Model 11 Syringe Pump Series User`s Manual

image

Contents

1. 0 05 95 130 VAC 220 260 VAC 115 230 VAC 50 60 Hz via internal selector switch 15 W 0 25 A fuse 11 4 x 22 9 x 11 4 cm 4 1 2 x 9 x 4 1 2 in 2 1 kg 4 6 lb Actual force is higher Not recommended for applications more than 25lbs of force Description and Features KAA Harvard Apparatus Model 11 Syringe Punp Series User s Manual The Pump 11 has been designed as a low cost high precision single syringe infusion pump with moderate back pressures The pump can take one or two syringes of any make any size from 0 5 ul to 10 ml The diameter of the syringe s is entered via the keyboard and the internal microprocessor calculates the cross sectional area to calibrate the pump for that syringe The microprocessor automatically determines if the flow rate is to be expressed in ul hour or ml hour depending on the syringe size Non volatile memory stores the last syringe diameter and flow rate used A unique Power Failure Mode selector can be set to either turn the pump off in the event of power failure or to resume pumping when power resumes Easy To Use Only two entries requried syringe Inside Diameter ID and the flow rates The Flow rate can be changed while the Pump is running Nonvolatile Memory The pump remembers its last syringe size and flow rate used Momentary Loss of Power In a power failure the Pump can either RESUME or STOP pumping when power is returned Harvard Apparatus Model 11 Syringe Punp Ser
2. Stainless Steel Terumo SGE Scientific Size ___ Diameter Size ___ Diameter Glass Engineering 8 cc 9 525 mm 3cc 8 95 mm Size Diameter 20 cc 19 130 5 13 00 25 ul 0 73 mm 50 cc 28 600 10 15 80 50 1 03 100 cc 34 900 20 20 15 100 1 46 30 23 10 250 2 30 Becton Dickinson 60 29 10 500 3 26 Plastic Plasticpak 1 0m 4 61 mm Size Diameter Sherwood 2 5 7 28 icc 4 78 mm Monoject Plastic 5 10 30 3 8 66 Size Diameter 10 14 57 5 12 06 1 cc 4 65 mm 10 14 50 3 8 94 Hamilton 20 19 13 6 12 70 Microliter 30 21 70 12 15 90 Series Gastight 50 60 26 70 20 20 40 Size Diameter 35 23 80 5 ul 0 103 mm Air Tite 60 26 60 0 1457 All Plastic 140 38 40 0 206 Size Diameter 0 3257 25cc 9 60 mm Popper amp Sons Inc 0 460 5 0 12 45 Perfektum Glass 0 729 10 15 90 Size Diameter 1 031 20 20 05 0 25cc 3 45 mm 1 46 30 22 50 0 5 3 45 2 3 50 29 00 4 50 3 26 8 92 4 61 mm Unimetrics 8 99 i 7 28 Series 4000 amp 5000 11 70 10 3 Size Diameter 14 70 14 57 10 ul 0 460 mm 19 58 23 0 25 0 729 22 70 32 6 50 1 031 29 00 100 1 460 35 70 250 2 300 500 3 260 1000 4 610 Harvard Apparatus Model 11 Syringe Punp Series Users Manual Appendix B Nominal Max Min Flow Rates 10 Ee f Various Syringes Actual Limits Will Vary Depending on Manufacturer 4 Nominal Nominal y Syringe Diameter 3 Size mm 0 5 ul 0 10 0 01 0 45 Btu 0 15 0 01 1 07 2H 0 21 0 01 215 H 5 ul 0 33 0 01 5 38 g 10 ul 0 46 0 01 10 55 2
3. will vary Warranty Harvard Apparatus warranties this instrument for a period of one year from date of purchase At its option Harvard Apparatus will repair or replace the unit if it is found to be defective as to workmanship or material This warranty does not extend to damage resulting from misuse neglect or abuse nor mal wear and tear or accident This warranty extends only to the original customer purchaser IN NO EVENT SHALL HARVARD APPARATUS BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states do not allow exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you THERE ARE NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE OR OF ANY OTHER NATURE Some states do not allow this limitation on an implied warranty so the above limitation may not apply to you If a defect arises within the one year warranty period promptly contact Harvard Apparatus Inc 84 October Hill Road Holliston Massachusetts 01746 1371 using our U S only toll free number 1 800 272 2775 or dial 508 893 8999 Goods will not be accepted for return unless an RMA returned materials authoriza tion number has been issued by our customer service department The customer is responsible for shipping charges Please allow a reasonable period of time for com pletion of repairs replacement and return If the unit is replaced the replacement unit is covered only for t
4. 5 ul 0 73 0 01 25 85 50 ul 1 03 0 01 52 91 100 ul 1 46 0 01 100 0 250 ul 2 30 0 01 260 0 500 ul 2 30 0 01 520 0 1 000 ul 3 26 0 01 1 05 1ml 4 61 0 01 1 13 2 ml 7 28 0 01 4 14 2 5 ml 7 28 0 01 3 73 3 ml 8 66 0 101 3 73 5 ml 10 30 0 05 7 20 10 ml 14 57 0 05 10 40
5. Model 11 Syringe Pump Series User s Manual Model 11 Virtually Pulse Free Syringe Pump 55 2111 Harvard Apparatus Model 11 Syringe Pump Series User s Manual Table of Contents Warranty and Repair Information s 2 SPECIICAUONSG mua 3 PO AQUUIGS ai casscfussinnensunndsaiwaiownicedeannaend 4 Initial StU ii ia 5 Loading Syringe wi 6 SU EA SAA UA Aa 7 Pump Operations sinsiiiiveisieinesacwsesisniannaneciadinennansas 7 Turn PUMP ia 7 FUNCUON KOSA 7 Entering Syringe Diameter S cccessseeeees 7 Entering Flow Rate S cccccccccssssssseesssseeeeeeeeeeeeee 8 Press Stal a ieisianssacctvnitiweswadissssencenasaceiasannaneedeontansanie 8 Check Syring uu ia 9 Power Fal ii aiaa 8 Changing Rates wis loceiscsicissiinseinrcansieteaewenereniandadinite 8 Maintenance nan cnssciseannetansiandnndsnssniuidsnsnansadwadsdanansiins 8 Microliter Syringe S siviiessssatstinciaisntasssnnnstunncenweeninas 8 Appendix A Table of Popular Syringe Diameters 9 Appendix B Table of Nominal Min and Max Flow Rates 10 Warranty and Repair Information AAA Harvard Apparatus Model 11 Syringe Punp Series User s Manual Serial Numbers All inquires concerning our product should refer to the serial number of the unit The serial number is located on the rear of the chassis Calibrations All electrical apparatus is calibrated at rated voltage and frequency While the flow will stay calibrated the peak
6. ange from one mode to other press UP or DOWN keys then press ENTER Changing Rates If pump is running at an existing rate it will continue to do so while new rate is being entered As soon as ENTER key is pressed pump will instantly change to new rate Maintenance No special maintenance is required other than keeping pump clean and dry Avoid liq uid spills that may find their way into electronics A container of grease is provided for periodic lubrication of lead screw as well as a bottle of oil for periodic lubrication of two stainless steel guide rods It is important to keep these guide rods clean 10 Fuse Replacement Make sure power cord is disconnected from main supply before replacing fuse Locate fuse holder on rear panel of pump Use straight blade screwdriver to turn gray fuse carrier counter clockwise remove fuse from carrier Replace fuse and fuse carrier For continued fire protection replace fuse only with 250V fuse of specified type and rating 3AG 1 4 AMP 250V SLO BLO 11 Use of Microliter Syringes Pump 11 will take microliter syringes down to 0 5 ul size These syringes have fine wire plunger that will be damaged if plunger hits bottom Pump is equipped with adjustable collar on one of guide rods Adjust collar so pusher stops before plunger hits bottom WARNING Use in manner not specified by the manufacturer may impair the protection provided by the equipment Appendix A Common Syringe Diameters
7. e blink ing and advance to the next digit which will blink To enter the diameter of your syringe identify the make and size of your syringe Referring to Table 1 determine the inside diameter in mm If your syringe is not listed then measure the diameter and record for future use Enter the syringe diam eter using the following example of a Becton Dickinson plastic syringe plastipak size 10 cc The chart in Appendix A shows the diameter to be 14 50 mm This is the number we want to enter into the pump a Turn on power using switch in rear of pump display should blink b Press SET followed by DIAM The previously used diameter will appear on display with left hand digit blinking The mm dia legend to right side of display will be illuminated indicating that display is reading diameter Use UP and DOWN keys to set desired number on left hand digit Using our example of 14 50 set left hand digit to 1 and press SET key The 1 will now stop blinking and the next digit to right will blink Using the exam ple and UP and DOWN keys set second digit to 4 Again press SET key and next digit will blink Continue doing this until 14 50 is displayed c Press ENTER key to put this diameter into memory d Display will now revert to show RATE e Verify that correct diameter has been entered by pressing and holding DIAM key Display should read what was entered 26 70 Harvard Apparatus Model 11 Syringe Punp Series User s Manual Op
8. erating the Pump 8 a 4 5 Enter Flow Rate a Press SET to put display in set mode b Using UP and DOWN keys enter desired flow rate Press ENTER key to put rate into memory c With rate and diameter information entered the microprocessor makes the fol lowing decisions 1 If syringe size is small then flow rate display will read ul hr 2 If larger syringe is selected then display will read ml hr 3 If flow rate selected is beyond capabilities of pump either by being too fast or too slow display will indicate OOR standing for out of range d Table 2 on page 11 contains maximum and minimum possible flow rates and relevant units for each size syringe Press Start Start infusion by pressing START STOP key Display will indicate numerical flow rate units of flow and run light will be illuminated Check Syringe Often Pump 11 will not shut itself off when syringe hits bottom or is otherwise overloaded When stalled run light will continue to be illuminated Check syringe from time to time to make sure it is infusing Power Failure In the event of a momentary or prolonged power failure Pump 11 can be set to either a Resume pumping when power is returned PF 1 with run light illuminated b Not start pumping when power is resumed PF 0 In either situation display will flash indicating a power failure To set power failure mode press SET and RUN STOP Display will read PF 0 or PF 1 with 0 or 1 blinking To ch
9. he remainder of the original warranty period dating from the purchase of the original device This warranty gives you specific rights and you may also have other rights which vary from state to state Repair Facilities and Parts Harvard Apparatus stocks replacement and repair parts When ordering please describe parts as completely as possible preferably using our part numbers If practi cal enclose a sample or drawing We offer a complete reconditioning service CAUTION This pump is not registered with the FDA and is not for clinical use on human patients AN CAUTION Not for clinical use on human patients 3 Harvard Apparatus Model 11 Syringe Pump Series User s Manual Specifications Virtually Pulse Free VPF Dual Syringe Pump 11 Type Syringe Size Flow Rate Range Minimum Maximum Calibration Display Nonvolatile Memory Maximum Force Microprocessor single or dual syringe infusion only 2 plastic or glass from 0 5 ul to 10 ml 0 01 pl hr with 0 5 ul syringe 10 40 ml hr with 10 ml syringe Automatic enter syringe ID up to 15 9 mm 4 digits and 4 LED indicators Storage of all settings 11 35 kg 25 Ib Drive Motor 7 5 step geared 300 1 0 025 micro step angle motor Step Rate Minimum 1 pulse in 27 6 sec Maximum 200 steps sec Pusher Advance Step 1 322 um Dynamic Range 5461 to 1 Leakage to Ground Ground Resistance Voltage Range Power Size HxWxD Weight Typically lt 10 pA Typically lt
10. ies User s Manual Initial Setup 5 a di Read the entire manual Pumps are shipped from the factory with an American line cord with three wire molded power connector and the pump set for 110 to 220 VAC To change volt age locate the voltage selector switch by removing 4 screws on the bottom panel 2 on each end of the pump Identify the voltage selector switch located directly below where the line cord enters the pump Using a screw driver turn the switch and set it to the voltage being used If other than 115V 60 Hz is being used the plug must be cut off and an appropriate plug installed observing the polarity of the international line cord used Brown High Blue Neutral Green Ground Turn on main power switch located directly above the line cord on the rear panel The display will now illuminate indicating that the power connections are correct The flashing number displayed is the current flow rate Flashing indi cates that power has just been applied Voltage selector switch and fuse for 110 220V Loading Syringes KAN To Load the Syringe a Release the syringe pusher by pressing the bronze button on the side of the pusher b While holding the bronze button in slide the pusher to the left c Raise the spring loaded stainless steel syringe retainer and swing it out of the way d Lay the loaded syringe in the V shaped holder e Swing the retainer so it holds the syringe in place f M
11. ove the pusher so it makes contact with the head of the syringe Harvard Apparatus Model 11 Syringe Pump Series User s Manual Harvard Apparatus Model 11 Syringe Pump Series User s Manual Operating the Pump 7 i 1 Turn Pump ON Locate the main power switch at the rear of the pump and turn it to the ON posi tion The display will now blink indicating that power is being supplied to the pump Press any key to stop blinking Pump is ready for operation Function Keys Refer to the colored keypad at the front of the pump to identify the following func tions starting from the right mm hr ul hr mm dia v l run A set diam fenter stop run 9 RUN STOP This turns the pump motor on and off ENTER This key enters data that is on LED display into memory of pump DIAM Used to enter syringe diameter st Ascending and descending keys are used to change numbers on display s Up key makes numbers increase t Enter Syringe Make amp Size Down Key makes numbers decrease SET This key is used to select which digit of the display is to be adjusted Each time the set key is pressed the digit on the display is moved one step to the right It is used in conjunction with the ascending and descending keys Each digit starting from the left will blink When it reads the correct value the set key will stop th