Home

ADAM-4542+ - Advantech

image

Contents

1. automatically The default setting of ADAM 4542 is in Primary By setting the DIP4 of SW3 the ADAM 4542 can be set as Ring or Normal mode We will introduce more about ring operation in the later chapter Default setting Secondary ON Default setting Operation Mode Ring Mode ON Startup Manual 2 Ring Operation Several ADAM 4542 modules can be cascaded to form a ring connection With a circumstance that users plan to use a HMI SCADA to connect multiple kinds of IO device with ADAM 4542 users can apply ring architecture to save lots of cost caused from the number of modules and the length of optical fiber Following diagrams demonstrates the Ring application Ring Operation mode is set by DIP4 of SW3 Limitation While applying ring operation please notice the following limitations It only supports the half duplex Up to 100 ADAM 4542 can be connected over a distance of 1 500 km Redundant mode cannot be used with ring mode Under ring operation RS 232 422 485 all need to set SW2 for baud rate Normal Operation ADAM 4542 Optical ADAMAS42 F Fiber Fi i 3 HJ ADAM S20 Startup Manual 3 Ring Operation Optical Fiber ie fe be g o a A ee i F lt T lt oi Ei f i T T RS 232 RS 422 RS 485 PLC ADAM PC 4000 Note if no device is connected at the RS 232 end under ring operation the communication of the system will be affected
2. or fail LED Description On the face plate of module there are two sets of LED which are status LED and TX RX LED The meaning for LED display method is described as following table Description Status TXRX Tansmittingoaa yow f f ReoevingData fof Power Fiber state Fiber Rx Redundant Working onf _Power Fiber state Fiber Rx Redundant Failed on Startup Manual 4 Wiring Diagrams Non Redundant System A ADAM 4542 Single Mode Fiber Optic to 2 F Fiber RS 485 j oyondo eqs epow ibus bSb INWaV f AMOAUOD SBb Zeb 2E2 SH RS 232 422 485 Converter 7 a a Primary T Ga ie aaa We Fiber oo a Redundant Interlock i ee ea e RS 485 RS 485 ii Fiber hii Secondary Secondary Ov 24vde 24vdc Ov Redundant systems can also support RS 422 In a redundant system the ground of the external power for modules must be connected together Startup Manual 5 Ring Operation System ADAM 4542 ADAM 4542 Single Mode Fiter Optc to rene tne Sirge Mode F Ber Optex to Sirge Mode f Der Optex to RS 485 RS 485 RS 485 RS 485 Pin Assignment of Cable 1700090253 DB 9 to 3 Wires Cable DB 9 Connector 3 Wires Connection White Red Black Troubleshooting Proben O Go o y OO The TX and RX connections are reversed Make sure the fibe
3. ADAM 4542 Fiber Optic to RS 232 422 485 Converter Overview Fiber optic transmission offers the benefits of wide bandwidth immunity to EMI RFI interface and secure data transmission The ADAM 4542 can be used as an RS 232 422 485 point to point or point to multipoint connection for transmitting and converting full half duplex signals and their equivalents within a fiber optic environment Fiber optics are the perfect solution for applications where the transmission medium must be protected from electrical exposure lighting atmospheric conditions or chemical corrosion The ADAM 4542 is specially designed to link various machinery equipped with RS 232 422 485 communication ports such as computer systems or manufacturing machines Using standard SC connectors the module s fiber optic port can accommodate a wide range of fiber optic cable ADAM 4542 also supports the redundancy requirement You can use two pairs of ADAM 4542 for a redundant architecture This special design offers higher reliability Packing List Before you begin installing your module please make sure that the following materials have been shipped 1 x ADAM 4542 Module with DIN rail mounting bracket 1 x ADAM 4542 User Manual 1 x Panel Mounting Bracket 1 x Cable for DB 9 to 3 wired If any of these items are missing damaged contact your distributor or sales representative immediately For more information on this and other Advantech product
4. data bits The option of changing to 9 11 or 12 bits is for use with other modules other than ADAM modules that have different data formats Should you change the ADAM module s data format be aware that you will also have to change the data format on all the other modules in the network SW2 Switch 2 sets the baud rate for RS 485 auto flow control The options range from 1200 bps to 921 62 kbps The factory default is 9600 bps Be aware that when you change the baud rate you also have to change the baud rate for all of the connected modules accordingly You can refer to the table below to make sure when you need to set SW2 Baud Rate ee pp LE EEEE eons o o o or e e or moons or o or Lo or one fo O or or Bo LO oe aie J oo or anan for or aM or or om srs for for or aM or msza for or or for or aL ese om or or or Jom Or eee o or or or or or om o seo fo fo or or or or om om ace Jor or or or or oJ Default setting sae O UOS Teranon mone ase asa roas oma o fo fe Pring ves e e SW3 The ADAM 4542 can support redundancy and ring operation By setting the DIP3 of SW3 the ADAM 4542 can be set as Primary or Secondary mode in the redundant architecture The Primary connection is the major connection line If any of the ADAM 4542 modules on the Primary line fails the Secondary line will take over the connection
5. ondensing Accessories DIN rail mounting adapter panel mounting bracket Two Year Warranty Advantech warrants to you the original purchaser that this product will be free from defects in materials and workmanship for two years from the date of purchase This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel authorized by Advantech or which have been subject to misuse abuse accident or improper installation Advantech assumes no liability under the terms of this warranty as a consequence of such events If your product is defective it will be repaired or replaced at no charge during the warranty period package and ship it prepaid to your dealer ke Am md ce U a a C a rm TEN Switch and Jumper Settings ADAM 4542 provides three DIP switches that users can configure the settings for their applications SW1 and SW2 set the data format and baud rate of serial communication SW3 sets the Primary Secondary mode for the redundant application SWI Switch 1 controls the data format Data can be 9 10 11 or 12 bits The factory default is 10 bits one start bit eight data bits one stop bit and no parity bit Data Format iovts on Li2oits fono Default setting When using the converter in combination with other ADAM modules do not change the default setting of the converter since ADAM modules have a fixed data format often
6. r connection is made so that the TX of one end is connected to the RX of the other Poor connection between the ADAM 4542 and the Make sure the ADAM 4542 is securely plugged into communication port in computer the communication port Attenuation on the fiber causes the signal level to drop Reduce attenuation by reducing connector loss below the accepted level transmission distances etc The connection between the communication ports is Add a converter to one of the optical modems so that neither DTE to DTE nor DCE to DCE connection the pin assignments from the communication port to the modem are from pin 2 to pin3 and from pin 3 to pin 2 Damage Test If none of the above resolved your problem your module may be damaged To test for damage use the hyper terminal program of MS Windows to perform a loop back test of the optical modem This will detect if the module is damaged Startup Manual 6
7. s please visit our websites at http www advantech com http www advantech com eAutomation For technical support and service http www advantech com tw eservice This startup manual is for the ADAM 4542 Part No 2004542002 Ath Edition October 2013 1 Startup Manual Direct plug and play Easily mounted on a DIN rail panel or piggybacked Transmission speeds of up to 921 6 kbps RS422 485 Optical fibers enable transmission of up to 15 km Half Full duplex bidirectional transmission mode Support for ring mode Avoid lightning strikes and EMI RFI Prevents damage from electrostatic discharge Stable and error free data transmission Automatic internal RS 485 bus supervision No external flow control signals required for RS 485 Transient suppression and over current protection on RS 232 422 485 data lines LED for power and data flow indication Specifications Fiber Optic Single Mode Wavelength 1310 nm Transmission Distance 15 km Optical Power Budget attenuation 15 8 dBm Casing ABS with captive mounting hardware Communication Mode Asynchronous Connector Plug in screw terminal Fiber port SC Transmission Mode Full Half duplex bidirectional Transmission Rate Up to 921 6 kbps Power Requirement Unregulated 10 30 Voc Operating Temperature 10 70 C 14 158 F Operating Humidity 5 95 non c