1. Is the air filter clogged Clean the air filter as instructed under cleaning section Is the air intake or discharge duct Remove the obstructions obstructed The ambient air humidity is lower than 50 RH E2 error may be on LCD Below 50 RH the dehumidifier becomes inefficient It is recommended to switch off the dehumidifier Operation is noisy Is the unit tilted or unsteady Move the unit to a stable sturdy location Is the air filter clogged Clean the air filter as instructed under cleaning section The air filter is soiled Wash the air filter The unit may be wet Allow more time to dry 15 Compressor overload sensor maybe Contact the service centre defective Compressor does not start Running capacitor Contact the service centre maybe defective The dehumidifier will switch on the fan automatically after defrost ends If this fails contact the service centre The dehumidifier is in The fan does not spin defrost cycle Fan not running Contact the service centre i F f Defective PCB Contact the service centre Unit continuously in defrost and you can see an ice block on the evaporator P The room temperature is to low E1 may be on LCD Defective relay valve Contact the service centre Defective temperature Contact the service centre sensor Unit does not defrost Defective control Contact the service centre assembly Note when
2. hence the drain should be lower than the dehumidifier water outlet Be sure to run the water pipe downward and let the water to flow out smoothly Do not kink or bend the pipe NOTE The permanent drain can be used in conjunction with water pump e g when draining a cellar to lift the water upwards Certain models may feature and embedded pump 12 Care and Maintenance Always switch off the unit and unplug from the mains before cleaning or performing any maintenance When it is not in use for long periods it is advised to remove the plug from the plug socket Do not use chemical solvents such as benzene alcohol or gasoline as they may cause irreversible damage to the unit 13 Filter Cleaning Air inlet and air outlet may gather dust easily please clean it often with a soft damp cloth If the filter is covered by dust the airflow and the performance of the unit will be affected it may even cause machine damage We recommend that you regularly clean the filter Let the unit dry before reuse 1 Take the air inlet grill out first than remove the filter from the unit 2 Clean the filter with a vacuum cleaner or soft brush 3 Replace the filter in position Grille and Case Cleaning Use water and a mild detergent Do not use bleach or abrasives Do not splash water directly onto the main unit Doing so may cause an electrical shock and can lead to the insulation to deteriorate or cause the unit to rust The air intake and outl
3. N AMCOR ACD9OL 90 day Commercial Dehumidifier with digital Humidistat USER MANUAL TE Thank you for choosing Amcor Please read this user manual before using this innovative Commercial Dehumidifier and keep it safe for future reference Visit our page www amcoruk com for our entire range of Air Treatment products 0 Contents Safety Instructions saessesssessesessssssessseesesrssesseens Parts 0 AN Control Panel aanasesesssressssrresesesreseseeenrersse Quick reference guide essssssssssssssrssssrersrsseerrses Operation galmadi aair Positioning assesessssesssresressreseeeseeeesseseene Water Drainage assssesseessressreeressesseresrressesse Care and Maintenance eessessesssssssesesssesersrereresene Troubleshooting aseessesesessssrsseensesrssrsseeseresene Technical Data akenei ani SAFETY INSTRUCTIONS e Carefully read the instructions before operating the unit If used on commercial premises the site manager should ensure that the operator has access to the user manual and understands the operation of the unit e This appliance is for indoor use only and intended for use in a commercial or domestic environment only Any other use is not recommended by the manufacturer and may cause fire electrical shocks or other injury to operator or property e Rating This unit must be only connected to a 220 240 V 50 Hz earthed outlet Always operate the unit with the grounding plug supplied A ground
4. creases the risks of operating it eThis dehumidifier must not be used in spaces where there is a high concentration of gases solvent or other volatile organic compounds in very dusty environment in any commercial or industrial environment where air composition is flammable e Avoid touching any moving parts of the appliance Never insert fingers pencils or any other objects though the guard e This appliance is not intended for use by operators including children with reduced physical sensory or mental capabilities It is also not intended for use by those with a lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety 2 Do not operate the dehumidifier in pooled or standing water as this may create a risk of injury from electrical shock If the case or the inside of the unit become wet dry the unit before restarting it If fails to operate discontinue use and call the service centre e Do not clean the unit by spraying it or immersing it in water e Any service other than regular cleaning or filter replacement should be performed by an authorized service representative Failure to comply could result in a voided warranty e Do not use the appliance for any other purposes than its intended use e Do not tilt the unit while in use The unit is design to work only in vertical position Always operate the unit on a stable level surfac
5. e e g solid floor so that the dehumidifier cannot fall and cause accident eThis dehumidifier must always be stored upright otherwise irreparable damage may be caused to its compressor e Rest for minimum 8 hours after been transported in horizontal position Avoid restarting the dehumidifier unit unless 5 minutes have passed since being turned off e Never use the mains plug as a switch to start and turn off the dehumidifier Use the provided ON OFF switch located on the control panel e Always place the unit on a dry and stable surface e The appliance should not be installed in laundry or wet rooms where the humidity is higher than 85 RH Operate this unit in an ambient temperature between 5 C and 40 C e Avoid any water ingress into dehumidifier Make sure no dust or wet building materials are entering the unit e Do not place the unit next to heat sources e g electric or gas fires radiators boilers etc Energy Saving and Unit Safety Protection Tips e Do not cover or restrict the airflow from the outlet or inlet grills e For maximum performance the minimum distance from a wall or objects should be 50 cm e Keep the filters or grills of the unit clean Under normal conditions filters or grills should only need cleaning once every two weeks approximately Do not use the unit without the air filter as this will allow dirt to gather inside the dehumidifier and could invalidate the warranty A dirty filter will restrict the air f
6. et grilles get soiled easily so use a vacuum attachment or soft brush to clean Out of season storage 1 Turn off the unit and wait for the drying cycle to finish before unplugging the power cord 2 Clean and dry the water tank 3 Clean the filter air inlet air outlet and unit body 4 Coil the power cord in the holder 5 Cover the unit to prevent it from gathering dust 6 Store the dehumidifier in a cool and dry place ra a 2 Qa Q amp Q Q Q a SR Q Q ss QB F Power Cord Maintenance and Replacement If the power cord is damaged it could cause a short circuit or become a fire risk Please avoid pulling the cord twisting or pressing it and keep it away from pets If the power cord is damaged power the unit off and unplug if immediately Contact an electrician for repairs do not attempt to repair the unit yourself 14 Troubleshooting Issues Possible Cause Solution The unit does not operate Has the power cord been disconnected Plug the power cord into the socket Plug in the unit also check power at outlet Check if the used voltage is lower or Check and make sure rated voltage only to higher than the rated restart the unit voltage Is the room temperature above The temperature protection sensor is 40 C or below 5 C E1 error maybe on LCD activated and the unit cannot be started The dehumidifying function does not work or no air is discharged
7. f you have a serious problem in one area you can begin by positioning the dehumidifier there and moving it to a more central location at a 10 later date Please note the unit should not be placed directly against a radiator or other heat source When positioning your AMCOR dehumidifier ensure that it is placed securely on a level surface clear of any obstacle that may limit the air movement This dehumidifier is designed only for indoor residential office and commercial industrial applications Place the dehumidifier on a flat dry surface The dehumidifier must be operated in an enclosed area to be most effective Close all doors windows to create the best operating environment Do not use outdoors Water Drainage This unit was designed to extract a very large amount of water while being compact and portable 11 Continuous draining This dehumidifier has a continuous drain hole that can be connected with a plastic pipe The water in the body will drain through the drain hole Water can be automatically plumbed in or drained into sink a larger external tank or bucket or through the wall into an outside drain by attaching a pipe to the unit A standard pipe is supplied with the unit Insert the pipe into the drain outlet at the back of the unit Make sure the connection between pipe and the drain outlet is tight and do not leak Then direct the pipe to a suitable drainage point This unit uses gravity fall to dispose water
8. ing plug is a safety feature that helps reduce the risk of shock or fire e f you are in any doubt about the suitability of your electrical supply have it checked and if necessary modified by a qualified electrician e This dehumidifier has been tested and is safe to use However as with any electrical appliance use it with care This unit is a commercial industrial dehumidifier and was not designed with children in mind Do not allow children to play with or around this commercial dehumidifier this could result in injury Make sure the unit is not accessible to children either in use or not e Installation must be in accordance with regulations of the country where the unit is used e Disconnect the power plug from socket before dismantling assembling or cleaning e Never connect the unit to an electrical outlet using an extension cord If a power outlet is not available one should be installed by a qualified electrician Using extensions will lead to reduction of voltage supplied to the unit and overheating of the electrical cable at can only be done to customer risk e Never operate this appliance if the cord power adapter or plug is damaged Ensure the power cord is not stretched or exposed to sharp object edges e A damaged power supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard e Avoid mishandling the dehumidifier Dropping throwing the unit can cause damage to its internals and in
9. ll show ambient humidity 3 After being turned off the machine will remember the last settings for the next power cycle 4 When unplugging from the wall socket use one hand to hold the plug and the other hand against socket to avoid power cord damage Warning Using poor quality sockets extensions or overloading the circuits may cause damage to the machine or may start a fire 5 When switching OFF the machine do not simply unplug the unit from the socket ensure you turn off the machine properly before unplugging After dehumidifiers is OFF the fan will keep running for a couple of minutes and heat will be produced to dry the dehumidifier Humidity control When room humidity is higher than set humidity by 3 Fan and compressor will start dehumidifying When room humidity is lower than the user setting by 3 fan and compressor will stop Humidity display settings range 20 95 Timer control Stopping timer On power on mode adjust the stopping timer using key to select the number of hours after the unit will stop Start timer On power on mode adjust the start timer using key to select the number of hours after the unit will start Then turn off the unit The dehumidifier will restart after the set time Auto restart For models with memory function the dehumidifier will restart in the same operation mode as before power off state Protection and Diagnosis After working for 30 minutes if the compressor coil sens
10. low into the machine which will increase the resistance on the fan and could result in damage and might invalidate the warranty Since the filters remove airborne particles more frequent cleaning maybe necessary depending on the air quality Vacuum and wash the mesh filters with hot soapy water and dry them before placing them back in the unit Do not allow grease oil or any contaminants to be absorbed into dehumidifier 3 Features Your Amcor dehumidifier is a top of the range commercial dehumidifier with features not found in other units Large 90 litres per day max extraction Metal body ideal for hire or commercial operation Portable on large castors efficient easy to use LCD screen with Humidity display Intelligent CPU controlled humidistat with exact settings and power saving logic Auto mode for easy set and forget operation Touch control panel with led indicator Timer on off settings Permanent drainage with uplift pump included ON eo rin ES O OND Installation Remove any water from the water tank before starting the unit In order to save energy do not open windows or doors while the unit is running Place the unit on a hard flat surface On first use run the unit continuously for 24 hrs To reduce noise levels Place a piece of carpet or a rubber mat under the unit to reduce any vibrations while the unit is running Amcor commercial dehumidifiers use compressor technology to extract water from the environ
11. ment The Amcor range of commercial dehumidifiers are ideal on ambient temperatures ranging between 5 30 C We recommend using the units at above 10 15 C Amcor commercial dehumidifiers are light and easy to move around on large wheels and caring handle They are also intelligent dehumidifiers which will extract unwanted humidity while saving money due to their humidistat and advanced power saving logic They features an intelligent humidistat with exact settings and auto mode insuring your room is not dried too much and power is not wasted PARTS Poa 3 Ss a R D eR Name N Name N Name No Name o o Right side panel 5 Outlet grill 9 Small castors 13 Power plug with stopper Top panel 6 Inlet grill 10 Rubber wheels 14 Cable holder Control panel 7 Side handle 11 Drainage pipe 15 Power cord Left side panel 8 Front panel 12 Rear handle 16 Air grill Optional accessories 1 Carbon filter Optional 2 PU filter Optional CONTROL PANEL HUMIDITY DEHUMIDIFIER S a Re i OOm Bp TIME OFF nasal Mimil TIME ON OUTLET MINUS a T j E T industrial Dehumidifier Operating Keys and Quick Guide Power On Off Key beeps twice Turns the unit On Off Timer Selection Key Selects the stopping timer or continuous operation Dehumidification Level Controls Keys Set the target humidity level set desired humidity with an incre
12. ment of 5 RH or sets to continuous dehumidification Keep the button pressed for 2 seconds to advance quicker If you press first the Timer Selection Key first than humidistat can be setup in conjunction with the timer Mode Key AUTO shows AU on LCD AUTO dehumidifying a If ambient temperature lt 5 C compressor will not start compressor protection b If ambient temperature between 5 C 20 C unit will work with RH60 preset c If ambient temperature between 20 C 27 C unit will work with RH55 preset d If ambient temperature gt 27 C unit will work with RH50 preset 6 Continuous dehumidifying LCD shows CO unit work without humidity control Standard dehumidifying unit work as standard following the humidity setting Auto defrosting function in low ambient temperature When the unit is running in a room with temperature between 5 C and 12 C it will be stop to defrost for every 30 minutes When the unit is running in a room temp between 12 C and 20 C it will be stop to defrost for every 45 minutes Operational Advice 1 Take out the unit from the box if required keep the packaging material to repackage the unit for storage Connect the pipe to the drainage port tightly Note make sure the correct connection is used with the rubber sealed pipe avoiding leakage problem 2 Plug to power press ON OFF key to turn on the machine press ON OFF key again to turn off the dehumidifier The LCD display wi
13. or reach 1 C unit will stop to defrost This is normal operation If the detected temperature exceed the operation range unit will indicate E1 error code which is temperature sensor fault In such a mode unit will be with dehumidifying 30 minutes and defrosting for 15 minutes This is normal operation and will recover as soon the temperature will change If the detected humidity exceed the operation range the dehumidifier will indicate E2 humidity sensor error Unit will work trying to dehumidify continuously After the temperature and humidity fails back within main operating range unit will start operating again Positioning the dehumidifier wer Badly positioned dehumidifiers will have little effect in effectively drying the place In positioning the dehumidifier please ensure circulation of air in not restricted around the unit Please observe figure bellow in installing the unit Your AMCOR dehumidifier will begin to protect your space from the harmful effects of excessive moisture as soon as it is turned on Excess moisture travels throughout your place in the same way that cooking smells spread around the house For this reason the dehumidifier should be positioned in a central and clear location so that it can draw this moist air towards it from all over the place A warmer spot is an excellent position for your dehumidifier If possible leave interior doors ajar to allow air circulation Alternatively i
14. the fault cannot be solved by the solutions above please contact service centre for help do not attempt repairs Assure that the device is only set up in rooms with temperatures above 5 C 16 Technical Data Model ACD90L Rated dehumidifying capacity 90L Day Rated voltage 220V 50Hz Rated current 5 8A Rated power consumption 1250W Max power consumption 1420KW Max current 6 59 A Max condensing pressure 3 6 MPa Max evaporating pressure 0 72MPa Tested condition 30 C 80RH Refrigerant R410a 800g Weight 53kg Gas R410A Global Warming Potential GWP 1890 The unit cannot be operated when room ambient temperature is lower 5 C Rated capacity was tested under 30 C RH80 test condition Disposal Do not dispose this product as unsorted waste Collection of such waste must be handled separately as special treatment is necessary Recycling facilities are now available for all customers at which you can deposit your old electrical products Customers will be able to take any old electrical equipment to participating sites run by their local councils Please remember that this equipment will be further handled during the recycling process so please be considerate when depositing your equipment Please contact the local council for details of your local household waste recycling centres A All information provided is for reference only Products specifications may change due
15. to continuous product development ACD90LI_K29092014_V2 17 AMCOR UK SUPPORT Please for your own convenience make these simple checks before calling the service line Has the unit been standing upright for at least 2 hrs Is the unit plugged into the mains Is the fuse OK Switch the unit on and wait three minutes to see if the issue is resolved Check whether the water tank is full If the unit still fails to operate call 0871 620 1057 or fill the online form Office hours 9AM SPM Monday to Friday www amcoruk com Unit 2 The Nursery Berristow Lane South Normanton Derbyshire DE55 2FX 18