buzzer as we
5. ct the flash to an AC power source and turn on the power switch 3 The lamp on the power switch turns on indicating it s connected Accessories Sync Cord e Modeling Lamp Power Cord Modeling Lamp Button 6 controls the modeling lamp status when modeling Standard Reflector lamp indicator lights up modeling lamp is on if not modeling lamp is off Lamp Cover Modeling lamp output controller 4 is used for adjusting the power output level of Glass Protection Cover Modeling Lamp Instruction Manual modeling lamp Modeling lamp will be off automatically after lighting for 2 hours avoiding overheat due to long time lighting when the user is not nearby oo ds S5 Iw ees s 04 modeling lamp on for a long time It is recommended to cool it down for one minute after 10 minutes working When there is flammable accessory on the flash unit do not keep the Power Output Control Flash output controller 5 decides different power output satisfying light requirements in different environment The power is adjustable freely from 5 0 to 8 0 which will be accordingly shown on the digital display 10 OF on the display indicates that the flash triggering function is turned off It can automatically discharge power when the flash output is adjusted from high to low Test Button To fire the flash without taking a picture press the test button 9 It can also help adjust the flash brightness when combined with the flash
6. evice in a closed vehicle in the sun or in other areas subject to extremely high temperature Failure to observe this precaution could result in fire or damage to the housing or internal parts CAUTION A A gt gt PP Bb p After 30 continuous flashes at full power the flash should be cooled down for about 3 minutes Overheating will occur if it is used continuously without cooling down Do not keep using the modeling lamp for a long time otherwise flammable accessories attaching to flash head e g softbox will get burnt A 10 minute time is recommended in this case After 10 minutes cool it down for 1 minute When using a snoot do not keep the modeling lamp on for a long time or fire too frequently not over six times for one minute Overheating will result in damages for strobe housing and or studio light Do not touch the lamp cap when the flash or modeling lamp is working as it will give out heat leading to high surface temperature Do not touch the two terminals of the tube outlet as there is high voltage inside Wear insolated gloves before replacing the tube or modeling lamp Avoid sudden impacts as this can damage the flash tube and or modeling lamp Do not flash directly towards naked eyes especially those of babies otherwise it may lead to visual impairment Disconnect from the power supply when it will not be used for an extended period 02 _ NAMES OF PARTS e Separately sold accessories The
7. ing It will help remember the panel setting 3 seconds after you set it When starting up the flash next time the panel setting will be the same as that before powering it off Wireless Control Function The flash unit is built in with a Wireless Control Port 17 so that you can wirelessly control the on and off of your flash modeling lamp and buzzer as well as adjust the flash output level etc To control the flash wirelessly you need a Godox FT series remote control set on camera and on flash Insert its receive end into the Wireless Control Port 17 on the flash and insert the transmit end into the camera hot shoe Settings made on the hotshoe mounted transmit and receive ends will be wirelessly communicated to the flash Then you can press the camera shutter release button to trigger the flash For full instructions on the use of FT series remote control see its user manual Tube Replacement Shut down the power and remove the power cord before replacing the flash tube Wear insulated gloves to loosen the iron wire on the tube keep a balanced hold on the two feet of the flash tube and pull out the old tube gently Take down the feet casing from the old tube and put it on the new one Hold two feet of the new tube and target directly towards the two copper outlets then push them slightly in Twine the iron wire on the stainless steel sheet to fix the flash tube 06 _ TECHNICAL DATA Model QS300 QS400 QS60
8. ll as flash triggering CONTENTS 01 01 02 02 03 03 03 04 04 04 04 04 05 05 05 05 05 05 06 06 07 07 Foreword For Your Safety Caution Names of Parts e Body Accessories e Separately Sold Accessories Operations Flash Preparation e Power Connection e Modeling Lamp Power Output Control Test Button e Sync Triggering e Slave Trigger Model e Buzz Function e Memory Function Wireless Control Function Tube Replacement Technical Data Maintenance FOR YOUR SAFETY To prevent damage to the product or injury to you or to others read the following safety precautions in their entirety before using this device Keep these safety instructions where users can read them for ready reference A Do not disassemble or modify There are high voltage components inside the unit Failure to observe this precaution could result in electric shock or product malfunction Should the product break open as the result of a fall or other accident send the defective back to the authorized service center for inspection and maintenance Keep dry Do not handle with wet hands immerse in water or expose to rain Failure to observe this precaution could result in fire or electric shock Keep out of reach of children This device contains small parts that may pose a choking hazard Consult a physician immediately if a child swallows any part of this device Do not expose to high temperature Do not leave the d
9. nt tubes and lamps can be obtained from the manufacturer This product except consumables e g flash tube and modeling lamp is supported with a one year warranty Unauthorized service will void the warranty If the product had failures or was wetted do not use it until it is repaired by professional Disconnect the power when cleaning the flash or when changing the flashtube modeling lamp Changes made to the specifications or designs may not be reflected in this manual 07 08 BIS 09 ZEMA 09 RRN 10 BB 10 lE 10 ppt 11 mpl pp t 11 EB 11 HENX 11 BEJ 11 EXT BAR 12 PRAD 12 WIH 12 E 12 gt SGA 12 Bete 12 OEBE 12 gt Foe HITE 13 BEATE 13 mo 14 RF dS

Download Pdf Manuals

image

Related Search

Related Contents

Zalman ZM-HE100 USB powered    LokPilot Basic  Altronix MAXIMAL55D power distribution unit PDU  "取扱説明書"  スーパーショーケース - 電気・建築設備エコソリューション  

Copyright © All rights reserved.