Home

Mirror Smart Plus Ver11 - ACARD Technology Corp.

image

Contents

1. 4 1 Mirror Smart Cabinet 4 2 SCSI Adapter Option 4 Chapter 2 Hardware Installation 5 2 1 Installing host adapter 5 2 2 ARS 2012PE Mirror Smart compatibility list 6 2 3 What you should know before the installation 6 2 4 ARS 2012PE installation 7 2 4 1 Cable Connection 7 2 4 2 5 2012 Advance Cable Connection 10 2 4 3 Power Connection 11 2 4 4 Other Part of Internal Connection 12 2 4 5 External Power Connection 13 2 4 6 External Cable Connection 13 2 4 7 Configuring your Mirror Smart 15 2 5 ARS 2012PE s control panel instruction 17 Chapter 3 Troubleshooting 19 3 1 Basic troubleshooting 19 3 2 Advanced Troubleshooting 20 For Windows 2000 System 20 Appendix 1 Mirror Smart Plus Compatibility List 24 Appendix 2 SCSI Controller Compatibility List 25 Appendix 3 Mirror Smart Utility 26
2. 5 2012 Mirror Smart Plus SCSI to SCSI RAID 1 Controller for Desktop IDE Hard Drives User s Manual Wy Z Version 1 0 ACARD Copyright 2001 Copyright Trademarks Information The information of product in this manual is subject to change without prior notice and does not represent a commitment on part of the vendor who assume no liability or responsibility for any errors that may appear in this manual ACARD and SCSIDE are the trademarks of ACARD Technology Corp IBM is a trademark of the International Business Machine Corporation Microsoft and the Windows Logo are registered trademarks and Windows is a trademark of Microsoft Corporation All brand names and trademarks are properties of their respective owners This manual contains materials protected under International Copyright Laws All rights reserved No part of this manual may be reproduced transmitted or transcribed without the expressed written permission of the manufacturer and authors of this manual Table Of Contents Chapter 0 What is the SCSIDE Technology 1 Chapter 1 Introduction 3 UR m 3 a 3 13 QUICK 3 4 4 LIS 4 1 4 2 Parts specification
3. firmware version is using inthis Mirror Smart system From the update firmware to select the newest version driver After selecting the firmware file then clike on Open The confirmation of update firmware window will pop up Click on Yes the updating process will go through E B ay es lll ns m CE ee eee ee TE z ee ee For checking Mirror Smart Utility version please click About explanation of the windows please check the following diagram ARS 2012PE Mirror Smart Plus About Utility Version Target ID Number ACARD Mirror Smartis using The Status of device is using Host Bus ID Number amp the Model of SCSI card is using The hard drive on the Eject top of the hard bottom of the system status drive on the system The hard drive on the Eject bottom of the hard top of the system status drive on the system As RAID 1 active The fans on the bottom treat whole system to of the system status be one hard drive only status The fans on the top of the system status To compare and check two hard drive if have same data 30 IDE p For checking Source HD and Target HD if have the same data please click on Compare HDDs button The system will check it During the rebuilding process the diagram same as comparing HD ARS 2012PE Mirror Smart Plus Comparing and checking two hard drives or doing hard drive rebui
4. Setup list f own The rebuilding speed choose For Mac User choose For using read data only choose Setting alarm more than 10 seconds Setting to support ATA66 hard drive Setting to take a turns for reading both hard drives rather than one fF am D iaa P dete Fe debitus F Euren RSS Setting alarm off resetting button if work Setting for fan 3 if detection Setting for fan 2 if detection Setting for fan 1 if detection Setting for fan 0 if detection 27 SCSIDE EEE For changing Mirror Smart size please choose Change Mirror Size under Setup list ARS 2012PE Mirror Smart Plus Setting the Mirror Size Adjusting more bigger than current mirror size only 28 ARS 2012PE Mirror Smart Plus To update firmware please choose Update Firmware under Setup list Then select the firmware file from the updating source For checking currently is using firmware version please see the utility window on Hevison item Modal Ebo topes 110 00 Vemm DELI s Wem mis There rama ATA COELI 42 CED www PLE B Hire EL Suman Payaqa marie ra w lt eo manam 7 i ian n
5. and C will keep lightening And the target of new drive LED will glitter and indicate the hard drive is checking if ready When the new drive is ready LED and C keep lightting the new drive LED amp will keep glittering However LED AC BC2and C will light up and indicate the system is rebuilding data to the new drive During rebuilding or only one drive in the system Mirror Smart Plus will sound a short beep 2 times in every 8 seconds with LED z glittering until replacing a new drive if the source drive have bad sector inside f the fan of the cabinet can not work properly the target of fan fail LED will glitter with alarm one time in every second until the Alarm Off Resetting Button to be pressed for 0 5 second Under this status please contact to the dealer or ACARD distributor 18 E a ARS 2012PE Mirror Smart Plus Chapter 3 Troubleshooting 3 1 Basic troubleshooting If you install your Mirror Smart Plus and it does not function properly follow the basic troubleshooting below 1 Check power supply When starting to check the malfunction devices you should check the power status ON OFF 2 Verify IDE device Always make the IDE device functions is in the Master Standard mode before you install Mirror Smart Plus 3 Check host adapter Verify the adapter card is seated in its slot on the motherboard 4 Check all connectors and cables Check Mirror power c
6. external SCSI devices while you have only one or more than one SCSI devices Step 1 Identify the first 68 pin external SCSI cable Step 2 Plug one end of the 68 pin external SCSI cable into the host adapter external 68 pin connector Step 3 Plug the other end of this SCSI cable into Mirror Smart Plus s external SCSI connector device Step 4 Enable the terminator of Mirror Smart Plus if it is the last device in the SCSI chain Please see the following figure 1 Step 5 Take another external SCSI cable and plug it onto second connector on the same SCSI device if your SCSI Device in daisy chain Step 6 Plug the other end of this SCSI cable onto one of the external connectors on the next SCSI device If you have more SCSI devices please repeat Step 3 to 5 Step 7 Please note that at the last one SCSI device you need to enable its terminator Please see the following figure 2 13 iDE ARS 2012PE Mirror Smart Plus 5 5 DI Connecting device Figure 1 2 mm A Power line 2 Connectto SCSI Adapter Connecting more than one device Figure 2 Other SCSI device e g connect with another Mirror Smart Plus E Power line 2 2 em Enim SCSI Adapter Power line 14 SCSIDE Soy ARS 2012PE Mirror Smart Plus 2 4 7 Configuring your Mirror Smart Plus DIP Switch Setting DIP Switch Setting SCSI I
7. ARS 2012PE Dimentions Length 28cm Wiath 18cm Height 16cm 2 SCSI Adapter Option Please refer to SCSI adapter User s manual ARS 2012PE Mirror Smart Plus Chapter 2 Hardware Installation The hardware installation may include two parts the first part is a simple SCSI host adapter installation Please contact with ACARD for purchas ing SCSI card if you do not have a SCSI card and want to use the AEC 6712UW card option The second part is the Mirror Smart Plus installation which is also straight forward only take about few minutes to complete Please follow the following instructions Before you install an IDE device into the ARS 2012PE you may set the IDE device as Master or Standalone mode by adjusting the jumper setting To connect an IDE hard drive on Mirror Smart Plus please know that if use the old disk which already have the data or a version of OS installed we recommend that you have to backup your data before any installation and re install the OS after the hardware installation It will not work without re install the OS even the old disk have a version of OS from the beginning for DOS and Windows Due to the way SCSI card commands are differ ent from the ON Board IDE controller it will create reading writing error so we strong recommend that after hardware installation just treat the IDE hard disk as the new one 2 1 Installing host adapter For installing the host SCSI adapter please
8. Appendix 4 Technical Support Form 34 ARS 2012PE Mirror Smart Plus Chapter 0 What is the SCSIDE Technology SCSIDE is a revolutionary invention developed by ACARD Technology Ltd It not only offers the unprecedented functionality of converting IDE data flow into SCSI bus but also minimize the converting overhead This technology has opened up a numbers of possibilities of SCSI applica tions to use low cost IDE device The following examples are just a short list of the SCSIDE application 1 Convert IDE hard drive into an external SCSI hard drive for data backup in notebook and desktop PCs 2 Convert IDE 50X CD ROM into a 50X Ultra SCSI CD ROM Which is brand new in the world 3 Convert your favorite IDE DVD ROM into a Ultra SCSI DVD ROM 4 Create DVD ROM Server by daisy chain Multiple SCSIDE DVD ROM 5 Convert 5400rpm or 7200rpm DMA33 66 100 HD into UW SCSI HD for PC Workstation PC Server even for Unix Workstation and Server The basic architecture of SCSIDE is a highly integrated multi CPUs ROC RAID On a Chip design This ROC design utilizes ACARD Technology s many years expertise in IDE SCSI and RISC CPU chip design As illustrated in the following diagram this ROC has multiple CPUS its own ROM and RAM DMA controllers and external ROM interface for flash ROM firmware update ACARD Technology has also polished the firmware design to make the IDE to SCSI conversion a truly PnP
9. which can be easily attached to SCSI bus 1 2 Feature A standalone SCSI to SCSI RAID 1 controller Auto spring out the handle of tray when one of drives is failed Cross platform operation Supports hot drive swap ES Supports Multi tasking performance T T Aluminum amp Steel with Heatsink Frame design Resetting functional alarm off button Lower CPU system loading 24 D Cost effectiveness and high performance Built in RAID on chip ACARD SCSIDE engine rae 1 3 Quick Start Make sure all the cable is connectted to your computer correctly Take the cabinet out of the Mirror system Connect the hard disk with the cabinet s cable Take the cabinet place back to the Mirror Smart s device Make sure the hsndle of tray bar have been closed Turn the system power on Treat the Mirror system as a new hard disk device and start to work 3 z SCSIDE ARS 2012PE Mirror Smart Plus NN 1 4 Specification 1 4 1 Packing List When you open the Mirror Smart Plus cabinet please find out your product model and then check the following packing list ARS 2012PE Drivers CD amp Utilties User Manual AEC 6712UW SCSI card optional 1 4 2 Parts specification 1 Mirror Smart Plus Cabinet Material Aluminum amp Steel Base and Cover ABS shell and front panel Environment Temperature Operating 0 G to 70 C Storage 20 C to 85 C Humidity 15 to 90 Models
10. 2UW For Windows 2000 System 1 Verify the SCSI host adapter Check the device name shown on the list of devices to see if the device name of SCSI adapter is exact the one you have installed with AEC 6712UW The method is shown below Step 1 Double click on My computer Then enter the Control Panel LETT eee oot a dal beet 35h es au rH mer L ma bd i Pat i End m CoCo SRE tp Corrie P Ip Fee misi iar pares asa mE dr duin EE 20 Step 2 Double click System ARS 2012PE Mirror Smart Plus Step 3 In System Properties choose Hardware then click on Device Manager Mar Tre Ces LIBET LIT qua te a kuka 21 5 2012 Mirror Smart Plus Step 4 In SCSI and RAID controllers to double click ACARD AEC6712UW PCI Ultra W SCSI Controller to check if the device you connect to AEC 6712UW is correct ae E a Izd Bim du Hai r M CRE 52 BE roseus AN IDE api consi i iium dre a acd c 2 Verify your IDE device If you can find your IDE device name which you install with AEC 6712UW on D
11. 54 HDDO QUANTUM FIREBALLP LM30 1860 28 0 GB O1 2001 02 01 13 29 54 HDD1 WDC WD30 OBB O04UA1 WD W 28 0 GB OK 1 2001 02 01 13 30 09 HDDO failed 1 2001 02 01 13 30 14 was removed 1 2001 02 01 13 30 44 HDDO QUANTUM FIREBALLP LM30 1860 28 0 GB w 1 2001 02 01 14 03 36 Mirror Smart Utility Version 1 16 started 2001 02 01 14 03 36 Rebuild from HDD1 to HDDO 1 2001 02 01 14 03 36 50 rebuilt 1 2001 02 01 14 03 36 1 adpu160m 1 ACARD Mirrorsmart 196 2 3M Rell 2001 02 01 14 03 36 HDDO0 QUANTUM FIREBALLP LM30 1860 28 0 GB O1 2001 02 01 14 03 36 HDD1 WDC W D30 WD W 28 0 GB OK 1 2001 02 01 14 06 46 60 rebuilt 1 2001 02 01 14 10 37 Smart Utility Version 1 16 closed 2001 02 01 14 10 46 Mirror Smart Utility Version 1 16 started b gt 2001 02 01 14 10 46 Rebuild from HDD1 to HDDO 1 1 01120411 14 160 AG TOS 4 4 33 5 2012 Mirror Smart Plus Appendix 4 Technical Support Form Email support acard com htto www acard com ARS 2012PE F W Version System Configuration Main Board vendor BIOS version SCSI adapter Chipset Memory Dispay card Other card OS version Hard Disk Configuration Hard Disk Model type Capacity Firmware version IDE Device Connect CD ROM model CD R model MO or Removable HDD Others Problem Description M
12. ALARS2012PE10 0 34
13. D number configurations have to be set up on ARS 2012PE The setting of SCSI ID number can be done by using DIP Switch to adjust ON OFF nannannauu 1333333333 LES Eg FESSES Please follow the instruction below and decide the suitable DIP Switch setting E 7 2 SCSIID Number For every unique device SCSI adapter card there is a unique ID number indicating that device Follow the Instruction attached on enclosure to set an ID number until the IDE device get a unique number 1 Terminator Enable Disable Generally when the xe device is at the end of the SCSI bus cable or there is only one device on this cable you should set the termi nator as ON The default value is ON 1 2ON SCSI ID 1 2 2ON SCSI ID 2 S 3 29 ON SCSI ID 4 OFF 4 gt ON SCSI ID 8 5 Reserve RC 6 Reserve 7 gt ON Terminator Enable Default All OFF ID 0 8 Reserve 15 5 2012 Mirror Smart Plus SCSI ID Number Instruction for ARS 2012PE ID 0 ID 1 Default ID 2 ID 3 ID 4 ID 5 ID 6 ID 7 ID 8 ID 9 ID 10 ID 11 ID 12 ID 13 ID 15 16 ARS 2012PE Mirror Smart Plus 2 5 ARS 2012PE s control panel instruction Fan Failure LED If the fan of the cabinet can not work properly the LED will be lit on Hard Drive Error or Malfunction LED This LED will be indicated when the hard drive have error or bad sector inside Hard Drive Access LED
14. This LED means that the Mirror Smart Plus is reading writting data from to the hard disk Hard Drive Power LED The sign will show you if each hard drive has actived with the power Rebuilding LED When you replace one hard drive the original data of the other will be stored and copy completely to new one This time the rebuild ing LED will indicate that data is copying to the new hard drive Alarm Off Restting Button When alarm is actived push the button can be buzz off System Power LED The sign will show you if the Mirror Smart Plus system have been connected with power You must place the handle bar back to Close after finishing all hardware installation Otherwise the Handle Bar Alarm for disk failure will be acting when power on the computer 9 Fan Failure LED 9 Alarm Off Resetting Button Hard Drive Error or Rebuilding LED Malfunction LED System Power LED 9 Hard Drive Access LED 9 Hard Drive Power LED 17 5 2012 Mirror Smart Plus During the normal operation if the Mirror Smart Plus detect one of drives is failed the target of fail drive LED will glitter for 10 seconds with alarm Then the target of fail drive LED will keep lightening with Handle Bar out and indicates the fail drive need to be replaced and installed a new drive After the new drive install into the cabinet and plug into the system the system will check the new drive At this time LED AX B
15. build have been finished Mirror Smart Plus will make long beep sound alarm When the Mirror Smart Plus is doing hot SWAP the system must keep Power order to get a better performance please use Ultra DMA 33 66 or 100 hard disk ARS 2012PE Mirror Smart Plus 2 4 ARS 2012PE installation 2 4 1 Cable Connection Before you connect Mirror Smart Plus system to your device recognize the different interface connectors of SCSI and IDE on the cabinet The longer connector on external rear board which has 68 pins is the SCSI connector Inside the cabinet there is IDE ribbon cable connection Please note this connecior will be connected to IDE hard drive External Board S When the drive is failed you can not remove the hard drive tray until 10 sec later since the alarm is acting E nagaaanaaaa 1333338388 Switch LIL Auto spring out the handle of tray when the drive is failed SCSI connector Hard Disk Cabinet SCSIDE ARS 2012PE Mirror Smart Plus Open cabinet methods Step 1 Make sure the system is power off and using the tool to open the handle bar Step 2 Hold the handle bar and pull the tray out off the cabinet Handle Bar 2 NS Miror Smart Push to open Handle Bar The handle bar is a switch to control hard drive power Do not arbitrarily open the handle bar during system operating unless there is a system ala
16. ctor Step 3 Connect the SCSI cable to internal circuit board aligning with pin 1 to pin 1 oo e 90 9 e e 9 7 24 T e 99699 2 4 3 Power Connection Please find out the power connection from your hardware power supply There is one internal power connectors for device You need to connect the power connectors to Mirror Smart Plus Please see the figures below for the way of connection e Q e 9 9 e e 99 e 9969 E mm W m 11 SCSIDE ARS 2012PE Mirror Smart Plus 2 4 4 Other Part of Internal Connection After you connect the main cable and power connection you will find that there is one small cable connectors need to be connected as well The connector is used to connect External DIP Switch Please find out the right position to connect it Please see the figures below for the way of connection External Jumper Setting Connector 12 ARS 2012PE Mirror Smart Plus 2 4 5 External Power Connection After the above installations are completed your are ready to connect the external power connection please see the graph below Power line 2 4 6 External Cable Connection As this time your IDE harddisk with Mirror Smart Plus is just like an external SCSI device You can follow the direction below to install your
17. evice Manager then you have installed your AEC 6712UW successfully If you can not find your device name but find a named Mirror omart No Device check the internal IDE connector of AEC 6712UW It could be caused by unsuitable connection or malfunction IDE device Follow the instruction below to see how to check your IDE device otep 1 Click on Disk drives to show your hard disk drives E L Fees des Lot eode eae due BIRT pik 3 Faj ere hrs ond VE SR brie 22 SCSIDE Er ARS 2012PE Mirror Smart Plus Step 2 Double click on ACARD MirrorSmart7 9G SCSI Disk Device to choose General to check the Device Status to see if the Mirror Smart Plus device is working properly i p rm ER i po imananmi Parama M git tp ded eel mmm km See Pong E3 Lu qu sir n Fav eaae i 23 E ee H ARS 2012PE Mirror Smart Plus C Appendix 1 Mirror Smart Plus HDD Compatibility List Quantum FireBall AS series FireBall LM series LC series LB series LD series FireBall KX series KA series FireBall CX series CR series EX series FireBall EL series Seagate Barracuda IDE series Barracuda ATA Il 100 series ST320430A ST313620A ST3240AT ST38422A ST36531A IBM DTLA series series series serie
18. lding process When HD have been detected error or malfunction the diagram as following m m a LT U Under this status indicate the HD does not existor HD have been detected error 31 ARS 2012PE Mirror Smart Plus For looking for a history log record just Load Event Log under Event Log list Then select the file for you need and open it to check To open history event log file a History Event Log Window Te ri mim e i Far El 1 d uem pm d pA MIN Oe J nr n 1 AL 1 a l p we WE 3i io i a cg m x1 minn TETE T SE eee ME CR 2 4 ADMD LAON 28 d DOS Ae 12H p J i WH ee SOU VA T APT ee eel SQ 2 ND Ca TOES kupil ID CE lee 3002 L4 E T SIE Gee Eh i aj 32 SCSIDE 1 ARS 2012PE Mirror Smart Plus The Event Log will show the status on every event time This record will help you to identify what is going wrong when problems occur Bt Mirror Smart Utility File Setup EventLog About Status List Mirror Info Event Log 2001 02 01 1 adpu160m 1 ACARD MirrorSmart 196 2 3M 1 2001 02 01 13 29
19. onnector SCSI connector IDE connector device power connector and ribbon cable are connected well Ribbon cables are easily damaged because of un proper fold You can try a new cable known to be good Make sure no connector pins are bent Verify pin 1 on the interface cable is aligned with pin 1 on the drive and host adapter 5 Verify the DIP Switch setting Start over the section configuring your Mirror Smart Plus DIP Switch Setting and power connection to check if the DIP Switch setting is correct 6 SCSI ID conflict If you have multiple SCSI devices please make sure that ID of the SCSI device do not duplicate To reduce the chance the ID switch malfunction it is recommended to test it individually T Poor external cable problems This may happen if the daisy chained with many SCSI device and some of the external cables are not the high density 50 pins or 68pins UW SCSI cables The 25pin to 50 pins SCSI cable has weak grounding so if the daisy chained with more SCSI device to system through the 25 50 pins SCSI cable and having intermittent failure it is recommended that you change this cable with another better quality one 19 5 2012 Mirror Smart Plus 3 2 Advanced Troubleshooting Let s use an example of installing a ARS 2012PE Mirror Smart Plus into ACARD s SCSI Controllers AEC 6712UW to show a proper way of software troubleshooting configuration Assume that we set an SCSI ID number 0 to AEC 671
20. plug and play experience The firmware has been test with almost all brands of IDE DMA33 66 100 HD ATAPI CD ROM DVD ROM No matter what type of IDE device you have ATA hard drive CD ROM CD RW or DVD ROM you can easily plug it on and ready to enjoy your SCSI adventure Because of this intelligent firmware design you do not have to install driver to on you OS to use SCSIDE series of products To the OS it acts like a SCSI device just plug and play ARS 2012PE Mirror Smart Plus The Design Objectives of SCSIDE The primary goals for ACARD s SCSIDE technology has three folds 1 Bring down the cost of using SCSI technology by less expensive device 2 Create some application the people want but currently not available 50 SCSI CD ROM high speed SCSI DVD ROM 3 Transparent plug and play no software driver needed to installed when converting IDE device into SCSI device Welcome our new SCSIDE members and enjoy it ARS 2012PE Mirror Smart Plus Chapter 1 Introduction 1 1 Overview The ARS 2012PE Ultra Wide SCSI RAID 1 Sub System is dedicated as disk mirroring consists of pairs of disk drives that store duplicate data see Figure 1 yet appear to the computer as a single drive which all through SCSI Small Computer System Interface With ACARD micro controller core built in it provides more flexible and stable for high exploring application ARS 2012PE supports IDE devices such as hard disk drive
21. refer to the AEC 6712UW adapter manual comes together with ARS 2012PE kit or your original adapter supplier Then configure your AEC 6712UW software driver using the supplied CD ROM disc E ee H ame LE 5 2012 Mirror Smart Plus 2 2 Mirror Smart Plus compatibility list ARS 2012PE were designed specifically for DMA Hard drive we have fully tested all kind of Hard drive available in our lab the compatibility with different SCSI card and to operate under Mac or Linux system is very stabilization The ARS 2012PE support DMA33 66 100 Hard drive include il IBM HDD MAXTOR HDD QUANTUM HDD SEAGATE HDD Fujitsu HDD WESTERN DIGITAL HDD Please see appendix 1 for the detail of the list or visit www acard com for the newest list 2 3 What you should know before the installation Before you install the Mirror Smart Plus the following things that we strongly recommend two hard drive are in different storage capacity Mirror Smart Plus will treat smallest one as a standard capacity at first time installation When two hard drive have the same storage capacity Mirror Smart Plus will treat top of the hard drive as standard one Normally both hard drives either one could do a hot SWAP During the rebuilding Rebuild light is ON the source drive device should not be removed hot SWAP However the destination device Hard Drive Error Malfunction light is ON is removable ll When the re
22. rm due to the hard drive failure SCSIDE TE ARS 2012PE Mirror Smart Plus The cabinet connection methods Step 1 Find out pin 1 of 40 pin IDE connector on IDE hard drive Step 2 Find out a color line of the internal IDE ribbon cable indicating pin 1 of connector Step Connect the internal IDE cable to IDE hard drive aligning with 1 to pin 1 Step 4 Connect 4 pin power cable to IDE hard drive s power connector Step 5 Revrse the open cabinet methods setps put the cabinet back to the system IDE Hard Disk a EE 5 VA PRIM SCSIDE ARS 2012PE Mirror Smart Plus 2 4 2 ARS 2012PE Advance Cable Connection For the advance cable connection normally the cable inside the box have been installed by producer However before you connect Mirror Smart Plus to your device recognize the inside circuit board and check if all the connector have been connected Also to get familiar with those connec tor will help you to troubleshoot if Mirror Smart Plus would not work properly Below the figure shows the way of opening back case for Mirror Smart Plus Pull to open m SCSI connector 10 ARS 2012PE Mirror Smart Plus The internal rear board connection methods Step 1 Find out pin 1 of 68 pin SCSI connector on internal rear board Step 2 Get a color line of the SCSI ribbon cable indicating pin 1 of conne
23. s 60 GXP 75 GXP Maxtor 54098U8 52049U4 9136604 9409808 9102003 98196 8 5 020 2 Fujitsu MPF 3204AT MPD 3173AT MPD 3084AT Western Digital Expert 13BA Caviar 14300 Caviar 300BB Caviar 600AB Please visit www acard com for the newest list 24 SCSIDE Appendix 2 Mirror Smart Plus SCSI Controller Compatibility List ARS 2012PE Mirror Smart Plus Adaptec ASC 29160 Adaptec ASC 39160 Adaptec 2940U2W Adaptec AHA 2940UW Initio 9100UW Tekram DC 390U2W 53C895 Tekram DC 390U3W ACARD AEC6712UW Tekram 390UF LSI Symbios 53C875 Ultra Wide SCSI controller 25 ARS 2012PE Mirror Smart Plus Appendix 3 Mirror Smart Utility To change some basic setting please choose Preference under Setup list Ez Was may Fa aa iki B re sas Me Deed Tires ouem Fe fes Ge Suami tore Comes i Far Wanu did Ere cuam meire ahan arpa pi rana p Setting for popup up message when errors occur Setting for two hard drives data comparison Setting the time for saving eventlog Setting the time for updating the status of Mirror Smart 26 ARS 2012PE Mirror Smart Plus For setting Mirror Smart functions please choose Mirror Smart Setup under