1. 0 DIP 6 on Code on 1 DIP 6 Code AC aC PC6 EA fe With DT CAM wiring mode The audio door station DT595A can be extended an additional CCTV camera to be a video door station For more details about the camera please refer to DT CAM user instructions DT CAM ERL ba Felco PC6 Monitor iE Hala os Elim l lr ra Electric Lock Connection Door Lock Controlled with Internal Power 12 3 mm Connect one lock Jumper position in 2 3 Note 1 Electronic lock of Power on to unlock type Bus PL S2 S1 S1 should be used 2 The door lock is limited to 12V and holding current must be less than 250mA 3 The door lock control is not timed from Exit Button EB 4 The Unlock Mode Parameter of Monitor must be set to 0 by default Note 1 The external power supply must be used according to the lock 2 The jumper must be taken off before connecting 3 Setup the Unlock Mode of Monitor for different lock types Power on to unlock type Unlock Mode 0 by default Power off to unlock type Unlock Mode 1 POWER SUPPLY DIP Switch Setting The DIP switch is designed to set the code
2. 137 H x49 W x28 D mm Precaustions Please clean the unit with soft cotton cloth don t use the organic impregnant or chemical clean agent If necessary please use a little pure water or dilute soap water to clean the dust The unit is weather resistant However do not spray high pressure water on access control keypad directly Excessive moisture may cause problems with the unit e You must use the right adaptor which is supplied by the manufacture or approved by the manufacture Pay attention to the high voltage inside the products please refer service only to a trained and qualified professional Cable Requirements The maximum distance of the wiring is limited in the DT system Using different cables may also affect the maximum distance which the system can reach The farest monitor 1 I I monitor I I 1 I When Monitor quantity lt 20 Twisted cable 2x0 75 mm so 60 30 Twisted cable 2x1 mm so 80 40 When Monitor quantity gt 20 Twisted cable 2x1 mm Twisted cable 2x1 5 mm Note If the monitor has been specified the distance refer to the parameter 10 EAS The design and specifications can be changed without notice to the user Right to interpret and copyright of this manual are preserved DT ENG 595A V1 P120924
3. for door station and monitor there are two states for each DIP switch please refer to the following sketch map Door station DIP setting Total 3 bits can be configured bit 1 and bit 2 are used to assign ID code for door station bit 3 is used to match the video impedance The switches can be modified either before or after installation ID 0 00 set to the first door station ID 1 10 set to the second door station ID 2 01 set to the third door station ID 3 11 set to the fourth door station Note if the video impedance need to match please set the bit 3 on Indoor monitor DIP setting There are 6 bits in total The DIP switches are used to configure the user code for Monitors Bit 6 is an video impedance match switch which have to be set to ON if match the impedance otherwise set to OFF Bit 1 Bit 5 are used to set user code to DT595A door station the user code should set to 0 15 Please refer to the following settings 8 9 a a el code 7 code 12 code 13 code 14 Specification e Power Supply DC 24V e Power Consumption Standby 60mA Working status 200mA e Lock Power Supply 12Vdc 300mA Internal Power e Working Temperature 10 C 45 C e Wiring 2 wires non polarity Dimension
4. DEASY 2 Wire Video Intercom System CHL S Read this manual carefully before using the product and keep it well for future use Parts and Function The door station is an audio door station without camera which is designed for DT 2 wire system The front panel is made of zinc alloy for better protection against vandalism 8 cauterization and the call button is also made of zinc alloy with blue backlight for auxiliary illumination the unlock and talking LED indicator guarantee the door station working efficiently With the rainy cover the door station can be strongly protection against water Speaker Unlock Indicator Talk Indicator Front Panel Call Button a Microphone a Rainy Cover Terminal Description Connection line i SPK adjust DIP__ PROG 5 ON Do BUS Blue amp Green see 4 g IIO S2 Red FEJE 3 e o PL White u CALL button S1 Yellow S1 Black Lock Control Jumper to select the lock type Please refer to Electric Lock Connection DIP switch to set ID code for door station total 4 door stations can be supported Please refer to DIP Switch Setting SPK adjust to adjust the talk volume PROG button reserve CALL button press to call the user 4P terminal to update software via specified programmer Co
5. Z Str St Bus PLS2 SISt Bus PLSASIHSt eesscoo army pocos lepeece E AC saree DIP on off off ra B cD Celelelal uth DBC 4S PC6 vo EW gajan a ales 0 Impedance witch BUS Blue amp Green S2 Red PL White S1 Yellow S1 Black Multi Monitors Connection Basic IN OUT wiring mode 200202 AQUI UL UAOAL 123456 123456 123456 Code 0 DIP 6 off Code 1 DIP 6 off Code 14 DIP 6 off monitor i monitor ES monitor Te o o oo RR RR EXA D AC 5 Monitors Pe SN With DBC 4S Wiring Mode OFF ON dance itch de Impec swil 14 DIP 6 on Code 15 DIP 6 on Code DIP on off off 12 DIP 6 on Code 13 DIP 6 on Code Impi 2 DIP 6 on Code 3 DIP 6 on Code EI edance OFFON switch DIP on off off
6. nnection line to connect the bus line and the electronic locks BUS Blue amp Green connect to the bus line no polarity S2 Red the S2 connect with S1 to activate the relay of ERL to extend a camera of DT CAM 9090 4 please refer to DT CAM user instructions in details PL White external lock power input connect to the power positive power S1 Yellow lock power output S1 Black lock power output Unit Mounting The location of outdoor station should keep away from snow rain and intensity light Accessory contents Accessories include a screwdriver T20 one M4X10 screw two PA4X25 screws three PA3x25 screws three PM3x12 screws and five screw stoppers 6X30 Installation steps Installation height for door station usually is 145 160cm 1 Use screws to fix the back panel and rainy cover to the wall after connect the cable correctly 2 Attach the front panel to the back panel then use the screw to fix it Wiring and Connection Basic one to one connection Bus PL S2 S1 S1 ppooeel BUS Blue amp Green S2 Red PL White S1 Yellow S1 Black Multi Door Station Connection 4 Camera 3 Camera 2 Camera 1 Camera ID 00 ON ha Bus PLS2 SIHSI Bus PLS