Home
Badger Meter Model 310 Analog Transmitter Manual PDF
Contents
1. rj Cancel To go to calibration settings screen select Parameters from ether place shown b bed IET MEI pme 6 Program using diagram below as a reference Note 1 Sdi If the SDI sensor type is selected the required K and offset values can be found the the SDI owners manual 4000 If the 4000 sensor type is selected click the choose button and select the sensor from the pull down box that appears Sine Provided for connection to sensors which have a sine wave output Please consult sensor manufacturer for the calibration settings 200 Insert Type If the 200 Insert Sensor type is selected the required K and offset can be found the the 200 owners manual or if the manual is not handy the calculate button can be pushed and an inside pipe diameter can be entered and once calculate is pressed a K and offset will automatically be entered in 200 Tee Type If the 200 tee type is selected click the choose button and select the sensor from the pull down box that appears Model 310 Specifications Power Requirements Loop Input Voltage 9 35VDC Input Frequency 0 4 to 10 KHz Load Resistance Max 7500 p24VDC Output Response Time Varies with filter Temperature operating 29 C to 70 C 20 F to 158 F Temperature storage 40 C to 85 C 40 F to 185 F Accuracy 0 04 of reading over entire span Linearity 0 1 of full scale Warranty Data Industr
2. by any means graphic electronic or mechanical including photocopying recording taping or information and retrieval systems without written permission of Data Industrial Due to continuous research product improvements and enhancements Badger Meter reserves the right to change productor system specifications without notice except to the extent an outstanding contractual obligation exists BadgerMeter Inc P O Box 581390 Tulsa Oklahoma 74158 918 836 8411 Fax 918 832 9962 www badgermeter com
3. Badger Installation amp Loop Powered Analog Output Model 310 Transmitter Operation Manual gt BadgerMeter Inc 872009 Rev 6 4 09 Mechanical installation The Model 310 may be surface mounted onto a panel attached to DIN rails using adapter clips or wall mount ed using two optional enclosures Location Although the Model 310 is encapsulated all wiring connections are made to exposed terminals The unit should be protected from weather and moisture in accordance with electrical codes and standard trade practices In any mounting arrangement the primary concerns are ease of wiring and attachment of the programming cable The unit generates very little heat so no consideration need be given to cooling or ventilation Figure 2 310 Optional Enclosure Dimensions Surface Mount Installation The Model 310 may be mounted to the surface of any panel using double sided adhesive tape or by attaching fasteners through the holes in the mounting flanges of the unit DIN Rail Mounting Optional clips snap onto the mounting flanges allowing the Model 310 to be attached to DIN 15 32 35 mm DIN rail systems Wall Mounting Optional metal and plastic enclosures are available to mount the Model 310 to a wall when no other enclosure is used The enclosure is first attached to the wall using fasteners through its mounting holes After wiring the transmitter may be attached to the enclosure with the terminal headers fa
4. I Protection connect Model 310 ground lug to panel ground See Note 1 7 Ensure that all connections are tight then plug con nector into header Note 1 Included with every Model 310 is a 310IK kit contain ing a screw lock washer and ground lead to connect the Model 310 to Earth Ground This will help prevent electrical interference from affecting the Model 310 s normal operation Suri WC cR Re E bak ins ceres AU Fea a CEN So res OM nw Figure 4 Model 310 Wiring to Analog Loop and Series 200 or Series 4000 Communications cable wiring Field calibration requires a Data Industrial A310 Pro gramming kit consisting of a custom cable and soft ware and a PC running Windows 9x ME NT 2000 or XP In order to program the Model 310 it must be connected to Loop ip Power and the A301 cable must be con nected between the Model 310 Comm port connector and an available DB9 COM port on a computer Dic i Communications Pari Location of the DIC Communication Port Note The Data Industrial A301 Cable will work with all 300 Series products However the older version of the cable A300 does not have sufficient bandwidth to work with the newer 340 Series Transmitters or SDI Flow Sen sors Data Industrial provides free programming software up dates via the Internet for all of 300 Series devices Go to www dataindustrial com for these updates Programming Software Installation Floppy Installa
5. cing in using the slots in the mounting flanges As an alternate mount ing arrangement the Model 310 may be fastened to the box cover using double sided adhesive tape Model 310 Electrical Installation Per standard wiring practices the loop power must be off before making any wire connections The terminal 2 strips have removable plug in connectors to make wir ing easier 1 Refer to Figure 3 for terminal connections 2 As shown in figure 4 connect loop power supply positive to Model 310 terminal marked 4 20mA s Lomman ears Por loop Figure 3 Model 310 Terminal Locations 3 Connect terminal marked 4 20mA loop of Model 310 to positive analog terminal of input device Chart Recorder PLC etc 4 Connect negative analog terminal of input device to loop power supply negative 5 If Wiring a Series 200 it sensor connect the red k wire signal to Signal terminal black wire com mon to Signal terminal _ and the shield to Shield zx Ground terminal Disregard shield for the IR sensors Ones Coe Side View Typical 300 Se ries Removable Connector If Wiring a Series 4000 sen Wiring sor connect the clear wire signal to Signal terminal black wire common to Signal terminal shield wire to Shield Ground termi nal and red wire power to Power 4000 only terminal If wiring to a sine wave output sensor consult factory 6 For maximum EM
6. de If Buyer or Purchaser wishes to make a claim hereun der he shall send written notice of any defect within the warranty period to Seller at the above address Seller may at its sole option instruct Buyer to ship subject part postage prepaid to the Seller at above address or authorize a representative to inspect the part on site Seller will at its sole option repair or replace any defective product covered by this warranty If Buyer makes repairs or alterations to any product or part covered by this warranty without Sellers prior written approval this warranty shall be null and void The foregoing shall constitute Buyers or Purchasers sole and exclusive remedy against Seller and no other remedy including but not limited to incidental or consequential damages for personal injury loss of fluids gases or other substances or for loss of profits or injury to property or person shall be available to the Buyer or Purchaser The warranty extended herein shall be in lieu of any other implied warranty of mer chantability or fitness for a particular purpose and seller shall bear no liability for representatives or retail sellers In no event shall Data Industrial Corporation be liable for any contingent incidental or consequential damage or expenses due to partial or complete inoperability of its product All rights reserved No part of this work covered by the copyrights hereon may be reproduced or copied in any form or
7. ial Corporation Seller of 11 Industrial Drive Mattapoisett Massachusetts 02739 0740 U S A warrants to the original purchaser of its prod uct that such product manufactured by Data Industrial Corporation shall be free from defects in materials or workmanship when installed serviced and operated according to Data Industrial Corporation instructions or in other such normal use This warranty is effective for a period of 12 months from the date of installation by the Purchaser or 18 months from the date of shipment by the Seller whichever occurs or terminates first This limited warranty does not cover damage or loss result ing from corrosion or erosion caused by acids or other chemicals or by severe environmental conditions or negligent or improper installation or improper operation misuse accident unauthorized repair or substitution of components other than those provided by the Seller and does not cover limited life components such as bearings shafts impellers where wear rate is a function of application and environment Any component not manufactured by the Seller but included in its products Badger and Data Industrial are registered trademarks of Badger Meter Inc Data Industrial Please see our website at www badgermeter com for specific contacts Copyright Badger Meter Inc 2009 All rights reserved shall not be covered by this warranty and is sold only under such warranty as the manufacturer may provi
8. tion Place the software installation Disk 1 into the floppy drive and run the setup exe program to install CDROM Installation Place the software CD into the CDROM drive and it should autostart Click programming software then click the Model 310 and the software installation will begin Web Installation The Installation software can be found at the Data Industrial web site www dataindustrial com in the sup port section Model 310 Programming Programming the Model 310 is accomplished by install ing the Data Industrial programming software on a com puter and entering data on templates of the Windows based program 1 Install the 310 PC Interface Software into the com puter 2 Connect the computer to the Model 310 transmit ter using the Data Industrial A301 communications cable Plug A301 cable to the socket labeled D I C Comm Port taking care to properly align the tab on the plug and socket to maintain polarity then plug the DB9 connector of the Data Industrial A301 communications cable to an avaliable PC com port that has the Model 310 software installed 3 Connect the Model 310 transmitter to a powered 4 20mA loop if setting up in the office a 9 24VDC power source can be used to simulate the loop 4 Open the interface software and select the appro priate COM PORT as shown in the dialog box below Select Port 4 x The configured senal port rs not valid Please choose another port com