Home
        Lady-Comp: The “Intelligent” Cycle Computer.
         Contents
1.  M    day     Lady Comp Fertility Monitor User Manual    Lady Comp BBT  Basal Body Temperature  Reading Basics   Taking your basal body temperature regularly each day is one of the key elements of the Lady Comp system  The basal body  temperature is the temperature immediately after waking up  before talking  drinking  or becoming active in anyway  While taking  your temperature  avoid moving the thermal sensor  Best results are achieved by choosing the same sensor position each day     Reading Time Window and Time Limit    e  Lady Comp controls the temperature reading time limit  The window of time within a temperature reading must be  taken is set in one of two ways  1  The alarm  or 2  The previous days temperature reading time  which will establish  the default temperature reading time for the following day    e The time frame in which a temperature reading can be taken is comprised of a 6 hour period beginning and ending 3  hours before  and 3 hours after the actual temperature reading time  if differing from the alarm setting time     Temperature time limit example    1st day Actual temp reading at 6 00am   27d day Temperature reading time limit   3 00am to 9 00am   Actual reading performed at 7 00am   34 day Temperature reading time limit   4 00am to 10 00am   Actual reading performed at 9 00am   4th day Temperature reading time limit 6 00am to 12 00pm    Temperature Reading Essentials    e Temperature can be taken once a day  within the temperature reading time limit 
2.  The alarm must be activated before  the first temperature reading    e The thermometer symbol remains illuminated throughout the temperature reading time    e    Lady Comp will beep upon completing your temperature reading    e Unless you are confirming or negating the    M    light indicating menstruation  no further steps are taken after completing  a temperature reading    e If there is no temperature reading for one day  the temperature reading time limit is left open and must be set again by  activating the alarm before 12 PM the day before the next reading  Usually the alarm time and temperature reading  default time are the same    e  f you wake within the temperature reading time limit  for example  to care for a child  take your temperature  If you get  up late and the temperature reading time limit is over  there is no temperature reading for that day       We recommend using the Lady Comp alarm to wake you up each day     Taking Your Temperature  1  Lady Comp wakes you with an acoustical signal  Press any button to turn off the alarm tone   2  The thermometer symbol is illuminated  It is ready for a temperature reading   3  Place the thermal sensor under your tongue  near the back  to the right or left of the frenulum and close your mouth   4  Press any button to begin the temperature reading  The thermometer symbol flashes and the temperature reading  takes less than 60 seconds        The display shows temperature reading values from 94 1 99 99   Fahrenheit   34 
3.  displays   i e  C 10   3  Press the minus button once  The average length of your cycles will display   i e  L 28   4  Press the plus button twice  The average increase in temperature after ovulation will display   i e   49   F increase in  temperature   Press the plus button again  The average fluctuation in ovulation day is displayed in plus minus days   6  Press the plus and minus buttons simultaneously to return to the current time display     on    12 Lady Comp Fertility Monitor User Manual    Further Important Lady Comp Operating Information    Returning to Use After an Interruption  The date  the year and the time continue to work automatically without connection to power supply or battery     If no temperatures are taken  the temperature reading time limit is left open and must be reset by setting the alarm for the next  morning  For the period where no temperature readings were taken  you may enter previous    M    data  provided there are no  temperature readings taken in between     Shift Work  In case of shift work the alarm setting and temperature reading time limit is set for the real sleep time  The basal body    temperature is always taken after several hours of sleep   Ideally 5 hours of sleep  three hours of which should be consecutive      Rechargeable Battery  It is recommended to re charge the Lady Comp regularly and at least every 3 months if placed in storage  to maintain battery  function     Summer and Winter  Daylight Savings Time Adjustment  You sh
4.  for the day is applicable   Proceeding from the time display   1  Press the round button once   2  Press the plus button once to gain access to the    potential fertility display      3  Press the plus button several times to see the potential fertility level for the following 6 days    Reviewing Past Temperature Readings   Fertility Display  Proceeding from the time display   1  Press the round button once  Today s temperature reading alternates with the day of the cycle   2  Press the minus button once  Yesterday s date will be shown alternating with the temperature reading value of that  day   3  Reverse with the minus button   Advance with the plus button   4  By Pressing plus and minus buttons at the same time or if no buttons are pressed for 30 seconds the process will end  and the display will return to the current time of the day        Up to 180 days of previous temperature readings can be retrieved   Mono Phase Cycles  cycles without detected ovulation     If no ovulation is detected  Lady Comp will indicate this to you with a constant solid Red light throughout your window of fertility   No Red Blinking light will be displayed that month     Cycle Statistics  The Lady Comp Can Provide You with Valuable Cycle Data       LEVEL CYCLE STATISTICS  LENGTH OF CYCLE NUMBER OF READ CYCLES INCREASE IN TEMPERATURE  OV RANGE  L 28 0O E12      JF  49      o  82    Proceeding from the time display   1  Press the round button twice   2  The number of saved cycles in the computer
5.  information concerning fertility on every day of the cycle by colored display lights    Red   Potentially Fertile   Yellow   Learning Area and Transition Area  missing temperature reading value  late ovulation  Fertility diagnosis unavailable for  the day    Green   Infertile   Red Flashes   Optimum Fertility    Flashing Red is a prognosis  indicates the identified ovulation from previous closed cycles  Please note  Red light and flashing  red lights indicate potentially fertile days  If you are planning a pregnancy it is advised to have sexual intercourse on  these days  Yellow light indicates that the computer cannot give you a definitive diagnosis on that day     Possible Pregnancy   Lady Comp indicates a possible pregnancy by the simultaneous flashing of the red  yellow and green lights  Within three days  the lights will stop flashing and remain constantly illuminated  Lady Comp indicates a possible pregnancy by the characteristic  pattern of BBT readings  symptomatic of pregnancy  If the Lady Comp has indicated a possible pregnancy  please consult your  medical practitioner as soon as possible     11 Lady Comp Fertility Monitor User Manual    Viewing Advance Potential Forecast Display  Lady Comp indicates the potential fertility for the next 6 days  The actual fertility level for each day can only be confirmed  on the day itself  The prognosis or potential fertility of the following 6 days may change on any one of the 6 forecasted days  The  current fertility diagnosis
6. 50   41 00 Celsius  When the temperature reading is completed it is  confirmed with an acoustical signal and your basal body temperature value appears on the display  If the temperature reading is interrupted  for  example  by moving the thermal sensor in your mouth  the temperature reading is automatically extended  The temperature reading value flashes to  indicate an interruption  Continue with the temperature reading until you hear the acoustical signal  If you do not take your temperature or you would  like to terminate the temperature reading  press the plus and minus button simultaneously  An acoustical signal will sound  the temperature reading  is left out for this day  If the temperature reading value indicates a temperature that is too high  higher than 99 99   or 37 8 C  an    F    for fever appears  on the display  alternating with the temperature reading  It is recommended to interrupt the daily temperature reading in the case of feverish cold or  when taking medications for fever reduction  to avoid entering    abnormal    values into the device     10 Lady Comp Fertility Monitor User Manual    Entering Your Menstruation Data   Confirming or Negating Menstruation    M     After the temperature reading if menstruation the    M    symbol may flash   1  Press the plus button if you are menstruating     M    remains illuminated   2  Press the minus button if you are not menstruating     M    disappears from display   3  Acoustical ring confirms the input  the curre
7. Lady Comp  The    Intelligent    Cycle Computer    Lady Comp is a fertility monitor that determines the fertile and infertile periods occurring throughout a woman s cycle by  assessing the patterns of daily Basal Body Temperature readings and information regarding the dates of menstruation  Hormonal  changes during a woman   s menstrual cycle cause slight increases and decreases in the Basal Body Temperature  A slight  increase in temperature is a signal that ovulation has taken place  Lady Comp effectively identifies a womans fertile period   which is often several days long  Lady Comp considers not only the lifespan of the woman   s egg  24 48 hours   but the fact that  sperm can survive for several days within the vagina and still succeed in fertilizing an egg  Please read this user manual carefully  and completely to ensure safe and effective use of your Lady Comp fertility computer     How to Care for Your Lady Comp   e Lady Comp contains sophisticated technology  You should take care to not drop or damage it  With exception to the power  charger and temperature sensor  both of which can be removed and replaced  do not disassemble the device  Keep it in a safe  dry place  out of the reach of children      Do not expose it to heat  intense cold or sun       Keep the device at temperatures between 50 100   Fahrenheit     Do not immerse in water or place the device under running water     e Keep the temperature probe clean by wiping it daily water   do not use rubbing alcoh
8. ces    14    Lady Comp Fertility Monitor User Manual    
9. e minutes  minus button to reverse    5  Press and hold the round button for 5 seconds  acoustical ring will confirm alarm time    Activate the Alarm  Turning the Alarm On Off  The alarm must be activated before the first temperature    reading   Proceeding from the time display     1  Press the minus button once  The alarm setting appears    2  Press the minus button  the bell symbol flashes    3  Press the plus button   the bell remains constantly illuminated  The alarm will sound at the time set in the previous  step    4  Press the minus button   the bell disappears  The alarm will not sound    5  The Lady Comp alarm starts off quietly and gradually becomes louder and louder    6  The alarm stops when you press any button to take a temperature reading and or automatically after 1 minute       Changing the alarm and temperature reading time  In principle  the device is ready for a temperature reading    1 hour before and after the time of  the previous temperature reading  If you choose an alarm time outside these 2 hours  the temperature measuring time is adjusted to    1 hour in  relationship to the new alarm time  This involves activating the alarm     8 Lady Comp Fertility Monitor User Manual    Enter Your BMI  Body Mass Index  Data  BMI Body Mass Index  Date of Birth  Weight and Height  Entering this data facilitates the cycle evaluation     Proceeding from the time display     1     2   3   4    aon    T     Press the plus and minus buttons for 5 seconds  simultaneou
10. ed with the original power adaptor     Batte   To i the integrated battery of the Lady Comp  it must be connected to the AC power supply for approximately 12 hours   Once fully charged the Lady Comp will operate independent of AC power supply for approximately 1 month  Repeat the  recharging of the battery when BA 9 1 appears on the display  Press the plus and minus buttons simultaneously to return to the  current time display  If the display shows values less than BA 1  the device will not continue to operate     No Risk of Loss of Data  In the event of loss of power or a flat battery  there is absolutely no risk of losing the data stored in the Lady Comp     13 Lady Comp Fertility Monitor User Manual    Deleting Stored Data    To re set device  From current time display  press the plus button 3 times to initiate self test  Now press all 3 buttons  simultaneously until    L 9    displays  Press minus button 9 times  Upon completing these steps all saved data will be deleted     Specifications     Measuring Method  60 second measurement and zero     gradient method    Measuring Range  Fahrenheit 94 1   105 8    Temperature Display  4 Digit  0 01 precision   Power Lithium Battery  3 Volt   Power Supply  Multi range AC power adaptor   110V 230V    Power Consumption  Temperature measuring  and clock  100mA max    Operating Temperature  32 to 95   Fahrenheit   Storage Temperature  32 to 122   Fahrenheit     Device Size  5 5 inches in diameter x one inch     Device Weight  6 9 oun
11. eeen 8 10    Temperature Reading Time Limit  Basal Body Temperature  How to Take Your Temperature  Terminating a Temperature Reading  Fever  Menstruation Data    M       eeren 11  Entering    M    Data  Activating    M     Entering    M    at a Later Date  Correcting    M    Data  Fertility Displays os viedsavcud viewsiaiveeranvhaciveaentvuebins 12  Possible Pregnancy Display  Potential Fertility Display  Retroactive Fertility Display  Mono phase Cycles    Cycle Statistics 0 2    cecccececeeeeeceeeeeeeeeeesenteeeeees 12  Further Information           0  c cccccceeceeeeeeeeeeeeeeeees 13  Back in operation after interruption  Shift Work  Summer and winter time    After taking Birth Control Pill  Abnormal temperature readings  Cleaning the thermal sensor    13 14  Clinical Printout Analysis  Deleting Data  Technical Details  Specifications    Lady Comp Fertility Monitor User Manual    Lady Comp Getting Started   First Steps   Lady Comp contains an integrated lithium rechargeable battery and is equipped with an AC power adapter  Lady Comp cannot  be operated while charging  Please charge Lady Comp for 24 hours before proceeding with set up and operation  Lady comp will  need to be recharged approximately every 30 days for a maximum of 12 hours     Temperature Sensor and Power Charger Connections  Please observe the following sequence  On the underside of the device      1     Insert the electrical connection into the socket A  on the back of the device   Then connect to the AC wa
12. ery  if no buttons are pressed  Lady Comp switches off automatically after 30  seconds       The display will remain dark until a button is pressed or the alarm is activated  Sample values are saved in your Lady Comp  These  values are automatically deleted once you take your first temperature reading  The sample values appear again if you delete all your  personal data     5 Lady Comp Fertility Monitor User Manual    Lady Comp Buttons and Operating Levels    TIME LEVEL    ALARM CLOCK    ALARMTIME TIME   DATE YEAR    off   on   alarm setting set time   set date             5 seconds  O  5seconds    O  5 seconds    hours OQ     hous    20O   O _             _ shortly      shortly       5 seconds          minutes    pe         5 seconds      minutes              press shortly   switch it on            Sseconds           FERTILITY LEVEL          press shortly                      f FERTILITY TEMPERATURE READING VALUE   CYCLE DAY FERTILITY     23 08  97  93 0  97 97     4        gt   0r        yes     M     no        AReverse display up to enter menstruation   advance display up    180 or 250 days f   i to 6 days            Seago          advance   reverse    M      advance   reverse    h  LEVEL CYCLE STATISTICS     press shorty pies oe   LENGTH OF CYCLE NUMBER OF READ CYCLES INCREASE IN TEMPERATURE OV RANGE      t e8    0 E  dU WS JF 49 O O  Ge        press shortly   back to the tme level  Round Button confirm menstruation by pressing              Pressing the round button allow
13. ll outlet  Press  the plus and minus buttons once simultaneously  The time will display    Lady Comp automatically reverts to this display if no further command is entered for 90 seconds or when the plus and  minus buttons are pressed simultaneously    The temperature sensor is inserted in socket B        Recharging the Battery    1     Ore Goh    Insert the AC power supply into connecting socket A   Connect to an AC outlet    Recharge the battery  approx  12 hours     Recharged battery lasts approximately one month   Recharge battery when BA 9 1 is shown on display     Lady Comp Fertility Monitor User Manual    Using Your Lady Comp   Important Reminders      Always take your temperature in the morning  immediately upon awakening  before engaging in any form of physical activity  including moving around  getting up  talking or drinking      The temperature should only be measured orally  by mouth       The alarm must be set on the previous day before 12 AM and must be activated for the first day of use      Stop all birth control hormones before use  The computer functions by identifying ovulation  birth control hormones stop  ovulation      Past menstrual data assist the computer to become more quickly familiar with your individual basal body temperature patterns    e Taking your temperature regularly assists the computer in learning to interpret your individual cycle      During all processes or inquiries you can return to the current time display  at any time  by pressing 
14. ndicator icon will remain illuminated when the alarm is activated    3  Data Display  Time  dates  temperature readings  cycle data      4  Thermometer Symbol  Illuminates during temperature reading time frame and flashes when ready for a temperature reading      5  Menstruation Indicator  Flashes for input          yes or         no menstruation  Remains illuminated with confirmation of menstruation     Please note  Red light and flashing red light indicate potentially fertile days  If you are planning a pregnancy it is advised to have sexual intercourse    on these days  Yellow light indicates that the computer cannot give you a definitive fertility diagnosis on that day     7 Lady Comp Fertility Monitor User Manual    Necessary Steps for Setting up Your Lady Comp    Please proceed proceed with Lady Comp Set Up in the Following Sequence     1  Set the Date and Time 4  Enter BMI  2  Set the Alarm 5  Enter Past Menstruation Data  Optional   3  Activate the Alarm    Setting the Date and Current Time    1  Press the plus and minus buttons simultaneously  time of day will display in military time    2  To enter your current time of day  press and hold the round button for 5 seconds  The hour display will flash  adjust the  time with the plus and minus buttons    3  Press the round button  adjust the minutes with the plus and minus buttons    Press and hold the round button for 5 seconds until you hear an acoustical ring  This confirms your adjustment to the   current time   To e
15. nt cycle day appears on the display alternating with the temperature  reading value for the day       Once Lady Comp becomes familiar with your cycle  it will only ask for    M    data when menstruation is expected  It will begin to request    M    data  approximately two days before your menstruation is expected  Proceed as above to confirm or deny menstruation     Activating    M      If you have    M    on a day that the Lady Comp does not request    M    data    Proceeding from the time display   1  Press the round button  The temperature reading and current cycle day displays   2  Press and hold the round button for 5 seconds     M    flashes   3  Press the plus button     M    remains illuminated     Entering    M    at a later time   If you have not taken a temperature reading for some time  i e  holiday   but you have menstruated during this time proceed as  when entering    past menstruation data      See page 9     Correcting    M    Data  Incorrect    M    data can only be retroactively corrected for the last three days  If you want to correct    M    data  begin with the  furthest date back in time  Proceed as when entering    past menstrual data      See page 9   Negate    M    data with the minus button        When entering past menstrual dates or correcting data  input is only required for the first    M    day  Lady Comp will automatically enter the two  subsequent days     Fertility Displays  Red  Red Blinking  Yellow and Green Indicators   Lady Comp supplies
16. nter the current date  press the plus button once  date will display    Press and hold the round button  the date display will flash  adjust the date with the plus and minus buttons    Press and hold the round button until you hear the acoustical ring which confirms your adjustment to the current date    From the date display  press the plus button once  the year will display  If adjustment is required proceed as above      gt     Co Oo       If the device has already received one or more temperature readings  it is only possible to reverse the date setting by one day  The temperature  readings for the current day and the day before are deleted when the date is reversed  You can always advance the date by one day  This is how you  can correct the date when traveling in a different time zone  Do not take your temperature on the day of travel  It is impossible to change the date by  accident  Once the date has been correctly entered  it automatically proceeds correctly  with adjustments for leap years  The year is automatically  adjusted when you pass 31 12     Setting the Alarm Time  Proceeding from the time display     1  Press the minus button once  The alarm setting time appears on the display    2  Press the round button for 5 seconds until the hour field flashes    3  Press plus button to advance the hour  minus button to reverse  When you reach the hour you wish to wake  press the  round button once to advance to the minute field    4  Press the plus button to advance th
17. ol or detergent     Precautions  e This device is to be used to identify days of increased fertility for conception     e If you do not become pregnant after six months of use  consult with your physician      In no way does Lady Comp provide protection against sexually transmitted diseases    e Lady Comp can be used by women with menstrual cycles lasting between 19 39 days    The menstrual cycle begins on the first day of menstruation and ends on the last day  before the next menstruation     e You should not use the Lady Comp if you are breastfeeding  experiencing symptoms of  Menopause  taking hormonal treatments and or birth control hormones    e Lady Comp may be less effective in identifying fertile days with irregular menstrual cycles      Lady Comp is not approved as a method of birth control   contraception  Consult with your physician if pregnancy is  suspected     1 Lady Comp Fertility Monitor User Manual    Lady Comp Manual Table of Contents    Set Up Instructions               cceececeeeeeeeeeeeereeeeeeeees 3  Connections  Battery  Important Reminders    n    4  Lady Comp Buttons and Operating Levels                 4  Self Testing and Switching On Off             eee 5  Lady Comp Operating Levels      0     ccceceeteeeeeereee 6  Function KOVSixisocestesscteeveercaa tnecdsvterdarsecaebeniastan  6  Lady Comp Display           0   ccceceeteeeeeeeteeteeeeees 7  Necessary Settings before You Begin                 6 8  Temperature Reading          0  cccceseeeeetteeete
18. ould advance or reverse the time to summer or winter time     Using Lady Comp after Using Hormone based Birth Control or Other Synthetic Hormones  You must stop taking birth control hormones before you begin to use Lady Comp  The first bleeding after stopping birth control  hormones is a withdrawal bleeding  It is not a natural menstruation  Do not enter    M    for this bleeding     Abnormal Temperature Readings   Abnormal temperatures caused by illness  excessive alcohol consumption  medications that cause an increase or decrease in  temperature are recognized by the Lady Comp  In general  it is recommended to interrupt the daily temperature  if it is  recognized as abnormal  to avoid storing the abnormal temperature reading  If the temperature reading value indicates a  temperature that is too high  higher than 99 99   or 37 8 C  an    F    for fever appears on the display  alternating with the  temperature reading  It is recommended to interrupt the daily temperature reading in the case of feverish cold or when taking  medications for fever reduction  to avoid entering    abnormal    values into the device     Cleaning the thermometer  The thermal sensor should be cleaned daily by wiping with regular water  Do not use rubbing alcohol or detergents to clean the    sensor     Clinical Print out Analysis  You can receive a Clinical print out of your last 180 days stored in the Lady Comp  Contact your distributor for details     Technical Details  The device should only be us
19. s you to  change the operating levels      Pressing the round button allows you to  make adjustments to the settings     To adjust settings      Press and hold the round button for 5  seconds  the display will flash      The setting can be changed by pressing  the plus or minus button      Press and hold the round button for 5  seconds  when you have completed the  adjustment    e The adjustment is confirmed  flashing  stops and you hear an acoustical signal     Plus Button  e Pressing the plus button advances the    data displayed     Pressing the minus button confirms data   For example  when    M    flashes you    Minus Button  e Pressing the minus button reverses the    data displayed  For example to look at  past dates  temperature readings and  evaluations    e Pressing the minus button corrects  data  For example when    M    flashes  you can answer    no     to menstruation by  pressing the minus button     To Return to Start Position  e Pressing the plus and minus buttons at    the same time will return you to the start  position  the current time display     Fast Mode    e Pressing and holding the plus or minus  button allows you to fast advance or reverse     Lady Comp Fertility Monitor User Manual    Lady Comp Display    4 4     2   8 88  3    M  5    LADY       O        1  Fertility Indicators   Red     Fertile    Red Blinking     Window of ovulation   Yellow      Learning    fertility diagnosis unavailable   Green     Infertile    2  Alarm indicator  The alarm i
20. sly  The year of birth appears the birth symbol lights up   Press and hold center button until display flashes  adjust with plus minus buttons to the correct year of birth    Press and hold the center button for 5 seconds to confirm    Press the center button quickly  Press and hold the center button until display flashes  adjust with plus minus buttons to  enter your height    Press and hold the round button for 5 seconds to confirm    Press the round button quickly  Press and hold the center button until display flashes  adjust with plus minus buttons to  enter your weight    Press and hold the round button for 5 seconds to confirm  Press center button quickly to view BMI calculation     Enter Past Menstruation Data     M    Data  Optional    If you have    M    data from previous cycles  you must enter this data into the device before the first temperature reading  Only  the first day of    M    is to be entered per cycle  the device saves automatically three    M    days  Begin with the input of the furthest  menstruation back in time     Proceeding from the current time display     1     2   3   4     Press the round button  Now you are in the Fertility Level    Press the minus button until you reach the date of menstruation data  furthest back    Press and hold the round button for 5 seconds     M    flashes    Press the plus button to confirm    M     Continue to the next date of menstruation data  moving forward to the current  date  confirming each cycle   s first   
21. the plus and minus  buttons at the same time     Please note  Red light and flashing red lights indicate potentially fertile days  If you are planning a pregnancy it is advised to have sexual intercourse  on these days  Yellow light indicates that the computer cannot give you a definitive fertility diagnosis on that day     Display    Function keys    Sensing device       y Sensor    4 Lady Comp Fertility Monitor User Manual    Self testing and Trial readings    Directions for Performing a Self Test  Lady Comp self tests by sequentially illuminating all displays  Proceeding from the time display   1  Press the plus button 3 times     Lady Comp illuminates each display symbol    When the test is completed the time appears and the thermometer symbol remains illuminated    If you press the round button  the thermometer will flash and Lady Comp is ready for a temperature reading   If no trial temperature reading is required  press the plus and minus buttons simultaneously     D Or ON    The current time will now display     Switching the Lady Comp ON OFF  Turn ON  1  Press any button    2  The current time will be shown    Automatic Off  e If you do not press any button for 30 seconds  the display automatically returns to the time     e When you press the plus and minus buttons simultaneously  the display will return to the time    e When using the AC power adaptor  the device will return to the pre set dimming level after 30 seconds    e When operating with the rechargeable batt
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Xerox Phaser 7300 User's Manual  Manual de Segurança e Higiene do Trabalho  Operation & Maintenance Manual  CB-500A Series User's Manual  Wharfedale Zaldek Surround User's Manual    Whirlpool Signature SS25AQXHW00 User's Manual  Evo Quattro Led  intext:Installationsanleitung filetype:pdf    Copyright © All rights reserved. 