Home
User`s Manual - EPS Bio Technology Corp.
Contents
1. Caring for your EasyPlus mini MasterDriver SMBG system does not require special cleaning Please keep the meter free of dirt dust bloodstain and water stains Follow these guidelines carefully to help you get the best performance possible Do Do Not B Make sure the meter is turned off NW Get any moisture in the test strip slot B Gently wipe the meter s surface with a soft M Spray any cleaning solution directly onto cloth slightly dampened the meter NW Put the meter under water or liquid NW Pour liquid into the meter Cleaning Your Lancing Device B To clean the lancing device wipe it with a soft cloth dampened with water and mild detergent DO NOT places the entire device under water m To disinfect the cap after cleaning place it in 70 75 rubbing alcohol for 10 minutes at least once a week Allow the cap to air dry after disinfecting 45 Maintenance And Testing CET nn Your meter needs little or no maintenance with normal use s It automatically tests its own systems every time you turn it v T a on and lets you know if something is wrong See Screen Messages and what to do about them M I M IN N 2s To make sure the display is working properly turn off the JE a meter Press and hold 69 to see the complete display All the indicators should be clear and look exactly like the picture to the left If not please contact your healthcare professional 46 Screen Messages and Troubleshooting
2. 6 and I shows itself 3 Place the meter on a flat surface like a table 4 Remove the control solution bottle cap and wipe the tip of the bottle with a tissue 21 5 Squeeze the bottle until a tiny drop forms at the tip of the bottle 6 Touch the drop to the Blood collection area at the tip of the test strip Do not put control solution on top of the test strip When you hear beeps you have enough control solution in the test strip 7 The meter starts to count down from 5 seconds the display shows Ok and then shows the test result 8 Do not remove the test strip yet Check if the reading falls within the range printed on the test strip bottle 9 Remove the test strip and throw it away after you have compared the reading to the range printed on the test strip bottle 22 Understanding Control Solution Test Results The label on your test strip bottle shows the acceptable ranges for the Control Solutions The result you get should be inside the acceptable range for the appropriate control solution level Make sure you compare the result to the correct level of control When the control solution result is inside the range on the test strip bottle your test strips and your meter are working properly If your control solution result is not inside the acceptable range printed on your test strip bottle here are some things you can do to solve the problem AN Control Solution values will be include
3. 10 C 40 C 50 F 104 F condition Hematocrit Hct 1 93 x 0 94 49 x 24 0 mm Device dimension H x W x D mm 3 5 x 1 5 x 0 6 89 0 x 38 0 x 16 5 mm 1 2 oz 34 3 grams w o batteries Running With Your Computer 1 Plug the EasyPlus mini MasterDriver meter into a USB port on your PC a 2 The display shows PC and the GlucoManager software runs automatically For more information please read GlucoManager Data Management Software GDMS User s Manual 1 Make sure you had exited from GlucoManager software otherwise DO NOT plug out meter 2 Do not insert strip while meter connect on PC 3 The suggested monitor for the software is 1024 x 768 dpi 50 Limitation The test strips are used for fresh capillary whole blood samples 1 2 DO NOT use neonate blood sample Extreme humidity may affect the results A relative humidity greater than 90 may cause incorrect results The system should be used at a temperature between 10 C 40 C 50 F 104 F Outside this range the system may get incorrect results DO NOT reuse the test strips The test strips are for single use only Red blood cell count Hematocrit Hematocrit levels between 30 and 55 will not significantly affect the results Hematocrit levels below 30 may cause higher results Hematocrit levels above 55 may cause lower results If you do not Know your hematocrit level please consult with your healthca
4. 3 Repeat step 2 to set the date and time The flashing field is the one you are currently setting When finishing the setting the display shows OK and the meter beeps 17 Using EasyPlus mini MasterDriver Blood Glucose Test Strip Use only with EasyPlus mini MasterDriver Blood Glucose Meter Run a control solution test every time you open a new box of test strips See Chapter 2 Control Solution Testing Keep the test strips in their original bottle After you take a test strip out of the bottle close the bottle immediately Use the test strip within 3 minutes after you taking it out of the bottle The test strip is for single use only Do not reuse it Write down the date on strip bottle when the strip bottle is first time opened Be sure to check the expiration date on the test strip bottle The test strip will be expired either in three months after the date of the bottle is opened or till the expiration date printed on the bottle Store the test strip bottle and your meter in a shady and arid place Store the test strips between 2 C 30 C 36 F 86 F Do not freeze Do not apply blood or control solution to the test strip before you insert it into the meter Do not touch the test strip with wet hands Do not bend cut or twist the test strips 18 Chapter 2 Control Solution Testing Why Run A Control Solution Test We recommend that you run the EasyPlus mini MasterDriver Normal control test because it lets you
5. Meter EasyPlus mini MasterDriver Blood Glucose Meter Display Buttons Tum the meter on or off Select or change information Test Strip Slot gt Insert test strip here Battery Door 14 The EasyPlus mini MasterDriver Blood Glucose Test Strip and Accessories Blood Glucose Test Strip Electrode mm Strip Insert Direction Hand Hold Area Q N Reaction Area Blood Collection Area Test Strip Bottle Control Solution Bottle m 0511412402 113 05 280 the batio immediat j te cing the hest strie ale Discard test str im rs affer first openi Expiration Date Lancing Device Sliding barrel Sleeve AST Trigger button Lancing Hub Device Cap Carrier Adjustable tip 15 Inserting Batteries 1 Open the battery door of the meter by slipping the tab in the direction of the arrow 2 Insert a battery and the meter beeps 3 Put the battery door back in place and snap it closed The meter turns on automatically 16 Setting The Time and Date First Time Use Setting the current time and date in your meter is important if you intend to use the meter memory or if you want to download your results to a computer 1 Insert a new battery the meter beeps and turns on automatically 2 The last 2 digits of the year flash at the center of the display Press C to adjust the year and press 69 to confirm the setting
6. know that your meter and test strips are working properly to give you reliable results You should run the control solution test when B You use the EasyPlus mini MasterDriver Blood Glucose Meter for the first time You open a new bottle of test strips m You think the meter or test strips may be working incorrectly B You drop the meter m You have repeated a test and the test results are still lower or higher than expected m You are practicing the test procedure Professional users are instructed to follow federal state and local guidelines 19 About The Control Solution Use only with EasyPlus mini MasterDriver test strips Write the date you opened the control solution bottle on the bottle label The control solutions are good for three months from the date the bottle is opened or until the expiration date on the bottle whichever comes first Do not use a control solution that is past the expiration date Control solution can stain clothing If you spill it wash your clothes with soap and water Close the bottle tightly after every use Left over control solution should not be added back into the control bottle Store control solution at room temperature between 2 C 30 C 36 F 86 F Do not freeze 20 Running A Control Solution Test You need the meter a test strip and control solution 1 Put a test strip into the meter in the direction of the arrow 2 The meter beeps and turns on automatically The icon
7. EasyPlus mini MasterDriver Self Monitoring Blood Glucose System User s Manual Dear EasyPlus mini MasterDriver SMBG System Owner Thank you for choosing the EasyPlus mini MasterDriver Self Monitoring Blood Glucose SMBG System We designed this system to be reliable use friendly and efficient to help you monitor your blood glucose on a regular basis Please read this manual thoroughly before you begin testing This manual provides you and your diabetes care team with important information and step by step direction to use the EasyPlus mini MasterDriver Self Monitoring Blood Glucose System Once again thank you for choosing the EasyPlus mini MasterDriver SMBG System Intended Use The EasyPlus mini MasterDriver Self Monitoring Blood Glucose Test System is intended for the quantitative measurement of glucose in fresh capillary whole blood from fingertips palm or forearm Testing is done outside the body n Vitro diagnostic use It is indicated for self testing over the counter OTC by persons with diabetes or in clinical settings by healthcare professionals as an aid to monitor the effectiveness of diabetes control A Although the Master Driver SMBG System is easy to use you may need to consult your healthcare professional this may be your doctor pharmacist or diabetes nurse educator for instructions on how to use the system Only the correct use of the system will ensure accurate results Standard Acces
8. Never make treatment decisions based on an error message If you have any concerns please contact your healthcare provider Message What it means Humidified Used strips The meter has detected a problem with the test strip Low power The meter batteries do not have enough power to perform a test Volume detector error The volume of blood or control solution is NOT enough What to do Repeat the test with a new strip Refer to pages 28 29 for information on sample application Replace the new batteries Replace with a new strip If Err appears again please contact your local dealer 47 Message What it means Test result is higher than 630 mg dL 35 0 mmol L The test result is lower than 20 mg dL 1 1 mmol L The meter is connecting to the computer What to do Re check your glucose level If the result is HI again obtain and follow instructions from your healthcare professional without delay This may require immediate treatment according to your healthcare professional s recommendations Although this message could be due to a test error itis safer to treat first and then do another test You can start to use the embedded software Please read GlucoManager Data Management Software GDMS User s Manual for more information 48 Chapter 6 Technical Information Specification Range 20 630 mg dL 1 1 35 0 mmol L Test time 5 seconds Sseconds OO Operating
9. ate the lancing device 4 Hold the device against forearm and increase pressure until the blood sample size is sufficient 33 Running a Blood Glucose Test with Blood from Your Palm 1 Massage the puncture area of palm for a few seconds 2 Press and hold the device with one clear adjustable tip against the palm 3 Press the trigger button to activate the lancing device 4 Hold the device against forearm and increase pressure until the blood sample size is sufficient Check with your healthcare professional before testing other sites than fingertip 34 Discarding Used Lancets 1 Unscrew and remove the cap 2 Without touching the used lancet stick the lancet tip into its protective cover 3 Pointing the lancing device toward a container for sharp or biohazard material slide the ejection button down to release the covered lancet into the container 35 Understanding Your Test Results The EasyPlus mini MasterDriver Blood Glucose test strips are plasma referenced and calibrated for easier comparison to lab results The normal fasting blood glucose range for an adult with diabetes is 70 130 mg dL 3 9 7 2 mmol L Two hours after meals the blood glucose range for an adult with diabetes is less than 180 mg dL 10 0 mmol L For further queries about diabetes please consult your healthcare professional for the blood glucose range appropriate for you Reference American Diabetes Association Standa
10. d in the memory and averages Refer to the section Viewing amp Deleting Test Results to delete the control solution values before averaging vour test results 23 Troubleshooting Checks Was the test strip exposed to open air for a long period of time Does test strip cap close tightly Or was test strip cap left open Is the meter functioning well Is the control solution expired or contaminated Were test strips and control solutions stored in cool dry places Did you follow the testing steps properly Action If yes repeat the control test with properly stored Strips If the cap was not tight or the bottle was left uncapped open a new bottle of test strips Do not reuse the strips from the affected bottle You can use control solution to verify the meter s functions Chapter 2 If yes replace with new control solution to check the performance of SMBG system If no repeat the control test with properly stored strips or control solutions Read Chapter 2 Control Solution Testing and test again Stop using the meter if you continue to obtain the inaccurate results If you have questions or need assistance please contact your healthcare professional 24 Chapter 3 Testing Your Blood Glucose Using The Lancing Device B The best depth setting is the lowest number that draws enough blood for a test Try different settings to find the one that s right for you B Please do not share your lancing devic
11. e with anyone And always use a new sterile lancet Lancets are for one time use only Used test strips and lancets are considered bio hazardous waste in accordance with local regulations and should be handled as if capable of transmitting infection Users may discuss methods for disposing of used test strips and lancets with their doctor 25 Inserting A Lancet Into The Lancing Device You must first load the lancet into the lancing device to get it ready for use 1 Unscrew the Cap 2 Insert the lancet into the lancing 3 Recap the front cap device firmly then twist off the protective cover N Lancets are for use only and a new sterile lancet should be used each time you perform a test 26 4 Select the desired 5 Pull on the sliding barrel of the 6 Set the lancing device penetration depth lancing device until it clicks and aside until later in the then release test Now the lancing device is ready N Do not prick your finger until your meter and strip are prepared 1 Select 1 2 for soft or thin skin 3 for average and 4 5 for thick or calloused skin 2 Lancing device and lancets are not to be shared between users Sharing lancing devices and lancets may transmit blood borne pathogens such as viral hepatitis 27 Running A Blood Glucose Test With Blood From Your Fingertip 1 Wash your hands with soap and warm water Rinse and dry thoroughly 2 Put a test strip into the meter in the direction of the ar
12. er Blood Glucose Test Strip andAccessorie 15 inserting BP EET OT DENM 16 Setting The Time And Date errar erree nennen nennen nennen nn nnne nnn 17 Using EasyPlus mini MasterDriver Blood Glucose Test Strip 18 Chapter 2 Control Solution Test occcccccccccccocccoonnccncnnnnncconononononnnnnnnnnnonononononnnnnnnnnnnnnnns 19 Why Run a Control Solution Test cccccoocccccccccncnnononcnnnononcnononnoncnnonnnnnnnnnnnrnnnnonannononnnccnnnnnnos 19 About The Control Solution cccccscceccsseeccsseecesseeceseeceaseeceaseeseasececaseeecaueeecauseessuseessuseessaes 20 Running A Control Solution Test sees nnne nnne nnne nnn 21 Understanding Control Solution Test Results eee erere anna 23 Chapter 3 Testing Your Blood Glucose eee nennen 25 Using The Lancing DEVICE riadas kai 25 Inserting A Lancet into the Lancing Device oooccccocccccncccncnoccncnncononncononncononncnncnnnonnonrnnnnoninonnos 26 Running A Blood Glucose Test With Blood From Your Fingertip ccccocccccccnoccccnnccconnncnnno 28 Alternate Site Testing AST as 30 Running A Blood Glucose Test With Blood From Your Forearm ii 33 Running A Blood Glucose Test with Blood from Your Palm eee 34 Discarding EEE ea 35 Understanding Your Test Results rrerrnnnre
13. ery dehydrated urinating frequently have low blood pressure in shock or hyperosmolar hyperglycemic nonketotic coma HHNKC you may get a test result that is lower than what your blood glucose really is If you think you are dehydrated call your doctor right away m If you have followed the steps in the user s manual but still have symptoms that don t seem to match your test results or if you have questions please contact your healthcare provider m Please read your test strip instructions carefully for additional health related information Warning for potential biohazard Healthcare professionals using this system on multiple patients should handle all products or objects in contact with human blood carefully to avoid transmitting viral disease even after cleaning Explanation of Symbols ek LOT Bach os n vitro diagnostic medical 3V CR2032 x 1 battery only evice Authorized representative in the Sufficient for A European Community C This product meets the _ E fe ter Directive 98 79 EC in vitro diagnostic medical devices Pun mg dL Poa BEG E ME WEE 30 1 Button Button Battery N The unit of Blood Glucose Meter is set at mg dL Table of Contents Chapter 1 Understanding Your Meter coooooooccccccnonococonooconccncnnnnnononnnononncnnnnnonnncnonnnos 14 The EasyPlus mini MasterDriver Blood Glucose Meter cccccccsessseseseseseseseseecereceeeeeeenen 14 The EasyPlus mini MasterDriv
14. f high blood glucose contact your healthcare professional instantly B Ifthe result does not match how you feel follow the steps under Unusual Test Results 38 Below 60 mg dL 3 33 mmol L What It Means The test result is lower than reference normal range 70 130 mg dL or 3 89 7 22 mmol L Symptoms Sweating trembling blurred vision rapid heartbeat tingling or numbness around mouth or fingertips What to Do B If you are experiencing any of these symptoms test your blood glucose B Ifthe result displayed is below 60 mg dL 3 33 mmol L and you have symptoms of low blood glucose contact your healthcare professional instantly B Ifthe result does not match how you feel follow the steps under Unusual Test Results 39 Comparing Your Meter Result To A Lab Result A common question is how the blood glucose results on your meter compare to the lab results Your blood glucose can change quickly especially after eating taking medication or exercising If you test yourself in the morning then go to the doctor s office for a blood glucose test The results will probably not match even if you are fasting This is typically not a problem with your meter it just means that time has elapsed and your blood glucose has changed If you want to compare your meter result to the lab result you must be fasting Bring your meter to the doctor s office and test yourself by fingertip within five minutes of having blood drawn from y
15. fter taking insulin a Two hours or more after exercise 30 Do NOT use AST if You think your blood glucose is low You are unaware of hypoglycemia Your AST results do not match the way you feel You are testing for hyperglycemia Your routine glucose results are often fluctuating Fingertip test only If sick If blood glucose is low After exercising Two hours or less after eating When you have just taken insulin After injecting rapid acting insulin two hours or less If you often do not notice when your blood glucose is low do a fingertip test 31 AST Results If the blood glucose test result from the alternate site test does not match how you feel do a fingertip test to confirm the result again Do NOT change your treatment just because of an alternate site result do a fingertip test to confirm the result A Talk with your healthcare professional before you test with your palm or forearm Do NOT ignore symptoms of high or low blood glucose Fingertip samples are able to show the rapid change of glucose faster than forearm samples Do NOT change your treatment just because of a result 32 Running a Blood Glucose Test with Blood from Your Forearm Please use the clear cap with the lancing device for AST testing 1 Massage the puncture area of forearm for a few seconds 2 Press and hold the device with clear adjustable tip against the forearm 3 Press the trigger button to activ
16. nal purchaser for a period of 3 years from the date of purchase This means during the warranty period if your Self Monitoring Blood Glucose System does not work for any reason other than obvious abuse EPS will replace it with a new system or an equivalent product free of charge 54 Lancing Device Meets the requirements of MDD 93 42 EEC Manufacturer STERILANCE MEDICAL SUZHOU INC No 32 Xinlian RD Pingjiang Suzhou P R China 215031 TEL 0086 512 67217661 FAX 0086 512 67217663 E mail guopings xinda medical com Lancet Meets the requirements of MDD 93 42 EEC Manufacturer SAE HAN MEDICAL CORP 700 113 PUB GOT DONG IL SAN GU GOYANG CITY KYUNGGI DO KOREA TEL 82 31 923 4330 FAX 82 31 923 4331 E mail saehan saehanmed com 55 EC REP Obelis s a 34 Av de Tervuren bte 44 B 1040 Brussels Belgium TEL 32 2 732 59 54 FAX 32 2 732 60 03 E mail mail obelis net C 0537 P N 718039000_0373_02 56
17. our arm by a healthcare professional Keep in mind that the lab could use different technology than EasyPlus mini Master Driver blood glucose meter and that blood glucose meters for self testing generally read somewhat lower or higher than the lab result For accuracy and precision data and for important information on limitations see the instructions that come with your test strips 40 Chapter 4 Meter Memory Setup Memory Storing Test Results Your meter stores a maximum of 480 test results with the time and date of the test You can review them at any time When the memory is full the oldest result is dropped as the newest is added so it is very important to have the correct time and date set in the meter A 1 Do not change your therapy based on one individual result in memory 2 The memory is not lost when you replace the battery You do need to check that the time and date are still correct See Section Setting the time and date in Chapter 1 3 Once 480 results are in memory adding a new result causes the oldest one to be deleted 4 Control Solution values will be included in the memory and averages Refer to the section Viewing amp Deleting Test Results to delete the control solution values before averaging your test results 41 Viewing amp Deleting Test Results 1 Press to turn the meter on 2 Press O to enter memory mode The meter shows the total number of the stored results first and then sho
18. rds of medical care in diabetes Table 10 Diabetes care 2011 Vol 34 Suppl 1 S21 36 Unusual Test Results If your test result doesn t match the way you feel please follow these steps 1 Runa control solution test Chapter 2 Control Solution Testing 2 Repeat a blood glucose test Chapter 3 Testing Your Blood glucose 3 If your test results still don t reflect the way you feel call your healthcare professional immediately 1 Extremely high humidity may affect the test results A relative humidity greater than 90 may cause inaccurate results 2 Hematocrit below 30 may cause higher results Hematocrit above 55 may cause lower results 3 Some studies have shown that electromagnetic fields may affect results Do not test near an operating microwave oven 37 Symptoms Of High Or Low Blood Glucose Being aware of the symptoms of high or low blood glucose can help you understand your test results and decide what to do if they seem unusual Here are the most common symptoms Greater than 240 mg dL 13 33 mmol L What It Means The test result is higher than reference normal range 70 130 mg dL or 3 89 7 22 mmol L Symptoms Fatigue increased appetite or thirst frequent urination blurred vision headache general aching or vomiting What to Do B If you are experiencing any of these symptoms test your blood glucose B Ifthe result displayed is greater than 240 mg dL 13 33 mmol L and you have symptoms o
19. re professional Altitude up to 3048 meters above sea level has no effect on readings 51 Healthcare Professionals Please note these additional Limitations 10 11 Patients undergoing oxygen therapy may have inaccurate results If the patient has the following conditions the result may fail Severe dehydration Severe hypotension low blood pressure Shock 4 Astate of hypoglycemic hyperosmolar state with or without ketosis Lipemic samples Cholesterol level up to 500 mg dL and triglycerides up to 3 000 mg dL do not affect the results Grossly lipemic patient samples have not been tested and are not recommended for testing with EasyPlus mini MasterDriver Glucose Meter Critically ill patients should not be tested with home use blood glucose meters Interfering Substances depend on the concentration The below substances up to the test concentration will not affect the test results 52 Interfering Substance Test Concentration Bias at 50 5 Bias at 250 5 Bias at 500 5 mg dL 53 Device Information EasyPlus mini MasterDriver SMBG System EasyPlus mini MasterDriver Blood Glucose Test Strips EasyPlus mini MasterDriver Blood Glucose Meter EasyPlus mini MasterDriver Normal Control Solution EasyPlus mini MasterDriver High Control Solution Manufacturer EPS BIO TECHNOLOGY CORP No 8 R amp D RD Ill Hsinchu Science Park Hsinchu Taiwan 30077 Warranty EPS warrants the origi
20. rnnnnernnnnernnnnnvnnnnnnennnnnennnnnennnnnennnnnenvnnnennnnnennnnnnennnnne 36 STERN 37 Symptoms of High or Low Blood Glucose eee erererea nennen 38 Comparing Your Meter Result To A Lab Result eee erer aeee 40 Chapter 4 Meter Memory Setup eee rererer eae rerereeae rea nani 41 Memory Storing Test Resull RR ela dere 41 Viewing amp Deleting Test Results ooooncccooconnnccccocnnnoconocononconnnononncnnnononnnnnnononnnnnonannnnnnonos 42 Chapter 5 Maintenance And Troubleshooting ren 44 Inserting AAA OR OA E ENER 44 Cleaning Your Meter E tit 45 Cleaning Your Lancing Device ooccccconnnnccccnconcncnnncononcnnnnononncnnnnnnnnrononnnnnnnnnnnnnnnnrnnnranenannnnnnss 45 Maintenance And Testing ccccocnccononccononnnononononanononanononnnnnnnannnnnannnnnnnnnnoncnnnnnonnnonnnrnnnnnenononos 46 Screen Messages And Troubleshooting cccccccccceseeeeeeeeeeeeeeeeeseeeeseeeeeeeseeeeeeesaeeeeeeaseseeeesanes 47 Chapter 6 Technical Information cccccccccccccconoconncicononnncnononoononnnnnnnnnnonononononnennnnnnnnnnnnnns 49 o EN OE MK 49 Running With Your Computer rrrrnannrnnrnnnnnvrrnnnnrnnnnnnnrrnvrnnnrrnrnnnnsnnnnnnnssnsnnnsnennnnnnsnnnnssarnnnnnnsee 50 Tes 019 REE ND NE 51 BENT Ma 61110051 0 EEE EEE EE EEE 54 EE AA e T 54 Chapter 1 Understanding Your
21. row The meter beeps and turns on automatically 3 When the blood drop flashes on the display using the lancing device 4 Hold the lancing device firmly against the side of your finger Press the trigger button Then remove the lancing device from your finger 28 5 Gently squeeze and or massage your fingertip until a round drop of blood on your fingertip 6 Touch the blood drop at the tip of the transparent window of the test strip Do not put blood on top of the strip When you hear beeps you have enough control solution in the test strip Be sure to get enough blood in the test strip Otherwise an inaccurate reading may result 7 The meter starts to count down from 5 seconds the display shows Ok and then shows the test result 8 Remove the test strip and the meter turns off automatically 29 Alternate Site Testing AST Understanding Alternate Site Testing What is AST What is the advantage of AST Besides the fingertip you can test the You have the option of testing other places forearm on your body besides the fingertip Consult your health care professional before you begin using the forearm or palm for testing Blood glucose test results obtained from your forearm or palm may differ significantly from fingertip samples We strongly recommend that you Do AST ONLY in the following intervals E In a pre meal or fasting state more than 2 hours since the last meal a Two hours or more a
22. sories Your new EasyPlus mini MasterDriver Blood Glucose meter and accessories work together to measure the amount of glucose in your blood The system includes e Blood Glucose Meter e AST Lancing Device Cap Test Strip x 10 ct e User s Manual e Normal Control Solution e Quick Reference Guide e Carrying Case e Log Book e Control Solution Instructions e Test Strip Instructions Lancet x 5 ct e CR2032 Battery x 1 e Lancing device Why is it so important to test blood glucose regularly Testing your blood glucose regularly can make a big difference in how you manage your diabetes every day We ve made this SMBG system as simple as possible to help you to use it regularly Your meter is easy to use and you can adjust the lancing device for your comfort Do you need Help If you have questions or need assistance please contact your healthcare professional Important Information About Your New MeterDriver EasyPlus mini MasterDriver blood glucose meter is designed and approved for testing fresh capillary whole blood samples from your fingertips palm and forearm The meter is for in vitro diagnostic use ONLY for testing outside the body It should not be used to diagnose diabetes EasyPlus mini MasterDriver blood glucose meter can only be used with EasyPlus mini MasterDriver Blood Glucose Test Strips Other test strips will give inaccurate results Testing is not valid for neonatal blood specimen Do not disassemble
23. the meter as this may cause damage to the components resulting in incorrect reading Disassembling the meter will also void the warranty Always keep the meter clean and store it in a safe place Protect the meter from direct sunlight to ensure a longer lifespan You should not store the meter and test strips in a car or a bathroom or refrigerator Keep the meter test strips and lancing device away from children and pets You should not test critically ill patients with home use blood glucose meters Elevated levels of acetaminophen uric acid gentisic acid levodopa dopamine ascorbic acid and methyldopa may affect results Incorrect results may occur when performing the test If you believe you are not feeling well please contact your healthcare professional Remove batteries if the meter will not be used for one month or more Warning for potential biohazard Healthcare professionals using this system on multiple patients should be aware that all products or objects that come in contact with human blood even after cleaning should be handled as if capable of transmitting viral disease A Consult with your healthcare professional before testing on your palm or forearm Do not touch the strips with wet hands Do not use expired strips the expiration date is shown on the bottle Do not bend cut or twist the strips Altitude up to 3 048 meters above sea level has no effect on readings Health Related Information m lf you are v
24. ws the latest result 42 4 To delete a test result press C for 3 seconds When display shows dEL press 69 to confirm the deletion Or press C to cancel the deletion and go back to the total number of the stored results 5 Press 69 for 1 second to go back to the total number of the stored results 6 Press 69 for 3 seconds to turn off the meter or the meter turns off automatically in 90 seconds 43 Chapter 5 Maintenance and Troubleshooting Inserting Battery The meter uses one CR2032 Battery Battery will normally last for more than 1000 tests Other types of CR2032 batteries are also acceptable but the capacity of test times may differ Insert the battery when you first use the meter or replace with new battery when the LP low power message and the low battery symbol appear on the display The meter will not turn on the first time the battery is inserted Please press and hold button or insert the test strip to turn your meter on The meter will turn off automatically Or you can press and hold 69 button to turn your meter off N 1 The meter won t delete earlier records after you replace the battery 2 You should reset the time and date again after you replace the battery 3 CR2032 Lithium Battery is available at most stores You may take the old battery with you for replacement 4 Remove the battery when you will not be using the meter for one month or more 44 Cleaning Your Meter