Home
20SYST016 E1 User Manual
Contents
1. As an option MEN can also provide the rack for wall mounting i e on a vertical surface The cooling fins will then fit the mounting orientation Please contact MEN S sales team for further information In any case the surface where the rack is mounted on must provide for sufficient airflow to the cooling fins Mounting the rack onto a closed surface e g a table will not be sufficient MEN Mikro Elektronik GmbH 20 20SYSTO16 E1 2010 01 12 Getting Started 2 2 3 Thermal Considerations The inner shape of each CCA framed board inside the rack is unique to the cooling requirements of this board accommodating specific hot spots that need thermal contact with the CCA frame Those frames are mounted with wedge lock connectors for reliable thermal coupling transferring heat efficiently from the CPU to the frame and housing of the CCA rack The maximum temperature inside the rack is 85 C The maximum operating temperature of the entire rack i e the temperature on the rack s surface is 70 C with an allowed 85 C for maximum 10 minutes This specification conforms with the EN 50155 railway standard The total thermal resistance Ry of the CCA rack is 0 4 C W allowing system designers to calculate the performance of their applications according to the following formula AT Tinternal 7 Tambient Py Rin As an example this formula would dictate a maximum electrical power of 37 5 W to be installed in a CCA fr
2. 1 min 2 min 4 min 8 min oy BR ow DV oO 16 min 3 1 4 Fuse Protection The DC DC converter of the PSU is protected by a fuse This fuse is not intended to be exchanged by the customer Your warranty for the CCA rack will cease if you exchange the fuse on your own Please send your rack and PSU to MEN for repair if a fuse blows e Current rating 5 A e Type fast e Size 4 5 x 12 1 mm MEN part number 5675 0009 MEN Mikro Elektronik GmbH 23 20SYSTO016 E1 2010 01 12 Functional Description 3 2 I O Outer Connectors Both the front and rear I O of the boards inside the CCA rack can be made available on three MIL C 38999 connectors located at the back plate Since the CCA rack is completely closed during operation these connectors are the only way of linking up peripherals The connectors all have different types and pin counts totaling 59 user I O pins Figure 6 Outer connectors at rear panel of CCA rack X4 N 1 Power Supply om NE E 2 TT Table 4 Pin layout and types of outer connectors X1 X3 X1 Operational 1 X2 Operational 2 X3 Maintenance 19 pins 18 pins 22 pins The exact functional pin out depends on the cards implemented in the CCA rack It is completely customizable See also Chapter 1 3 Signal Routing and Wiring on page 13 Connector types X1 19 pin X2 18 pin X3 22 pin e D38999 24FD19PN e D38999 24FD18PA e D38999 24FC35
3. 20SYSTO16 E1 2010 01 12 CPCI Rack Single Euro with Conduction Cooling Configuration example User Manual man mikro elektronik gmbh n rnberg CPCI Rack Single Euro with Conduction Cooling CPCI Rack Single Euro with Conduction Cooling This enclosure for CompactPCI cards in 3U format allows to use standard boards that were designed for ventilated systems even in an environment which needs conductive cooling To do this all critical components are directly coupled to the housing to divert waste heat to the exterior wall This reduces the costs involved in the higher overhead of conduction cooling to the housing and no PCB space is lost on the boards for this cooling method This extremely robust enclosure is hermetically sealed against impacts from outside offers high vibration and shock resistance through the use of wedge locks as well as special connector types such as MIL C 38999 The standard front connectors of the boards are wired to four MIL C 38999 connectors three I O connectors and one power supply connector at the rear side of the system inside the housing Both front and rear I O can be made available on these connectors and the pin out is always customized The standard CompactPCI boards are fitted into a special CCA frame conduction cooled assembly and inserted into the system The system provides three CompactPCI slots for one CPU board with a side card and one I O board a
4. 7 MEN Mikro Elektronik GmbH 10 20SYSTO16 E1 2010 01 12 Figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Tables Table 1 Table 2 Table 3 Table 4 MEN Mikro Elektronik GmbH 20SYSTO16 E1 2010 01 12 Diagram of the CCA rack excluding power supply unit 12 Signal routing and wiring of interfaces inside the CCA rack 13 Mounting holes at the bottom plate of the CCA rack 19 Dimensions of the bottom plate of the CCA rack 19 Mounting orientations of standard CCA rack version 20 Outer connectors at rear panel of CCA rack 24 Backplane connectors ss ss ssssosissssasseksiskros teens 25 Protective vent on the front plate of the CCA rack 26 Label giving the board s article number revision and serial number 27 Pin assignment of X4 Power Supply outer connector 22 Signal mnemonics of X4 Power Supply outer connector 22 Power supply standby delay timing values 23 Pin layout and types of outer connectors X1 X3 lusu 24 encae m System Overview 1 System Overview 1 1 Basic Principle The CCA rack is designed to support single board computers SBCs in normal 3U CompactPCI format The rack s backplane connectors adhere to the CompactPCI standard but the mounting spacing between these connector
5. E sss 14 2 1 1 Installing Boards in the Rack 0 15 2 1 2 Installing Operating System Software 18 2 1 3 Installing Driver SOI Wale iu be iE pU EE 18 2 2 Installing the Rack into an Application Environment 19 2 2 Dimensions and Mounting Holes 19 22 2 JRackOnentalion o9 3259 92d woche d dps od 20 2 2 3 The rmalConsiderations s s ss stanekrstas ent 21 3 Functional Description 69 85 00 50 5 5 sie 600 hm SR ine Se wre mie a RUE 22 3 PowerSupply s 400 s ss sui sca tartis 9 e hr a OSES ee 22 all Outer COBnectOE 1 2 1252 34 munda hoek nee oka neka 22 3 L2 Temperature Sensor s 243 sud 2446400 2540044 P Sees 29 3 1 3 Digital Input and Standby s s 23 S L Puse Proleetlon sss nion EASA skon sda 23 3 2 VO Outer Connectors soe sa uun aka duno e deba ekagas 24 33 Backplane sesa sk zus eN nko IGS is BIS 25 So vCompactPCl Bus 259a a Ua bub kun boc bad dene 25 3 3 2 Side Card Slot and Peripheral Slot 25 3 3 3 Connection between CompactPCI and Power Supply 25 3 4 Protective Vent sss br oda Rr n des LIAS esas kda os 26 4 ADDENdiX s rh L sess RT LS 3 33383 27 4 Literature and Web Resources 00 0 eee 27 4 2 Finding out the Product s Article Number Revision and Serial NUMDEF 553 2520980 SAGNE AKOR E E SU RC ROO dep REO 2
6. FB99SN receptacle MEN offers a set of suitable mating connectors for all four outer connectors of the ee CCA rack Please see MEN s website for ordering information 3 1 2 Temperature Sensor The power supply provides an integrated temperature sensor for the detection of overtemperature conditions that could cause a destruction of the power supply The temperature sensor is configurable within an overtemperature range of 50 C to 90 C The temperature limit can be set using the PSU driver software available for download on MEN s website MEN Mikro Elektronik GmbH 22 20SYSTO016 E1 2010 01 12 Functional Description 3 1 3 Digital Input and Standby The power supply provides one digital input PS Enable to enable disable the output voltages The digital input is connected to a control line that provides a controlled shut down of the CCA rack system The power supply generates a maximum standby power of 0 5 W The standby condition is defined as follows Input voltage U 24 V Digital input low 0 V e Output voltage 5 V 0 V disabled Output voltage 3 3 V 0 V disabled The power supply provides a programmable delay time between the falling edge of the digital input and the output voltages being switched off The mode can be set e using the PSU driver software available for download on MEN s website Table 3 Power supply standby delay timing values Mode Standby Delay No standby delay default
7. PN plug plug plug Mating connector Mating connector Mating connector D38999 26FD19SN D38999 26FD18SA D38999 26FC35SN receptacle receptacle receptacle MEN offers a set of suitable mating connectors for all four outer connectors of the ee CCA rack Please see MEN s website for ordering information Ask our sales team for tailor made custom configuration options MEN Mikro Elektronik GmbH 24 20SYSTO016 E1 2010 01 12 Functional Description 3 3 Backplane The backplane basically includes one CompactPCI system slot and two peripheral slots The peripheral slot next to the system slot is designed to support also side cards for the CPU The card plugged into this slot must share the front plate with the CPU The distance between the two slots complies with a standard CompactPCI backplane 4 HP slot whereas the distance between the other slots is greater to accommodate 3U cards with an individual CCA frame 5 HP slots The backplane also provides a slot for a 3U card power supply unit using a standard H15 receptacle connector Only the CompactPCI system slot has a J2 connection to route rear I O signals to the rear I O board and from there to the outer connectors The peripheral slots do not support rear I O Figure 7 Backplane connectors cPCI Peripheral Slot CCA distance cPCI Side Card Peripheral Slot Common i front plate cPCI distance I J2RIO cPCI System
8. Slot CCA distance PSU Slot 3 3 1 CompactPCI Bus The CCA rack supports 32 bit 33 MHz CompactPCI compliant with CompactPCI specification PICMG 2 0 Rev 3 0 The backplane provides a CompactPCI reset 3 3 2 Side Card Slot and Peripheral Slot Both the side card slot slot 2 and the peripheral slot slot 3 are ordinary CompactPCI peripheral slots However the distance between the system slot and side card slot is smaller than usual A side card is a normal CompactPCI form factor board but is directly coupled to the system slot and shares a front panel with the CPU This means in turn that it is mechanically and electrically possible to plug any 4 HP peripheral card into slot 2 of the CCA rack as long as it forms a unit with the CPU board with a common front panel MEN can provide a suitable CPU and peripheral board solution together with the CCA adaption on request Please contact MEN s sales team for further information 3 3 3 Connection between CompactPCI and Power Supply The backplane provides an SMB connection between the CompactPCI slots and the power supply slot This allows the driver software to access and configure the PSU MEN Mikro Elektronik GmbH 25 20SYST016 E1 2010 01 12 Functional Description 34 Protective Vent The protective vent at the side of the enclosure provides an effective barrier from dust and dirt and still allows the sealed housing to breathe with changing environment
9. al conditions This prevents pressure from building up and damaging enclosure seals exposing sensitive components to water and debris Figure 8 Protective vent on the front plate of the CCA rack MEN Mikro Elektronik GmbH 26 20SYSTO16 E1 2010 01 12 Appendix 4 Appendix wy 4 1 Literature and Web Resources e CCA rack data sheet with up to date information and documentation www men de products 0701 0054 html 4 2 Finding out the Product s Article Number Revision and Serial Number MEN user documentation may describe several different models and or design revisions of the CCA rack You can find information on the article number the design revision and the serial number on a label attached to the chassis Article number Gives the product s family and model This is also MEN s ordering number To be complete it must have 9 characters Revision number Gives the design revision of the product Serial number Unique identification assigned during production If you need support you should communicate these numbers to MEN Figure 9 Label giving the board s article number revision and serial number man p mikro elektronik es gmbh n rnberg Madein Article No 0701 0054 Germany Serial No 000001 O Rev No 00 00 00 MEN Mikro Elektronik GmbH 27 20SYSTO016 E1 2010 01 12
10. ame with a maximum allowable temperature of 85 C and an ambient temperature of 70 C Pon 2AT Rg 15 C 0 4 C W 37 5 W Likewise given an installed electrical power of 22 W and an outside temperature of 60 C the component operating temperature could be calculated as 68 8 C Tatermaj Py Rin Tambien 22 W 0 4 C W 60 C 68 8 C It heavily depends on the thermal performance of your boards on whether you can implement the desired configuration with MEN s CCA rack If you have any questions or problems regarding thermal behavior please contact MEN MEN Mikro Elektronik GmbH 21 20SYSTO016 E1 2010 01 12 Functional Description 3 Functional Description 3 1 Power Supply The CCA rack has its own power supply unit PSU The PSU supports a voltage range of 18 32 V and 35 W You can find driver software for the PSU power supply unit for download on Q6 MEN s website 3 1 1 Outer Connector Table 1 Pin assignment of X4 Power Supply outer connector A VCC B VCC C D GND E GND F G PS Enable Table 2 Signal mnemonics of X4 Power Supply outer connector Signal Direction Function GND Isolated ground PS Enable in Power Supply enable VCC in 24V nom supply voltage Minimum 18V 25 Maximum 32V 33 Protected against input voltage reversal by a fuse Connector types D38999 24FB99PN plug Mating connector D38999 26
11. eral devices and integration into a system It also provides additional information for special applications and configurations of the rack The manual does not include detailed information on individual components data sheets etc A list of literature is given in the appendix History Issue Comments Date P1 Preliminary issue 2009 12 23 E1 First released issue 2010 01 12 Conventions This sign marks important notes or warnings concerning proper functionality of the product described in this document You should read them in any case italics Folder file and function names are printed in italics bold Bold type is used for emphasis monospace A monospaced font type is used for hexadecimal numbers listings C function descriptions or wherever appropriate Hexadecimal numbers are preceded by Ox hyperlink Hyperlinks are printed in blue color The globe will show you where hyperlinks lead directly to the Internet so you can look for the latest information online IRQ Signal names followed by or preceded by a slash indicate that this signal is IRQ either active low or that it becomes active at a falling edge in out Signal directions in signal mnemonics tables generally refer to the corresponding board or component in meaning to the board or component out meaning coming from it Vertical lines on the outer margin signal technical changes to the previous issue of the document MEN Mikro Elekt
12. heral card slot slot 3 of the CCA rack Note The peripheral slot of the CCA rack is marked by a circle O on the back plane slot 3 M Use a 2 5 mm hexagon torque wrench to fasten the two wedge locks of every card that you have inserted into the rack You need to apply a turning moment torque of 0 8 Nm MEN Mikro Elektronik GmbH 17 20SYSTO16 E1 2010 01 12 e Getting Started Connect special board interfaces M If you need to wire e g front panel interfaces of the CCA framed boards to the rear panel and outer connectors of the rack you should do this now The rack leaves some space in between the outer and inner top plate to lead wires between the front and back areas like the power supply connection The above picture shows the view inside the rack from the top For a better view this example shows a placeholder for the rear I O board which is neces sary to make the connection from the CompactPCI backplane to the outer con nectors MI For better access to the outer connectors you can remove the back plate in the same way as the front plate The ten screws are arranged in the same way See page 15 When everything is connected you can power up the system to install and configure the software The user manuals of the individual boards usually include useful hints on first operation 2 1 2 Installing Operating System Software By standard no operating system is installed on the boards Please refe
13. ieved to be accurate as of the date of publication however no responsibility is assumed for inaccuracies MEN Mikro Elektronik accepts no liability for consequential or incidental damages arising from the use of its products and reserves the right to make changes on the products herein without notice to improve reliability function or design MEN Mikro Elektronik does not assume any liability arising out of the application or use of the products described in this document Copyright 2010 MEN Mikro Elektronik GmbH AlI rights reserved O Please recycle Germany France USA MEN Mikro Elektronik GmbH MEN Mikro Elektronik SA MEN Micro Inc Neuwieder StraBe 5 7 18 rue Ren Cassin 24 North Main Street 90411 Nuremberg ZA de la Chatelaine Ambler PA 19002 Phone 49 911 99 33 5 0 74240 Gaillard Phone 215 542 9575 Fax 49 911 99 33 5 901 E mail info men de www men de MEN Mikro Elektronik GmbH 20SYSTO16 E1 2010 01 12 Phone 33 0 450 955 312 Fax 33 0 450 955 211 E mail info men france fr www men france fr Fax 215 542 9577 E mail sales menmicro com www menmicro com Contents Contents l System OvervIGW sse is usi bis 980s eR PARU FIN SINON SDAS VIa 12 DI Basic Drnctplei4 ssp resa a ka sd babe ons renes 12 1 2 Layoutof the Rack 2 esce een 9 been s 12 13 Signal Routing and WUME iu sona sei e or er ped RS aks 13 2 Getting Started c sss vy vr HELP RESIS PPP 14 2 1 Contieuring the Rack 2121 2098 eroe ERST RET
14. nd e Holdup time according to EN50155 Class S2 MEN Mikro Elektronik GmbH 3 20SYSTO16 E1 2010 01 12 Technical Data Environmental Specifications Temperature range operation 40 C to 70 C with up to 85 C for 10 minutes according to class Tx EN50155 Thermal resistance 0 4 K W e Temperature range storage 40 85 C Relative humidity operation max 9596 non condensing Relative humidity storage max 9596 non condensing Shock according to EN 61373 Class B Vibration according to EN 61373 Class B Suited for MEN Boards e F50C e F11S ina special CCA version FI2N in a special CCA version F13 ina special CCA version e F14 in a special CCA version F15 ina special CCA version e F17 ina special CCA version e F18 in a special CCA version e F19P ina special CCA version MEN Mikro Elektronik GmbH 4 20SYSTO16 E1 2010 01 12 Diagram Xi x4 gt Operational 1 Power Supply Peripheral Slot O Side Card Slot X2 X3 Operational 2 Maintenance System Slot PSU Slot Rear Panel Backplane MEN Mikro Elektronik GmbH 5 20SYSTO16 E1 2010 01 12 Configuration Options Configuration Options Slots Different number type of slots requires change of mechanical dimensions VO e Individual signal routing to outer connecto
15. oard is located behind the backplane and is connected to the J2 connector of the system slot It brings the J2 I O signals to the outer connectors X1 to X3 at the rear panel The rear I O board can also contain interface circuits necessary to connect the rack to the application environment It is always customized to the application s requirements I O from the 3U boards front panels can be wired directly to the rear panel Figure 2 Signal routing and wiring of interfaces inside the CCA rack Rack internal wiring from card front Rear panel Rear I O board Inner top plate 3 Backplane panels to rear panel Front panel I O of 3U cards CCA framed peripheral card and system CPU CCA framed PSU card la MEN Mikro Elektronik GmbH 13 20SYSTO016 E1 2010 01 12 Getting Started 2 Getting Started This chapter gives some hints for first installation in a system 2 1 Configuring the Rack The configuration of the CCA rack needs some advance planning Being very compact the rack provides only three CompactPCI card slots Because they are located behind the backplane the signals of the J2 rear I O connector of the system slot card can more or less directly be led to the rear panel outer connectors which support 59 customizable pins on three connectors X1 to X3 The two additional peripheral side cards normally have only front panel I O This can also be led to the rack s outer connectors by wiring The rack s interio
16. r leaves enough space to safely lead wires between the inner and outer top plate Having led all necessary signals to the rear side of the rack you also need a rear I O board in between the CompactPCI backplane and back plate to adapt the signals to the outer connectors This is typically done by MEN according to the customer s requirements Other issues that you should consider in advance are the mechanical and thermal situation of your application Because of its cooling fins the standard rack can only be installed in horizontal orientation On the other hand not all board combinations may be possible because of the cards thermal performance For details on rack internal wiring see Chapter 1 3 Signal Routing and Wiring on page 13 e I O outer connectors see Chapter 3 2 I O Outer Connectors on page 24 rack orientation see Chapter 2 2 Installing the Rack into an Application Environ ment on page 19 thermal considerations see Chapter 2 2 3 Thermal Considerations on page 21 Ask our sales team for tailor made custom assembly and configuration options When you have your customized rack boards and software you can start implementing your system The following chapters give you the typical steps that are necessary Some or all of these steps may be taken by MEN depending on the customer s requirements MEN Mikro Elektronik GmbH 14 20SYSTO016 E1 2010 01 12 Getting Started 2 1 1 Installing Boards in
17. r to the respective manufacturers documentation on how to install operating system software You can find any software available on MEN s website 2 1 3 Installing Driver Software For a detailed description on how to install driver software please refer to the respective documentation You can find driver software for the PSU power supply unit for download on MEN s website MEN Mikro Elektronik GmbH 16 20SYSTO16 E1 2010 01 12 Getting Started 2 2 Installing the Rack into an Application Environment 2 2 1 Dimensions and Mounting Holes The rack s total dimensions are 200 mm x 350 mm x 145 mm The housing is made for sturdy screw mounting and provides six mounting holes at its bottom plate Figure 3 Mounting holes at the bottom plate of the CCA rack 297 00 se 2 amp e B e Su 2 e hej Z MEN Mikro Elektronik GmbH 19 20SYST016 E1 2010 01 12 Getting Started 2 2 2 Rack Orientation It generally depends on the application environment on how and where the CCA rack is mounted Because of the orientation of its cooling fins the standard rack can only be mounted on a horizontal surface as shown in the following figure Figure 5 Mounting orientations of standard CCA rack version Horizontal surface ENSIA Airflow through cooling fins 1o bd Mounting to vertical surfaces T is only possible with a special I rack configuration o o o
18. ronik GmbH 20SYSTO16 E1 2010 01 12 About this Document Legal Information MEN Mikro Elektronik reserves the right to make changes without further notice to any products herein MEN makes no warranty representation or guarantee regarding the suitability of its products for any particular purpose nor does MEN assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability including without limitation consequential or incidental damages Typical parameters can and do vary in different applications All operating parameters including Typicals must be validated for each customer application by customer s technical experts MEN does not convey any license under its patent rights nor the rights of others Unless agreed otherwise MEN products are not designed intended or authorized for use as components in systems intended for surgical implant into the body or other applications intended to support or sustain life or for any other application in which the failure of the MEN product could create a situation where personal injury or death may occur Should Buyer purchase or use MEN products for any such unintended or unauthorized application Buyer shall indemnify and hold MEN and its officers employees subsidiaries affiliates and distributors harmless against all claims costs damages and expenses and reasonable attorney fees arising out of directly or indirectl
19. rs e Individual CCA frame Connectors e Different outer connectors e g M12 PSU e Input voltage range 9 154V Mechanical e Wall mounting Please note that some of these options may only be available for large volumes Please ask our sales staff for more information For available standard configurations see online data sheet MEN Mikro Elektronik GmbH 6 20SYST016 E1 2010 01 12 Product Safety Product Safety A Electrostatic Discharge ESD Computer boards and components contain electrostatic sensitive devices Electrostatic discharge ESD can damage components To protect the board and other components against damage from static electricity you should follow some precautions whenever you work on your computer Power down and unplug your computer system when working on the inside Hold components by the edges and try not to touch the IC chips leads or cir cuitry Use a grounded wrist strap before handling computer components Place components on a grounded antistatic pad or on the bag that came with the component whenever the components are separated from the system Store the board only in its original ESD protected packaging Retain the original packaging in case you need to return the board to MEN for repair MEN Mikro Elektronik GmbH 7 20SYSTO016 E1 2010 01 12 About this Document About this Document A This user manual describes the hardware functions of the rack connection of periph
20. s is adjusted to accommodate the added thickness of so called CCA frames These Conduction Cooled Assembly frames can make a conduction cooled board out of almost any standard off the shelf CPU or I O board Each unique board processor combination is matched to a customized frame system with a tailor made heat sink designed to transfer heat efficiently from the CPU to the frame and housing of the convection cooled rack enclosure This has cost and availability benefits and there is no need to sacrifice board space for conduction cooling Ask our sales team for tailor made CCA frame boards based on standard 3U CompactPCI 1 2 Layout of the Rack Figure 1 Diagram of the CCA rack excluding power supply unit Inner top plate PA l Z Top plate Back plate A Backplane Front plate rear panel PA gt cPCI Mf j connectors Rear I O board Power supply B A i connector LT yy rp t ded Protective vent U Bottom plate XI x4 Operational 1 Power Supply Peripheral Slot with mounting holes O Side Card Slot x2 X3 Operational 2 Maintenance System Slot PSU Slot Rear Panel Backplane MEN Mikro Elektronik GmbH 12 20SYSTO16 E1 2010 01 12 System Overview 1 3 Signal Routing and Wiring The following figure by means of the red arrows shows how signals are routed and can be wired inside the CCA rack A rear I O b
21. s well as a PSU slot with an H15 connector The distance between the slots on the backplane is greater than on standard backplanes The thermal resistance is 0 4 Kelvin Watt and the temperature class Tx for 40 W maximum performance for boards with an operating temperature of 40 to 85 C The enclosure is compliant with IP65 for protection against dust and humidity The system is suited for MEN boards F11S F12N F13 F14 F15 F17 F18 F19P and F50C MEN Mikro Elektronik GmbH 2 20SYSTO016 E1 2010 01 12 Technical Data Technical Data General System Characteristics 3 slots for 3U Eurocard boards in CCA frame Middle slot right of the system slot designed for a side card connected to the CPU board Conduction cooled Mechanical Specifications 3U card horizontal Dimensions 200 mm x 350 mm x 145 mm Weight 4500g P65 compliant Connectors 4 MIL C 38999 connectors X1 X4 e X1 X3 for customized I O 59 usable I O pins X4 for power supply CompactPCI Backplane e Compliance with CompactPCI Spec 2 0 Rev 2 1 and IEC 61 076 4 101 con nectors e 3 slot CPU system slot Side card slot Peripheral slot e System slot on the left Power Supply PSU 3U CCA Input 24VDC nominal 18 32V e Output 5V 3 3V 35W Robust internal connection to rear panel outer connector X4 SMBus External I Os for key function Overtemperature shutdown 50 90 C adjustable by SMBus comma
22. the Rack Perform the following steps to install a CompactPCI CCA board Open the housing Mi Remove the front plate by unscrewing the 10 screws highlighted in the picture oO MI If you need to do some rack internal wiring with your boards you should also remove the top plate by unscrewing the 14 screws highlighted in the picture MEN Mikro Elektronik GmbH 15 20SYSTO16 E1 2010 01 12 Getting Started Mi There are sealing rubber bands in grooves below the top plate Take care not to damage or loose them and to put them back in place when you re mount the top plate Insert CCA compatible CompactPCI boards MI Insert your CPU board into the system slot of the CCA rack Take care not to damage the power supply wires and make sure to properly align the Compact PCI connectors Note The system slot of the CCA rack is marked by a A triangle on the back plane slot 1 Note If you have an MEN CPU the board may already include a side card directly connected to the CPU The slot to the right of the system slot slot 2 is specially designed for side cards MEN Mikro Elektronik GmbH 16 20SYSTO16 E1 2010 01 12 Getting Started Mi Push the board firmly into the rack until the front plate of the board s CCA frame evenly aligns with the front plate of the PSU unit To do this you need to fasten the front panel screws of the board to the guide rails Mi If applicable insert a peripheral card into the perip
23. y any claim of personal injury or death associated with such unintended or unauthorized use even if such claim alleges that MEN was negligent regarding the design or manufacture of the part Unless agreed otherwise the products of MEN Mikro Elektronik are not suited for use in nuclear reactors or for application in medical appliances used for therapeutical purposes Application of MEN products in such plants is only possible after the user has precisely specified the operation environment and after MEN Mikro Elektronik has consequently adapted and released the product ESM ESMini MDISTM MDIS4 MENMONTM M Module M Modules SA AdapterTM SA AdaptersTM UBox USM and the MBIOS logo are trademarks of MEN Mikro Elektronik GmbH PC MIPQ is a registered trademark of MEN Micro Inc and SBS Technologies Inc MEN Mikro Elektronike ESMexpress MIPIOS and the MEN logo are registered trademarks of MEN Mikro Elektronik GmbH All other products or services mentioned in this publication are identified by the trademarks service marks or product names as designated by the companies who market those products The trademarks and registered trademarks are held by the companies producing them Inquiries concerning such trademarks should be made directly to those companies All other brand or product names are trademarks or registered trademarks of their respective holders Information in this document has been carefully checked and is bel
Download Pdf Manuals