Home

E8000 SH7055 Emulator Diagnostic Program Manual

image

Contents

1. 9 Enter N RET to not load firmware LOAD FIRMWARE FILE OK Y N N RET file SHDCT761 SYS 10 Enter N RET to not load the LOAD ITRON DEBUGGER FILE OK Y N N RET ITRON debugger 12 Operations Display Message 11 Enter Y RET to allow the LOAD DIAGNOSTIC FILE OK Y N 2 Y REI diagnostic program file INPUT COMMAND B A DIAG SYS RET DIAG SYS to be loaded Then enter the parallel transfer command comPLETED to load DIAG SYS in the current directory on the PC to the emulator flash memory 12 Enter DIR RET to check whether FM DIR RET the necessary files have been FILE ID STATUS loaded SYS OK CONF OK LAN NO FIRM OK TRON NO DIAG OK INI OK MON OK 13 Enter Q RET to terminate the FM Q RET flash memory management tool START E8000 S START E8000 F FLASH MEMORY TOOL L SET LAN PARAMETER T START DIAGNOSTIC TEST S F L T 14 Installation is completed 13 4 2 I Operation Procedure Correctly connect the following components e E8000 emulator and personal computer RS232C interface e E8000 emulator and EV chip board when the E8000 EVCHIP test is selected For other components check connection according to the user system configuration Remove the EV chip board from the user system Turn on the following power supplies e Personal computer e E8000 emulator For other co
2. 6 2 Testing Circuit for SERIAL I F Test TESTOS onto the serial interface connector on the E8000 emulator before executing the diagnostic program Perform the following operations while executing the serial interface test Operation Procedures for TEST08 SERIAL I F TEST 1 Before executing the diagnostic program install the RS232C loop connector as shown in figure 4 2 2 Enter Y to the following message at diagnostic program initiation RS232C LOOP CONNECTOR EXIST Y N Y RET 3 When the diagnostic program is executed the serial interface test will be executed without operator interventions If no error occurs the following message is displayed TESTO8 SERIAL I F TEST COUNT 001 OK 17 P1284 loop connector Must be connected to the bidirectional parallel ger interface connector on the E8000 station for TESTO7 ua P directional parallel interface cable 5 Serial interface cable Personal computer DOS V machine RS232C loop connector Must be connected to the serial interface connector on the E8000 station for TESTO8 E8000 station Figure 4 2 Loop Connector Installation 9 For executing the operation tests TEST12 To execute the operation tests operator interventions are required during diagnostic program execution Perform the following operations while executing the operation tests Operation Procedures for TEST12 DIP SWITCH TEST 1 Enter Y to the fo
3. TRACE TEST OK TEST24 ERAM TIME MEASURE TEST COUNT 001 SUBROUTINE TIME MEASURE TEST1 O SUBROUTINE TIME MEASURE TEST2 SUBROUTINE TIME MEASURE TEST3 TIME STUMP TEST A to B TIME MEASURE TEST EST25 ERAM PARALLEL MONITOR TEST COUNT 001 OK EST26 INROM WRITE PROTECT TEST COUNT 001 OK TEST27 COVERAGE TEST COUNT 001 1 COVERAGE MEMORY R W TEST OK 2 PC COVERAGE TEST OK EST28 RESERVE COUNT 001 TEST29 RESERVE COUNT 001 TEST30 RESERVE COUNT 001 EST31 RESERVE COUNT 001 EST01 FLASH MEMORY READ TEST COUNT 002 a b c 1 MONITOR SUM CHECK OK d O O 0 9 OO N NN KR NN XN td o lt LJ LJ LJ NNN NN D D D D E Description a Test item number b Testitem c Execution count d Test result 22 Section 5 Error Handling If an error occurs provide a Hitachi sales agency with a detailed description of the problem 23 Section 6 Testing Circuits and Connectors 6 1 Testing Circuit for P1284 I F TEST TEST07 Connect the testing circuit that forms the loop in figure 6 1 to the bidirectional parallel interface connector on the E8000 emulator BUSY P AUTOFD N SELECT P SELECTIN N ACR N STROBE N PERROR P INIT N Figure 6 1 Testing Cir
4. 1 SF Always necessary Host interface software IPW included Printer Optional DOS aa EE Serial interface cable RS232C Device control board Bidirectional parallel interface cable P1284 Trace cahles coaxial cables EV chip board System floppy disk Figure 2 1 Test System Configuration Section 3 Diagnostic Program Function 3 1 General Description The diagnostic program has three test system configurations E8000 ONLY test and E8000 EVCHIP test which are independent E8000 emulator system tests and E8000 EVCHIP FIXED USER test Note that the E8000 EVCHIP FIXED USER test cannot be executed for it is the E8000 emulator system test at shipment and needs an additional system for testing Before executing an independent E8000 emulator system test remove the EV CHIP BOARD from the USER SYSTEM and USER SYSTEM INTERFACE CABLE Correct test results cannot be obtained when the E8000 emulator is still connected to the user system Independent E8000 Emulator System Test E8000 ONLY The system configuration shown in figure 2 1 is used for testing the independent E8000 emulator system The test results are displayed on the personal computer display After start up the system enters an endless test loop without operator intervention until an error is detected When an error occurs and ERROR CONTINUE is not specified the test is terminated If ERROR CONTINUE is specified the test resumes execution after
5. 11 4 1 Installation Procedure To execute the diagnostic program file DIAG SYS must be installed in the E8000 emulator flash memory If the E8000 emulator is connected to the host computer via the bidirectional parallel interface the diagnostic program can be loaded with the following procedure Note that the system disk is assumed to be inserted in drive A of the host computer It takes approximately one minute Operations Display Message 1 Initiate the E8000 system floppy disk IPW 2 Power on the E8000 emulator 3 Emulator monitor command prompt START E8000 S START E8000 F FLASH MEMORY TOOL 01 SET LAN PARAMETER T START DIAGNOSTIC TEST S F L T _ 4 Enter F RET to initiate the flash S F L T E RET memory management tool The FM emulator displays prompt FM and waits for a flash memory management tool command 5 Enter SL RET to load the system FM SL RET program ui 6 Enter 1 RET to select PC as the SELECT LOAD No 1 PC or 2 WS 1 RET host computer type and 2 RET to SELECT INTERFACE 1 RS 232C or 2 PARALLEL 2 2 RET select parallel interface as the interface method 7 Enter N RET to not load system LOAD E8000 SYSTEM FILE OK Y N N RET program E8000 S YS 8 Enter N RET to not load LOAD CONFIGURATION FILE OK Y N N RET configuration file SHCNF761 SYS
6. 3 P 36 PERIPHERALLOGICHIGH 10 SD4 P 19 to 35 GND 26 E
7. 5 Specify the test condition When the diagnostic program is loaded and the following message is displayed on the personal computer select the desired test conditions 15 Test Condition Specifications Please key in TEST PARAMETER OPERATION TEST EXECUTE Y N N RET a ERROR CONTINUE Y N 2 N RET b TEST MODE SELECT 1 E8000 ONLY 2 E8000 EVCHIP 3 E8000 EVCHIP FIXED USER TEST MODE 1 2 3 2 RET c DEVICE TYPE SH7055 RS232C LOOP CONNECTOR EXIST Y N 2 N RET d PARALLEL LOOP CONNECTOR EXIST Y N N RET e OPTION LAN BOARD EXIST Y N N RET f START Y N Y RET g Description a Only for tests requiring operator intervention Enter Y to execute the operation tests b c d e f g 6 Otherwise enter N Y Test continues when an error occurs N Test stops when an error occurs 1 Independent E8000 emulator system test 2 E8000 emulator device control board and EV chip board test 3 E8000 emulator system test at shipment cannot be used Enter Y to execute the serial interface test Otherwise enter N Enter Y to execute the bidirectional parallel interface test Otherwise enter N Enter Y to execute the optional LAN board test Otherwise enter N The test starts by entering Y If N is entered the diagnostic program main title wi
8. A A ee eee 1 Section ACONMSULANIOM ei i ets ee ets ea 2 241 Test System CODIIPUEFaHOD id dee tsar dis etat aa aa dd SR Up dd EE ERR eileen 2 Section 3 Diagnostic Program Funetion 4 3 1 General Description sitno A spa a de pio assa CA haee a e diaca ARA Died WSU MON Si a EQ ed ni eae Ra IE ag 6 323 Operation Flowchart sere pna e or e REA VR SER AN IRE a 8 3 4 Data Outputto Uie Printer esos ago o o p oa oA aac Eme ea Coe a ded den 9 Second Procedures i opa OD Wn as tr SS apa nanda 11 4 A lnstallanon Procedute s asse gee tou tee peti eb ea ale ri e fede Rie Dra ob e 12 4 2 Operation Procedure oes oret e poete e ee aede epe tee enisi UA pa RAS Pee 14 Section 5 Error Handling ioo pmo ete poete 23 Section 6 Testing Circuits and Connectors 24 6 1 Testing Circuit for P1284 I F TEST TEST 07 cce 24 6 2 Testing Circuit for SERIAL I F TEST TEST 08 cessere 24 6 3 Serial Interface COBTIgCIOE o c oos tore penne do e ordre XR cotas ER BPe Sele dun 25 6 4 Bidirectional Parallel Interface Connector esee 26 Section 1 Overview 1 1 Purpose This diagnostic program is used to automatically troubleshoot and maintain an SH7055 E8000 emulator hardware system The diagnostic program is on a 3 5 inch floppy disk HS7055EDD81SF When an error occurs execute the diagnostic program according to section 4 Diagnosti
9. BREAK TEST ERAM software break test X O TEST22 COMPULSORY BREAK TEST CBR register break test X O TEST23 ERAM TRACE TEST ERAM trace mode test X O TEST24 ERAM TIME MEASURE TEST Time measurement function check X O TEST25 ERAM PARALLEL MONITOR ERAM parallel monitor test X O TEST TEST26 INROM WRITE PROTECT TEST INROM write protect test X O TEST27 COVERAGE TEST COVERAGE RAM read write test X O Notes O Executed without operator intervention A Executed when specified X Not executed Note If an error occurs and ERROR CONTINUE is not specified displays an error message stops test execution and displays the following message Retry Y N If Y is entered retests the test item wherein the error occurred If N is entered displays the following message Continue Y N If Y is entered quits testing the test item wherein the error occurred and goes on to the next test item If N is entered displays the following message Abort Y N 2 If Y is entered resets the system softvare If N is entered returns to the first message Retry Y N 2 and repeats the above procedure until Y is entered 3 3 Operation Flowchart Figure 3 1 shows the diagnostic program operation flowchart Load diagnostic program E 8000 emi arar oniy E8000 EVCHIP FIXED USER E8000 ONLY or E8000 EVOHIP e system The user cannot perform this test configuration Specify test conditions Initiate diagnostic program TESTO1 TEST25 Fi
10. E8000 station and connected to LAN when performing the LAN board optional test 3 2 Test Items Test items are listed in table 3 1 The test items to be executed depend on the test system configuration Table 3 1 Diagnostic Program Test Items Executed or Not E8000 E8000 No Test Item Description ONLY EVCHIP TESTO1 FLASH MEMORY READ TEST Control board flash memory test O O TESTO2 CONT WORK RAM TEST Control board work RAM test O O TESTO3 SHARED RAM TEST Trace board RAM test O O TESTO4 FIRM RAM TEST Firmware RAM test O O TESTOS OPTION I F TEST Optional host computer I F DPRAM test O O TEST06 LAN I F TEST LAN board interface test A A TESTO7 P1284 I F TEST Bidirectional parallel interface test A A TEST08 SERIAL I F TEST Serial interface test A A TEST09 JTAG TEST JTAG controller test O O TEST10 CONT REG TEST Control board register test O O TEST11 IDR READ E8000 hardware configuration check O O TEST12 DIP SVVITCH TEST Control board DIP switch test A A TEST13 TRACE REG TEST Trace board register test O O TEST14 TRACE RAM TEST Trace board RAM test O O TEST15 PARALLEL RAM TEST Parallel RAM test O O TEST16 EBOX TEST DCONT firmware and ID check X O TESTA ERAM WINDOW TEST ERAM read write test X O TEST18 ERAM STEP TEST ERAM step test X O TEST19 ERAM HARD BREAK TEST1 ERAM hardware break test X O TEST20 ERAM HARD BREAK TEST2 ERAM hardware break test X O TEST21 ERAM SOFT
11. ENANCE PROGRAM DIAG SYS Version No x xx mm dd yyyy x xx indicates the version number Copyright C Hitachi Ltd 1997 Please key in TEST PARAMETER OPERATION TEST EXECUTE Y N 2 N ERROR CONTINUE Y N 2 N TEST MODE SELECT 1 E8000 ONLY 2 E8000 EVCHIP 3 E8000 EVCHIP FIXED USER TEST MODE 1 2 3 2 DEVICE TYPE SH7055 RS232C LOOP CONNECTOR EXIST Y N N PARALLEL LOOP CONNECTOR EXIST Y N N OPTION LAN BOARD EXIST Y N N START Y N Y TESTO1 FLASH MEMORY READ TEST COUNT 001 1 MONITOR SUM CHECK OK 2 SYSTEM SUM CHECK OK 3 EVCHIP FIRM SUM CHECK OK 4 CONFIG SUM CHECK OK 5 T M SUM CHECK OK 6 LAN SUM CHECK NO LAN FILE 7 ITRON SUM CHECK NO TRON FILE TESTO2 CONT WORK RAM TEST COUNT 001 1 PAUSE TEST OK 2 MARCHING TEST OK TESTO3 SHARED RAM TEST COUNT 001 1 PAUSE TEST OK 2 MARCHING TEST OK TESTO4 FIRM RAM TEST COUNT 001 1 PAUSE TEST OK 2 MARCHING TEST OK TESTO5 OPTION I F TEST COUNT 001 1 DPRAM PAUSE TEST OK 2 DPRAM MARCHING TEST OK 20 Diagnostic Program Output Example E8000 EVCHIP Test cont ESTO9 JTAG TEST COUNT 001 OK TEST10 CONT REG TEST COUNT 001 OK EST11 IDR READ TEST C
12. OUNT 001 ID CODE FCFE PC I F BOARD DISCONNECT TRC BOARD CONNECT DCONT BOARD CONNEC EVCH BOARD CONNECT LAN BOARD DISCONNECT EST13 TRACE REG TEST COUNT 001 OK EST14 TRACE RAM TEST COUNT 001 1 PAUSE TEST OK 2 MARCHING TEST OK TEST15 PARALLEL RAM TEST COUNT 001 1 PAUSE TEST OK 2 MARCHING TEST OK TEST16 EBOX TEST COUNT 001 1 EBOX ID CODE OK 2 EBOX ID CHECK OK 3 SHARED RAM TEST OK 4 WORK RAM TEST OK 5 ULSR TEST OK 6 MAPR R W TEST OK TEST17 ERAM WINDOW TEST COUNT 001 1 ERAM WINDOW TEST OK 2 ERAM WP TEST OK 3 ERAM GDD TEST OK 4 INROM READ WRITE TEST OK EST18 ERAM STEP TEST COUNT 001 OK TEST19 ERAM HARD BREAK TESTI COUNT 001 1 UBC HARDBREAK TEST OK 2 CHA0 7 HARDBREAK TEST OK 3 CHB0 7 HARDBREAK TEST OK 4 CHCO 7 HARDBREAK TEST OK TEST20 ERAM HARD BREAK TEST2 COUNT 001 1 SEQUENTIAL BREAK TEST OK 2 RAR OVERFLOW BREAK TEST OK 3 CHC TIMEOUT BREAK TEST OK 4 CHBO INTERRUPT TEST OK EST21 ERAM SOFT BREAK TEST COUNT 001 OK EST22 COMPULSORY BREAK TEST COUNT 001 OK TEST23 ERAM TRACE TEST COUNT 001 1 SUBROUTINE TRACE TEST OK 21 Diagnostic Program Output Example E8000 EVCHIP Test cont RANGE TRACE TEST SUBROUTINE RANGE TRACE TRACE STOP TEST TRACE SPECIAL CONDITION TEST T I Ij H EST RACE SUPPRESS TEST NRAM TRACE TEST RAM CONTINOUS ACCESS TEST ERAM PC
13. To all our customers Regarding the change of names mentioned in the document such as Hitachi Electric and Hitachi XX to Renesas Technology Corp The semiconductor operations of Mitsubishi Electric and Hitachi were transferred to Renesas Technology Corporation on April 1st 2003 These operations include microcomputer logic analog and discrete devices and memory chips other than DRAMs flash memory SRAMs etc Accordingly although Hitachi Hitachi Ltd Hitachi Semiconductors and other Hitachi brand names are mentioned in the document these names have in fact all been changed to Renesas Technology Corp Thank you for your understanding Except for our corporate trademark logo and corporate statement no changes whatsoever have been made to the contents of the document and these changes do not constitute any alteration to the contents of the document itself Renesas Technology Home Page http www renesas com Renesas Technology Corp Customer Support Dept April 1 2003 24 N SAS Renesas Technology Corp E8000 SH7055 Emulator Diagnostic Program Manual HS7055TM81HE A Cautions Hitachi neither warrants nor grants licenses of any rights of Hitachi s or any third party s patent copyright trademark or other intellectual property rights for information contained in this document Hitachi bears no responsibility for problems that may arise with third party s rights including intellectual property rights i
14. an error content display When initiating the diagnostic program select whether to execute the following tests Operation tests Serial interface test Bidirectional parallel interface test LAN board optional test Test of E8000 Emulator SH7055 Device Control Board and SH7055 EV Chip Board E8000 EVCHIP The system configuration shown in figure 2 1 is used for testing the E8000 emulator and the SH7055 device control board and SH7055 EV chip board for the E8000 emulator The test results are displayed on the personal computer display After start up the system enters an endless test loop without operator intervention until an error is detected When an error occurs and ERROR CONTINUE is not specified the test is terminated If ERROR CONTINUE is specified the test resumes execution after an error content display When initiating the diagnostic program select whether to execute the following tests Operation tests Serial interface test e Bidirectional parallel interface test e LAN board optional test Notes 1 To stop diagnostic program execution press the CTRL C keys and interrupt the test 2 The Bidirectional parallel interface and serial interface tests require additional circuits Prepare the necessary circuits according to the diagrams in section 6 Testing Circuits and Connectors before selecting the Bidirectional parallel interface and serial interface tests 3 The LAN board must be installed in the
15. c Program Operation Procedure Notes 1 This diagnostic program is not capable of finding all failures possible to occur in the E8000 emulator If execution results of the diagnostic program indicate a failure in the E8000 emulator inform a Hitachi sales agency of the test results in detail Hitachi makes no warranties for an E8000 emulator that has been taken apart repaired or remodeled by the user based on the test results of the diagnostic program In addition to this diagnostic program run the emulator internal system test described in section 5 Troubleshooting in the E8000 SH7055 Emulator User s Manual HS7055EDD81HE Section 2 Configuration 2 1 Test System Configuration Components required for diagnostic program execution are shown in table 2 1 and the test system configuration is shown in figure 2 1 Table 2 1 Test System Components Components Remarks E8000 emulator HS8000EST02H Control board Alvvays necessary HS8000PWB81H Device control board Always necessary HS7055EDD81H Trace board Always necessary HS8000PVVB82H PC I F board Always necessary HS8000PWB85H LAN board HS7000ELNO1H or HS7000ELNO2H Depends on user system configuration EV chip board HS7055EBK81H Always necessary Serial interface cable RS232C Always necessary Bidirectional parallel interface cable P1284 Optional Personal computer DOS V machine Always necessary System floppy disk HS7055EDD8
16. cuit for P1284 Loop Back Test 6 2 Testing Circuit for SERIAL I F TEST TEST08 Connect the testing circuit in figure 6 2 to the serial interface connector on the E8000 emulator Emulator Personal computer NC NC Figure 6 2 Testing Circuit for SERIAL I F Test 24 6 3 Serial Interface Connector Figure 6 3 shows pin locations in the serial interface connector on the E8000 emulator Table 6 1 lists the signal name of each pin SERIAL Figure 6 3 Pin Locations in E8000 Emulator Serial Interface Connector Table 6 1 Pin Signal Names in E8000 Emulator Serial Interface Connector Pin No Signal Name Pin No Signal Name 1 and 9 NC 5 GND 2 RXD 6 DSR 3 TXD 7 RTS 4 DTR 8 CTS 29 6 4 Bidirectional Parallel Interface Connector Figure 6 4 shows pin locations in the bidirectional parallel interface connector on the E8000 emulator Table 6 2 lists the signal name of each pin PARALLEL FE IITSOSS V 181716151413121110 9 8 7 6 5 4 3 2 1 i 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 Figure 6 4 Pin Locations in E8000 Emulator Bidirectional Parallel Interface Connector Table 6 2 Pin Signal Names in E8000 Emulator Bidirectional Parallel Interface Connector Pin No Signal Name Pin No Signal Name 1 BUSY P 11 SD5 P 2 SELECT P 12 SD6 P 3 ACK N 13 SD7 P 4 FAULT N 14 INIT N 5 PERROR P 15 STROBE N 6 SDO P 16 SELECTIN N 7 SD1 P 17 AUTOFD N 8 SD2 P 18 HOSTLOGICHIGH 9 SD
17. dicates the file name Note When selecting drive a insert the floppy disk in the floppy disk drive before executing this command Execute the diagnostic program Press the CTRL C keys after executing the diagnostic program Enter the following command to return to the monitor command input wait state gt q RET Enter the following command in the monitor command input wait state to terminate data output to the file gt RET Printing Open the file TM LOG to which the diagnostic program execution results were output and output the data to a printer from the personal computer used The file can be opened from the existing editor of the personal computer used 10 Section 4 Procedures This section describes the diagnostic program operation procedure ZA ui Always switch OFF all devices before connecting or disconnecting the E8000 EMULATOR and OTHER DEVICES Failure to do so will result in a FIRE HAZARD and will damage the E8000 emulator and other devices or will result in PERSONAL INJURY Notes 1 To execute the diagnostic program DIAG SYS must be installed in flash memory according to the instructions in the E8000 SH7055 Emulator User s Manual HS7055EDD81HE 2 Before executing the diagnostic program make sure the DIP switches have the same settings as at shipment refer to figure 4 1 3 When using the PCIF interface execute the diagnostic program from HDI Figure 4 1 DIP Switch Setting at Shipment
18. gure 3 1 Diagnostic Program Operation Flowchart Note TESTO6 is executed when the optional LAN board test is specified TESTO is executed when the Bidirectional parallel interface test is specified TESTO8 is executed when the serial interface test is specified TEST12 is executed when the operation tests are specified TEST16 to TEST25 are not executed when the E8000 ONLY test is selected 3 4 Data Output to the Printer The following describes the process for sending diagnostic program execution results to the printer using the E8000 emulator Diagnostic Program Output to Printer START E8000 S START E8000 F FLASH MEMORY TOOL L SET LAN PARAMETER T START DIAGNOSTIC TEST S F L T gt a TM LOG RET a S F L T t RET b Diagnostic program execution CTRL C c gt g RET d E8000 MONITOR HS8000ESTO2SR Vn m Copyright C Hitachi Ltd 1995 Licensed Material of Hitachi Ltd TESTING RAM 0123 START E8000 START E8000 FLASH MEMORY TOOL SET LAN PARAMETER START DIAGNOSTIC TEST S F L T gt RET e Ret Hm Notes 1 Underlined sections should be entered by the user 2 RET RETURN key Description a b c d e f Enter the following command after the emulator monitor command prompt Xa TM LOG RET In the above example a indicates drive a and TM LOG in
19. ll be displayed again Execute the diagnostic program using the procedure shown in figure 3 1 Execute each test item following the diagnostic program specifications OK is displayed if a test is executed with no errors An example of the E8000 EVCHIP test is shown on pages 18 to 20 16 7 For executing the bidirectional parallel interface test TES TO To execute the bidirectional parallel interface test install the P1284 loop connector described in section 6 1 Testing Circuit for P1284 I F Test TESTO onto the bidirectional parallel interface connector on the E8000 emulator before executing the diagnostic program Perform the following operations while executing the bidirectional parallel interface test Operation Procedures for TESTO7 P1284 I F TEST 1 Before executing the diagnostic program install the P1284 loop connector as shown in figure 4 2 2 Enter Y to the following message at diagnostic program initiation PARALLEL LOOP CONNECTOR EXIST Y N 2 Y RET 3 When the diagnostic program is executed the bidirectional parallel interface test will be executed without operator interventions If no error occurs the following messages are displayed TESTO7 P1284 I F TEST COUNT 001 FIFO R W TEST OK PARALLEL INTERRUPT TEST OK For executing the serial interface test TEST08 To execute the serial interface test install the RS232C loop connector described in section
20. llowing message at diagnostic program initiation OPERATION TEST EXECUTE Y N Y RET 2 When the diagnostic program is executed the E8000 emulator will halt at the following message and wait for command input TEST12 DIP SWITCH TEST COUNT 001 DIPSW 1 2 0092 DIPSW 1 2 H 5555 SET OK Y N 3 After setting the DIP switches as shown in figure 4 3 1 enter Y 4 If no error occurs the following message is displayed DIPSWITCH 1 2 H 5555 5555 OR 5 The E8000 emulator will halt again at the following message DIPSW 1 2 H AAAA SET OK Y N 6 After setting the DIP switches as shown in figure 4 3 2 enter Y 18 7 Ifno error occurs the following message is displayed DIPSWITCH 1 2 H AAAA AAAA OK 8 The E8000 emulator will halt again at the following message DIPSW 1 2 0092 SET OK Y N 9 After setting the DIP switches as shown in figure 4 3 3 enter Y 10 If no error occurs the following message is displayed DIPSWITCH 1 2 0092 0092 OR TEST END Note RET RETURN key 1 DIP switch setting 5555 Figure 4 3 DIP Switch Settings 19 Diagnostic Program Output Example E8000 EVCHIP Test E8000 EMULATOR TEST amp MAINT
21. mponents supply an appropriate voltage according to the user system configuration Start up the host interface software IPW on the personal computer After the host interface software IPW is initiated the E8000 emulator executes a self diagnostic test which checks the internal RAM and the registers while displaying the starting message shown on the following page For details refer to section 5 Troubleshooting in the E8000 SH7055 Emulator User s Manual HS7055EDDS81 HE 14 E8000 Emulator Starting Message EMULATOR INTERFACE HS8000EIWOI1SF Vn m Copyright C Hitachi Ltd 1996 Licensed Material of Hitachi Ltd E8000 MONITOR HS8000ESTO2SR Vn m Copyright C Hitachi Ltd 1995 Licensed Material of Hitachi Ltd TESTING RAM 0123 START E8000 S START E8000 F FLASH MEMORY TOOL L SET LAN PARAMETER T START DIAGNOSTIC TEST S F L T I Notes 1 Underlined sections should be entered by the user Both uppercase and lowercase letters are acceptable 2 RET RETURN key 4 Load the diagnostic program according to the following procedure Loading Diagnostic Program START E8000 S START E8000 F FLASH MEMORY TOOL L SET LAN PARAMETER T START DIAGNOSTIC TEST S F L T T RET E8000 EMULATOR TEST amp MAINTENANCE PROGRAM DIAG SYS Version No x xx mm dd yyyy Copyright C Hitachi Ltd 1998
22. n connection with use of the information contained in this document Products and product specifications may be subject to change without notice Confirm that you have received the latest product standards or specifications before final design purchase or use Hitachi makes every attempt to ensure that its products are of high quality and reliability However contact Hitachi s sales office before using the product in an application that demands especially high quality and reliability or where its failure or malfunction may directly threaten human life or cause risk of bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support Design your application so that the product is used within the ranges guaranteed by Hitachi particularly for maximum rating operating supply voltage range heat radiation characteristics installation conditions and other characteristics Hitachi bears no responsibility for failure or damage when used beyond the guaranteed ranges Even within the guaranteed ranges consider normally foreseeable failure rates or failure modes in semiconductor devices and employ systemic measures such as fail safes so that the equipment incorporating Hitachi product does not cause bodily injury fire or other consequential damage due to operation of the Hitachi product This product is not designed to be radiation resistant No one is
23. ncludes but is not limited to use in life support systems Buyers of this emulator product must notify the relevant Hitachi sales offices before planning to use the product in such applications Improvement Policy Hitachi Ltd including its subsidiaries hereafter collectively referred to as Hitachi pursues a policy of continuing improvement in design performance and safety of the emulator product Hitachi reserves the right to change wholly or partially the specifications design user s manual diagnostic program manual and other documentation at any time without notice Target User of the Emulator Product This emulator product should only be used by those who have carefully read and thoroughly understood the information and restrictions contained in the user s manual Do not attempt to use the emulator product until you fully understand its mechanism It is highly recommended that first time users be instructed by users that are well versed in the operation of the emulator product LIMITED WARRANTY Hitachi warrants its emulator products to be manufactured in accordance with published specifications and free from defects in material and or workmanship Hitachi at its option will repair or replace any emulator products returned intact to the factory transportation charges prepaid which Hitachi upon inspection shall determine to be defective in material and or workmanship The foregoing shall constitute the sole remedy for a
24. ny breach of Hitachi s warranty See the Hitachi warranty booklet for details on the warranty period This warranty extends only to you the original Purchaser It is not transferable to anyone who subsequently purchases the emulator product from you Hitachi is not liable for any claim made by a third party or made by you for a third party DISCLAIMER HITACHI MAKES NO WARRANTIES EITHER EXPRESS OR IMPLIED ORAL OR WRITTEN EXCEPT AS PROVIDED HEREIN INCLUDING WITHOUT LIMITATION THEREOF WARRANTIES AS TO MARKETABILITY MERCHANTABILITY FITNESS FOR ANY PARTICULAR PURPOSE OR USE OR AGAINST INFRINGEMENT OF ANY PATENT IN NO EVENT SHALL HITACHI BE LIABLE FOR ANY DIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE OR LOSSES OR EXPENSES RESULTING FROM ANY DEFECTIVE EMULATOR PRODUCT THE USE OF ANY EMULATOR PRODUCT OR ITS DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES EXCEPT AS EXPRESSLY STATED OTHERWISE IN THIS WARRANTY THIS EMULATOR PRODUCT IS SOLD AS IS AND YOU MUST ASSUME ALL RISK FOR THE USE AND RESULTS OBTAINED FROM THE EMULATOR PRODUCT II State Law Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may have other rights which may vary from state to state The Warranty is Void in the Following Cases Hitachi
25. permitted to reproduce or duplicate in any form the whole or part of this document without written approval from Hitachi Contact Hitachi s sales office for any questions regarding this document or Hitachi semiconductor products IMPORTANT INFORMATION READ FIRST READ this user s manual before using this emulator product e KEEP the user s manual handy for future reference Do not attempt to use the emulator product until you fully understand its mechanism Emulator Product Throughout this document the term emulator product shall be defined as the following products produced only by Hitachi Ltd excluding all subsidiary products Emulator station Device control board e EV chip board The user system or a host computer is not included in this definition Purpose of the Emulator Product This emulator product is a software and hardware development tool for systems employing the Hitachi microcomputer HD64F7055 hereinafter referred to as SH7055 By exchanging the device control board and EV chip board this emulator product can also be used for systems using Hitachi microcomputers supported by other E8000 series emulators This emulator product must only be used for the above purpose Limited Applications This emulator product is not authorized for use in MEDICAL atomic energy aeronautical or space technology applications without consent of the appropriate officer of a Hitachi sales company Such use i
26. product safely at your own risk IH SAFETY PAGE READ FIRST READ this user s manual before using this emulator product e KEEP the user s manual handy for future reference Do not attempt to use the emulator product until you fully understand its mechanism DEFINITION OF SIGNAL WORDS DANGER indicates an imminently hazardous situation which if not avoided will result in DEATH or SERIOUS INJURY to you or other people WARNING indicates a potentially hazardous situation which if not avoided could result in DEATH or SERIOUS INJURY to you or other people CAUTION indicates a hazardous situation which if not avoided may result in minor or moderate injury to you or other people or may result in damage to the machine or loss of the user program It may also be used to alert against unsafe usage NOTE emphasizes essential information N WARNING Observe the precautions listed below Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST Carefully handle the emulator product to prevent receiving an electric shock because the emulator product has a DC power supply Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance 2 Always switch OFF the emulator product and the user system before connecting or disconnecting any CABLES or PARTS 3 Always befo
27. re connecting make sure the connection direction is correct Supply power according to the power specifications and do not apply an incorrect power voltage Use only the provided AC power cable Use only the specified type of fuse Warnings on Emulator Usage Warnings described below apply as long as you use this emulator Be sure to read and understand the warnings below before using this emulator Note that these are the main warnings not the complete ZN WARNING Always switch OFF the emulator and user system before connecting or disconnecting any CABLES or PARTS Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST ZN WARNING Place the emulator station and EV chip board so that the trace cables are not bent or twisted A bent or twisted cable will impose stress on the user interface leading to connection or contact failure Make sure that the emulator station is placed in a secure position so that it does not move during use nor impose stress on the user interface i E Preface Thank you for purchasing the E8000 emulator for Hitachi s original microcomputer SH7055 The diagnostic program automatically checks whether the E8000 emulator is operating correctly Read this manual and understand it before using the diagnostic program Contents Section T Overview a GES SS GES tedni 1 dunes ss ES tes
28. shall have no liability or legal responsibility for any problems caused by misuse abuse misapplication neglect improper handling installation repair or modifications of the emulator product without Hitachi s prior written consent or any problems caused by the user system All Rights Reserved This diagnostic program manual and emulator product are copyrighted and all rights are reserved by Hitachi No part of this diagnostic program manual all or part may be reproduced or duplicated in any form in hard copy or machine readable form by any means available without Hitachi s prior written consent Other Important Things to Keep in Mind 1 Circuitry and other examples described herein are meant merely to indicate the characteristics and performance of Hitachi s semiconductor products Hitachi assumes no responsibility for any intellectual property claims or other problems that may result from applications based on the examples described herein 2 No license is granted by implication or otherwise under any patents or other rights of any third party or Hitachi Figures Some figures in this diagnostic program manual may show items different from your actual system Limited Anticipation of Danger Hitachi cannot anticipate every possible circumstance that might involve a potential hazard The warnings in this diagnostic program manual and on the emulator product are therefore not all inclusive Therefore you must use the emulator