1. AAPS User s Manual 906 0005 Cody Browne 10 06 2014 APC Firmware 09 19 2014 APB Firmware 07 11 2014 906 0005 AAPS Users Manual Rev D docx Dick Campbell Company 2014 All rights reserved Page 3 of 20 Campbell Company AAPS User s Manual 1 Table of Contents 1 lee 4 2 Idee Velo BEE 5 2 1 Bee IER Re e EE e 5 2 2 ADDITIONAL INFORMATION sscssccosscassemsceassncamecesecieuncaaseradaranatunaranecianecasecadatatatamatetatenatecanenadatatoatetedaty 5 2S CONTAC TINF FORUA TON WEE 5 3 CON VIE WE eege 6 3 1 PRODUCE TT 6 3 2 EE 6 Oia GOMBONENT E 7 SS ME ele TE 7 4 Oy SUS COP tel Lee e EE oua E ESEN 8 4 1 ACCESSINGTREWEPPACE ila 8 4 2 VERS PR AR 8 GE SET lee e 9 5 Ree leif OU Le D 17 5 1 APC TROUBLESHOOTING rn aaa aa taaaa a tataataaaastaoaastataestaneestsoeestaseesrassessasaessaooos 17 5 2 RUNNING A PATCH ME 18 5 3 APB TpOUpLESHOOTING eee 18 6 Appendix A Acronyms Abbreviations amp Definitions 20 906 0005 AAPS Users Manual Rev D docx Page 4 of 20 Dick Campbell Company 2014 All rights reserved 2 2 1 Campbell Company AAPS User s Manual Introduction Purpose of this Document The purpose of the document is to describe the operation of the Advisor Advanced Pedestrian System AAPS This document doesn t cover the installation of the AAPS 2 2 2 3 Additional Information See the AAPS Installation Guide for installation instructions Reference the Campbell Company In
2. 0 0 BSON v1 2 2 0 3 0 0 Intersection Interface 120V I O 120V VO Figure 5 a The check boxes at the beginning signify what stations are active To adda station click the checkbox and it will add more stations to the system figure 6 Black means checked white means unchecked b AAPS mode 4 options Off Default EP APS and Identify figure 6 i Off behaves like a typical button places calls no Audio li Default is normal APS operation iii EP APS only actuates APS audio when an extended press is placed iv Identify will put the APB s into a mode where their LED s will blink the assigned station ID troubleshooting c Extra press mode places two calls to the traffic controller one for current cycle and one for following cycle d Vib Call Pulse Allows for vibrotactile feedback when the button is pressed e Auto Recall When checked constant calls will occur if a button is at ATTN f Audio Countdown When checked audible countdown will be enabled 906 0005 AAPS Users Manual Rev D docx Dick Campbell Company 2014 All rights reserved Page 9 of 20 Campbell Company AAPS User s Manual Q h 4 3 2 Locator AGC When checked locator AGC will be enabled If un checked locator tone will be constant Clearance mode 5 options Off no Beaconing Ping Pong Dest Init beaconing and Audible countdown i Destination beaconing implements beaconing only the destination APB will beacon in the clearance phas
3. In addition to different form factors the stations are available in a wide La Kee range of colors DEE REMANIO Sting 3 4 Audio Messages The AAPS comes fully programmed with audio files from the factory but we give you the option to create your own custom messages ina simple wav format that can be easily uploaded via the APC network connection Second languages gender narrative and special percussive tones can be easily created and uploaded Figure 1 Base Station 906 0005 AAPS Users Manual Rev D docx Dick Campbell Company 2014 All rights reserved Page 7 of 20 Campbell Company AAPS User s Manual System Configuration 4 1 Accessing the Webpage To make changes and view the AAPS webpage simply plug an Ethernet cable into the Ethernet port on the front of the APC Then connect the Ethernet cable into your laptop Start up a web browser such as Google Chrome and type in the IP 192 168 1 101 into the address bar See Below New Tab C fi 192 168 1 101 Figure 2 Webpage Address bar You will see the following screen pop up looking for credentials Default user name admin Password password Username Password Login Figure 3 Authentication Page 4 2 Main Screen The first screen is shown below it gives the status of the pedestrian system figure 5 To view this screen click Here to enable real time status Location Intersection The Pedestrian Signal Status shows the state of the S
4. 5 17 2012 11 09 AM Application 320 KB EP putty 5 24 2010 2 00 PM Applicaton 444 KB README 9 1 2010 5 05 PM Text Document LKB a Updaterste patch 6 25 201212 25PM PATCH File I KB gap 5 24 2010 2 29PM Application 132 KB Figure 18 Patch 5 3 APB Troubleshooting When troubleshooting button problems first start by bringing up the APC s webpage Refer to the Station tab figure 7 above 5 3 1 APB Communication issues 1 First check voltage on the APB Should be 16 18 VAC a If Voltage is at 4 VAC the fuse has tripped b If Voltage is at O VAC it is possible lightning has destroyed the termination board fusing Check for short Warning this may cause APC to shut off 906 0005 AAPS Users Manual Rev D docx Page 18 of 20 Dick Campbell Company 2014 All rights reserved Campbell Company AAPS User s Manual c Power cycle and check voltage lf fuse trips again disconnect button and power cycle Voltage correct 1 Yes gt Replace button 2 NoDOhm wiring for shorts 2 If APB is not communicating you will see ATTN and a red light next the station number Start up the station tab on the APC 3 If the station that has lost communication is station 1 then the first step would be to try changing the station number Set up the Change Station ID to the figure shown below and click change If the button s ID is zero it will come back up in 15 seconds 4 Ifan error button not found is displayed go to the System tab and uncheck the statio
5. Advisor Advanced Pedestrian System AAPS User s Manual 906 0005 Version D e October 13 2014 Campbell Company AAPS User s Manual CAMPBELL COMPANY AP IIs Campbell Company 450 W McGregor Drive Boise Idaho 83702 USA Tel 1 208 345 7459 Fax 1 208 345 7481 Last edited 13 October 2014 This document is copyright 13 October 2014 by Dick Campbell Company All rights reserved No part of this publication may be reproduced transmitted transcribed stored in a retrieval system or translated into any language in any form or by any means electronic mechanical photocopying recording or otherwise without prior written permission from Campbell Company All copyright confidential information patents design rights and all other intellectual property rights of whatsoever nature contained herein are and shall remain the sole and exclusive property of Campbell Company The information furnished herein is believed to be accurate and reliable However no responsibility is assumed by Campbell Company for its use or for any infringements of patents or other rights of third parties resulting from its use The Dick Campbell Company name and Campbell Company logo are trademarks or registered trademarks of Campbell Company All other trademarks are the property of their respective owners 906 0005 AAPS Users Manual Rev D docx Page 2 of 20 Dick Campbell Company 2014 All rights reserved Campbell Company AAPS User s Manual
6. a DHCP None None v IP Address 192 168 42 123 192 168 42 123 Netmask 255 255 2550 255 255 255 0 Gateway 192 168 42 1 192 168 42 1 Broadcast 192 168 42 255 192 168 42 255 DNS Server 8 8 8 8 3 8 8 8 Ping Destination Figure 9 Network Tab T 8 4 3 5 Setting the Time The Time tab is used for setting up the Real Time clock There are two ways of setting the time a NTP enable or getting the time from the internet Note the APC must be able to access to the network and an IP address must be entered in the NTP server box b The time can be set by clicking Submit Time configuration or the Day Month and Year can be manually entered Once the time options are chosen click Submit Time configuration Status System Station Sound Files Time Network f Log Files f APC Links Advanced Log out Submiting the time will log you out of the webpage A normal reboot is required to save the time to the battery backed clock Time Configuration Current Value New Value Time January 4th 2000 11 35 22 Januay vi 4 vi 2013 11 v 36 v 22 v America Boise Figure 10 Time Tab 906 0005 AAPS Users Manual Rev D docx Dick Campbell Company 2014 All rights reserved Page 13 of 20 Campbell Company AAPS User s Manual 4 3 6 Viewing Log Files There are three sets of logs to be viewed APB log Event log and System log Pedcall log reports ped call counts by hour by day Event log
7. all Output BCEE a a a a a a Kl a Figure 14 8 Ped Closure Dwell Time in ms the contacts will closed to the traffic controller to signify a normal press was made 9 APS Closure Dwell Time in ms the contacts will closed to the traffic controller to signify an extended press was made Any changes to the advanced configuration should only be done at the direction of Campbell Company 10 CID scan rate How often the I O is read 11 APB update rate How often the buttons receive an update 12 Display Update rate How often the Front panel display is updated 13 Display timeout Time before the front panel display times out shuts off 14 Countdown Number How many audible numbers to send to stations 15 APB Timeout tuning parameter Sets time to display a station as ATTN 16 Wire map The wire mapping can be changed a Walk input Able to choose what phases are assigned to what pins by color code D Don t walk Input Able to choose what phases are assigned to what pins by color code c Call output Able to choose what Pin wire will place a call on a certain phase 906 0005 AAPS Users Manual Rev D docx Page 16 of 20 Dick Campbell Company 2014 All rights reserved Campbell Company AAPS User s Manual s Troubleshooting The following chapter discusses troubleshooting the AAPS system in three parts APC Running Patches and APB 5 1 APC Troubleshooting 1 Check Status light on front pa
8. atic Gain Control AGC available for all audio messages e Accepts any audio message in WAV format 906 0005 AAPS Users Manual Rev D docx Page 6 of 20 Dick Campbell Company 2014 All rights reserved Campbell Company AAPS User s Manual e Audio messages and station configuration backed up on the APC enables quick recovery after a station knock down e Clearance interval options including beaconing and audible countdown e Preemption options available 3 3 Components There are three primary components to the AAPS the Advanced Pedestrian Controller a Termination Board and one or more Advanced Pedestrian Button APB The APC is the center point of the AAPS It provides both power and pedestrian signal information to all of the APBs The APC is also the point at which the system is configured The APC is located in the traffic controller cabinet It connects to the 120VAC load switch outputs for the pedestrian signals and the low voltage pedestrian call inputs The Termination Board is located in the traffic controller cabinet with the APC It provides a convenient place to land all of the field connections to the APBs The Termination also provides current protection to each field connection individually The APB is the point of interaction with the pedestrian The APB is available in several form factors including e Base Station A fully integrated pedestrian station e 400 A A station designed to drop into a 400 style frame si DON T
9. e li Initiation beaconing implements beaconing at the initiation station only Night mode Check the box to enable and then set the time for the hours that you would like to adjust the volume differently AGC responsiveness Adjusts how quickly the ambient gain responds 1 20 20 least responsive Walk message Timeout Refers to a rest in walk situation adjusts the time the walk message will timeout without being interrupted by the flashing don t walk Extended press time Adjusts the length time required to place an extended press or APS call Repeated Acknowledgement Number of seconds between each repeated acknowledgement message 0 means no repeat Submit system Configuration button will submit all changes to APC must be pressed once all settings are made Note this only saves settings To update buttons go to the station tab and click send all settings Changing Station Settings The most common changes will have to do with the Station tab Shown Below Page 10 of 20 906 0005 AAPS Users Manual Rev D docx Dick Campbell Company 2014 All rights reserved Campbell Company AAPS User s Manual Status Station ESTE gle BRUCH Bete ee falli KONN Ce aC ante Molo Roli Station Confiquration 4 a 6 7 8 3 v v 2 2 I 2 Prese Jen fer som far fe Send to station 1 2 4 5 7 8 d 6 Remote Cal Sona Sona Sena Sena Sena Saa see Se Station ID Old Station ID New v New Statio
10. ging reports any conflicts and or loss of station communication System logging reports changes made to the system status System Station Sound Files Naina Log Files Isi Ete Uecht System Log Event Log APB Log Figure 11 Log File tab 4 3 7 Configuring the APC Link Tab APC links tab will keep track of all the APC s on the network on one APC 1 Make sure the network APC is viewable on the network 2 Entera Name or the location of the network APC 3 Type in https in the URL box then the IP address of the network APC a Example http 192 168 1 101 4 Click Add 5 Click the new link to make sure it links to the network APC Seu ESE Len Re 0 eRe ZA RU Mi at lone fraa ss APC Links RATE le g aE Keii Name URL APC DW Add Figure 12 906 0005 AAPS Users Manual Rev D docx Page 14 of 20 Dick Campbell Company 2014 All rights reserved Campbell Company AAPS User s Manual 4 3 8 Configuring the Advanced Tab Status ice Station Sound Files f Time Network Ueleg OH Advanced Log out Configuration File New Configuration File Choose File No file chosen Current Configuration File Configuration file Reboot Logging Options Reset APB Log Reset APB Log User Management Access Usemame Real Name Level Create user Intersection Identification Location Location Intersection Intersection CCH 1 PO Info PO XXX Intersection Image Choose File No fi
11. ignal DW FDW W and if a call has been placed Stations Status bar will show a state of the stations The Status tab gives an overview of the system The System tab allows for global settings to be adjusted The Station tab allows for individual station settings to be adjusted The Sound tab allows for audio files to be changed The Network tab allows for changes to the APC IP address The Time tab allows for the time to be adjusted 906 0005 AAPS Users Manual Rev D docx Page 8 of 20 Dick Campbell Company 2014 All rights reserved Campbell Company AAPS User s Manual The Log Files tab is where log files are located The APC Links tab allows for all APC s IP addresses to be stored The Advanced tab is where advanced settings can be found Log out tab logs you out of the system 4 3 Making Changes 4 3 1 system Changes System Tab This tab is where changes are made to the entire system DI E E E I E E 8 COOC OO 11 12 13 14 15 16 System Configuration Current Value NIAVAVEUTE Cee a o Co D cl we O A ce E Night Mode Start Hour 20 20 v Night Mode Start Minute 0 0 v Night Mode End Minute 0 Dr Clearance Mode Audible Countdown Audible Countdown e AGC Responsiveness 5 v Walk Timeout 10 10 v This must be greater than the actuall walk time for clearance options other than Nothing to work Extended Press Time 1 1 v v Repeated Acknowledgement 0 APB Protocol BSON V1 2 2 0 3
12. ion that contains the Mico controller push button speaker adapter plate Any portion of a roadway at an intersection or elsewhere distinctly Crosswalk indicated for pedestrian crossing by lines of other marking on the come surface MUTCD Night Mode Ability to change audio volumes by time of day Pedestrian Signal Designation 906 0005 AAPS Users Manual Rev D docx Page 20 of 20 Dick Campbell Company 2014 All rights reserved
13. it can be found An extended press provides specific intersection information and access to additional functions The audible walk tone or message is accompanied by a vibro tactile indication during the visual walk display Optional clearance phase indications may provide additional information to the pedestrian where appropriate Each AAPS is pre configured at the factory based on the documentation provided by the customer Configuring the AAPS can be done entirely though the APC management webpage so the customer can re configure the system as needed Campbell Company cannot guarantee the AAPS will work properly with all existing field wiring especially if a single common to the buttons and signal lighting is shared Each case will have to be tried and proven because it depends on the condition of the wires splices etc In the event there are no field wires AAPS can be swapped out for an alternative as long as there is no damage to the AAPS units 3 2 Features e Capable of using existing pedestrian field wiring to provide power and communication to the push button stations reducing costs in retrofit installations e Ethernet access for remote communication e All configurable settings available over network via webpage including audio message upload e Time of day functions including night time audio volumes e Pedestrian call count data e Independent volumes for locator and non locator audio messages e Station independent volumes e Autom
14. ke sure IP has the first same three octets 192 168 1 and the last octet is not the same as the APC s 101 OR that it is not 255 or 1 b Type the APC s address in web browser ie 192 168 1 101 c If no connection check for LED on computer s Ethernet port i Also can try pinging APC li Open Command prompt type cmd in the search bar and hit enter ili Type ping 192 168 1 101 then Enter iv The APC will reply if the computer IP is configured properly da Running a Patch Open 1 Make sure there is communication with the APC see above a dani 2 Download patch folder and Extract All right click and choose 7 Permanently shred with AVG the option below S sn dit with Notepad 3 Open patch folder the unzipped one and open the ips text es document Move to Dropbox i Add the IP address of the APC unit in the ips renn text doc and save Ee 4 Double click on patch windows batch file Sg 5 Click yes to any warnings PE 6 Once the patch is done it will say Press any key to continue Copy Figure 17 Extracting Patch Name Date modified Type Size 4 getovtput psftp 5 17 2012 11 20AM PSFTP File i KB DW 9 26 2011 4 30 PM Text Document 1 K new updaterate patch 6 25 2012 10 31 AM PATCH File 91 KB Gi patch 6 25 2012 10 36 AM Windows Batch File 1 KB patch putty 6 25 2012 12 47 PM PUTTY File LKE prepatch psftp 6 25 2012 10 38 AM PSFTP File 1 KB oP picp 4 2 20123 50 PM Application 308 KB EP psttp
15. le chosen If no file is selected the map will not be changed APC Info View Syslog View Boot Log View EoP status Figure 13 1 Configuration file is able to be uploaded to the APC Older versions may not work 2 Reboot button will do a software reboot Must be done to set time and IP address for the APC 3 Reset APB log This will clear the button log files 4 Additional users can be created a Change password click on edit user Will reset the password on the AAPS webpage Remember what you changed it to Mark it on Intersection Planning Sheet and store in cabinet Doc Sleeve 5 The intersection identification can be found here a Location Example Boise ID Intersection Example 1 at Main CCH order 1234 PO Intersection image can be selected here and then click Submit Intersection Identification to update APC 6 There are three additional logs that can be accessed Syslog bootlog EoP status 72900 906 0005 AAPS Users Manual Rev D docx Dick Campbell Company 2014 All rights reserved Page 15 of 20 Campbell Company AAPS User s Manual 7 APB Memory allows the user to wipe the button memory completely view files stored on the button and also view firmware figure 13 APB Memory 1 2 3 4 5 6 7 8 View Fi vow Cven von Ven view vin ina O REECH View Fare en ven view view vw Dm en I Advanced Configuration Current Value New Value Wire Map Phase Walk Input Dont Walk Input C
16. n that is not communicating Meaning remove the button from the system Then click submit changes 5 Wait for approximately 30 seconds 6 Ctrl r will refresh the page Next go back to the system tab and click the station back into the system Click Submit System Configuration 5 3 2 Calls placed on two phases 1 If one button press places calls on two phases check the 1 2 grouping Station Tab This usually means a grouped ge LEI Le 2 e a roup IC v 2 button is on an improper phase see O O 2 To fix simply change the grouping to be correct 3 Typically all buttons on a phase are grouped together ee eo eo on Figure 19 Station Settings 906 0005 AAPS Users Manual Rev D docx Dick Campbell Company 2014 All rights reserved Page 19 of 20 Campbell Company AAPS User s Manual 6 Appendix A Acronyms Abbreviations 8 Definitions Accessible A device that communicates information about pedestrian timing in a Pedestrian Signal non visual format such as audible tones verbal messages and or APS vibrating surfaces MUTCD A type of traffic control signal operation in which some or all signal Actuated operation ohases are operated on the basis of actuation MUTCD Use of sound source to provide directional orientation and alignment Audible Beaconing information Automatic Gain An APS volume control that is automatically responsive to ambient Control AGC background sound Fully integrated APS stat
17. n ID New v Figure 6 Station Tab All active stations will be shown in this tab To change the Signal phase of the button change the Phase number To change the group of the button change the Group number To change the volume level enter a number between 300 and 300 Defaults are shown above In order to make the changes permanent click Save APB Configuration to APC To save and send all settings to buttons click Save and Send All Settings Buttons with ID s can be changed back to new Simple change old station ID to be the ID of the button you want to be new leave New station ID at New and click Change ID 4 3 3 Changing Audio files The Sound File tab allows for audio files to be uploaded to individual stations a First add sound files to the file system Click Choose Files select them then click upload figure 6 b Next find the message that you will be changing the audio files on c Simply click on the dropdown box and select each audio file for each message on each station slot figure 7 d Click Send in the matrix figure 6 to send audio files to the ped stations 906 0005 AAPS Users Manual Rev D docx Dick Campbell Company 2014 All rights reserved Page 11 of 20 Campbell Company AAPS User s Manual 906 0005 AAPS Users Manual Rev D docx Page 12 of 20 a Message that is to be sent is on the left All messages button is one from the bottom Train Approaching Phil wa
18. nel of the APC RED and Green Both should be blinking RED at a fast speed signifying communication with the buttons and Green ata 1 2 second rate a If status light green has stopped blinking solid on off Contact Campbell Company for assistance re 1 Z Station 16 RRE e Do e sees e Figure 15 LED s Screen b Status screen showing buttons that are running up arrows and buttons that are not communicating down arrows 2 No Communication to APC a Check computer s IP address i Hold Windows key R and then type in cmd and hit enter 1 A prompt will appear figure 13 ES Administrator Command Prompt C Users Zane gt ipconf ig Vindows IP Configuration Wireless LAN adapter Wireless Network Connection Connection specific DNS Suffix pedsafety local Link Local IPv6 Address 3 Fe89 249c 344c 048a 7bbdx9 eee G nno so e EE elt dE Subnet Mask a a a m m fa e m n Se a 3 192 168 42 1 Ethernet adapter Local flrea Connection Connection specific DNS Suffix S ey ee 192 168 1 198 LEO nn RR wows ergett Nutk eli Sle SE a E 255 255 255 0 Default Gateway so Figure 16 Showing connection and IP address li Type ipconfig and hit Enter iii Look at local area connection 906 0005 AAPS Users Manual Rev D docx Dick Campbell Company 2014 All rights reserved Page 17 of 20 Campbell Company AAPS User s Manual iv Ma
19. tersection Worksheet for location specific information Set the AAPS Installation Quick Guide for a brief graphical installation guide See the Base Station Mounting Template for an easy to use hole pattern for mounting APBs Contact Information The first line of contact should be the distributor that the system was purchased from If you are unable to contact the distributor contact Campbell Company directly 906 0005 AAPS Users Manual Rev D docx Dick Campbell Company 2014 All rights reserved Page 5 of 20 Campbell Company AAPS User s Manual 3 1 Product Overview The AAPS is an Accessible Pedestrian Signal APS based on network communications Communication from the traffic controller cabinet to the pedestrian station is done over two conductors Power for the pedestrian stations is also provided on the same two conductors In many cases the two conductors are already at the intersection from the previous pedestrian system The AAPS uses a webpage based interface to manage and monitor the system This webpage can be viewed on any device with a network connection to the APC Desktop computers laptops and even handheld devices can connect and operate the system as long as they share a network connection The AAPS provides all of the standard features for an APS as defined by the MUTCD as well as additional features based on local specifications A locator tone tells a pedestrian that the crossing is equipped with APS and where
20. v gt m 0 00 Upload File Upload File Choose Files No file chosen Upload to APC Send to APB 8 All Stations eo am ronments se ss se e et Message DOSSO Er mei ee e sn e t Figure 7 Audio send Matrix Audio list Locator Station Selected File 1 Locator 880hz 100ms 60pct wav v 2 Locator 880hz 100ms 60pct wav v 3 Locator 880hz 100ms 60pct wav v 4 Locator 880hz 100ms 60pct wav v 5 Locator 880hz 100ms 60pct wav v 6 Locator 880hz 100ms 60pct wav v 7 Locator 880hz 100ms 60pct wav v 8 Locator 880hz 100ms 60pct wav v Acknowledgement Station Selected File 1 Wait Phil wav M 2 Wait Phil wav v 3 Wait Phil wav Y 4 Wait Phil wav v 5 Wait Phil wav v 6 Wait Phil wav v T Wait Phil wav v 8 Wait Phil wav v Figure 8 Setting up audio files Dick Campbell Company 2014 All rights reserved Campbell Company AAPS User s Manual 4 3 4 Changing APC IP In order to remotely communicate with the APC the IP address must be set up a Before changing settings consult you IT Department Also remember that the IP address is how access is granted to the webpage If the IP address is changed document tt SECM GG Kack icht Network ef 23 Eil cm Kle lose en mimeo nett The system must be rebooted for network changes to take effect Network Configuration Current Value New Value Hostname