Home

Digital Phosphor Oscilloscopes

image

Contents

1. P5205 1 3 kV 100 MHz high voltage differential probe P5210 5 6 kV 50 MHz high voltage differential probe P5100 2 5 kV 100X high voltage passive probe ADA400A 100X 10X 1X 0 1X high gain differential amplifier NEX HD2HEADER Mictor connector breakout to 0 1 header pins Recommended Accessories 071 1844 XX Service manual English only SIGEXPTE NI LabVIEW SignalExpress Tektronix Edition Software Full Version FPGAView xx MSO Support for Altera and Xilinx FPGAs TPA BNC TekVPI to TekProbe BNC Adapter TEK USB 488 GPIB to USB Adapter TLAHRA with 2 196 3476 01 High Impedance Adapter and Leadsets for P6515 MSO Probe 119 6827 00 CompactFlash to USB Memory Card Reader ACD4000 Soft Transit Case HCTEK4321 Hard Transit Case Requires ACD4000 RM4000 Rackmount Kit AMT75 3 1 GHz 75 Q Adapter Warranty Three year warranty covering all parts and labor excluding probes 1 Language options include translated front panel overlay for the selected language s 2 Probes and accessories are not covered by the oscilloscope warranty and Service Offerings Refer to the datasheet of each probe and accessory model for its unique warranty and calibration terms For Further Information Tektronix maintains a comprehensive constantly expanding collection of application notes technical briefs and other resources to help engineers working on the cutting edge of technology Pl
2. Standard Deviation Reference Levels User definable reference levels for automatic measurements can be specified in either percent or units Gating Isolate the specific occurrence within an acquisition to take measurements using either the screen or waveform cursors Waveform Math Arithmetic Add subtract multiply and divide waveforms Math Functions Integrate Differentiate FFT FFT Spectral magnitude Set FFT Vertical Scale to Linear RMS or dBV RMS and FFT Window to Rectangular Hamming Hanning or Blackman Harris Advanced Math Define extensive algebraic expressions including analog waveforms math functions scalars up to two user adjustable vari ables and results of parametric measurements e g Intg Ch1 Mean Ch1 x 1 414 x VARI testpatn Test Equipment Accessories Software NI LabVIEW SignalExpress Tektronix Edition LE A fully interactive measurement software environ ment optimized for the 4000 Series enables you to instantly acquire generate analyze compare import and save measurement data and signals using an intuitive drag and drop user interface that does not require any programming Standard 4000 Series support for acquiring controlling viewing and exporting your live signal data is permanently available through the software The full version SIGEXPTE adds additional signal processing advanced analysis mixed signal sweeping limit testing and user defined step Capabiliti
3. Tektronix 4000 Family e DPO4000 Series e MSO4000 Series Has Multi channel setup and hold triggering highlighting multiple violations MSO4000 The 4000 Series offers a vanety of analytical solutions including cursors 29 automatic measurements statistics and waveform math Despite a tiny footprint only 5 4 in deep and light weight 11 lbs the 4000 Series offers exceptional performance a large 10 4 XGA display and knob per channel vertical controls The TekVPI probe interface sets the standard for ease of use in probing TekVP probes feature status indicators and controls as well as a probe menu button right on the comp box itself This button brings up a probe menu on the oscilloscope display with all relevant settings and controls for the probe The TekVP interface utilizes a new probe power management architecture enabling direct attachment of current probes without requiring a separate bulky power supply Finally TekVP probes can be controlled remotely via USB GPIB or Ethernet enabling more versatile solutions in ATE environments P Triggering on a specific data packet going across an RS 232 bus Bus waveform provides decoded packet content displayed in ASCII MagniVu The main digital acquisition mode on the MSO4000 Seres will capture up to 10 M points at 500 MS s 2 ns resolu tion In addition to the main record the MS0O4000 provides an ultra high reso lution mode called Mag
4. as far as possible this indicates that increasing the sample rate on the next acquisition will reveal higher frequency information than the previous settings could acquire Digital Phosphor Oscilloscopes gt Tektronix 4000 Family e DPO4000 Series e MSO4000 Series Groups are created by simply placing digital channels together on the screen You can position and set threshold values for a group in a single step P Clocked parallel bus display decoding a 7 bit counter Channel setup on an MSO can often be time consuming as compared to the traditional oscilloscope This process often includes probing the device under test labeling the channels and positioning the channels on screen The MSO4000 simplifies this process by allowing the user to group digital waveforms and enter waveform labels via USB keyboard By simply placing digital waveforms next to each other they form a group Once a group is formed you can position all the chan nels contained in that group together This greatly reduces the normal setup time associated with positioning chan nels individually gg estpatn Digital Phosphor Oscilloscopes gt Tektronix 4000 Family e DPO4000 Series e MSO4000 Series Tektronix M50 4104 Mixed Signal Oseillaacepe Bi oo eee gt Eee a R 1 Zoom Pan Dedicated front panel controls for l zooming and panning The inner knob controls zoom factor while the outer ring adjust pans the zoom box across
5. volts div settings Vertical System MSO4032 MSO4034 MSO4054 MSO4104 Digital Channels Input channels 16 Digital D15 to DO Thresholds Per Channel Thresholds Threshold Selections TTL CMOS ECL PECL User Defined User Defined Threshold Range 5 to 2V Maximum Input Voltage 15V Threshold Accuracy 100 mV 3 of threshold setting Input Dynamic Range 6 V centered around the threshold Minimum Voltage Swing 500 mV Input Impedance 20 kQ Probe Loading 3 pF Vertical Resolution 1 bit Horizontal System MSO4032 DPO4034 DPO4054 DPO4104 Analog Channels MSO04034 MSO4054 MSO4104 Maximum Sample Rate 2 5 GS s 2 5 GS s 2 5165 5 5 GS s all channels Minimum Peak Detect 400 ps 400 ps 400 ps 200 ps Pulse Width Maximum Record Length 10 M points all channels Maximum Duration at Highest 4 ms 4 ms 4ms 2ms Sample Rate all channels Timebase Range 1 ns to 400 s 400 ps to 400 s Timebase Delay Time Range 10 divisions to 50 s Channel to channel Deskew Range 100 ns Timebase Accurac 5 ppm over any 1 ms interval a ua th ea estpath Digital Phosphor Oscilloscopes gt Tektronix 4000 Family e DPO4000 Series e MSO4000 Series Horizontal System MSO4032 MSO4034 MSO4054 MSO4104 Digital Channels Maximum Sample Rate Main Maximum Record 500 MS s 2 ns resolution 10 M points Length Main Maximum Sample 16 5 GS s 60 6 ps resolution Rate MagniVu 10 k points centered on the trigger Length MagniVu Maximum Record M
6. 0 Family e DPO4000 Series e MSO4000 Series Other Applications Video Design and Development Many video engineers have remained loyal to analog oscilloscopes believing the intensity gradations on an analog display are the only way to see certain video waveform details The 4000 Senes fast waveform capture rate coupled with its intensity graded view of the signal provides the same information rich display as an analog oscilloscope but with much more detail and all the benefits of digital scopes ikkitali P OpenChoice Desktop Standard software seamlessly connects the 4000 Series to a PC Standard features such as IRE and mV graticules holdoff by fields video polarity and an Autoset smart enough to detect video signals make the 4000 Series the easiest to use oscilloscope on the market for video applications And with up to 1 GHz bandwidth and four analog inputs the 4000 Series provides ample performance for analog and digital video use CHA shew rate CHI freq Hz 1 31630M OCC P Ni LabVIEW SignalExpress Tektronix Edition SIGEXPTE Fully interactive meas urement acquisition and analysis software developed jointly with NI and optimized for Finally the 4000 Series video function the 4000 Serres ality is further extended with the optional DPOAVID video application module DPOAVID provides the industry s most complete suite of HDTV and custom non standard video triggers gt aE uN Ex
7. 9 336 EEC Safety UL61010 1 Second Edition CSA61010 1 Second Edition EN61010 1 2001 IEC 61010 1 2001 gt Ordering Information 4000 Family DPO4000 Models DPO4034 350 MHz 2 5 GS s 10 M record length 4 channel digital phosphor oscilloscope DPO4054 500 MHz 2 5 GS s 10 M record length 4 channel digital phosphor oscilloscope DPO4104 1 GHz 5 GS s 10 M record length 4 channel digital phosphor oscilloscope MSO4000 Models MS04032 350 MHz 2 5 GS s 10 M record length 2 16 channel mixed signal oscilloscope MS04034 350 MHz 2 5 GS s 10 M record length 4 16 channel mixed signal oscilloscope MS04054 500 MHz 2 5 GS s 10 M record length 4 16 channel mixed signal oscilloscope MS04104 1 GHz 5 GS s 10 M record length 4 16 channel mixed signal oscilloscope All models include One P6139A 500 MHz 10x Passive Probe per Analog Channel Front Cover 200 4908 00 CompactFlash Memory Card 32 MB 156 9413 00 User Manual 071 2121 xx Documentation CD 063 3903 00 OpenChoice Desktop Software NI LabVIEW SignalExpress Tektronix Edition LE Software Calibration certificates document measurement traceability to National Metrology Institute s the Quality System this product is manufactured in is IS09001 registered power cord accessory bag 016 1967 00 and a three year warranty Please specify power plug and manual version when ordering MSO models also include one P6516 16 channel logic probe a
8. Digital Phosphor Oscilloscopes gt Tektronix 4000 Family e DPO4000 Series e MSO4000 Series gt Tektronix 4000 Family Tektronix 4000 Series Digital Phosphor Oscilloscopes The 4000 Family includes the DPO4000 Series and the MSO4000 Series The DPO4000 Senes Digital Phosphor Oscilloscopes DPOs are the first oscilloscopes to offer usable deep memory on all channels excellent performance serial trigger and analysis options and all in the most compact form factor in their class The MS04000 Series Mixed Signal Oscilloscopes MSOs provide all the features and benefits of the DPO4000 but add 16 integrated digital channels enabling you to visualize and correlate analog and digital signals on a single instrument This integration extends triggering functionality across all 20 channels providing pattern and state triggering ideal for debugging mixed analog and digital designs Designed to Make Your Work Easier As design complexity increases you need tools that help you find problems quickly Easy to Set up and Use The 4000 Series has a large 10 4 inch XGA display a clean front panel with familiar Knobs all in a package that is only 5 4 in deep and weighs only 11 lbs With USB plug and play opera tion and PC connectivity acquiring data and measurements from the instrument IS aS Simple as connecting a USB cable from the oscilloscope to the PC Provided applications include NI LabVIEW SignalExpress Tektronix
9. Edition LE OpenChoice Desktop and Microsoft Excel and Word toolbars enabling fast and easy direct communi cation with your Windows PC USB and CompactFlash ports on the front panel enable simple transfer of screen shots instrument settings and wave form data in the palm of your hand When it comes to mixed signal design and debug you want your instrument to be intuitive so you can start solving problems quickly The MSO4000 Series drives like an oscilloscope the tool you already know how to use You do not have to relearn how to use the instru ment every time you turn it on gt Features amp Benefits Key Performance Specs 1 GHz 500 MHz 350 MHz bandwidth models 2 or 4 channels 16 digital channels MSO4000 Suite of advanced triggers Sample rates up to 5 GS s on all channels 10 Mega sample record length on all channels 50 000 wfm s maximum waveform capture rate Ease of Use Features Wave Inspector Controls provide unprecedented efficiency In waveform analysis 10 4 in 264mm XGA color display Small footprint and light weight only 5 4 in 137mm deep and 11 Ibs 5 kg USB and CompactFlash on front panel for quick and easy storage Plug and play PC connectivity Serial Triggering and Analysis I2C SPI CAN LIN FlexRay and RS 232 422 485 UART serial triggering and analysis options Mixed Signal Design and Analysis MSO4000 Parallel bus trigger and analysis MagniVu 60 6 ps techn
10. at their predecessors parallel buses did not face They make debugging bus and system problems more difficult it s harder to isolate events of interest and it s more difficult to interpret what is displayed on the oscilloscope screen The 4000 Series addresses these challenges and repre sents the ultimate tool for engineers working with low speed serial buses such as C SPI RS 232 422 485 UART CAN LIN and FlexRay Bus Display Provides a higher level combined view of the individual signals clock data chip enable etc that make up your bus making it easy to identify where packets begin and end and identifying sub packet components such as address data identifier CRC etc Serial Triggering Trigger on packet content such as start of packet specific addresses specific data content unique identifiers etc on popular low speed seral interfaces such as PC SPI RS 232 422 485 UART CAN LIN and FlexRay Bus Decoding Tired of having to visually inspect the waveform to count clocks determine if each bit is al ora 0 combine bits into bytes and deter mine the hex value Let the oscillo scope do it for you Once you ve set up a bus the oscilloscope will decode each packet on the bus and display the value in either hex binary decimal LIN and FlexRay only or ASCII RS 232 422 485 UART only in the bus waveform Event Table In addition to seeing decoded packet data on the bus wave form itself you ca
11. both setup time and hold time between clock and data present on any of the input channels Rise Fall Time Trigger on pulse edge rates that are faster or slower than specified Slope may be positive negative or either Video Trigger on line number all lines odd even or all fields on NTSC PAL and SECAM video signals 10 Extended Video optional Trigger on 480p 60 576p 50 720p 30 720p 50 720p 60 8751 60 1080i 50 1080i 60 1080p 24 1080p 24sF 1080p 25 1080p 30 1080p 50 1080p 60 and custom bi level and tri level sync video standards I2C Optional Trigger on Start Repeated Start Stop Missing ACK Address 7 or 10 bit Data or Address and Data on C buses up to 3 4 Mb s SPI Optional Trigger on SS Idle Time MOSI MISO or MOS and MISO on SPI buses up to 10 0 Mb s CAN Optional Trigger on Start of Frame Frame Type data remote error overload Identifier stan dard or extended Data Identifier and Data End of Frame Missing ACK or Bit Stuffing Errors on CAN signals up to 1 Mb s Data can be further specified to trigger on lt lt gt or a specific data value User adjustable sample point is set to 50 by default RS 232 422 485 UART Optional Trigger on Tx Start bit Rx start bit Tx end of packet Rx end of packet Tx data Rx data Tx Parity Error and Rx Parity Error LIN Optional Trigger on Sync Identifier Data Identifier and Data Wakeup Frame Sleep Frame or Erro
12. content Ee estpatn P6516 MSO Probe This unique probe design offers two eight channel pods Each channel ends with a new probe tip design that includes a recessed ground for simpli filed connection to the device under test This sleek new probe simplifies the process of connecting to the device under test The coax on the first channel of each pod is colored blue making it easy to identify The common ground uses an automotive style connector making it easy to create custom grounds for connecting to the device under test When connecting to Square pins the P6516 has an adapter that attaches to the probe head extending the probe ground flush with the probe tip so you can attach to a header The P6516 offers outstanding electrical characteristics applying only 3 pF of loading The Power to Solve Problems Quickly The Performance and Feature Set You Expect The 4000 Senes Digital Phosphor Oscilloscopes DPO deliver the performance you need to visualize even your most demanding signals Bandwidths range from 350 MHz to 1 GHz and with all models offering a minimum of 5x oversampling on all channels and sin x x interpolation stan dard you can be confident that even the fastest transient events will be captured and displayed accurately The standard 10 M record length on all channels enables you to capture long windows of signal activity while main taining fine timing resolution Digital Phosphor Oscilloscopes gt
13. ease visit www tektronix com C TL eS aa Product s are manufactured in ISO registered facilities Product s complies with IEEE Standard 488 1 1987 RS 232 C and with Tektronix Standard Codes and Formats Copyright 2008 Tektronix All rights reserved Tektronix products are covered by U S and foreign patents issued and pending Information in this publication supersedes that in all previously published material Specification and price change privileges reserved TEKTRONIX and 43 Requires TekVPI to TekProbe BNC adapter TPA BNC TEK are registered trademarks of Tektronix Inc All other trade names referenced are the service marks trademarks or registered trademarks of their respective companies 04 08 HB WOW 3GW 20156 2 testpath Test Equipment Actessories
14. es and is available for a 30 day trial period standard with each instrument OpenChoice Desktop Enables fast and easy communication between a Windows PC and the 4000 Series via USB or LAN Transfer and save settings waveforms measurements and screen images IVI Driver Provides a standard instrument programming interface for common applications such as LabVIEW LabWindows CVI Microsoft NET and MATLAB Display Characteristics DisplayType 10 4 in 264mm liquid crystal TFT color display DisplayResolution 1 024 horizontal x 768 vertical pixels XGA Waveform Styles Vectors Dots Variable Persistence Infinite Persistence Graticules Full Grid Cross Hair Frame IRE and mV Format YT and simultaneous XY YT Waveform Capture Rate Up to 50 000 wfms sec Input Output Ports CompactFlash Drive Front panel access Type 1 USB2 0 Full Speed Host Port Supports USB mass storage devices printers and keyboard Two ports available on rear panel and one on front panel USB 2 0 High Speed Device Port Rear panel connector allows for control of oscilloscope via USBTMC or GPIB with a TEK USB 488 LAN Port RJ 45 connector supports 10 100Base T XGA Video Port DB 15 female connector connect to show the oscilloscope display on an external monitor or projector Auxiliary Input Front panel BNC connector Input Impedance 1M Max input 250 V RMS with peaks 400 V Probe Compensator Output Front panel pi
15. inimum Detectable 1 5 ns Pulse Width Channel to Channel Skew 60 ps typical Trigger System Main Trigger Modes Auto Normal and Single Trigger Coupling DC HF reject attenuates gt 50 kHz LF reject attenuates lt 50 kHz noise reject reduces sensitivity Trigger Holdoff Range 20 ns to 8 s Sensitivity Internal DC Coupled 0 4 div DC to 50 MHz increasing to 1 div at rated bandwidth External Auxiliary Input 200 mV from DC to 50 MHz increasing to 500 mV at 250 MHz Trigger Level Range Any Channel 8 divisions from center of screen External auxiliary input 8V Trigger Modes Edge Positive or negative slope on any channel or front panel auxiliary input Coupling includes DC HF reject LF reject and noise reject Sequence B trigger Trigger Delay by Time 4 ns to 8 s Or Trigger Delay by Events 1 to 9 999 999 events Pulse Width Trigger on width of positive or nega tive pulses that are gt lt or a specified period of time Runt Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again Logic Trigger when any logical pattern of channels goes false or stays true for specified period of time Any input can be used as a clock to look for the pattern on a clock edge Pattern AND OR NAND NOR specified for all analog and digital input chan nels defined as High Low or Don t Care Setup and Hold Trigger on violations of
16. ment Options Power Plug Options Opt AO North America Opt Al Universal Euro Opt A2 United Kingdom Opt A3 Australia Opt A5 Switzerland Opt A6 J apan Opt A10 China Opt A11 India Opt A99 No power cord or AC adapter Language Options Opt LO English manual Opt L1 French manual Opt L2 Italian manual Opt L3 German manual Opt L4 Spanish manual Opt L5 J apanese manual Opt L6 Portuguese manual Opt L7 Simplified Chinese manual Opt L8 Standard Chinese manual Opt L9 Korean manual Opt L10 Russian manual Opt L99 No manual Service Options 2 Opt C3 Calibration Service 3 years Opt C5 Calibration Service 5 years Opt CA1 Provides a single calibration event or coverage for the designated calibration interval whichever comes first Opt D1 Calibration Data Report Opt D3 Calibration Data Report 3 years with Opt C3 Opt D5 Calibration Data Report 5 Years with Opt C5 Opt R5 Repair Service 5 years including warranty Recommended Probes TAP1500 1 5 GHz TekVPI active probe TDP0500 500 MHz TekVPI 42 V differential probe TDP1000 1 GHz TekVPI 42 V differential probe TCP0030 120 MHz TekVP 30 Ampere AC DC current probe TCP0150 20 MHz TekVP 150 Ampere AC DC Current probe TCPA300 400 3 Current measurement systems P6246 400 MHz differential probe P6247 1 0 GHz differential probe
17. n view all captured packets in a tabular view much like you would see on a logic analyzer Packets are timestamped and listed consecu tively with columns for each component Address Data etc ks in m oa a rm I immm CE FE MEH FF m i Ln Packet decode table showing decoded Identifier DLC Data and CRC for every CAN packet in a long acquisition Search Serial triggering is very useful for isolating the event of interest but once you ve captured it and need to analyze the surrounding data what do you do In the past you had to manu ally scroll through the waveform counting and converting bits and looking for what caused the event With the 4000 Series you can have the oscilloscope search through the acquired data for user defined criteria including senal packet content Each occurrence is highlighted by a search mark Rapid navigation between marks IS aS Simple as pressing the Previous lt and Next gt buttons on the front panel Bat gg estpath Mixed Signal Design and Analysis MSO4000 As an embedded design engineer you are faced with the challenge of ever increasing system complexity A typical embedded design may incorporate various analog signals high and low Speed senal digital communication and microprocessor buses just to name a few Serial protocols such as IC and SPI are used frequently for chip to chip communication but parallel buses are still
18. nd a logic probe acces sory kit 020 2662 00 Application Modules DPO4EMBD Embedded Serial Triggering and Analysis Module Enables triggering on packet level information on C and SPI buses as well as analyt ical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with timestamp information DPO4COMP Computer Serial Triggering and Analysis Module Enables triggering on packet level information on RS 232 422 485 UART buses as well as analytical tools such as digital views of the Signal bus views packet decoding search tools and packet decode tables with timestamp information DPO4AUTO Automotive Serial Triggering and Analysis Module Enables triggering on packet level information on CAN and LIN buses as well as analyt ical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with timestamp information DPO4AUTOMAX Extended Automotive Serial Triggering and Analysis Module Enables triggering on packet level information on CAN LIN and FlexRay buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time Stamp information DPO4VID HDTV and Custom non standard Video Triggering Module es testpath Test Equipment Acoessores Digital Phosphor Oscilloscopes gt Tektronix 4000 Family e DPO4000 Series e MSO4000 Series Instru
19. niVu which acquires 10 000 points at up to 16 5 GS s 60 6 ps resolution Both main and MagniVu waveforms are acquired on every trigger and can be Switched between at any time running or stopped MagniVu provides close to ten times finer timing resolution than any other MSO on the market instilling confidence when making critical timing measurements on digital waveforms ae testpath Digital Phosphor Oscilloscopes gt Tektronix 4000 Family e DPO4000 Series e MSO4000 Series Serial Triggering and Analysis One of the most common applications requiring long record length is serial data analysis in embedded system design Embedded systems are literally everywhere They can contain many different types of devices including microprocessors microcontrollers DSPs RAM EPROMs FPGAs ADCs DACs and I O These various devices have traditionally communicated with each other and the outside word using wide parallel buses Today however more and more embedded systems are replacing these wide parallel buses with serial buses due to lower board Space requirements fewer pins lower power embedded clocks differential Signaling for better noise immunity and most importantly lower cost In addi tion there s a large supply of off the Shelf building block components from reputable manufacturers enabling rapid design development While serial buses have a large number of benefits they also present significant challenges th
20. ns Amplitude 2 5 V Frequency 1 kHz Trigger Out Rear panel BNC connector provides a positive polarity pulse when the oscilloscope triggers Kensington Lock Rear panel security slot connects to standard Kensington lock Digital Phosphor Oscilloscopes gt Tektronix 4000 Family e DPO4000 Series e MSO4000 Series PowerSource Power Source Voltage 100 to 240 V 10 PowerSource Frequency 47 to 66 Hz 90 to 264 V 360 to 440 Hz 100 to 132 V Power Consumption 250 W maximum Physical Characteristics Dimensions mm in Height 229 9 0 Width 439 li Depth 37 5 4 Weight kg Ibs Net 5 11 Shipping 9 5 OD Rackmount Configuration BU Cooling Clearance 2 in 51 mm required on left Side and rear of instrument General Characteristics Environmental Temperature Operating 0 C to 50 C Non operating 20 C to 60 C Humidity Operating High 40 C to 50 C 10 to 60 Relative Humidity Low 0 C to 40 C 10 to 90 Relative Humidity Non operating High 40 C to 60 C 5 to 60 Relative Humidity Low 0 C to 40 C 5 to 90 Relative Humidity Altitude Operating 3 000 meters 9 843 feet Non operating 12 000 meters 39 370 feet Random Vibration Operating 0 31 Gus from 5 to 500 Hz 10 minutes each axis 3 axes 30 minutes total Non operating 2 46 Grus from 5 to 500 Hz 10 minutes each axis 3 axes 30 minutes total Regulatory Electromagnetic Compatibility 8
21. ogic analyzer Standards supported include IC SPI CAN LIN FlexRay and RS 232 422 485 UART Analyze up to two buses on the DPO4000 and four on the MSO4000 at the same time Parallel is only available on MSO models 6 Stunning Display The 4000 Series boasts a large high resolution display 10 4 in 264 mm and 1 024x768 resolution XGA Test Equipment Accessories Digital Phosphor Oscilloscopes gt Tektronix 4000 Family e DPO4000 Series e MSO4000 Series ae Only 5 4 in Deep Despite the impressive performance huge display and knob per channel controls the 4000 Series is only 5 4 in deep Saving you valuable space on your test bench 7 Mass Storage Use the front panel USB and 8 Vertical Controls Knob per channel vertical 9 TekVPI TekVPI probe interface provides for CompactFlash ports for simple and convenient controls provide simple and intuitive operation No direct connect current probes intuitive comp box Storage of screenshots waveform data and oscillo longer do you need to share one set of vertical controls remote control of probe settings and scope setups Two more USB host ports are avail controls across all four channels smarter communication between the oscilloscope able on the rear panel for peripheral connections and the probe as well as a USB device port for instrument control using USBTMC as estpath Be Equipment Accessories Digital Phosphor Oscilloscopes gt Tektronix 400
22. ology provides finer timing resolution Per channel threshold settings Multi channel setup and hold triggering Next generation digital waveform display Applications Embedded design and debug Mixed signal design and debug Investigation of transient phenomena Power measurements Video design and debug Automotive electronics testpatn Test Equioment Accessories Digital Phosphor Oscilloscopes gt Tektronix 4000 Family e DPO4000 Series e MSO4000 Series z ei Wave Inspector controls Wave Inspector Navigation Imagine trying to efficiently use the Internet if search engines such as Google and Yahoo didn t exist Web browser features such as Favorites and Links didn t exist or Internet Service Providers like AOL or MSN weren t around Now you know how most modern oscilloscope users feel when trying to actually use the long record length in their digital oscilloscope Record length one of the key specifica tions of an oscilloscope is the number of samples it can digitize and store ina Single acquisition The longer the record length the longer the time window you can capture with high timing resolution high sample rate The first digital oscilloscopes could Capture and store only 500 points which made tt very difficult to acquire all relevant information around the event being investigated Over the years oscilloscope vendors have provided longer and longer record lengths to meet ma
23. r the zoom box moves Pan direction is changed by Simply turning the knob the other way No longer do you need to navigate through multiple menus to adjust your Zoom view S P P6516 Mixed Signal Oscilloscope probe Play Pause A dedicated play pause button on the front panel scrolls the waveform across the display automati cally while you look for anomalies or an event of interest Playback speed and direction are controlled using the intuitive pan knob Once again turning the knob further makes the waveform scroll faster and changing direction is as Simple as tuming the knob the other way User Marks See something inter esting on your waveform Press the Set Mark button on the front panel to leave one or more bookmarks on the waveform Navigating between marks IS aS Simple as pressing the Previous and Next buttons on the front panel Search Marks Don t want to take the time to inspect the entire acquisition to find the event you re looking for The 4000 Senes features a robust wave form search feature that allows you to search through your long acquisition based on user defined criteria All occurrences of the event are high lighted with search marks and are easily navigated to using the front panel Previous lt and Next buttons Search types include edge pulse width runt logic setup and hold rise fall time and parallel 4C SPI RS 232 422 485 UART CAN LIN and FlexRay packet
24. rket demands for long capture windows with high resolution to the point that most mid range oscillo scopes either come standard with or can be optionally upgraded to multi mega point record lengths These mega point record lengths often repre sent thousands of screens worth of Signal activity While standard record P Wave Inspector controls provide unprece dented efficiency in viewing navigating and analyzing waveform data lengths have increased greatly over the years and can now Satisfy the vast majority of applications in the market place tools for effectively and efficiently viewing navigating and analyzing long record length acquisitions have been sorely neglected until now The Tektronix 4000 Series redefines expectations for working with long record lengths with the following inno vative Wave Inspector controls Zoom Pan A dedicated two tier front panel knob provides intuitive control of both zooming and panning The inner knob adjusts the zoom factor or zoom scale turning it clockwise activates zoom and goes to progres sively higher zoom factors while turning it counter clockwise results in lower zoom factors and eventually turning zoom off The outer knob pans the zoom box across the waveform to quickly get to the portion of the wave form you are interested in The outer knob also utilizes force feedback to determine how fast to pan on the waveform The farther you turn the outer knob the faste
25. rs such as Sync Parity or Checksum Errors FlexRay Optional Trigger on Start of Frame Type of Frame Normal Payload Null Sync Startup Identifier Cycle Count Complete Header Field Data Identifier and Data End of Frame or Errors such as Header CRC Trailer CRC Null Frame Sync Frame or Startup Frame Errors Parallel available on MSO models only Trigger on a parallel bus data value Ac quisition Modes Sample Acquires sampled values Peak Detect Captures glitches as narrow as 200 ps at all sweep speeds Averaging From 2 to 512 waveforms included in average Envelope Min max envelope reflecting Peak Detect data over multiple acquisitions Hi Res Real time boxcar averaging reduces random noise and increases vertical resolution Roll Scrolls waveforms right to left across screen at sweep speeds slower than or equal to 40ms div Waveform Measurements Cursors Waveform and Screen Automatic Measurements 29 of which up to eight can be displayed on screen at any one time Measurements include Period Frequency Delay Rise Time Fall Time Positive Duty Cycle Negative Duty Cycle Positive Pulse Width Negative Pulse Width Burst Width Phase Positive Overshoot Negative Overshoot Peak to Peak Amplitude High Low Max Min Mean Cycle Mean RMS Cycle RMS Positive Pulse Count Negative Pulse Count Rising Edge Count Falling Edge Count Area and Cycle Area Measurement Statistics Mean Min Max
26. t ae P Viewing an NTSC video signal Notice the intensity graded view provided by the DPO s ability to represent time amplitude and distribution of amplitude over time P Fast waveform capture rate maximizes the probability of capturing elusive glitches and other infrequent events E ed gt testpath Digital Phosphor Oscilloscopes gt Tektronix 4000 Family e DPO4000 Series e MSO4000 Series gt Characteristics Vertical System MSO4032 DPO4034 DPO4054 DPO4104 Analog Channels MSO4034 MSO4054 MSO4104 Inout Channels 2 4 4 4 Analog Bandwidth 3 dB 350 MHz 350 MHz 500 MHz 1 GHz 5 mV div to 1 V div Calculated Rise Time lns l ns 700 ps 350 ps 5 mV div typical Hardware Bandwidth Limits 20 MHz or 250 MHz Input Coupling AC DC GND Inout Impedance 1M Q 1 50 Q 1 Input Sensitivity 1 MQ 1 mV div to 10 V div Input Sensitivity 50 Q 1 mV div to 1 V div Vertical Resolution 8 bits 11 bits with Hi Res Max Input Voltage 1 MQ 250 Vays with peaks lt 400 V Max Input Voltage 50 Q 5 Vans with peaks lt 20 V DC Gain Accuracy 1 5 with offset set to 0 V Offset Range 1 MQ 50 Q 1 mV div to 50 mV div 1 V 1V 50 5 mV div to 99 5 mV div 0 5 V 0 5V 100 mV div to 500 mV div 10 V 10V 505 mV div to 995 mV div 5 5 V 1 V div to 5 V div 100 V 5 V 5 05 V div to 10 V div 50 V NA Channel to channel Isolation gt 100 1 at lt 100 MHz and 30 1 at gt 100 MHz up to the rated bandwidth for any two channels having equal
27. the waveform Navigating your Glcounts waveform has never been easier ETTA counta ETETE BcouNTa r CERU NTI ig pa l ARAHI N Marks Want to mark your waveform for future reference or for quick navigation between events of interest Simply press the Set Mark button to Fico place bookmarks on your waveform Use the next and previous buttons to navigate through user marks and search generated marks Pecounra rr Feon mema ije i i balnis BDis 50 E Thing meiatutine zonna etd f ey Qe Am mi WW Search Tired of turning the horizontal position knob endlessly on your current scope to find the event you re looking for Use the 4000 s powerful Search feature to find and mark all occurrences of an event based on user specified criteria Search types include edge pulse width runt logic multi channel setup and hold rise fall time and C SPI CAN LIN FlexRay and RS 232 422 485 UART packet content p 2 eat m Miri 2 or 4 Analog Channels and 16 Digital Channels View and trigger on up to 20 time correlated signals on the same display 16 Digital Channels are only available on MSO models Parallel and Serial Buses Trigger on parallel or serial packet level content view acquired data as a bus with all data decoded into hex binary or ASCII search through acquisitions for specific content and even view all decoded data in a tabular format much like you would see on a l
28. used in many applications Microprocessors FPGAs Analog to Digital Converters ADCs and Digital to Analog Converters DACs are all examples of ICs that present unique measurement challenges in today s embedded designs The MSO4000 Series Mixed Signal Oscilloscopes offer the addition of 16 digital channels These channels are tightly integrated into the oscilloscope s user interface Simplifying operation and making tt possible to solve mixed signal issues more easily P White edges indicate additional information is available by zooming in Next Generation Digital Waveform Display In a continued effort to make mixed Signal oscilloscopes easy to use the MSO4000 Series has redefined the way you view digital waveforms One common problem shared by both logic analyzers and mixed signal oscillo Scopes is determining if data is a one or a zero when zoomed in far enough that the digital trace stays flat all the way across the display The MSO4000 has color coded the digital traces displaying ones in green and zeros in blue The MSO4000 has multiple transition detection hardware When the system detects multiple transitions the user will see a white edge on the display White edges indicate that more information is available by zooming in or acquiring at faster Sampling rates In most cases zooming in will reveal the pulse that was not viewable with the previous Settings If the white edge is still present after zooming in

Download Pdf Manuals