Product Datasheet

image

Contents

1. 2 8 8 6 00h 1 0 disabled 8 6 00h 1 1 1 140 32 12 3 000h N O Response Data Vendor Id Serial Number Attribute ID Attribute Descriptor Number of diagnostic bits enabled in attribute 9 Attribute Input variable Attribute Input variable Holjeron e 25599 SW 95 Avenue Suite E e Wilsonville OR 97070 e 503 582 0820 e Fax 503 582 9166 e www holjeron com
2. 6 e www holjeron com Holjeron smart moves BBK 4040 5 Diagnostics The Diagnostics Register attribute 9 is one byte and contains the minimum diag nostics required for the Smart Distributed System Diagnostic Register Bit Definitions Byte 0 Bit Name Description D CHKSUM ROM checksum error 1 WDOG Output watchdog timer expired 2 BUSOFF Off us communications error 3 DEVERR Fatal component error 4 NODE Missing node detected 5 RSVD Reserved 6 RSVD Reserved 7 EPRM EEPROM error de tected SDS host controllers are equipped to re ceive a diagnostic event then automati cally obtain the information from the Di agnostic Register attribute 9 Consult the documentation for the host controller being used to determine how errors are handled BusBlock Digital I O Module Page 5 CHKSUM A ROM checksum error is generated on power up if there is a memory error test WDOG The WDOG diagnostic occurs whenever the Output Watchdog Timer attribute 50 times out The Output Watchdog Timer is reset whenever the BusBlock module receives a message over SDS If a message is not received in the time entered any point configured as an output will be set to the state for that bit in the Default Output attribute 51 The Output Watchdog Timer is entered in increments of 10 milliseconds 0 01 sec onds For example a value of 100 equals 1 second BUSOFF
3. Holjeron smart moves BusBlock Digital I O Module for the Smart Distributed System BBK 4040 5 0104 TECHNICAL DATA Description The Holjeron BusBlock I O Module is de signed to handle small amounts of UO in a limited amount of space The BusBlock S222 PERSE ES IO Module comes in two versions twelve gt dell inputs eight outputs and eight inputs six Holjeron Wer relay outputs All I O is optically isolated BusBlock from the bus l Field terminations are captive screw ter minals Each input and output has its own ece LED indication for immediate verification E soosoo ss of I O states W EGG SSS kikik ttr Specifications Part Numbers 12 Input 8 Output BBK DIG128 Warranty Remedy 8 Input 6 Relays BBK DIGO86 Seller warrants its products to be free Electrical Gen SE dee in a ce from defects in design material and E On Sumpuen m workmanship under A use and Data Rates 125 250 500 and 1000 kbps Sell ill Inputs Type Current Sinking Sourcing load pee ee IN Epal OF MEP aS Number BBK DIG128 Twelve 12 without charge any such products it BBK DIG086 Eight 8 finds to be so defective on its return to Voltage Range 10 28 VDC Seller within 18 months after date of Maximum Current 20 mA per input shipment by Seller The foregoing is Isolation 1500 Vrms in lieu of all other expressed or im Outputs DIG128 Type Current Sinking plied warranties except title in Number Eight 8 cluding
4. Model Vendor Id Logical Address Unsolicit Mode Software Version Diagnostic Counter Diagnostic Register Cyclic Timer Serial Number Date Code Catalog Listing Vendor Description Input Variable Output Variable Output Watchdog Timer Default Output Reset Count Service Time Manufacturing Codes Tag Name Input NO NC Description NOOP Change Address Self Test Clear All Errors Enroll Logical Device Change Baud Rate Force State Remove Forced States Read Attribute Descriptor Password Reset Factory Defaults Description Diagnostic Event End Of Timer Change of Value NOOP BusBlock Digital I O Module for the Smart Distributed System Data Type Size Unsigned Byte Unsigned Byte Unsigned Byte Unsigned Word Unsigned Byte Boolean Undef Character Undef Unsigned Byte Unsigned Byte Unsigned Word Unsigned Long Character Undef Character Undef Character Undef Character Undef Boolean Undef Boolean Undef Unsigned Word Boolean Undef Unsigned Word Unsigned Word Unsigned Byte Character Undef Boolean Undef SSVVVSSSDSvvVUVsS says vvIIAIs Request Data New logical address 0 125 Address New baud rate 0 4 Input variable value 0 4095 Attribute Id 0 255 Password Event Data TECHNICAL DATA Count Default 6 Dependent on product 1 0 autobaud 4 1 41 5 4 1 9 Holjeron 1 125 1 1 enabled 12 1 1 1 0 disabled 1 4 32 BBK DIG128 086 32 Holjeron 32 BusBlock I O Module 1
5. The CAN controller on the BusBlock module counts error messages Every er ror message increments a counter by 8 every good message decrements the counter by 1 If the counter reaches 128 then the module will go BUSOFF and will need to be reset by the host controller DEVERR The DEVERR diagnostic bit will be set if a fatal error is detected within the compo nent NODE The host controller will report the node is missing using the NODE bit EPRM The EPRM error will occur when the mi croprocessor on the BusBlock module is unable to read or write EEPROM for the Smart Distributed System TECHNICAL DATA Other Useful Diagnostics BusBlock modules are equipped with two attribute settings for managing the service life of the module The first Reset Count attribute 53 is the number of times the module has been reset This can be due to a power cycle or to some other external factor A prod uct on a network that is being reset more often than other products on the same network is experiencing difficulties and should be replaced The second Service Time attribute 54 is the number of hours the module has been in operation Holjeron e 25599 SW 95 Avenue Suite E e Wilsonville OR 97070 e 503 582 0820 e Fax503 582 9166 e www holjeron com Holje BBK 4040 5 Attributes Actions Events ron smart moves G D JO P Go A OH NOW CH Page 6 Description Network Data Descriptor Baud Rate Object
6. Wiring BBK DIG128 TOP VIEW 10 30 VDC OUTPUT WIRING le 5 50 gt he rT z e e 5 e SDS CONNECTOR 3d l 6 l 6 o ol sl al ol l 2 12 2 2 2 2 8 8 8 2 o 8 oun S S E Q 19 Q 9 J2 DC DC Bus Bus Outo 3 47 Ing Ing Ve Vin Out4 Ing Ind In7 COM Ino Int O O O O O O O O OTO OTO OOOO Qjo OO nd F END VIEW INPUT WIRING La 3 53 gt BBK DIGO86 r Ee K 10 30 VDC TY SDS CONNECTOR 2 27 olololo G OOO DC DC Bus Bus v Tv ENEE ICOM COM COM COM V V TIT y In4 In5 In6 In7 one og oe ene Ind Int In2 Ind tritt OOO Ok do ive L OUTPUT WIRING lg sl vial ei gl el el al e S S 4 EIS Typical of gi Q by bd S 10 125 VDC INPUT WIRING 24 240 VAC gt Holjeron e 25599 SW 95 Avenue Suite E e Wilsonville OR 97070 e 503 582 0820 e Fax503 582 9166 e www ho
7. a BusBlock I O Module to generate an event whenever one or more inputs change state This re quires the Unsolicit Mode attribute 6 be enabled by setting its value to 1 Other options are to disable change of value events Unsolicit Mode 0 or use the Cyclic Timer Attribute 10 by setting it to some non zero value The Cyclic Timer will transmit the input variable on an inter val equal to the value in the Cyclic Timer attribute times 10 milliseconds 0 01 sec onds Input NO NC The BusBlock Digital UO Module can be configured to invert the state of an incom ing input point by turning on the corre sponding bit in Input NO NC attribute 60 for the Smart Distributed System TECHNICAL DATA Outputs Bit Name Description D Out Output 0 1 Out Output 1 2 Out2 Output 2 3 Out3 Output 3 4 Out4 Output 4 5 Out5 Output 5 6 Out6 Output 6 DIG128 Only 7 Out7 Output 7 DIG128 Only Outputs received by the BusBlock from the host controller are processed per the chart below SDS Output Value Update Output Variable Attribute 34 Output Change of State Output Variable Attribute 34 functions as the output at tribute for the BusBlock Digital I O Mod ule Whenever the host controller changes the state of an output it is writing to attribute 34 Holjeron e 25599 SW 95 Avenue Suite E e Wilsonville OR 97070 e 503 582 0820 e Fax503 582 916
8. ent to a complete bus This will help prevent duplicate addresses on a bus Note When using a packaged control sys tem such as Think amp Do Software it is not necessary to explicitly read input and output variables The SDS I O Driver and Interface Card perform this function All that is required is to map inputs and outputs as described in the software user manual Holjeron e 25599 SW 95 Avenue Suite E e Wilsonville OR 97070 e 503 582 0820 e Fax 503 582 9166 e www holjeron com Holjeron smart moves BBK 4040 5 Inputs Bit Name Description 0 Ind Input 0 1 Int Input 1 2 In2 Input 2 2 In Input 3 4 In4 Input 4 5 Ind Input 5 6 In Input 6 7 In7 Input 7 8 In8 Input 8 DIG128 Only 9 Ing Input 9 DIG128 Only 10 In10 Input 10 DIG128 Only 11 Int Input 11 DIG128 Only The BusBlock Digital UO module proc esses inputs as follows Input Change of State NO NC Attribute 60 Yes y Invert Input Y Update Input Variable Attribute 18 nn GE Change of Value Event SDS BusBlock Digital I O Module Page 4 Input Variable Attribute 18 functions as the input attrib ute for the BusBlock Digital I O Module Whenever an event is generated that re ports the state of inputs the data in at tribute 18 will be passed Input Event Mode Most systems will require
9. ljeron com Holjeron smart moves BBK 4040 5 Configuration A BusBlock module can be configured us ing several tools The information below summarizes the configuration tools avail able and hardware requirements for each tool Holjeron Device Manager for SDS Requires an HSIM Portable RS 232 to CAN converter that connects to the serial port of a personal computer The bus or the HSIM Portable must have power Honeywell hand held activator The Honeywell activator may not supply enough power by itself The SDS bus might require external power to be ap plied Think amp Do Software Requires a Honeywell PC Interface Card with separate bus power Follow the in structions for installing the SDS Driver in UO View BusBlock Digital I O Module Page 3 Quick Start The following steps are the minimum steps to configure BusBlock module Default values are shown in bold type face Set Device Address Using one of the tools described above change the device address from the de fault All units are shipped from the fac tory as address 126 for the Smart Distributed System TECHNICAL DATA Operation BusBlock modules are simple digital in put output devices Each input and output is available to the host controller There are minimal configuration options to affect the behavior of the BusBlock Module as described on the following pages Note Set the address before attaching any compon
10. those of merchantability Mate ee SC and Wee Be a Ae pur Isolation 1500 Vrms pose The foregoing is also pur DIGO86 Type Relay chaser s sole remedy and is in lieu of Number Six 6 all other guarantees obligations or li Voltage Range 10 125 VDC 24 240 VAC abilities or any consequences inciden Maximum Current 2 Amps 115 VAC tal or punitive damages attributable to Isolation 1500 Vrms negligence or strict liability all by way Environmental Temperature Storage 30 to 70 C 22 to 158 F of example E Operating 0 to 60 C 32 to 140 F Humidity 5 95 RH non condensing While Holjeron provides application Vibration 2G at 10 to 500 Hz assistance personally and through Shock 10G our literature it is up to the customer Physical Dimensions 5 50 H x 3 48 W x 1 00 D to determine the suitability of the horia e T roduct in the application wor one aray P Pp Case Material Polycarbonate All information contained herein in Mounting DIN Rail or foot mount cluding illustrations specifications and Terminations Captive Screw Terminal dimensions is believed to be reliable Indication Bait Sc as of the date of publication but is eno som subject to change without notice VO Green Holjeron e 25599 SW 95 Avenue Suite E e Wilsonville OR 97070 e 503 582 0820 e Fax 503 582 9166 e www holjeron com Holjeron BusBlock Digital I O Module smart moves for the Smart Distributed System BBK 4040 5 Page 2 TECHNICAL DATA Dimensions