1. Operating Voltage DC 12V 10 Lock Output Load Max 3A User Capacity 2000 Alarm Output Load Max 20A Card Reading Distance 5 6 cm Operating Temperature 45 C 60 C Active Current lt 60mA Operating Humidity 10 90 RH Idle Current 25 5 mA Adjustable Door Relay time 0 99 seconds Adjustable Alarm Time 0 3 minutes Wiegand Interface Wiegand 26 bit Wiring Connections Electric Lock Exit Button External Alarm External reader 6 Installation Remove the back cover from the keypad using the normal screw driver Drill 2 holes on the wall for the Self tapping screws and 1 hole for the cable 7 Wiring Put the supplied rubber bungs to into the two holes Fix the back cover firmly on the wall with 2 Self tapping screws Thread the cable through the cable hole Attach the keypad to the back cover Colour Function Description Green DO WG output DO White D1 WG output D1 Grey ALARM Alarm negative alarm positive connected 12 V Yellow OPEN Exit button one end the other end connected GND Brown D IN Magnetic switch one end the other end connected GND Red 12V 12V DC Regulated Power Input Black GND 12V DC Regulated Power Input Blue NO Relay normally on end Connect positive electric lock Purple COM Relay Public end connect GND Orange NC Relay Closed end connect negative electric lock common power supply diagram
2. To delete All users To delete ALL users Note that this is a dangerous option so use with care 2 0000 To unlock the door For a PIN user Enter the PIN then press E For a card User Read card For a card and PIN user Read card then enter PIN 11 2 Door Settings Relay Output Delay Time Master code E 4 0 99 Af To set door relay strike time 0 99 is to set the door relay time 0 99 seconds Door Open Detection Door Open Too Long DOTL warning When used with an optional magnetic contact or built in magnetic contact of the lock if the door is opened normally but not closed after 1 minute the inside buzzer will beep automatically to remind people to close the door and continue for 1 minute before switching off automatically Door Forced Open warning When used with an optional magnetic contact or built in magnetic contact of the lock if the door is forced open or if the door is opened after 20 seconds the inside buzzer and alarm output will both operate The Alarm Output time is adjustable between 0 3 minutes with the default being 1 minute To disable door open detection Factory 6 Lo default To enable door open detection le 31 L8 Alarm output time c1 5 0 3 8
3. Open the door Bright Di Alarm Bright E 7 Alarm 11 Detailed Programming Guide Master code 11 1 User Settings 999999 is the default factory master code To enter the programming mode To exit from the programming mode Note that to undertake the following programming the master user must be logged in To change the master code 0 New code H New code The master code can be 6 to 8 digits long Setting the working mode Set valid card only users 0 Entry is by card only 3 Set valid card and PIN users EN Bl Entry is by card and PIN together 3 2 4 Entry is by either card or PIN default Set valid card or PIN users To add a user in either card or PIN mode i e in the 8 2 mode Default setting To add a Pin user 1 User ID number PIN Ej The ID number is any number between 1 amp 2000 The PIN is any four digits between 0000 amp 9999 with the exception of 1234 which is reserved Users can be added continuously without exiting programming mode as follows 1 User ID no 1 PIN User ID no 2 PIN To delete a PIN user 2 User ID number E Users can be deleted continuously without exiting programming mode ID number
4. Old PIN New PIN New PIN To change the PIN of a PIN user This step must be done out of programming mode To add a card user Method 1 11 Read card This is the fastest way to enter cards Cards can be added continuously without exiting user ID number auto generation programming mode To add a card user Method 2 This is the alternative way to enter cards using User ID Allocation In this method a User ID is allocated to a card Only one user ID can be allocated to a single card 1 ID number Read card User can be added continuously without programming mode exiting To add a card user Method 3 Card number is the last 8 digits printed on the back of the card user ID number auto generation 1 Card number W User can be added continuously without exiting programming mode To add a card user Method 4 In this method a User ID is allocated to a card number Only one user ID can be allocated to the card number 1 ID number Card number User can be added continuously without programming mode exiting To delete a card user by card Note users can be deleted continuously without e ReadCard exiting programming mode 2 LUser 1D To delete a card user by user ID This option can be u
5. To set the alarm output time 0 3 minutes Factory default is 1 minute Keypad Lockout amp Alarm Output options If there are 10 invalid cards or 10 incorrect PIN numbers in a 10 minute period either the keypad will lockout for 10 minutes or both the alarm and the inside buzzer will operate for 10 minutes depending on the option selected below Normal status No keypad lockout or 7 0 Factory default setting alarm factory default Keypad Lockout 7 1j Alarm and inside buzzer operate 7 2 To remove the alarm To reset the Door Forced Open warning Read valid card or Master Code Master Code To reset the Door Open Too Long warning Close the door or Read valid card o 12 The unit operating as a Wiegand Output Reader In this mode the unit supports a Wiegand 26 bit output so the Wiegand data lines can be connected to any controller which supports a Wiegand 26 bit input ALARM OPEN 12V GND NO Access Controller COM Connect 10
6. M BELLA 7 Pink rig BELL_B Pink cw md Bell CO 12v Power Supply Do Green D1 White ALARM Gray sv Alarm OPEN Yellow Exit button D IN Grom AD Door contact 12V Red GND Black F 2 d NO Blue Power on the lock keep unlocking COM Purple Power off the lock keep unlocking NC Orange pC D lt j i Connect special power supply diagram BELL_A Tfi Pink BELL B DO Green D1 ALARM OPEN D IN 12V GND NO COM NC Orange dien Connect 8 To Reset to Factory Default a Disconnect power from the unit b Press and hold key whilst powering the unit back up c On hearing two Di release key system is now back factory settings e o 8 go 29 2 5 an g 5 z 2 Please note only installer data is restored user data will not be affected 9 Anti Tamper Alarm The unit uses a LDR light dependent resistor as an anti tamper alarm If the keypad is removed from the cover then the tamper alarm will operate 10 Sound and Light indication Operation Status Red Light Green Light Yellow Light Buzzer Power on Bright Di Stand by Bright Press keypad Di Operation successful Bright Di Operation failed DiDiDi Enter into programming mode Bright S x In the programming mode Bright Di Exit from the programming Bright s Di mode
7. CAMEL SECURITY SHENZHEN CAMEL SECURITY CO LTD Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit www camelsecurity com CAMEL SECURITY YOUR TRUSTED SECURITY SYSTEM SUPPLIER 1 Packing List Name Quantity Remarks Keypad 1 User manual 1 Rubber plug 2 6mmx30 mm used for fixing Self tapping screws 2 04mmx28 mm used for fixing 2 Quick Reference Programming Guide To enter the programming mode Master code W 999999 is the default factory master code To exit from the programming mode Note that to undertake the following programming the master user must be logged in To change the master code O New code ff Newcodel The master code can be 6 to 8 digits To add a PIN user User ID number PIN E The ID number is any number between 1 amp 2000 The PIN is any four digits between 0000 amp 9999 with the exception of 1234 which is reserved Users can be added continuously without exiting programming mode To add a card user 1 Read Card E Cards can be added continuously without exiting programming mode To delete a PIN or a card user 2 User ID number Hj for a PIN user or 2 Read Card for a card user Users can be deleted continuously wit
8. hout exiting programming mode To unlock the door for a PIN user Enter the PIN then press K To unlock the door for a card user Present the card 3 Description The unit is single door multifunction standalone access controller or a Wiegand output keypad or card reader It is suitable for mounting indoor This unit supports up to 2000 users in either a Card 4 digit PIN or a Card PIN option The inbuilt card reader supports 125KHZ EM cards The unit has many extra features including lock output current short circuit protection Wiegand output and a backlit keypad These features make the unit an ideal choice for door access not only for small shops and domestic households but also for commercial and industrial applications such as factories warehouses laboratories banks and prisons 4 Features Plastic case Full programming from the keypad 2000 uses supports Card PIN Card PIN Can be used as a standalone keypad Backlight keys Wiegand 26 input for connection to external reader Wiegand 26 output for connection to a controller Adjustable Door Output time Alarm time Door Open time Very low power consumption 30mA Fast operating speed 20ms with 2000 users Lock output current short circuit protection Easy to install and program Built in light dependent resistor LDR for anti tamper Built in buzzer Red Yellow and Green LEDS display the working status 5 Specifications
9. sed when a user has lost their card Card number To delete a card user by card number This option can be used when the user want to make the change but the card has lost 2 Note users can be deleted continuously without exiting programming mode To add a card and PIN user in card and PIN mode 3 1 To Add a card and Pin user The PIN is any four digits between 0000 amp 9999 with the exception of 1234 which is reserved Add the card as for a card user Press to exit from the programming mode Then allocate the card a PIN as follows Read card 1234 PIN 9 PIN To change a PIN in card and PIN mode Read Card Old PIN New PIN New PIN Z Method 1 Note that this is done outside programming mode so the user can undertake this themselves To change a PIN in card and PIN mode ID number Old PIN New PIN New PIN Method 2 Note that this is done outside programming mode so the user can undertake this themselves To delete a Card and PIN user just delete the card 2 User ID To add a card user in card mode B 0 8 To Add and Delete a card user The operating is the same as adding and deleting a card user ing 2 amp
Download Pdf Manuals
Related Search
Related Contents
User Manual - AV-iQ MANUALE DI INSTALLAZIONE Dataflex Combo M5 Monitor Keyboard Mount 422 VOIZZE 330 Symetrix 450-manual Manual dos Trabalhos de Laboratório Multi-Link Multi-Link TeleVoIP Stick Cordless Telephone User Manual César doit mourir Smeg GKC64-3 Instructions for Use Manual del servicio de certificación con clave pública para el Copyright © All rights reserved.