1. 6 Installing the 7 7 CONNOTA M 7 Connections and operating conditions 9 10 1 Choosing a mode ssessesssseeee eene nnne nne nennen nnn 10 Conng raton tatto ime od in ues etu NEU den daa e eS 10 Table of command and configuration 5 16 Setting the device through a computer 17 Ligeti i HOO NG HN T n 23 futurel USER MANUAL 1539 1 Important information Please carefully read the information in this manual before attempting to operate the device in order to protect yourself and use the equipment properly This device shall be exclusively utilized for its intended use In no event shall the company Futura Elettroni Ca or its dealers be held responsible for any damage either extraordinary incidental or indirect of any nature financial physical etc arising from the possession use or failure of this product In case of changes to the device tampering or non compliance with the instructions in this manual the warranty will be null and void The device contains highly integrated components that
2. E futurel 21 USER MANUAL HONICA Enabling the Status Monitoring you can control in real time the room temperature the system sen ses the min and max registered values the thresholds for the set temperatures and information regar ding the active alarm 14 27 15 Cracker isl 143217 Mander di tala 1432 1 amp Mantar di Rates Avot Porta COMIS Aperta 6600 4181 Dispostive rilevata e J LOG Esteso Unit di Telecontrollo Mostra sempre in primo piano Pressing Activate Extended Log it is possible to visualize in a specific window all data in transit through the communication port 232421234565 22 USER MANUAL TEX139 About Configuratore TDG E The software version can be seen pressing on the menu bar Version 1 0 0 0 Copyright 2010 Futura Elettronica Software di configurazione per le unit di telecontrollo GSM ll software viene fomito gratuitamente da Futura Elettronica e non necessita di alcun tipo di attivazione Ne vietata la divulgazione ad uso Important Management via SMS is disabled when the TDG139 is 2 connected to the computer 14 Troubleshooting The following table presents all possible solutions to some problems that may arise Problem Possible reason Solution Green LED LD5 is off No supply tension or inver Check power supp
3. 8 Start up You must first obtain a valid SIM Card from a GSM network provider Use a common mobile phone to disable the SIM Card PIN To do so check the manual of the mobile If the SIM Card PIN is not disabled the device cannot work as it cannot connect to the GSM network Before feeding the TDG139 please insert the SIM Card into the SIM Card holder mind the orientation making sure it is correctly blocked then connect the antenna cable to the connector Now connect the power supply 9 Configuration The device can be set as follows EASY SETUP Configuration through call PROFESSIONAL SETUP Configuration through SMS Computer SETUP Configuration through PC connection it needs a USB interface code FT782M available separately 1 EASY SETUP Configuration through call made on start up When the device is supplied with power LD5 will immediately flash at 1 Hz frequency The TDG139 will try to connect to the GSM network when connected LD5 will briefly flash every 2 seconds or so After the system initialization which may take several se conds the device alternately illuminates the yellow LEDs LD3 and LD4 to indicate futurel i TDG139 USER MANUAL the configuration call on hold which should take place within 3 minutes If during this time the unit receives a call it stores the caller s number that number will be enabled to manage all the available functions in the first memory locati
4. Command THI xxxxxxxxxxxx sets the message the remote sends to the numbers in the list enabled to receive alarm SMS in case the maximum temperature threshold is exceeded ALLMAX xxxxxxxxxxx is the message you want to write 100 charac ters max including spaces The semi colon is not accepted letters must all be capitalized The default phrase is ALARM TEMPERATURE THRESHOLD EXCEEDED Example How to set the alarm message MAXIMUM THRESHOLD EXCEEDED THI MAXIMUM THRESHOLD EXCEEDED Command TLO xxxxxxxxxxxx sets the message the remote sends to the numbers in the list enabled to receive alarm SMS in case the minimum temperature falls under the threshold ALLMIN xxxxxxxxxxx is the message you want to write 100 charac ters max including spaces The semi colon is not accepted letters must all be capitalized The default phrase is ALARM TEMPERATURE THRESHOLD EXCEEDED Example How to set the alarm message MINIMUM THRESHOLD EXCEEDED futurel 15 TDG139 USER MANUAL TLO MINIMUM THRESHOLD EXCEEDED As already mentioned at the beginning of Chapter 11 the system accepts messages with multiple commands separated by a comma helping the user save time and money There follows that the system replies to certain commands with more than one SMS This can be avoided by means of a command placed at the beginning of the SMS sent to the TDG139 Command RISP at the beginning of a multiple message disables all reply mess
5. on the log window 18 3 20 UX Peete CUM 14 acest con sce 27 Miis eeu A i ei Porta TOMIS Aperta Gee USER MANUAL Su FUTURA ETTHONICA Master Las ruri Masi es nite alterna died era di beleconimlio Su numer consentita l accesso completo gaben incur a funzione aula cera uicit Pos Humero hirina Menig du FUTURA ELETTHONICA Maner da Masc ativi altera del aloe di neat USER MANUAL In the Information tab you can find the IMEI and the firmware version of the connected device in order to modify the access password stored in the device type in the fields Old and New the desired password and press To access the system and make all possible settings please type the current password in the field System password then press Confirm If the device does not re ply to the commands sent from the computer make sure the password stored in the PC is the same as the one specified in the management program Management of phone numbers enabled to control the device is done through the folder Telephone Numbers It is possible to store or delete enabled numbers and to request the full list visible on the right of the window of those numbers in the device Every selected operation Store Delete or Request Full List must b
6. requests the set hysteresis value to the device The alarm can be generated by the presence of tension on the opto isolated input IN2 as well as when the room temperature is out of the parameters previously set by means 12 futurel USER MANUAL 1539 of these commands Command ALLMIN yxx defines the minimum threshold of the thermal alarm in the place of y place the sign or for positive or negative temperature xx is the abso lute value in two digits keeping in mind it is possible to set values between 10 and 99 14 210 2 F Example How to set a minimum threshold of 5 23 F ALLMIN 05 Command ALLMAX yxx defines the maximum threshold of the thermal alarm in the place of y place the sign or for positive or negative temperature xx is the absolute value in two digits keeping in mind it is possible to set values between 10 and 99 C 14 210 2 F Example How to set a maximum threshold of 30 C ALLMAX 30 Note In the last two examples the remote will start the alarm sequence for temperatu res under 5 C 23 F and over 30 C 86 F Please note that by default and also after a full reset no values are defined and the thermal alarm is disabled it is possible to set only one value but in this case the alarm goes off only when trespassing that threshold Command ALL requests the device the values of the thermal alarm temperature Example ALL Command ALL OFF disarm
7. that is SMS with more than one command in order to save money commands must be separated by a comma Of course a multiple com mand will produce several answer messages in order to disable this you can disable the reply by adding at the beginning of the multi command SMS the string RISP see the description of this command Here we present and describe all commands that can be sent to the device via SMS Note every command must be written without spaces Command PWDxxxxx pwd changes the password xxxxx is the new password nu meric five digits pwd is the current password the default password is 12345 Example 54321 as the new password and 12345 as the current password PWD54321 12345 Note The password is required Command NUMx 39nnnnnnnnnnn pwd stores a phone number up to 8 numbers 19 digits each in the device x is its position in the list nnnnnnnnnn is the phone number with country code 39 for Italy pwd is the current password Example How to enter number 3498911512 in the 8th position NUM8 393498911512 12345 Note The password is required only if you try to save the number in a position alre ady occupied by another one or when the command is sent from a phone that is not in the list If the command is sent from an unknown phone the password is always 10 futurel USER MANUAL 1539 required Command NUMx pwd removes a phone number from the list x is its position in the list pwd is the current p
8. the operation Check that the mobile used for the configuration has an active ID i e the hidden call or private cal has not been enabled To return to the standard configuration with active ID please refer to the mobile instructions manual To check your own mobile configuration simply call another mobile The caller ID is active if it displays the number or name of the calling mobile NOTE Yellow LEDs LD3 and LD4 lighten up alternately until the TDG133 is set up with a call within the first three minutes of start up If time is up and no configuration has been made the TDG133 turns off the two LEDs and waits for the configuration SMS The EASY SETUP mode can be restored by disconnecting and reconnecting the power supply you will have three minutes to set up the device 10 Connections and operating conditions The remote must be connected to the heating system as shown on Picture 2 The device can track the status of a power line as for example the one corresponding to the boiler alarm indicator however galvanically isolated from it Input IN2 must therefore be connec ted in parallel to the light bulb of the boiler that indicates the block when doing the wiring work make sure the boiler alarm indicator is in low tension and the positive is connected futurel USER MANUAL 230 Boiler Power adaptor 230 5 Vdc min 600 mA min Picture 2 b NO j NO NOY Remote Qmm GND ac c
9. verify that a communication speed of 9600 Baud 8 1 is set Installing and using the software The software can be downloaded at www futurashop it from the page of the TDG139 In order to use the management software it is first necessary to install it Launch the Setup files and follow the installation instructions as they appear Once this is done start the program After this the window TDG Configurator appears on the screen through this window it is possible to modify all the settings of the device add users futurel 17 IDC2 I9 change the password etc It is an intuitive program and the graphic interface simplifies this procedure So as to use the available comman ds supply and connect the TDG139 to the computer then select the communication port COM top left created If need be with the Upda te button you can update the list related to the available ports in the computer Afterwards press Con nect to activate the connection and wait for the screen to update with all the data on the connected module From now on the TDG139 can be managed from your computer PC mode is shown by LD3 on If the device was connected to the computer before the storage of the first master number the message Waiting for Call for Master Num ber Storage will appear on the log window down In order to continue with the setting make the call so as to store the number The execution will be confirmed with a message
10. 0
11. Ej control Thermostat IN2 1424 Block light bulb to in input IN2 In this way if the system gets blocked due to an obstruction in the chim ney the excessive lowering of the fluid pressure in the radiators the lack of gas etc the system remotely communicates the anomaly with an alarm SMS or a call Please note that the alarm on the opto isolated input is valid only when the circuit is working in automatic mode A The open contact of the relay NO of OUT1 must be used to close the remote control of the boiler if the boiler is connected to its own thermostat disconnect and make the connections as shown above Connect the two wires of the thermostat to input IN1 of the board and outputs NO and C of the relay to the control of the boiler As for the existing thermostat in presence of a summer winter element please only consider the contact related to the boiler control not the cooling one If the thermostat only has one contact and it s an electronic one or if it has a summer winter selector it must be placed on winter snowflake symbol Once the system is done feed the unit with a power supply providing at least 9V 500 mA but also able to provide current peaks of about 1A The device can also register the tempe rature in the room it is installed with the help of a very precise probe the DS1820 useful for the thermal alarm function that informs the user if the maximum threshold is exceeded or if itlowers beyond t
12. ICH A RINGTONE IS SENT VOCxxxxxxxx ON OFF All active ALWAYS AUTOMATICALLY SEND SMS ON START UP 0 1 automatic sending x 0 disables sending of SMS ALARM MODIFY TEXT FOR ALARM TEMPERATURE EXCEEDS MAX beoe TEMPERATURE THRESHOLD 100 characters max THRESHOLD EXCEEDED ALARM MODIFY TEXT FOR ALARM TEMPERATURE EXCEEDS MIN TIO TEMPERATURE THRESHOLD 100 characters max THRESHOLD EXCEEDED MODIFY TEXT FOR ALARM BOILER INPUT IN PRESENCE OF TENSION 100 characters TIN2XXXXXXXXX ALARM INPUT MODIFY TEXT FOR START UP MESSAGE 100 characters max SYSTEM START UP only sent to first number stored Phone call to the remote number RISP at the beginning of the message REQUEST TEMPERATURE TEMP command DISABLE REPLY FOR MULTIPLE MESSAGE 13 Setting the device through a computer By means of a computer with a specific software and USB interface code FT782M op tional installed directly on the board it is possible to interact with the device so as to easily modify all programming and function settings but specially and also to make the initial setting before installing in the room where it should work The use of a computer allows you to save the time and money needed for a full con figuration via SMS which even by means of multiple messages shall be slow and expensive it is also useful when you want to check all settings without requesting them with a SMS After starting the software
13. The device is meant for operation in clean and dry rooms Do not expose the device to heavy vibrations not use the device in presence of flammable gases vapors or dust The device can only be repaired by a qualified technician When repairing the unit original parts must be used The use of differing spare parts can cause serious material loss or personal injury the tracks connecting the relay contacts to the terminal are sized considering a load activation which absorbs 10 A for short periods of time 5 Operation of the device The TDG139 is a GSM remote control system easy to install and simple to use the device allows you to remotely manage via specific SMS the heating in a home or office and also to control the temperature of the room where it is installed simply by calling the phone number of the SIM Card in the device The unit also functions as a remote alarm it has an opto isolated input tension level that can be connected to the boiler malfunction indicator and set to suit different operating conditions so as to send a warning if it receives more that the threshold voltage by doing so if the system gets blocked due to an obstruction in the chimney the excessi ve lowering of fluid pressure in the radiators the lack of gas etc the system remotely communicates the anomaly via an alarm SMS or a phone call The system also includes a thermal alarm triggered when the temperature in the room exceeds the limit s
14. USER MANUAL 139 706139 GSM Temperature control Technical data e GSM GPRS Module SIM900 Quad 850 900 1800 1900 MHz GPRS multi slot class 10 8 GPRS mobile station class B Output power Class 4 2 W 850 900 MHz Class 1 1 W 1800 1900 MHz GSM external stylus antenna Temperature excursion probe 55 to 99 67 to 210 F device 10 to 55 14 to 131 F 1 input logic level IN1 controlled by the NO contact of the external thermostat 1 alarm input opto isolated logic level IN2 boiler al arm blocked 1 relay output to control low tension loads SELV type 60 Vdc manageable in Automatic Manual or Slave to the external thermostat Max current relay contacts 10 A Operation setting via SMS local button and computer Power supply 9 to 32 Vdc stabilized or with Li lon battery 800 1 000 mA h dle current 50 mA idle peak up to 1A Dimensions 103x67x28 LxWxH mm Complies with EN 60950 1 2006 EN 301489 7 V 1 3 1 EN 301511 V9 0 2 future TDG139 USER MANUAL 10 11 12 13 14 TABLE OF 5 Important information 3 Ns SNS WIC ION ETE 9 General information Em 4 NERO ETE aa E rroia 4 Operation of the device seeesssssssssessseseeeeeene nennen nennen nnns 5 Connectors and LEDS T
15. ages Example How to disable the answer message related to the sent commands RISP OUT ON TRES INT 10 12 Table of command and configuration SMS FUNCTION DEFAULT VALUE PWD REQUIRED PASSWORD PWD 12345 PASSWORD REPLACEMENT PWDxxxxx 12345 12345 ALWAYS wUMn 392229876643 12845 Pasion s DELETE A NUMBER NUMx 12345 ALWAYS CHECK STORED NUMBERS NUM 12345 ALWAYS FULL RESET OF ALL PARAMETERS RES ALWAYS RELAY ACTIVATION IN BISTABLE MODE OUT ON Relay idle RELAY DEACTIVATION IN BISTABLE MODE OUT OFF Relay idle RESET STATUS AFTER BLACK OUT RIPx 0 1 active restoring x 0 relay disabled after black out REQUEST RESTORING FUNCTION STATUS RIP SET FUNCTIONING MODE FUN X A Thermostat Automatic M Manual REQUEST FUNCTIONING MODE FUN REQUEST TEMPERATURE TEMP RESET MIN AND MAX TEMPERATURES TRES SET TEMPERATURE TO BE MAINTAINED 00 99 NOR XX 22 SET HYSTERESIS ON TEMPERATURE IST X 0 5 REQUEST THE SET HYSTERESIS VALUE IST pcc iin ALLMIN yxx fel p 4 di em ALLMAX yxx REQUEST ALARM TEMPERATURE ALL ENABLE TEMPERATURE ALARM ALL ON 16 futurel USER MANUAL TEX 137 FUNCTION ETTM DEFAULT VALUE PWD REQUIRED DISABLE TEMPERATURE ALARM ALL OFF INHIBITION TIME TEMPERATURE ALARM 00to 59 min INT mm 5 INHIBITION TIME BOILER INPUT 00 59 min INC mm 5 SET THE NUMBERS TO WHICH SMS ARE SENT SMSxxxxxxxx ON OFF All active ALWAYS SET THE NUMBERS TO WH
16. arly the power supply ones have to be checked regularly for fractures or damage of the isolation shield If cables are visibly damaged the device has to be switched off immediately until they have been repla ced Strictly comply with the technical specifications of components or modules used with this device If the information contained herein and or the information on the com ponents or modules used with the device are not clear enough please contact a future TDG139 USER MANUAL qualified technician e Before starting the device carefully check whether it is suitable for the intended field of application In case of doubt please contact a qualified technician or the Manufac turer Dealer e The Manufacturer Dealer cannot be held responsible for improper handling or wrong connections therefore it cannot be held responsible for any damage that may result e Devices that operate with lt 35 Volts must be connected by a qualified technician e Before starting the device check there is no current leakage in the housing 3 General information For EU residents Environmental information related to this product This symbol on the device or package indicates it is forbidden to dispose of the product in the environment at the end of its lifecycle as it could be harmful for the environment itself Do not dispose of the product or batteries if used as unsorted waste For more information about the recycling of this product pl
17. assword Example How to delete the 4th phone number from the stored list NUM4 12345 Note The password is required Command NUM pwd requests the list of phone numbers currently stored in the device pwd is the current password Example NUM 12345 Note The password is required Command RES pwd restores the initial settings default of the system also the stored phone numbers are deleted pwd is the current password Example RES 12345 Note The password is required RL1 can be managed any time no matter the chosen functioning mode Command OUT ON activates the output relay if idle Example How to activate the output relay OUT ON Command OUT OFF disables the output relay if idle Example How to disable the output relay OUT OFF Command OUT requests the output relay status of the remote Example OUT In case of black out command RIPx stores the relay status and restores it when power is back on x has a value of 1 to enable restoring O to disable it The default value is 1 Example How to enable the relay status recovery on start up RIP1 Example How to disable the relay status recovery on start up RIPO Command RIP requests the current setting for the relay status recovery Example RIP futurel 11 TDG139 USER MANUAL Command FUN x remotely sets the functioning mode of the device x can have the following values e T enslaved mode RL1 follows the external thermostat e A automat
18. can be damaged by 4 electrostatic discharge Therefore do not touch any metal part tracks com ponent terminals etc with your hands Only handle the device by the edges in order to avoid touching the components the board Notice The user who makes the module operational by adding further components or by put ting it into a housing is seen as a manufacturer and is obliged to hand out all the ne cessary technical documentation as well as place his name and address on the device Products made with this equipment have to be considered as industrial products from the safety perspective The phone costs related to sending SMS generated by the device are charged on the SIM in the device 2 Safety instructions In accordance with the current regulations on safety whenever using a device under tension all necessary precautions shall be taken The device must always be AN installed in absence of tension The device must placed into suitable housing before use Du ring the installation the device must not be connected to the power source or to other devices Before handling the device or opening the container where it has been placed unplug the power connector and make sure the circuit is not live Before working with any kind of tool on the device make sure it is disconnected from the power supply and that components that store energy capacitors are discharged All cables connected to the device particul
19. e confirmed by pres sing futurel il Penta Aperta Pera BsudRae bea 3600 _ nfornazon amen 4 Teteleee Usete Sart Scheda TDG123 IMEI prz OO T4 20 orm Finirai Vescha 12145 hun TENS di acres per Piper Def suit Herra sacas ale cursor ob abies 14 28 5E Pieza ner mermerirta sone numer Master 3 devono cones in coe 133 T Concerti Porta COMIS Aperta GST Deae Peacou COMM Numer d Telelonc Avvisi ingressi Unete Hurai Mater Memerrin Cancella Hume Lats Compliance Conlermane la lecanone TT TDG139 FUTURA TETTRONICA Rumen Maser ats cen casted Facil er often die d beleconimillo Sg inspaosttree nlevate e connesse ELETTHONICA Maser Lain des eet Hail er alien del aaier d Selecantrolio Su questi numer conaertits F acoeaso eomplelo al nduss Ia Sencancallo uicit del eT Afenaione se gid presente un numere nella posizione indicata questo verr scerarcmtto con rgmern 16 22 Po
20. ease contact the city hall your local waste disposal service or the shop where it was purchased 4 Operating conditions Warning before making connections to the device carefully verify that the supply ten sion and the tension applied to the inputs correspond to those described in this manual Important information e The device must be installed in compliance with the current safety standards e Supply the device only with stabilized DC tension between 9 and 32 Vdc to be ap plied to the power plug see Picture keeping in mind the polarity center positive Use a safety current limited power supply providing current of at least 500 mA that is also able to cope with absorption peaks of 1A A The power cable must not exceed 3 meters he relay outputs in the device can only be used to control low tension loads SELV type 60 Vdc The switching current on the relays must not exceed 10 A The container used to house the device must have adequate ventilation holes The device can work in any position eCheck that the section of the cables used is enough USER MANUAL 1539 The operating temperature of the device ranges between 10 C 55 C 14 F 131 F elf moisture condensation occurs wait for at least 2 hours before starting the equip ment the device away from flower vases sinks water pipes etc Protect the device from moisture spray water and heat
21. en input Pressing P1 once again takes the unit back to Automatic A mode After 10 seconds being inactive the chosen mode is automatically applied Note If the circuit remotely through SMS receives the order to set a mode different from the one set locally with button P1 the order is a priority i e the phone command as well as he computer one cancels P1 command 11 Configuration SMS Commands and settings can be sent from any mobile via SMS as long as the message includes the password essential to ensure the setting cannot be made by outsiders To speed up certain commands it is possible for the device to store 8 numbers ena bled to send commands without the password The numbers in the list are the same to which if enabled the device will send SMS or ringtones to indicate an alarm situation However there is a series of sensitive functions that no matter who sends the SMS still need a password In particular functions that add or remove other numbers from the list that change the current password or request the list of approved numbers As a result of a command or query the device replies with an execution confirmation SMS or a SMS with information about the settings Please note that all commands that do not require a password are effective only if they come from a recognized phone that is a phone which number is in the list of those stored in the remote an outsider needs a password The remote accepts multiple SMS
22. et by the user i e it exceeds an upper limit or falls below the mini mum one as the one connected to the boiler indicator the thermal alarm may cause the sending of SMS or calls The circuit can store up to eight phone numbers to send alarms in the form of text messages or simple calls those numbers are also approved to manage certain functions of the device without using a password In order to quickly set the module it is also possible to use a computer with the special TDG Configurator software connected via USB code FT782M to be installed directly on the board of TOG Io USER MANUAL the device The device needs an active SIM Card from any GSM network provider using GSM 1800 MHz networks When using a prepaid SIM Card always check the available credit so that the device can send a reply message to any possible command if the function has been enabled 6 Connectors and LEDs As shown in figure 1 the TDG139 remote control has a 7 pin terminal to connect con tacts NC NO and C of its relay OUT1 and input terminals INT RELAY and IN2 LED Connect the supply tension between 9 and 32 Vdc of the device to the outlet marked PWR center positive Via USB optional directly installed on the board you can connect a computer with the special TDG Configurator software it is possible to make all programming and function setting as well as visualize information regarding the connection and the temperature values regis
23. he minimum set threshold As the one connected to the boiler indicator the thermal alarm can determine the sending of SMS or phone calls The circuit can store up to eight phone numbers to which send alarms as SMS or simple calls During the first start up unless the unit has been reset the TDG139 works by default in Automatic A mode i e it activates the relay when the sensed temperature in the room is under the one set by the user subtracted to the value defined as hysteresis default is 0 5 C 32 9 F For example if the temperature to maintain is 22 C 71 6 F and hysteresis is 0 3 C 32 54 F the relay operates at 21 7 71 06 F 22 0 3 This condition is shown by the turning on of the yellow LED LD4 10 1 Choosing a mode Locally by pressing a button you can sequentially define a different mode By pressing P1 till the LEDs flash rapidly you can enter the functioning mode then by pressing P1 again it goes from automatic mode to the Forced M one where RL1 is always active until disabled via SMS or mode is changed the condition is shown by the turning on of LD3 and LD4 By pressing the button one more time you access the Enslaved T mode shown by the future TDG139 USER MANUAL turning on of LD3 only here the circuit follows the pattern of the thermostat connected to input IN1 i e the relay clicks closes C on NO if the input is shorted or remains idle in the opposite case op
24. ic mode M the relay is forced active Example How to set the enslaved mode FUN T Note The set mode is stored and a possible black out does not change it The default setting is A Command FUN requests the current functioning mode to the device Example FUN The remote control has a function related to the sensed room temperature CURRENT MIN and MAX Command TEMP requests the current value of the room temperature as well as the stored MIN and MAX values Example TEMP Note It is also possible to obtain the temperature without sending any SMS You just need to call de device with a phone number in the list and then hang up the unit will send a message with the requested data Command TRES resets the MIN and MAX temperature values registered Example TRES Command NOR xx sets the room temperature the remote must maintain when fun ctioning in automatic mode xx is the desired temperature value for instance 24 in Celsius default 22 C 71 6 F Example How to set a 25 C 77 F NOR 25 Command IST x sets the value of threshold between 0 1 and 0 9 C 32 18 33 62 F x is the desired hysteresis and can have a value between 1 and 9 1 for 0 1 C 9 for 0 9 C Note The default value is 0 5 C 32 9 F Example How to set the relay intervention when the room temperature drops by 0 4 C 32 72 F in relation to the temperature value to be maintained 23 C 73 4 F IST 4 Command IST
25. ime it is supplied 14 futurel USER MANUAL 139 Command AVVx enables or disables the sending of a SMS during start up x has a value of 1 to enable it O to disable it The default value is O Example How to enable the start up SMS AVV1 Example How to disable the start up SMS AVVO Command TSU xxxxxxxxxxxx sets the message of the text the remote sends during start up is the text you want to write 100 character max including spaces The semi colon is not accepted letters must all be capitalized The default phrase is SYSTEM STARTUP Example How to set the start up message DEVICE TDG139 ACTIVE TSU DEVICE TDG139 ACTIVE Regarding the activity on input IN2 it is possible to set the notification message corre sponding to the presence of tension Command TIN xxxx defines the message the device sends to the numbers in the list enabled to receive alarm SMS when input IN2 is alerted on the presence of tension is the message you want to write 100 characters max including spaces The semi colon is not accepted letters must all be capitalized The default message is INPUT ALARM Example How to set the alarm message BOILER BLOCKED when there is tension on IN2 TIN BOILER BLOCKED Messages for thermal alarm It is possible to individually define those that come from exceeding the upper threshold and from the falling of the temperature under the inferior threshold
26. ly cable ted polarity Green LED LD5 flashes cycli No GSM network available Change the position of the ex cally at 1 Hz frequency or signal intensity not enou ternal GSM antenna gh The device does not send Reply to the message with Do not use the RISP command a reply to the configuration command RISP is disabled in the SMS or recharge the SIM or there is no credit in the Card SIM Card During the first start up LEDS The device has already Completely reset the device and LD4 do not lighten been started using the RES command alternatively The device does not react to The mobile used for the call Enable the ID on outcoming the call from an enabled num has a hidden ID calls ber The device cannot engage in The PIN on the SIM Card Disable the PIN request from the GSM network has not been disabled the SIM Card The information in this manual is subject to change without notice Technical Assistance In case of technical problems or questions concerning the TDG139 a hotline is available Mon and Wed 2 pm 6 pm CET Central Europe Time Technical assistance 39 0331 245587 futurel 23 C 0051 Complies with all applicable european directives Produced and distributed by FUTURA ELETTRONICA SRL Via Adige 11 21013 Gallarate VA Tel 0331 799775 Fax 0331 792287 web site www futurashop it technical Information supporto futurel com futurel Relase 29 09 2010 V I 1 0 V F 2
27. on it turns the two LEDs off and becomes operative otherwise at the end of the interval it switches off the yellow LEDs and waits for the configuration SMS PROFESSIONAL SETUP mode 2 PROFESSIONAL SETUP Configuration through SMS executable at any time This mode takes full advantage of the device with operations as output switch mode and threshold setting inhibition time setting query room temperature query adding supplementary phone numbers to manage the device reception of alarm messages and ringtones in general it is used to set the TDG139 with all parameters via simple SMS A full reset to restore the default settings can also be made via SMS The syntax for all available commands can be found in Section 11 Configuration SMS 3 Computer SETUP Configuration through PC connection This mode allows you to quickly set up the TDG139 with no additional cost through a computer using a special software connected via USB code FT782M optional Chapter 13 provides all the necessary information to make the best use of this confi guration mode Configuration through call Turn on the device wait till the yellow LEDs LD3 and LD4 start to flash alternately then with the mobile used to control the TDG139 call the phone number corresponding to the SIM Card in the remote control The device will reject the call and store the caller number in the first memory location LD3 and LD4 will flash rapidly to indicate
28. ria COM TA success 16 22 21 Credenzad Depots E 19 USER MANUAL COMM UsudRate bee 9600 sonen irtomazers Names 8 Telefono Avs ingressi Uscte OTM Namet Fcenone SMS d Alame lista dei Master atthe aliriomo del d imm P Pos Pos 3 4 1 5 7 Numes Ricesione isnie d Mame The tab Notices is used to enable sees or disable numbers on specific po E Poo wn sitions in the list enabled to receive alarm SMS or calls gi 16 22 20 Pots 14 aperta con successo 16 22 21 Credenza 16 31 20 Memceuzanore numo beta Master inicemaseni Numer d SS 5 L amen eri Master Sae Sema ua E Rosine dei ruri aer riom del aaia idi teleconimlin ripiano stain gu mancanaa xd Humar Nominative The tab Outputs is used to enable dedii or disable the function Restore Prva r Relay Status in absence of tension E and directly manage the relay 01 20 USER MANUAL The text of
29. s the thermal alarm Example ALL OFF Command ALL ON sets the thermal alarm Example ALL ON It is possible to set an inhibition range for the thermal alarm useful when the TDG139 is used to control a room which thermal excursion varies slowly the range is also useful for instance when the user after receiving an alarm that states the room has cooled excessively remotely forces the heating In that case if you do not set an inhibition ran ge enough in order to give the heating system the time to raise the temperature beyond the threshold alarm the remote continues to send SMS and calls Command INT mm sets the inhibition range by thermal alarm detection mm are the minutes between 00 and 59 Example How to set a 10 minute range INT 10 Note The default value is 5 minutes futurel 13 TDG139 USER MANUAL Command INC mm sets the inhibition range by boiler block alarm detection during this intervention the IN2 status is not considered mm are the minutes between 00 and 59 Example How to set a 15 minute range INC 15 Note The default value is 5 minutes Below we present the commands used to set the numbers in the list to which the device will send the alarm SMS or calls in case of tension presence in the opto isolated input IN2 or when the room temperature is out of the set values Command SMSxxxxxxxx ON pwd defines the numbers to which the device sends a SMS in case of alarm x are the positions of the
30. stored phone numbers from 1 to 8 pwd is the current password Example How to enable the reception of alarm SMS for numbers 1 3 6 and 7 in the list SMS1367 0N 12345 Note By default all numbers in the eight positions of the list if they exist will receive a SMS in case of alarm Command SMSxxxxxxxx OFF pwd defines the numbers to which the device does not send a SMS in case of alarm x are the positions of the stored phone numbers from 1 to 8 pwd is the current password Example How to disable the reception of alarm SMS for numbers 2 4 8 and in the list SMS248 OFF 12345 Command VOOCxxxxxxxx ON pwd defines the numbers to which the device will send a ringtone in case of alarm x are the positions of the stored numbers from 1 to 8 pwd is the current password Example How to enable the reception of alarm ringtones for numbers 1 3 6 and 7 in the list VOC1367 0N 12345 Command VOCxxxxxxxx OFF pwd defines the numbers to which the device does not send a ringtone in case of alarm x are the positions of the stored phone numbers from 1 to 8 pwd is the current password Example How to disable the reception of alarm ringtones for numbers 2 4 8 and in the list VOC248 OFF 12345 Note Generally a call is quicker that a SMS for that reason this function can be very useful and cheaper since there is no need to answer the call The remote control sends a customizable SMS to the first phone number in the list every t
31. tered by the device Button P1 is used to choose one of the three available modes T Thermostat A Automatic M Manual Power supply USB interface connector PWR optional center positive SIM card slot 3 444488 8844 dodi d 1 ITE AT B SMA female connector for GSM antenna Picture 1 YP S vem 4444 lj BORN 022 200906101 QNSE 1 2164 LD1 LD3 LD4 LD5 C NO NC TEMPERATURE SENSOR futurel USER MANUAL 1339 Functions of the LEDs LD3 on T mode enslaved to the external thermostat the relay reproduces the state of the room thermostat LD4 on A automatic mode the relay status depends on the room temperature and on the settings set via SMS LD3 and LD4 both on M manual mode the relay is always active disregarding the rest of the settings LD3 LD4 also report a CONFIGURATION CALL on hold both LEDs turn on alternately after start up and without phone numbers stored in the list LD5 on receiving call flashing at 1Hz frequency relay research quick flash every two seconds hooked in the network LD1 on relay excited off relay unexcited 7 Installing the USB A special USB interface code FT782M availa ble separately must be installed on the remote control card as shown in the picture alongside the mini USB connector must be upwards
32. the notification SMS sent from the device after excee ding the min or max temperature threshold set after the boiler block or a black out can be defined by the user through the window SMS Text The folder Functioning gathers all settings that define the circuit configuration as the room tempe rature threshold the thermal alarm threshold and the inhibition ranges of the boiler input and the tempera ture alarm tomasen Numen d Telefono Teno SMS ala SMS Ranup Meddo E amp aves slave Destva avveso Testo SMS gt pL5ws Persone razone SMS d Teo SMS Temperatura supesor a soghe Massimo Testo SMS TDG139 Numen Master Saena Late des rumes Master ativi al rtemo del siema belecontiolio Su quest numer consentita l accesso completo af sutema indusa la funzione Agncancelio sula uscita Pos Numero Nominato Uscte Testa Sas Funzionamento Madaha d Frusenamenta pu Temperature Tenperdura da Manterare 19 Azreramerin Tempermume Mamme e Mame reme Tarpeia er Cim Temperatura x21 C Ema Terga dh riduce RA wait apoa 14 27 1 amp Crece Porta COMIS Aperta 9600811 Dispostive nieste e