Home
simcard sc-mb ethernet user manual
Contents
1. SC MMB0000 ADC SC MMB0000 IN1 SC MMB0000 IN2 Launch HW Test Double click on each Board a Screen 2 Mother Board A 1 4 0N 0FF SC MMB0000 With double click on the Mother A INPUTS OUTPUTS Board the user will be able to 10 90 10 20 330 410 090 50 10 9010100400050 observe 2 100 189 200 340 420 50 50 20100 180 6G 0902050050 The INPUTS state ON OFF 30 10 190 270 350 64 50 50 301010 70350005050 Activate or to deactivate an output 40 19 20 W 368 494 20 600 410 129 209 229 369 40 5209 00 pressing with the mouse on the 5 DO 210 20 30 159 50 69 50102101030 150 509600 number corresponding to the 6 140 20 200 HG 150 540 HO 5011020200 220 460 50 6020 OUTPUTS 10 159 239 350 WO VG 550 60 95923029 E7959 80 Do the test of the displays or check 89 169 20 VG WG 488 6G 643 80 169 40 229 WG 4809 509 64D the 5 analogical inputs or pots ALLON ALLOFF TEST ALL marking before the icon ACTIVATE ACTMATE ADC O poe en j i e aen ADCn n analogical input to activating deactivate Qer TEST DISPLAYS 04 USER MANUAL Ja SIMCARD SC MB ETHERNET MAN US E RR 10 007 35 User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators G www sismo soluciones com Sano SOLUCIONES Plug amp Fly Screen 3 Mother Board A 7 SC MMB0000 The following screen appears if the ORANE user presses with the mouse on ETE E TEST DISPLAYS aaa Press
2. 04 USER MANUAL SIMCARD SC MB ETHERNET MAN US E RR 10 007 30 User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators CO www sismo soluciones com Sano SOLUCIONES Plug amp Fly 1 Return to modify again some section in which the configuration has not been the required one by the user and later to save again the new information pressing with the mouse on SAVE BOARD CONFIG 2 Make a reset of the Mother Board It returns to the configuration by default It is made on having pressed with the mouse on RESTORE DEFAULT VALUES in the configuration page or pressing manually more than 10 seconds on RESET button placed physically on the Mother Board Ethernet To make this step the Board must be correctly connected to the power supply With both methods we make the erased EEPROM Electrically Erasable Programmable Read Only Memory RESET SC MMB0000 CONFIG PAGE NETWORK CONFIG N MAC ADDRESS 00 04A3 00 00 00 aes e im IP ADDRESS 192 1168 1 180 A z LOCAL PORT 1024 MASK 255 255 1285 0 z 1026 DEFAULT GATEWAY 192 168 1 1 iiciin _ SAVEBOARD CONFIG RESTORE DEFAULT VALUES 3 Finish the configuration of the Mother Board and begin with the configuration of the Daughters Boards Again and in order that it makes effect in any of the options 1 or 2 that we have chosen do not forget to close and re open Internet Explorer indicating on the bar of directions the new IP address of the already configure
3. Analog Inputs pots and a board of this type can be connected up to the Mother Board The Mother Board can manage 16 Analog Inputs pots with a connected board 3 6 1 Supported Components This board supports any type of pots Pots 3 7 FAST INTERFACE AND INTERCONNECTION CARD GIC V3 5 The GIC V3 5 Boards General Interface Card facilitate the connections with the different components because they allow to connect backpanels with IDC connectors of less than 40 pins or allow to connect components by means of free wiring to threaded terminals so it will not be necessary welds Of this form the connections are easy to make are clean and allow a better maintenance beside giving a bigger reliability to any solution For it a GIC V3 5 can be connected to the IDC connectors of 40 pins of any of the SimCards and in this way already it is possible to access to the different pins both by flat cables and by free wiring 04 USER MANUAL da SIMCARD SC MB ETHERNET MAN US E RR 10 007 21 User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators G www sismo soluciones com Sano SOLUCIONES Plug amp Fly INS LATION AND CONFIGURATION 4 1 PREVIOUS REQUIREMENTS They are compatible with any operating system it only is necessary to have a computer with an ETHERNET free port It is also possible to use a HUB or SWITCH that allows to centralize the wired up of a network and to be
4. Input 32 VCC 5V 04 USER MANUAL da SIMCARD SC MB ETHERNET MAN US E RR 10 007 14 User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators G www sismo soluciones com asmo SOLUCIONES Plug amp Fly 3 2 2 2 Inputs DI2 Connector In this IDC connector of 40 pines are available the discreet inputs from 33 to 64 All the grounds GND are common Input 33 Input 35 Input 37 Input 38 Input 39 Input 40 VCC 5V Input 41 Input 42 Input 43 Input 44 Input 45 Input 46 Input 47 Input 48 VCC 5V Input 49 Input 50 Input 51 Input 52 Input 53 Input 54 Input 55 input 56 vec 5V E GND Input 57 input 58 Input 59 Input 60 Input 61 input 62 Input 63 Input 64 VCC 5V 3 0 GND 04 USER MANUAL da SIMCARD SC MB ETHERNET MAN US E RR 10 007 15 User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators G SISMO SOLUCIONES Plug amp Fly www sismo soluciones com 3 3 SIMCARD 64 DIGITAL OUTPUTS DAUGHTER BOARD SC 64DO DB This board is connected by means of a flat cable of 10 wires to the Mother Board Each board has 64 digital outputs and 2 boards of this type can be connected up to the Mother Board The Mother Board can manage 192 digital outputs with two connected boards 3 3 1 Supported Components The components that can be connected up to this board are all leds reles etc The mos
5. able to extend it There are two ways of connecting the Mother Board to the control computer 1 By direct way with only a cable it is necessary a crossed cable type that connects the Mother Board with the computer 2 By means of a Switch or Hub it can be used indistinctly a crossed cable or a normal cable The normal situation is that the Board is connected to the computer where Microsoft Flight Simulator is installed because it must accede to its functions through the IOCP or of FSUIPC communication protocol which is going to be used Nevertheless in network configuration the Board can be connected to other computers but for that purpose the network must be configured adequately and this is not inside the area of this manual Anyway this manual will be useful for orientating to the user how he must do it 4 2 HARDWARE CONFIGURATION OF THE BOARD m To configure the Board and once the connection to the control computer is made directly or by means of a Switch or Hub proceed to supply externally the Ethernet SC MMB Mother Board Optional Note It is recommended to have the rest of hardware and computers disconnected from the network for configuring the Board It is indispensable that the voltage of supply that is received in the terminals of the Board is 5V DC A lower voltage is not enough for a well functioning of the Board and a higher voltage can damage the connected servos The scheme on the right shows the corre
6. de dea exte predsteminade que neme la comunicaci n erre redes conectadas entre s validar configuraci n salir Usar la siguiente drecc n 1P Drecain 192 168 1 101 Puerta de enlace predetermnede Cee 6 Finally the windows will be closed when Ok Aceptar has been pressed From this moment the change has been saved User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators G www sismo soluciones com SISMO SOLUCIONES Plug amp Fly 7 Once the process has finished both the IP address of the Board and the IP of the control computer will have the same range in this case range 1 Now to accede to the configuration page of the Board will be possible Note 1 This is only an example for Windows 7 in an orientated way The way of changing the IP for other operating systems can be found into multiple tutorials or Internet Nota 2 Find also video tutorials at the section of Technical Videos in the main SISMO SOLUCIONES web page and learn better how to configure the Mother Board change the IP Resouces Address etc Sismo in YouTube o Technical SER As we will see along the manual this provisional change in the IP address does not suppose a problem for the configuration of the rest of equipments that the user had previously because once we accede to the configuration page of the SC MB Boards it will be possible to restore the previous IP addresses as wel
7. each segment to check the displays We can mark the orange segments AA of the displays to verify that they nidos e work adequately as well as to ARA change the intensity brightness or activate deactivate a concrete display doing click on the corresponding number of each display 69102920 70150 30 310 10916020320 Brightness SEND TEST ALL Screen 4 Daughters Boards With double click on the Daughters Boards the user will be able to observe 19010107930 1000900050009 HO 00 The INPUTS state ON green gt sonononovososono OFF grey for the Input Daughters a EE dS bi Ai Boards 1010101000 00000 Activate or deactivate OUTPUTS in owe Ser aro TEST AL the Output Daughters Boards Do the test of the displays in the Displays Daughters Boards Check the analogical inputs or pots in the ADC Daughters Boards And verify the servos in the Servos Daughters Boards marking before the icon ACTIVATE Servo n n servo to activating deactivate Another icon called ACTIVATE AE y YOUR ALL SERV is used to activate eam the 16 servos of the Board re 1909 00 4000 000090 30n noso noso so 40 20 mo m9 0 4952000 sa no nomo moua uono 04 USER MANUAL Ja SIMCARD SC MB ETHERNET MAN US E RR 10 007 36 User Manual SimCard SC MB Ethernet Ed4 docx Fli
8. 00 to Display 15 All the grounds GND are common DY1 CONNECTOR IDC40 Seg_DP 1 GND Display 00 Dig_11 Display 01 Display 02 Dig_31 Display 03 Display 04 Display 05 Display 06 Display 07 04 USER MANUAL a oe SIMCARD SC MB ETHERNET MAN US E RR 10 007 19 User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators G www sismo soluciones com SISMO SOLUCIONES Plug amp Fly Display 08 E Display 09 Display 10 Display 11 Display 12 7 Display 13 Display 14 3 5 2 2 Displays DY2 Connector In this IDC connector of 40 pines are available 16 displays of 7 segments from Display 16 to Display 31 All the grounds GND are common DY2 CONNECTOI Display 16 i Display 17 Display 18 7 Display 19 Display 20 i Display 21 Display 22 j j Display 23 isplay 24 7 A Display 25 Display 26 7 Display 27 Display 28 ig 5 4 Display 29 Display 30 ig a i Display 31 04 USER MANUAL Aa SIMCARD SC MB ETHERNET MAN US E RR 10 007 20 User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators www sismo soluciones com Y SISMO SOLUCIONES Plug amp Fly 3 6 SIMCARD 11 ANALOG INPUT DAUGHTER BOARD SC 11AI DB lt FOTO gt This board is connected by means of a flat cable of 10 wires to the Mother Board Each board can control 11
9. 08 VCC 5V 9 0 GND Output 09 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 VCC 5V 2 GND Output 17 Output 18 Output 19 Output 20 Output 21 Output 22 Output 23 Output 24 vec 5V 2 30 GND Output 25 Output 26 Output 27 Output 28 Output 29 Output 30 Output 31 Output 32 VCC 5V c GND 04 USER MANUAL AS SIMCARD SC MB ETHERNET MAN US E RR 10 007 9 User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators GO www sismo soluciones com SISMO SOLUCIONES Plug amp Fly 3 1 3 2 DO2 Connector In this IDC connector of 40 pines are available the discreet outputs from 33 to 64 All the grounds GND are common DO2 CONNECTO Output 33 Output 34 Output 35 Output 36 Output 37 Output 38 Output 39 Output 40 VCC 5V 9 0 GND Output 41 Output 42 Output 43 Output 44 Output 45 Output 46 Output 47 Output 48 vec 5V 9 GND Output 49 Output 50 Output 51 Output 52 Output 53 Output 54 Output 55 Output 56 vec 5V 29 30 GND Output 57 Output 58 Output 59 Output 60 Output 61 Output 62 Output 63 Output 64 vec 5V 3 0 GND 3 1 4 Displays The Mother Board has a total of 32 displays of 7 segments of common cathode which are distributed in two connectors IDC of 40 pines each one 04 USER MANUAL AS SIMCARD SC MB
10. 6 Output 47 Output 48 vec 5V 9 2 GND Output 49 Output 50 Output 51 Output 52 Output 53 Output 54 Output 55 Output 56 VCC 5V 9 30 GND Output 57 Output 58 Output 59 Output 60 Output 61 Output 62 Output 63 Output 64 VCC 5V 9 4 GND This board is connected by means of a flat cable of 10 wires to the Mother Board Each board can control 14 servos and a board of this type can be connected up to the Mother Board The Mother Board can manage 14 servos with a connected board 3 4 1 Supported Components This board supports any type of servo in their different formats Servos User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators G www sismo soluciones com SISMO SOLUCIONES Plug amp Fly 3 5 SIMCARD 32 DISPLAYS DAUGHTER BOARD SC 32DISP DB This board is connected by means of a flat cable of 10 wires to the Mother Board Each board can control 32 displays of 7 segments in common cathodes and a board of this type can be connected up to the Mother Board The Mother Board can manage 64 displays with a connected board 3 5 1 Supported Components This board supports any type of display of 7 segments in common cathode Displays 7 Segments 3 5 2 Outputs Map 3 5 2 1 Displays DY1 Connector In this IDC connector of 40 pines are available 16 displays of 7 segments from Display
11. ETHERNET MAN US E RR 10 007 10 User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators CO www sismo soluciones com Sano SOLUCIONES Plug amp Fly 3 1 4 1 DY1 Connector In this IDC connector of 40 pines are available 16 displays of 7 segments from Display 00 to Display 15 All the grounds GND are common DY1 CONNECTO Display 00 Display 01 Display 02 E Display 03 Display 04 Display 05 Display 06 Display 07 Display 08 Display 09 Display 10 j Display 11 Display 12 Display 13 Display 14 7 Display 15 04 USER MANUAL Aa SIMCARD SC MB ETHERNET MAN US E RR 10 007 1 User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators G www sismo soluciones com Sano SOLUCIONES Plug amp Fly 3 1 4 2 DY2 Connector In this IDC connector of 40 pines are available 16 displays of 7 segments from Display 16 to Display 31 All the grounds GND are common DY2 CONNECTO Display 16 Display 17 Display 18 T Display 19 Display 20 Display 21 Display 22 Display 23 Display 24 Display 25 Display 26 Display 27 Display 28 g Display 29 Display 30 Display 31 04 USER MANUAL Aa SIMCARD SC MB ETHERNET MAN US E RR 10 007 12 User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators CO www sismo soluciones com SISMO SOLUCIO
12. Inputs IDC40 e 64 Digital TTL Outputs IDC40 e 32 Displays of 7 segments common cathode IDC40 e 5 Analog Inputs 3 1 1 Supported Components The components that can be connected to this board are all kinds of switches push buttons rotarys encoder leds displays reles etc The most habitual components are Rotary Encoders Switch Buttons 3 8 Push Bottons Rotary Switch 04 USER MANUAL A pa l SIMCARD SC MB ETHERNET MAN US E RR 10 007 6 User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators G www sismo soluciones com Po SOLUCIONES Plug amp Fly Displays 7 Segments Leds Analog Inputs 3 1 2 Inputs Map 3 1 2 1 DI1 Connector In this IDC connector of 40 pines are available the discreet inputs from 01 to 32 All the grounds GND are common Input 01 Input 02 Input 03 Input 04 Input 05 Input 06 Input 07 Input 08 vec 5V 9 0 GND Input 09 Input 10 Input 11 Input 12 Input 13 Input 14 Input 15 Input 16 VCC 5V N Input 17 Input 18 Input 19 Input 20 Input 21 Input 22 Input 23 Input 24 VCC 5V Input 25 Input 26 Input 27 Input 28 04 USER MANUAL SIMCARD SC MB ETHERNET MAN US E RR 10 007 Fi User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators CO www sismo soluciones com asmo SOLUCIONES Plug amp Fly I
13. N OFF SC MDDB DISPLAYS ON OFF SC MAIDB ADCS CON OFF COE L C Sismo Soluciones SL amp ABORCS amp MATOCOMASI 2010 www 737agsim com Three configuration fields appear NETWORK CONFIG UDP CONFIG and DAUGHTER BOARDS CONFIG All these fields have the values by default For its correct configuration there is detailed the meaning content and way to proceed in each item 4 2 1 2 Network Config MAC ADDRESS it is the hardware address of the Mother Board and therefore it is unique and cannot be modified The last four digits are in hexadecimal and give name to the variable part of the serial number of the Board The invariable part is fixed as SC MB SC MMBnnnn Please don t forget this number Probably you will need in several applications The serial number of the Board will be also used to accede to its functionalities when someone is going to program in SC Pascal IP ADDRESS this section is used to modify the IP address of the Mother Board which has by default 198 168 1 150 In case of being modified do not forget that it must have the same IP range that the IP address of the control computer It is the moment to proceed to restore the IP address which the user had configured its equipment 04 USER MANUAL aS SIMCARD SC MB ETHERNET MAN US E RR 10 007 28 User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators G www sismo soluciones com Gamo SOLUCIONES Plug amp Fly 4 2 1 3 Note
14. NES Plug amp Fly 3 2 SIMCARD 64 DIGITAL INPUTS DAUGHTER BOARD SC 64DI DB This board is connected by means of a flat cable of 10 wires to the Mother Board Each board has 64 digital inputs and 2 boards of this type can be connected up to the Mother Board The Mother Board can manage 192 digital inputs with two connected boards 3 2 1 Supported Components The components that can be connected up to this board are all kinds of switches push buttons rotarys encoder etc The most habitual components are a Rotary Encoders Switch Buttons si Push Bottons Rotary Switch User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators G www sismo soluciones com Gamo SOLUCIONES Plug amp Fly 3 2 2 Inputs Map The map of connections of this board is distributed in 2 available connectors as is described next 3 2 2 1 Inputs DI1 Connector In this IDC connector of 40 pines are available the discreet inputs from 01 to 32 All the grounds GND are common Input 01 Input 02 Input 03 Input 04 Input 05 Input 06 Input 07 Input 08 vec 5V Input 09 Input 10 Input 11 Input 12 Input 13 Input 14 Input 15 Input 16 VCC 5V Input 17 Input 18 Input 19 Input 20 Input 21 Input 22 Input 23 Input 24 VCC 5V Input 25 Input 26 Input 27 Input 28 Input 29 Input 30 Input 31
15. NUAL SIMCARD SC MB ETHERNET MAN US E RR 10 007 3 User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators GO www sismo soluciones com Sano SOLUCIONES Plug amp Fly 1 INTRODUCTION 1 11 PURPOSE The intention of this document is to describe a global overview of the new SimCard SC MB Mother Board Ethernet 2 OVERVIEW Welcome to one of the boards of the Simcards family named SC MB specially designed for the control and management of inputs and outputs of equipments and modules of simulators made or not by Sismo as well as also of any other equipment or system that it needs of its service This new generation of electronic board has supposed a new challenge for Sismo Soluciones reaching in this aspect equivalent levels of technology functionality and benefits as those of the current professional industry The main characteristic of the board is so striking as that its connection is made by means of an Ethernet bus which is a standard of networks of computers of local area In this way it will be possible to do direct connection to the equipment or computer of control as with a bus USB 2 0 but with the advantage of that the communications and transfer of data will be much more effective and rapid These properties are important for systems of real time as the simulators The Ethernet bus awards the possibility of allowing to centralize the wires of a network or to be able to extend it connecting the bo
16. SIMCARD SC MB ETHERNET 2005 2013 Sismo Soluciones All Right Reserved Flight Simulators G SISMO SOLUCIONES Plug amp Fly www sismo soluciones com INDEX 1 Introduction 11 Purpose 2 Overview 3 Basic Instructions 5 3 1 SimCard Mother Board SC MB 3 1 1 Supported Components 3 1 2 Inputs Map 3 1 3 Outputs Map 3 14 Displays 3 2 SimCard 64 Digital Inputs Daughter Board SC 64DI DB 3 2 1 Supported Components 3 2 2 Inputs Map 3 3 SimCard 64 Digital Outputs Daughter Board SC 64DO DB 3 3 1 Supported Components 3 3 2 Outputs Map 3 4 SimCard 14 Servos Daughter Board SC 14SERV DB 3 4 1 Supported Components 3 5 SimCard 32 Displays Daughter Board SC 32DISP DB 3 5 1 Supported Components 3 5 2 Outputs Map 3 6 SimCard 11 Analog Input Daughter Board SC 11AI DB 3 6 1 Supported Components 37 Fast Interface and Interconnection Card GIC V3 5 4 Installation and Configuration 4 1 Previous requirements 4 2 Hardware Configuration of the Board 4 2 1 Configuration Page and IP Address of the SC MB Ethernet 4 3 Example of Connection Scheme Type 5 Hardware Test 6 Flight Simulator Use 7 Others Applications suena User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators GO www sismo soluciones com SISMO SOLUCIONES Plug amp Fly 8 FAQs 04 USER MA
17. an one equipment connected to the network and improve the communications END OF DOCUMENT 04 USER MANUAL A a SIMCARD SC MB ETHERNET MAN US E RR 10 007 39 User Manual SimCard SC MB Ethernet Ed4 docx
18. ard through Switch or Hub devices According to this it also is possible to control the board to long distance through Internet to do checkups of the hardware etc as well as connection through WIFI Wireless by means of a computer connected to the local network in which the board is connected that means a real revolution for the flight simulators Other one of the new characteristics and not less important is that this board works as mother card being only necessary a SimCard SC MB Ethernet to manage and control everything but logically with a limit of inputs and outputs 04 USER MANUAL Aa SIMCARD SC MB ETHERNET MAN US E RR 10 007 4 User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators G www sismo soluciones com Sano SOLUCIONES Plug amp Fly This is not a limitation problem quite the opposite because the board also has enabled connectors for the connection of expanding or daughters boards according to the needs of a major number of inputs outputs etc It can be connected so many Daughters Boards like is needed The type of connection is by means of a simple flat cable which will join in a direct manner the Mother board with all the Daughter Boards respectively These connectors are a standard of connection and therefore they are also compatible with other boards or components We name family of Simcards SC MB boards to the group formed by the Mother Board and each of the types of the Daughters Boards wh
19. be networked is that the 4 elements must have the same IP range For example 192 168 1 150 Mother Board 1 192 168 1 151 Mother Board 2 192 168 1 152 computer 1 192 168 1 153 computer 2 SWITCH Autosense In the same used SWITCH the Ethernet cable to provide connection for internet can also be plugged 04 USER MANUAL User Manual SimCard SC MB Ethernet Ed4 docx SIMCARD SC MB ETHERNET MAN US E RR 10 007 33 Flight Simulators GO www sismo soluciones com Sano SOLUCIONES Plug amp Fly HARDWARE TEST The language of programming that specifically has developed Sismo Soluciones is SC Pascal and in spite of the fact that the Board can be controlled for any another language previous its appropriate configuration in this manual only and exclusively is indicated the necessary requirements to control the Board with the SC Pascal editor compiler being enough for every user who want to interact with the simulator SC Pascal has a section for the checking of the Hardware Inputs and Outputs Displays Servos and Adc s for both the Mother and Daughters Boards In this way the user can verify the hardware represent the active inputs activate or deactivate the outputs check the displays and verify the servos and adc s For being able to do these checks download the last version of SC Pascal V5 for SC MB Simcards s family which is available in the download zone of the web www 737ngsim com For more informati
20. ct manner to supply the Board 04 USER MANUAL da SIMCARD SC MB ETHERNET MAN US E RR 10 007 22 User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators CO www sismo soluciones com Gamo SOLUCIONES Plug amp Fly IMPORTANT the Board might be affected if the positive and negative terminals are not the shown ones in the scheme For those users who do not want to use the green threaded terminals it is possible to supply the Board through a connector qualified to do it DC_CON For safety also check with a multimeter that the voltaje in the terminals of the scheme is 5V DC From this moment the Board must be perfectly connected through Ethernet bus to the control computer or the network In the SC MB SimCards family are 4 types of JUMPERS Each one has a specific function When purchasing the Board the user will find the jumpers properly located in their places by default The advice is not to change the place of the jumpers and do not remove it unless the user has a particular interest to For those ones who are interested the table below shows the function of the each jumper The jumpers JP_PGC and JP_PGD must be always placed because they are the managers of the Jumpers programming of the chip of the Mother Board JP_PGC y JP_PGD and in case to be removed the Board will stop working 04 USER MANUAL SIMCARD SC MB ETHERNET MAN US E RR 10 007 23 User Manual SimCard SC MB Ether
21. d Log 9 a Listen UDP PORT Z View Compiler Debug 3 Refresh Command Help About Y View Boards Boards Line Save view Hardware Help About Ethernet Cards Hardware EE UlocpPNP gt The normal situation is that the port is enabled opened but it is possible that the control computer has this port closed In order to assure it works it must be enabled see chapter 8 FAQ and know how to open ports in computers Once all the sections are correctly filled out as in this manual has been described proceed to press on SAVE BOARD CONFIG to save the new configuration of the Mother Board Note Wait at least 5 seconds while the data are saved SC MMB0000 CONFIG PAGE N MAC ADDRESS 00 04 A3 00 00 00 a her IP ADDRESS 192 168 1 150 1024 MASK 255 255 255 0 AARDE 3 1026 DEFAULT GATEWAY 192 168 1 1 si SAVE BOARD CONFIG RESTORE DEFAULT VALUES In order that it makes effect and once saved it is indispensable to close Internet Explorer and to return to opening After that the new IP address of the Mother Board must be indicated on the bar of directions This step must be done necessarily due to the exigency of the Internet protocol Explorer ole pt Close and return to opening KS Internet Explorer Once the page has been correctly loaded with the new IP address the information of configuration will be visualized At this moment you can choose 3 options
22. d Mother Board 04 USERMANUAL Aa SIMCARD SC MB ETHERNET MAN US E RR 10 007 31 User Manual SimCard SC MB Ethernet Ed4 docx Y Flight Simulators www sismo soluciones com Pane SOLUCIONES Plug amp Fly 4 2 1 4 Daughter Boards Config In this field we must indicate the Daughters Bards which are going to be connected to the Mother Board We can mark all those that we wish though they are not connected but this only will do to slow down the time of data processing We advice to mark only the Daughters Boards connected to the Mother Board DAUGTHER BOARDS CONFIG The configuration page allows activating a total of 2 SC MDODB OUTPUTS Inputs Daughters Boards 2 of Outputs 1 of GC MODE OUIFUTS Displays 1 of Servos and 1 ADC pots All these are SC MDIDB INPUTS1 k considered enough to manage any system or SC MDIDB INPUTS 2 x ith ber of inputs output SC MEDE EERYOE equipment with a great number of inputs outputs SC MDDB DISPLAYS ON OFF SC MAIDB ADCS ON OFF SAVE DAUGTHER CONFIG Pressing with the mouse on SAVE DAUGHTER is enough for finishing the configuration and activation of the Daughters Boards It will be saved automatically not being this time necessarily to restart Internet Explorer Once made and saved the configuration of the Mother Board and the Daughters Boards you will not have to return to configure anymore unless the user wants to do a specific change in the configuration of the Boards Note i
23. dress 192 168 1 100 Mask Subnet 255 255 255 0 Server Control Computer IP Address 192 168 1 150 Mask Subnet 255 255 255 0 04 USER MANUAL da SIMCARD SC MB ETHERNET User Manual SimCard SC MB Ethernet Ed4 docx MAN US E RR 10 007 24 Flight Simulators G www sismo soluciones com SISMO SOLUCIONES Plug amp Fiy See in the above example that the IP address range of the control computer which is marked in red range 1 is the same that in the Mother Board This specification is a condition necessary to enable that the network communication occurs between the Mother Board and other equipments Like the Mother Board has by default an IP address of range 1 the first thing that the user must do is to check if the IP address of the control computer has also range 1 Here s one way to know the personal IP address of your computer 1 Go to Start gt Run An input box will appear with a flashing cursor 2 Type cmd Click on OK or press the Enter key on your keyboard Ejecutar e Internet L Mis documentos y Correo electr nico ie cdo min vasca Famire E Mis sitios de red erasoan Escriba el nombre del programa carpeta documento o recurso de Internet que desea que Windows abra 2 Documentos recientes gt bom Abrir 2 Ey Mis im genes Aceptar Cancelar Examinar Adobe Reader 9 oft Office Word 2007 E secre ras arca E 3 A new black colo
24. dules of a 737NG Simulator FWD Overhead 1 SimCard Mother SC MMB Board 3 SimCards Daughter Boards Notes e For facilitating the hook up of a big and completely connected module as this case is GIC V2 cards are used blue cards e Ifthe Overhead takes operative gauges for servos it is necessary to add a new Daughter Board e The Overhead has only an Ethernet port for the whole set and does not need any type of HUB as in case of USB e It has a power connector of 5V e If this module had the wireless kit it only would be necessary to connect supply Complete MIP 1 SimCard Mother SC MMB Board MCP and EFIS 1 SimCard Mother SC MMB Board 04 USER MANUAL da SIMCARD SC MB ETHERNET MAN US E RR 10 007 37 User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators CO www sismo soluciones com SISMO SOLUCIONES Plug amp Fly OTHERS APPLICATIONS The cards of the SimCards family named SC MB are specially designed for the control and management of inputs and outputs of equipments and modules of simulators made or not by Sismo as well as any other equipment or system of real time which need control of elements being some examples of application Flight simulators cars trains etc Systems of centralized control CTC type Sending of data by remote Control of elements Systems of roads Etc 04 USER MANUAL Aa SIMCARD SC MB ETHERNET MAN US E RR 10 007 38 User Manual SimCard SC MB Ethe
25. f in some of the necessary steps to configure the Board appears signs of difficulty of load in the configuration page do not worry it is normal and is due to the Internet Protocol Explorer For solving this problem Internet Explore must be closed and restart it indicating on the bar of directions the IP address of the Board If this method does not work proceed to remove the power supply and restart to connect everything again 04 USERMANUAL Aa SIMCARD SC MB ETHERNET MAN US E RR 10 007 32 User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators www sismo soluciones com Y rA SISMO SOLUCIONES Plug amp Fly 4 3 EXAMPLE OF CONNECTION SCHEME TYPE 4 im 1 Bus de conexi n Mother Daughters cable plano 10 hilos Each computer and each Board must have an Ethernet port normally used for connecting to the internet network 4 Ethernet cables will plugged each of these 4 equipments to a device SWITCH HUB or ROUTER with Autosense in order a communication between them occurs ha This is an example of network configuration composed by 2 computers which control and manage 2 Mother Boards At the same time components complete flight simulator modules SISMO PRMs etc are connected to the Mother Board For this specific issue 2 types of configuration can be done a 1 computer which controls both Mother Boards b Each computer controls only one Mother Board The unique requirement to
26. ght Simulators CO www sismo soluciones com Sano SOLUCIONES Plug amp Fly 6 FLIGHT SIMULATOR U With the new SC MB SimCards you can control all the elements and components of any flight simulator Obviously Sismo uses these Boards for the modules of the TERAS 737NG simulator which develops and commercializes in this manner the solution offered by Sismo is very complete because not only the user can have panels and hardware of great quality TERAS family in addition it has the electronics of control needed and certainly the software to interact with the different simulators of the market These Boards can be used not only by the modules of Sismo much more with any other type of modules or for those who want to build their own simulators the Boards are ideal together with the GIC cards and with this solution forget to have problems with the connections No other card of the market offers so much power and so many benefits besides all the advantages described in this manual Could you imagine having a simulator controlled by wireless With this technology already it is possible now we can forget the problems of the quantity of USB ports the distances etc Calculate the cards that you need to equalize to an alone SC MMB in some cases it is needed until 5 different cards with an obsolete technology In this case the final price of these solutions are practically the same than the solution with an alone SimCard Some examples for mo
27. ich can be connected Its control can be made by means of programming in SC Pascal language which specifically has been developed by Sismo Soluciones and which can be downloaded for free Nevertheless they are prepared to accede by any other type of language with a previous programming configuration of the board For those users who do not have many computing knowledge but have the illusion to build a flight simulator in Sismo web and different forums they will find examples of how programming easily the board as well as scripts for diverse simulators BASIC R IONS In the following picture appears the whole range of boards developed by Sismo Soluciones SC MB SimCard Mother Board SC 64DI DB SimCard 64 Digital Inputs Daugther Board SC 64DO DB SimCard 64 Digital Outputs Daugther Board SC 14SERV DB SimCard 14 Servos Daugther Board SC 32DISP DB SimCard 32 Displays Daugther Board SC 11AI DB SimCard 11 Analog Inputs Daugther Board 04 USER MANUAL Ja SIMCARD SC MB ETHERNET MAN US E RR 10 007 5 User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators CO www sismo soluciones com Yima SOLUCIONES Plug amp Fly 3 1 SIMCARD MOTHER BOARD SC MB The Mother Board is connected to the network by means of an Ethernet port and can expand its functionalities by means of Daughter Boards The board has connection for 5V DC The inputs outputs that it has are the following e 64 Digital
28. l as give a new IP address to the Mother Board with the IP range that the user wants to use in the set of his equipments Now for being able to accede to the configuration of the Board is necessary to open Internet Explorer Write inside of the address bar in Internet Explorer the IP of the Mother Board http 192 168 1 150 QO le monss The configuration page is loaded and as headline appears the serial number of the Mother Board in red colour in addiction of the CONFIG PAGE words which indicate that effectively the configuration page of the Board has been charged USER MANUAL User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators G www sismo soluciones com asmo SOLUCIONES Plug amp Fly SCMNIECODO Config Page Sismo Soluciones SL Windowsinieine Bplorer QO Ereman Jae x 2 ss P Gp Favoritos qi 8 Sitios sugeridos fp M s complementos 5C MMB0000 Config Page Sismo Soluciones S L tr Eh y P gina Seguridad y Heramienas e SC MMB0000 CONFIG PAGE NETWORK CONFIG N MAC ADDRESS 00 04 A3 00 00 00 o NI IP ADDRESS 162 168 1150 E LOCAL PORT 1024 MASK 255 255 255 0 aa z 1025 DEFAULT GATEWAY 182 168 1 7 ias SAVEBOARD CONFIG RESTORE DEFAULT VALUES DAUGTHER BOARDS CONFIG SC MDODB OUTPUTSI ON OFF SC MDODB OUTPUTS ON OFF SC MDIDB INPUTS DON OFF SC MDIDB INPUTS2 ON OFF SC MSDB SERVOS CO
29. net Ed4 docx Flight Simulators www sismo soluciones com Y SISMO SOLUCIONES Plug amp Fly Jumper JP2 Jumper JP4 In the same way if the JP1 jumper is removed the inputs of the Board will be disabled The JP1 jumper provides the possibility of selecting the wished logic for the Inputs that is to say if we change the cover of the jumper from the 1 2 pins to the 2 3 pins the logic will be reversed in a sense or other one as is convenient for the user This type of jumpers can be located in the Mother Board and in the Inputs Daughter Board The JP2 jumper which only is localizable in the Mother Board It will always have to be placed between the central pin and 5V The advice now is to check visually that the jumpers are located in their correct place to ensure the optimum performance of the Board 4 2 1 Configuration Page and IP Address of the SC MB Ethernet 4 2 1 1 IP Address by Default The default IP address of the Mother Board is 192 168 1 150 This data is important in order that the first time the Board is read In this case the computer or the network in which we connect the Board must have the same range of IP address that is to say range 1 As an example the diagram below shows the items required to configure a basic network or local network 1 computer only Later another diagram will illustrate a more complex network multiple computers Basic Interface IP Ad
30. nput 29 Input 30 Input 31 Input 32 VCC 5V 39 0 GND 3 1 2 2 DI2 Connector In this IDC connector of 40 pines are available the discreet inputs from 33 to 64 All the grounds GND are common Input 33 Input 34 Input 35 input 36 Input 37 Input 38 Input 39 Input 40 VCC 5V Input 41 Input 42 Input 43 Input 44 Input 45 Input 46 Input 47 Input 48 VCC 5V Input 49 Input 50 Input 51 Input 52 Input 53 Input 54 Input 55 Input 56 VCC 5V Input 57 Input 58 Input 59 Input 60 Input 61 Input 62 Input 63 Input 64 VCC 5V 04 USER MANUAL Ja SIMCARD SC MB ETHERNET MAN US E RR 10 007 8 User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators G www sismo soluciones com SISMO SOLUCIONES Plug amp Fly 3 1 3 Outputs Map The Mother Board has a total of 64 outputs in common cathode configuration which are distributed in two connectors of 40 pines each one this means that the common part of all the outputs is the negative cathode The scheme of connection in common cathode format for the connection of leds is shown in this image 3 1 3 1 DO1 Connector In this IDC connector of 40 pines are available the discreet outputs from 01 to 32 All the grounds GND are common DO1 CONNECTOR IDC40 Digital Outputs Output 01 Output 02 Output 03 Output 04 Output 05 Output 06 Output 07 Output
31. ol v4 TCP IPv4 4 Again a new window is opened Mark the option Use the following IP Address in order that the zone where it will be possible to write the new IP address of the control computer is enabled Ej IP address 192 168 1 101 5 As subnet mask to write for example 255 255 255 0 and in the third field 192 168 1 1 P gt Panetdeconta Rede elntemet Conssonee dered 49 Buscar Conesiones ce red Organizar Deshabilitar este d Y Propiedades de Conexi n de res local ST Covai n de 3catoca tonces dered cere Red no identificada S NIC de Fast Ethernet Restt Conectar usando Puede hacer que la configuraci n IP se esgre sutom tcomente slo red es compatible con esta funcionalded De lo contara deber consular con el edrinistredar de red cu l esla configuraci n IP epropiede EE scenes recci n aiondtcanente WC Foe Erenet Reatek RTLOIIIC Esta conan us los sguientes dementos OF Ciente pare redes Mons El Frogramader de paquetes CoS E comparti impresoras y archivos pare redes P M scora de subred 255 255 255 0 e Protocole de Intemet versi n 6 TCF IPVE A i Protocole de Intemet versi n 4 TCF IPva A Controlador de E S del asignador de delos T sa arcs AAG Obtener la direcci n de servidor DNS autom ticamente 6 Usar las squentes drescones de servidor DNS Desoipci n Servidor DNS alternativo Protocelo TCP IP E pratoclo de red
32. on read the manuals and tutorials of SC Pascal Screen 1 SC Pascal ore SE PASCALI SEM SOLUCIONES tocon ox D A A MD o pe Launch SC Pascal V5 pressing on SC Pascal Logo and this screen will appear a A 04 USER MANUAL A a SIMCARD SC MB ETHERNET MAN US E RR 10 007 34 User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators Y www sismo soluciones com Pos SOLUCIONES i oy In the left part can be observed the serial number of the Mother Board Home Options accompanied of all the Daughters Q a ih l Boards which are connected in Ext Open Open New N SCPASCAL Project File Project F these moment to the computer and san ae have been correctly configured E Hardware x f Ethernet MB 2 This is only an example for that it SC HMBO000 OUTI will never have these serial ea SC MMBO0000 SERVO numbers SC MMB0000 DISPLAY SC MMBODOO ADC SC MMBODOO IN1 Serial Number A ofthe Mother Board this is an example For launching the application Hardware test do click with the mouse on the serial number of the Mother Board or on any of the Daughters Boards which were connected and configured Color Code ON gt green OFF gt grey Last active Input gt red Olea Exit Open SCPASCAL Project Hardware x Ethernet MB E sc mmBoo00 SC MMB0000 OUT1 SC MMB0000 0UT2 SC MMB0000 SERVO SC MMB0000 DISPLAY
33. r window is opened SB WINRAR E Impresoras y faxes Here type ipconfig NCE microsoft Office Excel 2007 0 Ayuda y soporte t cnico 4 Press the Enter key on your keyboard pes and IP Address will be shown Inicio nd Settings raci n IP de Windows i n espec fica DNS and Setti 04 USER MANUAL Te SIMCARD SC MB ETHERNET MAN US E RR 10 007 25 User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators G www sismo soluciones com SISMO SOLUCIONES Plug amp Fly The user does not have to change the IP address of the control computer if it turns out to be range 1 That is to say that the equipment is already configured with a right IP address If the control computer does not have range 1 as in the previous example which the IP address is range 2 see green box and inside yellow box the user must temporarily change the IP address of his control computer to range 1 in order that the card can be read by the computer the first time because as it was noted above the Mother Board comes with a default IP address of range 1 Follow the next steps to change the IP address of the control computer E g for Windows 7 1 Goto Start gt Control panel gt Network and Sharing Center gt Configuraci n del adaptador 2 Press with the right button of the mouse on the icon of Local Area Connection and later press on General Properties 3 After a window is opened Make double click on Internet protoc
34. rnet Ed4 docx Flight Simulators G www sismo soluciones com SISMO SOLUCIONES Plug amp Fly FAQS How can the user enable open any port in the computer As example the necessary steps to open manually ports in Windows XP will be explained For others operating systems it can be done after to look for easily how to do it through any internet browser 1 2 EN Click Start and then click My Network Places Under Network Tasks click View Network Connections Or right click My Network Places on the desktop and then click Properties Right click the connection that you use for the Internet and then click Properties Click the Advanced tab and then click Settings Note If the Settings button is unavailable ICF is not enabled on this connection and you do not have to open any ports because they are all already open Click Add to open a new port In the Description box type a friendly name For example type File Sharing Port 445 In the Name or IP address of the computer hosting this service on your network box type 127 0 0 1 Note You can specify the IP address of an internal computer But you typically will use 127 0 0 1 In the External port and Internal port boxes type the port number Generally this number is the same Click UDP and then click OK 10 Repeat steps 1 through 9 for each port that you want to open Advice disable completely the Firewall Windows in case to have more th
35. t habitual components are Reles Leds User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators CO www sismo soluciones com SISMO SOLUCIONES Plug amp Fly 3 3 2 Outputs Map 3 3 2 1 Outputs DO1 Connector In this IDC connector of 40 pines are available the discreet outputs from 01 to 32 All the grounds GND are common DO1 CONNECTO Digital Outputs Output 01 Output 02 Output 03 Output 04 Output 05 Output 06 Output 07 Output 08 Vcc 5V 9 c GND Output 09 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 vec 5V 0 GND Output 17 Output 18 Output 19 Output 20 Output 21 Output 22 Output 23 Output 24 VCC 5V E GND Output 25 Output 26 Output 27 Output 28 Output 29 Output 30 Output 31 Output 32 vec 5V 39 0 GND 3 3 2 2 Outputs DO2 Connector In this IDC connector of 40 pines are available the discreet outputs from 33 to 64 All the grounds GND are common DO2 CONNECTOR IDC40 Digital Outputs Output 33 Output 34 Output 35 Output 36 Output 37 Output 38 Output 39 Output 40 VCC 5V 9 GND Output 41 Output 42 Output 43 Output 44 04 USER MANUAL n SIMCARD SC MB ETHERNET MAN US E RR 10 007 17 User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators G www sismo soluciones com asmo SOLUCIONES Plug amp Fly Output 45 Output 4
36. ter must have the same range that the IP address of the Mother Board named in the section IP ADDRESS The value that appears by default is 192 168 1 19 LOCAL PORT it is the port where the Mother Board is going to get the information from the control computer In case of using SC Pascal it is necessary to write in this field the number port 1024 This port can be modified for those users who try to make and use their own editors and not SC Pascal HOST PORT it is the port where the control computer is going to get the information from the Mother Board In case of using SC Pascal the port used by default is 1026 This port must be opened without to be used for any other program and enabled opened in order the data can be received If the port 1026 is occupied it will be necessary to indicate another port which the user must choose e g 1036 The SC Pascal V5 Build 150 editor or Superior allows to the user to change the Host Port in the field List UDP Port In order the Board and SC Pascal are communicated the port indicated in the configuration page in the field HOST PORT and the port where SC Pascal listens which is indicated in List UDP Port must be the same 04 USER MANUAL da SIMCARD SC MB ETHERNET MAN US E RR 10 007 29 User Manual SimCard SC MB Ethernet Ed4 docx Flight Simulators CB www sismo soluciones com LP SOLUCIONES Plug amp Fly x Document 1 SC PASCAL Home Options 7 View Command Line W Enable
37. the new assigned IP address of the Mother Board must not be repeated in any other hardware or equipment of the network otherwise it will create conflict and will not load correctly Example 1 Before the control computer had the next IP address 192 168 2 200 2 We must remember that for acceding to the configuration page the IP of the control computer must have the same range that the Board Therefore proceed to change the IP address of the computer to 192 168 1 200 Go to the configuration page with the direction http 192 168 1 150 4 Change the default IP of the Mother Board to 192 168 2 150 bearing in mind that is not repeated by other one of the equipments that are used in the network 5 Change again the IP address of the control computer to the same one that the user had before 6 Go to the configuration page with the direction http 192 168 2 150 Watch video tutorials at the Technical Videos section of the main page of SISMO SOLUCIONES web w MASK in this section we advise to put the same number of mask that you have in the control computer of the network By default it is 255 255 255 0 DEFAULT GATEWAY it can be used to send information through Internet If you are not going to use it leave the value by default 192 168 1 1 UDP Config HOST IP it is the IP address of the control computer where the Mother Board will send all the information As already it has been mentioned the IP address of the compu
Download Pdf Manuals
Related Search
Related Contents
Proyector digital PB8253/PB8263 Serie Installation Hama 00131598 microphone 2015 Swimwear - Metro Swim Shop Universal Security Instruments USI-1204 Troubleshooting Guide Triptico Spintor platanera 10x21_NL.indd Catalogue Général - Lovibond Tintometer Hürner DataTrans für PocketPC CableWholesale 10W1-13306 power cable Original instructions centrifugalpump JCE Copyright © All rights reserved.