Home

SPPL-UR-S-Specification, Installation and Operation

image

Contents

1. Contents Sal ESS SUS lo a U Ee E wot eaoeeane auen cae neoanesa dade taanesiatvatsecyesapsansieaetaay 1 RECOMMENda ONSE reat snitte rE eanan Enr E EEE Ea E EESO EEA NENESE 3 PSS ONS HOMME ar E E N A A ES E E E E E E E E AT 3 CO a a tee acct cyte E actande eeceeaesss toeos soot ese aac soceanee 3 Fe UM te ee cee ence rd E A AT EEE EA EIN E E actos ecra en T cab sects E T E 3 Referenced Australian StandardS ccictnisa es isnnsaair aaa tinadcaasnataadiontcntsce deuiivaial apinnid entiunslnddatinausae wife Madnaaeanwianeslubainin 4 Slab Urinal SCAN AUOI acec nrcntnasn icrisnadnswnimeactnndiadhaatandeeedaatciad baainhbnydauntenemneheniacendudandnersnineasenideacesndniateuiens 5 Waler SUDDIY FR COU IFC RGIS iernare A OEE aman enaen eeia 6 AUTOMATIC Flushing DECES ixrrantosGnewnsitarsatench gaunt cieaeauntiack eundenae ace beg ube tere TATE i 6 VS NING Vet S an neta geenav eames aoe ice deta E E A A AE T A 6 Recommended cleaning Of all stainless Steel cccccccccceccccee cutee nee eee eens eee ee ee eee sees neeeea ee etaeeeeneaeeaeneeggs 6 Enquiries ANG Complaints cccceceececeec et ee eens see ee eee eet EEA EASE EE EEE EASES EEE ES EEE EEA ES EEE ES EE EG REESE SEES EEE EEE EES 7 A aa ava ain quvavusduies ueitetias sinus E aes estee aaa 7 Due to continuous product research and development the information contained herein is subject to change without notification Manufactured by Tom Stoddart Pty Ltd ABN 16 009690251 Distribute
2. is manufactured to the requirements of AS1172 1 and associated reference standards Features e The Slab urinal from Stoddart Manufacturing has full depth sides for superior hygiene e The urinal has a concealed vandal resistant sparge e All internal corners have large radius for cleaning ease and effective drainage e Compressed fibre cement backing provides anti drum noise suppression e Stoddart Slab urinals are manufactured with fall to the waste gt 1 100 typically 1 80 e Top edge can have either a returned edge or a tile edge Due to continuous product research and development the information contained herein is subject to change without notification Manufactured by Tom Stoddart Pty Ltd ABN 16 009690251 Distributed by Revision Date 28 07 2010 149 Jackson Road Sunnybank Hills Qld Printed date 28 07 2010 Tel 61 7 33455011 Fax 61 7 33441000 Web site www stoddart com au Email sales stoddart com au Page 3 of 7 STODDART MANUFACTURING STAINLESS PLUMBING PRODUCTS 9 Referenced Australian Standards Unit Marking to include Maker s Name Model identification Installation amp Maintenance DR Urinal Materials Stainless Steel Copper alloy products are marked Specification Installation and Operation AS 1172 1 1993 Section 1 6 AS1172 1 Clause 2 3 1 Urinal Outlet Dimensions Shall comply with the applicable AS 1172 1 Clause 1 4 4 amp Fig 2 clauses Dezincification resistance ap
3. 33455011 Fax 61 7 33441000 Web site www stoddart com au Email sales stoddart com au Page 6 of 7 STODDART Specification Installation and Operation MANUFACTURING STAINLESS PLUMBING PRODUCTS Remember these does and don ts DO Wash regularly with soapy water or detergent using a clean cloth or a soft bristle brush Remove non washable deposits using an approved cleaner Clean in one direction only along the original polish lines direction of grain Rinse well with clean water and wipe dry DON T e Use steel wool or metallic scrapers to remove non washable deposits e Allow dirt or salt to accumulate or to dry out and harden on the surface e Use cleaners containing harsh abrasives or high bleach contents Stoddart will not accept any responsibility and our warranty will be void if bleach or acidic based cleaning agents are used to clean our stainless steel products If any of the above cleaners must be used It Is imperative that the product is thoroughly washed and rinsed after cleaning with warm soapy water otherwise brown oxidization will appear on the stainless steel surface Important Never use harsh or abrasive cleaners on the product as it is stainless steel Do not use chlorinated or bleached water Warranty Upon receiving a Stoddart product inspect immediately for any visible signs of shipping damage and notify the carrier immediately When removing the product from its packing be careful not to
4. dent or scratch outer surface Any concealed damage should be noted and reported immediately to the freight carrier A claim should be filed with carrier promptly if appropriate Stoddart Manufacturing will not accept responsibility for shipping damage The Standard Terms and Conditions of Sale clearly details Standard Warranty Policy Plumbing Products offer additional conditions as follows e Warranty on materials and labour is limited to 12 months from date of installation e The Warranty does not cover damage caused by abuse misuse or improper application or improper installation e Warranty Claims must be submitted in writing to Stoddart Manufacturing within 14 days of observation of fault e tems may be returned to Stoddart s Factory by the Customer for warranty inspection For valid warranty claims Stoddart will repair or replacement the item and return it to the Customer promptly e For installed products Photos must accompany the Warranty Claim for effective consideration e lf a site visit is required to conduct warranty repairs such work will be carried out during normal business hours 8am to 5pm Mon to Fri Enquiries and Complaints Should you have any queries or complaints please contact the Stoddart Plumbing Division on 07 33455011 Reception or email to plumbing stoddart com au Due to continuous product research and development the information contained herein is subject to change without notification Manufacture
5. I nstallation A qualified plumber must install all Urinals Stoddart can deliver urinals to site and where required can site weld large urinals together inside the room 1 Fit Urinal to waste a Cut Sewer pipe to height to ensure Urinal waste fits inside it b Use the rubber cap supplied to seal the waste to the sewer Plumber may use alternative methods c Make sure there is ample clearance between sewer pipe rubber cap and underside of urinal trough d DO NOT push waste upward 2 Fix Urinal to wall a For Urinals with a Returned Edge fix Z clips to wall horizontally at correct height then hang urinal on Z clips with waste in position Z clips must be fitted to wall before urinal is set in place b For Urinals with Tile Edge position urinal on waste then hold urinal level drill through the tiled edge and then fix to studs in wall c Please be advised that Z clips are not recommended for Urinals over 3 meters long if the wall is not flat 3 Check top edge of urinal is level from left to right and front to back a DO NOT use sparge cover as level reference 4 Concrete Step a Box up front step b Check front edge of urinal is level Recheck that the urinal trough drains to the waste c Pour concrete mix to form front step ensuring that concrete fills in under the front of the urinal to fix it in place 5 Connect flush water Supply to Sparge refer to Plumbing code Due to continuous product researc
6. STODDART Specification Installation and Operation MANUFACTURING STAINLESS PLUMBING PRODUCTS Stainless Steel Slab Urinals Installation and Operation Manual Stainless Steel Slab Urinal This manual is for the following models of Urinals Model Code Stainless Steel Slab Urinal Urinal Slab Top Entry Left Waste Standard Length Urinal Slab Top Entry Right Waste Standard Length Urinal Slab Top Entry Centre Waste Standard Length Urinal Slab Top Entry Two Wastes Standard Length Urinal Slab Rear Entry Left Waste Standard Length SPPL UR S R R Xxxx Urinal Slab Rear Entry Right Waste Standard Length SPPL UR S R C Xxxxx Urinal Slab Rear Entry Centre waste Standard Length SPPL UR S R 2 xxxx Urinal Slab Rear Entry Two Wastes Standard Length Standard Lengths of Slab 0900 1200 1500 1800 2400 2700 3000 3300 3600 3900 Urinal in mm and 4100 Where SPPL Standard Product Plumbing Due to continuous product research and development the information contained herein is subject to change without notification Manufactured by Tom Stoddart Pty Ltd ABN 16 009690251 Distributed by Revision Date 28 07 2010 149 Jackson Road Sunnybank Hills Qld Printed date 28 07 2010 Tel 61 7 33455011 Fax 61 7 33441000 Web site www stoddart com au Email sales stoddart com au Page 1 of 7 STODDART Specification Installation and Operation MANUFACTURING STAINLESS PLUMBING PRODUCTS
7. d by Revision Date 28 07 2010 149 Jackson Road Sunnybank Hills Qld Printed date 28 07 2010 Tel 61 7 33455011 Fax 61 7 33441000 Web site www stoddart com au Email sales stoddart com au Page 2 of 7 STODDART Specification Installation and Operation MANUFACTURING STAINLESS PLUMBING PRODUCTS Recommendations Upon receiving a Stoddart product inspect immediately for any visible signs of shipping damage and notify the carrier immediately When removing the product from its packing be careful not to dent or scratch outer surface Any concealed damage should be noted and reported immediately to the freight carrier A claim should be filed with carrier if appropriate Responsibility Stoddart Manufacturing will not accept responsibility for damage by freight carriers Stoddart thoroughly inspect all products in accordance with QA procedures prior to despatch from our factory The Plumber is responsible to ensure that the urinal is installed in accordance with all specific requirements of local codes and regulations including AS 3500 If questions or complications should arise during the installation of a Stoddart product that cannot be solved using the accompanying instructions please contact our offices or local representatives Note It is the Plumbers responsibility to install this product in accordance with AS3500 Scope This product is design to be used in public places where it is required to be vandal resistant The product
8. d by Tom Stoddart Pty Ltd ABN 16 009690251 Distributed by Revision Date 28 07 2010 149 Jackson Road Sunnybank Hills Qld Printed date 28 07 2010 Tel 61 7 33455011 Fax 61 7 33441000 Web site www stoddart com au Email sales stoddart com au Page 7 of 7
9. h and development the information contained herein is subject to change without notification Manufactured by Tom Stoddart Pty Ltd ABN 16 009690251 Distributed by Revision Date 28 07 2010 149 Jackson Road Sunnybank Hills Qld Printed date 28 07 2010 Tel 61 7 33455011 Fax 61 7 33441000 Web site www stoddart com au Email sales stoddart com au Page 5 of 7 STODDART Specification Installation and Operation MANUFACTURING STAINLESS PLUMBING PRODUCTS Water Supply Requirements All Stoddart Urinals that are coupled with a flush valve require the following e Water supply pipe must be 20mm diameter minimum e Water pressure 250kpa minimum to 500kpa maximum e Flow to the valve face must be 1 0 1 5 litres sec e An inline water filter should be fitted to protect the flushing valve e A Registered Air Gap device must be used All Stoddart Urinals that are coupled with a cistern require the following e Cistern chosen should meet relevant codes amp water efficiency standards e Flush pipe from cistern to urinal should be min 40mm NB e Flush pipe should be as straight as possible Automatic Flushing Devices There are many manufacturers of urinal flushing devices Most are mains powered passive infrared detection systems that automatically flush periodically and after movement is detected They usually come complete with solenoid flush valve with air brake sensor power pack amp control module It is critical that the f
10. lush valve has sufficient capacity to deliver water fast enough to fill the sparge pipe and provide full washing of the back and sides of the urinal It is critical the devices are set to flush sufficient water to flush away all urine The device should have a periodic flush that will maintain the water seal in the S trap Example of ceiling mounted sensor sensor Positionin Install the sensor with the arrow on the sticker pointing towards the urinal CS 1 or CS 2 Sensor Section ani Cleaning Urinals Recommended cleaning of all stainless steel Use a soft cloth that has been dampened with warm soapy water to clean stainless steel Rinse with clean water and dry with a soft cloth Do not use steel wool coarse fabrics or abrasive polishing solutions as they will permanently damage the finish Light stains may be effectively removed by moistening a soft cloth with 10 solution of sodium citrate sprinkling on a light layer of whiting and rubbing in the direction of the grain Thoroughly rinse and dry with a soft cloth If desired the stainless steel may be waxed with a good quality non abrasive liquid or paste automobile wax Due to continuous product research and development the information contained herein is subject to change without notification Manufactured by Tom Stoddart Pty Ltd ABN 16 009690251 Distributed by Revision Date 28 07 2010 149 Jackson Road Sunnybank Hills Qld Printed date 28 07 2010 Tel 61 7
11. plicable to copper alloy Dezincification resistance components in contact with mains water Suitability of Plumbing amp Water Distribution Systems Contamination of water Products for Contact With Potable Water Products For Use In Contact With Drinking Water Dimensional compliance with relevant or corresponding Australian Standard for the pipe or fitting Dimensional compliance with relevant or corresponding Australian Standard for the pipe or fitting Pipe Threads of Whitworth Form Part 2 Fastening Pipe EPEAT EE Flushing Valves Shall comply with MP52 Spec 20 comply with MP52 Spec 20 Installations Warranty amp Installation Pipes and Fittings Joints i e Spigots sockets flanges or other joint components where interfacing other authorized components instructions shall be provided by the manufacture AS 2345 AS 3855 AS4020 AS 3688 AS 3688 MP52 Spec 20 AS3500 Due to continuous product research and development the information contained herein is subject to change without notification Manufactured by Tom Stoddart Pty Ltd ABN 16 009690251 149 Jackson Road Sunnybank Hills Qld Tel 61 7 33455011 Fax 61 7 33441000 Web site www stoddart com au Email sales stoddart com au Distributed by Revision Date 28 07 2010 Printed date 28 07 2010 Page 4 of 7 STODDART Specification Installation and Operation MANUFACTURING STAINLESS PLUMBING PRODUCTS Slab Urinal

Download Pdf Manuals