Home

E.53.010SS01 说明书 小UPS英文中性350VA-1600VA

image

Contents

1. 12VDC UPS 24VDC UPS 7 Maintenance 7 1 Preventative Maintenance Preventive Maintenance ensuresthe longer Servicelife of UPS Please check the followingsteps every month 1 Turn offthe UPS 2 Make sure the airway not blocked 3 Make sure that the UPS surface is notcovered by dust 4 Check whether the input output and batteryconnecting lines are firm or not and the insulation is effective or not 5 Make sure that the UPS is not affected with damp 6 Turn on the UPS 7 Let the UPSwork in battery modefor about 5 minutesand inthis penod ifthere is no other alarmfrom the UPS thenthe UPS is normal if there is other alarm message please contact the local dealer for help Page 9 7 2 Battery Maintenance The UPS contains sealedlead acid maintenance free battery The badenvironment the high discharge frequency thehigh temperature etc will dramatically reduce the use life ofbattery Theuse life of batterywill also reduce evenit isnot used It is suggested to discharge the battery onceevery 3 months whenAC is normal The following is thesteps of how tocheck the battery whenthe battery is near the end of its life the battery will endin bad performance So please remember the following steps of checkingand maintenance 1 Connect the UPS toAC and turnon the UPS charge the battery forat least 10 hours noting the load status 2 Keep th
2. stem With AVR UPS Model 350VA 1600VA LINE INTERACTIVE UPS USER S MA 1 Remarks about Safety ca esa atau lav E ere saiaiaie Saya bier eiavas iarela niece 1 2 Working Principle 0eeceeeeeeeeeeeeeeeee eee ees 2 DA AC Noninaleiktsstisttenie aed cae theo necetiessncteatnaseaias 2 23 PC Pailipeetvsntesteatrentearseuscdacieniensosaaeneounsioreass 3 2 3 Batteryand Charginge sssseseereeeeeeeee erete 3 3 Main FOACUPeS 11 te tee eses codnssecesenecsscsessecsceanedessenns 3 3 1 Unattended Opetation sssssseseeessseeseeeeees 3 39 Dr eibeictig cet taaiiosiwains isse ets edna ainina 3 3 3 Interface POrte ss2 cee cee cee eee cee cee ccc ccc eeeeeeesseessee A 3 4 Three Kinds of Alarm Function sesssssesssssessse ses 4 3 5 Lock Phase Function ser cet cee tee cet tee tects cee cee 4 3 6 No load turn off function automatically 5 3 7 The Function of the Self set Frequency 5 4 Specifications eeeeeeeeeeeeeeeeeeeeee eee eeeseeeeees 5 5 Introduction Bee meee ne cec nce cee cen ene cec cee cee cee cee cee cen ces eee 6 5 1 Off line UPS LED lt sesscecceccecceccssscsscccscccsces 6 5 2 Offline UPS LCD ssssssssssssssssessssesoesssssesooseo 6 5 3 Outside UPSr eee cecce scence scence nccnccnccncccenanencsccscns 7 6 Installation and Operation 2ssesseeeees 7 6 1 Installation of Standard UPS essers sasssininesassns 7 6 2 Installat
3. 1600VA n xl xi xi xI Xi x2 XD long backup PF 0 6 when Input range 35 to 23 PF 0 45 Aee el Fuse in AC mode limited output currency in inverter mode protection Efficiency of oaa power gt 80 in inverter mode Remark Output and input voltage and frequency can be set according to customers requirements Page 5 5 Introduction 5 1 Off line UPS LED AC on indicator green when AC is normal Charging over load indicator orange 1 AC normal lights charging indicator light when battery capacity to 90 after the CPU out 2 If charging is normal but the light does not illume the light will indicate for low voltage of battery or overload Inverting indicator red AC fails or AC abnormal on and off switch 5 2 Off line UPS LCD Alarm indicator Hello Fes Battery capacity BGs BB load UPS output volatge UPS input voltage or freqency RS232 interface port CAUTION TEL MODEN FAX Output socket FUSE AC Input Page 6 5 3 Outside UPS AC on indicator green Charging indicator yellow Inverting indicator red UPS Switch Terminal of groundline input and outputAC Battery port connecting tooutside line Fuse Place for battery Name Power Batteryinside DC woltage CP150LH 350W 350W 100AH X2 24VDC CP150LH 400W 400W 100AH X2 24VDC 6 Installation and Operation 6 1 Installation forStandard UPS 1 Shut down the
4. OFF button on the front panel ispressed the UPS will not output voltage E It is forbidden to open thecase because there is danger with electricity If there is problem please handle with the instructionof experts E It is forbidden to put containercontaining liquid inside on the UPS becaus e it will cause danger of electric shock orfire when the UPS short circuits E Whenthe UPS isabnormal please cutoff power immediately and turn to experts or the dealer for help E A s there is nooverload protection of the UPS it can not be overload ed Othe rwise it would cause danger E It is strictly forbidden to placeand operate the UPS in the following environment Page l Place with inflammable gas or corrosivegas or much dust Place with very high temperature orvery low temperatu re above 40 C or below 0 C or high humidity above 90 Place with direct sunlight or nearheater Place with strenuous vibration Outside Mi Please use dry powder fire extinguisherin case of fire it is forbidden to use fluid fire extinguisher because it will causeelectric shock MThe mainssocket outlet thatsupplies the UPS shall beinstalled near the UPS and shall be easily accessible When the UPS power cord mustbe connected to an earthed mains socket outletfor safety reasons the UPS marking or installation instructions shall so state the same requirementfor marking applies to any special equi potential earth bonding to other connected UPSequi
5. e battery voltage drops tothe limited lowest voltage the inverter will turn offautomatically and protect thebattery WhenAC comes back UPSwill turn on automatically Page 3 E Battery over charge protection When in ACmode UPS automatically enterthe chargemode batterytesting system will automatically detect thebattery state of charge when battery fullcomplet ely the charge will beautomatically closed system toensure that the service life of batteries energy conservation WE Short circuit Protection when UPS is ininverter mode and there is shock or short circuit UPS will output limited currency protecting the UPS When in AC mode the UPS willbe protected first byinput fuse and thentransfers to the inverter working mode 3 3 Interface Port with function ofintelligent monitoring ofcomputer optional E This seres UPS can have DB9or USB interface port which can servicefor such systems as WINDOWS98 NT 2000 ME 2003 XP Vistaretc and keep files andmonitor UPS to turn off automatically E Automatically check AC normalor bad and the battery voltageand UPS data of the running E When AC fails the UPS will countdown to keep the files turn off the systems and shut down UPS automatically E The interface provides the function of predicatingand setting the time of uninterruptible power supply and record the UPS andAC status such as historical data E Display the countdown time of turnoff of the UPS E The interface can set the
6. e load atthat status and recordthe total power capacityof the load and then remove the nput plugof the UPS simulateAC failure and thebattery of the UPS will dischargeuntil turn offautomatically and record the discharge time Please keep the recordof the dischargetime for later check 3 The battery service lifeis about 2 to3 years in normal conditions But in such condition as high temperatureor high discharge frequency the battery service life will reduce to about0 5 to 1 year 4 With the operatingtime passed the capabilityof battery will beweakened the discharge time willdecrease When the dischargetime is 80 of the initial discharge time the performance of the battery will be weakened fasterand accordingly thechecking frequency of thebattery shouldchange from once every half year to onceevery month 5 Servicing of batteries should be performed or supervised by personnel knowledgea ble about batteries and required precautions When replacing batteries replace withthe same type and number of batteries or battery packs CAUTION Do not dispose of batteries in a fire The batteries may explode CAUTION Do not open or mutilate batteries Released electrolyte is harmful to the skin and eyes It may be toxic 7 3 Handling ofabnormity The UPS can serveand provide protection tousers equipment butif thereis something abnormal please turn tolocal UPS dealer forhelp avoiding unnecessary damage to the UPS Page 10 When the UPS hasthe f
7. ion of Long Back Up UPS s e x c seans sine 8 7 Maintenance lt 2 000225 ees seec ee cen cee eeenescceeseceeeseees 9 7 1 Preventative Maintenance esses see cts eee cee cee eee 9 7 2 Battery Maintenance rerreeeeeeeeeeeeeeeeeeeeeeeeees 10 7 3 Handling of abnormity Peer eee reer rere eee eee eee eee eee 10 8 Packing List Baise SiS Wie Wiaie a cE Sse Wa wa siewer secs encesecwewscee 11 SS__ ____ r 1 Remarks about Safety In order to keep safe in using the UPS please comply with the following Mi Please charge the battery atleast 12 hours before the UPSis in operation E A fter the battery is discharged orover three months without operar ion the battery should be charged immediately forat least 12 hours ensurmg the battery isfulland avoiding any unnecessary damage of thebattery MThe UPS is specially designed forcomputer only and it should notbe connected with any inductive orcapacitive load or the pure re sistance full load like electromotor daylight lamp laser printer etc MThe UPS is not suitable forbeing used in life support systems because it may have some problems and bring trouble tothe life support systems The responsibility will be users if they insist onusing the UPS in life supportsystems E It is normal that the temperature of the UPSsurface reaches up to50 C when it isin operation E When AC failsand the ON button on the front panel is pressed the UPS will output voltage ifthe
8. load for example PC pullout power gird 2 Put UPS onthe proper position following themanual 3 Connect load for examplePC to the UPS 4 Put the plugto the ACpower socket make sure GNDis connected well SUGGESTION OFFLINE UPS is the power supply for the computer monitor and hard disk CD etc It has the limited back time for the load so you d better not connect the printer or other equipments to it Page 7 AC Supply to PC 5 Connect toAC press the panelswitch turning on theUPS the green LEDand yellow LED light thenyou can turn onyour computer etc 6 Battery mode press the panel switch turning on the UPS the red LED lights then you canturn on your computeretc 7 Normally turning UPS press the panel switchturning on the UPS 8 Normally turning offUPS press the panel switchturning off the UPS Remark 1 Generally speaking don tturn off the UPS and keep batterycharging 2 Once AC fails UPS will turnto battery mode pleasesave important docme nts in time 6 2 Installation ofLong Back up UPS 1 Installation batteries connect the red cableto the anode andblack cable to the cathode pay attention to 24VDCups for 2 batteries connectin g in series 2 when the connection isright you d better connect withUPS before testing the voltage 24VDC Page 8 BLACK BLACK RED
9. ollowing problems pleasefollow the Steps belowand if the problem still can not besolved Please contact thelocal dealer Check whether the battery isn t charged charge enough Check whether the UPS is nd turned on correctly Battery fails to supply power UPS doesn t turn to AC the input Check whether the fuse is broken plug of the UPS has been plugged The fuse is placed on the UPS back panel into the AC socket and AC isnormal After disconnecting the AC plug put out and the on button has been the fuse and check whether the fuse is pressed but theAC indicating light broken if so please replace it with a new is not bright and the alarm beeps fuse Please turn on theUPS and charge the battery for at least10 hours when AC is normal and then turnon the UPS AC output is normal but the alarm beeps AC is over voltage or low voltage When AC fails the computer doesn t work 8 Packing List 1 UPS one piece 2 Users manual one copy 3 Fuse tube two pieces 4 Battery connector only for long backup model onepiece 5 Others according to customers requirements Page 11
10. pment or Class I loads 2 Working Principle 2 1 AC mode When UPSis innormal working mode AC goes throughthe filter and the harmful waves are filtered After that ACcharges the battery andmeanwhile passes UPSAVR and the filter and providepower for the equipment gt Fitter ava 2 7 a i Load output gt Le gt Les A Inverter oe _ Battery Page 2 2 2 AC Failure When AC fails the battery will supplypower to the inverterand then passes filterand provide power for theequipment ensuring the continuouspower supply ona gt Ler Joe Inverter _ crave Battery 2 3 Battery and Charging 1 When the UPS is connected toAC the charger will chargethe battery fully inabout 10 hours then thecharge light outautomatically 2 When thebattery is used up please charge thebattery immediately sothat to prolong the life of thebattery 3 Main Features 3 1 Unattended Operation E Please connect the UPSto AC andpress the ON button on the front panel the UPS is turned on andthe AC outputsstabilized voltage E When AC fails UPS will supply powerto the equipment immediately And when the battery is used up UPS will turn off automatically E When ACcomes back UPS willturn on automatically 3 2 Protection E Battery over dischargeprotection when the battery dischargesand the UPS is in inverter mode thebattery will check and monitor the working status ofthe battery when th
11. timeof self testing of the UPS and timingturn on off 3 4 Three Kindsof Alarm Function new model E When AC fails and the UPSsupplies power UPSwill alarmonce every 6seconds and the beep stopsabout 40 seconds later E When the batteryis nearly used up the UPS willalarm automatically andthe beep frequency isonce every 2 seconds E When the batteryis really used up the UPS will alarmfor a very longtime and turn off automatically 3 5 Lock Phase Function new model In AC mode the UPS system automatically tracks AC phase and ensures that the output wave fom oftheinverte is the same with AC voltage wave form in this way it reduces the peak pulse and surge voltage and minimizes the interference and damage to the equipment Page 4 3 6 No load turn off function automatically Optional when UPS is inverter mode it will automatically detect the load rating when the equipment load remains less than 5 UPS will be judged to be no load and automatically turn off after 1min to reducing unnecessary wear and tear to ensure that the UPS battery fully and longer battery life 3 7 The Function of the Self set Frequency CPU control When UPS is connected to AC the acquiescence frequency is 50 60Hz and UPS could be nspect the AC frequency automactally When AC shutdown the frequency is automatically set to 50Hz or 60Hz in accordance with AC 4 Specifications 500VA 600VA 700VA 800VA 1000VA 1500VA 525VA 650VA 750VA 850VA 1200VA

Download Pdf Manuals

image

Related Search

Related Contents

Weider WB330 User's Manual  F11 2nd 取扱説明書  取扱説明書  ADXL345 (Rev. E)  新規ご契約様へキャンペーンのお知らせです。  Server SGI™ 1400 Manuale di installazione rapida  Phonix IP3GBCRB mobile phone case  Fujitsu ETERNUS DX DX80  User`s Manual - CableWholesale  Untitled  

Copyright © All rights reserved.
Failed to retrieve file