1. manganese or iron scaling from excessive hardness turbidity greater than 1 0 NTU Silt Density Index SDI greater than 5 0 SDI or excessive membrane hydrolysis due to chlorine levels in excess of 1 0 mg L ppm In addition damage to the unit due to fire accident negligence act of God or events beyond the control of the Manufacturer are not covered by this warranty Incidental and Consequential Damages Limitation The Manufacturer will not be responsible for any incidental or consequential damages as a result of the failure of this unit to comply with express or implied warranties or any defect in the unit including but not limited to lost time inconvenience damage to personal property loss of revenue commercial losses postage travel telephone expenditures or other losses of this nature In case some states do not allow the exclusion or limitation of incidental or consequential damages you may choose to return the system If you choose to keep it you Insist this exclusion STILL apply to you Owner s Warranty Responsibilities As a condition of this Limited Warranty the owner must ensure periodic maintenance of the system is performed as described in the literature enclosed with the system Neglect improper maintenance abuse modification or alteration of the unit will invalidate this Warranty Should your unit develop a defect or otherwise fail to perform in accordance with this warranty you should contact the retailer from whom the
2. product was originally purchased Implied Warranties The implied at law warranties of merchantability and fitness for a particular purpose shall terminate on the date one year after the date of purchase Note in case some states do not allow limitations on how long an implied warranty lasts you may choose to return the system If you choose to keep it you insist the above limitations STILL apply to you WO COND UI B amp B UW L www 123filter com 678 261 7611 oe sales ispringfilter com Page 2 Introduction Congratulations on your purchase of the iSpring RO system Featuring a multiple stage filtration process the Reverse Osmosis technology incorporates polypropylene sediment PP granular active carbon GAC carbon block CTO and optional Calcite mineral alkaline filter and Ultra Violet filter to produce crisp tasting bottled quality drinking water right at your home When properly maintained this system will provide you with years of trouble free service Please keep this manual for future reference The next sections contain important information on the proper care and maintenance of your system Please take a few minutes to read through this information The cartridges in RO system must be replaced on a regular basis to maintain efficiency and to ensure high water quality These cartridges work together and must be replaced every 6 12 months Any significant change in performance of the system should be investigated promptly
3. tubing to this elbow fitting 0 and the other end to the Feed Water Adapter AFW 6 on your cold water line 6 2 Insert the tubing into the flow restrictor 5 which lays beside the membrane housing and further connects to the drain saddle 7 to flush out the waste water 6 3 On the right side of the Post Carbon Filter labeled T33 or FT15 insert the tubing into the T fitting 1 and the other end to 9 the ball valve of the Tank 6 4 Model without UV AK DI Insert the tubing links to RO faucet into the elbow fitting at left end of T33 Filter 2 Model with UV AK DI Insert the 13300 D tubing links to RO faucet into the elbow fitting at right end of UV AK DI filter 4 whichever is the last stage 6 5 Install the other end of tubing onto 8 RO faucet 6 6 You may organize the tubings but make sure to leave enough length so the filter system can be moved around the cabinet easily when replacing filters L iw www 123filter com 678 261 7611 ited sales ispringfilter com Page 9 6 7 You may hang the system using two 10 x 1 1 4 Brass Phillips Flat Wood Screws This will make replacing filter cartridges easier mecca Step 7 Install Drain Saddle 7 1 Tea 7 3 7 4 Choose a spot on drain pipe that is convenient for installing drain saddle and tubing Horizontal pipe is recommended to limit sound of drainage water running out from system Drill a 1 4 hole on drain pipe 2 Drain p
4. here Cut the 1 4 tubing between RO system and RO faucet insert the end to RO faucet here 2 Insert the end from RO system here A www 123filter com 678 261 7611 i sales ispringfilter com Page 11
5. screw and tighten the nut with your hand Use wrench for final 1 4 turns CWSvV r a www 123filter com 678 261 7611 preted 4 sales ispringfilter com Page 8 Step 4 Install RO Drinking Faucet 4 1 If your kitchen sink does not have a spare 1 2 hole you will need to drill one Refer to page 6 The Tips for Drilling a Hole on Sink or Counter top Wipe clean and dry the area 4 2 Remove blue protection film from front plate slip it on faucet thread and slip on black rubber washer Front plate that has 3 circles Insert the faucet thread portion into the hole Optional plumber glue or sealer could beused Front washer f g 4 3 Under the sink tighten back rubber washer small lock washer and nut a aT d 4 4 Slip the compression fitting nut and collar on BLUE Tube inset tubing push the myst into the tubing insert into a faucet end and tighten up the nut Pull the tubing to check if it is secure lock washer Collar Step 5 Install Tank Shut off Valve TSV pLUES 5 1 Wrap six turns of Teflon tape clockwise onto the valve thread at the top of the tank 5 2 Screw Tank Shut off Valve on and tighten up by hand Do not over tighten 5 3 Install the YELLOW tubing onto Quick Fitting of TSV Nute Step 6 Tubing Hook up Model specific steps ao 6 1 When facing the iSpring logo on the front plate the vertical Ist stage clear housing is located on the right hand side Connect the
6. to avoid secondary damage or deterioration to other parts of the system CAUTION Improperly installed systems could result in water damage due to leaks or flooding Proper installation of this system requires familiarity with standard sink plumbing and proper use of common hand and power tools If you are not familiar with standard sink plumbing and proper use of common hand and power tools or have any difficulty with the installation of this system consult a licensed professional such as a contractor or plumber NOTE This system has been designed for installation by licensed professionals such as a contractor or plumber Filter Catridge Replacement Schedule m pl r ae ome dire Fihi ira Bon To Carbon Filler i F Stage 1 Stage 2 Stage 3 Stage 4 Stage 5 Stage 6 Stage 7 Sediment GAC CTO RO Membrane Inline Carbon Alkaline UV Lamp FP15 FG15 FC15 MC1 FT15 FA15 UVB11 6 months 6 months 6 months 2 9 years 12 months 6 months 12 months Note stage 6 or 7 only exists in certain models A www 123filter com 678 261 7611 preted 4 sales ispringfilter com Page 3 System Operating Conditions Feed water pressure 45 80psi or 30 80psi for systems with built in booster pump Feed water temperature 40 100 degree F 4 37 degree C RO system is not designed for hot water source Feed water TDS 750 ppm maximum If feed water has severe iron rust problem an iron filter is required prior t
7. 8 261 7611 oe sales ispringfilter com Page 1 Limited Warranty This Limited Warranty extends to the original purchaser of the system only This warranty covers all Manufacturer supplied items only that prove to be defective in material workmanship or factory preparation This warranty covers parts only all labor is excluded from this warranty including but not limited to services related to the removal replacement installation adjustment maintenance and or repair of the unit or its components items excludes all non Manufacturer labor required for any servicing of the unit including but not limited to servicing related to installation adjustment maintenance and repair of the unit This warranty applies only for the first full calendar year from date of purchase The following items are excluded from this warranty membranes filters O rings and all other parts or components that require regular replacement as a result of ordinary usage Disclaimers This Limited Warranty applies only if the system is installed used and maintained in compliance with all instructions and requirements enclosed with the system This warranty will be void for failure to observe the following conditions 1 The system is to be used with potable water supply only 2 Feed water pressure to the unit is no less than 45 PSI 30 PSI for systems with built in booster pump and no greater than 80 PSI The system is to be used on water supplies with chlorine conc
8. SSYS O ring seated in the groove lst stage transparent housing 2nd stage housing 3rd stage housing Ist stage sediment cartridge 2nd stage GAC cartridge 3rd stage CTO cartridge 4th stage RO membrane housing cap _ 4 stage RO membrane 5th stage Post carbon T33 10 Optional 6th stage Alkaline mineral filter 11 5 stage outlet to RO Faucet tubing or optional 6th stage 12 Tubing in four colors O CON DU BWN FE Recommended tools list 13 14 Optional ice maker kit 15 Housing wrench for stage 1 3 16 Housing wrench for RO membrane 17 Tank fitting YELLOW tubing 18 Tank air inlet 19 Cold water adapter male end 20 Cold water adapter female end 21 Drain saddle sticky pad hidden 22 RO faucet installation kit 9 pieces 23 RO faucet MHS tubing from final stage 24 Cold water inlet NB tubing i ng in 25 RO water outlet to TANK SENON tubing 26 Spare 3 O rings 2 elbow quick fittings and lock clips Variable speed drill and drill bit 1 4 for the drain line 1 2 optional for drilling hole on counter Open end wrench in 5 8 and 9 16 or adjustable wrench Pliers Phillips screwdriver Utility knife Scissors Teflon tape Bath towel bucket ae www 123filter com 678 261 7611 preted 4 sales ispringfilter com Page 6 Installation Tips Lock sleeve How to use Quick Fitting a l 1 Viewed from the open end a quick fitting starts wi
9. e slipped on housing body for stronger hand hold 2 3 Follow the flow direction sign on the membrane and firmly insert membrane into housing with the smaller end thathas gt SF RIN two black O rings first until the other end is even with housing opening 2 4 Screw cap and insert white tubing back on Hang tight and tighten up for about 1 4 1 2 turn using small plastic housing wrench but do not over tighten Step 3 Install 3 8 Feed Water Adapter AFW 3 1 Turn off the Cold Water Line at your sink via the Cold Water Supply Valve CWSV Turn on kitchen faucet to release any pressure and make sure water has stopped before proceeding to the next step 3 2 Get a towel or bucket to catch any water drips Disconnect Kitchen Faucet Connector KFC from CWSV Wrap CWSV with 2 3 turns of Teflon tape and screw on the AFW at the female end with O ring Tighten using wrench or pliers Note the AFW in iSpring tool kit is 3 8 which fits most common flex pipe in U S However if yours happen to be in a different size this is usually a size of 9 16 please get an adapter from Home Depot 3 3 Reinstall KFC on the male end of AFW Turn the handle of AFW to cross OFF position Turn on CWSV slowly check and fix any leaks 3 4 note If the fitting end of the AFW is not a quick fitting but a compression fitting then unscrew the nut and slip it onto 1 4 tubing Insert the tubing into the AFW the T push in firmly and then
10. entrations of 1 0 mg L ppm or less Feed water temperature to the unit must be no less than 40 F and no more than 100 F Total dissolved solids TDS in feed water must be less than 750 mg L ppm Feed water must have a pH between 4 and 8 Turbidity must be less than 1 0 NTU SDI must be less than 5 Feed water must be completely free of iron manganese or hydrogen sulfide Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system The Manufacturer does not know the characteristics of your water supply The quality of water supplies may vary seasonably or over a period of time Your water usage may vary as well Water characteristics can also change if the drinking water appliance is moved to a new location The Manufacturer assumes no liability for the determination of the proper equipment necessary to meet your requirements and we do not authorize others to assume such obligation on our behalf This Limited Warranty does not cover any Manufacturer supplied items that are defective as a result of the use of improper parts equipment or materials This warranty does not cover alterations or modifications of the unit or failure of a unit caused by such alterations and modifications This Limited Warranty does not cover malfunctions of the unit due to tampering misuse alteration lack of regular maintenance misapplication fouling due to hydrogen sulfide
11. iSpring Reverse Osmosis Water Filter Systems USER S MANUAL Under sink 5 stage 6 stage 7 stage RO systems Version 2014 3 Spring Water Systems I LLC since ae Copyright 2005 2014 ISPRING WATER SYSTEMS LLC All rights reserved Warranty Registration We provide 30 day money back guarantee 1 year Manufacture Warranty and lifetime tech support to all products However we do not have the order information from the vendors other than 123Filter com The easiest way to activate the warranty is to forward your order confirmation email to sales 123filter com along with your comment or if you prefer please fill out and mail the form below Please remember we love to help customers If you have any question or concern about our products please don t hesitate to call or email us We will do all we can to make your purchase a 5 star experience lf you are happy with our product and service please show your support by writing a product review on Amazon even with a single line It takes you just a minute but means a lot to us Thank you iSpring Warranty Registration Form ron ww o o ww ww ww OOS mew S ww y y How to reach us Local International 678 261 7611 Fax 678 530 1070 Office Hours Monday Friday 9 00 a m 5 p m EST Technical Support Hours Monday Friday 9 00 a m 5 00 p m EST Mailing Address iSpring Water Systems 3020 Trotters Pkwy Alpharetta GA 30004 USA L www 123filter com 67
12. ipe paste the black sticky pad around the hole Cut the tubing end a Back plate bit to make a 45 degree angle Front plate Slip the plastic nut and front plate on the tubing insert the tubing into the 1 4 hole on drain pipe install the back plate and tighten two screws with hex nuts while tubing remains in the hole Tighten the nut on Drain Saddle by hand Pull the tubing to check if it is secure Step 8 System Start Up Model specific steps If your model has UV stage do no plug in power until system is fully flushed 8 1 8 2 8 3 8 4 8 5 8 6 8 7 8 8 8 9 Make sure all tubings are not kinked Turn Tank Shut off Valve OFF cross Prepare a bath towel to catch water leak Turn on inline Feed Water Adapter valve AFW then slowly turn on Cold Water Supply Valve CWSV and fix leaks if any Plug in booster pump power if your model has one Within 5 minutes RO water should start dripping Let it run for at least 10 minutes This flushes the system except the tank Water is black due to loose carbon from new carbon filters It will turn clear with some air bubble Shut off RO Drinking Faucet Turn on Tank Shut off Valve Wait for two to four hours to fill up 3 2 gallon tank After two hours turn on RO Drinking Faucet to flush out all the water in the tank The water out of the faucet should be much stronger stream since the water is coming from the pressurized tank 7 10 psi The tank has fl
13. o apply pressure in circle evenly a 2 8 Be patient and deliberate It can take 20 40 minutes to drill through one inch Tips for Changing Filter Cartridges a 3 1 To ensure system performance and water purity filter cartridges must be replaced on schedule Use TDS meter periodically to check water purity a 3 2 Shut off water supply valve and tank valve open the spigot to depressurize a 3 3 Place a bucket or towel under the unit for water spills a 3 4 Use housing wrench part AWR2 to twist filter housing off in counter clockwise direction looking from the bottom a 3 5 Clean the housing using hot water and optional scent free dish soap a 3 6 Check condition of the O ring They should be replaced every 3 years to prevent leak a 3 7 Refer to Step 1 1 to install new vertical filter cartridges a 3 8 Due to suction RO membrane may be hard to pull out from housing try using tool to apply leverage photo a 3 9 The 5 and 6 stages have direction To replace them remove the tubing unscrew the fittings unwrap the new cartridge replace Teflon tape on fittings if necessary follow the gt sign on label screw the correct fitting back on each end and reconnect the tubing r a www 123filter com 678 261 7611 preted 4 sales ispringfilter com Page 7 Step 1 Install the Vertical Filters Stages 1 2 and 3 1 1 Make sure O ring is seated inside the groove on top of filter housings Food grade lubricant such as Vaseline
14. o the RO system Install the system in a sheltered environment avoid exposure to hot and cold weather or under direct sun light Once installed move the system with caution and avoid dragging the tubings Before you begin it is highly recommended to watch the video ispring reverse osmosis installation on YouTube 4 gt A Fig1 System diagram models without booster pump Optional stages UV DI ALKALINE Jen J DRAIN Air inlet TANK Drain sqddle 7 10PSI when empty YouTube Video ispring reverse osmosis installation BLOCK CARBON gacpTRR SEDIMENT CTO GAC PP Lo www 123filter com 678 261 7611 i 4 sales ispringfilter com Page 4 Fig2 System diagram models with booster pump Optional stages Flow Restrictor Auto flush Solenoid oe sjo MEMBRANE I i id 70 DRAIN I a BLACK ps A ILL TANE r PaE F 10FP I High Pressure when empty Switch R PUMP Inlet Water Solenoid Valve lt RED TO SUPPLY sft Switch BLOCK CARBON GAC FILTER SEDIMENT LTO GAC PP Fig3 Electrical wiring diagram Models with booster pump Low Pressure Switch 110 220V T Z rT d o E an i Ly i mm E r a _ Inlet Water Solenoid High Pressure Switch ae www 123filter com 678 261 7611 preted 4 sales ispringfilter com Page 5 Parts Index Cm AEON ER IE OSMOSI
15. or silicon jelly will help O ring stay in place and seal better 1 2 Filter cartridges are preserved in plastic wrap Remove the wrapping and logo sticker 1 3 When placing the filter cartridge into its housing make sure it is centered and the knob protruding from the bottom of the housing fits in the central hole of the filter 1 4 Screw the housing with filters attached onto the housing caps caps are pre attached onto the system The cap also has a center knob which should be inserted into the hole of filter cartridge Twist the housing on in clockwise direction by hand and then use housing wrench to tighten it up for about 1 4 1 2 turn Do not over tighten This can cause leaks and make it difficult to unscrew the housing when replacing filters 1 5 Follow the steps 1 1 1 4 to install the GAC and CTO filters note the second stage GAC is the only filter that must go in a certain direction Make sure the end with the rubber washer faces up thereby attaching to the housing cap Step 2 Install Reverse Osmosis Membrane 2 1 RO membrane is sealed and preserved in moisture Check for seal and remove it from plastic bag 2 2 Remove the membrane housing screw lt Push in firmly until it s even with housing cap First you will need to disconnect the white 4 tubing from elbow quick fitting on membrane housing refer to How to Use Quick Fitting section and then unscrew counter clockwise cap from A thick rubber band can b
16. th Beech Gap the lock sleeve Lock clip often in blue color and Fitting A behind body The steel teeth inside Lock sleeve lock tubing while TONTOS NAROS sleeve ispring quick fitting O ring creates permanent seal h a l 2 To connect cut tubing squarely and smoothly push Fitting body tubing into Lock sleeve firmly until it reaches the end Pull i en tubing to check if it is locked in a l 3 To disconnect remove Lock clip press Lock sleeve against Fitting body With Lock sleeve pressed pull the tubing to remove note watch our YouTube video iSpring RO Quick Fitting To connect insert tubing all the way into Lock sleeve until it is locked To pull out remove Lock clip push Lock sleeve towards Fitting body to eliminate Gap behind sleeve until tubing is unlocked Tips for Drilling a Hole on Sink or Counter top a 2 1 It s recommended to watch YouTube video how to drill a hole in granite countertop a 2 2 Choose half inch Diamond hole saw for granite and titanium drill bit for steel a 2 3 Use coolant to disperse heat Choose water for granite oil for steel a 2 4 Use 1 1 2 Suction Base Drilling Ring to hold coolant and prevent drill bit slipping on counter a 2 5 Start slowly Be cautious with slipped power drill that damages counter surface a 2 6 Set variable speed power drill at 100 200 RPM Do NOT use hammer drill on nature stone glass and ceramic a 2 7 Hold drill bit vertically and swirl a little t
17. ushed when the water flow changes back to trickle Plug in UV power and check if RO faucet turns UV on off through the Flow Sensor Switch An optional step would be to compare the TDS level between original tap water and RO water If the tap water is 100ppm the RO water should be less than 10ppm Visit 123filter com to check out a TDS Meter Check for leaks daily for the first two weeks after installation Furthermore a bucket can be put under the system in case of any leaks and a Flood Alarm can be used together for greater home and cabinet protection Lo www 123filter com 678 261 7611 preted 4 sales ispringfilter com Page 10 Model Specific Installation UV Lamp Quartz sleeve isolating UV lamp from water 1 4 quick fitting Usually no need to open the cap but _ O ring when dia G use rubber band to help u A Lamp inserted in socket Water The UV module is pre installed on the models with out _ UV It should function out of box The photos are for j Ay Flowsign Miaa Mater n better understanding about how the components are assembled and work together SOT WORK Flow Sensor wire UV C BALLAST 3 Ballast control wire gt Ice maker kit optional Jf ine valve is in OFF cross position v S ae er nl a ee Re Parris vororns EJA n i d j ay Cut the 1 4 tubing that i connects refrigerator to cold water supply line insert th 1 end of refrigerator

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書 (3.10 MB/PDF)  Bedienungsanleitung Bolzenschweißer BMS-8N - soyer  Sani Activo  DOQ-CGCRE-027  Cables Direct B5-101R networking cable  MANUAL DE USUARIO  Pentax 26785 Camera Lens User Manual  WM-EC 8 - 11 - 17 - 23 ® - Grandimpianti commercial laundry  Maytag MEDX500BW Use & Care Manual  

Copyright © All rights reserved.
Failed to retrieve file