1. OPERATION OF THE APPLIANCE The purpose of the Intergas Rapid wall mounted gas fired boiler is to heat water and to supply it to the central heating CH system and the domestic hot water DHW taps The heat exchanger comprises of two separate systems for central heating and DHW The appliance is fitted with a modulating control This means that the power is adjusted in line with the required heat The boiler controller responds to each call for heat from the heating or the DHW system by igniting the burner and monitoring the flame 1 1 Operation of the central heating The call for heat arises as a result of the room temperature being lower than the temperature set on the room thermostat If at that time the appliance does not have a call for DHW the appliance comes on in central heating mode The central heating temperature control modulates on the basis of the set central heating supply temperature This means that when the desired central heating supply temperature is approached the appliance adjusts the power The pump for the central heating has a post purge period of 1 minute The post purge period may be changed if desired The pump runs automatically for 10 seconds once every 24 hours to prevent blocking 1 2 Operation of domestic hot water supply The DHW system is started automatically as soon as more than 2 litres of water per minute are drawn During delivery of hot tap water no heat is supplied by the appliance to the central heating syste
2. radiators and or an air bleed in the piping e Check that after bleeding the system the water pressure in the installation is still between 1 and 2 bar if not repeat the procedure If the system has to be filled more frequently than a few times a year notify your installer since this means that there is probably a leak 5 2 Domestic hot water supply Pressurise the DHW part of the appliance by opening the main tap and or the inlet assembly Remove air from the appliance and the pipe work by opening a hot water tap Leave the tap open until all the air has disappeared from the appliance and the pipe work Close the hot water tap Check the connections for leakage 5 3 Frost protection To prevent freezing of the condensate drain the appliance should be installed in a frost free room The appliance is equipped with frost protection which as long as mains current is present switches on the CH pump and if necessary the burner when the heat exchanger temperature falls too far NB If an internal or external frost thermostat has been installed in the system and connected to the appliance it is not active when the appliance has been switched off at the operating panel on service display 6 MAINTENANCE The appliance can be cleaned with a damp cloth Do not use aggressive or abrasive cleaning agents or solvents The appliance and the installation should be checked and where necessary cleaned annually by a registered installer The s
3. the room e The gas tap must be open e Switch the appliance on with the on off key in the display The LED lights up and the service display goes out The appliance may now heat up for purposes of the DHW system until the heat exchanger reaches the set temperature e Set the clock and the switch moments If the boiler is in a time block that CH is not active the boiler must be set in c on see 2 2 e Set the room thermostat higher than the actual room temperature The appliance will fire for purposes of the CH system 4 FAULTS If the following simple appliance faults occur they can be resolved as follows In the case of repeated occurrence or other faults always notify your installer 1 The CH system does not heat up or does not become sufficiently warm e Increase the temperature setting at the room thermostat e Open the radiator valves e increase the CH water temperature setting using the and the and key on the operating panel see 2 e Bleed the appliance and installation and check the CH water pressure 2 The domestic hot water supply does not become hot or hot enough e Open the domestic hot water tap further e Set the domestic hot water temperature higher using the and the and key on the operating panel see 2 3 The fault LED above the reset 1fr key is flashing The following codes are indicated on the display 4 Irne appliance becomes too hot there is insufficient flow Open the radiator valv
4. MM INTERGAS gt Rapid 25 Rapid 32 Operating Instructions Installation of the appliance may only be carried out by an installer competent person Please ask your installer to instruct you on how to fill and bleed the appliance and the installation and on their operation Strictly abide by all the instructions and warnings Always use the appliance in accordance with the Operating Instructions It is forbidden to interfere with a sealed component CONTENTS 1 Operation of the appliance 2 1 1 Operation of the central heating cccesssssesssssssssssseesssssesssseseesaseserees 2 1 2 Operation of domestic hot water supply cccecsescseecseeesseseetecesseeeeseeey 2 2 Operation and display read out 2 2 1 Operating mode on the service display ceccsessesesseeeessseeecssseessseeeees 3 2 2 Changing the settings of the various FUNCTIONS cccseeesesseeestseeeseteeeees 3 3 Start up 3 4 Faults 3 5 Filling and bleeding appliance and installation 4 5 14 Central heating system snnnnsnenneesennersrsresrsnsrrsrsrnrrsrsnnnrersrenrnrsrnsrsrsrenns 4 5 2 Domestic hot water SUPPLY ccccccseessecseescsessscsssesessecsseessessseeseesersateess 4 39 Frost protection ee a ee eee 4 6 Maintenance 4 2015 Intergas Heating Ltd Subject to change THE MARK OF QUALITY FOR THE INSTALLATION COMMISSIONING AND SERVICING OF DOMESTIC HEATING AND HOT WATER SYSTEMS Intergas Heating Ltd is a licensed
5. ame applies to the flue pipe and air supply pipe If you smell gas or are worried about gas safety please call the National Gas Emergency Service at 0800 111 999 For more details visit the website of the National Grid www nationalgrid com uk Gas Safety Emergency Always use a Gas Safe registered engineer to fit fix or service your gas appliance To find or check an engineer call Gas Safe Register s free helpline on 0800 408 5500 or visit www GasSafeRegister co uk Intergas boilers are manufactured in a Kiwa ISO 9001 certified production faccility kiwa certified t Intergas Heating Ltd fee 88877700 docx Intergas Heating Ltd Tel 01527 888000 Building 94 Bay 1 Vantage Point Fax 01384 279480 The Pensnett Estate info intergasheating co uk Kingswinford www intergasheating co uk West Midlands DY6 7FS
6. ay appears P for a short period e Pressing the button for less than 1 second the following additional functions can be activated 1 t on temporary on the boiler will respond on every CH demand from the room thermostat until the next switch moment 2 c on continuous on the boiler will respond on every CH demand from the room thermostat without any time limit 3 OFF the boiler will not respond on any CH demand from the room thermostat Ii The maximum CH supply temperature Can be set between 30 C and 90 C standard setting 80 C Low setting for moderately cold weather high setting for colder weather DHW temperature Can be set between 40 C and 65 C standard setting 55 C All other alterations of settings of the boiler may only be carried out by your installer 3 START UP Once the appliance has been connected to water gas and electricity supplies and checked by an authorised installer the appliance can be started Please check the following points e The central heating system and domestic hot water system must be well filled and bled e The appliance must be switched off Horizontal dash on service display other LEDs off e The water pressure in the central heating system must be between 1 and 2 bar Shown on the temperature display Never switch the appliance on if the appliance the CH system and the DHW system have not been completely filled and bled e The room thermostat must be set below the temperature in
7. eco G Service button 8 DHW comfort function on continuous H Reset button 9 Operating code 10 Flashes to indicate fault 2 1 Operating mode on the service display Off appliance frost protection active Ventilate Ignite CH pump post run CH mode Desired temperature reached DHW mode Self test E Heat up appliance Note When the red LED above the reset key flashes a fault has occurred A fault code will then appear on the temperature clock display 2 2 Changing the settings of the various functions Keeping the key pressed for 2 seconds takes you to the user settings menu LED at iif and the amp display starts to flash Then each time you press the key a different function LED will start to flash The value of the function can be set using the and keys The value set is displayed on the 8 display e The reset wr key closes the settings menu and stores the changes e fno key is pressed for 30 seconds the settings menu is automatically closed and the changes are stored e The on off key closes the settings menu without storing the changes e The button restores the default setting for the switch moments hold for 5 seconds e By pressing the or keys the clock can be set and the switch moments can be defined e By pressing the button 2 time blocks can be programmed in which the CH is on switch moments 1 to 4 e By pressing the vr button the new times will be stored in the boiler controller In the displ
8. es bleed the appliance and installation and check the CH water pressure If necessary top up see 5 ly The burner does not light Consult your installer After rectifying the fault press the reset button and the appliance will start up again For the meaning of the other operating and fault codes please refer to the installation instructions 5 FILLING AND BLEEDING THE APPLIANCE AND INSTALLATION NB Switch the appliance off with the key Do not switch the appliance on again until after filling and bleeding 5 1 Central heating system In order to guarantee a successful operation of the CH installation the water pressure in the system in case of a cold system should be between 1 and 2 bar If the pressure is too low the system should be topped up Proceed as follows e Connect the filling hose to the drinking water tap and fill the hose with water until there is no longer any air in the hose Filling is only allowed via an approved filing loop that has check valves fitted Connect the filling hose to the filling drain tap at the bottom of the appliance Open the drinking water tap and then the filling drain tap Fill the appliance and the system until a cold water pressure between 1 and 2 bar is reached Close the filling drain tap and then the drinking water tap Bleed the system and the appliance The appliance bleeding point is located at the top left on the appliance The system can be bled via the bleed taps on the
9. m For purposes of fast delivery of hot tap water a DHW comfort function has been installed in the controller This function maintains the temperature of the heat exchanger The DHW comfort function has the following settings On LED on The appliance s DHW comfort function is turned on continuously In this mode the heat exchanger will be kept on temperature to assure instant delivery of hot water Eco X LED on The appliance s DHW comfort function is an intelligent system The appliance will adapt to the pattern of use of hot tap water As a result the temperature of the heat exchanger will only be maintained in periods during which domestic hot water was drawn on previous days Off Both LEDs off The temperature of the heat exchanger is not maintained as a result of which the delivery of hot tap water takes a little time If there is no need for rapid delivery of hot tap water the DHW comfort function can be switched off 2 OPERATION AND DISPLAY READ OUT 0 C lease LP PPP ff a Read out Operation 1 On off A On Off button 2 CH operation or setting maximum CH temperature B DHW CH button for setting desired temperature 3 DHW operation or setting DHW temperature C button 4 Desired temperature of CH or DHW in C CH water pressure bar Fault code Time D button 5 Clock on CH enabled E Clock function setting 6 Clock off CH disabled F DHW comfort function off eco on 7 DHW comfort function
10. member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety efficiency and performance Benchmark is managed and promoted by the Heating and Hotwater Industry Council For more information visit www centralheating co uk Please ensure that the installer has fully completed the Benchmark Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that you have received a full and clear explanation of its operation The installer is legally required to complete a commissioning checklist as a means of complying with the appropriate Building Regulations England and Wales All Installations must be notified to Local Aerea Building Control either directly or through a Competent Persons Scheme A Building Regulations Compliance Certificate will then be issued to the customer who should on receipt write the Notification Number on the Benchmark Checklist This product should be serviced regularly to optimise its safety efficiency and performance The service engineer should complete the relevant Service Record on the Benchmark Checklist after each service The Benchmark cheklist may be required in the event of any warrranty work and as supporting documentation relating to home improvements in the optional documents section of the Home Information Pack 1