        Thermo Scientific Touch Screen Digital Dry Bath User Manual PDF
         Contents
1.     Thermo Scientific    Thermo Scientific    Section 5 Preparation Work    This chapter introduces the structure of the instrument  user interface and  functions of all buttons and preparation before startup  Read the content  in the chapter carefully before startup when using the instrument for the  first time     1  Structure Interface        y        Housing         Front Cover    LCD Touch Screen    Figure 5 1  Unit Front    Se  Outlet for External  CU Temperature Sensor    Product Label       iiu    Handle    Power Socket  Fuse Housing     Power Switch  Figure 5 2  Unit Back    Note 1  When the external temperature sensor is connected  the internal  temperature sensor will disconnect automatically  and the temperature control  and display will relay on the external temperature sensor    2  DO NOT plug in or remove the external temperature sensor without the  power being off     5 1    Section 6 Operation Guidance    The chapter introduces the display window and the operation of buttons  of the dry bath with constant temperature     Examination Before Confirm the following before inserting the plug into the power socket     Sta rt Up 1  Ensure the power source is in accordance with the voltage requirement  of the instrument  refer to Features section for voltage requirements      2  Make sure the plug has been completely inserted into the power  socket     3  Ensure the power line has been reliably grounded     Caution If the display of the instrument is abnormal after s
2.    Thermo Scientific Touch Screen Drybath    Dry Bath with Advanced Microprocessor Control    Catalog Number   88870007  88870008  88870009  88870010  88870011  88870012  Operation Manual 0000849    Visit us online to register your warranty  www thermoscientific com labwarranty    Preface    Safety Information    Alert Signals    Warning The warning message requires extremely careful operation of a certain step  Failure to  observe the instruction may result in serious personal injury     Caution Important information is contained in any item and should be carefully read  Failure to  observe the instruction would result in damage or abnormal function of the instrument     Note Notes alert you to pertinent facts and conditions     Warning If the Thermo Scientific Touch Screen Drybath is used in a manner not specified by the  manufacturer  the protection provided by the unit may be impaired     Thank you for selecting Thermo Scientific for your equipment needs     Your Thermo Scientific Touch Screen Drybath has been designed with functionality  reliability  and  safety in mind  It is your responsibility to use this instrument in conformance with local electrical  codes  It is very important that the user follows installation instructions exactly as written  Do not  attempt operation without this information        All rights reserved  Thermo Fisher Scientific reserves the right to modify this manual at any time  without notice  Without prior written consent from Thermo Fisher S
3.   supplier for service      Liquid drops into the inside of the instrument      The instrument is rained on or water is spilled on it       The instrument works abnormally  especially if generating an abnormal  sound or odor       The instrument is dropped or its casing is damaged       The function of instrument obviously changes   Section 2 Maintenance    The holes of the blocks should be regularly cleaned with the damp cloth to  ensure the test tube be well contacted with the wall of the holes so as to  have good heat conduction  If the surface of the instrument is polluted  it  can be cleaned with a slightly damp soft cloth     Warning When cleaning the instrument  the power supply should be shut  off and unplugged  The instrument surface should be cleaned with a non   corrosive cleaning agent  A    2 1    Thermo Scientific    Section 3 Introduction    Caution After unpacking  immediately check the goods against the  packing list  In case of damaged or missed goods  please immediately  contact the distributor in which the product was purchased from  After  unpacking  the packing box and packing materials should be well kept for  future repair  For the damage of instrument occurring during transporting  to the repair department due to improper package  Thermo Fisher  Scientific will not be held responsible for damages  A    The product is dry bath with advanced microprocessor control  which can  be widely applied to sample reservation  enzyme reservation and reaction   DNA
4.  0 0 cece eee eee eee eee 10 1    Thermo Scientific    Section 1 Safety    During operation  maintenance and repair of this instrument  the  following basic safety notes should be observed  In case of failure to follow  these instructions  the warnings or notes indicated herein  the basic  protection provided by the instrument  its safety criteria of design and  manufacture  and its predicted use range would be impaired  If the  equipment is used in a manner not specified bythe manufacturer  the  protection provided by the equipment may be impaired    Thermo Fisher Scientific is not responsible for any injury as a result of the  user s failure to observe the following requirements     Caution This instrument is for indoor use  A    a  Ihe ground connection    To avoid the electric shock  the input power line must be reliably  grounded  The instrument is equipped with the three pin plug that has the  third pin  the pin connects the ground   therefore  the plug should be used  with the grounded power socket only  This is a kind of safety device  If the  plug cannot be plugged into the power socket  please ask the electrician to  install a correct power socket  so as to make the grounded plug to work for  safety     b  Servicing and Replacement of Parts    The operator should not take apart the instrument without permission   Only qualified professionals are allowed to replace elements or adjust  components inside the instrument  Replacement of components while unit  is connecte
5.  amplification  electrophoresis degeneration and serum coagulation   etc  The characteristics of the product are as follows       The digital display and control of the temperature       Heat blocks help avoid possible contamination while containing the  sample inside a tube      The heat blocks are easily replaced  cleaned or disinfected and are suit   able for various tubes       Built in over temperature protection device warrants sample and user  safety      Temperature deviation adjustment     3 1    Section 4 Features    This chapter introduces the usage  transportation  storage conditions of the  instrument  as well as its basic parameters  performance and functions     1  Normal working conditions  Ambient temperature  10  C 30  C  Relative humidity   lt 80   Power supply  100 120V 50 60Hz or 200 240V  50 60Hz    Altitude  Up to 2000 m Pollution Degree 2  Overvoltage category   II Indoor use    Caution Before using the instrument  make sure the working conditions  meet the above requirements  A    2  Transportation and storage conditions  Ambient temperature   20  C  55  C  Relative humidity   lt 80     3  Basic parameters    Table 1  100 120V    Parameters   Type Touch Screen 1 block   Touch Screen 2 block   Touch Screen 4 block  TH 100 120V 100 120V 100 120V    Temperature Range Ambient Temperature  5  C 130  C  ambient temperature 25  C    Temperature Uniformity  lt  1 0  C    Temperature Accuracy  lt   0 5  C 37  C    Temperature Fluctuation  lt   0 5  C     lt  2
6. 0    Nordic Baltic countries  358 9 329 100  Russia   CIS  7  812  703 42 15  Spain   Portugal  34 93 223 09 18    Switzerland  41 44 454 12 12  UK Ireland  44 870 609 9203    Asia  China  86 21 6865 4588 or  86 10 8419 3588  India toll free 1 800 22 8374  India  91 22 6716 2200    Japan  81 45 453 9220  Other Asian countries  852 2885 4613     Countries Not Listed   49 6184 90 6940 or  33 2 2803 2180 l  hermo    SCIENTIFIC    A Thermo Fisher Scientific Brand    
7. 5 min  Crise from 30  C to 130  C      373x200x100 mm 403x200x100 mm 535x200x100 mm  4 1x7 87x3 94 in 15 9x7 87x3 94 in 21 1x7 87x3 94 in    Temperature Rise Time  lt  20 min Crise from 30  C to 130  C   Size  mm   LxWxH     Weight 3 4 kg  7 5 Ibs   3 7 kg  8 16 Ibs   5 1 kg  11 24 Ibs      Fuse Protector  g5x20  F250V 2 5A F250V 5A F250V 8A       Thermo Scientific 4 1    Section 4  Features    42       3  Basic Parameters  continued     Table 2  220V    Parameters ye Touch Screen 1 block   Touch Screen 2 block   Touch Screen 4 block  YP 200 240V 200 240V 200 240V    Temperature Range Ambient Temperature  5  C 130  C  ambient temperature 25  C      Temperature Uniformity  lt   1 0  C    Temperature Accuracy  lt   0 5  C 37  C    Temperature Fluctuation  lt   0 5  C     lt  25 min  Crise from 30  C to 130  C      373x200x100 mm 403x200x100 mm 535x200x100 mm  14 7x1 87x3 94 in 15 9x7 87x3 94 in 21 1x7 87x3 94 in    Weight 3 4 kg  7 5 Ibs   3 7 kg  8 16 Ibs   5 1 kg  11 24 Ibs    Fuse Protector  g5x20  F250V 2 5A F250V 2 5A F 250V 3 15A    Caution The instrument shall be used from low to high temperature  A    Temperature Rise Time  lt  20 min Crise from 30  C to 130  C     Size  LxWxH     Declaration of Conformity    We hereby declare under our sole responsibility that this product conforms  with the technical requirements of the following standards     CE EMC  EN 61326 1   CE Safety  EN 61010 1   CE Safety  EN61010 2 010   UL  61010 1 CSA C22 2 NO  61010 1  ROHS2 0  2011 65 EU
8. cientific  any part of the manual  should not be duplicated  reproduced or translated into any other languages     MANUAL NUMBER 0000 849          0 12 1 2014 Original  REV ECR ECN DATE DESCRIPTION By    Thermo Scientific i    Preface    Do You Need Information or Assistance on  Thermo Scientific Products     If you do  please contact us 8 00 a m  to 6 00 p m   Eastern Time  at     1 740 373 4763 Direct   1 800 438 4851 Toll Free  U S  and Canada  1 877 213 8051 FAX  http   www thermoscientific com Internet Worldwide Web Home Page  service led marietta thermofisher com Tech Support Email Address  www unitylabservices com Certified Service Web Page    Our Sales Support staff can provide information on pricing and give you quotations  We can  take your order and provide delivery information on major equipment items or make  arrangements to have your local sales representative contact you  Our products are listed on the  Internet and we can be contacted through our Internet home page     Our Service Support staff can supply technical information about proper setup  operation or  troubleshooting of your equipment  We can fill your needs for spare or replacement parts or  provide you with on site service  We can also provide you with a quotation on our Extended  Warranty for your Thermo Scientific products     Whatever Thermo Scientific products you need or use  we will be happy to discuss your    applications  If you are experiencing technical problems  working together  we will 
9. ck whether the connecting wire of  EX Open circuit of sensor  buzzer alarms in a di   di   sound sensor is damaged  and replace it    Power supply fails to be connected   Check power supply and connect it  Fuse burned Replace fuse  Display window is not turned on after  switching on power supply  Damage of the switch Replace the switch  4    1  buzzer alarms in a di   di   sound Use the external sensor without Put the external sensor correctly into the  putting it into the module corresponding place of the module  Temperature display does not conform to ensor is damaged or in poor    5 p p ay  gt  g p Contact supplier or factory  actual temperature contact    Caution The user is not allowed to open the housing of the instrument for  inspection during the warranty period  If any failures result from opening  the housing for inspection  contact Thermo Fisher Scientific  A    Sensor is damaged or the heat 1  blocker is damaged Contact supplier or factory  The LCD shows    Err code  0x3  and the       Thermo Scientific 74    Section 8    Modular Block Accessories    8 1    Modular Block Accessories     Wumsmax  CS  ECT          For 25mm test tubes  For 0 5ml test tubes    For 96 well Elisa plate    For mixed size test tubes   32 holes for 6mm test tubes  21 holes for 10mm test tubes    For mixed size test tubes   18 holes for 1 5ml test tubes  10 holes for 2 0ml test tubes    For mixed size test tubes   3 holes for 25mm test tubes  12 holes for 13mm test tubes  6 holes for 6mm te
10. d to power and or turned on is prohibited     c  Observe voltage power requirements    Before the instrument is connected with the AC power source  the voltage  of the power source should be the same with the required voltage of the  instrument  a deviation of 10  is allowed   The rated load of the power  socket should not be lower than the requirements of the instrument     d  Ihe power cord    The instrument should use the power line cord attached to it  If the  power line is destroyed  it must be replaced but not be repaired  The  replacement should be carried out with the power line of the same type  and same specification  No items should be put on the power cord when  the instrument is in operation     Section 1  Safety    e  Connecting and disconnecting from to power source    The user should hold the plug to remove from power source  When  connecting the plug  user should make sure it has been fully plugged in   when removing the plug  do not pull the power line forcefully     f  Placement of the instrument    This instrument should be fixed in a low RH and low dust place away  from water source  e g  sink or water pipeline  and the room should be  well ventilated  and free of corrosive gas or interference of strong magnetic  field   The instrument should not be placed in a wet or dusty location     The openings on this instrument are for ventilation circulation and in  order to avoid over heat of the instrument body they should not be  blocked or covered  When a sing
11. e first two  2  years  component parts proven to be non conforming in materials or workmanship will be repaired or replaced at Thermo s  expense  labor included  Installation and calibration are not covered by this warranty agreement  The Technical Services Department must be contact   ed for warranty determination and direction prior to performance of any repairs  Expendable items  glass  filters and gaskets are excluded from this  warranty     Replacement or repair of components parts or equipment under this warranty shall not extend the warranty to either the equipment or to the compo   nent part beyond the original warranty period  The Technical Services Department must give prior approval for return of any components or equipment   At Thermo s option  all non conforming parts must be returned to Thermo Fisher Scientific postage paid and replacement parts are shipped FOB desti   nation     THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES  WHETHER WRITTEN  ORAL OR IMPLIED  NO WARRANTIES  OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY  Thermo shall not be liable for any indirect or consequential  damages including  without limitation  damages relating to lost profits or loss of products     Your local Thermo Sales Office is ready to help with comprehensive site preparation information before your equipment arrives  Printed instruction man   uals carefully detail equipment installation  operation and preventive maintenance     If equipment s
12. ervice is required  please call your Technical Services Department at 1 800 438 4851  USA and Canada  or 1 740 373 4763  We re ready  to answer your questions on equipment warranty  operation  maintenance  service and special application  Outside the USA  contact your local dis   tributor for warranty information     Rev  0 9 13                Warranty Scope    The above mentioned warranty does not apply to damages incurred by improper use and maintenance  using  under unqualified conditions  unauthorized maintenance or modification     Thermo Fisher Scientific does not provide any other warranty expressions otherwise  and does not bear liabilities for  business promotion under special circumstances     Thermo Scientific 10 1    thermoscientific com       2014 Thermo Fisher Scientific Inc  All rights reserved  All trademarks are the property of Thermo Fisher Scientific and its  subsidiaries  Specifications  terms and pricing are subject to change  Not all products are available in all countries  Please consult your  local sales representative for details     For the name of the authorized Thermo Scientific product dealer nearest you or any additional information  contact us    North America  USA   Canada   1 866 984 3766  866 9 Thermo   www thermo com   Europe  Austria  43 1 801 40 0  Belgium  32 2 482 30 30  France  33 2 2803 2180  Germany national toll free 08001 536 376   Germany international  49 6184 90 6940  Italy  39 02 02 95059  434 254 375  Netherlands  31 76 571 444
13. help you  locate the problem and  chances are  correct it yourself   over the telephone without a service  call     When more extensive service is necessary  we will assist you with direct factory trained  technicians or a qualified service organization for on the spot repair  If your service need is  covered by the warranty  we will arrange for the unit to be repaired at our expense and to your  satisfaction     Regardless of your needs  our professional telephone technicians are available to assist you  Monday through Friday from 8 00 a m  to 6 00 p m  Eastern Time  Please contact us by    telephone or fax     International customers  please contact your local Thermo Scientific distributor        ii Thermo Scientific    Thermo Scientific    Section 1    Section 2    Section 3    Section 4    Section 5    Section 6    Section 7    Section 8    Section 9    Section 10    Table of Contents    HII we 1 1  Maintenance cuoc x K K AERIS Oe ER irt eem se ta eee 2 1  urpis 3 1  Fealures eC CE 4 1  Preparation Work        xx x K x x K K K K K x K K K cece eee eee eeeeeees 5 1  Operation Guidance                  ccc eee eee nennen nennen 6 1  Examination Before Start Up      a a ee 6 1  viri dd PEN 6 1  Operation Instructions en se ae EE Rx e RENS 6 1  Failure Analysis and Troubleshooting                            7 1  Modular Block Accessories         e exe e x e x x K x K nenn nenn 8 1  Wiring Diagrama    2 42 socer ami de wea e rk CR ros 9 1  Warranty Information                 
14. into  the program running     S  interface  If the alteration of the program has not been saved yet  the  warning box will pop up     File not saved data will    be lost continue     EM NM    Press    YES     and the program will run in the changed form  but the  changes won t be saved  Press    NO    to go back to the program setting  interface     The user can set 1 5 sections of the program  Press to delete the    corresponding section  when there is only one section  this step would  be of no use            Press E to add sections  Choose the corresponding box to set the    corresponding temperature and time   Caution This instrument doesn t have cooling function  If the user wants    to set multiple sections  set the temperature from low to high  Otherwise   the temperature will be very slowly decreasing while the blocks cool down     Thermo Scientific 6 3    Section 6  Operation Guidance    Operation Instructions Files saving interface   continued  Press  BACK  to go back to the program setting interface   Press  SAVE  to save the file     Press    RUN    to enter into the program running interface  If the  changed program has not been saved  the warning box will pop up        Choose  File name  and            Password    to set the file            name and the password  By Sem E    pressing Figures from 2 9  quickly  the input method T   will be changed to English to BED    set the file name     Program running interface    Press    CAL     to call for the    temperatu
15. ld be no    CAL       and the temperature is unable to be adjusted         Input the correct temperature into the box that pops out     Caution a  To ensure the accuracy of temperature  the instrument should  be calibrated after temperature stabilizes for 30 minutes     b  Calibrate the instrument with the qualified Grade II standard filled    thermometer    c  Calibration point  The middle hole of the heat block  Pour paraffin  oil into the well  and soak the thermometer bulb     Instruction  During the operation of the instrument  the temperature and  the time should not be changed  If it they should  stop the program and  enter into the setting interface to change them     Listed files interface    Press    BACK    to go back to the main interface           Enter into the setting  interface of the specific file in  accordance with its name  If  the file has a password  then  enter into the password  inputting interface        Thermo Scientific    Section 6  Operation Guidance    Operation Instructions Password imputing interface   continued  Input the password into the box           Caution  If the password has been forgotten  user  can use 000000 to ROOT and then the file will  be reset to the initial state  the name of the file  would not be changed      Program setting interface    Press    BACK    to go back to  the listed files interface EUN        KC     1080 X 00 01 hhmm     Press    SAVE    to enter into    the files saving interface       Press    RUN    to enter 
16. le set of instrument is used  the interval  between ventilation opening before and after the instrument and its nearest  object should not be less than 25cm  Also  don t use the instrument on  loose or soft surface  or the air inlet of instrument bottom might be  blocked  Excessive temperature will impair performance or result in failure  of instrument  This instrument should not be used in location subjected to  direct sun light  The instrument should be kept away from hot gas  oven  and all other heat sources  If the instrument is to be stored for a long time   the power plug should be withdrawn and the instrument covered with soft  cloth or plastic film to avoid entrance of dust    The product is powered by connecting the mains plug to a standard  socket outlet Always place the product in such a way that it is easy for the  operator to disconnect the product from the mains supply     Thermo Scientific    Thermo Scientific    g  Explanation of symbols  Attention  read user manual before use     Warning  There is a sign of  CAUTION  HOT SURFACE   ATTENTION  SURFACE HOT  on the instrument  The metal part     module  near the sign should not be touched with any part of the body  when the instrument is operating in a high temperature state or just    finished operation to avoid burns  A    Alternating Current  Protective Conductor Terminal    Caution In any of the following cases  immediately turn off the power  supply  withdraw the power plug from the power socket  contact the
17. re adjustment EN 21314  interface    If the external TEMP  EE  105 0  037 0      sensor is being used  then QIME tnn ETRE 00 01   00 01   there would be no    CAL        and the temperature is unable        038 1 01 00 00 hh mm ss     Total time 00 00 18 hh mm   to be adjusted   Refer to  ser  PAUSE J OP        Single Running Interface               Press    SKIP    to skip to the next section  If it is the last section  the  interface of asking you whether to stop the program will appear  Refer  to    Single Running Interface        Press    PAUSE     the program will be paused and the temperature will  be maintained to the set temperature and the pause interface will pop  up    SS      Program is Paused     Press    STOP     the cancel interface will pop up  Refer to    Single  Running Interface        Instruction  During the operation of the instrument  the temperature and  the time should not be changed  If needed  stop the program and enter  into the setting interface to change them     6 4 Thermo Scientific    Section 7 Failure Analysis and  Troubleshooting    This chapter details possible failures of this instrument and possible causes  with troubleshooting     Failure Analysis and Troubleshooting    Contact Thermo Fisher Scientific    The LCD shows  Err code  0x1    and the DM Check whether the connecting wire of  uon Short circuit of sensor      buzzer alarms in a di   di   sound sensor is damaged  and replace it    3    The LCD shows    Err code  0x2  and the oe Che
18. st tubes    For mixed size test tubes   30 holes for 0 5ml test tubes  20 holes for 0 2ml test tubes    For 15 ml flat bottom test tubes   For 50 ml flat bottom test tubes   For 15ml conical bottom test tubes   For 50ml conical bottom test tubes   For 96 well none skirted PCR plate   For 96 well half   full skirted PCR plate  Temperature Probe  PT1000    32421    40  3     8  5  5    1  1  1  4  1  4  1  1    888701  888701  888701  888701  888701  888701  888701    0  01    2  3  4    6  7  8    88870109  88870110  88870111       88870112  M    uli  30   20 88870115             Thermo Scientific     zum       gen    979 919       RIE  U                                                 ES  N  N  S   amp  briw ezar LON  3 X gen va EHR  ES x oe Ey Hex ven sen  ES QN  X  ren  3 NO   carr  So XL tet  E Ku rr en  Ir     8  m CL37INI  S ges  3 Kr  d rest    NO ar elt  y OXL  N OL   zear NA   S XOL ve csb65s6b6bs BI Xn WL  eg E Ux  S VEADSCOV  S   88 5  0L rHAINCECIH  DE ven 7 919939  a  ZHOLIMS  eu  BT    y  e  aA v  EE  D y  ZR  DM WH    9 1    Thermo Scientific    Section 10  Warranty Information       THERMO FISHER SCIENTIFIC STANDARD PRODUCT WARRANTY    The Warranty Period starts two weeks from the date your equipment is shipped from our facility  This allows for shipping time so the warranty will go  into effect at approximately the same time your equipment is delivered  The warranty protection extends to any subsequent owner during the first year  warranty period     During th
19. tartup  turn off  the power source immediately and contact Thermo Fisher Scientific  A    Sta rt Up Press the power switch and the instrument will be powered on  The LCD    screen of the operation panel will show the main interface     Operation Instructions The main interface    Press    Single point set    to  enter into the single setting  interface     Single setting interface             Press  BACK  to go back to  the main interface     wo    BEE    Press    RUN    to enter into me         pgg      the singl i interface   e iie e S  interface Ex 718  9   Press    Temp    to set the una OOO pim  eo   o  clr        temperature  Back  Casa    Press    Time    to set the time     Instruction  There is limitation for temperature and time setting  The  setting temperature range is  15  135  C  the time range is  099  59  and    oo        Thermo Scientific 6 1    Section 6  Operation Guidance    6 2    Operation Instructions   continued     Single running interface       Press    STOP     and the  interface of asking you  whether to stop the program  will appear        100 0 x 10 00 inm      En          nun 039 2 x 10 00 00 hh mm ss     Total time 00 00 15 hh mm                       Stop program      lt   NM    Press    YES    to stop the program and to go  back to the main interface           Press    NO    to go back to the single running  interface     Press    CAL    to calibrate the temperature  adjustment interface   If the external sensor is  being used  then there wou
    