OMB-TEMPSCAN and OMB-MULTISCAN Quick

image

Contents

1. At this point the Chart Setup Wizard dialog box opens Chart Setup Wizard Y Shari Setuy Wiese 6 Inthe Automatic Chart Creation portion of the Chart Setup Wizard dialog box click on the Create Charts button to automatically set up the default chart display Note that once your chart setup is complete you can always go back and edit the setup Next the Setup Parameters dialog box opens ioj x Setup Channel Types Alarms and Acquisition Parameters CH On a fon 4 0051 00 J c 3276 60 3276 60 12 On 0051 50 J C 3276 60 3276 60 Tajon 0052 90 J E 3276 60 3276 60 On 0052 10 J CH4 T 3276 60 3276 60 onan 7 Click on the Make All Channels Active button to enable all channels Next click on the Enable SpreadSheet Reading button to activate the display scanned data in the Reading column Then click OK to accept the settings Note also that once this parameter setup is complete you can always go back and edit the setup This time the ChartView Main Window opens At this point startup is complete ChartView Main Window 8 To start and stop data collection click on the Start Charts and Stop Charts buttons respectively Charts will begin and end scrolling accordingly Feel free to continue your own navigation and exploration throughout the application to gain familiarity with ChartView For more information on ChartView refer to the chapter ChartView in your user s manual 4 T
2. refer to the chapter Power amp Assembly in your user s manual Step 2 Check or Configure the DIP Switch Setting on the Unit 446 0940 Rev 1 0 Note TempScan 1100 or MultiScan 1200 is default configured for IEEE 488 port connection to a PC To configure the unit for the following RS 232 serial operation change the rear panel DIP switch settings as follows Otherwise to configure the unit for RS 422 serial operation or IEEE 488 operation refer to the chapter TempScan 1100 amp MultiScan 1200 in your user s manual The DIP switch is located on the rear panel of your TempScan 1100 or MultiScan 1200 unit One possible RS 232 serial setting is indicated in the following figure and table We will use this serial setting for this Quick Start For alternative serial settings refer to the chapter TempScan 1100 amp MultiScan 1200 in your user s manual Selection Microswitch Setting IEEE Address COMM SELECT 1 RS 232 168 421 HANDSHAKE H S 00 No Handshake be le HN LUNN an 1234567 89 BAUD RATE 6 7 8 101 9600 Baud CALIBRATION 9 0 Disabled kap e Ma COMM H S PARITY SERIAL SELECT BAUD RATE DIP Switch Settings for RS 232 Serial Operation January 1998 TempScan MultiScan Quick Start 1 Step 3 Connect the Unit to Your PC Note Prior to serial connection make sure that a serial COM port on your PC is available and properly configured to match the DIP switch settings above in Step 2 Do this by navigatin
3. Tempscan MultiScan auick start High Speed Temperature amp Voltage Systems RS 232C 422 TTL Alarms and Digital O Chassis Ground Screw DB9 Connector Output DB50 Connector Power Connector Power IEEE 488 DIP Trigger Master Slave Input Card Slot Switch Connector Switch Input DB25 Connector TempScan 1100 or MultiScan 1200 Rear Panel Introduction This Quick Start provides the quick steps to connect configure power up and operate a new TempScan 1100 or MultiScan 1200 unit for simple data collection You can attempt a quick start under the following conditions e You will be connecting your TempScan 1100 or MultiScan 1200 to the RS 232 serial port on your PC and configuring your TempScan 1100 or MultiScan 1200 for RS 232 serial operation e You will be using ChartView software in a Windows environment no programming required For other setups or information not covered in this Quick Start refer to your TempScan MultiScan User s Manual Hardware Setup Step 1 Check the Voltage Setting on the Unit Based on your order your TempScan 1100 or MultiScan 1200 unit was set at the voltage indicated on the sticker located on the rear panel of the unit near the power switch 105 125 or 210 250 volts AC Verify that the voltage value indicated on the sticker matches the voltage of your intended AC power supply If you need to change the AC power line selection for any reason
4. e common terminal blocks is connected to the common of the unit being measured Step 5 Install the Scanning Card into the Unit CAUTION Do not mix TempScan 1100 and MultiScan 1200 scanning cards within the same system TempScan 1100 scanning cards are designed for and supported only by the TempScan 1100 master unit Likewise MultiScan 1200 scanning cards are designed for and supported only by the MultiScan 1200 master unit Otherwise operating errors or equipment damage may occur When the channel input connections on the scanning card are ready make sure that the power switch on the TempScan 1100 or MultiScan 1200 unit is in the Off 0 position Plug the CA 1 power cable into the unit and then into the proper AC power outlet Do not connect the power lines to any devices connected to the scanning card inputs Install the scanning card into the INPUT CARD slot of the unit After the scanning card is installed connect any power lines to those devices connected to the scanning card inputs Connect any other cables Step 6 Apply Power to the System At this point the TempScan 1100 or MultiScan 1200 system can be powered up Turn on your PC Next turn on the TempScan 1100 or MultiScan 1200 unit by flipping its power switch to the On 1 position Then turn on any applicable devices connected to the scanning card inputs The POWER LED indicator on the TempScan 1100 or MultiScan 1200 front panel should light up If the ERROR LED ind
5. empScan MultiScan Quick Start January 1998 446 0940 Rev 1 0
6. g to the Windows Control Panel gt System gt Device Manager tab then clicking on Ports COM amp LPT Use a CA 47 serial communication cable PC Serial Port or equivalent to connect the Serial TempScan 1100 or MultiScan 1200 S RS 232 RS 422 serial port to an available serial port on your PC The TempScan 1100 or MultiScan 1200 end of the CA 47 cable has a DB9 connector The PC end has 2 connectors DB9 and DB25 Serial Communication Cable a Da waster unit RS 232 RS 422 Serial Connection PC to Master Unit Step 4 Connect the Channel Inputs on the Scanning Card CAUTION Use approved ESD precautions including static free work area and grounded wrist Strap when handling circuit boards and electronic components Failure to do so could cause equipment damage due to electrostatic discharge Insert the appropriate wires into the selected screw terminal sockets of your scanning card to make the channel input connections Each scanning card contains screw terminal blocks for quick and easy input connections Labelling is provided on the card for simple channel identification If necessary use the several tie down holes provided for the tie wrap strain reliefs These reliefs are used to keep wires from all the channels organized and manageable before they exit the rear panel of the unit Note When making differential voltage measurements you should insure that one of th
7. group and check that all of the programs are present Startup ChartView amp Collect Data From Windows 3 X or Windows 95 double click on the ChartView icon or select the ChartView option from the ChartView program group The ChartView Startup dialog box appears Continue to Step 2 The ChartView Startup dialog box presents you with two options Select Device or Load File Choose Select Device The Select Interface dialog box appears Chart View Startup No interface selected Retry Load File Exit The Select Interface dialog box presents you with three Select Interface options IEEE 488 RS 232 or Simulated Instrument Select RS 232 to match the configuration of your TempScan 1100 or MultiScan 1200 system Click OK Device Interface IEEE 488 RS 232 Simulated Instrument When you choose RS 232 the RS 232 Setup dialog box appears Provide information regarding Comm Port Baud Rate Parity Handshaking and Modem Make sure that Comm Peat jComm 1 s this information matches the current hardware configuration Baud Rate fI600 of the DIP switch settings Parity Hens When the dialog box information is complete click OK Hand haking Nene BI ince Ho Note For alternative serial settings make sure that you provide information for this dialog box matching the hardware configuration of the alternative DIP switch settings January 1998 TempScan MultiScan Quick Start 3 5
8. icator starts flashing refer to the chapter Power amp Assembly in your user s manual for details on power up activation errors 2 TempScan MultiScan Quick Start January 1998 446 0940 Rev 1 0 Software Setup amp Startup Step 7 1 2 446 0940 Rev 1 0 Install the ChartView Software in Windows Make a back up copy of the ChartView Release Disks Make sure that your PC fulfills the following computer requirements for successful software installation e Windows 3 X or Windows 95 For Windows 3 X a computer system with at least a 4x86 processor and at least 8 MB of RAM is required 16 MB of RAM is recommended for overall satisfactory performance For Windows 95 a computer system with at least a 5x86 or Pentium processor and at least 16 MB of RAM is required 32 MB of RAM is recommended for overall satisfactory performance If your PC does not fulfill the above requirements perform the necessary hardware upgrades or select another PC for software installation If your PC fulfills the requirements continue to Step 4 Boot up your PC according to the manufacturer s instructions Place the ChartView Back Up Release Disk 1 into the floppy drive from which you are installing typically drive A and run the A SETUP EXE program or double click its icon Follow the directions in the on screen dialog boxes When you have successfully completed the software installation you can navigate to the new ChartView program