Home

USER`S MANUAL - Pdfstream.manualsonline.com

image

Contents

1. Model No IMSB73911 IMSG73911 Serial No The serial number is on a sign behind the access panel Write the serial number in the space above Access Panel QUESTIONS If you have questions or if there are missing parts we will guar antee complete satisfaction through direct assistance from our factory TO AVOID DELAYS PLEASE CALL DIRECT TO OUR TOLL FREE CUSTOMER HOT LINE The technicians on our customer hot line will provide immediate assistance free of charge CUSTOMER HOT LINE 1 877 897 7493 Mon Fri 8 a m 5 p m CST CAUTION Read all precautions and instruc tions in this manual before using this equipment Save this manual for future reference USER S MANUAL Visit our website at O www workoutwarehouse com new products prizes fitness tips and much more Table of Contents Postingithe Warning Sigi ermssias rreak iai aR aar a aai a wee ia a ioa E a E a es ea ae ee ee R 2 Important Safety InStrUctionS p siaa yat a a a aa iad atad a eed AD a aia a i aa aad add bria a a Oba yeas 3 Before You BeGIN i060 id icns nee a wie pe hay eee E E EAE E EE wee a E E Ae a ae eda E O een a 6 Choosing a Location for the Hydrotherapy Spa 0 0 e eee eee 7 ASSGMDIV seei ranson o sre tora a an aaa er hee E Sued caus He Re ee ete nse Bee eee 8 Using the Hydrotherapy Spa waa as aari waidai beled a dada
2. Pump Button 2 Turns the spa jets labeled 1 and 2 at the left on and off If the button is pressed once the jets will run providing soothing hydrotherapy If the button is pressed again the jets will shut off The spa also features an automatic mode that heats and filters the water when the spa is left unattended When the power to the spa is first turned on or if the water temperature is below the set temperature the water will be heated as required Note To keep the filter and heat cycles from running the power to the spa must be turned off Light Button Turns the underwater light on and off Temperature Buttons Control the temperature setting of the water The temperature setting can be from 80 F to 104 F The water heats at about 6 F per hour with the cover on Use a medical or other accurate thermometer to check the temperature of the water Note The word COOL will appear in the console display if the temperature of the water is more than 20 F cooler than the set temperature When this hap pens the heater will automatically activate to warm the water The word ICE will appear in the display if the temperature drops below 40 F If this happens the pump will automatically circulate the water and warm the plumbing to keep the water from freezing Neck Jet Valve Controls water flow to the two neck jets see J on page 11 WEU a The hydrotherapy spa is designed to provide years of enjoyment Please
3. pose of the packing materials until assembly is completed and the spa is operating During assembly make sure that all parts are oriented as shown in the drawings Read each assembly step before you begin Tighten all parts as you assemble them unless instructed to do otherwise Before beginning assembly make sure that you have read and understand the information in the box above and on the previous two pages Remove the four 10 x 2 Sheet Metal Screws 46 that secure the indicated Access Panel 25 to the spa Carefully remove the Access Panel and set it aside Be careful not to damage the spa shell 2 Close the valve knob on the drain hose Thread the cap onto the drain hose Locate the four gate valves inside the access open ing there are two gate valves per pump Make sure that the gate valves are open and that the locking clips are snapped onto the stems of the gate valves as shown in the inset drawing Make sure that the six collars are tightened there are two collars per pump and two on the heater Refer to step 1 Re attach the Access Panel 25 to the spa ASSEMBLY REQUIRES THE FOLLOWING TOOLS not included e One phillips screwdriver s A wire connector is provided on the electronics pack of the spa to connect a minimum No 6 AWG 13 3 mm solid copper conductor between the spa and any metal equipment electrical enclosure made of metal metal water pipes or conduit within five
4. caused by improper pH levels is not covered under the warranty To maintain the proper pH level test the pH of the water regularly To test the water purchase a pH test kit at a pool and spa supply store The pH reading should be between 7 2 and 7 8 If the level is too low add a pH increaser usually soda ash If the level is too high add a pH reducer usually sodium bisulfate Test the water again after five minutes See the instructions with your pH test kit for additional infor mation about testing and adjusting the pH SANITIZING THE HYDROTHERAPY SPA The most common sanitizing agent is a solid bromine concentrate The amount required varies according to several factors such as user load temperature and water conditions Proper water maintenance is a com plex process Contact your local pool and spa supplier for information concerning which chemicals you should use in your area to sanitize the spa CHANGING THE FILTER CYCLE The spa will filter the water every 12 hours The dura tion of the cycle can be adjusted to last 2 to 5 hours Press the temperature up or temperature down button on the console When the display begins to flash press the pump button The display will read F2 To change the time press the temp up button until the desired time is reached Press the pump button to confirm the selection As spa usage increases the duration of the filter cycle may need to be increased 14 ATTACHING AND REMOVING TH
5. dag eau gee Rea ou Pees a aAa a be mal 10 Spa Shell Diagram 2cncacwadediek duane aura bee eee vend whe AEE O Ee hae oases a N ii aa 11 Using the Controls sera saida Gis e 2 Oheeeee se be bese Ree tee Pes eel ee Dia maa N 2408 s 12 IVIL MANIC Se bona ceca ce arse cairns RARA PRR na oe ceca ata ge ee fe eae arch EE DAER Ear IS ae ees PREE RERE EEEN 13 TrOuBIGSHOOUNG 24 2dcnaee8 eepe a todd boda OOO Fete ae bende etd a ade tegen 16 Part Eisi siege a aac ae eR aR are ee Ran at Maa ee nae an eee as Rates 18 Exploded Drawing es irre deen e phe eee eee oe eee ey pee edad ears oul et swe eae ha 19 Ordering Replacement Parts saira sardaa 0 0 cee eet eee Back Cover Limited Wattanty sate Wea oe get eee de ould ae RG Sider di eee ee Bee oUt we eee ERS Back Cover Posting the Warning Sign The warning sign shown below must be posted on a wall or fence where it will be visible to all users of the hydrotherapy spa Whenever the spa is moved the sign must also be moved and reposted near the spa If the sign becomes lost or illegible call our toll free Customer Hot Line at 1 877 897 7493 to obtain a replacement sign Post the sign as described above DURING PREGNANCY SOAKING IN HOT WATER MAY CAUSE DAMAGE TO THE FETUS LIMIT USE TO 10 MINUTES AT A TIME PREVENT DROWNING PREVENT CHILD DROWNING Spa heat speeds up the effect of alcohol drugs e Water attracts children or medicine and can cause unconsciousness Always attach spa cover after each u
6. feet of the spa Spa Shell A ey ia o e Gate Valve Locking Clip 3 Insert the pillow 47 into the lounge seat receptacle The pillow can be rotated 180 to change between the high and low positions 4 The hydrotherapy spa operates on a 240 volt power source and must be wired directly to a 40 amp Ground Fault Circuit Interrupter GFCl protected circuit breaker installed in your home This must be performed by a qualified licensed electrician A wiring diagram is found on the inside of the electronics package for reference Under no circumstance should the spa be wired by someone other than a qualified electri cian Before you have the spa wired make sure it is in the desired position and that it can be easily serviced 5 Make sure that a qualified electrician has wired the spa to a 240 volt power source Remove the two warning decals see page 5 from the spa shell Using a damp cloth wipe the spa shell clean Before filling the spa make sure that it is in the desired position and that there is room to easily service it Once the spa is filled it will have to be drained before it can be moved Insert a garden hose into a filter housing and fill the spa to the level shown at the right Do not use soft water The spa may be filled with cold water howev er if warm or hot water is used the spa will be ready for use sooner Do
7. follow the guidelines below to properly maintain your spa MAINTENANCE SCHEDULE Daily e Check the water level and refill the spa to the level shown in step 5 on page 9 e Check the pH balance and sanitizer level Adjust if necessary see WATER CHEMISTRY on this page Weekly e Clean the spa shell at the waterline Check and thoroughly clean the filters see CHECKING AND CLEANING THE FILTERS on this page e Replace the filters if needed see ORDERING REPLACEMENT PARTS on the back cover of this manual Monthly e Clean the spa cover see MAINTAINING THE SPA COVER on this page e Soak the filters for two hours in a trisodium phos phate TSP solution Rinse the filters in clean water e Replace the filters if needed see ORDERING REPLACEMENT PARTS on the back cover of this manual Every Three Months e Drain the spa and refill it with clean water Sanitize and test the pH of the water e Check for any leaks around the pump or joints in the pipes The seals will wear out over time detect ing leaks early can reduce repair costs e Clean the interior of the spa Do not use solvents or waxes MAINTAINING THE SPA EXTERIOR The premium cedar surround has been treated at the factory For information and supplies to maintain the beauty and color of your premium cedar surround contact your local pool and spa supply store CLEANING THE SPA SHELL The spa shell should be cleaned with a mild soap solution do not
8. long hair to float freely in the water long hair should be restrained with a bathing cap 8 IMPORTANT Do not allow the hydrotherapy spa to be exposed to direct sunlight when it is empty The surface of the spa shell can reach temperatures as high as 150 F in a mat ter of minutes if exposed to the sun while it is empty These high temperatures can cause significant damage such as blistering of the shell surface and warping of the spa shell Any damage caused by sun exposure is not covered under the warranty 9 Do not bring any object into the hydrotherapy spa that could damage the spa shell 10 Never insert any object into any opening 11 Do not use breakable containers in or near the hydrotherapy spa 12 Do not sit on the spa cover or place objects on it it is not designed to support weight 13 Remove any water or debris that may collect on the spa cover 14 Keep children under the age of 12 and pets away from the hydrotherapy spa when it is not in use 15 Keep all chemicals away from children and pets 16 The pH and chemical balance of the water must be maintained as explained in this man ual see pages 10 and 13 Failure to do so may cause injury to users or damage to the hydrotherapy spa and will void the warranty 17 Individuals with infections and open sores or wounds should not use the hydrotherapy spa Bacteria thrive in warm and hot water Always keep your spa disinfected and main tain the pro
9. night opera tion see USING THE CONTROLS on page 12 The spa includes both red and blue covers for the light The temperature probe monitors water temperature The volcano jet provides a soothing foot massage The whirlpool jet diverts the water flow three differ ent ways By turning the outer ring you can divert the water flow between the volcano jet D the other jets on the spa and the whirlpool jet E which cre ates a whirlpool action Note The outer ring may be hard to turn while the pump is turned on high The four suction fittings provide water to the pumps The suction covers should always be in place over the fittings Never operate the spa with out the suction covers in place An optional ozone generator can be purchased and installed to utilize the ozone jet Ozone helps sani tize the spa with minimal chemical treatment The console controls the spa jets turns the under water light on and off and adjusts the water tem 11 perature setting see USING THE CONTROLS on page 12 The four air controls regulate the air flow to the whirlpool hydrotherapy and volcano jets The two neck jets can be adjusted to spray sooth ing water on your neck To activate the neck jets turn the on off valve P counterclockwise To turn the neck jets off turn the on off valve clockwise The twenty rotary jets provide a spinning massage The dual rotary jets provide a pulsating massage ac
10. not overfill the spa Refer to the inset drawing Set the Filters 5 into the filter housings Next screw the Filter Covers 3 into Garden Hose the filter housings until they are fully seated l 6 Pull down one of the straps on the Spa Cover 11 and hold the Buckle 26 against one of the premium cedar panels on the spa Note To position the Buckle correctly have a second person hold the strap on the opposite side of the Spa Cover snug The Spa Cover must be snug Do not place the Buckle over the grooves between the premium cedar panels Refer to the inset drawing Remove the latch from the Buckle 26 Attach the Buckle to the premium cedar panel with two 4 x 3 4 Screws 27 Attach the other three Buckles 26 to the premium cedar panels in the same way Remove the Spa Cover 11 from the spa Using the Hydrotherapy Spa The hydrotherapy spa is designed to seat seven per sons The spa holds approximately 375 gallons of water and offers a heating system 80 F to 104 F a filtration system and adjustable hydrotherapy jets Follow the guidelines below to use and maintain the spa for your long term enjoyment WIRING THE HYDROTHERAPY SPA The hydrotherapy spa is designed to operate with a 240 volt AC power source It must be wired directly into a 40 amp Ground Fault Circuit Interrupter GFCl protected circuit breaker No other appliance should be on the same circuit
11. qualified electrician 10 Once you have tested the GFCI you should verify the water flow from the pumping unit Set the air control on the console to the lowest setting see USING THE CONTROLS on page 12 The pumping unit will heat the water as it pumps Cover the hydrotherapy spa with the spa cover The spa cover must be tight see SECURING THE SPA COVER ON THE SPA on this page The water will heat at about 6 F per hour with the cover on If you are using the spa indoors and the room temperature is maintained at 70 F it will take approximately 6 to 8 hours for the water to reach the set temperature The temperature and the water flow can be set or changed with the controls on the console see USING THE CONTROLS on page 12 SECURING THE SPA COVER ON THE SPA To secure the spa cover snap the latches on the spa cover into the buckles on the premium cedar panels To lock the buckles insert the key and turn it clockwise 1 4 turn To unlock the buck les insert the key and turn it counterclockwise 1 4 turn Always keep the buckles locked when the spa is not in use Keep the keys in a safe place out of the reach of children Buckle Spa Shell Diagram The filters can be removed for cleaning or replace ment see CHECKING AND CLEANING THE FIL TERS on page 13 The underwater light can be used for
12. use solvents or waxes The spa should always be clean and dry before being moved or stored 13 MAINTAINING THE SPA COVER The spa cover should be cleaned monthly To clean the spa cover use water and a non abrasive cleaner on the entire cover Rinse the cover with a garden hose to remove any cleaner residue Dry the cover entirely Use a non silicone based vinyl conditioner on the cover after you clean it This will help protect the cover from sun damage CHECKING AND CLEANING THE FILTERS The filters should be checked periodically for build up of dirt and oil If the filters need to be cleaned follow the steps below 1 Turn off the power 2 Unscrew the filter gt Filter covers 4 Lift the the filters out Cover Ey of the filter housings 4 5 Check the filters for Filter dirt and debris If the filters need to be cleaned rinse the fil ters with a hose If the filters are still dirty soak them in cleaning solution from a pool and spa supply store Inspect the filters for damage Replace the filters if the are damaged Insert the cleaned or new filters into the filter hous ings 8 Re attach the filter covers Filter 6 he WATER CHEMISTRY Maintaining the pH level of the water is very important to the operation of the spa To maintain the proper pH level and to sanitize the spa you can purchase a chemical starter kit from your local pool an
13. ATER LEVEL DROPS a Aclamp or seal inside the pump compartment may be loose Check inside the pump compart ment for excess water and watch the pump unit while it is operating to see if water drips from any of the plumbing If you can identify the location of the leak inside the spa jet unit tight en the clamp or replace the damaged seal Some water loss due to evaporation is normal If rapid water loss occurs or if you notice wet ness on the floor around the hydrotherapy spa the spa shell may have a leak Contact your local pool and spa service provider for repairs 17 10 SYMPTOM THE SPA JET UNIT CONTINUES TO RUN AFTER IT HAS BEEN SHUT OFF a To turn the main jets off press pump button 1 once or twice Note If the actual spa water temperature is below the set temperature or if the spa is running a filter cycle the heater pump motor will not shut off Part List model No 1msB73911 IMSG73911 R0302A Key No Qty OONOOARWND ORR OAANMAR A ROA ROAAH AANA A k h i ek OD ek Description Thermometer Fitting 3 wire Power Cord Filter Cover with O Ring Filter O Ring Filter Rubber Isolator Blue Light Cover Red Light Cover 10 x 1 Sheet Metal Screw 2 speed Pump Spa Cover Dual Rotary Jet Face Jet Pump Motor O ring Heater Electronics Package Medium Jet Housing 10 x 1 1 4 Screw Suction Cover Air Control Knob 1 speed Pump 4 wire Power Cord Diverter Basket 1 4 Lock W
14. Connection of the spa to the 240 volt power source must be per formed by a qualified licensed electrician and must comply with all local state and federal elec trical codes Please have the electrician refer to the instructions on the inside of the electronics package for information about converting the spa to 240 volt operation Once the spa is filled with water the power can be turned on Note The first time the power is turned on the spa will start automatically TESTING AND TREATING THE WATER The first time you use the spa you should test and treat the water You must also treat the water each time you refill the spa A test strip and a chemical pack are available at your local pool and spa store Follow the directions carefully on the chemical pack to test and treat the water Always keep the chemicals away from children and pets See WATER CHEMISTRY on page 13 for information concerning proper water maintenance STARTING THE HYDROTHERAPY SPA You should always test the GFCI before using the hydrotherapy spa First turn on the spa by pressing the pump button 1 on the console see USING THE CONTROLS on page 12 Once the spa is running press the GFCI test button The spa should shut off Press the reset button The spa should resume nor mal operation If the spa continues to run after the test button is pressed the GFCI is damaged Do not use the spa until the GFCI has been repaired or replaced by a
15. E ACCESS PANEL Turn off the spa power To remove the indicated Access Panel 25 Remove the four 1 4 x 20 x 1 1 2 Machine Screws 46 that secure the Access Panel to the spa Carefully remove the Access Panel and set it aside SS To replace the Access Panel hold the Access Panel in place and secure it with the 4 1 4 x 20 x 1 1 2 Machine Screws 46 Be careful not to overtighten the Screws DRAINING THE HYDROTHERAPY SPA The hydrotherapy spa should be drained at least four times per year and refilled with clean water You may need to drain the spa more often depending on the user load This must be done because after repeated chemical treatment the water becomes chemically saturated Once this happens additional chemical treatment of the water is no longer effective The spa should also be drained if you will not be using it for long periods of time The spa must always be drained before major repairs are made The hydrotherapy spa should always be covered when it is empty Direct sunlight can cause exten sive damage The surface of the spa shell can reach temperatures as high as 150 F in a matter of minutes if exposed to the sun while it is empty These high temperatures can cause significant damage such as blistering of the shell surface and warping of the spa shell Any damage caused by sun exposure is not covered under warranty To dr
16. NAME of the product IMAGE RENEW 739 hydrotherapy spa oa The SERIAL NUMBER of the product see the front cover of this manual A The KEY NUMBER and DESCRIPTION of the desired part s see the PART LIST and the EXPLODED DRAWING on pages 18 and 19 Limited Warranty ICON Health amp Fitness Inc ICON warrants this product to be free from defects in workmanship and mate rial under normal use and service conditions for a period of ninety 90 days from the date of purchase ICON extends a limited five 5 year warranty on the spa shell structure ICON extends a limited two 2 year war ranty on the pump motor and electronics package This warranty extends only to the original purchaser ICON s obligation under this warranty is limited to replacing or repairing at ICON s option the product through one of its authorized service centers All repairs for which warranty claims are made must be pre authorized by ICON This warranty does not extend to any product or damage to a product caused by or attributable to freight damage abuse misuse improper or abnormal usage or repairs not provided by ICON authorized ser vice personnel to products used for commercial or rental purposes or to products used as store display mod els Specifically excluded are damages caused by or attributable to the following incidents any damage to the premium cedar surround or frame attributable to improper handling or freight damage damage resulting fr
17. ain the hydrotherapy spa follow the steps below 1 Using the console adjust the temperature to the lowest setting 2 Shut off the power to the spa at the circuit breaker or GFCI 3 Remove the access panel from the spa see ATTACHING AND REMOVING THE ACCESS PANEL on page 14 4 Pull the hose out and hold it above the waterline Remove the cap open the valve knob and attach a garden hose to the drain hose Lower the hose and drain the spa 5 When the spa is empty remove the garden hose close the valve knob and re attach the cap and return the drain hose inside the spa 6 Re attach the access panel 7 Refill the spa and treat the water with chemicals see pages 10 and 14 DRAINING THE PUMPS After the hydrotherapy spa is drained the jet pumps should also be drained if the spa will be stored for more than thirty days or if it may be exposed to freez ing temperatures Turn off the power to the spa To drain the jet pumps remove the access panel from the spa unit see ATTACH ING AND REMOVING THE ACCESS PANEL on page 14 Locate the jet pumps inside the spa Loosen the indicated collar on each of the pumps WINTER USE AND CARE The hydrotherapy spa is designed for year round use If you decide to store the spa for the winter store it in a warm dry location Follow the steps below to winter ize the spa 1 Make sure the power to the
18. asher Filter Door Access Panel Buckle 4 x 3 4 Screw 8 1 1 2 Screw Console with Overlay Hose Washer 1 4 Washer Diverter Valve Trim Plate Foam Weir Key No Qty Nw NaN _ Bosse aNwynyH nNo an GSnw technicians Indicates a non illustrated part Description Volcano Jet Nozzle Housing Small Rotator Large Rotary Jet Face Ring Small Nozzle Jet Ring Nozzle Bushing Pivot Ring Medium Nozzle Drain Plugs 10 x 2 Sheet Metal Screw Pillow Drain Plug O ring Corner Panel Hose Cap Skimmer Housing Dual Rotary Jet Neck Jet Whirlpool Jet Overlay Ground Wire Key User s Manual Large Warning Sign Warning Sign Light Bulb Corner Panel Indicates a part that is serviceable only by service Specifications are subject to change without notice Exploded Drawing modei no msB73911 1MSG73911 R0302A 49 52 167 16 O17 QV 16 17 16 17 19 Ordering Replacement Parts To order replacement parts simply call our Customer Service Department toll free at 1 877 897 7493 Monday through Friday 8 a m until 5 p m Central Time excluding holidays To help us assist you please be prepared to give the following information when calling 1 The MODEL NUMBER of the product IMSB73911 or IMSG73911 2 The
19. close to a source of water We recommend that you place the spa on a water and stain resistant non slip surface Do not use the spa on rough or sharp surfaces such as gravel or wood chips Be sure that the location you choose is stable It must be able to support the weight of the spa when it is filled with water plus the weight of the occupants The spa weighs approximately 3 300 pounds when it is filled with water Consider environmental factors such as rain wind shade and sunlight You should be able to monitor the use of the spa from your home to prevent unauthorized use by children You may want to enclose the spa with a fence and self latching gate to prevent unautho rized use Be sure that there is room around the spa to per mit servicing of the unit The dimensions of the spa are 84 W x 84 L x 39 H You should allow for this size when choosing the location The spa is not designed to be installed below ground level However it is compatible with a deck system that is built flush with the top of the spa provided you leave access to the motor for ser vice 10 Be sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the spa Assembly _ Before beginning assembly carefully read the following information and instructions e Place all parts in a cleared area and remove the packing materials from the spa shell Do not dis
20. d spa sup ply store CAUTION The chemicals used to maintain the pH balance of the water and to sanitize the water can be dangerous Always follow these basic guide lines when handling the chemicals 1 Always read and follow the directions on the label unless directed otherwise 2 Never mix different chemicals 3 Do not exceed the recommended amounts of chemicals follow the directions on the label Keep all chemicals out of the reach of children and pets Keep all containers closed tightly when not in use Never add water to the chemicals always add the chemicals to the water as directed Always store chemicals in a cool dry place 6 7 MAINTAINING THE PROPER PH BALANCE The pH factor is a measure of the relative acidity or alkalinity in the water and is measured on a scale of 1 to 14 Pure water has a value of 7 which is neutral Any value above 7 is alkaline and any value below 7 is acidic You should maintain a slightly alkaline pH level between 7 2 and 7 8 in the hydrotherapy spa Severe problems can occur when the pH balance is not maintained within this range If the pH level exceeds 7 8 dissolved minerals can build up and clog the plumbing in the spa jet unit If the pH level falls below 7 2 the acid level in the water will begin to cor rode the metal parts in the spa jet unit Also the sani tation agents in the water will not be effective if the pH level is not properly maintained Damage
21. elec tronics pack of the spa by a minimum No 6 AWG 13 3 mm solid copper conductor see instruction 21 23 Do not operate the pump motor when the hydrotherapy spa is empty The pump motor may be seriously damaged if it is operated without water circulating 24 DANGER Risk of drowning Exercise extreme caution to prevent unauthorized and unsupervised use of the hydrotherapy spa by children Children must always be supervised 25 DANGER To reduce the risk of drowning e Never use the hydrotherapy spa alone e Children should not use the spa unless they are supervised by an adult Keep pets away from the spa ai all times e Always replace and lock the spa cover when the spa is not in use 26 WARNING To reduce the risk of injury The water temperature should never exceed 104 F Temperatures between 100 F and 104 F are considered to be safe for healthy adults However if you plan to remain in the hydro therapy spa for more than 10 to 15 minutes a lower temperature is recommended Lower temperatures are also recommended for chil dren Children should not be allowed to swim under the surface of the water in the spa 27 WARNING To reduce the risk of injury Before entering the hydrotherapy spa always use an accurate thermometer to determine the water temperature 28 WARNING To reduce the risk of injury Pregnant women should consult with their 29 30 31 32 33 34 physician before us
22. es do not allow limitations on how long an implied warranty lasts Accordingly the above limitation may not apply to you This warranty gives you specific legal rights You may also have other rights which vary from state to state ICON HEALTH amp FITNESS INC 1500 S 1000 W LOGAN UT 84321 9813 Part No 184343 R0302A Printed in USA 2002 ICON Health amp Fitness Inc
23. gh Friday 8 a m until 5 p m Central Time excluding holidays To help us assist you please mention the product model number and serial number when calling The model number is IMSB73911 or IMSG73911 The serial number can be found on a decal on the access panel inside the spa see the front cover of this manual Before reading further please familiarize yourself with the parts that are labeled in the drawing below Spa Shell Access Panel Locking Buckle Choosing a Location for the Hydrotherapy Spa There are many factors to consider when choosing a location to set up the hydrotherapy spa These factors vary depending on whether you plan to use the spa inside or outside We have listed several factors you may wish to consider as you decide where to set up the spa If you set up the hydrotherapy spa inside 1 The spa will increase the level of humidity in your home The location you choose should be well ventilated You may need to install a ventilation fan or use a dehumidifier The spa should be located near a power source capable of supplying 240 volts AC power It must be wired directly into a 40 amp Ground Fault Circuit Interrupter GFCl protected circuit breaker No other appliance should be on the same circuit The spa should be close to a source of water Do not use the spa
24. ing the hydrotherapy spa Pregnant women should not use the spa if the water temperature is above 100 F the unborn child could be seriously harmed This is especially important during the first 90 days of the pregnancy DANGER To reduce the risk of drowning Prolonged immersion in the hydrotherapy spa may cause hyperthermia The causes symp toms and effects of hyperthermia may be described as follows Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98 6 F The symp toms of hyperthermia include an increase in the internal temperature of the body dizzi ness lethargy drowsiness and fainting The effects of hyperthermia include failure to per ceive heat failure to recognize the need to exit the spa or hot tub unawareness of impending hazard fetal damage in pregnant women physical inability to exit the spa or hot tub and unconsciousness resulting in danger of drowning WARNING The use of alcohol drugs or medication can greatly increase the risk of fatal hyperthermia WARNING To reduce the risk of drowning Do not use the hydrotherapy spa if you are under the influence of alcohol or drugs Heat from the water in conjunction with alcohol or drugs can cause loss of consciousness WARNING To reduce the risk of injury or drowning Consult your physician about pos sible side effects of any medications you may be taking before using the hyd
25. l times Never place any electrical appliance Attach spa cover after each use within 5 feet of spa Spa heat can cause hyperthermia Read and follow owner s manual and unconsciousness and instructions Spa heat in conjunction with alcohol drugs or medication can cause unconsciousness Note This marking is to be removed only by the owner _ T il i A WARNING Read all instructions before using the hydrotherapy spa ICON assumes no responsibility for personal injury or property damage sustained by or through the use of this product SAVE THESE INSTRUCTIONS Before You Begin Congratulations for selecting the new IMAGE RENEW 739 hydrotherapy spa The innovative RENEW 739 allows you to enjoy all the benefits of hydrotherapy in the comfort and privacy of your home Hydrotherapy is a proven method for soothing tired muscles after exercise or for relieving the stress of a busy life The warm environment stimulates blood flow which is essential in the healing process and the powerful massage action further eases tension and stress throughout the body The IMAGE RENEW 739 gives you the specialized treatment you need to feel your best Air Controls Air Console Gontrol For your benefit read this manual carefully before using the IMAGE RENEW 7339 If you have ques tions after reading the manual please call our Customer Service Department toll free at 1 877 897 7493 Monday throu
26. ntact our customer service department b The pump may have a bad bearing Contact our customer service department 16 a Make sure that the hydrotherapy spa is fully covered with the spa cover The spa cover must be tight for the water to heat Set the air control to low The water will heat at a rate of 6 F per hour If you are using the spa indoors and the room temperature is main tained at 70 F it will take approximately 6 to 8 hours for the water to reach the set temperature b If you are using the hydrotherapy spa outdoors it may take longer for the water to heat See the chart below for the approximate heating time Air Temperature Heating Time 70 F 6 to 8 hours 50 F to 70 F 30 F to 50 F 9 to 11 hours 12 to 14 hours If the water still has not heated after four days contact our customer service department SYMPTOM THE WATER IS NOT BEING CLEANED BY THE FILTER a Check to see if the filters are in place Clean the filters if they are dirty b Check the chemical balance of the water If the pH is incorrect the sanitizing agents will not function properly See the section on maintain ing the proper pH balance on page 14 SYMPTOM THE WATER PULSATES OR THERE IS MINIMUM WATER FLOW a This usually occurs only when the water level is low Add water until it is 2 to 4 above the skim mer basket b The Filter Covers may not be tight Make sure the Filter Covers are tight 9 SYMPTOM THE W
27. om improper winterization damage to the spa shell resulting from improper chemical treatment damage to the spa shell resulting from exposure to extreme temperatures or damage to the spa shell resulting from expo sure to direct sunlight and ultraviolet rays while the spa is empty damage to the pump motor plumbing and components due to improper maintenance chemical treatment or exposure or damage resulting from failure to properly follow user s manual installation operating or maintenance instructions Also excluded are con sumable components including but not restricted to filter cartridges No other warranty beyond that specifi cally set forth above is authorized by ICON ICON is not responsible or liable for indirect special or consequential damages arising out of or in connection with the use or performance of the product or damages with respect to any economic loss loss of or damage to property including water damage loss of revenues or profits loss of enjoyment or use costs of removal installation or other consequential damages of whatsoever nature Some states do not allow the exclusion or limitation of incidental or consequential damages Accordingly the above limitation may not apply to you The warranty extended hereunder is in lieu of any and all other warranties and any implied warranties of mer chantability or fitness for a particular purpose is limited in its scope and duration to the terms set forth herein Some stat
28. on carpet or other material that may be damaged by moisture We recommend that you place the spa on a water and stain resis tant non slip surface with a floor drain for any water that may splash from the spa Be sure that the location you choose is stable It must be able to support the weight of the spa when it is filled with water plus the weight of the occupants The spa weighs approximately 3 300 pounds when it is filled with water Do not use the spa above a finished living area due to the risk of water damage Be sure that there is room around the spa to per mit servicing of the unit The dimensions of the spa are 84 W x 84 L x 39 H You should allow for this size when choosing the location The spa is not designed for in floor installation However it is compatible with a deck system that is built flush with the top of the spa provided you leave access to the motor for service Be sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the spa If you set up the hydrotherapy spa outside 1 Check local building codes concerning the use of outdoor spas The spa should be located near a power source capable of supplying 240 volts AC power It must be wired directly into a 40 amp Ground Fault Circuit Interrupter GFCI protected circuit breaker No other appliance should be on the same circuit The spa should be
29. out of the housing and insert a new light bulb Re attach the light housing to the spa shell Re attach the access panel to the spa 15 Troubleshooting Most problems can be solved by following the simple steps below Find the symptom that applies and follow the steps listed If further assistance is needed call our Customer Service Department toll free at 1 877 897 7493 Monday through Friday 8 a m until 5 p m Central Time 1 SYMPTOM THE SPA WILL NOT OPERATE 6 SYMPTOM THE WATER DOES NOT HEAT a Check to see if the GFCI breaker is tripped or was not turned on Reset the GFCI breaker SYMPTOM THE CIRCUIT BREAKER OR THE GFCI TRIPS WHILE THE SPA IS OPERATING a Reset the circuit breaker or the GFCI If the cir cuit breaker or the GFCI trips again contact a qualified electrician for service SYMPTOM THE PUMP HUMS a The filters may be dirty or damaged Remove the filters from the filter housing and clean or replace the filters see page 13 b The pump may have a foreign object stuck in the impeller Contact our customer service department c The pump may have a loose wire connection Contact our customer service department SYMPTOM THE PUMP HUMS BUT DOES NOT ROTATE a The pump may be jammed Contact our cus tomer service department If your spa is no longer under warranty contact a local spa and pool service provider SYMPTOM THE PUMP IS NOISY WHILE OPERATING a There may be debris in the pump Co
30. per chemical balance 18 Shower before and after using the hydrother apy spa This will remove any deodorant per Spiration or body oils that could contaminate the water Showering after will remove any residual chemicals and any bacteria that may have been in the spa 19 WARNING The Ground Fault Circuit Interrupter GFCI must be tested before each use To test the GFCI press the test button while the hydrotherapy spa is running The spa should shut off Press the reset button The spa should resume normal opera tion If the spa continues to run after the test button is pressed then the GFCI is damaged Do not use the spa until the GFCI has been repaired or replaced by a qualified electrician 20 DANGER Risk of electric shock Keep all electrical appliances such as radios tele phones televisions and lights at least five feet away from the waier 2 ok A wire connector is provided on the electron ics pack of the hydrotherapy spa to connect a minimum No 6 AWG 13 3 mm solid copper conductor between the spa and any metal equipment electrical enclosure made of metal metal water pipes or conduit within five feet of the spa 22 DANGER Risk of electric shock Do not set the hydrotherapy spa within five feet of any metal objects or surfaces As an alternative you may use the spa within five feet of metal objects if each metal object is permanently connected to the wire connector on the
31. rotherapy spa Heat from the water in conjunction with some medications may cause drowsiness and increase the risk of drowning Other medica tions can effect blood pressure heart rate and circulation Do not use the hydrotherapy spa immediately after strenuous exercise If you feel pain or dizziness at any time while using the hydrotherapy spa discontinue use and contact a physician WARNING To reduce the risk of injury It is especially important for persons over the age of 35 or persons with pre existing health problems such as obesity heart disease high or low blood pressure circulatory prob lems or diabetes to consult their physician before using the hydrotherapy spa 35 WARNING The spa jets produce a stream of water with relatively high pressure Prolonged exposure of a localized area of the body may cause bruises to the skin 36 The included warning sign must be posted where all users of the hydrotherapy spa can see and read it See POSTING THE WARNING SIGN on page 2 37 WARNING DECAL PLACEMENT Locate the decals shown below and familiarize yourself with the information on the decals Continuous exposure of the spa surface to direct sunlight may cause damage to the spa s surface and will void the surface warranty to this spa To avoid sun damage the cover should be in place when the spa is not in use PREVENT DROWNING PREVENT ELECTROCUTION Supervise your children at al
32. se Immediately leave spa if uncomfortable or _ Sleepy IMAGE is a registered trademark of ICON Health amp Fitness Inc 2 Important Safety Instructions AWARNING To reduce the risk of drowning electric shock or serious injury read the fol lowing important precautions before using the hydrotherapy spa READ AND FOLLOW ALL INSTRUCTIONS 1 It is the responsibility of the owner to ensure that all users of the hydrotherapy spa are adequately informed of all precautions 2 Use the hydrotherapy spa only as described in this manual 3 The hydrotherapy spa is intended for home use only Do not use the spa in a commercial rental or institutional setting 4 Use the hydrotherapy spa only on a level sur face Do not use the spa on carpet or other materials that could be damaged by moisture 5 The hydrotherapy spa will weigh approxi mately 3 300 pounds when it is filled with water Make sure that the location you select for the spa will support this weight plus the weight of the occupants 6 Inspect and tighten all parts regularly Replace any worn parts immediately 7 DANGER Risk of injury Do not remove or alter the covers on the suction fittings Never operate the hydrotherapy spa if the suction guard is missing or broken If you need to replace a suction fitting or pump make sure you use only manufacturer recommended replacement parts Keep hair and body parts away from the suction guard Do not allow
33. spa is turned off 2 Drain the spa see DRAINING THE HYDROTHER APY SPA on the previous page and this page 3 Remove all remaining water from the spa shell Dry the spa shell with towels 4 Set the air controls to the lowest setting Use a wet dry vacuum to pull any remaining water from the system To do this place the vacuum nozzle over each jet starting with the highest jet and fin ishing with the lowest jet 5 Set the air controls to the highest setting and repeat step 3 6 Drain the pumps see DRAINING THE PUMPS on this page Once the water is drained from the pumps place the vacuum nozzle over the drainage hole in the pumps and vacuum any additional water from the pumps Note For additional pro tection remove the pumps motors from the spa and store them in a climate controlled room 7 Clean the spa shell see page 13 Clean the filters see page 13 Shut the power off at the breaker Label the breaker in such a way that the breaker will not be turned on accidentally 10 Re attach the access panel and the spa cover REPLACING THE LIGHT BULB If the underwater light burns out you will need to remove the access panel to replace it see ATTACHING AND REMOVING THE ACCESS PANEL on page 14 Make sure the spa power is turned off Next locate the light housing Turn the light housing counterclockwise and remove it from the spa shell Light Housing eS To replace the light bulb pull the old light bulb
34. tion Rotate the outer ring counterclockwise to turn the jets on Rotate the outer ring clockwise to turn the jets off The three variable flow jets are fully adjustable Turn the outer rings to regulate the flow The power massage jet provides a soothing mas sage to your lower back Turn the outer ring to reg ulate the flow The skimmer cleans the surface of the water Using the Controls Display Air Controls Invert Button 1 2 and 3 Air Control 4 Temperature Buttons Pump Button 1 Pump Button 2 Light Button Air Control 1 Determines the amount of air flowing through the hydrotherapy jets labeled 1 above If the control is turned counterclockwise the amount of air will increase if the control is turned clockwise the amount of air will decrease Air controls 2 4 function in the same manner Air Controls 2 3 and 4 Determine the amount of air flowing through the hydrotherapy jets labeled 2 3 and 4 above Display Invert Button Turns the display 180 allow ing it to be read from inside or outside of the spa Pump Button 1 Turns the spa jet labeled 3 and 4 at the left on and off If the button is pressed once the jet will run providing gentle hydrotherapy If the button is pressed again the jet will shut off 12

Download Pdf Manuals

image

Related Search

Related Contents

BEDIENUNGSANLEITUNG  Frigidaire FGES3065PF Use and Care Manual  03851:バウンサーGIO CAM レッド  Faber 630002752 Ventilation Hood User Manual  Manuale dell`operatore  TE-CD 12 Li  User's Guide  Spectrophotometer AL800/SpectroDirect  Mercedes Benz V klasse 04/2014- Mercedes Benz Vito 11/2014-  LD MEI1000 - Quadrifonia  