Home

ManTooth Users Guide.indd

image

Contents

1. MantTooth Dual Pressure Wireless Digital P T Gauge ManTooth Single Pressure Wireless Digital P T Gauge Made for iPhone LliPad Made for iPhone 6 Plus iPhone 6 iPhone 5s iPhone 5c iPhone 5 iPhone 4s iPhone 4 iPad Air 2 iPad Air iPad mini 3 iPad with Retina display iPad 4th generation iPad 3rd generation iPad 2 User s M Made for iPhone and Made for iPad mean that an electronic accessory has been designed to connect specifically to iPhone or iPad respectively and has been certified by the developer to meet Apple performance standards Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards Please note that the use of this accessory with iPhone or iPad may affect wireless performance YELLOW JACKET Bluetooth iPhone iPad and Retina are trademarks of Apple Inc registered in the U S and other countries iPad Air and iPad mini are trademarks of Apple Inc Android and Google Play are trademarks of Google Inc The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any use of such marks by Ritchie Engineering is under license Available on the E App Store GET IT OW Google play a F Other trademarks and trade names are those of their respective owners Before You Start Contacting Ritchie i To order accessories receive assistan
2. Proof Tolerable pressure without 1000 psia Radio Burst Pressure Tolerable pressure without 6 long x 1 6 wide x 2 3 thick loss of seal 15 one Temperature Sensing element Superheat Ee ee by instrument 40 C to 130 C Max and Min Displays and records the Max Cord temp Pressures maximum and minimum 176 F 80 C pressures mien camp Temp Refrigerant 98 NIST refrigerant profiles 203 F 95 C Database included upgradeable 14 Sire Screenshot feature allows you to Save pressure and temperature readings from your sessions which can be automatically organized by location and unit being serviced Screenshots Temperature Capable of measuring two Sensors temperatures using high accuracy NTC thermistors Pressure 67001 One pressure transducer Transducers 67002 Two pressure transducers System Very small internal volume attachment minimizes refrigerant loss during system analysis Standard manifolds and hoses can lose over 50 times more refrigerant with each connection Zeroing the start of each session Elevation Enter elevation at the start of Compensation the session for effortless psia compensation Rechargeable LiPo battery for long battery life and excellent recharging capability for the life of your ManTooth 15 Warranty Policy The YELLOW JACKET ManTooth Wireless Digital P T Gauge from Ritchie Engineering Company Inc is guaranteed to be free from material and workmanship de
3. To set the subcooling and superheat values tap on the Subcooling or Superheat box and enter the data requested For subcooling just enter the the desired value for subcooling For ll superheat enter the outdoor dry bulb temperature and the indoor wet bulb temperature The app will then take this data and automatically calculate the target superheat value Once you have entered the necessary information save the values by taping on the save icon in the top right corner of the screen Target Superheat Outdoor Dry Bulb Temp Indoor Wet Bulb Temp Saving Data To save the data currently on the screen tap on the screen shot icon on the top right corner of the readings screen Readings High Pressure 0 0 psig Low Temp High Temp 75 0 75 0 Exit Session Clear Readings Preview Superheat Subcooling Save amp Email Once you choose to save the data you will be given the option to save and email which will save it to your session history and imbed the data into an email report for you to send to whoever you want discard the snapshot you just took or just save it to your session history for later reference and use Note the phone or tablet you are using must be connected to cellular service or WiFi to send emails If your phone or tablet does not have the proper service to send an email when the screen shots are taken you can save the data and then access it at any time from the
4. avg max Liquid Saturation UNASSIGNED High Temp UNASSIGNED Superheat Subcooling Target Calc Target Cale Exit Session Clear Readings Refrigerant The refrigerant for the session can be changed by taping on the refrigerant and selecting the refrigerant that is in the equipment you are currently working with If you forgot or selected the wrong refrigerant in the Session Settings this is where the refrigerant can be changed Pressure To assign pressure readings to either the high or low side simply tap on the box that contains the value you wish to assign and select the sensor that you want to assign to that spot Note on dual units with 2 transducers the main unit is 1 and the tethered unit is 2 If you are using two single units reference the device name serial number to determine which pressure is associated with which device Low Pressure 0 0 psig YJPT 1415 0003 1 0 0 psig YJPT 1415 0003 2 Liquid and Vapor Saturation Liquid and Vapor Saturation values are calculated automatically by the app based on the measured pressure and the refrigerant selected Temperature To assign temperature readings to either the high or low side simply tap on the box that contains the value you wish to assign and select the sensor that you want to assign to that spot Note the label on the ManTooth PT Module denotes which temperature port is T1 and which is T2 for easy reference Subcooling and Superheat
5. first screen available upon opening the ManTooth RSA app tap on the gear in the upper right corner of the screen ManTooth RSA xt lt Pressure Temperature App This application requires special Yellow Jacket R bluetooth pressure and temperature sensing devices For each bluetooth device being used the initial pairing with this mobile device must be done using the bluetooth settings utility After the one time initial pairing simply turn the bluetooth devices on and start a session below Start Session Service History General Settings Your Information Name mpany Locations and Equipment Edit Locations Equipment Temperature Preference Fahrenheit Celsius Pressure Preference psig Auto Sleep Service Management Your Information Here you can set your own name and your company name This information will automatically appear in the e mails containing the system readings which you can send directly from within the app Locations and Equipment Here you are able to create new locations add additional units to existing locations remove units from locations or completely remove existing locations Note If you delete an entire location all screen shots associated with this location and any equipment at this location will all be deleted Deleted locations and associated screen shots can not be retrieved Similarly if you delete equipment from a location the screen shots associated wit
6. On Apple iOS devices once your ManTooth PT Module is paired if it is listed as Connected the light on the module will glow a solid blue However on all Android devices or if your iOS device lists your ManTooth PT Module as Not Connected the light will continue to blink blue This is normal ManTooth RSA App This section will go over the various functions settings and procedures of the ManTooth RSA Pressure Temperature App ManTooth RSA ro Pressure Temperature App This application requires special Yellow Jacket R bluetooth pressure and temperature sensing devices For each bluetooth device being used the initial pairing with this mobile device must be done using the bluetooth settings utility After the one time initial pairing simply turn the bluetooth devices on and start a session below Start Session Service History If you have not already downloaded the Yellow Jacket ManTooth RSA Pressure Temperature App go to either the Apple App Store or the Google Play Store now to download the free app You can either use the QR code links that are on your ManTooth PT Module packaging follow the links that are available on YellowJacket com or just search for Yellow Jacket ManTooth in either app store General Settings The General Settings menu is where you can set up and change various functions of your ManTooth RSA app to personalize it for your specific needs To access the general settings on the
7. Session History section on the app s home screen Any saved service data can be emailed from within Session History Other Buttons At the bottom of the readings screen there are two additional buttons The first is labeled Clear readings This will clear the minimum maximum and average readings of the session This function is especially useful for determining system stability The other option is Exit Session This will not only exit the readings screen but will take you 12 all the way back to the home screen of the ManTooth RSA app ManTooth PT Module ManTooth PT Module q gt 6 7 8 IO 1 Status Light 2 Power Button 3 Device Name 4 Temperature Probe Indicators 5 Micro USB charging port 6 inch flare fitting pressure transducer connection 7 inch flare fitting with Schrader core pressure transducer connection 8 ManTooth thermistor temperature clamp 9 Temperature probe jacks Note On 67002 tethered units numbers 1 4 5 and 9 are on the main unit only The tethered unit is only equipped with the flair fittings for measuring refrigerant pressure and adjusting charge Status Light The multi colored LED indicates the status of your ManTooth PT Module Blinking Blue The module is on and searching for a Bluetooth connection This will continue from when you turn on your MantTooth PT Module until you connect to it within the ManTooth RSA Pressure Temperature
8. Setting the elevation will enable your ManTooth RSA app to correct for elevation pressure variations allowing for more accurate pressure readings You may either use your phone or tablet s built in GPS to determine your elevation or input the elevation manually by taping on the elevation and entering your elevation above sea level in feet Note Use GPS to Find Location functionality may not work on all devices especially those without cellular service Set Refrigerant To set the refrigerant for the current session tap on Refrigerant then scroll through the list of almost 100 NIST refrigerants and select the refrigerant corresponding to the unit you will be servicing If you accidently select an incorrect refrigerant do not worry you can also change the refrigerant later in the readings screen Setting a refrigerant is mandatory before moving to the next screen Refrigerants classified as flammable are in red text If such refrigerants are selected the operator may need additional certifications and or training Consult your local government and legal authority and comply fully with all requirements KK K K OK OK K OK K K OK OK K OK K K K OK K K K K K K K K K K K K K K K K K K K KK Set Location Details If you want to organize your saved data in session history you can enter the location information for the current service session This information will show up in the service reports you can email and is how the ser
9. app Note If your ManTooth PT Module looses connection to your phone or tablet it will automatically revert back to this searching for a connection mode Solid Blue The module is on and connected to a phone or tablet via Bluetooth Solid Green The module is connected to a power source via the Micro USB port and is charging Note once the unit is fully charged the green light will turn off Blinking Red Short The module will blink short flashes of red to indicate that it is sending data to a connected device This will occur while the light is solid blue Blinking Red Long The module will flash long blinks of red when the battery level is below 10 of total life remaining Power Button To turn your ManTooth PT Module on or off push and release the power button once 13 Device Name Your ManTooth PT Module s name is displayed right on the label for easy reference The name takes the form of YJPT XXXX XXXX The device name serves as your ManTooth PT Module s name within the ManTooth RSA app its serial number as well as its Bluetooth name that will appear on your phone or tablet when pairing Temperature Probe Indicator On the label of the ManTooth PT Module T1 and T2 are printed onto the label to indicate which temperature port on the back of the device corresponds to temperature port 1 T1 and temperature port 2 T2 Micro USB Charging Port The ManTooth PT Module is designed to be charged usin
10. ce or locate the nearest YELLOW JACKET distributor Corporate Office and Mailing Address Ritchie Engineering Co Inc YELLOW JACKET Products Division 10950 Hampshire Avenue South Bloomington MN 55438 2623 U S A Phone 952 943 1300 or 800 769 8370 Fax 800 769 8370 E mail custserv yellowjacket com www yellowjacket com Safety Information Use the instrument only as specified in this manual Otherwise the protection provided by the instrument may be impaired Refer to the safety information j A Warning identifies conditions and actions that pose hazards to the user A Caution f identifies conditions and actions that may damage the instrument or the equipment under test Warning To avoid personal injury or death follow these guidelines e Most governments and legal authorities require that HVAC technicians be trained and certified in the safe and proper operation of HVAC tools such as this instrument Since this tool may be connected to many types of equipment through a limitless combination of hoses and fittings proper training is the most important element of using this tool safely Read the entire Users Manual before using the instrument Use the instrument only as described in this Users Manual otherwise the protection provided by the equipment may be impaired Do not use the instrument if it is damaged Before you use the instrument inspect the case Look for cracks or loose components T
11. ct An Accessory popup SELECT FROM CONNECTED DEVICES YJPT 1415 0003 Tap on the ManTooth PT Module s that you wish to connect to your session from the list of devices that are displayed Remember your Module s name is the serial number printed on the main label and should take the form of YJPT XXXX XXXX Next tap the save icon in the upper right corner of the screen to save the module s to the session Note On iOS devices you must tap on Connect a Device to first connect your device to your phone or tablet and then select it under the Select From Connected Devices heading to fully connect it to your session Note to connect to your ManTooth PT Module s your module s must be on and searching for a connection where the blue light is blinking Assign Devices and Zero Assign detected devices YJPT 1415 0003 gt Before zeroing a pressure be sure the pressure transducer is not attached to the system Pressure Readings 0 0 psig YJPT 1415 0003 1 0 0 psig YJPT 1415 0003 2 Zero Zero Exit After you save your module s to the session they will be displayed at the top of the screen under Assign Detected Devices The pressures from the connected module s will be displayed at the bottom of the screen To zero the pressure transducer readings tap on Zero next to the corresponding pressure Note It is recommended that you zero the pressure transducer s at the beginning of each ne
12. fects for a period of two years All other YELLOW JACKET products included in this package are guaranteed to be free from material and workmanship defects for a period of one year These guarantees do not cover prod ucts that have been altered abused misused or improperly maintained Not all catalogued products are stocked and eli gible for return Please check with your YELLOW JACKET representative or the factory for more information All returns must have an RGA number and proof of purchase copy of invoice Please obtain an RGA number from Ritchie Engineering Customer Service by calling 800 769 8370 All returns must be pre paid y YELLOW JACKET Ritchie Engineering Co Inc YELLOW JACKET Products Division 10950 Hampshire Avenue South Bloomington MN 55438 U S A Phone 800 769 8370 or 952 943 1333 Fax 800 322 8684 E mail custserv yellowjacket com Web www yellowjacket com 2014 Ritchie Engineering Co Inc
13. g any standard Micro USB charging cord and corrisponding USB charger Inch Flare Fitting Pressure Transducer Connection The flare fitting on the front of the ManTooth PT Module directs to the pressure transducer with a working pressure range of 0 700 psia The fitting is equipped with an Adjust a Valve opener and sized to fit most system access ports for easy access to most AC and refrigeration units The compact size of the ManTooth PT Module and no hose connection system reduces charge loss that can occur from hoses used in charging through a standard test and charge manifold Adapters to connect the ManTooth PT Module to other size access ports are available from Yellow Jacket Inch Flare Fitting With Schrader Core Pressure Transducer Connection The Schrader core fitting on the ManTooth PT Module allows for recovering refrigerant adding charge or removing charge all without disconnecting your ManTooth PT Module from Temperature the system Display Resolution ManTooth Thermistor Clamp Temperature 0 2 C 0 36 F The thermistor pipe clamp probe is capable of Accuracy clamping to and measuring the temperature of Instrument pipes ranging in size from inch to 1 inches Working 4 F to 160 F Limited by The probe is capable of measuring with an Temperature battery accuracy of 0 2 C from 0 C to 70 C with a full Storage A F to 160 F range of 40 C to 130 C For best long term Tem
14. h that equipment will also deleted Deleted equipment and associated screen shots can not be retrieved Preferences Temperature Preference Set the units that the temperature readings from the temperature sensors Vapor Saturation Liquid Saturation and the values for Superheating and Subcooling are displayed in Options are degrees Fahrenheit F or degrees Celsius C Default temperature units are degrees Fahrenheit F Pressure Preference Set the units that the pressure readings are displayed in Available units are bar pounds per square inch absolute psia pounds per square inch gauge psig kilopascals kPa Megapascals MPa and kilogram per square centimeter kg cm 2 The default pressure units are pounds per square inch gage psig Auto Sleep This option will disable your phone or tablet s automatic sleep function so that while you are in a session taking readings your phone or tablet will not automatically go to sleep which could disrupt your session and readings The default auto sleep setting is Override Auto Sleep Off Device Management Power Down Connected Devices This is another way of shutting off your connected ManTooth PT Module s if you are not near enough to your module s to press the power button s and want to turn the power completely off Calibrate Device Readings This gives you the option to adjust the calibration of your ManTooth PT Module s pressure readings or tem
15. he instrument contains no internal user serviceable parts Do not open the instrument Have the instrument serviced only by Ritchie Engineering Co or authorized service centers Do not use the instrument if it operates abnormally Protection may be impaired When in doubt have the instrument serviced Do not operate the instrument around explosive gas vapor or dust Various refrigerants have been intentionally excluded for very significant safety reasons Never use refrigerants in this instrument that are not listed in the Set up menu The refrigerant database in this unit may include refrigerants classified as flammable If such refrigerants are selected the operator may need additional certifications and or training Consult your government and legal authority and comply fully with all requirements Always wear eye and skin protection when working with refrigerants Escaping refrigerant vapors will present a freezing danger Do not direct refrigerant vapors venting from hoses towards the skin e Maximum Working Pressure 700 psia 4 83 MPa e Because this instrument allows for various inputs including electrical and mechanical care must be taken to observe any ways that an electrical shock hazard could develop Example Wet or humid conditions along with a sensor could allow an electrical path across the instrument Keep all interconnected equipment clean organized and in proper condition Do not use the in
16. it 3 35PM Jun 18 2014 READING 3 36PM Jun 18 2014 READING In service history you are able to browse through data that was saved during previous service sessions Saved data is organized alphabetically by location then by each location s equipment finally by date and time the data was taken If you tap on the desired service history reading you can see the reading that was taken and either email the reading to someone or delete it Remember once you have deleted a reading it can not be retrieved Start Session ManTooth RSA tt Pressure Temperature App This application requires special Yellow Jacket R bluetooth pressure and temperature sensing devices For each bluetooth device being used the initial pairing with this mobile device must be done using the bluetooth settings utility After the one time initial pairing simply turn the bluetooth devices on and start a session below Start Session Service History Sessions are where you connect your phone or tablet with your ManTooth PT Module to see and collect system readings To begin a new session tap on Start Session in the App home screen Session Settings Set elevation 0 Use GPS to Find Elevation Set refrigerant Set location details Using the correct settings that are specific for the current system you are servicing will ensure the best possible pressure readings as well as liquid and vapor saturation values Set Elevation
17. me To pair your ManTooth PT Module you first need to open the settings menu on the phone or tablet you wish to pair to your ManTooth PT Module Next tap on Bluetooth to enter the Bluetooth settings Be sure to turn your phone or tablet s Bluetooth radio on if it is not already on Apple iOS Android Settings 6 Settings Wireless and network Airplane Mode gt Wi Fi a Wi Fi Ba Bluetooth gt Bluetooth ma Data usage Cellular Personal Hotspot More settings Device Home screen mode Notification Center Control Center Do Not Disturb Blocking mode w Sound D a Display Next turn your ManTooth PT Module on by pressing and releasing the power button on the main module If you have a 67002 dual unit the main module is the one that says ManTooth PT Module on the label not the one that says ManTooth PT Tether Module The module will go through a brief start up sequence then the light on your ManTooth PT Module should start to blink blue This means that your ManTooth PT Module is searching for available Bluetooth devices to connect with Next if you are using an Android phone or tablet tap on Scan at the bottom of the screen to scan for available devices Apple iOS devices should automatically scan for available Bluetooth devices Apple iOS Android lt Bluetooth My device lt Settings Bluetooth SAMSUNG SGH 1747 Bluetooth DEVICES Available device
18. perature For best battery performance Stability of your thermistor pipe clamp probe do not store at over 100 F avoid storing it at temperatures exceeding 75 C Working O to 95 RH non condensing 167 F humidity IP Class IP nn Thermistor Probe Jacks Battery Life 10 hours continuous Each ManTooth PT Module is equipped with 2 Range Up to 400 feet temperature probe jacks for use with Limited by Phone or Tablet ManTooth Thermistor Clamps Bluetooth radio strength Note As with any radio technology when you start to add obstructions between the transmitter and the receiver the ultimate range may decrease as Instrumentation Specification different objects interfere with the radio 7 signal in different ways The more Pressure 0 1 psi 0 1 bar 1 kPa 0 01 obstructions you add between the phone nsin MPa 0 01 kg cm 2 and the ManTooth the weaker the signal one 8 may become after it has passed through Resolution or around the obstacles This could 0 o ultimately lead to a shorter maximum PieSsUre 0 5 of full scale at 25 C range The ManTooth utilizes the highest sensing 1 of full scale 55 F to 130 F Bluetooth radio transmitter signal o AN o strength available to ensure the best Acu aey 2 of full scale 40 F to 248 F possible range of your ManTooth however Working O to 700 psia 48 3 bar each situation will be slightly different depending on the environment Pressure surroundings within you are working
19. perature readings away from the factory defaults Restore Factory Defaults This will clear any calibration adjustments that have been done on the ManTooth PT Module since it left the factory Auto Off This slider gives you the option of having your ManTooth PT Module automatically turn itself off after a designated period of time It can be set anywhere from 1 to 90 minutes After the ManTooth PT Module has been connected for the specified auto off time an alert will pop up asking if you would like to reset the auto off timer if you wish to reset the timer simply tap anywhere on the screen Also included is an auto off never setting Moving the slider all the way to the left will set the auto off timer to never Default is Auto Off 5 min Getting Back to the Previous Screen To return to the previous screen from the one you are currently viewing tap on the icon in the upper left hand corner This function is the same in all of the screens in the ManTooth RSA App Service History ManTooth RSA Pressure Temperature App This application requires special Yellow Jacket R bluetooth pressure and temperature sensing devices For each bluetooth device being used the initial pairing with this mobile device must be done using the bluetooth settings utility After the one time initial pairing simply turn the bluetooth devices on and start a session below Start Session Service History Ritchie Bldg2 Window Un
20. s Scanning Santa Fe Sport N Mee A YJPT 1415 0003 YJPT 1415 0003 O YJPT 1415 0001 O YJPT 1418 0004 Q YJPT 14240001 00 A0 96 3B D0 C4 Your ManTooth PT Module should then show up as an available device to pair with on your phone or tablet s screen This may take up to 30 seconds Note Your ManTooth PT Module s name is the same as the serial number and is printed on the main module s label just above the model number 67001 or 67002 Once your ManTooth PT Module shows up as an available device tap on it s name to pair it with your phone On Android systems a Bluetooth pairing request alert may pop up asking to confirm the passkey tap on OK to continue Android Bluetooth pairing request Confirm passkey is 526096 to pair with YJPT 1415 0003 Cancel OK After pairing your Apple iOS phone or tablet to your ManTooth PT Module it should show up as either Connected or Not Connected rather than Not Paired on the Bluetooth settings screen On Android devices under the Paired devices section on the Bluetooth settings screen Apple iOS Android lt O Bluetooth My device g SAMSUNG SGH 1747 lt Settings Bluetooth Bluetooth Paired devices a YJPT 1415 0003 DEVICES Santa Fe Sport N ected i Available devices YJPT 1415 0003 O YJPT 1415 0001 Now Discoverable O YJPT 1418 0004 O YJPT 14240001 00 A0 96 3B D0 C4
21. ss 1 Bluetooth v 2 1 radio The ManTooth PT Module is compatible with any iOS device running iOS 7 0 or later and Android devices running Android 4 0 3 Ice Cream Sandwich or later Before you use your ManTooth PT Module for the first time you should make sure that it is fully charged You will also need to download the free ManTooth RSA Pressure Temperature App from the Apple App Store for iOS devices or the Google Play store for Android devices You can either use the QR code links that are on your ManTooth PT Module packaging follow the links that are available on YellowJacket com or just search for Yellow Jacket ManTooth in either app store Pairing To display service readings your ManTooth PT Module must be connected via Bluetooth to an iOS phone or tablet running iOS 7 0 or an Android phone or tablet running Android 4 0 3 Ice Cream Sandwich or later To connect your ManTooth PT Module to your phone or tablet the two must first be paired to one another The pairing of the module to your device is done in your phone or tablet s settings Note you only need to pair your ManTooth PT Module the first time you connect it to your phone or tablet however if you force your phone or tablet to forget your ManTooth PT Module you will need to re pair Note your ManTooth PT Module can be paired with multiple devices at the same time However it can only be connected and sending readings to one phone or tablet at a ti
22. strument if you are not qualified to recognize potential electrical faults Caution To avoid damage to equipment follow these guidelines e Do not allow pressures beyond the specifications listed in this manual e Do not attempt to introduce liquid or samples heavily laden with oil into the instrument e Read and observe instructions and specifications related to the batteries used in this instrument that may cause damage to it e Do not use this instrument on systems containing leak sealing chemicals These leak sealants can collect and harden in the instrument causing permanent damage e Only use this instrument with the protective boot in place as this protects the charging port and temperature probe connection ports from unwanted contaminants e Do not use damaged USB chargers to recharge the ManTooth PT Module as this could damage the circuitry and or battery e Only use with refrigerants approved for use with the ManTooth PT Module Use of unapproved refrigerants may cause damage to the ManTooth PT Module A complete list of approved refrigerants can be found in the ManTooth RSA app in the Select Refrigerant option Getting Started The ManTooth PT Module is a precise instrument to accurately measure and report the critical information needed to service refrigeration and air conditioning equipment The ManTooth PT Module reports the system information directly to your smartphone or tablet by means of a cla
23. vice history will be organized Here you have the ability to either add a new location or select an existing location Once you have designated a location you can also designate what equipment is being serviced during the session Locations can have multiple pieces of equipment associated with them so you can keep track of each individual unit at locations that may have more than one system Saved session data will be saved to Session History in the app s main menu and sorted first alphabetically by business name or customer last name then alphabetically by assigned equipment name and lastly by the date and time the data was saved Note Location details are optional Any saved session data without an assigned location will be saved under No Location and appear at the end of the Service History list The No Location data will be sorted simply by date and time You can not assign a location to data at a later time Assign Devices and Zero Sma Exit Assign Detected Devices Now you are ready to connect your ManTooth PT Module to your current session To connect your module first tap on Devices None Specified this will take you to the next screen Apple iOS Android YJPT 1415 0003 You must connect to each ManTooth device separately every time you turn them on Once connected they will appear on the list below for you to use in this session Please allow 5 10 seconds for devices to appear in the Sele
24. w session before connecting your ManTooth PT Module to a system This will ensure the most accurate device readings Attach Devices Attach Devices Pressure Readings 0 0 psig YJPT 1415 0003 1 0 0 psig YJPT 1415 0003 2 Attach the pressure transducers and temperature probes to the system then select Begin Session 10 Before starting the session you have one more chance to check to make sure that the pressure transducers are zeroed While in the Attach Devices screen is the appropriate time to connect your ManTooth PT Module to your system Connecting the ManTooth PT Module to the system before beginning your session will also ensure that the average minimum and maximum readings are accurate Readings The readings screen will display the pressures and temperatures as measured by the ManTooth PT Module display the liquid and vapor saturation values as well as calculate and display the superheat and subcooling values The first time you connect your ManTooth PT Module to a new phone or tablet you will have to assign the pressure transducers and temperature sensors These assignments are not permanent and can be changed at anytime Note the pressure transducer in every ManTooth PT Module main or tethered is capable of accurately reading pressures up to 700 psia 48 3 bar and therefore can reliably be used on either the high or low side Readings Low Pressure High Pressure UNASSIGNED min

Download Pdf Manuals