1. 1 On the top of the device locate and remove the dome screw which has a ground symbol beside it 2 Attach the ground wire to the screw hole with the dome screw Wiring the Power Inputs Please follow the steps below to wire power lines from the terminal block to the com pliant external DC power source 1 Before wiring make sure the power source is disconnected 2 Using the wire stripping tool strip a short piece of insulation from the output wires of the DC power source 3 Identify the positive and negative feed positions for the terminal block connec tion See the symbols printed on the panel indicating the polarities and DC input power range in voltage Plugs for Power 1 amp Power 2 4 Insert the exposed wires into the terminal block plugs Only wires with insulation should extend from the terminal block plugs Note that the polarities between the wires and the terminal block plugs must be positive to positive and negative to negative 5 Use a slotted screwdriver to tighten the captive screws EKI 2701HPI AE User Manual 6 2 5 Caution Use Copper Conductors Only 60 75 C tightening to 5 Ib in The wire gauge for the terminal block should be in the range between 12 A 24 AWG RJ 45 Pin Assignments The UTP STP ports will automatically sense for Fast Ethernet 10Base T 100Base TX or Gigabit Ethernet 10Base T 100Base TX 1000Base T connection Auto MDI MDIX means that the port can connect to anot
2. assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers never need to use our repair service If an Advantech product is defec tive it will be repaired or replaced at no charge during the warranty period For out of warranty repairs you will be billed according to the cost of replacement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered For example CPU speed Advantech products used other hardware and software used etc Note anything abnormal and list any onscreen messages you get when the problem OCCUIS 2 Call your dealer and describe the problem Please have your manual product and any helpful information readily available 3 f your product is diagnosed as defective obtain an RMA return merchandize authorization number from your dealer This allows us to process your return more quickly 4 Carefully pack the defective product a fully completed Repair and Replacement Order Card and a photocopy proof of purchase date such as your sales receipt in a shippable container A product returned without proof of the purchase date is not eligible for warranty service 5 Write the RMA number visibly on the outside of the package and ship it prepaid to
3. ee 2 Features en inner 2 Sp CifICAONS 3 55 nr a Idi ecco stadi vasi pee ves dina pedes eit nes idein 3 PACKING IS 4 Dimensions innen ia nn 4 Figure 1 1 Dimensions 4 Hardware Description 5 isudi ulteED 6 TOD VIEW mindre kernel 6 Grounding the POE Injector nenn 6 Wiring the Power Inputs toast tetro fautes 6 RJ 45 Pin Assignments ne saugen 7 Installation 9 DINsRallMouritlrig aria or ttc riaprire 10 3 1 1 Assembling the DIN Rail Clip nennen 10 3 1 2 Hanging the PoE Injector kaniinia 10 Wall Mount Plate Mounting mnn 11 Troubleshooting 13 Troubleshooting aina ane 22a 14 V EKI 2701HPI AE User Manual EKI 2701HPI AE User Manual vi Chapter 1 Overview 1 1 Introduction The Industrial Power over Ethernet Injector provides data and DC power through the Ethernet cable to PoE equipped devices such as IP camera access point PoE split ter or other equipment supporting IEEE 802 3at The injector is typically installed near the Ethernet switch The figure below presents the example for the Power over Ethernet Injector application 1 2 Features 10 100 1000BaseT Power over Ethernet Injector IEEE802 3at compliant Provides power feeding up to 30 watts O
4. H x 95 mm D Li _ fi cal i oi a 3 Cocoon co A esu AT MR Di a Le M Figure 1 1 Dimensions EKI 2701HPI AE User Manual 4 Chapter 2 Hardware Description 2 1 2 2 2 3 2 4 Front Panel On the front panel the Power over Ethernet Injector is equipped with two RJ 45 ports and three LED indicators W LAN port It is an ordinary RJ 45 Ethernet port for data transmitting and receiv ing M PoE port It is an RJ 45 Ethernet port capable of supplying power over the Ethernet cable as well as forwarding data to powered devices E P1 amp P2 The indicators light up when their respective power inputs are active M PoE This LED indicator lights up while power feeding works normally Top View Designed with two power inputs the PoE Injector allows users to supply redundant power rating in the range of 24 to 48V Grounding the PoE Injector Follow the instructions below to attach the PoE Injector to ground Caution When installing the PoE Injector the ground connection must always be made first and disconnected last
5. Mounting Follow the steps below to mount the device with the wall mount plates To remove the DIN Rail clip from the device unscrew the screws that secure it Align the screw holes of the wall mount plates with the ones of the device Use the screws included to secure the wall mount plates on the device Use the hook holes of the wall mount plates to hang the device on the wall To remove the wall mount plates reverse the steps above posco PO EKI 230x 158 00 11 EKI 2701HPI AE User Manual EKI 2701HPI AE User Manual 12 Chapter 4 Troubleshooting 4 1 Troubleshooting Verify that you are using the right power cord adapter Please don t use a power adapter with DC outputs higher than the power rating of this equipment or it will be damaged Select the proper UTP STP cable for your network Please check that you are using the right cable Use unshielded twisted pair UTP or shielded twisted pair STP cable for the RJ 45 connections 1000 Category 3 4 or 5 cable for 10Mbps connections or 1000 Category 5 cable for 100Mbps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators The device can be easily monitored through LED indicators which describe common problems the user may encounter and where the user can find possible solutions If the power indicator does not light up when the power cord is plugged in you may have a pro
6. User Manual EKI 2701HPI AE Industrial IEEE 802 3at Gigabit PoE Injector AD ANTECH Enabling an Intelligent Planet Copyright The documentation and the software included with this product are copyrighted 2012 by Advantech Co Ltd All rights are reserved Advantech Co Ltd reserves the right to make improvements in the products described in this manual at any time without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable How ever Advantech Co Ltd assumes no responsibility for its use nor for any infringe ments of the rights of third parties which may result from its use Acknowledgements Intel and Pentium are trademarks of Intel Corporation Microsoft Windows and MS DOS are registered trademarks of Microsoft Corp All other product names or trademarks are properties of their respective owners Product Warranty 5 years Advantech warrants to you the original purchaser that each of its products will be free from defects in materials and workmanship for five years from the date of pur chase This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel authorized by Advantech or which have been subject to misuse abuse accident or improper installation Advantech
7. blem with power cord Then check for loose power connections power losses or surges at the power outlet If you still cannot resolve the prob lem contact your local dealer for assistance If the cables are properly connected and the LED indicators show normal but the packets still cannot transmit please check your system s Ethernet devices configuration or status EKI 2701HPI AE User Manual 14 15 EKI 2701HPI AE User Manual AD ANTECH Enabling an Intelligent Planet www advantech com Please verify specifications before quoting This guide is intended for reference purposes only All product specifications are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of the publisher All brand and product names are trademarks or registered trademarks of their respective companies O Advantech Co Ltd 2012
8. e 10 100 1000Base T cable schema Switch Router or PC 1 BI DA 1 BI_DB 2 BI DA 281 DB 3 BI DB 3 BI_DA 6 BI DB 6 BI DA 4 BI DC 4 BI DD 5 BL DC 5BI_DD 7 Bl DD 7 BI DC 8 Bl DD 3838 DC Straight Through Cable Schema Switch Switch 1 BI DA 1 BI DA 2 BI DA 2 BI DA 3 BI_DB 3 BI_DB 6 BI DB 6 BI DB 4 BI DC 4 BI DC 5 BI DC 5 BI DC 7 BI DD 7 BI DD 8 BI DD 8 BI DD Crossover Cable Schema EKI 2701HPI AE User Manual 8 Chapter 3 Installation 3 1 DIN Rail Mounting 3 1 1 Assembling the DIN Rail Clip The DIN rail clip is screwed on the device in the factory If not please refer to the fol lowing steps and figure to secure the DIN rail clip on the device 1 Use the screws to secure the DIN rail clip at the rear of the device 2 To remove the DIN rail clip reverse step 1 3 1 2 Hanging the PoE Injector Follow the steps below to hang the device on the standard DIN rail 1 First position the rear side of the unit directly in front of the DIN rail Make sure the top of the clip hooks over the top of the DIN rail M EKI 2701HPI AE User Manual 10 3 2 2 Push the unit downward 3 Check the DIN Rail clip is tightly fixed on the DIN rail 4 To remove the device from the track reverse the steps above Wall Mount Plate
9. her switch or workstation without changing straight through or crossover cabling See the figures below for straight through and crossover cable schema m 10 100Base TX Pinouts Pin Number Assignment 1 Tx 2 Tx 3 Rx 6 Rx Note and signs represent the polarity of the wires that make up each E wire pair The table below shows the 10Base T 100Base TX MDI and MDI X port pinouts Pin Number MDI X Signal Name MDI Signal Name 1 Receive Data plus RD Transmit Data plus TD 2 Receive Data minus RD Transmit Data minus TD 3 Transmit Data plus TD Receive Data plus RD 6 Transmit Data minus TD Receive Data minus RD m 10 100Base TX Cable Schema Switch Router or PC 3 TD gt 53 RD 6 TD 6 RD RD 1 TD 2 RD 2 TD Straight Through Cable Schema Switch Switch 3 TD TD 6 TD 6 TD RD RD 2 RD 2 RD Crossover Cable Schema 7 EKI 2701HPI AE User Manual m 10 100 1000Base T Pinouts The table below describes the gigabit Ethernet RJ 45 pinouts Pin Signal name Description 1 BI DA Bi directional pair A 2 BI DA Bi directional pair A 3 BI DB Bi directional pair B 4 BI DC Bi directional pair C 5 BI DC Bi directional pair C 6 BI DB Bi directional pair B 7 BI DD Bi directional pair D 8 BI DD Bi directional pair D m 10 100 1000Base T Cable Schema The following two figures illustrate th
10. ntech Customer Services Each and every Advantech product is built to the most exacting specifications to ensure reliable performance in the unusual and demanding conditions typical of industrial environments Whether your new Advantech equipment is destined for the laboratory or the factory floor you can be assured that your product will provide the reliability and ease of operation for which the name Advantech has come to be known Your satisfaction is our number one concern Here is a guide to Advantech s cus tomer services To ensure you get the full benefit of our services please follow the instructions below carefully Technical Support and Assistance 1 Visit the Advantech web site at http support advantech com where you can find the latest information about the product 2 Contact your distributor sales representative or Advantech s customer service center for technical support if you need additional assistance Please have the following information ready before you call Product name and serial number Description of your peripheral attachments Description of your software operating system version application software etc A complete description of the problem The exact wording of any error messages EKI 2701HPI AE User Manual iv Contents Chapter Chapter Chapter Chapter 1 dda da di ARON 3 1 3 2 4 4 1 Overview ee eren nennen I Introduction een a p Pee eden re RR
11. verload current protection DC power input ranging from 24 48 V Wide operating temperature 40 75 C EKI 2701HPI AE User Manual 2 1 3 Specifications IEEE802 3 10BASE T IEEE802 3u 100BASE TX Standard IEEE802 3ab 1000Base T IEEE802 3af at Power over Ethernet LAN port Data Signal pins 1 2 3 6 Connector PoE port Data Signal pins 1 2 3 6 Power pins 1 2 V 3 6 V Network Cable 10BASE T 2 pair UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100 m 100BASE TX 2 pair UTP STP Cat 5 cable Cat 5e recom mended EIA TIA 568 100 ohm 100 m 1000Base T 4 pair UTP STP Cat 5e or above cable EIA TIA 568 100 ohm 100 m Power x2 PED PoE x 1 Power Input 24 48Vpc Power Consumption 33 36 watts 24 Voc Operating Temperature Storage Temperature 40 C 75 C 40 F 167 F 40 C 85 C 40 F 185 F Operating Storage Humidity 5 95 Humidity non condensing Dimensions 36 mm x 140 mm x 95 mm W x H x D EMC m CE FCC Class A m EN61000 6 4 m EN61000 6 2 m EN61000 4 2 ESD m EN61000 4 3 RS m EN61000 4 4 EFT m EN61000 4 5 Surge m EN61000 4 6 CS m EN61000 4 8 Magnetic Field Safety UL508 3 EKI 2701HPI AE User Manual 1 4 Packing List B 1x Power over Ethernet Injector 1x Wall mounting kit 1x User Manual CD ROM 1 5 Dimensions The Power over Ethernet Injector dimensions are 36 mm W x 140 mm
12. your dealer Edition 1 Printed in Taiwan November 2012 EKI 2701HPI AE User Manual ii Declaration of Conformity CE This product has passed the CE test for environmental specifications when shielded cables are used for external wiring We recommend the use of shielded cables This kind of cable is available from Advantech Please contact your local supplier for ordering information CE This product has passed the CE test for environmental specifications Test conditions for passing included the equipment being operated within an industrial enclosure In order to protect the product from being damaged by ESD Electrostatic Discharge and EMI leakage we strongly recommend the use of CE compliant industrial enclo sure products FCC Class A Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Opera tion of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense iii EKI 2701HPI AE User Manual Adva