1. Phaesun stand alone solar solutions Wind Solar Hybrid Controller User Manual Model HY C10 24AWM and HY C10 48AWM Phaesun eS stand alone solar SOMUONS Phaesun GmbH Br hlweg 9 87700 Memmingen Germany Telefon 49 8331 990 42 12 info phaesun com www phaesun com ce Phaesun Stand alone solar solutions 1KW Wind Solar Hybrid Controller User Manual Notices 1 A Battery reverse connection is forbidden 2 Battery virtual connection or damage is one main factor of malfunction Please check battery voltage and connection status weekly clear rust on positive negative terminal in time use lead terminal if available 3 If the malfunction is not easy to eliminate or reason unclear please write down the phenomenon in detailed record and contact manufacturer for help in time Installation Environment 1 The equipment should be installed indoor where is well ventilated 2 Avoid exposing the apparatus under direct sunshine exposure rain moist acid mist and dust 3 Allow at least 20 inches 0 5 m distance from battery 4 Ambient Temperature is 20 55 C Ambient Humidity is 35 85 RH no condensing 5 Addo not install the equipment in a compartment with flammable liquids such as gasoline or explosive vapors Be ware of the flame and the spark General Description The wind solar hybrid controller is an intelligent control device which can control wind turbine and solar panel at the sa
2. e symbol BRAKE which indicates wind turbine in brake status Wind turbine will stop rotating or running in low speed under brake status Press the Enter key and Esc button at the same time under brake status the symbol BRAKE will disappear and brake status is released In normal situation the wind turbine shall be in running status rather than brake status 4 2 Button Specification LCD backlight will be on after pressing any button The backlight will go out to save power if there is no button operation for 10 seconds fC Up Increase In browsing status press to check the previous parameter In setting window press this button to check the next adjustable parameter or increase the value of current parameter al 1i In Down Decrease In browsing window press v0 to check the next parameter In setting window press this button to check the previous adjustable parameter or decrease the value of current parameter lt Enter Set Contirm In browsing window press Enter to access setting window In setting window press this button to save parameters and return back to browsing window lt Esc Cancel Manual reset In setting window press Esc to return to browsing window without saving the modified parameters 4 3 Parameters Browsing 1 When power is on the LCD is under browsing window and displays battery voltage XX X V 2 In browsing window LCD will circularly display the following parameters by press
3. ing wh button and Y Phaesun GmbH Br hlweg 9 87700 Memmingen Germany Telefon 49 8331 990 42 12 info phaesun com www phaesun com ce Phaesun Stand alone solar solutions button BAT WIND PV WIND AMM VW AM W ARM V KKA W aL A i XX X A Ne ma ye XXX W gt wen WIND XX A 4 Technical Data Product Model HY C10 24AWM HY C10 48AWM 21A 58V LCD 24V Ambient Temperature amp Humidity 20 55 C 35 85 RH Without Condensation Temperature Compensation Function 7 AmV C 2V 35 C 80 C Precision 1 C Optional Package size LxWxH 51x50x25cm Net Weight 10kg Gross Weight 11kg In order to serve our customers better Our company can adjust parameters configuration according to customer s requirement 5 Troubleshooting If your phenomenon is out of following descriptions or should you have any problems about these products please contact Phaesun GmbH Br hlweg 9 87700 Memmingen Germany Telefon 49 8331 990 42 12 info phaesun com www phaesun com ce Phaesun Stand alone solar solutions manufacturer in time Battery is over voltage check battery voltage and whether the cables are The symbol flashing without charge well connected or not re connect all components or discharge H u a Firstly open the software parameter control please check if the setting is BRAKE If yes please cancel it b Secondly Disconnect wind turbi
4. me time specially designed for high end wind solar hybrid system and also suitable for wind solar hybrid power system and wind solar hybrid monitoring system It is used to control the wind generator and solar panel to charge the batteries safely and efficiently With decent appearance easy operation visual LCD display and perfect protection functions the apparatus has high charge efficiency low no load loss The wind solar hybrid controller is the core component of the off grid power generation system The performance of the controller will impact the life and the stability of the whole system especially the lifespan of battery banks 1 Performance Description lt Reliability Intelligentzed modularized design simple mechanism powerful functions With industrial range superior components and strict production technology the controller can be used in relatively bad working environment and has reliable performance and long life span lt PWM Stepless Dump load Mode dump residual power with division into thousands of stages It can dump residual power while charging battery banks which is benefit to effectively extend battery longevity lt Voltage Limiting and Current Limiting Charge Mode When battery voltage exceeds the pre set floating voltage point the Phaesun GmbH Br hlweg 9 87700 Memmingen Germany Telefon 49 8331 990 42 12 info phaesun com www phaesun com cE Phaesun Stand alone solar soluti
5. ne battery with controller successively LCD display BRAKE all the time Reconnect them a few minutes later then check if it comes back to normal 6 Guarantee and Liability One year warranty is available for our product from the date of delivery If the product is out of warranty or damaged by transportation inappropriate operation human factors force majeure no guarantee is made Appendix Appendix l Copper Wire Over current Capacity Wire Diameter mm Over current capability A Wire Diameter mm Over current capability A Phaesun GmbH Br hlweg 9 87700 Memmingen Germany Telefon 49 8331 990 42 12 info phaesun com www phaesun com
6. ong polarity of battery shall be forbidden Please refer to Appendix for copper wire over current capability Step 4 Connect the wind turbine output lines to the WIND INPUT terminals in condition of wind turbine in action less or low speed Step 5 Connect solar panels to the SOLAR INPUT terminals Step 6 Check all connection is proper and firm or not Step 7 If the controller has communication function user can read and set relevant parameters via software Step 8 User can set relevant parameters through LCD buttons Phaesun GmbH Br hlweg 9 87700 Memmingen Germany Telefon 49 8331 990 42 12 info phaesun com www phaesun com CE Phaesun stand alone solar solutions 3 LCD Display Instruction and Key Specification 4 1 LCD Display Instruction FIND PY BEBB aa e oe ee men a i 1 Wind turbine symbol 2 re Day symbol 2 Night symbol 3 E Battery symbol inner strip graph indicates the battery power status Five inner horizontal strips display indicates the battery is full The symbol u shall be flashing when the battery is over discharge flashing will not stop until battery voltage recover The symbol shall be flashing when the battery is over charge flashing will not stop until battery voltage recover 4 88 38 Parameters display symbol Each system parameters are displayed via visual digit and graph 5 Press the Enter key and Esc button at the same time LCD displays th
7. ons controller will adopt PWM voltage limiting charge mode It dumps the excess energy When wind turbine charging current exceeds pre set brake current point the controller will automatically start brake to protect battery banks lt LCD Display Function LCD screen can display system status and parameters via visual digital and graphic form Such as battery voltage wind turbine voltage PV voltage wind turbine current PV current wind turbine power PV power battery power status etc lt Perfect Protection Functions Battery over charge protection Battery over discharge protection Battery anti reserve connection protection wind turbine current limiting charge automatic brake manual brake solar anti reverse charge protection solar anti reverse connection protection lightning protection etc 2 Installation Instruction BATTERY SOLAR INPUT WINDINPUT BEZ EEE BE DES DE IE EI Ar Step 1 Check the package and then check the controller for damage after unpacking Damaged controller cannot be installed in the system Step 2 For controller whose dump load box is separated please connect dump load box to the DUMP LOAD terminals of the controller Step 3 Connect battery positive pole to the positive BATTERY terminal Connect battery negative pole to the negative BATTERY terminal with copper core cable Note Although the controller has anti reverse connection protection function wr
Download Pdf Manuals
Related Search
Related Contents
PSB HD8 Subwoofer Review and Test OS 100 "NOTRE RENTREE !" CTA Digital MI-UBP backpack Microsoft Office Excel 2007 – Level I Instruction manual, model 4000SU FMOspl Sharp EL-1192BL Owner's Manual Writing Simple Spice Netlists CAMH MONITOR METADATA USER'S GUIDE Guía de ayuda de Tablet Copyright © All rights reserved.